You are on page 1of 10

EA890

EA8900 series
10 - 120 kVA

The EA8900 offers high performance and three phase uninterruptible


power for data centre and critical environments which demand maximum
uptime without interruption.
Table of contents

5 Introduction

8 Reliability

10 LCD Display

11 Batteries

12 Battery Monitoring
EA8900 series 13 Services
10 - 120 kVA 14 Control

16 Weight and dimensions

18 Technical data sheet EA8900


Introduction
The EA8900 provides a solid foundation for todays high availability equipment,
giving users critical and clean power, 24/7, without interruptions.

The cost effective EA8900 UPS systems are equipped with advanced features
such as true online double conversion technology, a user friendly touch screen
display, generator compatibility, and optional control through the network.
With its wholly reliable performance, EA8900 solutions are widely deployable,
making them the answer to all of your high performance demands.

True Online Double Conversion

The EA8900 applies true online double


conversion technology, providing users with
clean and high quality power. The zero transfer
time ensures that power is supplied without
interruption, thereby fully protecting mission-
critical devices.

Where will you be when the lights go out?


Wide Input Voltage Range

The EA8900 provides stable power to


connected devices in unstable power
conditions. It is capable of handling a wide
input voltage range, supplying clean power in
extreme circumstances.

Pure Sine-wave

The pure sine-wave output of the EA8900


guarantees compatibility with various
applications, including those that are high Front view of the EA8900 15kVA
performance, industrial, or mission critical.

The true online double conversion technology overview

4 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 5


Self-diagnosis at UPS Start Up

The UPS will perform advanced self-diagnostics


to ensure the functionality of the UPS system
and batteries, and to anticipate events before
they occur.

IGBT

The Insulated Gate Bipolar Transistor (IGBT) is a Fans on the back of the EA8900 10kVA
power semiconductor device for high efficiency
and fast switching, providing more reliable, clean
and high efficiency power to the UPS, which is
critical when using electrical equipment. Short Circuit and Overload
Protection

Cold Start A short circuit is an abnormal connection


between two nodes of an electrical circuit, and
In the absence of any AC input, the cold start can cause huge damage to the UPS and any
function allows users to start the UPS with the equipment attached to it. The EA8900 circuit
batteries, and without any damage to them or protection device will protect against potential
the circuits. This means that users can easily short circuit damage, overheating, fire, or even
configure the UPS, even if no AC input is explosions. The UPS is also equipped with
connected. overload protection, meaning that the fuse will
automatically be triggered when a load exceeds
its value. Both protection devices ensure
Lightning and Surge Protection the safety and reliability of the UPS and any
equipment that is attached to it.
The EA8900 UPS systems come with lightning
and surge protection as standard, thus
protecting the equipment against voltage spikes. EMI RFI Noise Filter
Surge protection works by channeling the
The front view of the EA8900 60 and 160kVA UPS extra voltage into the outlets groundning wire, Electromagnetic interference (EMI or radio
preventing it from flowing through electronic frequency interface, RFI) is a disturbance which
devices, while also allowing normal voltage to affects an electrical circuit. The EMI RFI Noise
be maintained. Filter will protect the UPS system against any
interference which may interrupt the effective
Optional Emergency Power Off performance of the device.
(EPO) Function Variable Fan Speed

The EA8900 is equipped with an Emergency The intelligent variable fan speed ensures that
Power Off function, providing users with a way of the speed of the fans is adjusted to the amount
immediately shutting down all output power from of load and heat dissipation of the UPS.
the UPS in the case of emergencies such as fire,
flood, and overheating equipment.

6 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 7


Reliability

In todays business environment, it is important to have a power infrastructure


available 24/7. The EA8900 is extremely reliable through the redundant design
of the internal components.

Manual Bypass Switch

Maintenance work can be carried out through


the use of the manual bypass switch. This com-
pletely isolates the UPSs internal components,
so that minor maintenance work and repairs can
be conducted without interruption to supply.

Optional External Bypass Switch

The external bypass switch ensures that there is


continuous power to the equipment by com-
pletely isolating the UPS bridging between it and
the mains. Using this tool, users have the ability
to carry out substantial interventions and even
change a UPS without interruption to supply.

Front side of the EA890 10kVA


AC Generator

Input
Bypass
UPS BAT UPS BAT BYPASS
Automatic Bypass Switch 1 1 1 1

The EA8900 is also equipped with automatic The automatic bypass will switch the input from
and manual transfer switches as standard, the mains directly to the output of the UPS in
Output
guaranteeing that power will be supplied to the the event of overloading or failure of the system.
load and, therefore, the equipment, even during This guarantees continuous power to the output
Load
maintenance. without interruption.

