You are on page 1of 40

THE RED BOOK

FIRE & ACOUSTIC DESIGN GUIDE


Addendum October 2015

GYPROCK OPTIMISED CORE PLASTERBOARDS

OVERVIEW GYPROCK PLUS 10mm


The CSR Gyprock Red Book contains a wide range of fire Gyprock Plus 10mm is part of the range of Residential
and/or acoustic rated wall systems. Select premium quality plasterboards. Manufactured using
This addendum provides updated acoustic performance Optimised Core technology, this 10mm thick plasterboard
information for systems that feature Gyprock products includes a stronger, thicker face paper which delivers
manufactured with Optimised Core technology Gyprock substantial performance benefits.
Plus and Gyprock Supaceil 10mm plasterboards. Gyprock Plus is primarily designed for internal wall linings,
predominantly in residential applications where no specific
OPTIMISED CORE TECHNOLOGY fire, acoustic or moisture resistant requirements are specified.
Gyprock Plus with Optimised Core technology weighs
Gyprock Optimised Core plasterboards have an advanced 5.7kg/m2.
performance-to-weight ratio, meaning greater breaking
strength in a substantially lighter board that continues GYPROCK SUPACEIL
to exceed the performance requirements of Australian
Standard AS2588.
Gyprock Supaceil is specifically designed for use as
The benefits of Optimised Core technology are stronger and an internal ceiling lining, predominantly in residential
lighter boards with better breaking strength for improved applications where no specific fire, acoustic or moisture
handling and installed performance, as well as crisper score resistant requirements are specified. This plasterboard
and snap. is manufactured with Optimised Core technology and
contains fibreglass reinforcement for greater strength and
AS2588 Performance Criteria
sag resistance for fixing at 600mm centres.
Sag (humidified deflection)
Gyprock Supaceil with Optimised Core technology weighs
Bending strength 6.1kg/m2 (6.5 kg/m2 in Western Australia).
Edge hardness
Gyprock Plus and Supaceil are not suitable where it would be in
Nail pull resistance contact with water, or for environments with a constant relative
Bond strength in tension humidity above 90%.

www.gyprock.com.au
Steel Frame Internal Wall Systems Single Stud
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 005a shown)

Lining material as per system table. ACOUSTIC


Steel Studs at 600mm maximum centres. OPINION
Lining material as per system table.
PKA-052
NOTES: Acoustic performance valid for studs
(51/64mm x 0.50 BMT) (76/92 x 0.55 BMT) (150mm x .075 BMT).

B
STUD DEPTH mm 51 64 76 92 150
FRL SYSTEM
WALL LININGS CAVITY INFILL
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 005 Plus (a) Nil 28/20 29/21 30/22 30/23 34/27
(b) 50 GW Acoustigard 11kg 36/28 37/29 38/30 38/31 41/34
BOTH SIDES
(c) 75 GW Acoustigard 11kg 39/31 39/31 39/32 42/35
// 1 x 10mm Gyprock Plus
(d) MSB3 Polyester 34/26 35/27 36/28 36/29 39/32
plasterboard.
(e) 60NG SoundScreen 1.7 39/31 39/31 40/32 40/33 43/36
WALL THICKNESS mm 71 84 96 112 170

Steel Frame Internal Wall Systems Double Stud


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 206b shown)

Lining material as per system table.


2 rows of Steel Studs at 600mm maximum centres with 20mm ACOUSTIC
minimum gap. OPINION
Lining material as per system table.
PKA-052
NOTES:
Acoustic performance valid for studs
(64mm x 0.50 BMT) (76/92 x 0.55 BMT) (150mm x .075 BMT).
*ACR = Axial Capacity Reduction. Refer to The Red Book.

STUD DEPTH mm 64 76 92 150


FRL SYSTEM MINIMUM CAVITY WIDTH mm 148 172 204 320
WALL LININGS
Report/Opinion N
CAVITY INFILL Rw / Rw+Ctr
(Refer to Bradford)
CSR 206 Plus (a) Nil 49/43 49/43 50/44 52/46
/90/90 BOTH SIDES (ANY ORDER) (b) 50 GW Acoustigard 11kg 57/48 57/48 58/49 60/51
60/60/60 1 x 10mm Gyprock Plus (c) 75 GW Acoustigard 11kg 60/51 59/50 60/51 62/53
90/90/90* plasterboard.
*ACR15% (d) MSB3 Polyester 53/46 53/46 54/47 56/49
1 x 16mm Gyprock Fyrchek
FAR2357 plasterboard. (e) 60NG SoundScreen 1.7 60/49 60/49 61/50 63/52
WALL THICKNESS mm 200 224 256 372

GYPROCK OPTIMISED CORE PLASTERBOARDS 2


Steel Frame Internal Wall Systems Party Wall 25mm Fire Barrier
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 100 shown) ACOUSTIC
OPINION
Lining material as per system table.
PKA-052
Steel studs at 600mm maximum centres.
Cavity insulation as per system table.
Discontinuous
20-40mm separation between frame and Gyprock Shaft Construction
Liner Panel.
25mm Gyprock Shaft Liner Panel between steel H-Studs
at 600mm maximum centres.
20-40mm separation between frame and Gyprock Shaft B
Liner Panel.
Cavity insulation as per system table.
Steel studs at 600mm maximum centres.
Lining material as per system table.
NOTES: Acoustic performance valid for studs (51/64mm x 0.50 BMT)
(76/92 x 0.55 BMT) (150mm x .075 BMT).

STUD DEPTH mm 64 76
FRL SYSTEM
WALL LININGS
Report/Opinion N CAVITY INFILL (Both Sides) Rw / Rw+Ctr
(Refer to Bradford)
CSR 100 Plus (a 50 GW Acoustigard 11kg 60/47 61/49

60/60/60 BOTH SIDES (b) 75 GW Acoustigard 14kg 63/50 64/52


2 x 10mm Gyprock Plus
EWFA 45743 plasterboard. (c) 60NG SoundScreen 1.7 63/50 64/52

MINIMUM WALL THICKNESS mm 233 257

GYPROCK OPTIMISED CORE PLASTERBOARDS 3


Steel Frame Internal Wall Systems SecurityWall
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 292a shown) ACOUSTIC
OPINION

PKA-054

Discontinuous
Lining material as per system table. Construction
Gyprock SecurityWall Panel 27.
Cavity determined by track width.
Gyprock SecurityWall Panel 27.

B Lining material as per system table.

FRL SYSTEM TRACK WIDTH mm 51 64


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr
CSR 292 Plus (a) Nil 50/42 52/44
BOTH SIDES
(b) 50 GW Acoustigard 11kg 57/49 59/51
/90/90 1 x 16mm Gyprock
Fyrchek plasterboard. (c) 75 GW Acoustigard 11kg 58/50 60/52
FAR2039 1 x 10mm Gyprock Plus (d) MSB4 Polyester 57/49 58/50
plasterboard.
WALL THICKNESS mm 157 170

SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 293a shown) ACOUSTIC


OPINION

PKA-054
Discontinuous
Lining material as per system table. Construction

Gyprock SecurityWall Panel 27.


Cavity width as per system table.
Steel Studs at 600mm maximum centres with minimum
20mm gap to Security Wall Panel.
Lining material as per system table.

FRL SYSTEM CAVITY WIDTH mm 84 96


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr
CSR 293 Plus (a) Nil 49/41 51/43
BOTH SIDES (b) 50 GW Acoustigard 11kg 56/48 58/50
/90/90 1 x 16mm Gyprock
Fyrchek plasterboard. (c) 75 GW Acoustigard 11kg 59/51
FAR2039 1 x 10mm Gyprock Plus (d) MSB4 Polyester 56/48 57/49
plasterboard.
WALL THICKNESS mm 163 175

GYPROCK OPTIMISED CORE PLASTERBOARDS 4


Steel Frame Internal Wall Systems SecurityWall
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 295a shown) ACOUSTIC
OPINION

PKA-054
Lining material as per system table.
Discontinuous
Gyprock SecurityWall Panel 50. Construction
Cavity determined by track width.
Gyprock SecurityWall Panel 50.
Lining material as per system table.

NOTES: SecurityWall Panel ribs offset to enable insulation to fit.


B
TRACK WIDTH mm 28 51 64
FRL SYSTEM
WALL LININGS CAVITY INFILL
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 295 Plus (a) Nil 51/44 53/46 54/47
BOTH SIDES
(b) 50 GW Acoustigard 11kg 58/51 60/53 61/54
/90/90 1 x 16mm Gyprock
Fyrchek plasterboard. (c) 75 GW Acoustigard 11kg 61/54 62/55
FCO 2039 1 x 10mm Gyprock Plus
(d) MSB4 Polyester 56/49 58/51 59/52
plasterboard.
WALL THICKNESS mm 180 203 216

SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 296a shown) ACOUSTIC


OPINION

PKA-054

Lining material as per system table. Discontinuous


Gyprock SecurityWall Panel 50. Construction

Cavity width as per system table.


Steel Studs at 600mm maximum centres with minimum
20mm gap to Security Wall Panel.
Lining material as per system table.

