Professional Documents
Culture Documents
UCI224F
SPECIFICATIONS & OPTIONS
MX321 AVR
The most sophisticated of all our AVRs combines all the NB Continuous development of our products entitles us
features of the MX341 with, additionally, three-phase to change specification details without notice, therefore
rms sensing, for improved regulation and performance. they must not be regarded as binding.
Over voltage protection is built-in and short circuit
current level adjustments is an optional facility. Front cover drawing typical of product range.
2
UCI224F
WINDING 311
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX321 MX341
VOLTAGE REGULATION 0.5 % 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)
3
UCI224F
50 Winding 311
Hz THREE PHASE EFFICIENCY CURVES
4
UCI224F
60 Winding 311
Hz THREE PHASE EFFICIENCY CURVES
5
UCI224F
Winding 311
50
Hz
MX SX
346V 380V 400V 415V 440V 346V 380V 400V 415V 440V
30 30
25 25
P ER C EN T T R A N S IE N T V O L T A G E D IP
P ER C EN T T R A N S IE N T V O L T A G E D IP
20 20
15 15
10 10
5 5
0 0
0 50 100 150 200 250 0 20 40 60 80 100 120 140 160 180 200
LOCKED ROTOR kVA LOCKED ROTOR kVA
60
Hz
MX SX
380V 416V 440V 460V 480V 380V 416V 440V 460V 480V
30 30
25 25
P E R C E N T T R A N S IE N T V O L T A G E D IP
P ER C EN T T R A N S IE N T V O L T A G E D IP
20 20
15 15
10 10
5 5
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250
LOCKED ROTOR kVA LOCKED ROTOR kVA
6
UCI224F
Hz
SYMMETRICAL
ASYMMETRICAL
1000
CURRENT (Amps)
100
10
0.001 0.01 0.1 1 10
TIME (secs)
60 10000
Hz
SYMMETRICAL
ASYMMETRICAL
CURRENT (Amps)
1000
100
0.001 0.01 0.1 1 10
TIME (secs)
RATINGS
Class - Temp Rise Cont. F - 105/40C Cont. H - 125/40C Standby - 150/40C Standby - 163/27C
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
50 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Hz Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254
kVA 65.0 65.0 65.0 48.7 72.5 72.5 72.5 55.0 77.0 77.0 77.0 58.0 80.0 80.0 80.0 60.5
kW 52.0 52.0 52.0 39.0 58.0 58.0 58.0 44.0 61.6 61.6 61.6 46.4 64.0 64.0 64.0 48.4
Efficiency (%) 90.0 90.3 90.4 90.7 89.6 89.9 90.1 90.4 89.4 89.7 89.9 90.3 89.2 89.6 89.8 90.2
kW Input 57.8 57.6 57.5 54.7 64.7 64.5 64.4 61.9 68.9 68.7 68.5 65.6 71.7 71.4 71.3 68.3
Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
60
Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240
Hz
Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277
kVA 75.0 78.1 78.1 82.5 83.8 87.5 87.5 93.8 88.8 92.5 92.5 100.0 91.9 95.0 95.0 102.5
kW 60.0 62.5 62.5 66.0 67.0 70.0 70.0 75.0 71.0 74.0 74.0 80.0 73.5 76.0 76.0 82.0
Efficiency (%) 90.5 90.7 90.9 91.0 90.0 90.3 90.6 90.6 89.8 90.1 90.4 90.4 89.6 89.9 90.3 90.3
kW Input 66.3 68.9 68.7 72.5 74.5 77.5 77.3 82.8 79.1 82.1 81.9 88.5 82.1 84.5 84.2 90.8