Professional Documents
Culture Documents
PAGE TAB
FILTER MEDIA
Filter cartridges (Wound) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14
1
Filter cartridges (Melt blown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Filter cartridges (Pleated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-19
Filter sleeves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Carbon cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-23
Photoprocessing cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Stainless steel cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Lead removal cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Industrial cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-30
2
METERING & AIR OPERATED DIAPHRAGM
PUMPS, PULSATION DAMPENERS,
COMPRESSED AIR FILTERS
Metering pumps (Flow rates to 25 U.S. GPH) . . . . . . . . . . . . . . . . . . . . 31-34
AOD pumps (Flow rates to 150 U.S. GPM or 95 PSI) . . . . . . . . . . . . . . 35-40
Pulsation dampeners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Compressed air lters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-45
DRUM PUMPS
Electric and air powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-54
3
Batch control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55-57
Industrial and Sanitary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58-64
Hand Powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-67
Chemical resistance chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68-71
INSTRUMENTATION &
CONTROLS
pH / ORP meters, controllers, recorders, monitors . . . . . . . . . . . . . . . . 72-79
4
Conductivity controller / monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80-82
Electroplating brightener controllers and totalizers . . . . . . . . . . . . . . . . 83-84
Flow instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85-88
HEATERS
Heaters and controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98-109
6
ACCESSORIES
Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
7
Plastic ttings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111-114
Hose kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Clamps and oor mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Skimmer assembly and oating balls . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
VERTICAL PUMPS
Plastic
9
Cantilever style (Flow rates to 400 U.S. GPM or 175 ft. TDH) . . . . . 132-144
Magnetic coupled (Flow rates to 90 U.S. GPM or 150 ft. TDH) . . . . . . 145-148
Bearing style (Flow rates to 370 U.S. GPM or 130 ft. TDH) . . . . . . 149-156
Metallic (Flow rates to 180 U.S. GPM or 90 ft. TDH) . . . . . . . . . . . . . . . 157-159
Collection and pumping stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160-162
HORIZONTAL PUMPS
(Direct Drive)
Plastic (Flow rates to 1200 U.S. GPM or 167 ft. TDH) . . . . . . . . . . . . . 163-179
10
Metallic (Flow rates to 420 U.S. GPM or 108 ft. TDH) . . . . . . . . . . . . . 180-186
MAGNETIC
COUPLED PUMPS
Plastic (Flow rates to 255 U.S. GPM or 150 ft. TDH) . . . . . . . . . . . . . . 187-209
11
Metallic (316 SS) (Flow rates to 160 U.S. GPM or 79 ft. TDH) . . . . . . . . . . . 210-211
Metallic (lined) (Flow rates to 330 U.S. GPM or 320 ft. TDH) . . . . . . . . . . . 212-215
TABLE OF CONTENTS
PAGE TAB
SELF-PRIMING PUMPS
Centrifugal (Flow rates to 280 U.S. GPM or 120 ft. TDH) . . . . . . . . . . . 216-228
12
FILTER CHAMBERS
Chambers for a variety of uses & Sizing. . . . . . . . . . . . . . . . . . . . . . . . . 229-231
13
Non-metallic solution contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232-266
Metallic solution contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267-278
FILTRATION SYSTEMS
(Plastic with vertical pumps)
Flow rates to 7,000 GPH (Admiral) . . . . . . . . . . . . . . . . . . . . . . . . . . . 279-281
14
Flow rates to 600 GPH (Sub-Admiral) . . . . . . . . . . . . . . . . . . . . . . . . . . . 282-284
Flow rates to 1,000 GPH (Admiral EL) . . . . . . . . . . . . . . . . . . . . . . . . . . 285-286
Flow rates to 4,200 GPH (Admiral EOS) . . . . . . . . . . . . . . . . . . . . . . . . 287-288
Flow rates to 10,000 GPH (Admiral EHJ) . . . . . . . . . . . . . . . . . . . . . . . 289-290
Flow rates to 3,400 GPH (Open bag) . . . . . . . . . . . . . . . . . . . . . . . . . . . 291-292
FILTRATION SYSTEMS
(Plastic or metal with
horizontal pumps)
15
Flow rates to 345 GPH (Labmaster) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293-294
Flow rates to 600 GPH (Labmaster LX) . . . . . . . . . . . . . . . . . . . . . . . . . 295-298
Flow rates to 4200 GPH (Space-Saver) . . . . . . . . . . . . . . . . . . . . . . . . 299-302
Flow rates to 1,200 GPH (Space-Saver SX) . . . . . . . . . . . . . . . . . . . 303-306
Flow rates to 3,200 GPH (Space-Saver SM) . . . . . . . . . . . . . . . . . . . 307-310
Flow rates to 6,000 GPH (Space-Saver J) . . . . . . . . . . . . . . . . . . . . . 311-314
Flow rates to 6,500 GPH (Super Space-Saver) . . . . . . . . . . . . . . . . . . . 315-317
Flow rates to 10,000 GPH (Guardian) . . . . . .. . . . . . . . . . . . . . . . . . . . . 318-321
Flow rates to 8,500 GPH (Guardian disc) . . . . . . . . . . . . . . . . . . . . . . . . 322-323
Flow rates to 21,000 GPH (Mega-Flo) . . . . . . . . . . . . . . . . . . . . . . . . . . . 324-327
Flow rates to 19,000 GPH (Sentry ltration/purication systems) . . . . . . 328-331
Flow rates to 9,000 GPH (Series M metallic systems) . . . . . . . . . . . . 332-333
Flow rates to 9,000 GPH (Knight metallic systems) . . . . . . . . . . . . . . . 334-336
AUTOMATIC PERMANENT
MEDIA FILTRATION SYSTEMS
Flow rates to 30,000 GPH (Titan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337-340
16
Flow rates to 12,000 GPH (Excel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341-342
TABLE OF CONTENTS
PAGE TAB
GRAVITY & PRESSURE
FILTRATION SYSTEMS
Automatic gravity systems (1.5 to 113 sq. ft.) Series DF . . . . . . . . . . 343-346
17
Roll-A-Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Cartridge / bag system (Flow rates to 1,800 GPH) Series CB . . . . . 348-349
Recessed plate lter press (0.6 to 50 cu. ft. capacity) . . . . . . . . . . . . . 350-351
Laboratory lter press (.01 and .02 cu. ft. capacity) . . . . . . . . . . . . . . . 352
OIL FILTRATION
Oil Filtration and Reconditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353-356
18
CARBON PURIFICATION
Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357-358
19
Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359-360
REFERENCE MATERIALS
General chemical resistance guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372-375
22
Chemical resistance guide for media. . . . . . . . . . . . . . . . . . . . . . . . . . . . 376-379
Bulletin index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380-381
Product index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382-383
Terms & conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
Registered trademarks:
Cellosolve - Union Carbide; Corzan - B. F. Goodrich Co.; Dacron, Delrin, Freon, Orlon, Teon, Tefzel - DuPont; Hypalon, Kalrez,
Viton, Neoprene - DuPont Dow Elastomers; Derakane, Saran - Dow Chemical; Halar - Ausimont; Hastelloy - Haynes, Interna-
tional; Kynar - Atochem; Lexan, Noryl - General Electric; Norprene - Norton Co.; Pyrex - Corning, Inc.; Rulon - Dixon; Ryton
- Phillips Chemical; Bakelite - Georgia Pacic Resins, Inc.; Santoprene - Advanced Elastomer Systems, L.P.; Fluorosint - DSM
Engineering Plastic Products; Geolast - F. C. Witt Assoc., Inc.
Safety First / An Ounce of Prevention
Flammable solvents are often purchased in bulk and transferred the liquid were allowed to splash around during movement of
manually or with motor driven pumps. Care must be taken to the container. Therefore both containers must be satisfactorily
neutralize static electricity which may rest as a potential in the grounded, and then each of the containers must be bonded,
storage tank, as well as that which may rest in the receiving tank. that is connecting the ground wire from tank to tank so that the
The potential of such would, of course, be greatly increased if potential static electricity is now equalized.
In addition to the proper use of bonding and grounding cables, Operator should have checked the instruction manual and fol-
when motorized pumps are used to transfer flammables and lowed procedures as set forth by the manufacturer to ensure
combustibles, explosion-proof or air driven pumps should be that the cover of the pressure vessel was securely tightened.
used. Explosion-proof electric or air motors are often wired Operator could also have prevented bodily injury if he was
and/or enclosed in such a way that no sparks can be emitted protected with adequate clothing, which is fabricated to resist
from the motor casing - otherwise sparks from the motor could such liquids.
cause the flammable liquid to flash or explode.
FILTER MEDIA
1
M-109K-2
BAG FILTERS
A Bag Filter is shaped like a bag or sack with only the top side open. The bag filter is
made of a variety of materials including needled felt and polypropylene, just to name
a few. Flow is from inside through the porous material to the outside. Bag filters are
available in a variety of micron ratings from 5 to 100. Bag filters are best used to cap-
ture large contaminates, or applications with high contaminate loading. One of the
best applications for bag filters is ahead of cartridge filters reducing the loading and
increasing life.
1
FILTER CARTRIDGES M-109K-2
FEATURES
Full 2" O.D. provides 3.5 square feet of
filter area per 10" length
Precision wound
Micron accuracy tested
Wide selection of media material, car-
tridge lengths and micron ratings
Excellent chemical resistance
Fits any D.O.E. style vessel
BENEFITS
1
MAXI-DEPTH WOUND FILTER CARTRIDGES cont'd M-109K-2
NOMINAL NOMINAL
MEDIA MATERIAL CORE MATERIAL CORE COVER EXTENDED CORE
MICRON RATING LENGTH
1 B - Unbleached cotton P - Fibrillated polypropylene 4 (3-7/8") U - Polypropylene None - No symbol None - No symbol
3 C - Bleached cotton (Purefybe) 6 (5-7/8")
5 CU - Carbon & Polypropylene R - Rayon 8 (7-7/8") S - 316SS C - Cover ECU - Polypropylene
10 G - Glass ber (Unbaked) U - Polypropylene (Wound & 9.8 (9-3/4") compatible
15 10 (10")
H - Hi-Perf Polyspun) A - 304SS with media ECS - 316 SS
20 19.8 (19-3/4")
30 K - Polyester W - Potable water 20 (20")
50 N - Nylon polypropylene 29.8 (29-3/4") T - Tinned Steel EPS - One piece
75 O - Orlon 30 (30") polypropylene
99 (100) Orlon is a registered trademark of DuPont. 40 (40") spring & top seal
10
1
MAXI-DEPTH WOUND FILTER CARTRIDGES cont'd M-109K-2
HI-PERF
FOR CHROMIC / SULFURIC / NITRIC ACIDS
HI-PERF filter cartridges are constructed of proprietary materials which are specifically
designed for chrome plating applications, nitric and sulfuric acid solutions. They are equally well
suited for aggressive solvents and bases.
MICRON NOMINAL STOCK
MODEL RETENTION LENGTH STATUS
RATING
05H10U 10 S
05H20U 20 N/S
5
05H30U 30 N/S
05H40U 40 N/S
15H10U 10 S
15H20U 20 N/S
15
15H30U 30 N/S
15H40U 40 N/S
30H10U 10
30H20U 20
30
30H30U 30 N/S
30H40U 40
50H10U 10
50H20U 20
50
50H30U 30 N/S
50H40U 40
99H10U 10
99H20U 20
100
99H30U 30 N/S
99H40U 40
GLASS FIBER
1
VALUWOUND POLYPROPYLENE DEPTH CARTRIDGES M-109K-2
FEATURES
High quality polypropylene polypropylene core
Precision wound
Micron accuracy tested
Available 1 - 100 micron rating
Nominal 23/8" O.D.
TABLE B TABLE C
CORE COVER
TO SUBSTITUTE OTHER CORE MATERIAL
Replace the last letter "U" or "T" of the Model
Number with A, S, U or T ADD "C" AFTER CORE
MATERIAL LETTER IN
MODEL NUMBER
TINNED STEEL -T TO:
MATERIAL
S - 316SS TABLE D
A - 304SS EXTENDED CENTER CORE
U - Polypro.
ADD TO
POLYPROPYLENE -U TO: MATERIAL
MODEL NO.
NOMINAL NOMINAL
MEDIA MATERIAL CORE MATERIAL CORE COVER EXTENDED CORE
MICRON RATING LENGTH
1 B - Unbleached cotton P - Fibrillated polypropylene 4 (3-7/8") U - Polypropylene None - No symbol None - No symbol
3 C - Bleached cotton (Purefybe) 6 (5-7/8")
5 CU - Carbon & Polypropylene R - Rayon 8 (7-7/8") S - 316SS C - Cover ECU - Polypropylene
10 G - Glass ber (Unbaked) U - Polypropylene (Wound & 9.8 (9-3/4") compatible
15 10 (10")
H - Hi-Perf Polyspun) A - 304SS with media ECS - 316 SS
20 19.8 (19-3/4")
30 K - Polyester W - Potable water 20 (20")
50 N - Nylon polypropylene 29.8 (29-3/4") T - Tinned Steel EPS - One piece
75 O - Orlon 30 (30") polypropylene
99 (100) Orlon is a registered trademark of DuPont. 40 (40") spring & top seal
13
1
MAXI-WIND 4" DIAMETER FILTER CARTRIDGES M-109K-2
w/POLYPROPYLENE CORE
Wound of bers free of "sizing" and yarn "nish" substances
MICRON
MODEL RETENTION
RATING
5P9.8U4 5
10P9.8U4 10
25P9.8U4 25
50P9.8U4 50
99P9.8U4 100
Minimum order carton of 10.
Purefybe is an all polypropylene cartridge wound as iron and aluminum hydroxides which can be dissolved
of bers free of extractables. It is designed for ltration with acids.
of electroforming, precious metals and all other plating Enter a blanket order with scheduled releases to earn
solutions or applications requiring organic-free lter media. the lowest quantity price, plus gain "Just in time" delivery.
It is also recommended for gelatinous precipitates such
1
POLYSPUN DEPTH FILTER CARTRIDGES M-109K-2
SERFILCO POLYSPUN depth filter cartridges are melt-bonded media and excellent flow characteristics
individually packaged to provide 1 to 75 micron high present a filter cartridge that meets the tough require-
purity filtration and an organic free, pure polypropylene ments of today's technology.
media. Their outstanding chemical resistance, fiber free
MICRON 1 5 10 20 30 - 75
PRESSURE
5 2 1 .7 .5
DROP (PSI) **
SERFILCO POLY-SERF pleated filter car tridges POLY-SERF cartridges provide efficient particle re-
are composed of continuous polypropylene microfibers moval from aqueous and non-aqueous solutions with
self-bonded by a unique process that controls media outstanding contaminant holding capacity. They provide
uniformity and density. excellent chemical resistance, high flow rates at low
pressure drop and can be washed for reuse.
MICRON MICRON
MODEL RETENTION LENGTH MODEL RETENTION LENGTH
RATING RATING
PL-U1U10U 10" PL-U25U10U 10"
PL-U1U20U 20" PL-U25U20U 20"
1 25
PL-U1U30U 30" PL-U25U30U 30"
PL-U1U40U 40" PL-U25U40U 40"
PL-U5U10U 10" PL-U50U10U 10"
PL-U5U20U 20" PL-U50U20U 20"
5 50
PL-U5U30U 30" PL-U50U30U 30"
PL-U5U40U 40" PL-U50U40U 40"
PL-U10U10U 10"
PL-U10U20U 20"
10
PL-U10U30U 30" SUPERIOR FLOW CHARACTERISTICS
PL-U10U40U 40" AT LOW PRESSURE DROP.
WATER FLOW RATE AT
* Minimum order quantity 5.
10 GPM (38 LPM) PER 10" LENGTH
** 40 per carton - 10" PSID PRESSURE
20 per carton - 20", 30", 40" MICRON
DIFFERENTIAL
1 0.4
NOTE: For FDA acceptable materials add -W to end of 0.3
5
Model Number. Minimum quantity 30. 10 0.2
PLEATED 17
FILTER CARTRIDGES
1
M-307X-2
POLYESTER
Chemical compatibility
including solvents, acids and bases
A pleated polysulfone membrane whose pore bonding. Standard end gaskets (DOE) and 222 "O"-
size decreases gradually from 10 to 20 micron on rings (SOE) are ethylene propylene.**
the upstream side to the absolute rated 0.1, 0.2 or Each 10" length has 5 sq. ft. (.51 sq. m) of
0.45 micron on the downstream side. The mem- filter area and will hold more than 150 grams of
brane provides its own cast-in pre-filter to prevent Arizona fine test dust. Cartridge will withstand
premature loading and extend service life. Includes water at 200oF (93C) for extended periods without
pleated polypropylene support and drainage layers, degradation. Maximum recommended differential
end caps, center core and protective outer cage. pressure, 50 PSID (3.5 kg/cm2D). Cartridge is 2.6"
Cartridge is free of all organics and electrochemical diameter.
FLOW
MODEL ABSOLUTE PER 10" @
FLAT GASKETS 222 "O"-RINGS MICRON 1.0 PSID
DOE SOE RATING GPM LPM
PL-UPS.1x * UL PL-UPS.1x * UL-2 0.1 2 7.6
PL-UPS.2x * UL PL-UPS.2x * UL-2 0.2 4 15
PL-UPS.45x * UL PL-UPS.45x * UL-2 0.45 6 23
* Length. Specify 10", 20", 30" or 40".
** For Viton elastomers, substitute UV for UL in Model No.
19
TRI-PLEATED
FILTER CARTRIDGE
1
M-207T-2
All polypropylene
with EPDM or Viton elastomers
Chemical compatibility
including solvents, acids and bases
Absolute rated
1.0, 2.0 and 5.0 micron
Organic-free
no sizing or anti-static agents
Economical alternative
to disc-type filter
FEATURES
Interchangeable
Sleeve cartridges are interchangeable with any regular
cartridge of corresponding length and diameter.
Easy to clean
Reusable
BENEFITS
The SERFILCO Sleeve-Type Filter Car tr idge may be Each filter car tr idge consists of a polypropylene top
used uncoated or with filter aid or filter aid with carbon. As the and bottom seat, a polypropylene woven fabric sleeve, a poly-
filters become dirt-laden, they may easily be backwashed, propylene support mesh, a CPVC support column, EPDM
or the sleeves may be removed, rinsed or laundered and put "O"-rings and a vinyl coated spring to assure good sealing.
back into service.
These filter cartridges can be quickly and easily assembled
This unique design of filter car tridges will not only help and re-assembled no tools are required.
reduce operating costs, but will simplify and speed up any
pre-coat type filtration process.
CLEANABLE SLEEVE CARTRIDGES
SLEEVE SURFACE FOR CHAMBER STYLE REPLACEMENT
LENGTH AREA SLEEVE ONLY
SINGLE COLUMN MULTIPLE COLUMN
X SQ. FT.
2-1/2" DIA. PRICE CODE NUMBERS.
PLATING
1
M-305V-2
WT. OF CTN.
MODEL
2-3/4" nominal dia. x 9.75" long ACM9.8 CARB. QTY.
2-3/4" nominal dia. x 10" long ACM10 ACM9.8 5 oz. 20
2-3/4" nominal dia. x 20" long ACM20
ACM10 5 oz. 20
ACM20 10 oz. 12
CARBO-FYNE P
Powdered carbon lter
Cartridge contains high purity, pre-washed operating temperature 150 oF (66 oC). For 3 U.S.
sulfur-free, pulverized activated carbon with GPM (11 LPM) continuous or 1.5 U.S. GPM
7 micron depth filtration for long life. All non- (5.7 LPM) batch transfer treatment per each
metallic with polyethylene end caps, polyole- 10" length.
fin gold net and polypropylene core. Maximum
WT. OF CTN.
MODEL
CARB. QTY.
2-3/4" nominal dia. x 4" long C4P C4P 1.6 oz. 60
2-3/4" nominal dia. x 6" long C6P
C6P 2.4 oz. 30
2-3/4" nominal dia. x 10" long C10P
2-3/4" nominal dia. x 20" long C20P C10P 4 oz. 30
2-3/4" nominal dia. x 30" long C30P C20P 8 oz. 30
2-5/8" nominal dia. x 9.75" long C9.8P C30P 12 oz. 30
C9.8P 4 oz. 30
CARBO-FYNE PE
Powdered carbon lter electronics
Designed for purifying plating solutions used net and polypropylene core. Cartridge contains
for electronics, memory discs, semi-conductors, high purity, pre-washed sulfur-free, pulverized
etc. where solutions are to be free of organics and activated carbon with 2 micron depth filtration
particles larger than two micron. All non-metal- for long life. Maximum operating temperature
lic with polyethylene end caps, polyolefin blue 150oF (66oC). Flow rate 1.5 U.S. GPM (5.7 LPM).
WT. OF CTN.
MODEL
CARB. QTY.
C10PE 6 oz. 30
GRANULAR ACTIVATED CARBON ACTIVATED WITH STEAM FOR HIGH ADSORPTION CAPACITY
Available in 10 and 50 pounds drums
SPRING MINI-CANISTER P
LOADED
ABS/PVC canister with Saran and screens To order granular carbon, refer to Bulletin R-102.
To order resin, refer to Bulletin R-208.
Features a twist-off end cap which permits 3" DIA. WEIGHT OF
MODEL
easy filling with carbon or resin (not included). x LENGTH CARBON
End cap screens retain contents. Maximum
4ABS 4" 3 oz.
operating temperature is 160F (71C). Non- 6ABS 6" 7 oz.
standard lengths available. Flow rates to 10ABS 10" 14 oz.
2 U.S. GPM (7.6 LPM) per each 10" length. 20ABS 20" 33 oz.
For SERFILCO Series 'L' chambers or may 30ABS 30" 52 oz.
be ordered with hose adapter for connection 40ABS 40" 71 oz.
CPVC HOSE to filter system discharge hose.
ADAPTER
For Mini-Canister w/CPVC 1/2" hose adapter, add -H.5 to Model . . . Add $5.75
For Mini-Canister w/CPVC 3/4" hose adapter, add -H.75 to Model . . . Add $5.75
CARBONEX P
3 in 1 Granular carbon filter
Porous polyethylene outer shell which serves on a polypropylene core. Maximum operating
as a 50 micron prefilter houses granular activated temperature 150F (66C). EPDM gaskets. Flow
99.5+% sulfur-free carbon and encases a 3 rate 2 U.S. GPM (8 LPM) per each 10" length.
micron polypropylene wound polishing filter
WEIGHT OF CARTON.
2-3/4" nominal dia. x 10" lg. CU10P MODEL CARBON
2-3/4" nominal dia. x 20" lg. CU20P
QUANTITY.
2-3/4" nominal dia. x 30" lg. CU30P CU10P 7 oz. 25
CU20P 14 oz. 12
CU30P 21 oz. 12
CARBO-WIND P
3 in 1 Granular carbon filter
Polypropylene outer winding ser ves as on a polypropylene core. Maximum operating
a 50 micron prefilter which houses granular temperature 200oF (93oC). Flow rate 2 U.S.
activated 99.5+% sulfur-free carbon followed by GPM (9.5 LPM) per each 10" length.
a 3 micron polypropylene wound polishing filter
WEIGHT OF CARTON.
MODEL CARBON QUANTITY.
2-3/4" nominal dia. x 10" lg. CU10UP
2-3/4" nominal dia. x 20" lg. CU20UP CU10UP 5 oz. 20
CU20UP 10 oz. 12
WATER
1
M-310C
ULTRA-CARB W
CARBO-FYNE W
MAXI-CARB W
CARBONEX W
CARBO-WIND W
MINI-CANISTER W
SPRING
LOADED
Refillable for granular carbon
Features a twist-off end cap which permits easy lling with
carbon or resin (not included). End cap screens retain con-
tents. Carbon is used to remove organic
substances which cause taste, odor and WEIGHT OF CARTON
color in water. Maximum operating tem- MODEL
CARBON QUANTITY
perature is 160F (71C). Non-standard
9ABS 9-3/4" 13 oz.
lengths available. Flow rates to 2 U.S. 19ABS 19-3/4" 32 oz.
GPM (7.6 LPM) per each 9-3/4" length.
ABS / PVC canister. Saran end screens.
Designed to t SERFILCO GPO and GSO chambers.
1
M-309D-2
* Length: Specify 10", 20" or 30" * Length: Specify 10", 20" or 30"
** Flow per 10" length at 2 P water. ** Flow per 10" length at 2 P water.
Maximum recommended is 30 GPM per cartridge. Maximum recommended is 25 GPM per cartridge.
OPTIONAL OPTIONAL
MAX. CHANGE 'L' MAX. CHANGE 'B'
GASKETS TEMP. in MODEL to GASKETS TEMP. in MODEL to
Viton 400 F V Viton 400 F V
Consult Sales Department for flow at other viscosities.
26
LEAD REMOVAL
1
CARTRIDGES M-308A
The inert molecular sieve construction of the ATS ma- The CLR Series has been evaluated against the test
terial internally and irreversibly locks onto any lead in protocol as outlined in NSF standard #53 by a certied
solution reducing the concentration to below U.S. EPA third-party laboratory. The results show that a standard
guidelines with a very short contact time. The ATS mate- 9" cartridge at 0.75 GPM will effectively reduce a 150
rial works well in hard water as well as in the presence of PPB spiked feed of lead to less than 10 PPB for 4000
iron, manganese, magnesium and calcium ions. It func- gallons in a low pH, low alkalinity solution and for 3000
tions on the principle of chemically "absorbing" the lead gallons in a high pH, high alkalinity solution.
ions rather than insolubilizing the lead and will not put
aluminum, copper or zinc ions into the treated water.
TO ORDER
MODEL GPM
Carton quantity: 12
CLR10W .5 - 1
2" diameter x 9" or 20" long.
