You are on page 1of 21

How DNA-Blast Software can

bring benefits in Vibration control

By Dr Thierry BERNARD

An extract from Thierry BERNARD paper presented


TBT-COM-H-113-A @ EFEE Conference, 10-12 September 2003, Prague, Czech Republic
CONTENT

DNA-Blast Advanced Software for


Vibration control

Lafarge Contes case study


(Vibration control)

TBT-COM-H-113-A
DNA-Blast

Advanced Software
for Vibration control

TBT-COM-H-113-A
QUALITIR screen shots
DNA-Blast Software

TBT-COM-H-113-A
DNA-Blast Software
Vibration optimisation process
Input
Single Hole Seismic record
Mathematical Process
Seed wave simulation
Frequency analysis
+
X (N ) = x (t )e
j2 Nt
dt

Output
Iniation Sequence for
minimum vibration
FFT
Benefits
Regulation compliance
TBT-COM-H-113-A
DNA-Blast Software
Optimisation process
Delay Optimisation

Charge Optimisation
300
CHOIX DE LA CHARGE UNITAIRE

250

Vitesse
en mm/s
200
5.00

Charge (en kg)


4.00
3.50
150 3.00
2.50
2.00

100 1.50
1.00
0.75

Single Hole Trace


0.50
50

0
75

5
50

25

00

75

50

25

00

75

50
0
15

22

30

37

45

52

60

67

75

82

90

97

10

12

12

13

14

15

15

16
11
Distance (en m)

DNA Blast Engine

Objective selection

Blast Seismic
Trace
Drilling pattern
Blast design
adjustment
TBT-COM-H-113-A
DNA-Blast Software

Lafarge Contes case study


about Vibration control

TBT-COM-H-113-A
DNA-Blast Software
Case study : Lafarge Site
Lafarge quarry in the South of France

Located in Contes village


TBT-COM-H-113-A 20 km far from Nice
DNA-Blast Software
Case study : Lafarge Site

LAFARGE
CIMENTS

Usine de Contes
TBT-COM-H-113-A Carrire de Pont de Peille
DNA-Blast Software
Case study : Lafarge Site

TBT-COM-H-113-A
DNA-Blast Software
Case study : Lafarge Site

TBT-COM-H-113-A
DNA-Blast Software
Case study : Typical production blast
Borehole diameter : 89 mm
Bench height : 10 & 19 m
Burden 3 m / Spacing 3.5 m
2 to 4 decks per hole
Average charge per delay : 19 kg

TBT-COM-H-113-A
DNA-Blast Software
Case study : Typical overburden blast
Borehole diameter : 89 mm
Bench height : 6 to 10 m
Burden 3 m / Spacing 3.5 m
2 to 3 decks per hole
Average charge per delay : 6 to 16 kg

TBT-COM-H-113-A
DNA-Blast Software
Case study : Vibration statement
PPV evolution
Important reduction through years

PPV / Years
PPV (mm/s)

R2 = 0.2951
Average PPV Divided by 6
91 92 92 93 94 95 96 97 98 99 00 01 02

TBT-COM-H-113-A
DNA-Blast Software
Case study : Complains history
100 %

70 %

Complains

Complains
30 %
PPV

Complains
PPV

<5 %
PPV

PPV
C
1991 1992 1994 2002
TBT-COM-H-113-A
DNA-Blast Software
Case study : Vibration history vs Complains

In 2002, there is only one or two complaining phone call per year

TBT-COM-H-113-A
DNA-Blast Software
Case study:Vibration history vs Initiation systems

TBT-COM-H-113-A
DNA-Blast Software
Case study : Charge per Delay Optimisation

TBT-COM-H-113-A
Electronic Detonators Used
DELTADET system

TBT-COM-H-113-A
DNA-Blast Software
CONCLUSION
DNA-Blast software gives the
following benefits to lafarge:
Decrease PPV by 6 that suppressed
neighbours complains about
vibrations and consequently
allowed Lafarge to extend the site
Optimise the use of electronic
detonators that allowed to increase
the charge per delay and gave to
Lafarge a cheapper cost per ton.

TBT-COM-H-113-A
Advanced Software
for
a Million Dollar Benefit
www.tbtech.fr

TBT-COM-H-113-A

You might also like