FRL SYSTEM CAVITY WIDTH mm 84 96 112


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr
CSR 296 Plus (a) Nil 51/43 52/45 53/46
BOTH SIDES (b) 50 GW Acoustigard 11kg 58/50 59/52 60/53
/90/90 1 x 16mm Gyprock
Fyrchek plasterboard. (c) 75 GW Acoustigard 11kg 59/51 60/53 61/54
FCO 2039 1 x 10mm Gyprock Plus (d) MSB4 Polyester 58/50 59/52 60/53
plasterboard.
WALL THICKNESS mm 186 198 214

GYPROCK OPTIMISED CORE PLASTERBOARDS 5


Steel Frame External Wall Systems RendaLine
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 165a shown) ACOUSTIC
OPINION

PKA-055
Cemintel RendaLine sheet on timber or steel battens.
Wall Wrap/Sarking.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

NOTE:

B Thermal performance based on 35mm battens, wall wrap of Bradford Enviroseal


Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 76 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr Rt(WIN) Rt(SUM)
CSR 165 Plus
(a) Nil 37/30 0.62 0.56

INTERNAL WALL SIDE (b) 75 Gold Batts 2.0 45/36 2.54 2.31
// 1 x 10mm Gyprock Plus
plasterboard. (c) 60 NG SoundScreen 1.7 46/38 2.23 2.03

WALL THICKNESS mm 129

SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 167a shown) ACOUSTIC


OPINION

PKA-055
Cemintel RendaLine sheet on timber or steel battens.
Wall Wrap/Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

NOTE:
Thermal performance based on 35mm battens, wall wrap of Bradford Enviroseal
Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 76 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 167 Plus (a) Nil 39 0.68 0.62
EXTERNAL SIDE

60/60/60 1 x 13mm Gyprock


Fyrchek MR plasterboard. (b) 75 Gold Batts 2.0 45 2.60 2.37
(from outside only)
INTERNAL SIDE
FAR2357 (c) 60 NG SoundScreen 1.7 46 2.28 2.08
1 x 10mm Gyprock Plus
plasterboard.
WALL THICKNESS mm 142

GYPROCK OPTIMISED CORE PLASTERBOARDS 6


Steel Frame External Wall Systems RendaLine
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 170a shown) ACOUSTIC
OPINION
Cemintel RendaLine sheet on timber or steel battens.
PKA-055
25mm Bradford Fibertex Rockwool.
Wire mesh.
Wall Wrap/Sarking
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

NOTE:
Thermal performance based on 35mm battens, wall wrap of Bradford Enviroseal
Proctorwrap RW.
B
FRL SYSTEM STUD DEPTH mm 76 THERMAL
WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr Rt(WIN) Rt(SUM)
CSR 170 Plus (a) Nil 39/31 1.05 0.99
EXTERNAL SIDE

60/60/60 As per system


specification (b) 75 Gold Batts 1.5 44/35 2.43 2.26
(from outside only)
INTERNAL SIDE
FAR2357 (c) 75 SoundScreen 2.0 45/36 2.96 2.73
1 x 10mm Gyprock Plus
plasterboard.
WALL THICKNESS mm 129

GYPROCK OPTIMISED CORE PLASTERBOARDS 7


Steel Frame External Wall Systems Cladding On Battens
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 121a shown) ACOUSTIC
OPINION

External cladding material on timber or steel battens. PKA-055


Wall Wrap/Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

NOTES:

B Acoustic performance valid for studs (51/64mm x 0.50 BMT) (76/92 x 0.55 BMT)
(150mm x .075 BMT).
*ACR = Axial Capacity Reduction. Refer to The Red Book.
Thermal performance based on 35mm battens, wall wrap of Bradford Enviroseal
Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 76 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 118 Plus (a) Nil 32 - 36 0.65 0.60
EXTERNAL SIDE OF STUD
1 x 13mm Gyprock
30/30/30 (b) 75 Gold Batts 1.5 38 - 42 2.04 1.87
Fyrchek MR plasterboard.
(from outside only)
FAR2357 INTERNAL SIDE
(c) 70 NG SoundScreen 2.0 39 - 43 2.57 2.35
1 x 10mm Gyprock Plus
plasterboard.
TYPICAL WALL THICKNESS mm 129

CSR 121 Plus (a) Nil 32 - 36 0.66 0.61


EXTERNAL SIDE OF STUD

60/60/60* 1 x 16mm Gyprock


(b) 75 Gold Batts 1.5 38 - 42 2.05 1.88
(from outside only) Fyrchek MR plasterboard.
*ACR 5% INTERNAL SIDE
FAR2357 (c) 70 NG SoundScreen 2.0 39 - 43 2.58 2.36
1 x 10mm Gyprock Plus
plasterboard.
TYPICAL WALL THICKNESS mm 132

CSR 119 Plus (a) Nil 36 - 40 0.71 0.65


EXTERNAL SIDE OF STUD
2 x 13mm Gyprock
90/90/90 (b) 75 Gold Batts 1.5 42 - 46 2.10 1.93
Fyrchek MR plasterboard.
(from outside only)
FAR2357 INTERNAL SIDE
(c) 70 NG SoundScreen 2.0 43 - 47 2.62 2.40
1 x 10mm Gyprock Plus
plasterboard.
TYPICAL WALL THICKNESS mm 142

CSR 123 Plus (a) Nil 36 - 40 0.73 0.68


EXTERNAL SIDE OF STUD

120/120/120 2 x 16mm Gyprock


(b) 75 Gold Batts 1.5 42 - 46 2.12 1.95
(from outside only) Fyrchek MR plasterboard.
INTERNAL SIDE
FAR2357 (c) 70 NG SoundScreen 2.0 43 - 47 2.65 2.43
1 x 10mm Gyprock Plus
plasterboard.
TYPICAL WALL THICKNESS mm 148

GYPROCK OPTIMISED CORE PLASTERBOARDS 8


Steel Frame External Wall Systems Texture Base Sheet For Houses
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 127a shown) ACOUSTIC
OPINION

1 x 7.5mm Cemintel Texture Base Sheet to exterior face. PKA-052

Wall Wrap/Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side of steel studs as per system
table.

NOTES:
Acoustic performance valid for studs (51/64mm x 0.50 BMT) (76/92 x 0.55 BMT)
B
(150mm x .075 BMT).
*ACR = Axial Capacity Reduction. Refer to The Red Book.
Thermal performance valid for wall wrap of Bradford Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 76 92 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw + Ctr Rt(WIN) Rt(SUM)
CSR 127 Plus (a) Nil 39/31 40/33 0.47 0.45
EXTERNAL SIDE OF STUD

60/60/60 1 x 13mm Gyprock


(b) 75 Gold Batts 1.5 47/39 48/41 2.40 2.20
(from outside only) Fyrchek MR plasterboard.
INTERNAL SIDE
FAR2357 (c) 70 NG SoundScreen 2.0 48/40 49/42 2.40 2.20
1 x 10mm Gyprock Plus
plasterboard.
WALL THICKNESS mm 107 123

CSR 126 Plus (a) Nil 40/32 41/34 0.49 0.46


EXTERNAL SIDE OF STUD

60/60/60 1 x 16mm Gyprock


(b) 75 Gold Batts 1.5 48/40 49/42 2.41 2.21
(from outside only) Fyrchek MR plasterboard.
INTERNAL SIDE
FAR2357 (c) 70 NG SoundScreen 2.0 49/41 50/43 2.41 2.21
1 x 10mm Gyprock Plus
plasterboard.
WALL THICKNESS mm 110 126

Steel Frame External Wall Systems Masonry


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 184a shown) ACOUSTIC
OPINION

PKA-055
Fire rated masonry veneer wall.
Steel studs at 600mm maximum centres with 40mm
minimum gap to masonry.
Lining material as per system table.

NOTES:
Masonry to be minimum 90mm thick and 170kg/m2
Thermal performance valid for 110mm extruded brick to AS4859.

FRL SYSTEM STUD DEPTH mm 92 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr Rt(WIN) Rt(SUM)
CSR 184 Plus (a) Nil 51/42 0.56 0.54
EXTERNAL WALL SIDE
FRL
Masonry veneer wall with
60/60/60 (b) 75 Gold Batts 1.5 58/49 2.16 1.99
from outside only FRL 60/60/60.
refer to INTERNAL WALL SIDE
Masonry
(c) 88 NG SoundScreen 2.5 59/50 3.22 2.94
1 x 10mm Gyprock Plus
Manufacturer
plasterboard.
TYPICAL WALL THICKNESS mm 252

GYPROCK OPTIMISED CORE PLASTERBOARDS 9


Timber Frame Internal Wall Systems Single Stud
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 305a shown) ACOUSTIC
OPINION

Lining material as per system table. PKA-051

Timber studs at 600mm maximum centres.


Cavity insulation as per system table.
Lining material as per system table.

NOTES:
Acoustic performance valid for 35mm wide studs at 600mm centres.