CLR20W 1-2
FILTER CARTRIDGES 27
INDUSTRIAL
1
M-206T -2
For all types of oil filtering fuel, lube, hydraulic, cutting oils,
quench, transformer, dielectric & coalescing
Has extremely high flow rate. Performs well on filtration of water and oil. Typical
applications: For detergent, straight mineral and residual fuel oils. Water, glycol-water
synthetics or oil-water emulsions. PL718 has a metal jacket and center core with vellumoid
seals. PL310 has exposed pleats and Buna-N seals. Maximum temperature: 250oF.
MODEL
MICRON
2-1/8" I.D x 6" x 18" lg.
PL718-1 1
PL718-5 5
PL718-10 10
PL718-20 20
PL718-30 30
6 & up shipped full carton quantity (6/ctn.)
PL718 PL310 Quantity 1-12 F.O.B. Northbrook, Illinois 18 & up F.O.B. East Coast
SERFILCO
PLEATED PAPER CAR- 1-1/8" I.D x 2-5/8" x 10" lg. MICRON
TRIDGES PL310-1-11B 1
PL310-5-11B 5
PL310-10-11B 10
For cartridges of other 30 & up shipped full carton quantity (30/ctn.)
dimensions or cross Quantity 6-29 F.O.B. Northbrook, Illinois 30 & up F.O.B. East Coast
reference to other
brands, request
Bulletin M-205 and 1-5/8" I.D. x 4" x 36" lg. MICRON
Price Sheet M-204. PL436-2-4 2
PL436 has exposed pleats, PP core, plastisol end caps.
F.O.B. Northbrook, Illinois
Has a relatively high flow rate and dirt holding capacity. Retains resiliency and will
absorb water. Typical applications: Hydraulic, fuel, quench and diesel engine lube oils;
machine tool coolants, solvents, etc. Spun wound all new cotton thread.
MODEL
(MATERIAL) MICRON
C718
10
(Cotton/stl. core)
C718
COTTON BAG
F718 (2-1/8" I.D. x 7" x 19-1/4" lg.)
Bag type to replace:
CFD 6825, Fram C727, Keene LEB 718,
Velcon CO-719B
F718-4 (2-1/4" I.D. x 6-3/4" x 18-1/4" lg.)
Bag type with permanent center tube to replace:
Velcon CO-718B
METAL CANISTER
F718-C (2-1/8" I.D. x 6-3/4" x 18" lg.)
Canister type to replace:
Banner FCC 18701, CFD 4603, Fram C766-1,
Hilco FFC-00, H-A 718-FEP, Keene D196,
LE 718, Velcon CO-718-CC
MODEL DESCRIPTION
4 & up shipped full carton quantity.
F718-C METAL CANISTER Quantity 1-3 F.O.B. Northbrook, Illinois
COTTON BAG 4 & up F.O.B. East Coast.
F718
F718-4 COTTON BAG
EDM 29
FILTER CARTRIDGES
1
M-209A
SPECIFICATIONS
OUTSIDE INSIDE OVERALL OUTSIDE
PART NUMBER DIA. DIA. LENGTH SEAL CORE BODY BONDING COMMENT
PL407-5-2 4" 1-1/16" 7-1/2" Vellumoid Steel Plated PVC Agietron
PL614-5 6" 3-1/2" 14-1/2" Buna N Steel Plated PVC Japax Facet CH 57
EDM
PL614-5-1 6" 1" 14-5/8" Grommet Steel Plated PVC Facet C44 (w/handle)
PL614-5-1A 6" 1" 14-5/8" Grommet Plated Plated PVC Facet C44P (w/handle)
Charmilles Agietron
PL614-5-2 6" 1-1/4" 14-5/8" Grommet Steel Plated PVC Facet C54 (w/handle)
PL614-5-2A 1-1/4" 14-5/8" Grommet Steel None PVC Facet C54 & CH54PL
6" (w/handle)
PL614-5-2P 1-1/4" Plated Plated PVC Sodick Charmilles Facet
6" 14-5/8" Grommet CH56PL (w/handle)
PL614-5-3 6" 1-1/4" 14" Cork Steel Plated PVC Japax
PL614-5-5 6" 3-1/2" 14-1/2" Buna N Steel None PVC Japax Facet C744
PL614-5-6 6" 3-1/2" 14-1/2" Buna N Plated None PVC Japax
PL614-5 PL614-5-16 6" 1-1/4" 14-5/16" Cork Steel Plated PVC Japax
PL614-5-16A 6" 1-1/4" 14-5/16" Cork Plated Plated PVC Japax
PL614-5-16C 6" 1-1/4" 14-5/16" Cork Steel None PVC Japax
Japax (w/handle)
PL614-3-20 6" 1-1/4" 14" Cork Plated None PVC 3 micron
PL614-5-20 6" 1-1/4" 14" Cork Plated None PVC Edmas WF-8 (w/handle
Japax (w/handle)
PL614-5-20A 6" 1-1/4" 14" Cork Plated None PVC
Water Resistant Paper
PL614-5-20C 6" 1-1/4" 14" Cork Steel None PVC Japax (w/handle)
PL614-5-26 6" 3-1/2" 14-1/2" Buna N Plated None Epoxy Deionized Water Only
PL614-5-44A 6" 1-1/4" 14" Vellumoid Plastic None Epoxy Epoxy Ends
C718 6-1/2" 2-1/8" 18" Vellumoid Steel Sock N/A Depth-Cotton Fiber
Clay (Fuller's Earth)_
F718-C 6-1/2" 2-1/8" 18" Cork Fiber Plated PVC Oil Acid REmoval
Charmilles Sodick Elox
PL718-5FP 6" 2-5/8" 18" Vellumoid Steel Plated PVC Excello Spartcatron
PL718-5-5A Vellumoid Steel Plated PVC Sodic Eltee Pulsitron
6" 2-1/8" 18"
Spartcatron (w/handle)
PL614-5-5
PL718-5-14BP 6" 2-5/8" 17-7/8" Buna N Plated Plated PVC Deionized Water Only
C815-2 7-1/2" 1-1/2" 15-1/8" Vellumoid Steel Sock N/A Depth-Cotton Fiber
30
1
EDM FILTER CARTRIDGES continued M-209A
Designed for both wire EDM (D.I. water) Reduce downtime & extend the life of
and Ram/sinker EDM (oil) machines. Meets your deionized water or dielectric oil.
or exceeds OEM specifications. Eliminate hot spots & arcing caused by
High efficiency filtration for removal of contaminated dielectric fluids.
harmful spark erosion residue resulting in Water resistant paper is phenolic resin
improved fluid flushing, cooling & insulat- impregnated and oven cured.
ing properties.
SPECIFICATIONS
OUTSIDE INSIDE OVERALL OUTSIDE BONDING COMMENT
PART NUMBER DIA. DIA. LENGTH SEAL CORE BODY
Le Blond Makino
PL1011-5 10" 1-3/4" 11" Vellumoid Plated None PVC (w/handle)
Le Blond Makino
PL1011-5-1 10-1/4" 1-3/4" 11" Vellumoid Plated Plated PVC (w/handle)
Le Blond Makino
PL1012-5 10-1/4" 1-3/4" 11-5/8" Buna N Plated None PVC (w/handle)
Elox CNC
PL1014 10-1/4" 1-1/4" 13-1/2" Cork Plated None PVC Mitsubishi Hitachi
Mitsubishi
PL1014-3 10-1/4" 1-1/4" 13-1/2" Cork Plated None PVC 3 micron
PL1014-5 10-1/4" 1-1/4" 13-1/2" Cork Plated None PVC Mitsubishi (w/handle)
Mitsubishi Diafilpa PL1011-5
PL1014-5-1 10-1/4" 1-1/4" 13-1/2" Cork Plated Plated PVC (w/handle)
2
COOLING TOWERS, BOILERS, PLATING,
CONDENSERS, RUST INHIBITORS,
WASTE TREATMENT, WATER TREATMENT,
BIOCIDES AND PH / ORP ADJUSTMENTS
Wide model selection
Capacities to 25 GPH
Choice of control options
Standard and optional liquid ends to meet any
application
Encapsulated electronics
Pump electronics are enclosed in housing of corro-
sion-resistant polypropylene, protecting the pump
SERIES 'AA' from spilled chemical and corrosive atmosphere.
0 - 48 GPD Pump status LED
Provides visual indicator of pump operation
Capable of handling
Acids Soaps Wetting Agents
Caustics Brighteners Inhibitors
Flocculents Detergents Filter Aids
Chlorine Dyes ...and many more
Inherent pressure relief
Should the back pressure exceed the strength of
the magnetic force developed by the power coil, the
pump will stop stroking, preventing any damage and
eliminating the need for a pressure relief valve.
Saves you money
Power used only during discharge portion of each
stroke. Minimum electrical consumption and low
heat.
Low maintenance
One moving unit, the armature-diaphragm assembly.
No lubrication required. Modular construction pro-
vides easy replacement of components and major
SERIES 'B' & 'C' assemblies.
0 - 600 GPD Free installation kit included
Contains essential components for installation:
Polyethylene suction & discharge tubing
Foot valve & strainer
Injection check valve
UL listed CE compliant
32
CONTROL OPTIONS
2
INTERNAL CONTROL, Series AA1, B1, C1 ampere-hours. These pumps respond to any external
switch closure, providing automatic stroke frequency
These pumps offer the versatility of independently
control or proportional feeding. Series B7 & C7 also
adjustable stroke length and stroke frequency, al- include adjustable electronic pressure control as a
lowing dual manual control of pump output. standard feature. This reduces the electrical load
SERIES 'AA' .006 to 2.0 GPH (.38 to 126 ml/M) to the solenoid based on pump pressure required.
Series AA_4, AA_5 and AA_6 provide output MICROPROCESSOR CONTROL, Series AA9,
ranges of 100:1. B9, C9
Series AA_7 and AA_8 offer output ranges of These are programmable electronic pumps featur-
66:1. ing microprocessor-based control which employs
SERIES 'B' & 'C' .008 to 25 GPH an LCD display and a 4-key tactile keypad. They
(.05 to 1578 ml/M) also come with continuous memory back-up which
Series B and C provide output ranges of 100:1. insures the integrity of your programmed values in
the event of a power failure and keypad adjustable
INTERNAL / EXTERNAL CONTROL, pressure control which reduces noise, shock and
Series AA7, B7, C7 vibration during operation. The pump can be run
These metering pumps offer the versatility of a in either manual / external mode select (0-100 sph
selector switch for either internal (manual) or ex- or 1-100 spm) or external modes of 4-20 mA input
ternal (automatic) control. Perfect for proportional control, both direct or inverse. It can also multiply
treatment installations, or for use with the A/D con- or divide incoming pulses from a voltage free reed
verter or ampere-time meters where pump stroke switch, transistor, opto-coupler or Hall Effect sensor.
frequency must vary linearly in response to plating
SERIES 'AA'
2
SERIES 'B'
MODEL & PRICE CODE NO. TUBING OUTPUT OUTPUT MAXIMUM
SIZE GPH ml/min. PRESSURE
INTERNAL INTERNAL/EXTERNAL MICROPROCESSOR
CONTROL CONTROL CONTROL Inches MIN. MAX. MIN. MAX. PSI (Bar)
B111-95T B711-95T B911-95T 3/8 .008 1.6 .50 100 150 (10.3)
B121-95T B721-95T B921-95T 3/8 .012 2.5 .79 158 100 (6.9)
B131-75T B731-75T B931-75T 1/2 .022 4.5 1.42 284 50 (3.4)
B141-15 B741-15 B941-15 1/2 .035 7.0 2.21 442 30 (2.1)
SERIES 'C'
MODEL & PRICE CODE NO. TUBING .OUTPUT OUTPUT MAXIMUM
SIZE GPH ml/min. PRESSURE
INTERNAL INTERNAL/EXTERNAL MICROPROCESSOR
CONTROL CONTROL CONTROL Inches MIN. MAX. MIN. MAX. PSI (Bar)
C111-75T C711-75T C911-75T 1/2 .012 2.5 .79 158 150 (10.3)
C121-75T C721-75T C921-75T 1/2 .02 4.0 1.26 252 100 (6.9)
C131-25T C731-25T C931-25T 1/2 .045 9.0 2.84 568 60 (4.1)
C141-35T C741-35T C941-35T 1/2 .10 20.0 6.3 1262 25 (1.7)
C771-25T 1/2 .05 10.0 3.16 631 80 (5.5)
C781-35T - 1/2 .125 25.0 7.9 1578 30 (2.1)
ACCESSORIES
WALL MOUNTING BRACKET ASSEMBLY SPLASH GUARDS
A wall mounted pump is up and away from the Splash guards have a see through cover that protects
chemical drum, minimizing the chance for mishap. against chemical sprays or splashes and accidental
Rugged, polyurethane coated steel bracket provides movement of the switch and adjustment knobs.
stable mounting surface. All hardware is
included for mounting to stud, concrete PRICE
DESCRIPTION
PRICE
or hollow block walls. CODE NO. CODE NO.
34643 Series B & C 10583
34
NOTE: Models C_4 are not compatible with four-function valves. PRICE
DESCRIPTION
CODE NO.
2
SAFELY AND RELIABLY
Wide selection of materials:
SS - 316 stainless steel PP - Polypropylene
AL - Aluminum K - PVDF
NSS - Conductive nylon N - Nylon
" - 2" sizes
flows to 150 U.S. GPM (568 l/m)
Patented lube-free air system
Will not stall at slow speeds
Self-priming
Runs dry
Here is a line of remarkably rugged and durable longer operating life and easier maintenance at a
self-priming, double diaphragm pumps. Lube-free lower cost.
and non-stalling, all models will handle any product Since these pumps are driven by compressed air,
that pours, from clear water to highly viscous, abra- there is no need for shielded electrical connections
sive and chemically aggressive materials. Proven or explosion-proof motors. All models can run dry
to handle suspended solids and abrasives without because there are no close fitting or sliding parts
damage to the product or the pump. in the fluid section. Flow rates can be controlled
The unique pump design utilizes far fewer parts to produce from zero to maximum flow simply by
than other pumps on the market. This results in increasing or decreasing air flow or pressure.
PLASTIC MODELS:
1/4" BOLTED PPBN- PPBTF- PPBL-1/4 NSSBTF-
NBTF- /
1 4
KBTF- KBL-
SPECIFICATIONS 11.4
Capacity:
Adjustable . . . . . . . . 0 to 4.3 GPM (16.3 liters/min.)
Maximum temperature:
PVDF model . . . . . . . . . . . . . . . . . . . . . 200F (93C)
Other models . . . . . . . . . . . . . . . . . . . . . . 150F (66C)
Maximum air pressure:
All models . . . . . . . . . . . . . . . . . . . 100 PSI (6.8 bars)
Dry lift capacity @ 100 PSI (6.8 bars): 15 ft. (4.5
meters)
Maximum solids: . . . . . . . . . . . . . . . . . . . 1/16" (1.6 mm)
Air supply:
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Fluid inlet / discharge: . . . . . . . . . . . . . . . . . 1/4" NPT
36
1/2" BOLTED
PLASTIC MODELS: PPBN-, PPBTF-, PPBL-,
PPBV-, NBTF-, KBTF-, KBL-, KBV-, NSSBTF-
METALLIC MODELS: ALBN-, ALBTF-, ALBL-,
SSBTF-, SSBL-, SSBN-
DISCHARGE FLOW-Liters/Min.
SPECIFICATIONS 7,6 15,1 22,7 30,3 37,9 45,4 53,0 60,6 68,1
0 2 4 6 8 10 12 14 16 18
DISCHARGE FLOW-U.S. Gals./Min.
Stock models have a side port. Optional center, top or dual ports
must be specied when ordering. Fluid is not separated within the
single piece manifold when dual ports are specied.
DISCHARGE FLOW-Liters/Min.
SPECIFICATIONS 7,6 15,2 22,8 30,4 38,0 45,6 53,2 60,8
100 230
PRESSURE INLET/OUTLET PSIG (BAR)
0 2 4 6 8 10 12 14 16
DISCHARGE FLOW-U.S. Gals./Min (GPM)
37
2
1" BOLTED
(8,2) 10
SPECIFICATIONS
TOTAL HEAD IN FEET (METERS)
SPECIFICATIONS
SPECIFICATIONS
Capacity: Maximum solids: ..................1/4" (6.4 mm)
Adjustable 0 to 95 GPM (360 liters/min.) Air supply:
Maximum temperature: Inlet........................................3/4" FNPT
PVDF, AL & SS models.......200F (93C) Outlet.....................................3/4" FNPT
Other models......................150F (66C) (Air flow control valve on plastic pumps,
Minimum air pressure:....20 PSI (1.2 bars) 3/4" FNPT)
Maximum air pressure: Fluid inlet / discharge:
PVDF model.................70 PSI (4.8 bars) Plastic pumps .......................1" flange
Other models..............100 PSI (6.8 bars) Metal pump..............1" flange (38 mm)
Dry lift capacity @ 100 PSI (6.8 bars):
.....................................10 ft. (3 meters) (ANSI & DIN compatible)
SPECIFICATIONS
Capacity: Maximum solids:
Adjustable..0 to 150 GPM (569 liters/min.) ...........................................1/4" (6.4 mm)
Maximum temperature: Air supply:
PVDF, AL & SS models........200F (93C) Inlet ........................................ 3/4" FNPT
Other models.......................150F (66C) Outlet ......................................3/4" FNPT
Minimum air pressure for AL & SS pumps: (Air flow control valve on plastic pumps,
..................................... 30 PSI (2.0 bars) 3/4" FNPT)
Maximum air pressure: Fluid inlet / discharge:
PVDF model................. 70 PSI (4.8 bars) Plastic pumps............................ 2" flange
Other models.............. 100 PSI (6.8 bars) Metal pumps................ 2" flange (51 mm)
Dry lift capacity @ 100 PSI (6.8 bars): (ANSI & DIN compatible)
......................................10 ft. (3 meters)
39
2
BOLTED MODELS
MATERIAL OF CONSTRUCTION PRICE CODE NUMBER
MODEL DIAPHRAGM
1
/4" 1
/ 2" 1"
NUMBER * WETTED
HOUSINGS** ELASTOMERS/ 0-4 GPM 0-14 GPM 0-40 GPM
VALVE SEATS** (16 l/m) (53 l/m) (152 l/m)
PPBN-_____
* Polypropylene Geolast / Nitrile 55-7244B 55-7287 55-7602
PPBTF-____
* Polypropylene PTFE 55-7245 55-7288 55-7603
PPBL-_____
* Polypropylene Santoprene / EPDM 55-7270 55-7289 55-7604
PPBV-_____
* Polypropylene Viton 55-7290 55-7605
NBTF-_____
* Nylon PTFE 55-7246 55-7291
NSSBTF-___
* Conductive Nylon PTFE 55-7271 55-7292
KBTF-_____
* PVDF PTFE 55-7247 55-7293 55-7606
KBL-_____ PVDF Santoprene / EPDM 55-7286 55-7294 55-7607
*
KBV-_____ PVDF Viton 55-7295 55-7608
*
ALBN-_____
* Aluminum Geolast / Nitrile 55-7296 55-7609
ALBTF-____
* Aluminum PTFE / nylon 55-7297 55-7610
ALBL-_____
* Aluminum Santoprene / EPDM / PP 55-7298 55-7611
SSBTF-____
* Stainless steel PTFE 55-7600 55-7612
SSBL-_____
* Stainless steel Santoprene / EPDM 55-7601 55-7613
SSBN-_____
* Stainless steel Geolast / Nitrile 55-7299 55-7614
1. Geolast is a nitrile blend and is a replacement for 1. All pumps are lube-free and non-stalling. A
Buna-N or Neoprene. Use chemical resistance in- clean, dry compressed air supply is all that is
formation for Buna-N. needed.
2. Santoprene is an EPDM blend and is highly resistant 2. BSP thread models available.
to some acids and basses. Use the chemical resis- Consult Sales Department.
tance information for EPDM. 3. Flanges, available on 11/2" and 2" sizes only, are
3. Aluminum pumps have polypropylene valve seats, ex- slotted for DIN or ANSI compatibility.
cept aluminum w/ TFE models which have nylon valve
seats.
4. All pumps built with TFE contain a backup diaphragm
of Santoprene.
5. NSSTF pumps are constructed of 316SS lled nylon
and include ground / bond lugs.
6. Air system constructed of polypropylene, except ny-
lon and aluminum w/TFE models which have nylon air
systems.
SHIPPING WEIGHTS
OPTIONAL EQUIPMENT
ACCESSORY KIT for drum transfer applications PUMP PRICE CODE NUMBER
Turns diaphragm pump into an ideal drum pump. SIZE PP PVDF AL
Includes: polypropylene or PVDF suction tube 1/2" 44-7236 44-7239 44-7628
with 2" NPT polypropylene barrel adapter. 1" 44-7237 44-7240
DESIGNED TO ELIMINATE
2
PRESSURE SURGES AND PULSATIONS
Non metallic solution contact
Polypropylene to 125 psig @ 175F
PVDF to 125 psig @ 225F
Nylon to 125 psig @ 175F
Manual or automatic adjusting models.
For pump sizes - 1/2", 1" or 2"
Improve accuracy and life of pumps and meters.
Stainless steel clamp band design for easy
maintenance.
One-way air inlet valve prevents product backflow
if bladder is ruptured.
Eliminates costly pipe system vibration and
leakage.
1" MANUAL MODEL
TYPICAL INSTALLATION
SUCTION SIDE -
Dampener acts as an accumulator to provide a close source of product
when pump inlet check balls are opened. Helps prevent cavitation. Acts
as a dampener when high inlet pressures are generated as pump's inlet
check valves are closed. Minimizing stress and shock on pipes, fittings,
Pulsation dampeners are uniquely designed to eliminate manifolds and extends diaphragm life.
97% of all types of fluid flow pressure spikes. The unwanted
result of these pressure spikes is hydraulic shock, material
foaming or material splashing.
Air
Air Dampener
Dampener
Pulsation dampeners reliably protect diaphragm pumps,
hose
hose
pipes, fittings and equipment from vibration and fatigue. Pumps Fluid
Fluiddischarge
discharge
and filter chambers last longer and are more reliable when they
are not exposed to harmful fluid shock waves. Installation is Tee
easy. Connect to fluid line via tee and supply compressed air Tee
or nitrogen to charge the dampener. A.O.D.
A.O.D.
Dampener
Dampener PUMP
PUMP
The highly efficient dampening provided by these devices Pump
Pump
makes them ideal for use as a suction stabilizer on all types of inlet
inlet
pumps or after valves to also protect downstream equipment.
Pulsation dampeners come in two models Manual Tee
adjustment for continuous dampening requirements and Tee
Automatic adjusting for variable pump discharge pressures.
DISCHARGE SIDE -
Models are available in three sizes. Dampener acts as a shock absorber to minimize pulsations and
water hammer. Should be mounted as close to pump discharge as
possible to absorb shock at its source. Will prevent leaking joints
and fittings due to pulsation. Allows meters to be used without
damage and extends the life and reliability of pump components.
TO ORDER
2
Select Kompressed-Air-Konditioner based on flow ings for both components are shown. System maximum
rate or pipe size. Assembly includes dryer element and pressure is limited by the lowest pressure rating of
filter pads. Select choice of drain style. Pressure rat- filter / dryer and drain.
KOMPRESSED-AIR-KONDITIONERS
WITH ELEMENT
SCFM @ MAX. DIFF. CONNS. SIONS SHIPPING
MODEL 100 PSI PSI @ 150 PSI NPT WEIGHT Dehydrated
Clay
Molecular Dehydrated
Sieve Clay / Carbon
* PRESS. MAX. SCFM DIMEN- LBS.
DIA. HT. PRICE CODE NO.
SF-B25- 7 250 3.5 PSI " 2" 7" 3 79-0070 79-0094 79-0301
SF-A38- 30 250 4.0 PSI " 3" 11" 8 79-0002A 79-0004 79-0302
SF-C418-1 70 250 3.5 PSI 1" 4" 20" 18 79-0034A 79-0036 79-0303
SF-E625-1 150 200 3.5 PSI 1" 6" 21" 29 79-0050 79-0056
SF-D832-2 300 150 11.0 PSI 2" 8" 34" 25 79-0072 79-0093
* Maximum flow - intermittent operation
REPLACEMENT ELEMENTS
PRICE DESCRIPTION CODE NO.
FOR MODEL DESCRIPTION CODE NO. PRICE
MOLECULAR SIEVE media is recom-
SF-B25- DEHYDRATED CLAY media hydro- 79-0071A mended for those applications requiring 79-0021A
SF-A38- philically removes water and oil vapors 79-0003A exceptionally pure air at low dewpoints 79-0022A
and medium size particles from the air free of oil vapor. Pressure dewpoint
SF-C418-1 stream. Pressure dewpoint is lowered 79-0035A is lowered approximately 80F below 79-0023A
SF-E625-1 approximately 25F below the entering 79-0051A the entering air temperature. For use 79-0024A
SF-D832-2 air temperature. 79-0073A with oilless compressors or a coalescer 79-0025A
upstream.
AIR COALESCERS
2
A
Remove aerosols economically 99.98% efficiency, to 0.3 micron
C
The use of SERFILCO Air Coalescers is rec- have plastic bowls with metal guards. The letter D
ommended to stop the negative effects of water, oil in the model signifies an internal automatic drain
and solids concentrations on instruments, air tools, which is standard on 1/2" and larger models. The
valves and desiccant dryers. The result is longer 1/4" model has a manual drain. B
lasting equipment, fewer production stoppages and Plastic bowls are rated 150 psig at 125F. Metal
higher quality products. bowls are rated 200 psig at 175F.
Models starting with B have metal bowls. Others
SERFILCO 5 Micron Air Filters are designed bowls. Others have plastic bowls with metal
to be used independently for less sensitive filtra- guards. All models come standard with an internal
tion applications and as prefilters for the high ef- automatic drain. B
ficiency air coalescer designs, thereby extending Plastic bowls are rated 150 psig at 125F.
the operating life of the high efficiency coalescing Metal bowls are rated 200 psig at 175F.
element.