8 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 9


LCD Display Batteries

The LCD display combines functionality with the provision of instant access The need to have reliable batteries is extremely important. EAST has years
to details of all of a systems conditions and statuses, meaning that valuable of experience in the design and manufacturing of high quality batteries and
critical data is always at an operators finger tips. through the use of the latest charging and discharging technologies you are
assured that they keep supplying that critical power.

Advanced Battery Management Extended Runtime

The EA8900 UPS systems are equipped with a By adding one or more battery cabinets to the
sophisticated three step charger for efficiently configuration, it is easy to increase the runtime
charging the UPS while prolonging battery life. of the system from several minutes up to several
hours, creating a custom solution which will meet
users varied business demands.

Charge
Voltage (V)

Charge
Current (A)

90% 100% Capacity

Step 1
The charger provides a constant charge current
until the battery has reached 80% of its capacity,
meaning that the UPS is ready to operate again
Sealed Lead Acid batteries providing power to the EA8900
when a new power failure occurs. in case of a power failure

The LCD display displaying all relevant information Step 2


The charge voltage is held constant for about 60 Batteries
minutes, allowing the charge current to gradually
decline towards the end of this period. The The batteries are Valve-Regulated Maintenance
Touch screen LCD display Users can view major system values and battery will now have been charged to about Free Sealed Lead-Acid, and utilize state of the
conditions: 90% of its capacity. art Oxygen Recombination technology. EAST has
The UPS is equipped with an LCD touch screen several years of experience in the design and
display, meaning that it is easy to manage. UPS information Step 3 manufacturing of high quality NP series batteries.
Information such as operational status and Input The charge voltage drops to a float-charge in Their fully sealed structure, long life, reliability
procedures, measurements, values, and failure Output order to compensate for self discharge, thereby and quality make them more convenient to use
records will all be displayed. Load information prolonging the life of the batteries. and the solution to the significant demands of
Battery todays business environment.
History
Settings The EA8900 is equipped with an automatic and
System diagnostics manual transfer switch as standard, guaranteeing
that power is supplied to the load, even during
maintenance procedures.

10 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 11


Battery Monitoring Installation Services

Features: BAT monitoring device (BMD) Start Up Service Going Live Service

Completely maintenance-free By letting an EAST certified engineer conduct This is an extra feature which includes having
Leakage proof your installation, you are certain to save both an EAST certified engineer present on site at
BMD
Safe, flame-protected time and money. With our professional approach the time when your configuration goes live. This
Low inner resistance; an excellent discharge and knowledge, we will install all of your EAST means that there is both an extra helping hand
in the case of a large current products, thereby ensuring their safety and available if something need to be explaned and
Long life; 3-5 years for the NP series lifespan. The start up service includes the on an extra quality check of the installation.
Wide operating temperature BM BM BM BAT module (BM) site installation and commisioning of your UPS
No dissociated electrolyte; position systems and batteries, with the guarantee that
independent the products will function according to EAST

Maintenance
Low self-discharge BAT BAT BAT standards.
Unique engineering design; good recovery

Services
capability from deep discharge As a unique feature, EAST has included the
Optional 12 year gel batteries are available Batteries installation of its licence free software in the start
up service. EAST will perform on site installation
and intergration of all EAST software.
Schematic overview of the battery monitoring system
Preventive Maintenance

Once your confirguration is operational and


active, you want to be confident that its
performance is as efficient as possible.
The unique EAST BAT system provides the To ensure the life of the batteries and UPS
operator with in-depth knowledge and control of system, we offer a preventive maintenance
the batteries connected to the EA8900. The BAT service whereby an EAST certified engineer will
system guarantees optimal capacity and runtime come on site to check all of your EAST products.
throughout the life of the battery, ensuring that During this process, the engineer will run several
there is no loss of investment due to faulty bat- tests and carry out any maintenance work when
teries. required to do so.

The system monitors the charge and discharge Extra Service Support
current, temperature, and quality of each indi-
vidual battery, ensuring a constant and reliable The standard service support may not always
power supply to the UPS. Each individual battery meet your needs, and in these circumstances
is monitored through the BAT module, which is you can extend the help available to you by
connected to the positive and negative poles of taking out one of our extra service support
the battery. This module tests and monitors the packages.
battery and relays all relevant information to the
BAT monitoring device. These come in two different sizes:

The operator can monitor and set predetermined 1) 9x5: five days a week, nine hours a day
thresholds in the system through the user-friend- 2) 24x7: seven days a week, 24 hours a day
ly web interface or the LCD display positioned on
the side of the battery cabinets.The system can During the hours that support is available to you,
also be fully integrated with a building manage- the services on offer include full assistance via
ment system through the use of the industry The service engineers of EAST Power a customer help-line and email, next day on site
The 60 kVA EA8900 with fully digital control standard SNMP protocol for communication. are available 24/7 to assist you. repair or replacement, and a response time of
four hours.

