TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
Ambient/stroge temperature 0 ... +50C/-25 ... 70C
Max. Relative humidity 80% Relative humidity for temperatures up to 31C, decreasing linearly to 50% at 40C.
Rated pollution degree According to EN 60529 Front panel : IP65 , Rear panel : IP20
Height Max. 2000m
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply 230V AC +10% -20%, 50/60Hz or 24V AC 10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS
Power consumption Max. 5VA
Wiring 2.5mm screw-terminal connections
While input type in 5A / 60mv ; 0A...9999A ( Determined by c.tr.r parameter. e.g ; If c.tr.r = 5 , scale is 0A...5A )
While input type in CT20/30 / 60mV ;
AC and RMS If ityp = Ct20 , input range is 0A...300A ( Determined by turn parameter. e.g ; If turn = 1 , scale is 0A...300A )
If ityp = Ct30 , input range is 0A...120A ( Determined by turn parameter. e.g ; If turn = 1 , scale is 0A...120A )
Scale
If ityp = 5Hnt , input range is 0A..9999A (Determined by c.tr.r parameter. e.g ; If c.tr.r = 5 , scale is 0A...5A )
While input type in 5A / 60mv ; -999A...9999A ( Determined by c.tr.r parameter. e.g ; If c.tr.r = 5 , scale is -5A...5A )
Frequency Range DC , 10Hz - 200Hz (10Hz - 70Hz For square wave form)
EMC EN 61326-1: 2013
Safety Requirements EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
OUTPUTS
Analog output 0-20mA DC, 4-20mA DC, 0-10V DC or 1-5V DC selection. (Load resistance for current outputs are max. 500)
Alarm output Relay: 250V AC, 8A (for resistive load), NO+NC
Life expectancy for relay Mechanical 30.000.000 ; Electrical 100.000 operation.
HOUSING
Housing type Suitable for flush-panel mounting. (According to DIN 43 700)
Dimensions W77xH35xD61mm
Weight Approx. 250g (after packing)
While cleaning the device, solvents (thinner, gasoline, acid etc.) or corrosive materials must not be used.
TM
ENDA
SSEL MHENDSLK ELEKTRONK SAN. VE TC. A..
erifali Mah. Barbaros Cad. No:18 Y.Dudullu 34775
MRANYE/STANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
1/4 EPA242-E-03-161212
DIMENSIONS OUTPUT CHART
For removing mounting clamps : Input
Depth
77mm - Push the flush-mounting
61mm 5mm
clamp in direction 1 as
UP.l1
OUT AC DC ACDC shown in the figure left.
- Then, pull out the clamp in UP.l1 + HYS.U
35mm
A direction 2.
0.000 SET
Note : LO.l1 + HYS.L
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument A.out = n.c.
and it should be easily accessible by the operator.
t
Fuse should be connected. Cable size: 1,5mm
0 A 1 0.000 A 1
ENDA EPA242 is intended for installation in control panels. Make sure that the device is used only for intended purpose.The electrical T/2 T 3T/2 2T
2 2
connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. During an -A
installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations and severe soiling. Make sure that the operation temperature is not exceeded. The cables should not A
be close to the power cables or components.
0.308 A A 2 A 1
CAUTION : 0
T/2 T 3T/2 2T p 2
If 5A / CT20-30 and 60mV inputs are connected at the same time, the measurement will be incorrect.
A
ENDA INDUSTRIAL ELECTRONICS ENDA INDUSTRIAL ELECTRONICS ENDA INDUSTRIAL ELECTRONICS
A1
SN: XXXXXXXXX SN: XXXXXXXXX
A 1
SN: XXXXXXXXX
EPA242-R-230VAC-RSI EPA242-230VAC-RSI EPA242-A-230VAC-RSI 0.386 A
PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE 0
T/2 T 3T/2 p 2
AC/DC AMMETER
8 680407 704330 AC/DC AMMETER
8 680407 704316 AC/DC AMMETER
8 680407 704330
CAT II Made in Turkey CAT II Made in Turkey CAT II Made in Turkey
ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX ENDA INDUSTRIAL ELECTRONICS SN: XXXXXXXXX A
A 1 A 1 A 1
EPA242-230VAC EPA242-CT-A-230VAC EPA242-CT-R-230VAC-RSI
PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE
AC/DC AMMETER
8 680407 704309 AC/DC AMMETER
8 680407 704323 AC/DC AMMETER
8 680407 704323 0
T/2 T 3T/2 2T
2 2 2
CAT II Made in Turkey CAT II Made in Turkey CAT II Made in Turkey
CT20 CT30 0
T/2 T 3T/2 2T
A 1 0.000 A 1
CCt20
T20 CCt20
T30
20 3 3
-A
2/4 EPA242-E-03-161212
PROGRAMMING DIAGRAM
OUT AC DC ACDC
Increment Used for increasing the setpoint value and changing parameters. LOCKING & UNLOCKING KEYPAD
key When held down for a few seconds, configured numeric value increases faster.