These air filters cover a wide variety of sizes
and flow rates. Models starting with B have metal
KOMPRESSED-AIR-KONDITIONERS K-101L
2
remove water and oil vapor to prevent condensation purification is required.
downstream. Three choices of desiccant elements
are available: MOLECULAR SIEVE ELEMENT
Highly porous alumina-silicate complexes produce
DEHYDRATED CLAY ELEMENT exceptionally low dew points - as much as an 80F
Effective for both water and oil removal. Requires initial pressure dew point depression. Molecular
no coalescing or air preparation. A general pur- sieve material will be coated with oil passing through
pose desiccant which produces initial dew point the system thereby reducing efficiency and life
de-pressions (pressure dew points) of 20 to 25F. expectancy. They are generally used with oil-less
Life expectancy is up to three months depending on compressors or a coalescing filter is used to
humidity, flow rate and frequency of operation. remove the oil before the air enters the Filter/Dryer.
The addition of a general purpose filter will extend
DEHYDRATED CLAY WITH ACTIVATED the life of the coalescing filter element, further
CARBON ELEMENT reducing cost. Always install filters before the
A layer of activated carbon following the clay Molecular Sieve models.
desiccant produces slightly lower initial dew points.
It provides better removal of noxious gasses and oil
TYPICAL INSTALLATIONS
INSTALLATION RECOMMENDATION
It is intended that all models be located as
far from the compressor as practical. Reason-
able attention to the filter location and element
replacement will result in the finest air drying To operating equipment
and filtration possible.
(clay desiccant)
Drying
Air Compressor
Pre-filtration
Air to Air Coalescing, (molecular sieve)
After Cooler Drying
(Use when K-A-K
entering air 2
temperature is
above 90F)
Filter Coalescer
46
DRUM PUMPS
Laboratory
SERIES DP 47
3
Made in the U.S.A.
PUMP TUBES
Pump available in polypropylene,
PPP high temperature polypro,
CPVC, pure PVDF or 316 stainless steel.
Lengths of 27, 39, 47, 60 and 72.
Seal-less, one-piece outer tube with screw-on
foot.
No weak spin welds or glued components.
Easy on-site service. No special tools required.
MOTORS
Heavy duty 1.1 HP electric motors
(open or TEFC) with variable speed control for
precise delivery without splashback.
Economy 450 watt motor.
PUMP TUBES
Explosion-proof and air driven motors
SERIES DP Drum Pumps combine modern manu- ably with any of our electric or air motors. They can be
facturing techniques with proven and reliable design quickly changed to meet particular pumping or motor
features. They are a convenient and efcient means requirements.
of transferring and dispensing most liquid chemicals Simply insert the pump into the liquid for immediate
from drums, carboys and tanks. pumping. No priming is necessary since the rotor is
These pumps are available in a selection of engi- located at the bottom end of the pump. Flow may be
neered plastics or polished 316 stainless steel thus controlled with the unique speed control knob on the
providing a great range of chemical compatibility. ODP-S and ENC-S motors to prevent splashing and
The pumps are available in lengths to meet your re- control the volume. Keep these handy pumps on lo-
quirements and all pumps can be used interchange- cation throughout your plant for convenient solution
transfer.
Pump tubes are designed with threaded joints for easy We utilize a seal grade carbon for our lower bushing (pure
maintenance and individual component replacement with- carbon 6038C), the most chemically resistant carbon avail-
out special tools. Our guide sleeves are PTFE, with a spe- able. Our shafts are Hastelloy C-276 (PP, PPP, CK and KY
cially extruded n which secures it inside the inner tube. models), or 316 stainless steel (SS models).
3
Handwheel
modular
design
Optional 1 or 3/4
1086
barbed 42 3/4"
Thick, robust fitting
wall construction TFE guide sleeve
1003
39 1/2"
finned design
Carbon insert
Impeller/rotor interchange-
able for high volume/high
pressure models 1 5/8"
SAFETY PRECAUTIONS
Verify the chemical compatibility of the material of your pump A ground wire should be used on any explosion-proof motor as
with the liquid you are pumping. Never use a pump that is not well as the container when transferring explosive material. This
chemically compatible with the uids you are pumping or seri- warning pertains to electric and pneumatic motors.
ous bodily harm, re or explosion could result.
Only metallic pumps should be used for transferring am-
The high velocity ow of liquid through a pump could create
mable or explosive liquids. Do not pump an explosive or
static electricity. All pumps and containers must be properly
ammable liquid with ODP, ENC, Air (B) or Air (F) motors.
grounded and bonded to prevent static discharge and sparking,
which could cause electric shock, re or explosion. Follow all safety recommendations regarding clothing and gog-
gles, which should be worn when using these pumps.
49
3
PP8327-1 52-1008 27 (690 mm)
tions and solutions which corrode or oxidize metals, such PP8339-1 52-1000
Polypropylene
39(1000 mm)
as hydrouoric or sulfuric acid. w/Hastelloy 1-5/8
PP8347-1 52-1001 47(1200 mm) 1
C276, PTFE, (41mm)
Maximum liquid temperature 130oF (54oC). PP8360-1 52-1003 60(1525 mm)
carbon
Not for use with ammable liquids. PP8372-1 52-1005 72(1825 mm)
Optional thermal
overload or
low voltage Motor housing provides
release switches added chemical resistance
3
time. Includes 16 ft. cord w/molded plug. For viscosities to 1500 cps or specic gravity up to 1.8.
15
4 Not suitable for hazardous duty. Weight: 12 lbs. (6 kg.)
0 0
0 11 22 33 44 55 GPM MODEL NO. PRICE CODE NO. MOTOR VOLTAGE
16 For viscosities up to 750 cps or specic gravity up to 1.8. Includes grounding cable.
45
12 Weight: 20 lbs. (9.5 kg.)
30
8 MODEL NO. PRICE CODE NO. MOTOR VOLTAGE
15
4 EXC-UL-115 55-0744 115V/1/50-60
0 0 EN5-240* 55-7167 220-240V/1/50
0 10 20 30 40 50 GPM
* Protection class (PTB): EEx de 11C T6
0 45 90 135 180 LPM
** 620 watt input / 430 watt output
For ammable or explosive liquids.
TDH
m ft.
AIR (F) AIR (F) AIR DRIVEN MOTOR AIR (F)
12 .73 HP (550 watts), 28 cu. ft./min. @ 90 PSI, 10,000 RPM. Aluminum motor housing is plas-
High head
9 30 tisol coated to prevent sparking. Includes mufer, lter, and trigger valve for ow control. For
viscosities to 750 cps or specic gravity to 1.75. Air line lter, PSI regulator and automatic oiler
6 20
recommended. Weight: 3.5 lbs. (1.6 kg.)
3 10
MODEL NO. PRICE CODE NO.
0 0
0 10 20 30 40 GPM AIR (F) 52-0100
TDH
AIR (B) AIR (B) AIR DRIVEN MOTOR AIR (B)
m ft.
12 .5 HP (370), 22 cu. ft./min. @ 90 PSI, 10,000 RPM. Aluminum motor housing, glass reinforced
30 High head plastic pump mounting bracket. Not suitable for hazardous duty. For viscosities to 450 cps or
9 specic gravity up to 1.6. Mufer included. When air supply line is tted with an optional regula-
6 20 tor, the pump output can be precisely controlled. Weight: 3 lbs. (1.4 kg.)
3 10 MODEL NO. PRICE CODE NO.
0 0 AIR (B) 55-0701
0 10 20 30 40 GPM
Not for use with ammable liquids.***
0 50 100 150 LPM
CAUTION: Air motors are not recognized under any current Underwriters Laboratory listing
*** program. Consult a qualied safety engineer for suitability for use in a hazardous area or with
ammables.
52
Chemicals
Motor type: ODP-S
Pump assembly: CPVC PRICE CODE NO. VOLTAGE
Pump length: 39(1000 mm) 52-9430 115V
3
PVC hose: 6 ft. (1.8 m), I.D. 1 (25 mm) 52-9431 240V
Dispensing nozzle: 1 (25 mm), polypropylene
Barrel adapter: Polypropylene
Storage bracket: 16 gauge coated steel
Max. viscosity: 1500 CPS / Mpas
Max. temperature: 190oF(900C)
PACKAGE 2 Engineered to transfer mildly corrosive liquids. Common applications include: Hydrochloric
Acids & Alkalies Acid, Nitric Acid - 20%, Acetic Acid and Sulfuric Acid
Motor type: ODP-S
Pump assembly: Polypropylene
PRICE CODE NO. VOLTAGE
Pump length: 39(1000 mm)
PVC hose: 6 ft. (1.8 m), I.D. 1 (25 mm) 52-9400 115V
Dispensing nozzle: 1 (25 mm), polypropylene 52-9401 240V
Barrel adapter: Polypropylene
Storage bracket: 16 gauge coated steel
Max. viscosity: 1500 CPS / Mpas
Max. temperature: 130oF(550C)
PACKAGE 3 Engineered for transferring very concentrated and extremely aggressive liquids. Common
applications include: Sulfuric Acid 66 Baume, Propionic Acid, Concentrated Nitric - 98%
Concentrated
and Hydrouoric Acid.
Acid & Alkalies
Motor type: ENC-S
Pump assembly: PVDF PRICE CODE NO. VOLTAGE
Pump length: 39(1000 mm)
PVC hose: 6 ft. (1.8 m), I.D. 1 (25 mm) 52-9420 115V
Dispensing nozzle: 1 (25 mm), PVDF 52-9421 240V
Barrel adapter: Polypropylene
Storage bracket: 16 gauge coated steel
Max. viscosity: 1500 CPS / Mpas
Max. temperature: 175oF(800C)
Unique design allows users to safely measure and transfer mildly corrosive liquids. Com- PACKAGE 4
mon applications include: Hydrochloric Acid, Nitric Acid - 20%, Acetic Acid and Sulfuric
MEASUREMENT
Acid.
Acid & Alkalies
Motor type: ODP-S
Pump assembly: Polypropylene PRICE CODE NO. VOLTAGE
Pump length: 39(1000 mm)
PVC hose: 6 ft. (1.8 m), I.D. 1 (25 mm) 52-9500 115V
Dispensing nozzle: 1 (25 mm), polypropylene 52-9501 240V
Flow meter: Digital / polypropylene totalizer
Barrel adapter: Polypropylene
Storage bracket: 16 gauge coated steel
Max. viscosity: 300 CPS / Mpas
Max. temperature: 130oF(550C)
Unique design allows operators to safely measure and transfer concentrated and very PACKAGE 5
aggressive liquids. Common applications include: Sulfuric Acid 66 Baume, Propionic
MEASUREMENT
Acid, Concentrated Nitric - 98 and Hydrouoric Acid.
Concentrated
Motor type: ENC-S
PRICE CODE NO. VOLTAGE Acid & Alkalies
Pump assembly: PVDF (Kynar)
Pump length: 39(1000 mm) 52-9510 115V
PVC hose: 6 ft. (1.8 m), I.D. 1 (25 mm) 52-9511 240V
Dispensing nozzle: 1 (25 mm), PVDF
Flow meter: Digital / PVDF totalizer
Barrel adapter: Polypropylene
Storage bracket: 16 gauge coated steel
Max. viscosity: 300 CPS / Mpas
Max. temperature: 175oF(800C)
53
3
Versatile, lightweight pump for the transfer of acids or alkalies 12
from glass carboys and similar containers. Pump will handle liq-
8
uids to 250 cps. Motor is 160 watt with built-in overload and
manual reset for safety. Includes 16 cord with molded plug, 10 4
of 1/2 vinyl hose, polypropylene ow nozzle & wall bracket.
0
0 2 4 6 8 10 12 14 GPM
ACCESSORIES
PRICE
STRAINER
CODE NO.
Recommended when pumping dirty liquids PP for PP or PVDF pumps...... 55-0282A
or where abrasive particles are present. SS for SS pumps..................... 55-0283A
NOZZLE
PRICE
Provides controlled dispensing of liquid without splashing for safe CODE NO.
chemical transfer. Polypropylene, Viton and Hastelloy
Ideal for dispensing into small containers, the nozzle features full (shaft and spring).......................................... 52-0017
one inch ow-through for maximum ow and allows hand held
squeeze control for corrosive applications. Stainless steel and Teon........................... 52-0017S
1 hose barb connection.
PVDF............................................................. 52-0017K
3
Dispenses liquids:
safely
accurately preset volume
easily
push to start
shuts off automatically
OPERATION Versatility
Simply enter the desired volume of liquid with di- 1. Displays volume units in gallons, Imperial gal-
rectional arrows. Press ENTER and the SERFILCO lons, liters, milliliters or cubic meters.
2. Displays ow rate in gallons, Imperial gallons,
Smart Pump Batch Control System engages the mo-
liters, milliliters or cubic meters per minute, sec-
tor, dispenses the required volume, then stops the
ond, or hour.
motor to complete the process. Motor speed control is
3. Language can be displayed in English, German,
also included to dispense at the desireed ow rate.
French, Italian or Spanish, as desired.
4. Available in PP or PVDF for complete chemical
ADVANTAGES
compatibility.
Accuracy within 0.5%. Meter employs Teach In 5. Available with standard pump tube lengths for :
calibration or preset K factors for various specic carboys 27 (700 mm), drum 39 (1000 mm),
gravities. No more estimating or using oor scales tanks 47 (1200 mm), IBCs 60 (1500 mm)
to properly measure corrosive chemicals. and large storage vessels 72 (1600 mm).
Safety operator does not come in contact with 6. Batch Controller operates on 120V or 220V
corrosive chemicals. No more drum tilting with fork power.
lifts, measurement with buckets or pails. Control 7. Smart Motors are available in TEFC or ODP for
transfer of highly corrosive liquids from your stor- any corrosive environment. Both 60 Hz and 50
age container to a mixing tank or process line. Hz motors are available.
*SYSTEM INCLUDES 1 EACH: SERFILCO drum pump Smart Motor, pump tube and batch controller with all
necessary connections.
57
3
Menu guided user friendly operating system allows for cus-
tomized setting. Equipped with E Eprom electronics.
Accuracy 0.5%, 0.4% repeatability.
9V Lithium Battery.
Progressive Cavity
Design
DD 800
Industrial
SERFILCO Progressive Cavity pumps are engineered ferring viscous materials such as polymers, paints,
to transfer high viscosity materials from drums, tanks resins, adhesives and petroleum based products.
and IBCs. Utilizing the principle of positive displace- Series 800 Sanitary Pump
ment, these pumps deliver a continuous ow with SERFILCO series 800 Sanitary Pumps are commonly
little product degradation. The series 700 (Industrial) used throughout the sanitary food processing, phar-
and series 800 (Sanitary) pumps can transfer mate- maceutical, biotechnology, and cosmetic industries.
rials ranging in viscosity up to 100,000 cps/ mPas. Applications include the transfer of tomato paste,
All pumps are constructed from robust 316SS with a mayonnaise, pie llings, salad dressing, shampoos,
choice of stator elastomers. and cosmetic lotions. The series 800 pumps are man-
Series 700 Industrial Pump ufactured according to standards with FDA ap-
SERFILCO series 700 Industrial Pumps are commonly proved materials of construction. The pumps utilize a
used throughout the industrial marketplace for trans- threaded design and tri-clamp ttings for quick clean-
ing, inspection and maintenance.
3
disassembly for cleaning and maintenance.
AIR (F)
AIR (F) AIR DRIVEN MOTOR
.73 HP (550 watts), 28 cu. ft./min. @ 90 PSI, 10,000 RPM. Aluminum motor housing is plastisol coated to prevent sparking.
Includes mufer, lter, and trigger valve for ow control. Air line lter, PSI regulator and automatic oiler recommended.
Weight: 3.5 lbs. (1.6 kg.)
MODEL NO. PRICE CODE NO.
AIR (F) 52-0100
WARNING: Pumping of ammables or combustible liquids can generate a static electric discharge, causing re or explosion resulting in injury or death. Read and
understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air sup-
ply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum,
receiving vessel and metallic pump when pumping ammables. Air motors are not recognized under any current Underwriters Laboratory listing program. Consult a
qualied engineer for suitability for use in a hazardous area or on ammables.
61
3
See page 4 for motor selection.
Fittings: Large Type Acme Thread design enables quick
disassembly for cleaning and maintenance.
Industrial
Electric Motor Industrial Electric Motors 230-380-415-460v/3/50-60Hz
PRICE SHIPPING WT.
MODEL HP KW RPM ENCLOSURE
CODE NO. LBS (Kg)
DD-500 52-8010 0.75 ,55 750-900 TEFC (IP55) 40 (18)
3
Sanitary
Electric Motor Sanitary Electric Motors 230-380-415-460v/3/50-60Hz
PRICE ENCLOSURE SHIPPING WT.
MODEL HP KW RPM
CODE NO. (WASHDOWN) LBS (Kg)
DD-502 52-8020 0.75 ,55 750-900 TEFC (IP55) 40 (18)
DD-512 52-8021 1 ,75 750-900 TEFC (IP55) 52 (24)
DD-522 52-8022 1.5 1,1 750-900 TEFC (IP55) 58 (25)
3
60 (3.5) 60 (3.5) A
50 (3) 50 (3)
40 (2) 40 (2)
30 (1.5) 30 (1.5)
20 (1) 20 (1)
10 (.5) 10 (.5)
0 0 0 0
0 1 (4) 2 (8) 3 (11) 4 (15) 5 (19) 6 (23) 0 1 (4) 2(8) 3 (11) 4 (15) 5 (19) 6 (23) 7 (26) 8 (30)
Flow Rate GPM (LPM) Flow Rate GPM (LPM)
VISCOSITY VISCOSITY
CURVE HP KW CURVE HP KW
(cps) (cps)
A 1+ .5 ,37 A 1+ .5 ,37
B 10,000+ 1 ,75 B 10,000+ 1 ,75
C 20,000+ 1 1,2 C 20,000+ 1 1,2
D 30,000+ 1.5 1,2 D 30,000+ 1.5 1,2
90 (6) 90 (6)
Pressure PSI (BAR)
80 (5) 80 (5)
70 (4) 70 (4)
60 (3.5) D C B A 60 (3.5) D C B A
50 (3) 50 (3)
40 (2) 40 (2)
30 (1.5) 30 (1.5)
20 (1) 20 (1)
10 (.5) 10 (.5)
0 0 0 0
0 2 (8) 4(15) 6 (23) 8 (30) 10 (38) 12 (45) 14 (53) 0 2 (8) 4 (15) 6 (23) 8 (30) 10 (38) 12 (45) 14 (53) 16(61) 17(64) 18 (68)
Flow Rate GPM (LPM) Flow Rate GPM (LPM)
VISCOSITY VISCOSITY
CURVE HP KW CURVE HP KW
(cps) (cps)
A 1+ .5 ,37 A 1+ .5 ,37
B 10,000+ 1 ,75 B 10,000+ 1 ,75
C 20,000+ 1 1,2 C 20,000+ 1 1,2
NOTE: Accuracy Dof performance curves may
30,000+ 1.5vary +/-1,2
10% based on specic applications. D 30,000+ 1.5 1,2
64
Price Code
NYLON REINFORCED HOSE-CLEAR
11/2 I.D. - per fo 22-0434
3
Plicord; Chemivic Vitner & Versigard are registered trademarks of The Goodyear Tire & Rubber Company
SERIES 'HP' 65
3
IMPROVE PRODUCT QUALITY.
engineered pump
Optional filter capsule
and discharge spout QUALITY ENGINEERED THERMOPLASTIC
CONSTRUCTION
Designed for the transfer or dispensing of concentrates, resistance charts. The use of this pump eliminates having
additives or other liquids which are purchased in bulk but to pour from one container to another and avoids costly
are used in small quantities. This low cost pump delivers one and hazardous spilling and splashing.
pint per stroke or one quart with the forward and back push/
pull of the handle. The variety of materials of construction See following page for specications
enables the user to select those which are specifically
required for his individual needs according to chemical
and ordering information.
Optional point of use filter Liquid transfer Low cost permits use of
for filtering/transfer of for batch mixing. multiple pumps to avoid
pharmaceutical liquids. cross-contamination.
66
PUMP
PRICE
MODEL MATERIALS OF CONSTRUCTION "O"-RING CODE NO.
GASKET
HPV POLYESTER (glass reinforced) - hous- VITON VITON 59-0001
HPN ing, cover plate, piston, valves VITON CORK-NITRILE 59-0002
HPE and bung adapter EPDM EPDM 59-0003
HRV RYTON (glass reinforced) - housing, VITON VITON 59-0004
HRN cover plate, ECTFE piston, valves and VITON CORK-NITRILE 59-0005
HRE bung adapter EPDM EPDM 59-0006
HHV ECTFE (Halar) - housing, cover plate, VITON VITON 59-0007
HHE piston, valves and bung adapter EPDM EPDM 59-0008
All models have 316 stainless steel piston rod, fasteners and suction screen in contact
with liquid. All pumps include a 2" NPT bung adapter.
PRICE PRICE
MODEL DESCRIPTION MODEL DESCRIPTION
CODE NO. CODE NO.
DISCHARGE HOSES (Add to Model No. and Price Code No.) DISCHARGE SPOUT (Add to Model No. and Price Code No.)
-1 8' EPDM, w/polyester elbow & nozzle -1 -M Polyester -M
-2 8' Nitrile (Buna-N), w/polyester elbow & nozzle -2 -N ECTFE -N
-3 8' PVC black vinyl, w/polyester elbow & nozzle -3
BUTTRESS-BUNG ADAPTER (2" buttress x 2" NPT)
-4 8' Cross linked polyethylene, w/polyester elbow -4 (Add to Model No. & Price Code No.)
& nozzle
-R Polypropylene/polyester assembly for HP pump -R
-5 8' Cross linked polyethylene, w/ECTFE elbow -5
-S Polypropylene/ECTFE assembly for HR pump -S
& nozzle
-T Polypropylene/ECTFE assembly for HH pump -T
-6 8' EPDM, w/ECTFE elbow & nozzle -6
-7 8' Nitrile (Buna-N), w/ECTFE elbow & nozzle -7 FILTER CAPSULE-PAC
-8 8' PVC, w/ECTFE elbow & nozzle -8 Polypropylene filter capsule with
SUCTION TUBE (Add to Model No. and Price Code No.) FPC-1.0 pleated 1.3 ft.2 polypropylene 1.0 Nominal 59-0011
-A 2 pc. 1" polyester , 34" long w/polyester coupling -A FPC-0.2 media, ECTFE pump adapter, 0.2 Nominal 59-0013
& PTFE tape ECTFE discharge spout.
-B 2 pc. 1" PTFE, 34" long w/ECTFE coupling -B FC-1.0 Replacement filter capsule 1.0 Nominal 59-0012
& PTFE tape FC-0.2 0.2 Nominal 59-0014
-C 2 pc. 1" UHMW polyethylene#, 34" long w/ECTFE -C
coupling WALL BRACKET 55-7149
-E 1 pc. 3/4" PVC flexible, 35" long (prevents tearing -E TYPICAL MODEL: HPN-2AM & PRICE CODE NO.: 59-0002-2AM
of drum liners) Registered trademarks: Teflon, Viton- DuPont Dow Elastomers;
#
Ultra High Molecular Weight polyethylene Ryton- Phillips Chemical; Halar - Ausimont
SAFETY PRECAUTIONS
Plastic pumps are not designed nor intended to be used for transferring ammable or explosive liquids.
Only metallic pumps which can be grounded and bonded should be used for this purpose.
Refer to a chemical resistance data chart for compatibility of materials with liquids to be pumped. Always
wear protective safety clothing such as gloves, apron and goggles.
67
MODEL PRICE
PH10 4A B
CODE NO.
3
All polyethylene construction. Hand operated bellows. Fits
5-gal. cans, bottles or drums. Ideal for mildly corrosive fluids at
ambient temperatures. Top vent cap is syphon breaker. 16" long
tube, 21" long hose.
PROTECTIVE APPAREL
METAL PISTON PUMPS
MUST BE WORN. Fits 15, 30 and 55 gal. containers. Includes 2" IPS threaded
male adapter. Pumps 8 oz. on each upstroke.
316 stainless steel and PTFE for alkalies, mild acids.
OPTIONAL
GROUNDING AND BONDING CABLES PRICE
For use with metal pumps and containers to prevent static discharge. BONDING CABLE CODE NUMBER
When pumping flammable or combustible liquids from one container 10 ft. long, spring clamp at each end.
55-0245
to another, both containers must be effectively bonded and grounded to
prevent discharge of sparks of static electricity which could cause explosion GROUNDING CABLE
and bodily harm. 6 ft. long, spring clamp one end, spade lug one end. 55-0246
DRUM PUMP 68
The information contained in this Drum Pump Chemical Resistance Guide is to be used only as a general guide for proper drum
pump tube selection. No warranty is implied nor is any guarantee provided. When compatibility data are inconclusive, field test-
ing is recommended. An asterisk indicates the material is flammable and may only be handled with a stainless steel pump tube
and appropriate drive motor which are properly grounded and bonded according to Operating Instructions. Always consult with
a safety engineer for proper drive motor selection when pumping flammables. All test data listed is at room temperature (72F,
22C) unless otherwise stated.
3
R = Recommended Use only explosion-proof motors on flammable liquids. Only metallic pumps should be used
M = Minor to moderate, should for transferring flammable or explosive liquids.
be field tested All pumps and containers must be properly grounded and bonded to prevent static discharge
X = Not recommended and sparking, which could cause electric shock, fire or explosion. A ground wire should be
= No data used on any explosion-proof motor as well as the container when transferring explosive material.
* = Flammable or explosive Always consult with a Safety Engineer for proper pump / motor selection.