12 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 13


Control

RS232 + Dry contact M  onitoring and management of the EA8900


using a standard web browser or SNMPview
The EA8900 is equipped with a multifunctional capable of monitoring up to 1000 pieces in one
RS232 port. This can be used for dry contact, view
supplying relay functionality for a low battery,  Remote control and rebooting of UPS-
AC fail, and other common failures of custom- protected devices over the network
wired applications. It can also be connected to  Using the licence free software, protection
a computer or server for the standard shutdown of user information through the automatic
software. shutdown of multiple UPS-protected devices
during an extended power failure
Real-time email alarm notification
Standard Shutdown Software  Real-time SMS alarm notification with SMS
server software (additional hardware required)
The EA8900 is able to automatically shut down  Supports standard UPS MIB for third-party
the server or computer when a power failure network management software
occurs. This software enables the UPS to instruct Multi language web interface
the operating systems to close down a PC  PDA/WAP interface for management through
when it is running unattended. Users can set the the internet or network when users are on the
parameters with which to schedule the computer move
or server to shutdown, making sure that no Client software is licence free, with no
significant data is lost and important backups are additional fees, and is available for Windows,
created. Updates will be automatically sent by Linux Back of the EA8900 10kVA
email, so that users are always aware of what is
happening, even at remote locations.
Environmental Card GPRS Card

Communication Slot The environmental card provides the functionality The GPRS card can be used with the EA8900
with which to remotely monitor environmental and enables the user to have an in depth
The multifunctional communication slot is and UPS conditions using a standard web overview of the status of the UPS and the power
conveniently located at the back of the UPS browser, SNMPview, or third-party network at a particular location without any network or
and can be used to accommodate a variety of Intergration with the Building Management System management software. Users can observe the internet connection. The status can be viewed
accessory cards. The wide range of cards that ambient temperature, humidity, or the presence using the web interface, SNMPview or third-party
are available means that the EA8900 can be of water in the remote location, along with the network management software. As long as there
used for various applications and in numerous status of additional contact devices such as a is GPRS coverage, users will be able to deploy
locations. SNMP Card smoke detector or an open-door/window sensor. this card.

The SNMP card allows users to connect the


EA8900 directly to the ethernet network and Relay I/O Card USPs
the internet. This solution means that users can
conveniently monitor and manage the UPS with The Relay I/O card can be inserted in the SNMP Software license free
a standard web browser, while simultaneously slot at the back of the UPS, providing dry contact Monitor 1000 UPS systems in a single view
being able to shutdown multiple computers and relay outputs for custom-wired applications and Diversity of Operating Systems supported
operating systems over the network. delivering support for the built-in shutdown of Integrate with your Building Management
AS/400 systems. This option provides contact System or Network Management System

HTTP, SNMP, SMTP, WAP, Telnet, SSL, SSH, closures for the remote monitoring of alarm Real-time email and SMS alarm notification
SNMPV3, Radius, and MODBUS on TCP/IP conditions in the UPS, delivering signals for On Monitor suroundings in real-time via
compatibility; dynamic and versatile support Battery, On Bypass, Low Battery, Summary environmental sensors
The EA-SNMP internal communication card for a wide variety of system configurations Alarm, UPS Fault and On UPS.