STUD DEPTH mm 70 90 120 140


FRL SYSTEM
WALL LININGS CAVITY INFILL
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 305 Plus (a) Nil 27/19 28/21 31/24 31/24

(b) 75 Gold Batts 1.5 32/24 33/26 36/29 36/29


C //
BOTH SIDES
1 x 10mm Gyprock Plus (c) 70NG SoundScreen 2.0 33/25 34/27 37/30 36/29
plasterboard.
(d) MSB3 Polyester 30/22 31/24 34/27 33/26

WALL THICKNESS mm 90 110 140 160


CSR 315 Plus (a) Nil 34/27 36/29 38/31 39/33

(b) 75 Gold Batts 1.5 39/32 41/34 43/36 44/38


BOTH SIDES
// 2 x 10mm Gyprock Plus (c) 70NG SoundScreen 2.0 40/33 42/35 44/37 44/38
plasterboard.
(d) MSB3 Polyester 37/30 39/32 41/34 41/35

WALL THICKNESS mm 110 130 160 180

CSR 352 Plus SIDE ONE (ANY ORDER) (a) Nil 36/29 38/31 40/33 41/35
1 x 10mm Gyprock Plus
/60/60 plasterboard. (b) 75 Gold Batts 1.5 41/34 43/36 45/38 46/40
and 1 x 13mm Gyprock
30/30/30 (c) 70NG SoundScreen 2.0 42/35 44/37 46/39 46/40
Fyrchek plasterboard.
FAR 2303 SIDE TWO (d) MSB3 Polyester 39/32 41/34 43/36 43/37
1 x 13mm Gyprock
Fyrchek plasterboard. WALL THICKNESS mm 106 126 156 176

Timber Frame Internal Wall Systems Double Stud


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 678b shown) ACOUSTIC
OPINION
Lining material as per system table.
PKA-051
2 rows Timber studs at 600mm maximum centres
in each row. Discontinuous
Construction
Cavity insulation as per system table.
20mm minimum gap and no connection between wall frames.
Lining material as per system table.

NOTES: Unless otherwise specified, cavity infill is required in one stud row only.

STUD DEPTH mm 70 90 120 140


FRL SYSTEM
WALL LININGS CAVITY INFILL
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 678 Plus (a) Nil 48/42 49/43 51/45 51/45
/60/60 BOTH SIDES
(b) 75 Gold Batts 1.5 59/51 60/52 62/54 62/54
and 1 x 10mm Gyprock Plus
60/60/60 plasterboard. (c) 70 SoundScreen 2.0 62/52 63/53 65/55 65/55
1 x 16mm Gyprock
FAR 2303 (d) MSB3 Polyester 54/48 55/49 57/51 57/51
Fyrchek plasterboard.
WALL THICKNESS mm 212 252 312 352

GYPROCK OPTIMISED CORE PLASTERBOARDS 10


Timber Frame Internal Wall Systems Party Wall with 25mm Fire Barrier
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 361a shown) ACOUSTIC
OPINION

PKA-018
Lining material as per system table.
Timber studs at 600mm maximum centres. Discontinuous
Construction
Cavity insulation as per system table.
20-40mm separation between frame and Gyprock Shaft
Liner Panel.
25mm Gyprock Shaft Liner Panel between steel H-Studs
at 600mm maximum centres.
20-40mm separation between frame and Gyprock Shaft
Liner Panel.
Cavity insulation as per system table.
Timber studs at 600mm maximum centres.
Lining material as per system table.

NOTES: Refer to GYP513 Gyprock Party Wall System for design considerations. C
STUD DEPTH mm 70 90
FRL SYSTEM
WALL LININGS CAVITY INFILL Both Sides
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 361 Plus
(a) 75 Gold Batts 2.0 62/49 63/51

60/60/60 BOTH SIDES (b) 90 Gold Batts 2.7 64/51 65/53


2 x 10mm Gyprock Plus
EWFA 45743 plasterboard. (c) 88NG SoundScreen 2.5 65/52 66/54

WALL THICKNESS mm 245 285


CSR 364 Plus
(a) 75 Gold Batts 2.0 64/52 64/52
BOTH SIDES (ANY ORDER)
60/60/60 1 x 10mm Gyprock (b) 90 Gold Batts 2.7 66/54 66/54
Superchek plasterboard.
EWFA 45743 1 x 10mm Gyprock Plus (c) 88NG SoundScreen 2.5 67/55 67/55
plasterboard.
WALL THICKNESS mm 245 285

GYPROCK OPTIMISED CORE PLASTERBOARDS 11


Timber Frame Internal Wall Systems Party Wall with 41mm Fire Barrier
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 369a shown) ACOUSTIC
OPINION

Lining material as per system table. PKA-018

Timber studs at 600mm maximum centres. Discontinuous


Cavity insulation as per system table. Construction

20-40mm separation between frame and Gyprock Shaft


Liner Panel.
25mm Gyprock Shaft Liner Panel between steel H-studs
at 600mm maximum centres.
16mm Gyprock Fyrchek screw laminated to Shaft Liner
Panel.
20-40mm separation between frame and Gyprock
Fyrchek plasterboard.
Cavity insulation as per system table.
Timber studs at 600mm maximum centres.

C Lining material as per system table.

NOTES: Refer to GYP513 Gyprock Party Wall System for design considerations.

STUD DEPTH mm 70 90
FRL SYSTEM
WALL LININGS CAVITY INFILL Both Sides
Report/Opinion N Rw / Rw+Ctr
(Refer to Bradford)
CSR 369 Plus
(a) 75 Gold Batts 2.0 64/52 65/53

90/90/90 BOTH SIDES (b) 90 Gold Batts 2.7 66/54 67/55


2 x 10mm Gyprock Plus
EWFA 45743 plasterboard (c) 60NG SoundScreen 1.7 66/54 67/55

WALL THICKNESS mm 261 301

Timber Frame Internal Wall Systems Staggered Stud


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 661b shown) ACOUSTIC
OPINION

PKA-051
Lining material as per system table.
Staggered timber studs at 600mm maximum centres each NOT
side. Deemed
Discontinuous
Minimum 20mm clearance between stud and opposing Construction
lining.
No noggings or any connection between studs.
Cavity insulation as per system table. (Insulation may need
to be cut and placed between studs).
Lining material as per system table.

FRL SYSTEM PLATE WIDTH mm 90 120 140


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford)) Rw / Rw+Ctr
CSR 661 Plus (a) Nil 38/31 40/33 42/35
SIDE ONE
1 x 10mm Gyprock Plus (b) 75 Gold Batts 1.5 47/39 49/41 51/43
plasterboard.
// (c) 70NG SoundScreen 2.0 49/39 51/41 52/42
SIDE TWO
1 x 6mm CeminSeal (d) MSB3 Polyester 43/36 45/38 46/39
Wallboard.
WALL THICKNESS mm 106 136 156

GYPROCK OPTIMISED CORE PLASTERBOARDS 12


Timber Frame External Wall Systems Cladding on Battens
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 900a shown) ACOUSTIC
OPINION

External cladding material on battens. PKA-055


Wall Wrap/Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
Thermal performance based on 35mm battens, wall wrap of Bradford Enviroseal
Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 900 Plus

60/60/60*
EXTERNAL WALL SIDE
1 x 16mm Gyprock Fyrchek
(a) Nil

(b) 75 Gold Batts 1.5


35

38
0.67

2.07
0.61

1.84
C
from outside only MR plasterboard.
* ACR Group 2
INTERNAL WALL SIDE
(c) 70 NG SoundScreen 2.0 39 2.60 2.37
FAR 2303 1 x 10mm Gyprock Plus
plasterboard. TYPICAL WALL THICKNESS mm 157

CSR 907 Plus


EXTERNAL WALL SIDE (a) Nil 37 0.71 0.66

90/90/90 2 x 13mm Gyprock Fyrchek


(b) 75 Gold Batts 1.5 40 2.12 1.94
from outside only MR plasterboard.
INTERNAL WALL SIDE
FAR 2303 (c) 70 NG SoundScreen 2.0 41 2.64 2.42
1 x 10mm Gyprock Plus
plasterboard. TYPICAL WALL THICKNESS mm 167

CSR 908 Plus (a) Nil 39 0.74 0.68


EXTERNAL WALL SIDE

120/120/120 2 x 16mm Gyprock Fyrchek


(b) 75 Gold Batts 1.5 42 2.14 1.97
from outside only MR plasterboard.
INTERNAL WALL SIDE
FAR 2303 (c) 70 NG SoundScreen 2.0 43 2.67 2.44
1 x 10mm Gyprock Plus
plasterboard.
TYPICAL WALL THICKNESS mm 173

GYPROCK OPTIMISED CORE PLASTERBOARDS 13


Timber Frame External Wall Systems Texture Base Sheet for Houses
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 902b shown) ACOUSTIC
OPINION

External cladding of 1 x 7.5mm CSR Cemintel Texture Base Sheet. PKA-051


Wall Wrap/Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
Thermal performance valid for wall wrap of Bradford Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr Rt(WIN) Rt(SUM)
CSR 902 Plus
C 60/60/60*
EXTERNAL WALL SIDE
1 x 13mm Gyprock Fyrchek
(a) Nil

(b) 90 Gold Batts 2.7


37/30

44/37
0.47

2.40
0.45

2.20
from outside only MR plasterboard.
* ACR Group 1 INTERNAL WALL SIDE
(c) 70 NG SoundScreen 2.0 43/36 2.40 2.20
FAR 2303 1 x 10mm Gyprock Plus
plasterboard. WALL THICKNESS mm 120

GYPROCK OPTIMISED CORE PLASTERBOARDS 14


Timber Frame External Wall Systems Masonry
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 923b shown) ACOUSTIC
OPINION

Fire rated masonry veneer wall. PKA-055


Timber studs at 600mm maximum centres with 40mm
minimum gap to masonry.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
To achieve stated acoustic performance masonry must be a minimum of 90mm thick
and 170kg/m2.
*ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr Rt(WIN) Rt(SUM)
CSR 923 Plus
EXTERNAL SIDE (a) Nil 51/43 0.56 0.54
60/60/60
Masonry veneer wall with
from outside only
FRL 60/60/60.
INTERNAL SIDE
(b) 75 Gold Batts 1.5

(c) 88 NG SoundScreen 2.5


58/49

59/50
2.16

3.22
1.99

2.94
C
Refer to masonry
manufacturer
1 x 10mm Gyprock Plus
plasterboard. WALL THICKNESS mm 250

Timber Frame External Wall Systems RendaLine


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 690a shown) ACOUSTIC
OPINION

1 x Cemintel RendaLine sheet on timber battens. PKA-051

Wall Wrap/Sarking.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.