A
Measured Value Measured Value
SET SET
& &
Day.Month
01.01 2015
Year Measured Value
0.00
SET
& &
& If these keys are pressed and held together, revision
&
parameter cant be lower than If key is pressed, the current value of the parameter appears by flashing on the display.
( l0ll - HY5U - HY5L )
Decimal Indicator By using UP or DOWN navigation keys, selected parameter can be adjusted to
d.pnt If measured value is lower than 10, it can be shown as
(0.000) , (0.00) , (0.0) or (0).
the desired value.
Hysteresis Value for Upper Limit SET
If measured value between 10 and 100, it can be shown as After the setting up the parameters, if set key is pressed again, adjusted parameter
(0.00) ,(0.0) or (0). HYSU It can be adjusted between 0 and ctrr /5
name appears on display.
If measured value between 100 and 1000, it can be shown as parameter. This parameter cant be higher than
(0.0) or (0) . ( Upll - l0ll - HY5L ).
Decimal point moves automatically according to displayed value on When ctrr changed, HY5U gets the value DEFAULT SETTINGS
the screen. of 0.1 . Powered on device by pressing key. dPAr message appears
Delay Time for Upper Limit Alarm on display and device reset to default settings.
Samping Time
Opnt If 1 ( 1 ) is selected ; sampling time of the measurement is 250ms, dLYU It can be adjusted between 0 and 900 .
If 2 ( 2 ) is selected, it is 500ms. If 3 ( 3 ) is selected, it is 750ms. ERROR MESSAGES
If 4 ( 4 ) is selected, it is 1 second.
Measured current value is higher than maximum scale.
Device Address
Lower Limit Value
Adr5 It can be adjusted between 1 - 247 . LOLL It can be adjusted between lower scale and upper
scale that is specified with c.tr.r parameter. Measured current value is lower than minimum scale.
This parameter cant be higher than ( UPLL -
HY5U - HY5L) value.
Baud Rate
CT20/30 Current Transformer & Windings Chart
bAUd It can be adjusted as OFF, 1200, 2400, 4800, 9600, 19200,
Hysteresis Value for Lower Limit
38400, 57600 and 115200 .
HYSL It can be adjusted between 0 and Ctrr /5 . This turn 1 2 3 4 5 6 7 8 9 10
parameter cant be higher than ( UPLL - L0LL - CT20 Iin max(A) 300 150 100 75 60 50 42,8 37,5 33,3 30
HY5U ) value. When ctrr is changed, HY5U
Input Type ( In devices with input type "CT" ) CT30 Iin max(A) 120 60 40 30 24 20 17,1 15 13,3 12
gets the value of 0.1 .
ityP Can be adjusted to Ct20 , CT30 and 5HNt values.
If 5Hnt is selected, 60mV input terminal must be used. Delay Time for Lower Limit Alarm
dLyL It can be adjusted between 0 and 900 seconds. Note :
Number of Windings ( In devices with input type "CT" ) If ityp = 5hnt , turn parameter is not appears.
Number of windings of the current cable getting through the CT20/30 If ityp = Ct20 or Ct30 , ctrr parameter is not appears.
turn current transformer.
Please see "CT20/30 Current Transformer & Windings" chart on Delay Time for Initial Upper Limit Alarm Note :
the right of this page. Before setting the relay parameters, the operating scale must be
5dly It can be adjusted between 0 and 900 seconds.
determined from dpnt parameter.
Analog Output Status ( In devices with output type "Analog" )
Can be adjusted to 0 - 20 , 4 -20 , 0 -10 and 1 - 5 values. If dpnt , typE and Ityp parameters are changed, Upll ,
AtyP loll , Hy5U and Hy5l values must be checked.