CP
ST
CP
ST
VC
PO
PV
PO
PV
AI
AI
VC
NL
NL
/P
DF
LY
DF
LY
/P
ES
VD
P
ES
P
(K
(K
RO
RO
VD
SS
SS
F-
YN
YN
PY
F-
PY
MA
TE
AR
TE
AR
LE
LE
MA
EL
EL
X1
NE
)-
NE
X1
31
31
75
MA
MA
-M
-M
75
6-
6-
F
X.
X.
AX
AX
MA
(80
MA
17
17
(80
.1
.1
X1
C
5
X1
30
30
F(
F(
)
75
75
F
F
80
80
F
F
(54
(54
C
C
(80
(80
)
C
C
C
)
)
)
)
R = Recommended Use only explosion-proof motors on flammable liquids. Only metallic pumps should be used
M = Minor to moderate, should for transferring flammable or explosive liquids.
be field tested All pumps and containers must be properly grounded and bonded to prevent static discharge
X = Not recommended and sparking, which could cause electric shock, fire or explosion. A ground wire should be
= No data used on any explosion-proof motor as well as the container when transferring explosive material.
* = Flammable or explosive Always consult with a Safety Engineer for proper pump / motor selection.
3
ST
ST
CP
CP
PO
PV
PO
PV
AI
AI
VC
VC
NL
NL
DF
LY
DF
LY
/P
/P
ES
ES
P
P
(K
(K
RO
RO
VD
VD
SS
SS
YN
YN
PY
F-
F-
PY
TE
TE
AR
AR
LE
LE
MA
MA
EL
EL
)-
NE
)-
NE
X1
X1
31
31
MA
MA
-M
-M
75
75
6-
6-
X.
X.
F
F
AX
AX
MA
MA
17
17
(80
(80
.1
.1
X1
X1
5
30
30
C
C
F(
F(
75
75
F
F
)
)
80
80
F
(54
(54
C
C
(80
(80
C
)
C
C
)
)
)
Bromic acid R R R Cresylic acid (PVDF, R to 150F/66C) R R M
Bromine liquid (PVDF, R to 150F/66C) R X X * Cyclohexane X X R X
Bromine water R M X * Cyclohexanol X X M X
* Butane X X R X * Cyclohexanone X X M X
* Butyl acetate
________________________________________________ X X M X Diacetone alcohol X X R X
________________________________________________
Butyl phenol * Dichloroethylene X X X X
* Butylene X X R X Diesel fuels X R R X
Butyric acid R R R X * Diethyl ether X X M X
Calcium bisulfide R R M R * Diisobutylene X X M X
Calcium bisulfite
________________________________________________ R R M R Dimethyl formamide X R X
________________________________________________
Calcium chlorate R R R R Dioctyl phthalate R
Calcium chloride R R M R Dyes R
Calcium hydroxide R R R R * Epichlorohydrine X X R X
Calcium hypochlorite R R R R * Ethanolamine X X R X
________________________________________________
(PVDF & CPVC / PVDF, R to 70F/21C) * Ether
________________________________________________ X X R X
Calcium nitrate R R M R * Ethyl acetate X X R X
Calcium sulfate R R R R * Ethyl chloride X X R X
Calcium sulfite R M * Ethyl ether X X R X
* Carbon disulfide X X R X * Ethylene chloride X X R X
________________________________________________
Carbonic acid R R R R * Ethylene dichloride
________________________________________________ X X R X
Carbon tetrachloride X R R X Ethylene glycol R R R R
Cellosolve R R M X * Ethylene oxide X X X
* Cetyl alcohol X X R X Fatty acids M M R M
Chlorine liquid X R X X Ferric chloride R R M R
________________________________________________
Chloroacetic acid X X X X Ferric nitrate
________________________________________________ R R R R
* Chlorobenzene X X R X Ferric sulfate R R R R
Chlorobenzyl chloride (PVDF, R to 125F/52C) R X Ferrous chloride R R X R
Chloroform (PVDF, R to 125F/52C) X R R X Ferrous sulfate R R M R
Chlorosulfonic acid (100%) X X X X Fluoboric acid (CPVC / PVDF, R to 140F/60C) R R M R
________________________________________________
Chromic/sulfuric acid X X X X Fluosilicic acid
________________________________________________ R M M
Chromic acid (10%) R R R R Formaldehyde (PVDF, R to 120F/49C) R R R X
(PVDF& CPVC / PVDF, R to 120F/49C) Formic acid R R R X
Chromic acid (50%) (PVDF, R to 120F/49C) R R M R Furfural X M R X
(CPVC / PVDF, R to 70F/21C) Gallic acid (PVDF & CPVC / PVDF, R to 75F/24C) M R M R
________________________________________________
Citric acid R R R R Gelatin
________________________________________________ X R R R
Citric oils R R Glue P. V. A. M R R R
Copper chloride R R X R Glycerin R R R R
Copper cyanide R R R R Glycolic acid (PP, R to 70F/21C) R R R
Copper nitrate R R R R (PVDF & CPVC / PVDF, R to 75F/24C)
* Copper sulfate R R R R Glycols R M R
70
R = Recommended Use only explosion-proof motors on flammable liquids. Only metallic pumps should be used
M = Minor to moderate, should for transferring flammable or explosive liquids.
be field tested All pumps and containers must be properly grounded and bonded to prevent static discharge
X = Not recommended and sparking, which could cause electric shock, fire or explosion. A ground wire should be
= No data used on any explosion-proof motor as well as the container when transferring explosive material.
* = Flammable or explosive Always consult with a Safety Engineer for proper pump / motor selection.
3
ST
ST
CP
CP
PV
PO
PV
PO
AI
AI
VC
VC
NL
NL
DF
DF
LY
LY
/P
/P
ES
ES
P
P
(K
(K
RO
VD
RO
VD
SS
SS
YN
YN
F-
PY
F-
PY
TE
AR
TE
AR
LE
MA
LE
MA
EL
EL
)-
)-
NE
NE
X1
X1
31
31
MA
MA
-M
-M
75
75
6-
6-
X.
X.
F
F
AX
AX
MA
MA
17
17
(80
(80
.1
.1
X1
X1
30
30
C
F(
F(
75
75
F
F
)
80
80
F
F
(54
(54
C
(80
(80
)
)
C
C
)
)
)
* Heptane X X R X Muriatic acid (37%) (hot) R X R
* Hexane X X R X * Naptha X X R X
Hydrobromic acid M R X R * Napthalene X X M X
Hydrochloric acid (20%) R R X R Nickel chloride R R R R
Hydrochloric acid (37%) (cold)
________________________________________________ R R X R Nickel sulfate
________________________________________________R R R R
Hydrochloric acid (37%) (hot) R X R Nitric acid (5-10%) R R R R
Hydrofluoric acid (20%) R R X X Nitric acid (20%) R R R R
Hydrofluoric acid (50%) X R X X Nitric acid, (conc.) (PVDF, R to 120F/49C) X R R X
Hydrofluoric acid (75%) X R X X Nitric acid, red fuming X R X
Hydrofluoric acid (conc.) (cold)
________________________________________________ R X Nitrobenzene (PVDF, R to 75F/24C)
________________________________________________M R M X
Hydrofluosilicic acid (20%) R R X R Oleic acid R R R X
Hydrogen fluoride R R Oleum X X R X
* Hydrogen peroxide X X R X Oxalic acid (cold) (PVDF, R to 125F/52C) R R R R
* Hydrogen sulfide (cold) X X R X Palmitic acid M R R R
* Hydrogen sulfide (hot)
________________________________________________ X X R X Perchloric acid (PVDF, R to 125F/52C)
________________________________________________ R X M
Hypochlorous acid R X R Perchloroethylene X R R X
Iodine (PVDF, R to 150F/66C) M R X M Petrolatum R R R
* Isopropyl ether X X R X Phenol (carbolic acid) R R R R
* Jet fuel (JP3, JP4, JP5) X X R X Phosphoric acid (20%) R R M R
* Lacquer solvents
________________________________________________ X X R X Phosphoric acid (20%-40%)
________________________________________________R R R R
Lactic acid (PVDF & CPVC / PVDF, R to 120F/49C) R R R R Phosphoric acid (45%) R R M R
Lead acetate R R M R Phosphorus, red R
Lead sulfamate R Phosphorus, yellow R
* Ligroin X X R X Photographic solutions R R
Magnesium carbonate
________________________________________________ R R R R Plating solutions, chrome 40
________________________________________________R R R R
Magnesium chloride R R R R Plating solutions, copper R R R R
Magnesium hydroxide R R R R Plating solutions, gold R R
Magnesium sulfate R R R R Plating solutions, iron R R R R
Maleic acid M R R R Plating solutions, lead R R R
Mercuric chloride (dilute solution)
________________________________________________ R R X R Plating solutions, nickel
________________________________________________R R R
Mercuric cyanide R R R R Plating solutions, silver R R R R
* Methyl acetone X X R X Pl ating solutions, tin R R R R
Methyl chloride X R R X Plating solutions, zinc R R R R
* Methyl ethyl ketone X X R X Potassium bicarbonate R R M R
* Methyl isobutyl ketone
________________________________________________ X X R X Potassium bromide
________________________________________________R R R R
Methylene chloride X X R X Potassium carbonate R R R R
Milk R R R R Potassium chlorate R R R R
* Monoethanolamine X X R X Potassium chloride R R R R
Muriatic acid (20%) R R X R Potassium chromate R R M R
Muriatic acid (37%) (cold) R R X R Potassium dichromate R R R R
71
R = Recommended Use only explosion-proof motors on flammable liquids. Only metallic pumps should be used
M = Minor to moderate, should for transferring flammable or explosive liquids.
be field tested All pumps and containers must be properly grounded and bonded to prevent static discharge
X = Not recommended and sparking, which could cause electric shock, fire or explosion. A ground wire should be
= No data used on any explosion-proof motor as well as the container when transferring explosive material.
* = Flammable or explosive Always consult with a Safety Engineer for proper pump / motor selection.
3
CP LES R ) - AX.
CP
ST
ST
PO
PV
VC
PO
PV
AI
AI
VC
NL
N
DF
DF PYL
LY
LY
/P
/P
ES
P
P
VD
(K
(K
RO
RO
VD
SS
SS
YN
YN NE -
F-
F-
PY
TE
AR
TE
A
MA 6 - M F (80 )
LE
MA
E
EL
EL
)-
X1
NE
X1
31
31
MA
MA 130
75
-M
75
6-
M
F 175
X.
X.
F
AX
MA
17
17
(80
(80
AX
.1
X1
5
30
C
F(
75
)
F
F
)
80
F
(54
(54
F(
C
C
(80
80
)
C
C
C
)
)
Used for the addition of acids and bases to plating solutions, neutralization of waste
streams, chemical reactions, cooling tower and boiler feed preparation, process control
monitoring and recording.
FEATURES
An In-range output option is perfect for control-
ling a solenoid valve to meter in or dump a batch
treatment tank when the pH is within preset
limits.
4
BENEFITS
Improve treatment consistency
Measure pH or mV
Easy to install
Simple to operate
'WPH' Series pH/ORP on-line process controllers 'WPH' Series controllers are available with either
will improve your treatment performance. Micro- on/off mechanical relay outputs or direct pulse pro-
processor-based, with a very easy-to-use menu portional control for metering pumps. Installation is
format, 'WPH' Series controllers measure in pH or mV as easy as unpacking the unit, mounting it and
accurately and reliably. A versatile output configuration plugging it in. We also offer other wiring options to
allows you to program up to four outputs in a variety fit your requirements.
of ways with just one controller.
Microprocessor-based with intuitive menu format At-a-glance status display - Look at any set point
- No potentiometers to adjust, all set points are known without interrupting control or needing the access
precisely, no repetition of adjustments is necessary. code. Able to view:
Analog graph relative to set points
pH or ORP measurement is congurable via a soft- pH-ORP values
ware menu setting - Reduces inventory requirements. Status of alarms, outputs
4
Versatile relay conguration - Control outputs can Calibration reminder - Calibration menu displays
be set as high or low set points via keypad. Auxiliary the date of the last sensor calibration and allows
outputs can be set as: the user to set the number of days between calibra-
High alarm Low alarm tions. The controller will prompt the user to perform a
In-range output Out-of-range alarm calibration at the specied time.
Probe wash
Self diagnostics - Software and electronics are
Probe wash feature - For applications that require constantly monitored, without having to take the
frequent electrode cleaning, automatic probe wash controller off line. Any operator-action-needed mes-
stretches out reliable measurement life between sages are displayed in plain English. A fth relay is
maintenance interruptions. activated by any diagnostic failures.
Simple, plug-in installation - Prewired, wall mount Programmable access code - secures set point
NEMA 4X enclosure is easy to mount, includes power parameters. Program any four digit access number
cord and pump connections, reduces installation cost. or disable the code requirement entirely.
Hardwired versions are available.
Self test - selected via menu, a simulated pH and
Auto buffer recognition - software selectable for temperature signal is input to the controller. This on-
U.S. or European calibration standards, or disable line diagnostic allows sensor or controller problems
entirely for manual calibration. to be deciphered quickly.
WATER
METER
W-PH CONTROLLER
SOLENOID
VALVE
HEAT
EXCHANGER
SAFETY APPROVALS
The W-PH Series controllers are in compliance with the following safety and performance standards:
U.S., Product Safety: UL508
Canada, Product Safety: CSA C22.2 #142
European Community (CE), Product Safety: Low Voltage Directive (72/23/EEC)
Performance: Electromagnetic Compatibility: EMC Directive (89/336/EEC)
92 V (1 mV displayed) (ORP)
Accuracy (Calibrated) .01 pH Operating Ambient 32 to 158F (0 to 70C)
Temperature
Temperature Comp. (opt.) 1000 ohm platinum RTD Storage Temp. -20 to 180F (-29 to 80C)
Temperature Range 32 to 212F (0 to 100C) Shipping Weight 10 lbs (approximately)
Temperature Resolution .09F (.05C)
Temperature Accuracy .9F ( .5C) OUTPUTS
Control (On/Off) Internally powered relays
INPUTS @ 115 VAC, 10A resistive, 1/8 HP
Power Controller 115 VAC 15% @ 230 VAC, 6A resistive, 1/8 HP
or 230 VAC 15%
Power pH Preamp 5 VDC, 5 mA Control (proportional) Opto-isolated open collector
(supplied by controller) 50 mA, 20 VDC maximum
VLOWMAX = 1.0V @ .4mA, 1.75 V @ 30 mA
Signal pH/ORP 1500 mV
Temperature Comp. (opt.) Pt 1000 AUX1, AUX2, Alarm Dry contact relays
Interlock (opt.) Isolated dry contact closure @ 115 VAC, 10A resistive, 1/8 HP
required (i.e. ow, level, etc.) @ 230 VAC, 6A resistive, 1/8 HP
W-PH CONTROLLER
AC POWER
FLOW IN
FLOW OUT
SUBMERSION
ELECTRODE
ACID BASE
DIMENSIONS
CONTROLLER PREAMPLIFIER
7.25"
4.0" 5.0"
5.0" 3.12"
6.75"
FRONT VIEW SIDE VIEW
7.5"
4.87" 2.06"
.313" DIA.
THRU HOLE 2.25"
4.43"
4
SIDE VIEW BOTTOM VIEW MOUNTING
FRONT VIEW FOOTPRINT
ORDERING INFORMATION
W-PH3 0
(Control) (Voltage) (Outputs) (Option)
For use in the addition of acids and alkalies to plating solutions, neutralization
of waste streams, chemical reactions, cooling tower and boiler feed
preparation, process control monitoring and recording.
MODEL 440 pH CONTROLLER / MODEL 443 ORP CONTROLLER - For use indoors
ideal for panel or wall mounting. Output power is wired 443 ORP 56-0044
to a grounded output receptacle at bottom of case.
* For 220V/1/50, add C to Price Code No.
MODEL 443 ORP CONTROLLER is designed to
provide addition of oxidation/reduction agents to pro-
cess streams. It is possible to control chlorine or sulfur OPTIONAL
dioxide gas or liquid sodium hypochlorite, sodium Dual set point add 56-0200
thiosulfate or chromic acid additions and DTC type
metal precipitants.
With single, dual, triple or quad TO ORDER, use Price Code No.
setpoints PRICE
MODEL
Weatherproof case CODE NO. *
Similar to Models 440 & 443 436-pH 56-0065A
436-ORP 56-0065B
MODEL 436 pH and ORP CONTROLLERS
* For 220V/1/50, add C to Price Code No.
are designed for outdoor and corrosive at-
mosphere environments. The case is NEMA OPTIONAL
4x rated to protect the instrumentation from
Dual setpoint add 56-0200
corrosion. Combination electrodes are used
Viewing window in cover add 56-0089
with both pH and ORP. Function and major
features are the same as parallel Models Audible alarm add 56-0139
440 and 443 above. (Requires add'l setpoint)
Automatic temperature
add 56-0179
compensation
FEATURE MODEL 440 pH MODEL 443 ORP MODEL 436-pH MODEL 436-ORP
Accuracy Meter + 0.2 pH Meter + 15 mv Meter + 0.1 pH Meter + 5 mv
pH meter (ORP meter) 5.5" taut-band movement
pH range (ORP range) 0 to 14 pH 0 - 1000 mV, 10 mV div. 0 to 14 pH 0 - 1000 mV, 10 mV div.
Setpoint range 2 to 12 pH 0 - 1000 mV 2-12 pH, accuracy + 0.2 pH 0 - 1000 mV
Setpoint stability + 0.05 pH per month + 5 mV per month + 0.05 pH per month + 5 mV per month
Input current 2 picoamperes maximum
Temperature compensation 0 C to 100 C in 2 C divisions
pH electrode connector Teflon insulated BNC
Reference electrode connector Pin jack
Automatic temp. compensation connector Standard phone jack
Electrode to controller distance 100 ft. nominal w/o preamp
Power requirements 115 V/1/60, 10 watts 115 V/1/60, 8 watts
Single, 115V AC 5 amp controlled by the setpoint.
Output
May be alarm to indicate on or off condition. Front panel indicator light.
Fuses One 5 amp on pump circuit (1/6 HP motor load), one 1/4 amp for controller electronics
Size 13" high x 9" wide x 3" deep 12" high x 10" wide x 6" deep
Weight 4.3 lbs. 12 lbs.
Designed for panel or wall mounting. FRP NEMA 4X. Up to four setpoints may be
Case Requires 12-1/8" x 8-1/8" panel cut out. provided. Neoprene door gasket with all inputs
Aluminum with baked enamel finish. and outputs through the bottom of the case.
77
MODEL 432 MONITOR pH or ORP RECORDER/CONTROLLER - For process, reaction and waste water
Two set points: one for recorder, Weatherproof FRP NEMA 4x case
one for recorder/controller, with Simple installation
space for two optional setpoints
and timer Select options and electrodes to
suit your needs
MODEL 432 pH or ORP RECORDER/CON- If only acid or alkaline is to be added for neutral-
TROLLER has two independent measuring chan- ization, only one setpoint will be connected to the
nels - one with analog meter and the other with a meter and the other can be used as high alarm or
chart recorder. Each channel is used with its own recorder.
probe monitoring two separate locations, or both Hexavalent chrome or cyanide destruct is
channels can share a common probe. The Model accomplished by ORP. In this case, only one
432 is available as either a pH or ORP instrument. setpoint is needed and only one reactant is added.
Two setpoints are standard. Setpoint relays can activate metering pumps, so-
4
The setpoints may be used as high / low when lenoid valves or alarms. Two additional setpoints
both acid and alkaline additions are needed as in can be added for maximum versatility. The optional
a neutralization tank. The second probe can then pulse timer prevents over-dispensing of reactant
be placed in the effluent stream to record final pH. due to a probe or circuitry failure.
PRICE
TO ORDER, use Price Code Number OPTIONAL CODE NO.
MODEL POWER CODE NO. WEIGHT Additional setpoints, to 5 total add 56-0200
PRICE SHIPPING Dual channel setpoint for recorder add 56-0140
432-pH 115V/1/60 56-0066
115V/1/50 56-0066B Viewing window in cover add 56-0089
220V/1/50 56-0066C Adjustable pulse timer,
25 lbs. add 56-0141
432-ORP 115V/1/60 56-0142 0 to 60 seconds on and off
115V/1/50 56-0142B Audible alarm (Requires add 56-0139
220V/1/50 56-0142C additional setpoints)
MODEL 437 pH or ORP RECORDING CONTROLLER (Similar to Model 436 except has chart
recorder instead of analog meter.)
MODEL 400 pH MONITOR RECORDER - For continuous pH recording of waste or process streams
APPLICABLE TO PRICE
ITEM AND DESCRIPTION MODEL NOS. CODE NO.
DUAL CONTROL OPTION - Includes a second DPDT relay and a second setpoint control. Valuable when 436, 437, 440, 443 56-0200
adding to solutions. 432, 436, 437 56-0201
- Specify this option when second setpoint is to be wired to the recorder - useful as an alarm or to
432 56-0202
control the addition of a final neutralization treatment.
- Specify this option when second setpoint is to be used as an over-range safety shutoff in the event
fouling of the electrode poses a problem. The recorder setpoint is connected in series with the con- 432 56-0203
troller setpoint. The recorder setpoint is then adjusted 1 or 2 pH units beyond that of the controller.
ADJUSTABLE CYCLE TIMER - A solid state timer which will start timing when the setpoint is reached.
At any preset point between 0 and 50 minutes, the timer will reverse the output relay. This safety
432, 436, 437, 440 56-0204
feature is designed to stop an acid pump in a closed system in the event of a mechanical or elec-
trode failure.
Base 56-0207 +
BNC to BNC EXTENSION CABLE (to 100 ft. maximum) 400, 432, 436, 440, 443
56-0207A per ft.
pH / ORP CHART PAPER (inkless 30 day)- 50 divisions, 63 foot roll 400, 432, 437 56-0211
ELECTRODE FILLING SOLUTION 56-0304A
79
Double junction design Features a peripheric junction combination pH 3/4" Pipe socket
electrode housed in a CPVC immersion assembly
Sealed peripheric junction and can be replaced in a matter of minutes without
4
combination pH electrode tools. The special peripheric reference junction is
with extension cable and spade designed in an annular form around the pH measur-
lug connections ing electrode.With this special junction design, it will
Annular non-fouling reference allow operation where sulfides, heavy metals, etc.,
junction would normally foul a standard combination elec-
trode reference. This immersion assembly
Removable guard for ease of will satisfy the requirements of almost any 3'
cleaning continuous process application in which
Permits use where high solution a pH electrode must be submerged into a
currents prevail tank, trough or manhole. ORP 5000 mV, Electrode
Easy mounting pH 0-14, Temp -5 to 100oC. protected in
CPVC 36" x 3/4" NPT pipe extension and 10' Extension CPVC gland
cable housing 6"
terminal with terminal strip for No. 6 spade
lug connector and junction box. 10' extension
cable (BNC to spade lug). Available with
8" x 3" x " PVC mounting bracket.
CPVC electrode gland
CONDUCTIVITY CONTROLLER
What it does -
The CC-97 and CC-95 controllers are fully automatic systems
which will greatly reduce the amount of water used in continuous
flow rinse tanks. At the same time, they automatically maintain
water quality, ensuring effective rinsing in water up to 180F
(82C).
How it works -
The three parts of the system are easily installed. Submersible
conductivity sensor is adjusted to either of the two microsiemen
TYPICAL INSTALLATION
scales and immersed in rinse tank. Controller set-point is then
selected. Generally, rinse water contamination is caused by
chemicals being "dragged in" and salts that are dissolved from
the parts being rinsed. These solutions ionize and can be mea-
sured and controlled by their electrical conductivity. Rinse water
cannot flow into the tank until the contamination level rises above
the set-point. Sensor then signals for solenoid valve to open and
add fresh water. When the dilution lowers the contamination to
below the set-point, the solenoid valve will close. Indicator lights
on controller signal operating power and valve position.
WATER CONDUCTIVITY
ppm Water
(NaCl) Microsiemens Quality
1 - 150 2 - 300 D. I.
10 - 20 20 - 40 Demineralized
20 - 100 40 - 200 Soft
100 - 300 200 - 600 Medium
300 + 600 + Hard
MODEL CC-95 PANEL MOUNTED SYSTEM
For specifications, refer to next page.
81
SPECIFICATIONS
4
Shipping weight Wall mount - 8 lbs. (3.6 kg) Panel mount - 5 lbs. (2.3 kg)
Ranges 5-500 micromhos (for high quality water)
500-5000 micromhos (for normal tap water) } eld select
ON - OFF span Approximately 5% of set-point
SUBMERSION SENSOR
Temperature compensation Automatic to 180 F (82 C)
Materials Epoxy and 316 stainless steel
Cord 10 foot (3 M ), 22 ga., 4-conductor, vinyl jacketed
Solenoid valve operating pressure 10 - 100 PSI (69-690 kPa)
SOLENOID VALVE - Nylon (glass reinforced), 24 VAC
Operating pressure 10 - 100 PSI (69-690 kPA)
Connections 1" NPT inlet, 1/2" NPT conduit
What it does -
The CCM-57 Monitor / Controller is a precision instrument which
accurately measures solution conductivity in a variety of micro-
siemens ranges. It is ideal for reverse osmosis water treatment
systems, as well as applications in laboratories, plating, electronics
production and general industrial process control. The CCM-57
is exceptionally reliable and includes many convenient features
such as push button set-point check. When used as a Monitor/
Controller, optional solenoid valve and transformer are required.
