DIMENSIONS SETTING

50 EASY TOUCH
The sensor uses the patent-covered EASY TOUCH technology that
42 15 allows a rapid and safe self-setting of the product.
Two different setting possibilities are available:

2
- EASY TOUCH; a long pressure of the SET pushbutton allows self-
setting.
- FINE DETECTION; to be used only in particularly critical conditions.
This setting procedure is used only when the EASY TOUCH is not

S60W sufficient.

42
50
S60W setting

29.5
Contrast sensor

18x45
To achieve a correct sensor functioning, the coloured mark or object to
be detected has to be placed at the right reading distance.
- EASY TOUCH (standard detection in the DARK mode)
The EASY TOUCH technology allows the functioning in the DARK
INSTRUCTION MANUAL

16
mode (mark presents a lower light intensity respect to the
background).
The mark to detect has to be placed correctly at the right reading
distance within the sensor spot.
11 6 14 M12 Press the SET pushbutton until the READY/ERROR LED turns off.
CONTROLS Release the SET pushbutton and wait for the READY/ERROR LED to
turn green.
OUTPUT LED 15 The sensor is now ready to detect the pre-set coloured mark or object
The yellow LED ON indicates that the N.O. (normally open) output (output LED turns on when the N.O. output is closed).
status is closed. 23.6 CABLE VERSION - Fine detection (DARK or LIGHT mode)
READY/ERROR LED (bicolour) READY/ERROR LED This mode offers an improved detection precision. The sensor can
When the bicoloured LED is continuously green, the sensor is operating function either in the DARK operating or in the LIGHT operating mode
in a normal condition and it is ready to function correctly (stability (light-coloured mark on dark background).
condition). OUTPUT LED The operating mode is selected automatically by the sensor.

4
The red and green blinking of the LED indicates a wrong sensor setting. The mark to detect has to be placed correctly at the right reading
Please refer to the SETTING paragraph to get the correct setting distance within the sensor spot.
procedure. SET PUSH-BUTTON mm Press the SET pushbutton. The READY/ERROR LED turns off. Keep
the SET pushbutton pressed until the READY/ERROR LED blinks
SET PUSHBUTTON
green. Place the background under the sensor spot.
A long pressure on the pushbutton activates the self-setting procedure.
Press the SET pushbutton again until the READY/ERROR LED turns
The REMOTE input allows the external control of the SET pushbutton. TECHNICAL DATA off.
The sensor is now ready to detect, with a very high precision, the pre-
Power supply: 10 30 Vdc (limit values)
set coloured mark (output LED turns on, READY/ERROR LED turns
Ripple: 2 Vpp max. green).
INSTALLATION Current consumption
30 mA max. The output LED is ON and the N.O. output is closed, when the sensor
(output current excluded): is positioned on the pre-set coloured mark.
The sensor can be positioned by means of the three housings holes Outputs: PNP or NPN; 30 Vdc max. (short-circuit protection)
using two screws (M4x25 or longer, 1.5 Nm maximum tightening torque)
with washers.
Output current: 100 mA REMOTE FUNCTION
Output saturation voltage: 2V
Various orientable fixing brackets to The REMOTE wire, if connected to +Vdc, is equal to the pressure of the
ease the sensor positioning are
Response time: 100 s max.
Switching frequency: 5 KHz SET button. If the REMOTE wire is connected to +Vdc, when the sensor
available (please refer to the is powered ON, the keyboard lock function is activated; the SET button
accessories listed in the general Indicators: OUTPUT LED (YELLOW) / READY/ERROR LED (GREEN/RED)
is no longer active. To deactivate the keyboard lock function, the sensor
catalogue). Setting: SET pushbutton has to be turned off and powered again with the REMOTE wire not
The operating distance is measured Data retention: non volatile EEPROM memory connected or connected to 0V.
from the front surface of the sensor Operating temperature: -10 55 C
optics. Storage temperature: -20 70 C
The M12 connector can be oriented Electrical shock protection: Class 2
at two different positions using the DECLARATION OF CONFORMITY
specific fastening spring and rotating
Operating distance (typical values): 19 mm 2 mm We DATALOGIC AUTOMATION declare under our sole responsibility
the block of 180. Minimum spot dimension: 3.5 mm at 19 mm that these products are conform to the 2004/108/CE and successive
Emission type: white light LED (400-700nm) amendments.
Ambient light rejection: according to EN 60947-5-2 WARRANTY
CONNECTIONS Vibrations: 0.5 mm amplitude, 10 55 Hz frequency, for every axis (EN60068-2-6) DATALOGIC AUTOMATION warrants its products to be free from
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) defects.
DARK/LIGHT selection: DARK mode with EASY TOUCH / Automatic with fine detection DATALOGIC AUTOMATION will repair or replace, free of charge, any
BROWN M12 CONNECTOR Housing: ABS product found to be defective during the warranty period of 36 months
+ 10 30 Vdc
from the manufacturing date.
Lens: glass window (sloped); glass lens
WHITE This warranty does not cover damage or liability deriving from the
Mechanical protection: IP67
REMOTE * REMOTE *
(WHITE)
2 1 + 10 30 Vdc Connections: 2 m cable 4 mm / M12-4 pole connector
improper application of DATALOGIC AUTOMATION products.
(BROWN)
BLACK Weight: 90 g. max. cable vers. / 40 g. max. connector vers.
N.O. OUTPUT 3 4
0 V- N.O. OUTPUT
BLUE (BLUE) (BLACK)
0V
DELAY FUNCTION
* = Connect the REMOTE wire to 0 V if not used. Press the SET pushbutton and keep it pressed until the READY/ERROR LED turns off, blinking and turns off again, then release the SET DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and
pushbutton. improvements without prior notification.
NOTE If the delay function is not active the READY/ERROR LED blinks green with 2 quick pulses. Datalogic and the Datalogic logo are registered trademarks of Datalogic
If a setting error will occur please repeat again the EASY TOUCH If the delay function is active the READY/ERROR LED blinks green with 4 quick pulses. S.p.A. in many countries, including the U.S.A. and the E.U.
setting procedure, in order to be sure to restart the setting procedure Press and release immediately the SET pushbutton in order to change the function status, the new function status is indicated the
correctly. READY/ERROR LED as the mode before described. The delay function adds 20ms to the duration of the sensors ON pulse. 826001063 Rev.G Copyright Datalogic 2007-2009

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net