3/4 EPA242-E-03-161212
ENDA EPA242 DIGITAL AMPERMETER MODBUS PROTOCOL ADDRESS MAP
HOLDING REGISTERS FOR R EXTENSION DEVICES
Holding Register
Addresses Data Data Content Parameter Read/Write Status
Type Name Permission Value
Decimal Hex
0000d 0x0000 word OUT1 output status 0tyP Read / Write no
0001d 0x0001 word Current conversion ratio ctrr Read / Write 5
0002d 0x0002 word The upper limit of the setpoint UPLL Read / Write 5.00
0003d 0x0003 word The upper limit of the hysteresis value HY5U Read / Write 0.10
0004d 0x0004 word Delay time for the upper limit alarm dlyU Read / Write 0
0005d 0x0005 word The lower limit of the setpoint L0Ll Read / Write 0.00
0006d 0x0006 word The lower limit of the hysteresis value HY5L Read / Write 0.10
0007d 0x0007 word Delay time for the lower limit alarm dLyl Read / Write 0
0008d 0x0008 word Measurement method (0=AC, 1=DC, 2=ACDC) typE Read / Write aCdC
0009d 0x0009 word Decimal point. (0 = 0 , 1 = 0.0 , 2 = 0.00 , 3 = 0.000) dpnt Read / Write 0.00
Sampling time of the measurement value. If 1 is selected, it is
0010d 0x000A word 250ms. If 2 is selected, it is 500ms. If 3 is selected, it is 750ms. OPTN Read / Write 4
If 4 is selected, it is 1 second.
Device address for RS485 network connection. aDr5 1
0011d 0x000B word Read / Write
Adjustable between 1-247.
Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200 Read / Write
0012d 0x000C word 6= 38400; 7= 57600; 8= 115200) BAUD oFF
0013d 0x000D word Delay Time for Initial Upper Limit Alarm 5dly Read / Write 0
* 0014d 0x000E word Input type (0=Ct20, 1=Ct30, 2=5Hnt) ityp Read / Write ct20
* 0015d 0x000F word Number of windings for transformer turn Read / Write 1
* 14 and 15 Addresses are used only in devices with input type CT20/30.
Holding Register Parameter Table (For devices with No Relay and A type output models)
0000d 0x0000 word Current conversion ratio ctrr Read / Write 5
0001d 0x0001 word Measurement method (0=AC, 1=DC, 2=ACDC) typE Read / Write aCdC
0002d 0x0002 word Decimal point. (0 = 0 , 1 = 0.0 , 2 = 0.00 , 3 = 0.000) dpnt Read / Write 0.00
0003d 0x0003 word Sampling time of the measurement value 0PTN Read / Write 4
0x0004 word Device address for RS485 network connection.
0004d aDr5 Read / Write 1
Adjustable between 1-247.
Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200 Read / Write
0005d 0x0005 word BAUD 9600
6= 38400; 7= 57600; 8= 115200)
* 0006d 0x0006 word Input type (0=Ct20, 1=Ct30, 2=5Hnt) ityp Read / Write ct20
* 0007d 0x0007 word Number of windings for transformer turn Read / Write 1
** 0008d 0x0008 word Analog output type (0=0-20 , 1=4-20 , 2= 0-10 ,3=1-5) Atyp Read / Write 0 - 20
* 6 and 7 Addresses are used only in devices with input type CT20/30.
** 8 Address is used only in devices with output type A.
In devices with input type CT20/30, following parameter settings will change automatically if the ityp parameter is changed.
If ityp = Ct20 ; UpLL = 300.0 , LoLL = 0 , Hy5U = 0.10 , Hy5L = 0.10
If ityp = Ct30 ; UpLL = 120.0 , LoLL = 0 , Hy5U = 0.10 , Hy5L = 0.10
INPUT REGISTERS FOR R EXTENSION DEVICES
Input Register
Addresses Data Data Content Parameter
Name Read/Write Permission
Decimal Hex Type
TM
ENDA
SSEL MHENDSLK ELEKTRONK SAN. VE TC. A..
erifali Mah. Barbaros Cad. No:18 Y.Dudullu 34775
MRANYE/STANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
4/4 EPA242-E-03-161212