NOTES:
Acoustic performance valid for 35mm wide studs at 600mm centres.
Thermal performance based on 35mm battens, wall wrap of Bradford
Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 690 Plus
(a) Nil 38 0.61 0.56

INTERNAL SIDE (b) 75 Gold Batts 1.5 44 2.02 1.84


// 1 x 10mm Gyprock Plus
plasterboard. (c) 88 NG SoundScreen 2.5 46 3.07 2.79

WALL THICKNESS mm 143

GYPROCK OPTIMISED CORE PLASTERBOARDS 15


Timber Frame External Wall Systems RendaLine
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 696b shown) ACOUSTIC
OPINION

1 x Cemintel RendaLine sheet on timber battens.


PKA-055
Wall Wrap/Sarking.
1 x 13mm Gyprock Fyrchek MR plasterboard.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
Thermal performance based on 35mm battens, wall wrap of Bradford
Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 696 Plus
EXTERNAL SIDE (a) Nil 42 0.66 0.61
C 60/60/60*
From outside only
As per system
specification. (b) 75 Gold Batts 1.5 48 2.07 1.89
* ACR Group 2
INTERNAL SIDE
FAR 2303
(c) 88 NG SoundScreen 2.5 50 3.13 2.85
1 x 10mm Gyprock Plus
plasterboard.
WALL THICKNESS mm 156

SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 697b shown) ACOUSTIC


OPINION
1 x Cemintel RendaLine sheet on timber battens.
PKA-051
25mm Bradford Fibertex 450 Rockwool (80kg/m3) between battens.
Wire mesh and Wall Wrap/Sarking.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
Thermal performance based on 35mm battens, wall wrap of Bradford
Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)
CSR 697 Plus
EXTERNAL SIDE (a) Nil 44 1.04 0.98

60/60/60 As per system


(b) 75 Gold Batts 1.5 46 2.43 2.26
From outside only specification.
INTERNAL SIDE
FAR 2303 (c) 88 NG SoundScreen 2.5 48 2.96 2.73
1 x 10mm Gyprock Plus
plasterboard. WALL THICKNESS mm 143

GYPROCK OPTIMISED CORE PLASTERBOARDS 16


Timber Frame External Wall Systems Commercial ExpressWall
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 905a shown) ACOUSTIC
OPINION

Cemintel Commercial ExpressWall system. PKA-055

Wall Wrap/Sarking.
1 x 16mm Gyprock Fyrchek MR plasterboard fixed to framing.
Timber stud framing as required.
1 layer x 10mm Gyprock Plus plasterboard fixed to framing.

NOTES: *ACR = Axial Capacity Reduction. (Refer to The Red Book Table C3).
Thermal performance based on 35mm battens, wall wrap of Bradford
Enviroseal Proctorwrap RW.

FRL SYSTEM STUD DEPTH mm 90 THERMAL


WALL LININGS
Report/Opinion N CAVITY INFILL (Refer to Bradford) Rw Rt(WIN) Rt(SUM)

CSR 905 Plus


(a) Nil 40 0.67 0.62 C
EXTERNAL SIDE OF FRAMING
1 layer x 16mm Gyprock (b) 75 Gold Batts 1.5 45 2.08 1.90
60/60/60*
from outside only Fyrchek MR plasterboard.
* ACR Group 2 INTERNAL SIDE OF FRAMING
1 layer x 10mm Gyprock
FAR 2303 (c) MSB4 Polyester 44 2.60 2.38
Plus plasterboard fixed to
framing.

WALL THICKNESS mm 160

Masonry Wall Systems - Stud One Side


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 739 shown) ACOUSTIC
OPINION

PKA-053

Discontinuous
Construction
Lining as per table, fixed to studs.
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

Masonry STUD DEPTH (mm) 64 92


SYSTEM
Wall WALL LININGS
N CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr
Requirements
Tested CSR 739 Plus (a) 75 GW Acoustigard 11kg 59/50 61/52
Brick, MASONRY SIDE
Block or 1 x 13mm Gyprock (b) 90 Gold Batts 2.0 60/51 62/53
Concrete Standard plasterboard
Wall with Rw STUD SIDE (c) MSB4 Polyester 58/49 60/51
> 46
1 x 10mm Gyprock Plus
Refer to Masonry
Wall Manufacturer plasterboard. ADDITIONAL WALL THICKNESS mm 104 132
for FRL Details

GYPROCK OPTIMISED CORE PLASTERBOARDS 17


Masonry Wall Systems - Stud Both Sides
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 775 shown) ACOUSTIC
OPINION

PKA-053

Lining as per table, fixed to studs. Discontinuous


Construction
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
12mm minimum cavity between masonry and framing.
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
Lining as per table, fixed to studs.

Masonry STUD DEPTH (mm) 64 92


SYSTEM
Wall WALL LININGS CAVITY INFILL (both sides)
N Rw / Rw+Ctr
Requirements (Refer to Bradford)

Tested (a) 75 GW Acoustigard 11kg 59/46 60/47


CSR 775 Plus
Brick,

D Block or
Concrete
Wall with Rw
BOTH SIDES
1 x 10mm Gyprock Plus
(b) 90 Gold Batts 2.0 60/47 61/48

(c) MSB4 Polyester 57/44 58/45


> 41 plasterboard.
Refer to Masonry
Wall Manufacturer ADDITIONAL WALL THICKNESS mm 172 228
for FRL Details

Tested (a) 75 GW Acoustigard 11kg 62/49 63/50


CSR 777 Plus
Brick,
Block or (b) 90 Gold Batts 2.0 64/50 64/51
Concrete BOTH SIDES
Wall with Rw 1 x 10mm Gyprock Plus (c) MSB4 Polyester 60/47 61/48
> 44 plasterboard.
Refer to Masonry
Wall Manufacturer ADDITIONAL WALL THICKNESS mm 172 228
for FRL Details

Tested (a) 75 GW Acoustigard 11kg 64/51 66/54


CSR 779 Plus
Brick,
Block or (b) 90 Gold Batts 2.0 65/52 67/55
Concrete BOTH SIDES
Wall with Rw 1 x 10mm Gyprock Plus (c) MSB4 Polyester 62/49 64/52
> 46 plasterboard.
Refer to Masonry
Wall Manufacturer ADDITIONAL WALL THICKNESS mm 172 228
for FRL Details

GYPROCK OPTIMISED CORE PLASTERBOARDS 18


Masonry Wall Systems - Stud and Furring Channel
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 549 shown) ACOUSTIC
OPINION

PKA-053

Lining as per table, fixed to studs. Discontinuous


Construction
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
28mm furring channel, fixed to masonry with 40mm
cavity.
Furring cavity infill, as per table.
Lining as per table, fixed to furring.

Masonry STUD DEPTH (mm) 64 92


SYSTEM
Wall WALL LININGS STUD CAVITY INFILL FURRING CAVITY INFILL
N Rw / Rw+Ctr
Requirements (Refer to Bradford) (Refer to Bradford)

Tested (a) 50 GW Acoustigard 11kg (a) 50 GW Acoustigard 11kg 60/46 62/49


Brick, CSR 549 Plus
Block or
Concrete
Wall with
BOTH SIDES
(b) 75 GW Acoustigard 11kg (b) 50 GW Acoustigard 11kg 62/48 64/51
D
1 x 10mm Gyprock (c) MSB4 Polyester (c) TBL 1025 58/44 60/47
Rw > 46 Plus plasterboard.
Refer to
Masonry Wall
ADDITIONAL WALL THICKNESS mm 136 164
Manufacturer
for FRL Details

GYPROCK OPTIMISED CORE PLASTERBOARDS 19


Floor/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 803a shown) ACOUSTIC
OPINION

Floor finished bare or with carpet and underlay, as per PKA056


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists at 600mm maximum centres.
Minimum 190mm cavity depth.
Cavity infill as per system table.
Ceiling lining as per system table, direct fixed to framing.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 803
(a) Nil 37/30 80-85 60-65

1 x 10mm Gyprock
// (b) 90 Gold Batts 2.0 40/32 80-85 60-65
Supaceil plasterboard.

(c) 75NG SoundScreen 2.0 40/32 80-85 60-65

E SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 886a shown) ACOUSTIC


OPINION

Floor finished bare or with carpet and underlay, as per PKA056


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists.
Minimum 205mm cavity depth.
RONDO Furring Channels.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 810
(a) Nil 39/32 60-65

1 x 10mm Gyprock
// (b) 90 Gold Batts 2.0 44/35 80-85 60-62
Supaceil plasterboard.