Signal to audio or
visual alarm How it works -
Rugged 316 stainless steel sensor is mounted in a pipeline tee
or directly in the side of a tank. The attached sensor cable (10'
4
MODEL CCM-57 MONITOR (When used as controller, order optional solenoid valve and transformer)
CONTROLLER - NEMA 3 panel mount with optional wall mount brackets
Readout 2" (63 mm) analog meter
Accuracy 2% of span
Sensitivity 0.05% of span
Repeatability 0.1% of span
Calibration check Built-in (push to test)
Voltage output for chart record- 0-10 VDC @ 5 mA max. (linear)
er Single set-point control continuously adjustable 0-100% of full scale
Indicators: ABOVE (red) and BELOW (green) set-point LEDs
Relay function for alarm Contact rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates increasing or
decreasing reading (selectable)
Input power 115 VAC, 50-60 Hz, 15% (user changeable to 220 VAC)
Maximum power consumption @ 115V; 3 watts (25 milliamps)
Dimensions 6" (152 mm) H x 4.8" (122 mm) W x 3.8" (96 mm) D
Ambient temperature range -22o F (-30 C) to 140 F (60 C)
Shipping weight 2 lbs (0.9 kg)
IN-LINE SENSOR
Temperature compensation Automatic to 77F (25C) between 32 to 212 F (1 - 100C)
Pressure / temperature limits 100 PSI (690 kPa) @ 212 F (100C)
Bushing Polypropylene threaded 3/4" NPT
Materials 316 stainless steel, EPDM, TFE
Cable 24 ga. shielded; 10' (3 meters) standard
Dimensions Metal portion 1.2" (30 mm) L; 0.5" (13 mm) diameter
OPTIONAL SOLENOID VALVE - Nylon (glass reinforced), 24 VAC with separate 115V to 24V transformer
Operating pressure 10 - 100 PSI (69-690 kPA)
Connections 1" NPT inlet, 1/2" NPT conduit
Output to valve 24 volts @ 600 milliamps AC (115V to 24V transformer included)
IDEAL FOR:
ANODIZING;
PULSE PLATING;
ZINC, NICKEL, CHROME
& PRECIOUS METAL
4
ELECTROPLATING
The Series 1200 system is suitable for 1 - 99,999 Eliminates manual additions
amp rectifiers. The unit features keypad data in- Increases safety and precision of operation
put for user programming of shunt current rating, Verifies metal consumption
ampere-hour or ampere-minute totalizing, totalizer
Activates electronic pulse or motor driven pumps
reset, preset reset and preset values plus factory /
field calibration. Internal circuitry converts an input Eight digit LED display
signal to activate pump(s) at a near continuous flow Digital totalizing Ampere-Time
rate determined by the user programmed setting. System accuracy + 0.5%
Temporary power loss does not affect last totalizer
Programmable for Amp-Hours or Amp-Minutes
reading.
Programmable for millivolt and current values
Status indicators include: of shunts
8-digit LED display shows power is supplied Brightener is replenished at precise rate of
Ampere-Hour or Ampere-Minute LED display con-sumption in relation to metal deposited,
Program LED shows unit is in programming automatically compensating for variation in work
mode and not running load or rate. Compact solid state circuitry is pro-
tected in a corrosion resistant plastic case. System
Preset LED shows a preset event has
occurred includes an 8 foot, 3-wire cord and molded plug.
TO ORDER
PRICE CODE NO.
SERIES 1200 56-0578
OPTIONS
AMP-SENTRY TOTALIZER
INSTRUMENTATION A-306K
4
FEED PUMP PULSING AND CHEMICAL ADDITIONS
These high performance electronic flow monitoring/ mixing applications or triggering acid and caustic
control systems consist of three components: feed pumps. They can also be interfaced with other
1. Flow Meter instruments in your plant, including a computer.
2. In-line/Insertion Flow Sensor The accuracy and reliability come from patented
3. Installation Fitting Flow Sensor designs that convert fluid velocity in a
A variety of different configurations is available to pipe into an electronic signal. The signal is measured
provide a system that will monitor or control the and channeled through microprocessor based solid
movement of fluids and is compatible with corrosive state circuitry to the appropriate meter: flow rate,
chemicals. The instruments are waterproof for long totalizer or controller.
life in shop environments. Cost effectiveness of this equipment makes plant
applications feasible. The initial investment pays
A system may be assembled to monitor a process
for itself quickly by providing cost savings from
flow rate (GPM, LPM or any other units) or keep track
improved process efficiency. These systems are
of accumulated flow for a period of time (totalize
an excellent choice for the simple to the complex
gallons or liters). Instruments can be selected that
industrial application.
provide a pre-set electrical output signal for batch-
86
PRICE
Factory Mutual (FM) approved for
MODEL intrinsic safety in Classes I, II
CODE NO.
and III, Division I
4
509 56-0576
Environmental:
SERFILCO Operating temperature: 14F - 149F
Display:
Type:Taut-band suspension meter movement,
SPECIFICATIONS: 250 deflection - not suitable for prolonged
Compatible sensor: Model 515 exposure to vibration.
Minimum full scale range: 7 fps Dials:
Accuracy: 2% of full scale Reversible dial kit included (0-2, 4, 6, 8, 10, 100)
Repeatability: 1% of full scale Electrical power: none required
* For PVDF sensor change P to N in model and add -N to price code No.
PRICE PRICE
DESCRIPTION DESCRIPTION
CODE NO. CODE NO.
Surface mounting bracket 56-0571 Power supply
Splashproof rear cover kit 56-0573 120 / 220 VAC-24 VDC (5600 & 855) 56-0758
120 VAC - 24 VC (5600 only) 56-0757
87
4
and four button keypad arrangement
5600 56-0752
is user friendly.
PANEL MOUNT
The Model 855 Flow Transmitter is Permanent and resettable total-
an advanced, cost effective instru- izers
ment that converts the flow sensor Isolated 4 to 20 mA output, fully
signal into a 4 to 20 mA signal for long adjustable and reversible
distance transmission. Configuration
flexibility is maximized with two pack- Two optional SPDT relays: Hi, Lo,
aging options for field mounting or Pulse, Off (Max. 300 pulses / min.)
panel installation, two optional relays 2 x 16 ohmeter LCD display
for process control and scalability for Power: 12 to 24 VDC 10%, regu-
virtually any flow range or engineering lated
unit. State-of-the-art electronic design
ensures long term reliability, signal Field mount includes universal
stability and simple user set-up and mounting kit
operation.
FIELD MOUNT
MOUNTING DESCRIPTION MODEL PRICE
VERSION CODE NO.
Panel Flow transmitter 855-1P 56-0753
Panel Flow transmitter with 2 relays 855-2P 56-0754
Field Flow transmitter 855-1F 56-0755
Field Flow transmitter with 2 relays 855-2F 56-0756
NOTE:
All scale ranges shown are examples. When ordering installation fittings, please
specify desired scale range. Instrument bodies measure 3.8" x 3.8" x 3.5" and
include panel mounting hardware (except Model 855 field mount and Model
815-PO integral mount).
88
5
A SER-DUCTOR system provides solution agitation plating bath or other process solution, it is only this fluid
with a centrifugal pump by drawing liquid from a tank and that is recirculated by the SER-DUCTOR system.
returning it to the tank through a sparger system, similar
to that used for air agitation, with eductors strategically SER-DUCTOR agitation in a process tank keeps
placed along the sparger pipe. particulate from settling to the tank bottom where it can
SER-DUCTOR agitation delivers 5 times the pump form a layer of sludge that shortens the life of the solution,
output at each nozzle.It effectively distributes the desired requires expensive dumps, new make-ups and costly
level of agitation to critical areas in your process tank. downtime in between for manual cleanout of the tank
The system is driven by your choice of vertical, magnetic bottom. By effectively keeping the "dirt" in suspension,
drive, self-priming or mechanical seal pump. the SER-DUCTOR system makes it easier for a filtration
system on the tank to remove particles. This extends
With SER-DUCTOR systems, solutions are agitated the life of the bath and greatly reduces the possibility of
without the introduction of foreign matter such as airborne contamination being carried to other tanks in the process
dirt or compressor oil, as is often the case with air cycle where it can lead to costly rejects and even product
agitation. Whether the solution is a cleaner, a rinse, a failure.
PRINCIPLE OF OPERATION
DIFFUSER
NOZZLE
Liquid pumped into the eductor nozzle exits at high
velocity, drawing an additional flow of the surrounding
solution through the eductor. This additional flow (induced
liquid) mixes with the pumped solution and multiplies its
volume five-fold. The source of the pumped liquid (input) INPUT
can be a pump or filter chamber discharge. EACH GALLON OF
OUTPUT
PRESSURE LIQUID
INDUCES FIVE GALLONS
FOUR GALLONS RECIRCULATED
OF LIQUID
TYPICAL APPLICATIONS
For mixing
Vigorous SER-DUCTOR agitation within the tank creates
sufficient solution movement to eliminate solution strati-fica-
tion. This movement lends itself to mixing two or more liquids
or to mixing a liquid and a powder. (A more extreme angle
of eductor positioning is helpful in mixing bath components
and assuring continuing uniformity of the solution.)
91
SER-DUCTOR NOZZLES
5
1/4" PP NOZZLE 3/8" PP NOZZLE 3/4" PP NOZZLE
COUPLING SIZE - FNPT PRICE CODE NO. PRICE CODE NO. PRICE CODE NO.
3/4" 33-7003 33-6098
1" 33-7004 33-6022
1-1/4" 33-7005 33-6099 33-6024
1-1/2" 33-7000 33-6025
2" 33-7001 33-6026
PRE-ENGINEERED SYSTEMS
'EH'
vertical
'F' magnetic-coupled 'HE' horizontal
1-5
Request appropriate bulletin for complete specifications, including alternate materials of construction, flow curves, dimensions, etc.
1 2 3 4 5
Bulletin P-312 Bulletin P-301 Bulletin P-509 Bulletin P-621 Bulletin P-201
6
Total dynamic head (TDH) in feet 2.31 = PSI
93
MIXERS A-403H
TYPICAL APPLICATIONS:
WASTE TREATMENT
FOOD PROCESSING
COSMETICS
DIRECT DRIVE CHEMICAL MANUFACTURING
MIXER PHARMACEUTICALS
PAINTS AND INKS
5
C-clamp Pumping rate to 5600 GPM
mount
(standard) Single or dual propeller configurations
Variable speed drive available for shear
sensitive liquids
SPECIFICATIONS
For gear or direct drive model, select mixer, single or dual propeller and motor from tables below.
EXAMPLE: Mixer + Propeller + Motor = Model = PRICE CODE NO.
+ 50-1041D
SMG75 + 1 D = C -CLAMP MOUNT MODEL - SMG75-1-G.75 =
SERFILCO DOUBLE REDUCTION HELICAL GEAR DRIVE MIXERS, AGMA quality 8, provide smooth, quiet perfor-
mance. They offer the ability to change mixer speeds from 310 RPM to 170 RPM (standard operating RPM is 310) by simply
replacing the primary gear set. Heavy duty design offers more mixing capability than any other portable mixer. Standard shaft
length is 36. Consult Sales Dept. for other lengths.
SERFILCO DIRECT DRIVE MIXERS utilize a precision-bored shaft chuck connected directly to a 56C frame motor. Perma-
nently lubricated chuck support bearing and elastomeric lip seal with garter spring means no contamination from lubricants and
no maintenance. Operating RPM is 1750. Minimum shaft length is 36. Consult Sales Dept. for other lengths.
1
Data based on 100 CPS viscosity and specific gravity
approximately equal to 1.0. NOTE: When the tank height is greater than 1 times the tank
2
Includes air flow control valve, filter oiler lubricator. For diameter, dual propellers should be used to assure complete mix-
other conditions, consult Sales Dept. ing. The second propeller is generally located midway between
3
For optional swivel cup mount, add C to basic Model Num- the bottom propeller and the liquid surface.
ber and change 1 to 2 after hyphen in Price Code Number. See Technical Bulletin TA-105 for selection guidelines.
95
SELECTION GUIDELINES
The following guidelines and selection tables are based Proper matching of propeller and motor is usually based
on mixing in vertical cylindrical tanks with flat, dished or on the turnover, or pumping rate, for the application.
shallow cone bottoms. Mixer selections may vary with (Polymer mixing is an exception.)
tank shape, retention times, starting conditions, etc.
Pumping rate is arrived Propeller horsepower require-
at by the following: ments can be calculated from:
Q=NQ N d HP=Np P N d5
231 1.53 x 1013
For liquid levels .5 to 1.1
times the tank diameter, a WHERE: WHERE:
Q = pumping rate in gallons per HP = horsepower required
single propeller is suitable. minute
5 N = mixer speed in RPM
to N = mixer speed in RPM
15 d = propeller diameter in inches
A single propeller may be lo- d = propeller diameter in inches P = specic gravity of mixture
cated from .5 to 2.0 propeller H NQ = pumping coefcient for Np= power coefcient for a class of
diameters off the tank bot- SPACING propeller type (1.0 or propellers (1.0 or square
square pitch marine pitch marine propellers,
tom. The optimum distance is propeller, NQ =.5) standard
d Np =0.35) standard
one(1) diameter off the bot- 1xd
5
(1.5 steep pitch marine (1.5 steep pitch marine
tom. (Example: 10 diameter D propeller, NQ =.77) optional propellers, Np = 0.85) optional
prop, should be approximate-
ly 10 off the tank bottom)
SELECTION TABLES
Two or More Liquids (Blending)
For liquid levels 1.1 to 1.6 times the tank diam- PRODUCT VOLUME (GALLONS)
eter, dual propellers are recommended. VISCOSITY 30-50 75-100 200-400 500-750 1000-1500 2000-3000
Up to 100 cps SMD25 SMD25 SMD33 SMD75 SMG33 SMG75
When dual propellers are required, spacing 250-750 cps SMD33 SMD50 SMD75 SMG33 SMG75 SMG150
between gear-driven mixer propellers should 1000-2500 cps SMG25 SMG50 SMG50 SMG100 SMG150 SMG200
be approximately two (2) propeller diameters: 3000-4000 cps SMG33 SMG50 SMG75 SMG100 SMG200 *
propeller spacing for direct-drive mixers should 5000 cps SMG100 SMG150 * * * *
be 4 to 5 propeller diameters. Shear Sensitive
* SMG25V SMG50V SMG100V SMG150V *
(Polymers)
Blend times for the selections above are generally 5-15 minutes. * Consult Sales Dept.
V =Variable speed
The mixer position in an un-
baffled tank should be as Liquid - Solids/Slurries
shown for maximum turn- PERCENT VOLUME (GALLONS)
over of liquid and optimum 15 to SOLIDS
30 BY WEIGHT 30-50 75-100 200-400 500-750 1000-1500 2000-3000
mixing. Positioning the pro-
5 - 10% SMD25 SMD25 SMD50 SMD100 SMG33 SMG75
peller on center will pro-
15 - 20% SMD33 SMD75 SMD100 SMD200 SMG150 *
duce a vor tex which may
25 - 40% SMD50 SMD100 SMG50 SMG100 * *
help in wetting and dispers- 50 - 75%
ing light solids. SMG25 SMG50 SMG100 SMG150 * *
(Ceramic slip)
1. For wetting light solids, position mixer prop near center of tank to produce a vortex.
Mixer position in square and 2. For flocculation or solid dispersion consult Sales Dept.
3. Whenever liquid depth to tank diameter ratio exceeds .75 use dual props.
rectangular tanks is similar
to cylindrical tanks. When L
is more than 2 x W, consult Waste Treatment Mixer Selections
your SERFILCO represen- TANK WASTE FLOW RATE (GPM)
tative. VOLUME
GALLONS 10 25 50 100
100 SMD25 SMD33 SMD50
*
250 SMD25 SMD25 SMD33 SMD50
500 SMD33 SMD50 SMD100 SMG33
1000 SMG25 SMG25 SMG33 SMG50
2000 SMG33 SMG50 SMG50 SMG75
3000 SMG50 SMG75 SMG100 SMG100
* Consult Sales Dept.
96
Pre-engineered packages
Chemical resistant
5
M IXING
T ANK
A
M IXING
B T ANK
F ILTER
P UMP
PUMP PRIMING ADDING CHEMICALS PRECOATING A FILTER CLEANING A TANK,
Pumps can be primed by rst TO SOLUTIONS Provides a convenient way to add BOILER or
recirculating solution between the Chemical additions to solutions lter aid (precoating) to a lter COOLING TOWER
mixing tank and the pump. Partially being pumped can be made di- support membrane and to provide Provides easy descaling, rins-
open valve B to remove air from the rectly by placing the chemicals in the additional lter aid and carbon as ing and ushing with or without
suction hose. mixing tank and opening valve A. required. a lter.
For SERFILCO pump selection, see Bulletins P-203 (HC/HK), P-201 (HE), P-504 (D), P-509 (M), P-621 (F)
HEATERS and 98
LISTED CERTIFIED
Heaters
QUARTZ METAL L-SHAPED TEFLON Available in a variety of configurations in steel,
SPIRAL
6
TEFLON HEAT
FLAT PROFILE EXCHANGER
6
Be certain heater is properly Junction box must not be sub-
connected in compliance with merged.
80 -- 130 .16 180 .50 all codes and per instructions
85 .01 135 .18 185 .55 which accompany heater.
90 .02 140 .21 190 .60 Solution level must always
remain above heated zone of
95 .04 145 .24 195 .66 heater. Cold zone
100 .05 150 .27 200 .72 Bracket
Heater should remain at least
105 .065 155 .30 205 .80 2" above sludge at bottom of
110 .09 160 .34 210 .87 tank. Heated zone
115 .10 CAUTION: All heated tanks
165 .37 215 .95 should be equipped with an
120 .12 170 .41 220 1.04 emergency automatic shut-off
125 .14 175 .45 device.
Solution level must be at least
one inch below junction box.
SINGLE ELEMENT SPIRAL Compatible with most plating tank solutions, SINGLE ELEMENT SPIRAL
OVER - THE - SIDE inert to acids, anodizing and pickling solutions L-SHAPED TEFLON
TEFLON IMMERSION up to 212F. temperature. Check Chemical IMMERSION HEATERS
HEATERS Resistance Chart or with chemical supplier for
proper material selection.
Replaces alumina or graphite heaters.
FEATURES:
Low watt density for long service life.
Non-contaminating Teflon covered
stainless steel elements. LENGTH
LENGTH
PTI or PTLI thermal protection standard.
HOT
ZONE Grounded internal metal element for safety.
HOT ZONE
U.L. listed, CSA certified.
Lightweight, non-floating construction.
Standard 3' flexible PVC liquid-tight conduit.
Polypropylene or Teflon guards optional.
10 watts/square inch nominal. Consult Sales Dept. Bottom design for even heating and
240 volts standard as listed - varying liquid levels.
Single phase only
other voltages available.
Longer lengths available.
Vapor-tight polypropylene terminal enclosure.
WATTS VOLTS* ZONE LENGTH CODE WT. WATTS VOLTS* ZONE LENGTH CODE WT.
Inches Inches NUMBER lbs. Inches Inches NUMBER lbs.
500 240 5 11 79-1000XAA1 6 500 240 6 12 79-1009XAA1 6
1,000 240 7 11 79-1001XAA1 7 1,000 240 8 12 79-1010XAA1 7
2,000 240 11 17 79-1002XAA1 8 2,000 240 12 18 79-1011XAA1 8
3,000 240 15 23 79-1003XAA1 13 3,000 240 17 18 79-1012XAA1 13
4,000 240 19 29 79-1004XAA1 15 4,000 240 20 18 79-1013XAA1 15
5,000 240 24 35 79-1005XAA1 18 5,000 240 24 18 79-1014XAA1 18
6,000 240 29 40 79-1006XAA1 21 6,000 240 29 18 79-1015XAA1 21
8,000 240 37 47 79-1007XAA1 25 8,000 240 37 18 79-1016XAA1 26
9,000 240 44 54 79-1008XAA1 28 9,000 240 44 18 79-1017XAA1 29
* Consult Sales Dept. for other choices.
#3 PROTECTOR
#1 HEATER MATERIAL #2 VOLTAGE Consult Sales Dept.
#4 PHASE
1 = 1
A = 240V
X = PTFE (Teflon) A = to 1800 F 3 = 3
B = 480V Replaceable
Q = Quarts PI B = 180-2300 F #5 OPTIONS
C = 120V
P = Plain steel C = 230-3000 F Blank = No guard
D = 208V
F = 304 stainless steel D = to 180OF C = w/guard
E = 415V Resettable
S = 316 stainless steel PII or PIII E = 180-230OF G = Guard only
G = 600V
T = Titanium F = 230-300OF J = Tube only
H = 380V
E = Element only
101
SINGLE ELEMENT FLAT Compatible with most plating tank solutions, SINGLE ELEMENT FLAT
OVER-THE-SIDE TEFLON inert to acids, anodizing and pickling solutions L-SHAPED TEFLON
up to 212F. temperature. Check Chemical IMMERSION HEATERS
Resistance Chart or with chemical supplier for
proper material selection.Replaces alumina or
graphite heaters.
FEATURES:
LENGTH Low watt density for long service life.
6
Consult Sales Dept. ages available.
Low profile bottom design for even
Single phase only
heating and varying liquid levels.
Grounded internal metal element for safety.
6
HOT HOT
LENGTH* PRICE CODE SHIP LENGTH* PRICE CODE SHIP
WATTS VOLTS* ZONE WATTS VOLTS* ZONE
inches NUMBER WT. lbs. inches NUMBER WT. lbs.
inches inches
500 240 6 10 79-1136QAA1C 9 1,500 240 6 10 79-1152QAA1C 21
Single phase standard. Consult Sales Dept. for optional Standard design consists of three individual single phase heaters,
3 phase. which can be wired delta in the eld to achieve a three phase
* Consult Sales Dept. for other choices. balanced operating system. Individual elements are eld replaceable.
104
OVER-THE-SIDE HEATERS (OTS) STEEL, STAINLESS STEEL
- Tubular and TITANIUM A-102M
LENGTH
LENGTH
FEATURES: HOT
ZONE
HOT Heavy duty, long lasting construction.
ZONE
PI thermal protection standard
HOT HOT
LENGTH1 316 STAINLESS SHIP LENGTH1 316 STAINLESS SHIP
WATTS VOLTS1 ZONE WATTS VOLTS1 ZONE
inches STEEL2 WT. lbs. inches STEEL2 WT. lbs.
inches inches
1,000 240 6 11 79-1168SAA1 7 3,000 240 6 11 79-1178SAA1 21
2,000 240 10 17 79-1169SAA1 10 6,000 240 10 17 79-1179SAA1 30
3,000 240 16 23 79-1170SAA1 11 9,000 240 16 23 79-1180SAA1 33
4,000 240 20 29 79-1171SAA1 13 12,000 240 20 29 79-1181SAA1 39
5,000 240 25 35 79-1172SAA1 15 15,000 240 25 35 79-1182SAA1 45
6,000 240 30 40 79-1173SAA1 17 18,000 240 30 40 79-1183SAA1 51
8,000 240 37 47 79-1174SAA1 23 24,000 240 37 47 79-1184SAA1 63
9,000 240 44 54 79-1175SAA1 24 27,000 240 44 54 79-1185SAA1 69
10,000 240 49 59 79-1176SAA1 25 30,000 240 49 59 79-1186SAA1 75
12,000 240 58 68 79-1177SAA1 28 36,000 240 58 68 79-1187SAA1 84
6
Dept. for optional three phase.
HORIZ.2 VERT.2 316 STAINLESS SHIP HORIZ.2 VERT.2 316 STAINLESS SHIP
WATTS VOLTS2 WATTS VOLTS2
inches inches STEEL1 WT. lbs. inches inches STEEL1 WT. lbs.
1,000 240 13 15 79-1208SAA1 10 3,000 240 13 15 79-1218SAA3 30
2,000 240 17 19 79-1209SAA1 11 6,000 240 17 37 79-1219SAA3 33
3,000 240 22 25 79-1210SAA1 12 9,000 240 22 37 79-1220SAA3 36
4,000 240 26 25 79-1211SAA1 13 12,000 240 26 37 79-1221SAA3 39
5,000 240 31 37 79-1212SAA1 14 15,000 240 31 37 79-1222SAA3 42
6,000 240 36 50 79-1213SAA1 15 18,000 240 36 50 79-1223SAA3 45
8,000 240 44 50 79-1214SAA1 18 24,000 240 44 50 79-1224SAA3 54
9,000 240 50 50 79-1215SAA1 20 27,000 240 50 50 79-1225SAA3 60
10,000 240 55 50 79-1216SAA1 22 30,000 240 55 50 79-1226SAA3 66
12,000 240 64 50 79-1217SAA1 25 36,000 240 64 50 79-1227SAA3 75
For 304SS heater, change S to F in Price Code Number. Consult Sales Dept. for other choices.
For titanium heater, change S to T in Price Code Number.
For plain steel, change S to P in Price Code Number.
WARNING
ELECTRIC IMMERSION HEATERS WILL IGNITE
MANY PLASTIC TANKS SUCH AS
POLYPROPYLENE AND POLYETHYLENE AND
IGNITION SUBJECT PERSONNEL TO SHOCK HAZARD IF SHOCK
SOURCE NOT PROPERLY INSTALLED AND MAINTAINED. HAZARD
106
ORDERING INFORMATION
Provides digital indication of setpoints
and control point temperatures. PRICE MODEL VOLTS MAX. SHIP/ WT. OPTIONS*
CODE NO. NUMBER AMPS lbs/(Kg.)
Dual setpoints for heat / cool
79-1670 A DQ 302 240 30 19
applications. 79-1670 B DQ 304 480 (8.5)
1 or 3 phase controls with 10 ft. Add -LT to Price Code Number and
79-1671 A DQ 502 240 50 20
FEP sleeved sensor. 79-1671 B DQ 504 480 (9) Model Number for "less transformer".
