You are on page 1of 1



Evaporator

**
Compressor

Condensed water

Frigosorb
Model

FF-61
FF-81
FF-82
FF-122
FF-152
10,2
14,4
26,0
50,0

Capacity*
kg/h
5,4
Rotor

Expansion valve

3700
5200
9600
20900
Condenser

Dry Air Flow


m3/h
2300
Process air in

Dry air out

**
kW
3,3
5,7
8,5
14,4
32,9

Valid for inlet conditions 20C/ 60% RH. For other inlet conditions the capacity can
be calculated by using the correction factor from the diagram shown below.
Volume flow for density 1,20 kg/m3 .
Frigosorb
Used when it is not possible to duct the wet
air to ambient.
- The total energy consumption is around 1/3
compared with an ordinary sorption dehu-
midifier at 20C/60%RH.
- Only condensation, no wet air.
- Possible to achieve -10C dew-point in the
dehumidified room.
- Patented process.

Total power* Overall dimensions (mm)


L
1605
2000
2470
3000
3170
W
810
1030
1030
1610
1930
H
1350
1670
1670
2190
2310

Subject to change without notice.

Water content [g/kg]


K

Correction diagram for Frigosorb


The dehumidifying capacity is estimated Restriction line
as the nominal capacity from above, Standard units must only
Temperature C

multiplied by the factor K from the ] operate with process air


/kg
correction diagram. [kJ inlet in between these two
t out= t in+( K * 4) + 6 lpy lines .
ntha
E

Seibu Giken DST AB Representative:


Avestagatan 33, SE-163 53 Spnga, Sweden
E-post: info@dst-sg.com
GB 02.01

tel: +46-8 445 77 20


fax:+46-8 445 77 39
http://www.dst-sg.com

You might also like