You are on page 1of 2

Automatic intermittent gear pump

AMZ- III [CE]


Lightweight and compact pump unit without controller.
Conforms to European Safety Standard. Oil level and
pressure switches are standard equipment.

Model Reference

AMZ [1.8] [3]


Reservoir Mounting Poition
Voltage
1 AC100V1
Blank Resin Specifications
F Foot Mount
2 AC200V1
B Wall Mount
23 AC230V1 Pump Discharge 90m/min (50Hz), 110m/min (60Hz)
*Metal reservoir only volume
Reservoir capacity Discharge 1.5MPa/217.5psi
pressure (safety valve set pressure)
Blank 1.8Resin reservoirs
3 3Resin reservoirs Motor Voltage / AC100V1/1.5A, AC200V1/0.8A (50Hz)
current AC100V1/1.3A, AC200V1/0.7A (60Hz)
30 3Metal reservoirs
Output 19W (50Hz), 18W (60Hz) Shading motor
40 4Metal reservoirs
80 8Metal reservoirs Emergency Oil level Contact type (NO) ON at low level
detection switch Contact capacity 0.5A, AC DC200V/30W smaller
*Pump is installed on the right
side, if a metal reservoir is Pressure Contact type (NO)
Model selected. switch Operating pressure: 1.3M ON
Reset pressure: 0.9MPa OFF
Model Part Number Contact capacity AC DC250V/2A
Operation Max. discharge time: 1 min.
AMZ-III -1 285017 Min.interval time: 3 min.
AMZ-III -1-3 285024 Working vis-
2
50-1300mm /S (50Hz)
AMZ-III -2 285016 cosity range
AMZ-III -2-3 285023 Reservoir 1.8, 3 (plastic) 3, 4, 8 (sheet metal)
capacity
AMZ-III -23 285433
Weight 1.8: 2.7kg 3: 3.6kg
Low viscosity oil pump (On the page of AMZ-III) External fuse 100V/2.0A, 200V/1.0A
Part No. Voltage Tank Working vis
No Model capacity cosity range * Should the pump malfunction, contact LUBE for consultation.

1 AMZ-3-100SL-18LP 285224 100V 1.8L 22~800mm2/S


2 AMZ-3-100SL-18LP 285426 200V 1.8L 22~800mm2/S

Directions for use


This pump unit requires a separate control circuit to operate.
Periodically check the oil in the reservoir for impurities.

Do not remove the oil fill strainer in order to keep the pump
Replace it, if necessary, with fresh oil immediately.
clear of foregn matter. Be sure to clean the reservoir before replacing oil.
Replace the suction filter at least once a year.
Make sure that proper voltage is applied.

Oil viscosity varies with oil temperature. Be sure to use oil within
Do not over tighten the discharge joint.

the working viscosity range. Refer to the viscosity table. (P.237) Refer to the torque table. (P. 251)

Do not use any special additive-contained oil, water soluble oil,
Low-oil viscosity versions are available. Contact us for information.
or solvent.

Related parts

For MO2(C) Valve For MO Valve For MOS Valve

MO2(C) Metering JVPA Junction MO Metering valve: PV Junction MOS Metering valve PVS Junction MB Metering valve MIX-S Metering valve
valve: P.115 : P.116 P.117 : P.118 : P.119 : P.121 : P.123 : P.127

F-3D Filter Pressure gauge Tubing Compression parts Adapters Reservoirs Flexible pipe nozzle with
: P.181 : P.186 : P.203 : P.201 : P.207 : P.171 metering valve: P.195

103
Dimensional drawing

Large Machines
Injector (PDI) System for
Positive Displacement
270
35

166
17

Discharge port

63
Discharge port M101
M101

135
54
Oil fill cap
120

Part Number
529409

Oil fill cap


Wiring port
Wiring port Part Number
529409
234
147

Part Number
521037 2M6
2M6 Installation hole
Installation hole
Strainer
Part Number
521037

(262)
(256)

177
171

Suction filter set Suction filter set


Part Number 489011 Part Number 489011

Parts for connecting to the discharge port


[1.8] [3]

CB-6 CS-6 TI-6

Improper handling can result in a death or serious injury Electrical shock may be received under certain conditions Be sure to ground.

Hydraulic circuit drawing Wiring diagram

PRESS. SW
P
EMG. OUT
C
OIL LEVEL. SW
RV
O
POWER Y
M
X
E Thermal protector

104

You might also like