You are on page 1of 4

07/2014

GQS , GQV 60 Hz
Submersible Sewage
and Drainage Pumps

Construction
PATENTED Single-impeller submersible pumps, with free-flow (vortex) impeller.
GQS: with vertical threaded delivery port (G 2).
GQV: with horizontal flanged and threaded delivery port
(DN 50 - G 2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.

Applications
For domestic or industrial waste water, dirty water with solids
up to 50 mm grain size, for liquids which are compatible with
the pump materials.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.

Operating conditions
Liquid temperature up to 35 C.
pH value: 6-11.
Maximum immersion depth: 5 m.
Minimum immersion depth: see dimensional table.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 60 Hz (n 3450 rpm).
GQS, GQV: three-phase 220 V;
three-phase 380 V;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
Materials GQSM, GQVM: single-phase 220 V,
with float switch and thermal protector.
Component Material
Incorporated capacitor.
Pump casing Cable: H07RN-F, 3G1 mm2 (3G1,5 mm2 for
Cast iron GJL 200 EN 1561
Impeller GQSM,GQVM 15-15-60), length 10 m, with
Motor jacket plug CEI-UNEL 47166.
Jacket cover Chrome-nickel steel AISI 304 Insulation class F.
Casing cover Protection IP X8 (for continuous immersion)
Handle Polypropylene (with frame in AISI 304) Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
Shaft Chrome-nickel steel AISI 304 EN 60335-1, EN 60335-2-41.
Mechanical seal: upper
Ceramic alumina/Carbon/NBR Other features on request
lower
- Other voltages. - Other mechanical seal. - Cable length 20 m.
Seal lubrication oil Oil for food/pharmaceutical machinery - Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.

Characteristic curves n 3450 rpm


0 Imp. g.p.m. 20 40 60 80 100 120
18

H
GQS, GQV
33
m 50

14 GQS, G ft
QV 50-15-6
0
GQS, 40
12 GQV
50-13
-60
GQS,
10 GQV 50-11-6
0 30
GQS,
GQV
8 50-9-6
0
GQS,
GQV
50-8-
6 60 20

4
10
2

0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600

199
GQS , GQV 60 Hz
Submersible Sewage
and Drainage Pumps

Performance n 3450 rpm


3~ 220V380V 1~ 220V Capacitor P2 m3/h 0 3 6 9 12 15 18 21 24 27 30 33 36
Q
A A IA/IN A Vc IA/IN kW HP l/min 0 50 100 150 200 250 300 350 400 450 500 550 600
GQS 50-8-60 GQSM 50-8-60
3,3 1,9 4 5,5 16 450 3 0,55 0,75 8 7,5 7 6,3 5,6 4,8 4 3 1,8 - - - -
GQV 50-8-60 GQVM 50-8-60
GQS 50-9-60 GQSM 50-9-60
4,1 2,4 3,2 6 16 450 3 0,75 1 9,5 9 8,3 7,7 7 6,2 5,3 4,3 3,2 2,2 - - -
GQV 50-9-60 GQVM 50-9-60
GQS 50-11-60
4,6 2,7 3,9 GQSM 50-11-60 7 25 450 3,3 0,9 1,2 H m 11,3 10,7 10 9,3 8,5 7,5 6,7 5,8 4,5 3,8 2,7 1,5 -
GQV 50-11-60 GQVM 50-11-60
GQS 50-13-60 GQSM 50-13-60
5,6 3,2 4,1 9,6 30 450 5 1,1 1,5 13,3 12,5 11,8 11 10,3 9,5 8,5 7,5 6,5 5,5 4,2 3 1,8
GQV 50-13-60 GQVM 50-13-60
GQS 50-15-60 GQSM 50-15-60
8,7 5 3,2 12,5 35 450 5 1,5 2 15,5 14,8 14 13,3 12,5 11,5 10,5 9,5 8,5 7,4 6,2 4,8 3,5
GQV 50-15-60 GQVM 50-15-60

P2 Rated motor power output. Density = 1000 kg/m3. Kinematic viscosity = max 20 mm2/sec. Tolerances according to UNI EN ISO 9906:2012.
IA/IN = D.O.L.starting current / Rated current.

Dimensions and weights

On On

165

125
G 2 ISO 228
90
130 Off 150 Off
G2

h max
h max

fM

G 2 ISO 228
fM

50
DN 50

h min
h min
145

90

50 M8 19 50

264 242
89
89

94
94

452 430

mm kg mm kg
TYPE TYPE
fM h max h min GQS GQSM fM h max h min GQV GQVM
GQS(M) 50-8-60 460 535 275 14,8 15,8 GQV(M) 50-8-60 460 535 275 15 16
GQS(M) 50-9-60 460 535 275 15 16 GQV(M) 50-9-60 460 535 275 15,2 16,2
GQS(M) 50-11-60 485 560 300 15,8 17,8 GQV(M) 50-11-60 485 560 300 16 18
GQS(M) 50-13-60 505 580 320 18,8 20,3 GQV(M) 50-13-60 505 580 320 19 20,5
GQS 50-15-60 505 580 320 20,3 - GQV 50-15-60 505 580 320 20,5 -
GQSM 50-15-60 535 610 350 - 21,8 GQVM 50-15-60 535 610 350 - 22

200
GQS , GQV 60 Hz
Submersible Sewage
and Drainage Pumps

Installation examples

500 min
284
12
86 161
52

On

3/4"
mm
TYPE h h
max min
Off
h max
G2 ISO 228

GQV(M) 50-8-60 580 320


80 22
GQV(M) 50-9-60 580 320
GQV(M) 50-11-60 605 345
h min

GQV(M) 50-13-60 625 365


176

45
134

GQV 50-15-60 625 365


GQVM 50-15-60 655 395
3.93.037/3

min 500 x 500

430 max

380
138

16
89

360 min
132
100

94

110
166 Pump with threaded ports: Pump with threaded ports: Pump with DN 50 flanged ports:
pipes screwed into the ports pipes with union couplings pipes with counter-flanges
(locally available)

33

3/730.39.3

201
GQS , GQV 60 Hz
Submersible Sewage
and Drainage Pumps

Features
Cable length 10 m, pump single-phase Handle in polypropylene, with frame
with plug PATENTED
in stainless steel.

Easy inspection of the capacitor area.


Easy adjustment of the float switch:
to allow the adjustement of start/stop
pump levels.

Ring against accidental extraction


of the cable.

The double shaft seal with oil cham-


ber separates the motor from the
water and provides further protection
against accidental operation when
Relief valve: the pump is fitted to a dry.
relief valve for air release around the
impeller granting a proper pump pri-
ming also after long standstill periods.

Chamber with food/pharmaceutical


machinery oil

Maximum flexibility of connection:


- Flange DN 50 PN 10 EN 1092-2
- N. 4 M8 holes on 90 for duck Impeller with epoxy cataphoresis
foot coupling SA-G2
treatment for a greater protection
- G 2 ISO 228 against the rust.

Shaft in chrome-nickel stainless steel.

The free-fow impeller (vortex)


costruction is particulary suitable
Pump casing with epoxy cataphore- GQV for liquids containing solids up to
50 mm grain size.
sis treatment joined to the external
paint for a greater protection against
the rust.

G 2 vertical, upward delivery port


for installation in small pits, without
the need for an elbow on the pump.

GQS

202

You might also like