0-500F temperature range
79-1672 A DQ 752 240 26
(Field selectable 0 - 260oC). 79-1672 B DQ 754 480 75 (12) Transformer must be used at 480 volts.
cULus listed 79-1673 A DQ 902 240 28
90 PII or PIII resettable systems
.25% accuracy (full span). 79-1673 B DQ 904 480 (13)
6
ORDERING INFORMATION
For temperature control of heated PRICE MODEL MAX. SHIP/ WT.
aqueous solutions. CODE NO. NUMBER VOLTSAMPS lbs/(Kg.) OPTIONS*
Single setpoint
79-1534A NR302 240 15
30F to 220F temperature 30
79-1534B NR304 480 (7) Add -LT to Price Code No. and
range. 79-1535A NR502 240 16
50 Model No. for "less transformer".
1 or 3 phase controls with 79-1535B NR504 480 (7.5)
5 ft. FEP sleeved sensor. 79-1536A NR752 240 22 Transformer must be used at 480 volts.
75
cULus listed. 79-1536B NR754 480 (10) Add -H to Price Code No. and Model No.
5F accuracy. 79-1537A NR902 240 24 for high temp. model (150F to 550F)
79-1537B NR904 480 90 (11) PII or PIII resettable systems
79-1538A NR1202 240 120 26 (Consult Sales Dept.)
79-1538B NR1204 480 (12)
79-1539A NR1502 240 32 *Consult Sales Dept. for other choices
FEP is uorinated ethylene 150
propylene uoro polymer. 79-1539B NR1504 480 (14.5)
Formula 1 Formula 3
(A) ________ x (B) _______ x (C) ________ 1,000 = FT2 (A)____________________
(GALLONS) ( T) (STEAM FACT.) (volts x amps x 3.412) FT. OF
= (A) = SURFACE
(C) AREA
(B) _______________ x 100 REQUIRED
(Req'd. tank temp. (all metals) or
FORMULA FOR HOT WATER HEATING MEDIA minus cooling liquid 30 (Teflon)
temp.)
6
STEP 1 Determine gallons in tank. Enter at (A) in Formula 2.
STEP 3 Multiply (A) times (B) times 8.33. Enter answer at (C). For a more in-depth analysis of
STEP 4 Subtract the required tank temperature from the temperature
your specific heat requirements,
of your hot water supply. Enter this figure at (D). provide the following information
STEP 5 Multiply (D) by 100 for all metals or 30 for Teflon and enter
and we will gladly size your heat
answer at (E). exchanger.
STEP 6 Divide (C) by (E) to determine square feet of area required. If Initial temperature________________________________
more time is available, coil surface area may be reduced by
dividing the square foot area by the heat-up time available, Desired temperature______________________________
up to 4 hours maximum.
Tank size: Length _______ Width _______ Height ______
Formula 2 Solution depth __________________________________
(A)_______ x (B)_______ x 8.33 = ____ Type of solution to be heated or cooled _______________
(gallons) (T)
Production load: Lbs./hr. ________ & load temp. _______
___________________________ = (C) = FT2 OF AREA
100 (all metals) (E) REQ'D FOR ONE Agitation (type) _________________________________
HOUR HEAT-UP
or x (D)______________ Rectifiers: Number ______ Voltage _______ Amp ______
30 (Teflon) (Temp. rise required) Covered or uncovered tank _____________________
Insulated tank & tank material ______________________
STEAM PRESSURE FACTORS
Steam pressure at coil hook-up point ________________
Steam Pressure Cooling media _____ Inlet temp. ______ Flow rate _____
5 10 15 20 25 50
Available PSI
Steam Factor Maximum flow rates, performance curves and
.55 .50 .42 .37 .30 .25
for Metal pressure drops are determined at the factory for
Steam Factor optimum design efficiency. Contact us for perfor-
2.75 2.50 2.10 1.85 1.50 __
for Teon mance data.
Consult Sales Dept. for pressures above 50 lb. for metal and 30 lb.
for Teflon.
108
GRID and SERPENTINE COILS
HEAT EXCHANGERS 316 STAINLESS, TITANIUM A-102M
Outlet Riser
Standard
Inlet Rise
tubing on Nipples 12 Risers
1 / centers
12 Standard Standard 36 6
Length 23
(corresponds to
tank Width
depth) (corresponds
to tank Length
depth)
SURFACE
LENGTH PRICE CODE NO. **
Length (corresponds AREA
to tank wall length) in. 316 SS TITANIUM
Sq. ft.
Width 2.75 24 79-1432SA 79-1432TA
3.75 36 79-1432SB 79-1432TB
Where tank space is at a premium, the gridcoil is only 2" thick. The gridcoil permits 4.75 48 79-1432SC 79-1432TC
full flow-through of solution for efficient heat transfer. Every square inch of surface 5.75 60 79-1432SD 79-1432TD
is an active heat transfe r area. Gridcoils can be banked or stacked for greater 7.25 78 79-1432SE 79-1432TE
heat transfer. 8.75 96 79-1432SF 79-1432TF
Standard connections are 1" NPT nipples on 4" centers for serpentine and 5" solutions - as low as 12". The vertical style is ideal for deep, narrow
centers for grids. 1" NPT nipples on variable centers for vertical models. tanks or wells.
Gridcoils are offered in two styles - horizontal and vertical. However, the horizontal Serpentine coils offer lower cost per heating surface area. The design
gridcoil is more commonly specified. Also, gridcoils can be operated in shallow allows them to be installed in tanks with limited space.
6
GRIDCOIL SPECIFICATIONS
SURFACE COIL DIMENSIONS NUMBER PRICE CODE SURFACE COIL DIMENSIONS NUMBER PRICE CODE
AREA (inches) OF NUMBER ,, AREA (inches) OF NUMBER ,,
Sq. ft. WIDTH LENGTH TUBES 316 SS Sq. ft. WIDTH LENGTH TUBES 316 SS
5.6 12-1/2 30 8 79-1442SB 32.0 18-1/2 120 12 79-1443SK
6.7 12-1/2 36 8 79-1442SC 32.5 36-1/2 60 24 79-1446SE
6.8 18-1/2 24 12 79-1443SA 34.5 24-1/2 96 16 79-1444SH
8.4 18-1/2 30 12 79-1443SB 35.2 18-1/2 132 12 79-1443SL
8.8 12-1/2 48 8 79-1442SD 38.0 42-1/2 60 28 79-1447SE
9.4 24-1/2 24 16 79-1444SA 38.3 18-1/2 144 12 79-1443SM
10.0 18-1/2 36 12 79-1443SC 38.7 24-1/2 108 16 79-1444SJ
11.5 24-1/2 30 16 79-1444SB 38.8 36-1/2 72 24 79-1446SF
13.2 18-1/2 48 12 79-1443SD 42.9 24-1/2 120 16 79-1444SK
13.6 24-1/2 36 16 79-1444SC 45.1 36-1/2 84 24 79-1446SG
13.7 12-1/2 72 8 79-1442SF 45.4 42-1/2 72 28 79-1447SF
13.7 36-1/2 24 24 79-1446SA 47.1 24-1/2 132 16 79-1444SL
15.1 12-1/2 84 8 79-1442SG 51.3 24-1/2 144 16 79-1444SM
15.8 42-1/2 24 28 79-1447SA 51.4 36-1/2 96 24 79-1446SH
16.3 18-1/2 60 12 79-1443SE 52.8 42-1/2 84 28 79-1447SG
16.8 36-1/2 30 24 79-1446SB 57.7 36-1/2 108 24 79-1446SJ
17.2 12-1/2 96 8 79-1442SH 60.2 42-1/2 96 28 79-1447SH
17.8 24-1/2 48 16 79-1444SD 64.0 36-1/2 20 24 79-1446SK
19.2 12-1/2 108 8 79-1442SJ 67.6 42-1/2 108 28 79-1447SJ
19.5 18-1/2 72 12 79-1443SF 70.3 36-1/2 132 24 79-1446SL
19.5 42-1/2 30 28 79-1447SB 75.0 42-1/2 120 28 79-1447SK
20.0 36-1/2 36 24 79-1446SC 76.6 36-1/2 144 24 79-1446SM
22.0 24-1/2 60 16 79-1444SE 82.4 42-1/2 132 28 79-1447SL
22.6 18-1/2 84 12 79-1443SG 89.8 42-1/2 144 28 79-1447SM
23.2 42-1/2 36 28 79-1447SC
23.4 12-1/2 132 8 79-1442SL
25.7 18-1/2 96 12 79-1443SH For titanium grid coil change 'S' to 'T' in price code no.
26.1 24-1/2 72 16 79-1444SF
26.3 36-1/2 48 24 79-1446SD
Add 'V' to end of price code no. for vertical style.
28.9 18-1/2 108 12 79-1443SJ Add 'H' to end of price code for horizontal style.
30.3 24-1/2 84 16 79-1444SG Add 'S' to end of price code number for steam.
30.6 42-1/2 48 28 79-1447SD
Add 'W' to end of price code number for water
109
STATE-OF-THE-ART IN HEAT
Unmatched for operating performance, installation ease and
quality construction, tube coils are produced from high grade
FEP with PTFE guard construction.
Compact tube coil exchangers maximize heating/cooling
efficiency through a design that not only creates extremely
high surface area, but also ensures outstanding flow-through
circulation of the process bath by creating uniform spacing be-
tween the tubing. No other heat exchanger is faster or cheaper
to install/service thanks to a unique design that incorporates
a manifold into the heat exchanger package.
Only the highest quality components and craftsmanship go
into the manufacture of these tube coils . . . so that you can
expect outstanding performance and dependability over a
long service life.
6
ACIDS AND ALKALIES
SIZES FROM 2.25 FT.2 OF EXCHANGE AREA TO
46.5 FT.2
TO ORDER - Select Price Code Number OTHER SIZES AVAILABLE
1/4 TUBE COIL - Rectangular
SURFACE
CONNECTIONS PRICE CODE CUSTOM COIL CAPABILITIES
AREA SIZE in
in. NUMBER We offer many standard model heat exchangers in a
sq. ft.
2.25 " FNPT 11 x 11 x 1 79-1478X wide range of materials such as stainless steel, titanium
4.5 " FNPT 11 x 11 x 2 79-1479X and FEP. Custom configurations, high density exchange
4.5 " FNPT 15 x 15 x 1 79-1480X areas, special fittings on connections, and consideration
9.25 " FNPT 15 x 15 x 2 79-1481X for heating and/or cooling media (as in using a coil for an
evaporator for a refrigeration system) are just a few.
Consult Sales Dept.
1/2 TUBE COIL - Round
SURFACE CONNECTIONS PRICE CODE PRICE CODE MAINTENANCE
AREA in. SIZE in. NUMBER Due to the well known anti-stick properties of FEP, very
sq. ft. little maintenance is required. However, when excessive
6 1" FNPT 17 x 17 x 2 79-1482X build-up does occur, either chemically clean or pressure
12 1" FNPT 17 x 17 x 3 79-1483X spray to clean.
18 1" FNPT 17 x 17 x 4 79-1484X
24 1" FNPT 17 x 17 x 5 79-1485X DO NOT ATTEMPT TO CLEAN BY SCRAPING.
11.5 1" FNPT 23 x 23 x2 79-1486X Manifold fittings may require slight re-tightening after the
23 1" FNPT 23 x 23 x 3 79-1487X first 24 hours of use due to the cold flow properties of FEP.
34.5 1" FNPT 23 x 23 x 4 79-1488X However, once re-tightened, no further tightening should
46.5 1" FNPT 23 x 23 x 5 79-1489X be required.
PLATING, PROCESSING 110
RECTANGULAR TANKS
DIMENSIONS TANK ONLY COVER ONLY DIMENSIONS TANK ONLY COVER ONLY
CAPACITY (Inches) PRICE PRICE CAPACITY (Inches) PRICE PRICE
(Gallons) L xW x D CODE NO. CODE NO. (Gallons) L xW x D CODE NO. CODE NO.
7 12 x 12 x 12 88-0600 88-0606 62 20 x 36 x 20 88-0604 88-0607
11 12 x 12 x 18 88-1551 88-0606 75 24 x 24 x 30 88-3071 88-3315
14 12 x 18 x 15 88-1552 88-3311 90 24 x 36 x 24 88-0610 88-0611
15 12 x 24 x 12 88-3065 88-3310 115 30 x 30 x 30 88-3072 88-3316
18 12 x 18 x 18 88-3066 88-3311 150 24 x 48 x 30 88-3073 88-3317
25 18 x 18 x 18 88-3067 88-3312 230 40 x 45 x 30 88-3074 88-3318
30 12 x 24 x 24 88-3068 88-3310 390 42 x 66 x 33 88-3301 88-3319
7
7
MATERIAL 5/8" x 1/2" 5/8" x 3/4" 3/4" x 3/4" 3/4" x 1" 1" x 1"
DESCRIPTION (molded) PRICE CODE NUMBERS
STRAIGHT / CPVC
W/"O"-RING 33-0713 33-0714 33-0759
& EPDM
ELBOW / CPVC
W/"O"- RING 33-0788 33-0790 33-0758
& EPDM
112
CLAMPS Stainless steel 22-0502 22-0502 22-0505 22-0505 22-0503 22-0503 22-0504
STRAINERS
PP w/hose adapter 99-0166 99-1160
7
BULKHEAD TANK 33-0690 33-0691 33-0692 33-0693 33-0694 33-0695 33-0696
CONNECTION PP
BALL VALVE PP, threaded 33-0560 33-0561 33-0609
w/EPDM "O"-ring
FOOT VALVE PVC, threaded 33-0541 33-0542 33-0543 33-0544 33-0545 33-0546 33-05477
with strainer
VERTICAL CHECK PVC, threaded 33-0593 33-0594 33-0595 33-0596 33-0597 33-0598 33-0599
VALVE
Registered Trademarks: Teflon - DuPont; Viton - DuPont Dow Elastomers; Halar - Ausimont.
114
MALE
33-1334 33-1287 33-1352 33-1353 33-1497 33-1581
THREADS
MALE ADAPTER
STREET ELBOWS
POLYPROPYLENE
NPT 64-0753 40 64-0752 40 64-0756 40
BSP 64-1366 40 64-1367 40 64-1368 40
HOSE KITS 115
A-215B
7
22-0434 22-0433 (1 ea.)33-1284/33-1329
M1x1 S (PP, PVC) (2) 22-0503 99-0743 99-1611
10 ft., 1-1/2" VN 10 ft., 1-1/4" VN (1 ea.)33-2276/33-2275
F1x1
22-0528 22-0527 (1 ea.)33-1469/33-1329
HK1x1 S (CPVC) (2) 22-0503 99-0743 99-1612
10 ft., 1-1/2" VW 10 ft., 1-1/4" VW (1 ea.)33-2276/33-2275
22-0434 22-0433 (1 ea.)33-1469/33-1329
HK1x1 S (PP, PVC) (2) 22-0503 99-0743 99-1613
10 ft., 1-1/2" VN 10 ft., 1-1/4" VN (1 ea.)33-2276/33-2275
S (CPVC, 22-0529 22-0527 (1) 22-0503 (1 ea.)33-1496/33-1506
G2x2 99-0744 99-1614
PVC, PP) 10 ft., 2" VW 10 ft., 1-1/4" VW (1) 22-0504 (1 ea.)33-2276/33-2275
DIMENSIONS FORCE TO OPEN PRICE CODE WITH HOSE FOR HOSE PRICE CODE
FROM CLOSED NUMBER CLAMP SIZE I.D. NUMBER
Small - 4.5" 12 lbs. 99-0190 Small - 4.5" 1/2" to 1" 99-0190A
Large - 7.0" 22 lbs. 99-0191 Large - 7.0" 1-1/4" to 2" 99-0191A
7
Scores of applications:
Walkways around machinery
Assembly lines / Entryways
Showers / Freezers / Work benches
Processing areas / Livestock pens
Marine installations / Truck beds
SKIMMER ASSEMBLY
To remove oating oil & particulates from cleaners, plating baths and other two-phase liquids.
AUXILIARY MOUNTING
Sk i m m er
Pu m p Filter
7
BALLS, SOLID POLYPROPYLENE
"FLOATING SOLUTION BLANKET" - for all processing chemicals
SAVE ENERGY - REDUCE POLLUTION
Pump selection
Pump sizing is largely determining the
desired pressure and ow rate. Most pumps are
of horizontal design. They are available as di-
rect driven or as magnetic coupled seal-less, in
many ow rate/pressure combinations. Which
8
In order to achieve a desired flow and pressure, the pump In any pumping system, valves should be selected to
selected must provide a TDH at the given flow which must maintain the pump prime and control flow and pressure at
exceed the desired discharge pressure plus friction losses the desired levels. In order to prevent backsiphoning, loss of
resulting from the length of the pipe line, fittings and valves in solution or loss of prime, check valves should be utilized.
the line and any other impediments to flow in the line. Consideration must be given to ensure that the pump will
The inlet and outlet port sizes of the pump selected do not develop adequate pressure to open the check valve at time
necessarily indicate the actual size of either the suction or of start-up. A globe valve, ball valve or plug valve should be
discharge piping. When specific gravities higher than 1.0 are installed on the discharge line directly after the pump dis-
encountered, oversized motors are required. charge nozzle. Gate valves are not recommended to throttle
or regulate flow.
D
FILTER
B
FILTER
C PRESS
F
A G H J
E L
K
A Self-priming centrifugal
B Drum, carboy, transfer, centrifuge or screw, or dispensing type piston
C Peristaltic, gear, diaphragm
D Metering
E End suction, non-flooded, direct drive or magnetic-coupled
F End suction, flooded, direct drive or magnetic-coupled
G Diaphragm
H Vertical cantilevered (no bearings)
J Vertical cantilevered (with bearings)
K Vertical cantilevered (with bearings and suction extension)
L End suction with manual valves and priming tank
8
Please sketch system (note elevations)
Reference E in the above illustration indicates that pump would then require priming or a flooded suc-
the horizontal pump would have to be manually tion. Therefore, use of the very longest pump may
primed at least the first time used, and a foot valve be required under certain conditions, particularly
(check valve) should be used on the suction side when it would be necessary to pump at any given
of the pump to maintain the primed condition when time from any level within the reservoir.
the pump is not operating
If the installation requires constant pumping
The illustration also indicates the employment or pumping upon demand, it is recommended that
of three different length vertical pumps, the short- standby pumps are included in the installation. If
est of which will generally be considered to be the the desired flow rate reaches its peak only occa-
most dependable. The slightly longer pump with a sionally, then it might be possible to use a smaller
suction extension could continue to lift the liquid, pump with the second being energized only when
provided the level is slightly above the suction required. In such an instance, a third pump might
strainer (flooded suction). If the pump was shut off be suggested to make absolutely certain that two
and the liquid level falls below the pump and suction of the three pumps are available at any one time.
strainer, it would lose its suction or prime and the
'NPSH' 120
EXAMPLES
Model HE2x1 with No. 4 impeller will flow 140 GPM@62 ft. TDH. The required NPSH is 17 ft.
EXAMPLE A If a pump is connected by a 2" suction pipe one foot long, to the bottom of a 6 ft. deep tank in Chicago, Illinois
(500 ft. elevation), and the tank contains water at 70F, what is the available NPSH?
8
Since the required NPSH is 17 ft., the pump will perform satisfactorily. (Note, if the pump were "hosed"
over the side of the tank, static suction head would be the same, but friction losses would increase).
EXAMPLE B If a pump is connected by a 2" suction pipe 10 ft. long, with 3 elbows, near the top of a 6 ft. deep tank in
Denver, Colorado (5,000 ft. elevation), and the tank contains water at 170F, what is the available NPSH?
Since the required NPSH is 17 ft. and none is available, the pump will experience a reduction in capacity,
loss of efficiency, noise, vibration and cavitation. Net answer: This is a poor application.
121
Should be considered since it determines the frequency of pump operation. Oversize your sump when pos-
PUMP SIZE sible to keep the pump operating for longer periods, rather than constantly stopping and starting, to avoid
torque vibration and possible misalignment.
Pumps should be specied as short as possible and driven as slowly as possible, since the longer the pump,
LENGTH x SPEED or the faster the RPM, the greater the radial load on the bearing surfaces.
Cantilever shaft, bearing-free pumps are recommended for pumping solutions containing abrasives. How-
ABRASIVE CON- ever, on bearing containing pumps, abrasive conditions may be met if a separate, clean, compatible liquid
DITIONS can be used for ushing to lubricate and cool the bearings. This is especially required when more than one
bearing is used.
Make certain adequate liquid is above the pump's impeller to begin pumping, but low enough to prevent
damage to the motor. If it is necessary to pump to a greater depth than the length of the pump, continue to
FLOAT pump to a level below the intake with a suction extension. However, on bearing containing pumps using a
SETTINGS product ush to cool and lubricate the bearing(s), the pump shut-off must be set above the impeller level to
prevent the pump from continuing to run after the reservoir level has dropped too low to provide the neces-
sary product ush for the bearing(s).
Although factory aligned and inspected, positioning of the pump and motor should be checked initially and
ALIGNMENT after periodic operating intervals to assure that misalignment has not occurred, which would place undue
wear on the bearing or seal ring surfaces.
For standby operation, design for the possibility of pump operating interruptions. Employ two or more pumps
AUXILIARY PUMP for continuous or partial operation. For example, for a 100 GPM requirement, employ two pumps at 100 GPM
each or three at 50 GPM each, keeping one ready for service.
8
Select accessories PVC tank cover
individually to complete
your chemical
collection, treatment
or transfer system.
Basket HDPE tank
strainer
Level control,
float or electron
probe actuated
Sump pump
with suction
extension
TIPS FOR THE PROPER SELECTION OF 122
Located outside the pump housing in the back of the support plate, the seal consists of a station-
SINGLE ary ceramic face and cup in contact with the liquid which also lubricates the face of the carbon and
MECHANICAL bellows which is rotated with the shaft. The seal in this position does not have any metal in contact
SEAL with the liquid since the spring used to maintain contact of the seal surfaces is external.
Consists of two independent seals mounted within a seal chamber which is ushed with an
DOUBLE independent water supply at a ow rate of approximately 2 to 4 gallons per hour minimum and
a pressure slightly higher than the maximum expected operating pressure of the pump. Metal
MECHANICAL
components of a double seal assembly do not contact pumped solution. Also, double seal design
SEAL permits the use of a less exotic inboard seal material, so when replacement is necessary, the
replacement seal is less expensive.
The following applications would require a double mechanical seal to minimize the risk of pump failure
resulting from the use of a single seal pump. In some instances, it is the only method to pump the solution.
ELECTROLESS PLATING SOLUTIONS ABRASIVE and CRYSTAL FORMING SOLUTIONS
The double seal contains the liquid in the pump and prevents The pressurized water ush with double seal pumps prevents the
"plating out" onto the inboard seal faces. It is applicable to room abrasive from adhering to the inboard seal faces. If solutions are
temperature or hot solutions. left in the pump, crystals do not form on seal faces because they
CONCENTRATED CHEMICALS are water ushed. Eliminates seal replacement due to scored faces
Recommended because the water ush on the inboard seal faces from both solutions.
reduces the corrosive effect of the solution. CONTAINING CRITICAL SOLUTIONS
HIGH TEMPERATURES For the above reasons, the possibility of seal failure is minimized.
Water ush cools inboard seal faces and reduces the effect of high However, if seal failure should occur, it will be less frequent and can
temperatures on the seal components and adjacent pump elements. be immediately determined by analyzing the seal discharge uid.
PUMP PROTECTORS
Prevent pump damage due to dry operation of system.
8
Terminal
ACIDS / ALKALIES
Ultrasonic
sensor
SOLVENTS / FOOD PRODUCTS
Controller
w/strobe
OILS / WASTE STREAMS
RF PLATING SOLUTIONS / PAINTS
intrusive
sensor
WATER / D.I. WATER
PHOTOGRAPHIC SOLUTIONS
This system allows you to solve industrial liquid level prob-
lems with a value added all-plastic system. Select a reliable
industrial all-plastic level sensor in four technologies, a
RF RF controller or output option and a mounting system. These
non-intrusive intrusive point level switches will offer high and low alarms, automatic
sensor sensor pump up or pump down (automatic empty or fill operations)
and leak detection.
8
comes with 8 ft. of cable coated in the same material as the sensor.
for water-based, viscous, high purity or very haz- These controllers feature SPDT relays rated for hp. or
ardous liquids, process and storage tanks 10 amp resistive at 230 VAC. Adjustable time delay from
0-60 seconds prevents frequent relay-cycling.
Provides non-contact continuous Choose single sensor controllers for single point/alarm ap-
level measurement. LED display indi- PRICE CODE NO. plications. Two sensor controllers perform automatic fill/empty
cates level in inch or centimeter values. operations. Three sensor controllers perform automatic fill/empty
Internal relay for alarm, auto fill / empty 66-1415 operations and offer a separate relay for level alarm.
operation. SPDT relays rated for hp. or Panel mount controllers can be mounted up to 1000
10 amp resistive at 230 VAC. Mounted above liquid in bracket ft. from sensor. LEDs indicate wet/dry sensor condition and
or tank cover, 2 NPT. Unit is constucted of polypropylene and on/off relay status. Mount controllers on any 35mm DIN rail or
PVDF. It can be used with 66-1416 controller if LED display is screw directly to panel. Cord and plug not included.
desired; otherwise controller is not required for operation. Rail mount controllers have a NPT tting that connects
directly to the sensors threaded end or to the mounting rails
end cap. Polypropylene NEMA 4X housing with conduit t-
VERTICAL BUOYANCY SENSOR ting withstands industrial environments. The unit with strobe is a
standard single point controller with a high intensity strobe light
for any clean, non-coating, mounted on top to call immediate attention to alarm conditions.
non-clogging liquid, high level alarms
Dynamically stabilized floats minimize surface chatter, in-
crease reliability and accuracy. Shrouded
body resists turbulence and process debris. PANEL MOUNTED CONTROLLERS
Reed switch rated 15 VA @ 120 VAC. PP 66-1403 PRICE
NPT. -40 to 194F. For rail mounting only. PVDF 66-1403K SENSORS RELAYS APPLICATION CODE NO.
Use with PLC or with a controller.