(c) 75NG SoundScreen 2.0 45/36 80-85 60-62

CSR 886 Plus


(a) Nil 39/32 80-85 60-65

1 x 10mm Gyprock
// (b) 90 Gold Batts 2.0 44/37 80-85 60-62
Plus plasterboard.

(c) 75NG SoundScreen 2.0 45/38 80-85 60-62

GYPROCK OPTIMISED CORE PLASTERBOARDS 20


Floor/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 257a shown) ACOUSTIC
OPINION

PKA056
150mm concrete slab.
RONDO furring channel.
Cavity infill as per system table in 45mm cavity.
Ceiling lining as per system table, fixed to furring channel.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 257 Plus
(a) Nil 54/42 70-75 40-45

Refer to 1 x 10mm Gyprock


(b) 50 GW Acoustigard 58/47 65-70 40-45
AS3600 Plus plasterboard.

(c) MSB3 Polyester 57/46 65-70 40-45

CSR 259
(a) Nil 55/43 70-75 40-45

Refer to 1 x 10mm Gyprock


(b) 50 GW Acoustigard 59/48 65-70 40-45
AS3600 Supaceil plasterboard.

(c) MSB3 Polyester 58/47 65-70 40-45

E
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 339a shown) ACOUSTIC
OPINION

150mm concrete slab.


PKA056
Gyprock Resilient Mounts direct fixed to concrete slab at
600 x 1200mm maximum centres.
RONDO furring channel.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 337 Plus
(a) Nil 56/44 65-70 35-40

Refer to 1 x 10mm Gyprock


(b) 50 GW Acoustigard 60/49 62-65 35-40
AS3600 Plus plasterboard.

(c) MSB3 Polyester 59/49 62-65 35-40

CSR 339
(a) Nil 57/45 65-70 35-40

Refer to 1 x 10mm Gyprock


(b) 50 GW Acoustigard 61/50 62-65 35-40
AS3600 Supaceil plasterboard.

(c) MSB3 Polyester 60/49 62-65 35-40

GYPROCK OPTIMISED CORE PLASTERBOARDS 21


Floor/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 457b shown) ACOUSTIC
OPINION

PKA056
125mm concrete slab.
RONDO Suspended Ceiling System.
Minimum 150mm cavity.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 457 Plus (a) Nil 58/49 65 70 40 45

(b) 50 GW Acoustigard 61/53 62 65 40 45


Refer to 1 x 10mm Gyprock
AS3600 Plus plasterboard.
(c) 75 GW Acoustigard 62/54 62 65 40 45

(d) MSB4 Polyester 61/53 62 65 40 45

CSR 459 (a) Nil 59/50 65 70 40 45

(b) 50 GW Acoustigard 62/54 62 65 40 45


Refer to 1 x 10mm Gyprock
AS3600 Supaceil plasterboard.
(c) 75 GW Acoustigard 63/55 62 65 40 45

(d) MSB4 Polyester 62/54 62 65 40 45

E Floor/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 557a shown) ACOUSTIC
OPINION

PKA056
125mm concrete slab.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Minimum 150mm cavity.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

SYSTEM CAVITY INFILL Carpet +


FRL Bare Floor
CEILING LININGS Rw / Rw+Ctr Underlay
Report/Opinion N (Refer to Bradford) Ln,w+CI
Ln,w+CI
CSR 557 Plus (a) Nil 59/50 60 65 35 40

(b) 50 GW Acoustigard 62/54 60 65 35 40


Refer to 1 x 10mm Gyprock
AS3600 Plus plasterboard.
(c) 75 GW Acoustigard 63/55 60 65 35 40

(d) MSB4 Polyester 62/54 60 65 40 45

CSR 559 (a) Nil 61/51 60 65 35 40

(b) 50 GW Acoustigard 63/55 60 65 35 40


Refer to 1 x 10mm Gyprock
AS3600 Supaceil plasterboard.
(c) 75 GW Acoustigard 64/56 60 65 35 40

(d) MSB4 Polyester 63/55 60 65 40 45

GYPROCK OPTIMISED CORE PLASTERBOARDS 22


Roof/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 948 shown) ACOUSTIC
OPINION

A pitched tiled roof with or without 350g/m2 sarking. PKA056


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses at 600mm maximum centres
(except where noted in system table).
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

Steel Roofing Tiled Roof Tiled Roofing


FRL SYSTEM CAVITY INFILL with Anticon without Sarking with Sarking
CEILING LININGS
Report/Opinion N (Refer to Bradford)
Rw / Rw+Ctr
CSR 948 Plus
(a) 165 Gold Batts 3.0 41/31 39/34 41/35
1 x 10mm Gyprock
Plus plasterboard.
// (b) 215 Gold Batts 4.1 42/33 40/35 42/37
NOTE: Framing at
450mm max. centres.
(c) 110NG SoundScreen 3.1 41/32 39/44 41/36

CSR 949
(a) 165 Gold Batts 3.0 41/31 39/34 41/35

1 x 10mm Gyprock
// (b) 215 Gold Batts 4.1 42/33 40/35 42/37
Supaceil plasterboard.

(c) 110NG SoundScreen 3.1 42/33 40/35 42/37

SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 843 shown) ACOUSTIC


OPINION
E
PKA056
A pitched tiled roof with or without 350g/m2 sarking.
OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring Channel.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

Steel Roofing Tiled Roof Tiled Roofing


FRL SYSTEM CAVITY INFILL with Anticon without Sarking with Sarking
CEILING LININGS
Report/Opinion N (Refer to Bradford)
Rw / Rw+Ctr
CSR 862 Plus
(a) 165 Gold Batts 3.0 42/33 41/36 43/37

1 x 10mm Gyprock
// (b) 215 Gold Batts 4.1 44/35 42/37 44/39
Plus plasterboard.

(c) 110NG SoundScreen 3.1 43/34 41/36 43/38

CSR 843 Plus


(a) 165 Gold Batts 3.0 46/36 44/39 46/40

2 x 10mm Gyprock
// (b) 215 Gold Batts 4.1 47/38 45/40 47/42
Plus plasterboard.

(c) 110NG SoundScreen 3.1 46/37 44/39 46/41

GYPROCK OPTIMISED CORE PLASTERBOARDS 23


Roof/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 854 shown) ACOUSTIC
OPINION

PKA056
A pitched tiled roof with or without 350g/m2 sarking.
OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring Channel clipped to Gyprock Resilient
Mounts.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

Steel Roofing Tiled Roof Tiled Roofing


FRL SYSTEM CAVITY INFILL with Anticon without Sarking with Sarking
CEILING LININGS
Report/Opinion N (Refer to Bradford)
Rw / Rw+Ctr
CSR 854
(b) 165 Gold Batts 3.0 45/35 43/38 45/39

1 x 10mm Gyprock
// (d) 215 Gold Batts 4.1 46/37 44/39 46/41
Supaceil plasterboard.

(e) 110NG SoundScreen 3.1 46/37 44/40 46/41

E Roof/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 896a shown) ACOUSTIC
OPINION

PKA056

Steel sheet roof


Bradford Anticon 55 over timber or steel purlins.
RONDO Suspended Ceiling System.
Cavity infill as per system table.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Ceiling lining as per system table, fixed to furring channel.

FRL SYSTEM CAVITY INFILL


CEILING LININGS Rw / Rw+Ctr
Report/Opinion N (Refer to Bradford)

CSR 896
(a) 140 Gold Batts 2.5 44/35

1 x 10mm Gyprock
//
Supaceil plasterboard.

(b) 110NG SoundScreen 3.1 45/36

GYPROCK OPTIMISED CORE PLASTERBOARDS 24


Roof/Ceiling Systems
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 065 shown) ACOUSTIC
OPINION

PKA056

Steel sheet roof


Bradford Anticon 55 over timber or steel purlins.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL SYSTEM CAVITY INFILL


CEILING LININGS Rw / Rw+Ctr
Report/Opinion N (Refer to Bradford)

CSR 065 Plus (a) 115 Gold Batts 2.0 44/35


(b) 140 Gold Batts 2.5 45/36

1 x 10mm Gyprock (c) 165 Gold Batts 3.0 45/36


//
Plus plasterboard. (d) 185 Gold Batts 3.5 46/37
(e) 215 Gold Batts 4.1 46/37
(f) 110NG SoundScreen 3.1 45/36
CSR 066 (a) 115 Gold Batts 2.0 45/36
(b) 140 Gold Batts 2.5 46/37

1 x 10mm Gyprock (c) 165 Gold Batts 3.0 46/37


//
Supaceil plasterboard. (d) 185 Gold Batts 3.5 47/38
(e) 215 Gold Batts 4.1
(f) 110NG SoundScreen 3.1
47/38
46/37
E
Ceiling Fire Rated from Above
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 983a shown) ACOUSTIC
OPINION

PKA052

Ceiling lining as per system table, fixed to framing.