14 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 15


Technical data sheet EA8900 (10-120 kVA)
EAST Power N.V. technical data sheet EA8900 [True Online Double Conversion 10 - 120 kVA] EAST Power N.V. technical data sheet EA8900 [True Online Double Conversion 10 - 120 kVA]
Model EA8910 EA8915 EA8920 EA8930 EA8940 Model EA8960 EA8980 EA89100 EA89120
kVA Rating 10 kVA 15 kVA 20 kVA 30 kVA 40 kVA kVA Rating 60 kVA 80 kVA 100 kVA 120 kVA
Real Power Rating: 8.000 Watt 12.000 Watt 16.000 Watt 24.000 Watt 32.000 Watt Real Power Rating: 48.000 Watt 64.000 Watt 80.000 Watt 96.000 Watt
AC INPUT AC INPUT
Phase 3 Phases + N + G Phase 3 Phases + N + G
Voltage 380V/400V/415V 25% Voltage 380V/400V/415V 25%
Frequency 50/60Hz 5% Frequency 50/60Hz 5% 40 ~ 65Hz
Power Factor 0.85 [0.92 using optional input filter] Power Factor 0.85 [0.92 using optional input filter]
Soft Start 0 ~ 100% 5s Soft Start 0 ~ 100% 5s
BYPASS INPUT BYPASS INPUT
Phase 3 Phases + N + G Phase 3 Phases + N + G
Voltage 380V/400V/415V 25% Voltage 380V/400V/415V 25%
Frequency 50/60Hz 5% Frequency 50/60Hz 5% 50/60Hz [5% or 10% adjustable]
Transfer Time 0ms, Inverter/Bypass [Overload] Transfer Time 0ms, Inverter/Bypass [Overload]
DC SYSTEM DC SYSTEM
Voltage 360V [Rated Voltage] Voltage 360V [Rated Voltage] 348V [Rated Voltage]
Current 28 A 42 A 56 A 85 A 113 A Current 169 A 200 A 254 A 304 A
Charge Current 1 ~ 50A [Adjustable depending on batteries] Charge Current 1 ~ 50A [Adjustable
5 ~ 20A [Adjustable depending on batteries]
depending on batteries]
AC OUTPUT
AC OUTPUT
Phase 3 Phases + N + G
Phase 3 Phases + N + G
Voltage 380V 1% [Stable Load]; 380V 5% [Fluctuated Load]
Voltage 380V 1% [Stable
Frequency 50 ~ 60Hz 0.5% [Battery Mode] Load]; 380V 5% 380V2%[Stable Load],380V2%[Fluctuated Load]
Power Factor 0.8 [Fluctuated Load]

Wave Form True Sine Wave Frequency 50 ~ 60Hz 0.5% 50 ~ 60Hz 1% [Battery Mode]
[Battery Mode]
THDi Total Harmonic Distortion 3% [Linear Load]; 5% [Non-Linear Load]
Power Factor 0.8
Dynamic Response Time Dynamic Respons Recovery Time 10ms
Wave Form True Sine Wave
Overload 125% for 10 minutes; 150% for 1 minute
THDi Total Harmonic Distortion 3% [Linear Load]; 5% [Non-Linear Load]
Cooling Forced Air [Load depended]
Dynamic Response Time Dynamic Respons Recovery Time 10ms
PANEL DISPLAY
Overload 125% for 10 minutes; 150% for 1 minute
LCD/LED User Friendly interface via touch screen LCD display; Load/Battery capacity; Online; battery status;
overload etc. Cooling Forced Air [Load depended]

GENERAL PANEL DISPLAY

Efficiency 91% LCD/LED User Friendly interface via touch screen LCD display; Load/Battery capacity; Online; battery status;
overload etc.
Communication RS232; [Optional SNMP & Dry Contact]
GENERAL
Noise 48 ~ 60db 53 ~ 65db
Efficiency 91%
Temperature 0 ~ 40 C [Operating]
Communication RS232; [Optional SNMP & Dry Contact]
Humidity 30 ~ 90% [non-condensing]
Noise 53 ~ 65db 55 ~ 65db
Isolation Transformer
Temperature 0 ~ 40 C [Operating]
Optional Harmonic Suppression Filter
Humidity 30 ~ 90% [non-condensing]
Parallel Function
Isolation Transformer
Dimension [mm]
1140 x 450 x 725 1230 x 450 x 850 Optional Harmonic Suppression Filter
[H x W x D]
Net Weight [Kg] 208 220 240 316 334 Parallel Function
Packing Dimension [mm] Dimension [mm] [H x W x D] 1500 x 710 x 850 1700 x 1200 x 900
1310 x 556 x 828 1395 x 565 x 945
[H x W x D]
Net Weight [Kg] 650 900 950 1050
Gross Weight [Kg] 232 248 265 346 364 Packing Dimension [mm]
1662 x 810 x 945 1850 x 1300 x 1000
Product Specifications are subject to change without further notice, EAST Power N.V. [H x W x D]
Gross Weight [Kg] 695 965 1015 1115
Product Specifications are subject to change without further notice, EAST Power N.V.

18 EA8900 SERIES / www.eastpwr.com EA8900 SERIES / www.eastpwr.com 19


EAST Power N.V. EAST ups middle east trading fze EAST Power France/Africa

Weiland 1C P.O. Box 10559 197, Avenue des Grsillons


6666 MH, Heteren Ras Al Khaimah 92230 Gennevilliers
The Netherlands United Arab Emirates France

T +31 (0) 26 47 90 790 T +971 (0) 7 2 076 609 T +33 (0) 18 28 85 551
F +31 (0) 26 47 43 704 F +971 (0) 7 2 041 010 F +33 (0) 97 21 64 530

www.eastpwr.com www.eastpwr.com www.eastpwr.com

You might also like