1 1 Single point, switch/alarm 66-1400
RF CAPACITANCE SENSOR 2 1 Two-point, auto fill/empty 66-1401
(INTRUSIVE) 3 2 Three-point, auto fill/empty w/alarm 66-1402
for any water based liquids, waste sumps, caustic 3 2 Three-point, LED display * 66-1416
soda, D.I. water, process and storage tanks
RAIL MOUNTED CONTROLLERS
High frequency circuit, factory cali- PP 66-1405
brated for plastic ungrounded tanks with 1 1 Single point, switch/alarm 66-1410
PVDF 66-1405K
conductive and non-conductive liquids. 1 1 Single point, switch/alarm w/strobe 66-1411
Eliminates metal grounding straps and reference rods. Resists
coating and works with a wide range of liquids. Mounts on rail 2 1 Two-point, auto fill/empty 66-1412
or through tank wall. NPT. -40 to 194F * Available w/ultrasonic transmitter only
RF CAPACITANCE SENSOR
8
(NON-INTRUSIVE)
IN-TANK MOUNTING RAIL
for water-based, high purity or very hazardous Make system setup easy with these rail kits and accesso-
liquids, process and storage tanks ries. The rails allow you to position the sensor anywhere along
the length of the rail. Slide sensors up or down to adjust level
Mounted on exterior wall of plastic 66-1406 easily. To change sensor, simply snap sensor out of carrier
or fiberglass tank, this unit senses liquid and snap in a new sensor.
through 1 of non-metallic material. Patented two-point calibration Rails come with adapters to fit 2 NPT tank openings. Or,
ensures accuracy and easy installation. Includes polyethylene mount rail on tank wall using optional mounting bracket. Cut
mounting pad for welding, adhesives, or glassing. NEMA 4X rail sections to form shorter lengths.
polysulfone housing.
TYPICAL INSTALLATION
Terminal head
Rail mounted PRICE
controller DESCRIPTION CODE NO.
2 ft. rail kit. 66-1407
Rail Includes 2 NPT adapter, rail and
Panel mounted 4 ft. rail kit. carrier for one sensor. For additional 66-1408
controller 6 ft. rail kit. carriers, see below. 66-1409
Mounting Sensor Terminal head. Provides terminals for up to four sensors.
bracket and Attaches to top of rail. For use with panel mount controllers. 66-1413
carrier
Rail
Mounting bracket. Use to install a rail to the top of the side 66-1414
wall of an open top tank. 2 NPT.
Sensor carrier kit. 66-1417
HI-LO LIQUID LEVEL 125
8
MODEL 7R NEMA 4 Mechanical alternator with high level alarm circuit 66-0962A
NEMA 7 & 9 Mechanical alternator 66-0963A
NEMA 7 & 9 Mechanical alternator with high level alarm circuit 66-0964A
(Class I, Group C, D & Class II, Group E, F, G)
DUPLEX PUMP
MECHANICAL & MOTOR OPTIONAL (for Models 7, 7R & 9R)
ALTERNATOR
TO ORDER - SPECIFY: (1) AC line voltage to relay (2) Lenght of longest probe (3) pH of solution
The agitation shield should be used to isolate the wire suspended probes from a solution in high velocity,
thus preventing twisting of wire leads, resulting in misleading liquid level sensing. The shield is constructed
of all CPVC material. The length of the shield corresponds to the "C" dimension of the sump pump and
length of probe suspension. Standard length - 24"
36" and longer, refer to chart below. RELAY
ENCLOSURE
FOR LONGER PROBE WIRE, ADD . . . FOR LONGER
TOTAL
LENGTH 2-WIRE SET 3-WIRE SET 4-WIRE SET AGITATION SHIELD, ADD . . .
(INCHES) * PVC
PRICE CODE NUMBERS PRICE CODE NUMBERS INSULATED
36 66-1166A 66-1167A 66-1168A 66-1169A WIRE
48 66-1166B 66-1167B 66-1168B 66-1169B
60 66-1166C 66-1167C 66-1168C 66-1169C
72 66-1166D 66-1167D 66-1168D 66-1169D
84 66-1166E 66-1167E 66-1168E 66-1169E PROBE
96 66-1166F 66-1167F 66-1168F 66-1169F
108 66-1166G 66-1167G 66-1168G 66-1169G
120 66-1166H 66-1167H 66-1168H 66-1169H
132 66-1166J 66-1167J 66-1168J 66-1169J LIQUID CONDUCTIVITY
144 66-1166K 66-1167K 66-1168K 66-1169K PROBE SWITCH
MODEL #6
*This includes the standard 24" length. It is not a separate added length.
MODEL P-10 127
DRY RUN
CAVITATION
DAMAGED IMPELLER
CLOSED INLET VALVE
CLOSED OUTLET VALVE
BLOCKAGES
The P-10 digital motor load monitor uses a unique starter, the P-10 protector will monitor motor underload
and patented method of measuring the torque of a OR overload. In pumping applications, conditions such
pump's drive motor. By monitoring the "normal" load as dry run, cavitation, damaged impeller, closed valves or
level any deviation from this range changes the state of blockages will create an "abnormal" underload condition,
the internal relay activating a red LED alarm light. The which the P-10 will detect and subsequently shut down
output relay will shut down the pump, activate additional the pump and provide communication to users and / or
alarm and / or communicate with other equipment in the processes.
process. Designed for use in conjunction with a motor
TECHNICAL DATA
Dimensions 1.77" W x 3.54" H x 4.53" D (45 mm x 90 mm x 115 mm)
Weight 5.25 oz. (0.15 kg)
Supply voltage 1 x 100-240 ( 10%)
3 x 100-600 ( 10%)
3 x 600-690 ( 10%)
Frequency 50 or 60 Hz
Current input Current transformers only; CTM 010, 025 or 050 (Max. 50 A motor)
8
Start-up delay 1 - 64 s
Response delay 0.05 - 64 s
Relay output 5 A 240 VAC Resistive, 1.5 A 240 VAC Pilot duty / AC 12
Fuse Maximum 10 A
Terminal wire size Use 75C copper (CU) wire only.
0.2 - 4.0 mm2 single core (AWG12)
0.2 - 2.5 mm2 flexible core (AWG14), stripped length 8 mm (0.32")
Terminal tightening torque 5 - 7 in.-lbs. (0.56 - 0.79 Nm)
Repeatability 2.5% FS, 24 H, @ +77 F (+25 C)
Temperature tolerance <0.1% / C
External RESET on term. 5 24 - 48 VDC or 24 - 240 VAC, 50 / 60 Hz
Operating temperature 4F 122F (-20C +50C)
Storage temperature 22F 176F (-30C +80C)
Protection class IP 20
Approved by UL and cUL up to 600 V, CE
AMP RANGE MODEL NO. PRICE CODE NO. Each P-10 pump protector comes complete with
.4 - 10 P-10-10 99-1170 monitor, current transformer and complete installation
10.1 - 25 P-10-25 99-1171 instruction manual.
26 - 50 P-10-50 99-1172 To order, use Price Code No.
DRI-STOP 128
6 24V 99-1116R*
DRI-STOP 2R DSWF-1/4 100
PVDF (Kynar), GPH 115V 99-1152R*
Factory installed PSI
polypropylene, 316SS, 180 82 3" x 2-3/4" x 230V 99-1163R
1/4" FNPT (23 (690
polysulfone, Viton 2-5/8" deep 24V 99-1116RE**
LPH) kPa)
8
PRICE
DESCRIPTION CODE NO.
Includes petcock, pressure gauge and fittings 99-1387
129
DRI-STOP 3C and 3K
(Pressure activated)
8
Registered trademarks: Viton - DuPont Dow Elastomers; Kynar - Atochem
OPTIONAL
INSTALLATION TEE
For convenient installation of DRI-STOP on pump discharge DRI-STOP 3
CYCLE ST4 SPB4 SA4 use with most pumps and filtration systems.
115 .5 1/60 66-2161A 66-1197C 66-1197A For horizontal and vertical pump / motor
230 1.5 1/50-60 66-2161B 66-1197DB 66-1197BB
115 1 1/60 66-2162A 66-1198C 66-1198A
assemblies, the starters are neither mount-
230 2 1/50-60 66-2162B 66-1198DB 66-1198BB ed nor wired unless specified and ordered.
115 1.5 1/60 66-1110A 66-1111C 66-1111A (See OPTIONAL).
230 3 1/50-60 66-1110B 66-1111DB 66-1111BB
200 - 230 .5 66-2163A Starters for filtration systems should
3/50-60
380 - 460 1 66-2163B
be ordered as options from respective
200 - 230 1.5 66-2165A 66-2164CB 66-2164AB
380 - 460 3
3/50-60
66-2165B 66-2164DB 66-2164BB bulletins.
200 - 230 3 66-2166A 66-1160CB 66-1160AB
380 - 460 5 3/50-60 66-2166B 66-1160DB 66-1160BB
575 - 600 7.5 66-2166C 66-2167CB 66-2167AB OPTIONAL
200 - 230 5 66-1112CB 66-1112AB
380 - 460 7.5 3/50-60 66-2168CB 66-2168AB
Starter wired to motor with 6 foot (1.8m)
575 - 600 10 66-2168DB 66-2168BB
380 - 460 10 66-1112DB 66-1112BB PVC conduit, connectors and lead wire.
3/50-60
575 - 600 15 66-2169CB 66-2169AB
200 - 230 7.5 66-2170BB 66-2170AB PRICE CODE NO. 66-1170
3/50-60
380 - 460 15 66-1113EB 66-1113BB
200 - 230 10 66-1113DB 66-1113AB
3/50-60
380 - 460 20 66-1114EB 66-1114BB
230 15 3/50-60 66-1114DB 66-1114AB
PUMP 131
MODEL PC 1 & 2
Unique design for mounting to all horizontal pumps
For pumps with 1"
or 2" inlet. Includes Less chance of cavitation
basket strainer.
Four sizes available to handle lifts to 6 ft. (1.8m)
TO ORDER, use Price Code Number. Order BSP connections, pipe, ttings and suction strainers separately.
8
PVC, Noryl & PP (228x228x304)
PC 2 x 2 * 99-1159 2
w/EPDM gasket 2"MNPT x 2" FNPT
100 (379) 2 (.6) w/5" threaded cap
Ryton, CPVC & PP
PC 2 x 2 RCV * 99-1159 R2
w/Viton gasket
PVC w/EPDM 3" FNPT x 2" MNPT 14 Dia. X 36 H 99-0308
PC 3 x 2 180 (681) 3456 (.05 m ) 3
3 (.91)
gasket w/ 1" NPT plug (355 D. x 914 H)
1
To order Viton gasket, add suffix V to Model and Price Code Number. * Not for use with 2" suction pumps.
2
Based on water (1.0 SG) at 68 F (20 C). Suction lift is approximate Removable polypropylene basket strainer.
and determined by air volume in suction piping.
The rugged Series E sump pump is a tough, all A unique characteristic of the Series E pump is its
machined pump designed for years of trouble-free ability to perform on continuous duty as a level control
operation. This pump features a cantilevered, sleeved when an optional suction extension pipe is installed.
stainless steel shaft which eliminates bearings and seals, With the motor energized, the pump will self-prime when
resulting in a pump that can run dry without damage. A liquid is above impeller level. The solution level will then
vapor seal between the rotating shaft and the support be pumped down to the end of the suction extension,
column protects the motor. The compound impeller pre- the pump will lose prime, then reprime when liquid again
vents liquid from rising in the column, even at maximum reaches the impeller.
TDH, while the semi-enclosed bottom impeller provides Discharge pipe assembly, suction extension and
9
efficient flow performance at low horsepower. suction strainer are available options.
DIMENSIONS
TYPICAL
A B C D E F G H J K L M APPLICATIONS
in 4 5-7/8 11-7/8 1/2 2-3/4 2-1/4 2-3/8 3/4 6-1/4 8-3/4 3-1/8 1-7/8
mm 102 149 302 13 70 57 60 19 159 222 79 48
Shipping weight 10 Lbs. (4.54 kg.)
* For EPDM, change V to L in Model and drop A suffix from Price Code No.
OPTIONAL
DESCRIPTION
ADD SUFFIX
TO MODEL MATERIAL
Polyethylene
PRICE
CODE NO.
33-6058
MIXING,
AGITATING
OR TRANSFER
SKIMMING 9
Suction strainer assembly -ST PUMPING
PVDF & ECTFE 45-0251
PP 45-0274
Suction extension, 18 (457mm) -SX CPVC 45-0208 Read: Tips for the successful
PVDF 45-0230 operation of sump pumps.
PP 45-0270 See bulletin TP-113
Discharge pipe assembly -DPA CPVC 45-0225
PVDF 45-0228
SERIES 'EO' 134
FUME SCRUBBING PCB WET PROCESSING OUT-OF-TANK PUMPING SUMP DRAINING and
and FILTRATION WASTE TREATMENT
135
LEGEND: HP FLOW
DIMENSIONS (In.)
" NPT
" NPT
9
PUMP MODEL MATERIAL A B C D E
CPVC 13-3/16 2-5/16 6
PP 13-3/16 2-5/16 6-3/8
EO1 PVDF 13-3/16 2-5/16 5-3/8
.33 HP 5-7/8 8-1/2
.75 HP 7-1/8 9-5/8
CPVC 13-1/4 2-5/16 7-1/4
PP 13-1/4 2-5/16 7
EO1 PVDF 13-1/4 2-5/16 7
1 HP 7-1/4 10-5/8
1.5 HP 7-1/4 10-5/8
136
SERIES 'EO' Ordering information P-312F
TABLE I Select ow curve and material. Use Price Code No. to order.
OPTIONAL EQUIPMENT
The Series 'EH' Sump Pump features a cantilevered, A unique characteristic of all Series 'EH' pumps is their
sleeved, stainless steel shaft with vapor seal between the ability to lift solution with an optional suction extension
rotating shaft and the support column to further protect pipe installed. With the motor energized, the pump will
the motor.The cantilevered shaft eliminates bearings and self-prime when liquid is at impeller level. The solution
conventional pump seals, resulting in a pump that can level will then be pumped down to the end of the suction
run dry without damage. A compound impeller prevents extension to a maximum depth of 9 ft. (2.7m). The pump
liquid from rising in the column, even at maximum TDH, will lose prime, then automatically re-prime when liquid
while the fully-enclosed bottom impeller provides high
hydraulic efficiency at low horsepower.
again reaches the impeller.*
9
* Read: "Tips for the successful operation of sump pumps", Technical Bulletin TP-113.
138
3450 RPM @ 60 Hz
(2850 @ 50 Hz)
A 12
(305)
OPTIONAL 6
DISCHARGE (152)
PIPE ASSEMBLY
33/4 6
(95) B
1 (25) (152)
15 23/4
(381) (70)
7-5/8
(194)
9
11/2 MNPT
2-5/8 (67)
2 DIA. DISCHARGE PIPE
2 FNPT 4
(102) HOLE
SUCTION 1-3/8 (OPTIONAL)
OPTIONAL
(35)
53/4 1-7/8
STRAINER (146) (48)
BOTTOM VIEW
The standard 12" x 15" (305 x 381 mm) mounting plate for CPVC and
polypropylene pumps is shown. PVDF pumps have an 11" x 11"
(298 x 298 mm) mounting plate.
* 15-3/8" and 18" dimensions are for the LX models.
139
Pump models are constructed of CPVC, PPP poly- plate. Assembly offers non-metallic solution contact.
propylene or PVDF with sleeved stainless steel shaft. Chemical duty motors are 1 or 3 phase, TEFC, 50 or
Mounting plate is 1" (25mm) thick and includes PTFE 60 Hz, 3450 or 2850 or 1725 or 1450 RPM, NEMA "C"
vapor seal. Standard "O"-rings are EPDM (ethylene face, painted with two - par t epoxy enamel. May be
propylene) on CPVC pump and Viton on polypropyl- used with up to a 9 ft. (2.7m) suction extension under
ene and PVDF pumps. Impeller is fully enclosed for certain conditions. The pump discharge orientation can
maximum efficiency, compound design with pressure be relocated in increments of 60.
For standard CPVC, PP and PVDF pump-motor combination, select model from TABLE I.
For other pump-motor combinations, select from components in TABLE II.
TABLE I
Select ow curve number providing the desired performance. Then match to Model Numbers listed below.
Motor HP is non-overloading at full capacity.
60 Hz MODELS
FLOW MODEL NUMBER PRICE MODEL NUMBERS PRICE MODEL NUMBER PRICE
CURVE CODE CODE CODE
NO. CPVC NO. Polypropylene NO. PVDF NO.
1 EH 11/2-1SC-D1.5 45-0112 EHP 11/2-1SC-D1.5 45-0612 EHK 11/2-1SC-D1.5 45-0712
2 EH 11/2-2SC-D2.0 45-0123 EHP 11/2-2SC-D2.0 45-0623 EHK 11/2-2SC-D2.0 45-0723
3 EH 11/2-3SC-D3.0 45-0134 EHP 11/2-3SC-D3.0 45-0634 EHK 11/2-3SC-D3.0 45-0734
4 EH 11/2-4SC-D5.0 45-0145 EHP 11/2-4SC-D5.0 45-0645 EHK 11/2-4SC-D5.0 45-0745
5 EH 11/2-5SC-H1.5 45-0159 EHP 11/2-5SC-H1.5 45-0659 EHK 11/2-5SC-H1.5 45-0759
6 EH 11/2-5SC-D7.5 45-0156 EHP 11/2-5SC-D7.5 45-0656 EHK 11/2-5SC-D7.5 45-0756
50 Hz MODELS
FLOW MODEL NUMBER PRICE MODEL NUMBERS PRICE MODEL NUMBER PRICE
CURVE CODE CODE CODE
NO. CPVC NO. Polypropylene NO. PVDF NO.
1
2
EH 11/2-1SC-D1.0 (.75 kW)
EH 11/2-2SC-D1.5 (1.1 kW)
45-0111
45-0122
EHP 11/2-1SC-D1.0 (.75 kW)
EHP 11/2-2SC-D1.5 (1.1 kW)
45-0611
45-0622
EHK 11/2-1SC-D1.0 (.75 kW)
EHK 11/2-2SC-D1.5 (1.1 kW)
45-0711
45-0722
9
3 EH 11/2-3SC-D2.0 (1.5 kW) 45-0133 EHP 11/2-3SC-D2.0 (1.5 kW) 45-0633 EHK 11/2-3SC-D2.0 (1.5 kW) 45-0733
4 EH 11/2-4SC-D3.0 (2.2 kW) 45-0144 EHP 11/2-4SC-D3.0 (2.2 kW) 45-0644 EHK 11/2-4SC-D3.0 (2.2 kW) 45-0744
5 EH 11/2-5SC-H1.5 (1.1 kW) 45-0159 EHP 11/2-5SC-H1.5 (1.1 kW) 45-0659 EHK 11/2-5SC-H1.5 (1.1 kW) 45-0759
6 EH 11/2-5SC-D5.0 (3.7 kW) 45-0155 EHP 11/2-5SC-D5.0 (3.7 kW) 45-0655 EHP 11/2-5SC-D5.0 (3.7 kW) 45-0755
TABLE II
To determine pump model for a specified GPM, TDH, material dotted line. Read required HP at right ordinate and multiply by
and specific gravity, select performance point on curve. Deter- S.G. Select pump, impeller and motor and construct Model
mine required HP by moving vertically to corresponding number and Price Code No.
PUMP IMPELLER
FLOW ADD TO...
MATERIAL MODEL PRICE CODE NO. CURVE NO. MODEL PRICE CODE NO.
CPVC EH 11/2 45-01 1 -1 SC 1
CPVC-18" EHLX 11/2 45-09 2 -2 SC 2
POLYPROPYLENE* EHP 11/2 45-06 3 -3 SC 3
POLYPRO-18" EHPLX 11/2 45-13 4 -4 SC 4
PVDF EHK 11/2 45-07 5 -5 SC 5
PVDF-18" EHKLX 11/2 45-14 6 -5 SC 5
HIGH EFFICIENCY
LOW ENERGY USAGE
Non-metallic solution contact
CPVC construction
to 160F (71oC)
(See a chemical resistance chart)
To 650 U.S. GPM or 175 FT. TDH @ 60 Hz
(2050 l/m or 42m @ 50 Hz)
Can run dry indefinitely, seal-less,
no bearings
Heavy duty PTFE vapor seal
Protects motor bearing and end bell.
In-tank or out-of-tank
Chemical duty motor (7.5 - 20.0 HP)
Sealed oversized bearings. Cast iron end bells with
vapor seal. Corrosion resistant epoxy enamel finish.
Stainless steel nameplate. Service factor 1.15.
The Series 'EHM' Vertical Pump features a cantilevered A vapor seal between the rotating shaft and pump
CPVC sleeved stainless steel shaft with vapor seal between column protects the motor and motor bearings. The
the rotating shaft and the support column to protect the complete pump assembly features non-metallic solution
motor. The cantilevered shaft eliminates bearings and contact.
conventional pump seals, resulting in a pump that can The pump length from the underside of the mount-
run dry without damage. A compound impeller prevents
ing plate to the suction inlet is available as 15" or 18".
liquid from rising in the column while the fully-enclosed The high efficiency impeller provides "pump-down"
bottom impeller provides high hydraulic efficiency at low capabilities to 9 ft. below the inlet using a suction ex-
horsepower. tension. Viton "O"-rings, discharge pipe assembly and
The pump drive shaft is stainless steel and is protect- suction strainer are available as options.
ed by a heavy duty CPVC impeller sleeve assembly.
9
Pump models are constructed of CPVC with CPVC Series 'EHM' pumps offer non-metallic solution contact.
sleeved stainless steel shaft. The mounting plate is PVC The chemical duty motors are 208-230/460V/3/60 @ 3450
and includes a PTFE vapor seal. Standard "O"- rings or 1725 RPM or 190-208/380-415V/3/50 @ 2850 or 1450
are EPDM (ethylene propylene). The compound design RPM, TEFC, NEMA "C" face, painted with two-part epoxy
impeller is fully enclosed for maximum efficiency. enamel. These pumps can be used with up to a 9 ft. (2.7
m) suction extension under certain conditions.
PERFORMANCE
EHM 1
EHM 2
9
TDH
25 120
10
1725 RPM @ 60 Hz
1450 RPM @ 50 Hz H.P
100 60 Hz 50 Hz
20 9
80 20
15
EHM 3 8 10 10
60 15
9 7.5
10
40 10 5
8
5 5 3
20
FT
m
60 Hz 100 200 300 400 500 600 700 GPM
10-1/4DIA
MOTOR DIMENSIONS (260)
MAY VARY
20
8 (508)
(203)
7-3/16
(183) C D
1(25.4)
11/2(38.1) EHM3 4 (102)
4-3/4
15
(121)
23/4 (70) (381)
/4 NPT
3
Suction 3 NPT
15 or 18 * 4 NPT EHM3
(381 or 457)
BOTTOM VIEW
B
A
* 18" dimension is for EHM LX 11/2, EHM3 has 18" x 24" mounting plate
EHM LX2 and EHM3 with centerline discharge
TABLE I For standard CPVC pump-motor combination, select model from TABLE I.
For custom pump-motor combination, select from TABLE II.
Select flow curve number providing the desired performance. Then match to Model Number listed below.
Motor HP is non-overloading at full capacity.
To determine pump model for a specified GPM, TDH, material and specific gravity, select performance
TABLE II point on curve. Determine required HP by moving vertically to corresponding number dotted line.
Read required HP at right ordinate and multiply by S.G. Select pump, impeller and motor and
construct Model and Price Code No.
OPTIONAL
USE SEPARATE
ADD SUFFIX
DESCRIPTION PRICE CODE NO.
9
TO MODEL
EHM 11/2 EHM 2 EHM 3
Discharge pipe assembly
CPVC-15" DPA 45-1201 45-1202
CPVC-18" 45-1208 45-1209 45-1241
Suction strainer ST 45-1203 45-1242
Suction extension, CPVC
12" K12 46-0081 46-0089
24" K24 46-0082 46-0090
36" K36 46-0083 46-0091
SERIES 'TM-V' 145
The Series 'TM-V' vertical pumps take advantage of ings and shaft. With no weep hole, the pump can be
a variety of current technologies. Employing strong easily installed in or out of the tank as long as the
and compact magnets, with massive internal friction impeller is submerged. Specially designed heavy
surfaces, the model 'TM-V' pumps provide long term walled, voluted casings improve pump strength,
reliability in the most demanding services. Sealed chemical resistance, temperature and pressure
column and pump heads reduce the possibility of air capabilities, as well as hydraulic efficiency.
entrapment and minimize corrosion on motor bear-
DIMENSIONS Inches
NEMA
MODEL A B C D E F G
FRAME
TMV6 2.32 11.9 5.625 2.625 7.625 3.58 1.81
56C
TMV10 2.75 12.3 6.125 2.625 6.875 3.94 1.75
TMV15 145TC 3.25 14.125 7.875 3 7 4.875 2.5 NOTE: Motor dimensions may vary.
Series 'TM-V' Polypropylene / EPDM: Polypropylene column, casing, impeller magnet enclosure, carbon fiber
reinforced rear casing. Silica-free ceramic shaft and stationary thrust bushings, carbon filled PTFE rotating sleeve
and thrust bushings, EPDM 'O'-ring, titanium casing fasteners. (Max. temp. 150F, 110 maximum PSI) To order, use
Price Code No. below.
FLOW MAX. FLOW1 MAX. TDH2 MAX. IMPELLER CONNECTIONS PRICE SHIP
HP MODEL NO.
CURVE GPM LPM ft. m S. G.3 DIA. SUCT. x DISCH. CODE NO. WT. (lbs.)