Steel framing maximum 1.6 BMT at 600mm maximum
centres.
Minimum cavity depth 150mm.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL SYSTEM
CEILING LININGS CAVITY INFILL (Refer to Bradford) Rw / Rw+Ctr
Report/Opinion N
ABOVE (a) Nil 36/29
60/60/60
from top CSR 981 1 x 16mm Gyprock Fyrchek plasterboard. (b) 50 GW Acoustigard 11kg 43/36
only Plus BELOW
FAR 2358 (c) 90 Gold Batts 2.0 46/39
1 x 10mm Gyprock Plus plasterboard.
ABOVE (a) Nil 41/34
120/120/120
from top CSR 983 2 x 16mm Gyprock Fyrchek plasterboard.
only Plus BELOW (b) 75 GW Acoustigard 11kg 48/41
FAR 2358 1 x 10mm Gyprock Plus plasterboard.

GYPROCK OPTIMISED CORE PLASTERBOARDS 25


Services Systems with Timber Framing Rw + Ctr
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR SS04 shown) ACOUSTIC
OPINION

PKA058

Service Shaft or Ceiling

Timber studs or joists (min. 70 x 35mm) with direct fixed lining as


per system table.

Cavity with insulation as per system table.

Pipe with insulation as per system table.

Maximum N
System N Linings Cavity Insulation Pipe Lagging Downlights Rw + Ctr
per 5m2
CSR SS04 Plus
(a) Nil Nil 0 25

2 x 10mm Gyprock Plus


plasterboard.
(b) 75 GW Acoustigard 11kg Acoustilag 45 5 42

Services Systems with Steel Framing Rw + Ctr


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR SS13 shown) ACOUSTIC
OPINION

PKA058

F Service Shaft or Ceiling

Steel studs, joists or furring channels with direct fixed lining as


per system table.

Cavity with insulation as per system table.

Pipe with insulation as per system table.

Maximum N
System N Linings Cavity Insulation Pipe Lagging Downlights Rw + Ctr
per 5m2
CSR SS13 Plus
(a) Nil Nil 0 23
2 x 10mm Gyprock Plus
plasterboard.
(b) 75 GW Acoustigard 11kg Acoustilag 45 5 41

GYPROCK OPTIMISED CORE PLASTERBOARDS 26


Services Systems with Steel Framing Rw
SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR SS34 shown) ACOUSTIC
OPINION
Service Shaft or Ceiling
PKA058

Steel studs, joists or furring channels with direct


fixed lining as per system table.

Cavity with insulation as per system table.

Pipe with insulation as per system table.

Maximum N
System N Linings Cavity Insulation Pipe Lagging Downlights Rw
per 5m2
CSR SS34 Plus
(a) 75 GW Acoustigard 11kg Nil 5 30

2 x 10mm Gyprock Plus


plasterboard.
(b) 75 GW Acoustigard 11kg Acoustilag 45 5 51

Services Systems with Cavity Timber or Steel Framing Rw/Rw+Ctr


SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR SS40 shown) ACOUSTIC
OPINION

PKA052
Service Shaft or Ceiling

Inner layer lining (as per system table) direct fixed to timber
or steel framing, to encase services.

Cavity of 70mm minimum.

Cavity insulation as per system table. For ceiling, minimum


F
1200mm each side of pipe or duct.

Outer layer/ceiling lining (as per system table) direct fixed


to timber or steel framing. 12mm minimum gap between
framing and inner lining.

Maximum N
Insulation
System N Linings Downlights Rw/Rw+Ctr
(Refer to System Specification)
per 5m2
CSR SS40 Plus
INNER LAYER (a) 50 GW Acoustigard 11kg Nil 46/35

1 x 13mm Gyprock Soundchek plasterboard.


OUTER LAYER/CEILING
1 x 10mm Gyprock Plus plasterboard. (b) MSB4 Polyester Nil 43/34

CSR SS41 Plus


INNER LAYER (a) 50 GW Acoustigard 11kg Nil 50/39
2 x 13mm Gyprock Fyrchek plasterboard.
OUTER LAYER/CEILING
1 x 10mm Gyprock Plus plasterboard. (b) MSB4 Polyester Nil 47/38

GYPROCK OPTIMISED CORE PLASTERBOARDS 27


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031
Steel angle to Rondo DUO Two-way
support ceiling grid Steel Grid Ceiling
Floor or roof structure. 100mm System
System insulation min System insulation
200mm minimum cavity.
50mm Bradford Glasswool Acoustigard
11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating. GYPROCK
Panel
Ceiling
System

EXTENT OF INSULATION
1200mm each side
SYSTEM N CEILING LININGS Nil Entire Ceiling
of the wall
Rw
(a) 10mm Gyprock plasterboard panel. 38 44 45

(b) Ecophon 20mm Focus A, Ds or E 20mm. 21 24 25


CSR FP01 (c) Ecophon 20mm Focus Glasswool Panels + plasterboard
42 48 49
panels 10mm.
(d) Ecophon Master A 40mm. 30 31 31

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

PKAA031

100mm
Floor or roof structure. System insulation min System insulation

200mm minimum cavity. Ceiling Framing

50mm Bradford Glasswool Acoustigard


11kg/m3 to extent specified in table.
Ceiling lining as per system table.
G Wall with required sound rating. GYPROCK
plasterboard
Tape and set or
cornice finish
ceiling

EXTENT OF BUILDING BLANKET


1200mm each side
SYSTEM N CEILING LININGS Nil Entire Ceiling
of the wall
Rw / Rw+Ctr
(a) 1 x 10mm Gyprock Plus plasterboard. 41/32 47/38 48/39

(b) 1 x 13mm Gyprock Standard plasterboard. 43/34 49/40 50/41

(c) 1 x 13mm Gyprock Fyrchek Plasterboard. 46/38 52/44 53/45


CSR FP02
Plus (d) 1 x 13mm + 1 x 16mm
55/47 59/51 60/52
Gyprock Fyrchek Plasterboard.
(e) 2 x 13mm Gyprock Fyrchek Plasterboard. 54/46 58/50 59/51

(f) 2 x 16mm Gyprock Fyrchek Plasterboard. 55/47 59/51 60/52

GYPROCK OPTIMISED CORE PLASTERBOARDS 28


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION
Fix wall track to ceiling
System frame with Rondo 704
insulation Partition Clip PKAA031

Floor or roof structure.


200mm minimum cavity.
50mm Bradford Glasswool Acoustigard
11kg/m3 to extent specified in table. GYPROCK Panel Finish Bead as
Ceiling System required
Ceiling lining as per system table. continuous over
wall in Rondo Continuous bead of
Wall with required sound rating, to underside DUO Two-way CSR Gyprock
Steel Grid Sealant or a closed
of ceiling. cell foam tape
above wall track

EXTENT OF BUILDING BLANKET


1200mm each side
SYSTEM N CEILING LININGS Nil Entire Ceiling
of the wall
Rw
(a) 10mm Gyprock plasterboard panel. 35 40 42

CSR FP03 (b) Ecophon Focus A, Ds or E 20mm. 18-21 18-24 18-25

(c) Ecophon Master A 40mm. 25-30 25-31 25-31

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION
System insulation Ceiling framing
PKAA031

Floor or roof structure.


200mm minimum cavity.
50mm Bradford Glasswool Acoustigard Tape and
GYPROCK
11kg/m3 to extent specified in table. plasterboard set or
ceiling system cornice
Ceiling lining as per system table. continuous finish
over wall
Wall with required sound rating, to underside
of ceiling.
G
EXTENT OF BUILDING BLANKET
1200mm each side
SYSTEM N CEILING LININGS Nil Entire Ceiling
of the wall
Rw
(a) 1 x 10mm Gyprock Plus plasterboard. 36 41 41

(b) 1 x 13mm Gyprock Standard plasterboard. 39 45 45

(c) 1 x 16mm Gyprock Fyrchek Plasterboard. 43 48 50


CSR FP04
Plus (d) 1 x 13mm + 1 x 16mm
47 48 50
Gyprock Fyrchek Plasterboard.
(e) 2 x 13mm Gyprock Fyrchek Plasterboard. 47 48 50

(f) 2 x 16mm Gyprock Fyrchek Plasterboard. 48 48 50

GYPROCK OPTIMISED CORE PLASTERBOARDS 29


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031

600mm

Floor or roof structure.


