Functions

BACnet Modbus LIOBFT I/O Controller


CEA709 MBus LOYTEC
KNX OPC COMPETENCE PARTNER

LIOB180/181/182/183/184
Datasheet #89024418

LIOB18x I/O Controllers are compact, programmable automation stations for


LonMark Systems with physical inputs and outputs.

LWEB
LonMark TP/FT10 Channel
LIOB18x I/O Controllers communicate via twisted pair over a TP/FT10 channel
in the LonMark System. LIOB18x I/O Controllers offer extended features such as
local alarming (SNVT_alarm and SNVT_alarm_2) and local scheduling.

LROC
Local Operation and Override
All LIOBI/O Controllers are equipped with an LCD display (128x64) with backlight
and jog dial for manual local operation and override. Device and data point infor
mation is displayed in text form and via graphical symbols.

Local I/O

LINX
CEA-709

&

LIOB
Made in Austria +~ -~ A B DO2 DO3 DO4 DO5 COM COM DO6 COM DO7 DO8 COM DO9
Made in Austria USB FT LPOW-2415A status
24 VAC/DC FT 6A 6A 6A 6A
status
Made in Austria

LOYTEC LIP-3ECTC LOYTEC LOYTEC LIOB-180 status

L-IP
www.loytec.com www.loytec.com
www.loytec.com

EIA709/IP router L-POW L-IOB


1 2 Power Supply I/O Controller
Ethernet 2 Input 85-265VAC Output UNIVERSAL IN DIGITAL IN 0-10V OUT
USB 2
FT
GND + 24VAC/DC PWR USB 1 Ethernet 1 NC B A N L 50/60 Hz 24VDC/15W UI1 GND UI2 UI3 GND UI4 UI5 GND UI6 UI7 GND UI8 DI1 GND DI2 AO1 GND AO2

IP-852

Gateways
Intranet
LonMark TP/FT-10
Internet
IP-852

IP-852

LVIS,L-STAT
Made in Austria
ETHERNET
+~ -~ DO2 DO3 DO4 DO5 COM DO6 COM DO7 DO8 COM DO9 Made in Austria +~ -~ A B DO2 DO3 DO4 DO5 COM COM DO6 COM DO7 DO8 COM DO9 +~ -~ A B DO2 DO3 DO4 DO5 COM COM DO6 COM DO7 DO8 COM DO9
LPOW-2415A status
24 VAC/DC 6A 6A 6A 6A
TRIAC TRIAC LPOW-2415A 24 VAC/DC FT 6A 6A 6A 6A 24 VAC/DC FT 6A 6A 6A 6A
Made in Austria status Made in Austria status Made in Austria status
LOYTEC LOYTEC LIOB-450 LOYTEC LOYTEC
www.loytec.com
www.loytec.com status
status
LOYTEC
www.loytec.com
www.loytec.com LIOB-150 status www.loytec.com LIOB-150 status

L-POW L-IOB L-POW L-IOB L-IOB


Power Supply I/O Module Power Supply I/O Module I/O Module
Input 85-265VAC Output UNIVERSAL IN DIGITAL IN 0-10V OUT Input 85-265VAC Output UNIVERSAL IN DIGITAL IN 0-10V OUT UNIVERSAL IN DIGITAL IN 0-10V OUT
N L 50/60 Hz 24VDC/15W UI1 GND UI2 UI3 GND UI4 UI5 GND UI6 UI7 GND UI8 DI1 GND DI2 AO1 GND AO2 N L 50/60 Hz 24VDC/15W UI1 GND UI2 UI3 GND UI4 UI5 GND UI6 UI7 GND UI8 DI1 GND DI2 AO1 GND AO2 UI1 GND UI2 UI3 GND UI4 UI5 GND UI6 UI7 GND UI8 DI1 GND DI2 AO1 GND AO2

LDALI
Features

Automation station with physical inputs and outputs SNVT-based interface for integration in
IEC611313 programmable with LLOGICAD the LonMark TP/FT10 channel
NV interface can be freely defined
Routers,NIC

128x64 graphic display with backlight


Local access to information about device status Up to 256 address table entries (ECS mode)
and data points in clear text and symbols LNS plugin for device configuration in the LonMark System
Manual operation using the jog dial Math objects to execute mathematical
Compliant with CEA709 and ISO/IEC14908-2 standard operations on data points
(LonMark System) LonMark Alarming with nvoAlarm (SNVT_alarm)
Interfaces

LonMark certified and nvoAlarm_2 (SNVT_alarm_2)


Local Scheduling
Accessories

buildings under control 73


Functions
LIOBFT I/O Controller

LIOB180/181/182/183/184
General Specifications
LWEB

Dimensions (mm) 107x100x75 (LxWxH), DIM015, DIM016, DIM017


Installation DIN rail mounting following DIN43880, top hat rail EN50022
Operating conditions 0C to 50C, 1090% RH, non condensing, degree of protection: IP40, IP20 (terminals)
Power supply 24VDC / 24VAC 10%
Programming LLOGICAD software (IEC611313)
LROC

Program cycle time Down to 10ms


Interface 1xLIOBFT or LonMark TP/FT10
Resource limits
Total number of data points 2000
Network variables (NVs) 200
Alias NVs 200
LINX

Address table entries 256 (non-ECS mode: 15)


LonMark Calendars 1 (25 calendar patterns)
LonMark Schedulers 10
LonMark Alarm Servers 1
LIOB

Connections (Local / Global) 200 / 0


Specifications LIOBFT I/O Controller (LIOB18x)
Type LIOB180 LIOB181 LIOB182 LIOB183 LIOB184
Power consumption 1.7W 1.7W 1.7W 1.7W 1.7W
2.6W (Relays on) 2.7W (Relays on) 2.5W (Relays on) 2.6W (Relays on)
Gateways

Universal Input (UI) 8 8 6 6 7


Digital Input (DI) 2 12 - - -
Analog Output (AO) 2 - 6 6 4
Digital Output (DO) 8 (4xRelay 6A, - 8 (8xRelay 6A) 5 (4xRelay 16A, 7 (5xRelay 6A,
4xTriac 0.5A) 1xRelay 6A) 2xTriac 0.5A )
LVIS,L-STAT

Digital Output specification Please refer to the General Input and Output Specification of LOYTEC devicesat the end of the LIOB
section for more details.
Differential Pressure Sensor - - - - 0500Pa
Order number Product description
LIOB180 LIOBFT I/O Controller: 8UI, 2DI, 2AO, 8DO (4xRelay 6A, 4xTriac 0.5A)
LIOB181 LIOBFT I/O Controller: 8UI, 12DI
LDALI

LIOB182 LIOBFT I/O Controller: 6UI, 6AO, 8DO (8xRelay 6A)


LIOB183 LIOBFT I/O Controller: 6UI, 6AO, 5DO (4xRelay 16A, 1xRelay 6A)
LIOB184 LIOBFT I/O Controller: 7UI, 4AO, 7DO (5xRelay 6A, 2xTriac 0.5A), 1 Pressure Sensor
LINXSTART-S Starter kit: 1xLIOB I/O Controller, 1xLPOW-2415A, and LSTUDIO software license
Routers,NIC

LLOGICADUSB IEC61131-3 programming tool, single license, includes USB dongle


LPOW2415A LIOBConnect power supply unit, 24VDC, 15W
LPOW2415B Power supply unit with power connector 24VDC, 15W
L-TEMP2 External temperature sensor (NTC10K) for use with LIOB Universal Inputs
Interfaces