200mm minimum cavity.
600mm wide barrier of Bradford Glasswool
Acoustigard 11kg/m3, compressed 30%.
GYPROCK Panel Finish Bead as
Ceiling lining as per system table. Ceiling System required
continuous over
Wall with required sound rating, to underside wall in Rondo Continuous bead of
of ceiling. DUO Two-way CSR Gyprock
Steel Grid Sealant or a closed
cell foam tape
Bradford above wall track
Glasswool
Acoustigard
11kg/m3
compressed 30%

SYSTEM N CEILING LININGS Rw


CSR FP10 (a) 10mm Gyprock plasterboard panel. 45

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

PKAA031

600mm
Ceiling
framing
Floor or roof structure.
200mm minimum cavity.
600mm wide barrier of Bradford Glasswool
Acoustigard 11kg/m3, compressed 30%.
GYPROCK Tape and
Ceiling lining as per system table. plasterboard set or

G Wall with required sound rating, to underside


of ceiling.
ceiling system
continuous
over wall
cornice
finish

Bradford
Glasswool
Acoustigard
11kg/m3
compressed 30%

SYSTEM N CEILING LININGS Rw

(a) 1 x 10mm Gyprock Plus plasterboard. 50

(b) 1 x 13mm Gyprock Standard plasterboard. 50

(c) 1 x 16mm Gyprock Fyrchek plasterboard. 50


CSR FP11 Plus
(d) 1 x 13mm + 1 x 16mm Gyprock Fyrchek plasterboard. 50

(e) 2 x 13mm Gyprock Fyrchek plasterboard. 50

(f) 2 x 16mm Gyprock Fyrchek plasterboard. 50

GYPROCK OPTIMISED CORE PLASTERBOARDS 30


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031
50mm Bradford Glasswool
Acoustigard seal continuous 10mm GYPROCK
over wall, held in place with plasterboard min.
track or angle continuous over wall
and fixed to soffit
Floor or roof structure.
200mm minimum cavity.
10mm Gyprock Plus plasterboard barrier with
50mm Bradford Glasswool Acoustigard seal.
Ceiling lining as per system table. GYPROCK Panel Finish Bead as
Ceiling System in required
Wall with required sound rating, to underside Rondo DUO
of ceiling. Two-way Steel Fix track to ceiling
Grid frame with Rondo
Screw fix ceiling N704
tile to wall track
Continuous bead of
CSR Gyprock
Wall with required Sealant above wall
sound rating track

SYSTEM N CEILING LININGS Rw

(a) 10mm Gyprock plasterboard panel. 46


CSR FP16
(b) Ecophon Focus A, Ds or E 20mm 35 40

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

PKAA031
50mm Bradford Glasswool
Acoustigard seal continuous 10mm GYPROCK
over wall, held in place with plasterboard min.
track or angle continuous over wall
Floor or roof structure. and fixed to soffit
200mm minimum cavity. Ceiling frame
10mm Gyprock Plus plasterboard barrier min.
with 50mm Bradford Glasswool Acoustigard
seal.
Ceiling lining as per system table. GYPROCK
plasterboard Tape and set or
Wall with required sound rating, to underside ceiling system cornice finish
of ceiling. continuous
over wall
Fix wall track to
G
Wall with required ceiling framing
sound rating

SYSTEM N CEILING LININGS Rw

(a) 1 x 10mm Gyprock Plus plasterboard. 50

(b) 1 x 13mm Gyprock Standard plasterboard. 50

(c) 1 x 16mm Gyprock Fyrchek plasterboard. 50


CSR FP17 Plus
(d) 1 x 13mm + 1 x 16mm Gyprock Fyrchek plasterboard. 50

(e) 2 x 13mm Gyprock Fyrchek plasterboard. 50

(f) 2 x 16mm Gyprock Fyrchek plasterboard. 50

GYPROCK OPTIMISED CORE PLASTERBOARDS 31


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031
Bradford Wavebar Quadzero
(4.0kg/m2) continuous over
wall and fixed to soffit 50mm Bradford
Acoustigard
Floor or roof structure. 300mm min. continuous over wall

200mm minimum cavity. 600mm min.


Bradford Wavebar Quadzero (4.0kg/m2)
continuous over wall and fixed to soffit with
50mm Bradford Glasswool Acoustigard seal.
Ceiling lining as per system table. GYPROCK Panel Finish Bead as
Ceiling System in required
Wall with required sound rating, to underside Rondo DUO
Two-way Steel Continuous bead of
of ceiling. Grid CSR Gyprock Sealant
Fix track to ceiling or closed cell foam
frame with Rondo tape above wall track
part 704
Wall with required
Screw fix ceiling sound rating
tile to wall track

SYSTEM N CEILING LININGS Rw

(a) 10mm Gyprock Plus plasterboard panel. 46


CSR FP20
(b) Ecophon Focus A, Ds or E 20mm. 35 40

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

PKAA031

Bradford Wavebar Quadzero


(4.0kg/m2) continuous over 50mm Bradford
wall and fixed to soffit Acoustigard
Floor or roof structure. 300mm min. continuous over wall

200mm minimum cavity. 600mm min.


Bradford Wavebar Quadzero (4.0kg/m2)
continuous over wall and fixed to soffit with
50mm Bradford Glasswool Acoustigard seal.
Ceiling lining as per system table. GYPROCK
plasterboard Tape and set or
Wall with required sound rating, to underside ceiling system cornice finish
continuous

G of ceiling. over wall

Wall with required


Fix wall track to
ceiling framing
sound rating

SYSTEM N CEILING LININGS Rw / Rw+Ctr

(a) 1 x 10mm Gyprock Plus plasterboard. 50/40

(b) 1 x 13mm Gyprock Standard plasterboard. 50/40

(c) 1 x 16mm Gyprock Fyrchek plasterboard. 50/41


CSR FP21 Plus
(d) 1 x 13mm + 1 x 16mm Gyprock Fyrchek plasterboard. 50/42

(e) 2 x 13mm Gyprock Fyrchek plasterboard. 50/42

(f) 2 x 16mm Gyprock Fyrchek plasterboard. 50/42

GYPROCK OPTIMISED CORE PLASTERBOARDS 32


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION
Floor or roof structure
PKAA031

Floor or roof structure.


50mm Bradford Glasswool Acoustigard
11kg/m3 to 1200mm min. each side of wall.
Ceiling lining as per system table. GYPROCK panel 50mm Bradford
ceiling system Acoustigard
Wall with required sound rating. 11kg/m3 1200mm
each side of wall
Wall system with
required rating

SYSTEM N CEILING LININGS Rw

(a) 10mm Gyprock Plasterboard panel. 46


CSR FP025
(b) Ecophon Focus A, Ds or E 20mm 40

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION
Floor or roof structure
PKAA031

50mm Bradford
Acoustigard
11kg/m3 1200mm
each side of wall

Floor or roof structure.


50mm Bradford Glasswool Acoustigard
11kg/m3 to 1200mm min. each side of wall.
GYPROCK
Ceiling lining as per system table. plasterboard ceiling Tape and set or
Wall with required sound rating. system cornice finish or
shadowline bead G
Wall system with
required rating

SYSTEM N CEILING LININGS Rw

(a) 1 x 10mm Gyprock Plus plasterboard. 49

(b) 1 x 13mm Gyprock Standard plasterboard. 52


CSR FP26 Plus
(c) 1 x 10mm Gyprock Superchek Plasterboard. 54

(d) 1 x 13mm Gyprock Soundchek Plasterboard. 55

GYPROCK OPTIMISED CORE PLASTERBOARDS 33


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031

Roof structure. Roof framing


with 500mm
500mm minimum average cavity height. R2.5 Glasswool min. average
Gold Batts cavity
Bradford 90mm Gold Batts R2.5.
Upper Ceiling 1 x 13mm + 1 x 16mm
Gyprock Fyrchek plasterboard.
Cavity 150mm minimum height with 50mm
13mm + 16mm
Bradford Glasswool Acoustigard 11kg/m3. 150mm min. cavity GYPROCK FYRCHEK
Plasterboard
Lower Ceiling Lining as per system table.
Wall with required sound rating, to underside
of upper ceiling.
Lower ceiling 50mm Bradford
Acoustigard 11kg/m3

Wall system with Tape and set or


required rating cornice finish

SYSTEM N LOWER CEILING LININGS Rw / Rw+Ctr

(a) 1 x 10mm Gyprock Plus plasterboard. 65/53

(b) 1 x 13mm Gyprock Standard plasterboard. 66/54


CSR FP31 Plus
(c) 1 x 10mm Gyprock Superchek Plasterboard. 66/54

(d) 1 x 13mm Gyprock Soundchek Plasterboard. 67/55

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

PKAA031
Sheet metal or
tiled roof

Roof framing with 500mm


min. average cavity
Roof structure. Bradford Gold
batts R2.5
500mm minimum average cavity height.
Bradford 90mm Gold Batts R2.5.
G Ceiling lining as per system table fixed with
28mm furring channel and clips to framing.
Wall with required sound rating. GYPROCK Furring channel
plasterboard ceiling and min. 40mm
cavity

Tape and set or


Wall system with cornice finish
required rating

SYSTEM N CEILING LININGS Rw / Rw+Ctr

(a) 1 x 10mm Gyprock Plus plasterboard. 47/39

(a) 1 x 13mm Gyprock Standard plasterboard. 51/43

CSR FP35 (a) 1 x 10mm Gyprock Superchek Plasterboard. 52/44

(a) 1 x 13mm Gyprock Fyrchek Plasterboard. 53/45

(a) 1 x 13mm + 1 x 16mm Gyprock Fyrchek Plasterboard. 59/51

GYPROCK OPTIMISED CORE PLASTERBOARDS 34


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION
Sheet metal or tiled roof
PKAA031

Roof structure. Bradford


Rockwool
Bradford Rockwool Fireseal insulation packed Fireseal
Roof framing with insulation
firmly between battens and roofing. min. 200mm cavity
Bradford Gold
200mm minimum average cavity height. batts R2.5
Bradford 90mm Gold Batts R2.5.
Ceiling lining as per system table fixed to
framing.
Wall with required sound rating. Masonry GYPROCK
plasterboard ceiling
wall 110mm min.. thickness, extending to (no acoustically Tape and set or
underside of roof battens. untreated lights,vents cornice finish
or similar penetrations)
Wall system with
Masonry wall min. required rating
110mm thick

SYSTEM N CEILING LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 65/55
CSR FP40
(b) 1 x 10mm Gyprock Supaceil Plasterboard. 65/55

GYPROCK OPTIMISED CORE PLASTERBOARDS 35


Flanking Paths via Ceiling
SYSTEM SPECIFICATION TYPICAL LAYOUT (Refer to detail below table) ACOUSTIC
OPINION

PKAA031

Roof structure.
500mm minimum average cavity height.
Bradford 75mm Gold Batts R1.5.
Ceiling lining as per system table fixed to framing.
CSR Party Wall system with required sound rating. Central
barrier extending to underside of roof battens.

SYSTEM N CEILING LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 66/54
CSR FP50
(b) 1 x 10mm Gyprock Supaceil Plasterboard. 66/54

Nominal 10mm gap to top of GYPROCK


Non-combustible roofing SHAFT LINER PANEL (track optional) Battens may be continuous over party
wall. Refer to BCA requirements

Roof battens
Fill void between Roof sarking.
battens with Bradford For roofs without sarking,
Rockwool Fireseal, protect Rockwool with
Roof framing 300mm min. width Wall Clips at damp course under tiles
each H-Stud
both sides of wall

16mm GYPROCK FYRCHECK


laminated to GYPROCK SHAFT
LINER PANEL laminating screws at
400mm x 400mm max. centres

Required acoustic insulation


minimum 75mm Bradford
R1.5 Gold batts 600mm max. Required acoustic insulation
minimum 75mm Bradford
Blocking to support R1.5 Gold batts
ceiling lining

G No acoustically
untreated lights,
vents or similar
Tape and set or
cornice finish 200mm min.
No acoustically
untreated lights,
vents or similar
penetrations penetrations
Wall Clips at 4mm minimum gap
each H-Stud
both sides of wall

Refer to Party Wall


System Table for wall
lining and insulation
GYPROCK SHAFT
LINER PANEL

20-40mm gap
each side of wall

GYPROCK OPTIMISED CORE PLASTERBOARDS 36


Flanking Paths via Wall
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

Stud frame wall system with min. PKAA031


75mm Bradford Gold batts

Fix end stud at GYPROCK


500mm maximum plasterboard as
vertical centres per system table

Timber or steel stud continuous wall system


with 75mm Bradford Gold Batts R1.5.
Plasterboard lining to flanking path side, as per
system table.
Intersecting stud wall system, with required
sound rating.

Tape and
Intersecting wall with set corners
required sound rating

SYSTEM N WALL LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 44/39

(b) 1 x 10mm Gyprock Superchek plasterboard. 48/43

CSR FP80 (c) 1 x 13mm Gyprock Soundchek plasterboard. 50/45

(d) 1 x 13mm Gyprock Fyrchek plasterboard. 50/45

(e) 1 x 16mm Gyprock Fyrchek plasterboard. 50/45

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION

Stud frame wall system with min.


75mm Bradford Gold batts PKAA031

GYPROCK
Steel Angle (75 x 75 x plasterboard as
0.7mm BMT) fixed to per system table
stud with panhead screw
at 600mm max. cts

Timber or steel stud continuous wall system


with 75mm Bradford Gold Batts R1.5.
Plasterboard lining to flanking path side, as per
system table. G
Intersecting stud wall system, with required
Intersecting wall with
sound rating. required sound rating Tape and
set corners

CSR Gyprock
Staggered Studs
and Clips

SYSTEM N WALL LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 50/42

(b) 1 x 10mm Gyprock Superchek plasterboard. 53/45

CSR FP82 (c) 1 x 13mm Gyprock Soundchek plasterboard. 54/46

(d) 1 x 13mm Gyprock Fyrchek plasterboard. 53/45

(e) 1 x 16mm Gyprock Fyrchek plasterboard. 54/46

GYPROCK OPTIMISED CORE PLASTERBOARDS 37


Flanking Paths via Wall
SYSTEM SPECIFICATION TYPICAL LAYOUT (Refer to detail Z207) ACOUSTIC
OPINION
Stud frame wall system with min.
75mm Bradford Gold batts
PKAA031
Fix end stud at 500mm
maximum vertical
centres
Tape and
set corners
Caulk gaps with
Gyprock sealant
Timber or steel stud wall with 75mm Bradford
Gold Batts R1.5. Intersecting wall with
required sound rating
Plasterboard lining to flanking path side, as per
system table.
Continuous
Intersecting wall system of masonry and bead of
sealant
separate stud framing, with required sound
rating.

10mm
Fix end stud to masonry nom. gap
at 500mm maximum from
vertical centres masonry
GYPROCK
plasterboard as to lining
per system table

SYSTEM N WALL LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 50/42

(b) 1 x 10mm Gyprock Superchek plasterboard. 52/44

CSR FP84 (c) 1 x 13mm Gyprock Soundchek plasterboard. 54/46

(d) 1 x 13mm Gyprock Fyrchek plasterboard. 53/45

(e) 1 x 16mm Gyprock Fyrchek plasterboard. 54/46

SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC


OPINION
Stud frame wall system with min.
75mm Bradford Gold batts
PKAA031
Sealant

GYPROCK
plasterboard as
per system table

Timber or steel stud wall system with 75mm


Fix end stud at
G Bradford Gold Batts R1.5.
Plasterboard lining to flanking path side, as per
500mm maximum
vertical centres

system table.
Intersecting stud wall system, with required
sound rating.

Intersecting wall with Tape and


required sound rating set corners

Sealant

SYSTEM N WALL LININGS Rw / Rw+Ctr


(a) 1 x 10mm Gyprock Plus plasterboard. 58/50
CSR FP86
(e) 1 x 16mm Gyprock Fyrchek plasterboard. 58/50

GYPROCK OPTIMISED CORE PLASTERBOARDS 38


Flanking Paths via Wall
SYSTEM SPECIFICATION TYPICAL LAYOUT ACOUSTIC
OPINION

PKAA031
Wall system insulation

Dampcourse

6mm Cemintel Wallboard barrier


full height of wall and fixed to stud
External masonry veneer and continuous stud
GYPROCK
wall system with 75mm Bradford Gold Batts plasterboard as
R1.5. per system table

Cemintel Wallboard barrier (as per table).


Plasterboard lining to flanking path side, as per
table. Intersecting wall with
required sound rating
Intersecting stud wall system, with required
sound rating.

Tape and
set corners

BARRIER
SYSTEM N WALL LININGS Nil 6mm Cemintel Wallboard
Rw / Rw+Ctr
(a) 1 x 10mm Gyprock Plus plasterboard. 38/29 58/49

(b) 1 x 10mm Gyprock Superchek plasterboard. 41/32 60/51

CSR FP90 (c) 1 x 13mm Gyprock Soundchek plasterboard. 45/37 60/52

(d) 1 x 13mm Gyprock Fyrchek plasterboard. 43/35 60/52

(e) 1 x 16mm Gyprock Fyrchek plasterboard. 45/37 60/52

GYPROCK OPTIMISED CORE PLASTERBOARDS 39


GYP500 ADDENDUM | OCTOBER 2015


THE RED BOOK

Health & Safety Contact Details


Information on any known health risks of our products and CSR Gyprock
how to handle them safely is on their package and/or the www.gyprock.com.au
documentation accompanying them. Additional information
is listed in the Material Safety Data sheet available from CSR Gyprock Sales Support
gyprock.com.au Telephone: 13 17 44
Facsimile: 1800 646 364

CSR DesignLINK Technical Support Service


Disclaimer Telephone: 1800 621 117
Facsimile: 1800 069 904
This guide is current at October 2015. CSR has taken all Email: designlink@csr.com.au
reasonable care in producing this guide, however CSR makes
no representations or warranties, express or implied, as to New South Wales and ACT
the accuracy, reliability or completeness of the guide, and 376 Victoria Street, Wetherill Park NSW 2164
disclaims all liability, direct or indirect (and whether or not
arising out of the negligence, default or lack of care of CSR) Queensland
for any loss or damage (whether foreseeable or not) suffered 768 Boundary Road, Coopers Plains QLD 4108
by the recipient or any other person arising out of, or in
Victoria
connection with, any use or reliance by any of them on the
277 Whitehall Street, Yarraville VIC 3013
guide. Liability which cannot legally be excluded is limited to
the maximum extent possible. South Australia
Information including acoustic and fire rating has been Lot 100 Sharp Court, Mawson Lakes SA 5095
sourced from recognised third parties and is current at the
Western Australia
time of printing. Systems, Standards and Building Codes are
21 Sheffield Road, Welshpool WA 6106
subject to change. It remains the responsibility of the building
designer to verify these systems are suitable for the particular Tasmania
requirements of any given project. To ensure the information is PO Box 61, Glenorchy TAS 7010
current, check the websites www.gyprock.com.au and www.
cemintel.com.au or contact CSR. Northern Territory
Cnr Stuart Hwy & Angliss St, Berrimah NT 0828
The guide is copyright CSR Limited (A.B.N 90 000 001 276) and its
related bodies corporate (CSR). Copyright 2011.

The following are trade marks of CSR Limited and are under license. CSR,
Gyprock, Gyprock Plus, Optimised Core, Supaceil, Soundchek,
Aquachek, Impactchek, Superchek, Fyrchek, FyrchekMR, ECO8,
Bradford, DesignLINK, Cemintel, SeminSeal, RendaLine, StrataWall,
ExpressWall.
GYP.BMS1113.1015