1 34 107 42 8.9 1.5 .75 3.2" 1" FNPT x 3/4" MNPT TMV6-3.2 D.75 51-0130 38
2 67 211 58 12.3 1.4 1.5 3.85" 11/2"FNPT x 1" MNPT TMV10-3.85 D1.5 51-0131 49
3 90 283 64 13.5 1.4 2.0 3.9" 1 /2" FNPT x 11/4" MNPT
1
TMV15-3.9 D2.0 51-0132 65
Series 'TM-V' PVDF / Viton: Same construction as polypropylene except PVDF casing, impeller, internal magnet
9
enclosure, rear casing,Viton 'O'-ring, titanium casing fasteners.. (Max. temperature 150F, 110 maximum PSI)
To order PVDF / Viton pump, add -K to Model No. and Price Code No. above.
Designed for low flow, high head applications, Series VT' non-metallic turbine designs exhibit excellent
'TM-VT' vertical turbine pumps provide an extremely chemical resistance and low wearing characteristics.
reliable and economical alternative to oversized Also, because of their turbine design, Series 'TM-
centrifugal pumps operated near minimum flow with VT' pumps can be throttled to a required duty point
excessive bypass and power requirements. 'TM- without bypassing.
A
DIMENSIONS Inches
Series 'TM-VT' Polypropylene / EPDM: Polypropylene casing, column, impeller magnet enclosure and rear
casing. Silica-free ceramic shaft and stationary bushing. Carbon filled PTFE rotating sleeve and bushing, EPDM
'O'-ring. (Maximum temperature 150F, maximum pressure 110 PSI.) To order, use Price Code No. below.
Series 'TM-VT' PVDF / Viton: Same construction as polypropylene except PVDF casing, impeller magnet en-
closure, rear casing and Viton 'O'-ring. (Maximum temperature 150F, maximum pressure 110 PSI.).
To order PVDF / Viton pump, add -K to Model No. and Price Code No. above
The Series 'HB' Sump Pump features corrosion re- separate source by means of the bleed line. A spiral
sistant construction for deep sumps and chemical ush groove in the rotating bearing ensures a uniform
transfer. A stainless steel shaft sleeved in CPVC ow of liquid across the bearing surface. The bearing
offers unmatched strength and chemical resistance. liner is made of a special uoride-resistant ceramic.
A vapor seal between the rotating shaft and the pump A suction extension can be utilized to pump to depths
column protects the motor and motor bearings. below impeller level. Thus, a shorter pump can
The shaft bearing and liner are positively lubricated be used, reducing shaft length and the number of
with the product being pumped or clean water from a bearings required.
9
Performance Horsepower
B
HORSE- RPM NEMA A B SHIP. WT2
POWER @ 60 Hz FRAME inches mm Inches mm lbs. kg.
A 1.0 1725 103 47
1.5 1725 143TCZ 9-7/8 251 9-5/8 244 102 46
1.5 3450 102 46
2.0 3450 145TCZ 9-7/8 251 9-5/8 244 106 48
2 (51)
3.0 3450 182TCZ 11-7/8 302 10-3/4 273 116 53
5.0 138 63
3450 184TCZ 13-1/4 337 11-1/4 286
7.5 151 68
WATER
9
FLUSH 1
Pump length (C) and mounting plate dimensions are as ordered
LINE 2
Approx. weight of 2 ft. (.6m) pump with square mounting plate. Add 4 lbs.
(2.0 kg.) per foot (.3m) of additional pump length above 2 feet (.6m).
SECOND C1
BEARING
2" FEMALE NPT
SUCTION
8-9/16 (217)
2-3/4 (70)
2-5/8
(67)
4 5-3/4 1" MALE NPT
(102) (146) DISCHARGE
7-1/8
(181) BOTTOM VIEW
151
Standard models are constructed of CPVC with high suitable for 140F (60C) maximum. High temperature
purity chemical resistant graphite or Rulon (glass models to 160F (71C) are available as single
filled PTFE) bearing and silica-free ceramic liner for graphite bearing pumps only. Pump lengths are
fluoride resistance. Includes polyethylene suction available as listed in one foot (.3m) increments only.
strainer. Elastomer "O"-rings are EPDM (ethylene The bleed line provides pressurized water or pumped
propylene) with Viton optional. Impeller is fully solution to the bearings. (Each bearing requires 10
enclosed for maximum efficiency. Pump shaft is 303 PSI.) Standard is external water flush. Product flush
stainless steel sleeved in CPVC, so complete pump may be specified. All models are wet tested before
assembly offers non-metallic solution contact except shipment. Series 'HB' pumps can provide up to 9
for titanium fasteners at each bearing. Hastelloy ft.(2.7m) suction lift under certain conditions.
C276 fasteners are optional. Standard pumps are
For standard 24" - 60" pump / motor combinations, select model from TABLE I.
For other combinations, select components from TABLE II.
TABLE I
Registered Trademarks: Rulon - Dixon; Viton - DuPont Dow Elastomers; Hastelloy - Hayness International.
152
TABLE II
Determine pump-motor model for a specified GPM, TDH, Read required HP at right ordinate and multiply by specific
length, bearing and specific gravity. Select performance gravity. Select pump model components and Price Code
point on curve and size HP from corresponding number Numbers from Table II.
dotted line vertically above or below performance point.
EXAMPLE:
PUMP + IMPELLER + LENGTH + BRG & LINER + MOTOR = PRICE CODE NO.
+ + + + =
OPTIONAL
HP
MOTOR DIMENSIONS
MAY VARY
3" (76)
1" (25)
SHOWN W/OP-
1" (25) TIONAL
MOUNTING
PLATE AND
DISCHARGE
PIPE
ASSEMBLY
OPTIONAL
EXTERNAL
WATER FLUSH
TO BEARINGS
3" FNPT
DISCHARGE
3" FNPT 2" FNPT
SUCTION D DISCHARGE D
11" E C
Dia.1
(280) 12-1/8"
(308) E
11"
(280) 1
13-1/8" (333mm) for B2x6 4" FNPT
SUCTION
B1 B2
BOTTOM VIEWS
6" (152) B1
10" (267) B2
9
Standard models are constructed of CPVC with high with two-part epoxy enamel. Pump shaft is 303 stainless
purity chemical resistant graphite or Rulon (glass filled steel sleeved in CPVC. Complete pump assembly offers
PTFE) bearing and silica-free ceramic liner for fluoride non-metallic solution contact except titanium fasteners
resistance. Includes threaded suction and discharge. Models at each bearing (Hastelloy C 257 optional). Pump lengths
B1 have polyethylene suction strainer, Models B2 have are available in one foot (.3M) increments. Bleed line
CPVC suction strainer. The "O"-rings are EPDM (Viton provides water or pumped solution to bearings. (Each
optional). Models B1 have semi-enclosed impellers, bearing requires 10 PSI.) All models wet-tested before
Models B2 fully-enclosed impellers. Motors are "C" face, shipment. Standard is external water flush. Product flush
1725 RPM, 230-460V/3/50-60, TEFC, chemical duty, painted may be specified, or field converted.
For standard 24" - 60" pump-motor combinations, select model from TABLE I.
For custom pump-motor combination, select components from TABLE II.
TABLE I
Select flow curve number providing the desired performance.
Then match to Model Numbers listed below.
Motor HP is non-overloading at full capacity.
TABLE II Determine pump model for a specified performance point. Read required HP at right ordinate and
GPM, TDH, pump length and bearing. multiply by specific gravity. Select pump model components
Select performance point on curve and size horsepower from and Price Code Number from Table II.
corresponding number dotted line vertically above or below
PUMP - LENGTH (Dimension C)
PUMP MODEL PRICE NO. of ADD TO . . .
CURVE NUMBER CODE NO. BEARINGS MODEL PRICE
1 B1 x 1SCEY 46-1 FT. (M) B1 B2 NUMBER CODE NO.
2 B1 x 2SCEY 46-2 2 .6 1 1 - 24"C 02
3 B1 x 3SCEY 46-3 3 .9 1 1 - 36"C 03
4 B2 x 4SCEY 46-4 4 1.2 1 2 - 48"C 04
5 1.5 2 2 - 60"C 05
5 B2 x 5SCEY 46-5
6 1.8 2 2 - 72"C 06
6 B2 x 6SCEY 46-6 7 2.1 2 3 - 84"C 07
8 2.4 2 3 - 96"C 08
9 2.7 3 3 - 108"C 09
Read:"Tips for the successful operation of 10 3.1 3 3 - 120"C 10
sump pumps". See Technical Bulletin TP-113. 11 3.4 3 3 - 132"C 11
12 3.7 3 3 - 144"C 12
OPTIONAL
Hastelloy C 257 bearing fasteners -HC X pipe assembly, same length as pump-
-5 (2" pipe on B1, 3" on B2)
50 Hz - B2 Models 5
Square- 24" x 24" x 1" thick
-SD 46-0079 46-0107
(610 x 610 x 25.4mm)
Round- 24" diameter x 1" thick
-CD 46-0080 46-0108
(610 diameter x 25.4mm)
Consult Sales Dept. for explosion-proof motors, -K12" (308 mm) 46-0081 46-0089
custom pump stations, motor starters, level controls Suction extension, CPVC pipe,
-K24" (610 mm) 46-0082 46-0090
and Dri-Stop flow switch for bearing protection. threaded both ends
-K36" (915 mm) 46-0083 46-0091
SERIES 'ECI' & 'ESS' 157
ACIDS
WET PROCESSING SOLUTIONS
FUME SCRUBBERS
CLEANING SOLUTIONS
The Series 'ECI' and 'ESS' ver tical pumps The bushing is lubricated by the product being
feature a high efficiency semi-open impeller, cast pumped, thus no external flushing liquid is required.
construction for superior strength and corrosion However, since the bushing is being product flushed,
resistance, and a cantilevered 316 stainless steel shaft these pumps must be used inside the tank. The
guided by a graphite or Rulon bushing. This same optional heavy duty mounting plate uses a clamp
bushing design and unique column assembly allows arrangement which allows it to be positioned anywhere
for reliable operation with columns up to 44". along the length of the pump column. The optional
discharge pipe then fits through the mounting plate
for easy drop-in installation.
9
Pumps are constr ucted of 316 stainless steel Optional mounting plate can be clamped and tightened
throughout for maximum corrosion resistance. Gasket is at any given point on the pump column, which allows the
a synthetic fiber with cast iron, Teflon with 316 SS, shaft pump to be set at the desired depth. Motors are 3450 RPM
vapor seal is Viton. Shaft is available in four lengths to 44". @ 60 Hz or 2850 @ 50 Hz, TEFC or EXP, painted with
Graphite or Rulon shaft bushing provides vibration-free two-part epoxy paint. Single phase TEFC motors include
service and is located directly above the semi-enclosed 8 ft. (2.4m) line cord.
high efficiency impeller, therefore, it is product flushed.
DIMENSIONS
DIMENSIONS Inches
MODEL HP SUC. DISCH. WEIGHT
A NPT (In.) A B C D E F Lbs.(kg.)
3/4 6-1/8 9-1/4 13 59 (27)
ECI1 1 6-1/8 9-3/4 20 63 (28)
ESS1 1-1/2 1-1/4 1 7-1/4 10-1/2 32 3-1/2 6-5/8 69 (31)
2-3/4
2 7-1/4 11-1/8 44 85 (39)
1 6-1/8 9-3/4 13 63 (28)
B 1-1/2 10-1/2 20 80 (36)
7-1/4
ECI1 2 11-1/8 32 3-3/4 7-7/8 85 (38)
7-1/4 3-1/8
ESS1 3 2 1-1/2 12-3/8 44 88 (40)
7-1/4
5 8-1/2 13-5/8 - -
9
4" Max.
5"
immersion
Min.
C
3/16" D
immersion
Optional
mounting
plate E
2"
F
Discharge
1"
Suction BOTTOM VIEW
159
TO ORDER
OPTIONAL EQUIPMENT
9
ADD SUFFIX USE SEPARATE
DESCRIPTION to MODEL NO. PRICE CODE NO.
Mtg. plate (12"x12" w/hole for disch. pipe assy.)
Steel -MP 61-1000
304 stn. steel 61-2000
WASTE TREATMENT
ACID NEUTRALIZATION / PLATING RINSE
PHOTOGRAPHIC & LABORATORY SOLUTIONS
CHEMICAL STORAGE
Pump &
8 ft. motor
line cord Outlet
MNPT E
Inlet
FNPT
Optional
HL alarm Inlet
D
3"
C Pump On
Pump Off
Pumps are constructed of CPVC, mounted on a chemical duty, single phase TEFC, rated continuous duty
thick PVC tank cover (", " or 1", depending on model). at either 50Hz or 60Hz, and are supplied with 8 ft. line
PVC cover plate is bolted down to the tank with 304SS cord with molded plug. Level controls are state-of-the-art
bolts. Pumps are independently mounted to the CPS electronic conductivity type with 316SS probes or float
cover via their own mounting plate. This allows for "drop sensors for non-conductive solutions. The level control
in" ser vice or replacement. Tanks are molded rigid relay is mounted in a watertight (IP54) PVC enclosure
HDPE, eliminating leakage. Tank is provided with 1" or which includes on/off switch with indicating light.
2" NPT inlet fitting installed near top of side. Motors are
EXAMPLE: TANK + PUMP + CONFIGURATION + LEVEL CONTROL = MODEL & PRICE CODE NO.
CPS25- + EO1 + -D + C = CPS25-EO1-DC
CPS230
10
.5 C.5 A D.5 E 18 8
"O"-RING & .75 C.75 B D.75 F 22 10
PUMP1 IMPELLER MECHANICAL SEAL 1.0 C1.0 C D1.0 G 27 12
PRICE CURVE ADD TO CARBON / ADD TO 1.5 C1.5 D D1.5 H 32 14
MODEL MATERIAL CODE NO. NUMBER MODEL & PCN CERAMIC & MODEL PCN 2.0 C2.0 L D2.0 J 37 17
HH1xC CPVC 61-51 1 1 EPDM L(M1) 1 3.0 C3.0 D3.0 K 45 20
HH1xK PVDF 61-52 2 2 VITON V(M2) 2 5.0 See TABLE III. 65 30
3 3
4 4
5 5 1
To order pump only ( without motor), delete motor suffix from Model Number and
Price Code Number.
2
For explosion-proof motors, consult Sales Department.
3
For shipping weight of pump-motor assembly, add 5 lbs. (3 kg.) to motor ship. wt.
A DRI-STOP 3 Pump Protector switch is available to prevent 4
Single phase - 115-208-230V/1/60 or 220-440V/1/50
damage to pump due to dry operation. Consult Bulletin A-105. Three phase - 208-230-460V/3/60 or 380-415V/3/50
10
For 50 Hz, add -50 to Model No. and add 5 to Price Code No.
17 15
(432) (381)
1.5 & 2.0 HP .75 & 1.0 HP 8.3 (211)
2.6 (66) 1.5
(38)
5
(127)
6.2
(157)
3.5
(89)
TABLE II
To determine pump/motor model for a specified GPM, TDH, mechani- cally above or below performance point. Read required horsepower
cal seal and/or specific gravity, select performance point on curve at right ordinate and multiply by specific gravity. Select pump model
and size horsepower from corresponding numbered dotted line verti- components and price code numbers.
EXAMPLE: Typical Model No. 1 x1K 1 V(M2) -D.75 = 47-2111D Price Code No.
PUMP IMPELLER
"O"-RING & MOTOR*
MECHANICAL SEAL (TEFC, 3450 RPM 2)
OPTIONAL
1
For shipping weight of Pump/Motor assembly or-
dered from Table II, add 3 lbs., (1.4 kg.) to motor
weight.
DESCRIPTION PRICE CODE NO. 2
Consult Application Engineering Dept. for
ADD -T TO 50 Hz motors as well as elbows, pipe, gaskets,
TITANIUM SHAFT ADAPTER 44-1930 clamps, motor starters, BSP fittings or adapters
MODEL NO.
LONG-COUPLED KIT MOTOR FOR MOTOR
HP FRAME
LCK6 .75 & 1 56 42-0216 A DRI-STOP Pump Protector switch is available to
LCK7 1.5 & 2 143T & 145T 42-0217 prevent damage to pump due to dry operation.
MOTOR MOUNTING AND ALIGNMENT (for long coupling) 42-0204 Consult Bulletin A-105.
SERIES 'HC' & 'HK' 167
DIMENSIONS
MODEL HK1-1/2 x 1-1/2
MODEL HC1 x 3/4 J
*JJ H
J *HH
*JJ H C G
C
*HH G
F
B F
B
E
D E
A
OPTIONAL " DRAIN
(48-0212) D A
42-0204.
For 56 frame (HC1 x 3/4 pump) - LCK-1 42-0210
For 143T & 145T frame
(HK1-1/2 x1-1/2 pump) - LCK-2 42-0217A
Assembled with motor 42-0204
169
ORDERING INFORMATION
Select ow curve with desired performance. Select CPVC or PVDF. All models have carbon/SF ceramic
TABLE I seal, Viton elastomers, and single phase motor. Motor HP is non-overloading for full ow at 1.2 S.G.
To construct model/price code number for pump with EPDM elastomers, SiC seal, three phase motor or increased
TABLE II horsepower, see chart below. Use price code number to order.
EXAMPLE:
PUMP + IMPELLER + ELASTOMER & MECHANICAL SEAL + MOTOR = PRICE CODE NO.
HK1 x 1K + 3 + V(M8 x M1) + D1.5 = 47-0938 H
SERIES 'HN' 170
RELIABLE CORROSION-RESISTANT
PUMPS FOR:
ACID / AQUEOUS / CAUSTIC /
PLATING / SCRUBBING
WASTES AND WASTE WATER
Non-metallic solution contact
30% glass-filled Noryl
(Refer to a chemical resistance chart)
To 135 U.S. GPM or 88 ft. TDH @ 60 Hz
(425 LPM or 19 M @ 50 Hz)
Single mechanical seal
carbon / silica-free ceramic
EPDM or Viton elastomers
Centrifugal - quiet, vibration-free
Standard NEMA C face 56J TEFC motor
1" x 1" FNPT connections
Back pull-out design, easy assembly
and maintenance
DIMENSIONS
Typical "C" dimensions
DISCHARGE of TEFC motor and wt.
2-7/8 1-1/2 NPT 2-49/64 HP of pump / motor unit.
1 Phase 3 Phase
INLET
1-1/2 10.25" 9.38'
/4
3
NPT 35 lbs. 30 lbs.
7-17/32 11.25" 9.38"
1
44 lbs. 33 lbs.
Here is a pump capable of "total" chemical resistance, assembly eliminate any metal in contact with the
both internally and externally with its non-metallic solution pumped. The unique design of the mechanical
construction of all wetted components, choice of seal seal isolates metal components from solution contact.
assembly and elastomer materials. Engineering grade The double mechanical seal model requires water lubrica-
plastics provide application compatibility with a variety tion of the seal faces and allows the pump to be used for
of chemicals that would be corrosive to other materials solutions containing abrasives, a high salt concentra-
of construction. tion and for electroless plating solutions. The standard
(M8) seal assembly is silicon carbide and designed for
The totally enclosed impeller is molded to close
slurries, abrasive solutions and for solutions which
tolerances which allow this pump to operate at peak
contain fluorides. The M8 seal is the most durable and
horsepower efficiency across a broad range of operational
longest lasting mechanical seal available. Viton or EPDM
flow/head requirements.
elastomers are available on the 'HE' pump.
The external mechanical seal and impeller sleeve
10
Standard models are constructed of CPVC, poly- containing abrasives and for high temperature or other
propylene or PVDF with threaded connections. The mo- critical service. Close coupled motors are NEMA 'JM' or
tor shaft is protected by the impeller sleeve assembly. metric (IEC) standard. The motors designated NEMA
Elastomers are EPDM or Viton. Impellers are enclosed. can operate on 50 or 60 Hz at full rated horsepower.
The mechanical seal is type 21, externally mounted with Consult Application Engineering Department for BSP
stainless steel components not in solution contact. A fittings or adapters.
double mechanical seal is recommended for solutions
8-9/16
A (217)
2-5/8 2-3/4
1-1/2" NPT (67) (70)
5-3/4
(146)
B J
2"
NPT C
7-3/4
(246) METRIC D
G F E
H
DIMENSIONS for NEMA motors are in inches and those for metric motors are in mm. MOTOR
WT.*
MOTOR HP A B C D E F G H J Lbs.
1.5 (& 1 @ 1725 RPM) 16.94 8.63 3.5 5.5 6.75 10.5 4 4.75 9.25 43
N 2 (& 1.5 @ 1725 RPM) 18 8.63 3.5 5.5 6.75 10.5 5 5.75 9.25 44
E 3 19.63 9.63 4.5 7.5 9 11.25 4.5 5.5 10.25 50
M
5 21 9.63 4.5 7.5 9 11.25 5.5 6.5 10.25 65
A
7.5 21 9.63 4.5 7.5 9 11.25 5.5 6.5 10.25 110
10
M MOTOR KW A B C D E F G H J Kg.
E 1.5 (90S frame) 496 212 90 140 170 307 100 125 236 23
T
R 2.2 (90L frame) 521 212 90 140 170 307 125 150 236 25
I
C 3.0 (100 frame) 549 236 100 160 197 314 140 172 246 30
Select performance point on curve, determine required HP by moving vertically from GPM
to corresponding number dotted line. Read the required HP at right ordinate and multiply by S.G.
This is the HP required.
GPM @ 3450 RPM, 60 Hz
LPM @ 2850 RPM, 50 Hz
TABLE I - Standard models with SINGLE silicon carbide mechanical seal and Viton elastomers
FLOW CPVC PRICE PVDF PRICE POLYPROPYLENE** PRICE
CURVE CODE CODE CODE
NO. MODEL NO. NUMBER MODEL NO. NUMBER MODEL NO. NUMBER
1 H2 x 11/2 CE1V(M8) -D1.5 42-0118A H2 x 11/2 KE1V(M8) -D1.5 42-0318A H2 x 11/2 PE1V(M8) -D1.5 42-0418A
2 H2 x 11/2 CE2V(M8) -D2.0 42-0128B H2 x 11/2 KE2V(M8) -D2.0 42-0328B H2 x 11/2 PE2V(M8) -D2.0 42-0428B
3 H2 x 11/2 CE3V(M8) -D3.0 42-0138C H2 x 11/2 KE3V(M8) -D3.0 42-0338C H2 x 11/2 PE3V(M8) -D3.0 42-0438C
4 H2 x 11/2 CE4V(M8) -D5.0 42-0148D H2 x 11/2 KE4V(M8) -D5.0 42-0348D H2 x 11/2 PE4V(M8) -D5.0 42-0448D
5 H2 x 11/2 CE5V(M8) -D7.5 42-0158E H2 x 11/2 KE5V(M8) -D7.5 42-0358E H2 x 11/2 PE5V(M8) -D7.5 42-0458E
6 H2 x 11/2 CE6V(M8) -H1.0 42-0168F H2 x 11/2 KE6V(M8) -H1.0 42-0368F H2 x 11/2 PE6V(M8) -H1.0 42-0468F
TABLE IA - Standard models with DOUBLE silicon carbide mechanical seal and Viton elastomers
FLOW CPVC PRICE PVDF PRICE POLYPROPYLENE** PRICE
CURVE CODE CODE CODE
NO. MODEL NO. NUMBER MODEL NO. NUMBER MODEL NO. NUMBER
10
1 H2 x 11/2 CE1V(M8 x M1) -D1.5 42-0119A H2 x 11/2 KE1V(M8 x M1) -D1.5 42-0319A H2 x 11/2 PE1V(M8 x M1) -D1.5 42-0419A
2 H2 x 11/2 CE2V(M8 x M1) -D2.0 42-0129B H2 x 11/2 KE2V(M8 x M1) -D2.0 42-0329B H2 x 11/2 PE2V(M8 x M1) -D2.0 42-0429B
3 H2 x 11/2 CE3V(M8 x M1) -D3.0 42-0139C H2 x 11/2 KE3V(M8 x M1) -D3.0 42-0339C H2 x 11/2 PE3V(M8 x M1) -D3.0 42-0439C
4 H2 x 11/2 CE4V(M8 x M1) -D5.0 42-0149D H2 x 11/2 KE4V(M8 x M1) -D5.0 42-0349D H2 x 11/2 PE4V(M8 x M1) -D5.0 42-0449D
5 H2 x 1 /2 CE5V(M8 x M1) -D7.5
1
42-0159E H2 x 1 /2 KE5V(M8 x M1) -D7.5
1
42-0359E H2 x 11/2 PE5V(M8 x M1) -D7.5 42-0459E
6 H2 x 11/2 CE6V(M8 x M1) -H1.0 42-0169F H2 x 11/2 KE6V(M8 x M1) -H1.0 42-0369F H2 x 11/2 PE6V(M8 x M1) -H1.0 42-0469F
Notes: Motor HP shown is non-overloading for full flow * 1725 rpm @ 60 Hz, 1450 rpm @ 50 Hz
with 1.1 specific gravity fluids. ** Polypropylene models are glass reinforced
See Table II on page 4 for additional selections. NOTE: S.G. = Specific gravity of liquid pumped.
175
TABLE II
EXAMPLE: PUMP/MOTOR MODEL NUMBER PRICE CODE NO.
H2x1-1/2KE 1_ V(M8xM1) -D1.5 = 42-0319A
OPTIONAL
ANSI DIMENSIONAL
HEAVY DUTY CONSTRUCTION
The Series 'HA' is a heavy-duty, ANSI dimensional The Series 'HA' horizontal pump is available in four
horizontal pump engineered for utmost reliability in sizes with flow rates to 1200 U.S. GPM (3800 LPM),
severe chemical applications. The pump is machined and is available with single or double mechanical
from solid CPVC and utilizes an externally mounted seals and EPDM or Viton elastomers. Larger sized
mechanical seal. The 3x2x6 and 4x3x8 pumps have pumps designed to achieve 2400 U.S. GPM are in
sleeved shafts for non-metallic solution contact development. The standard configuration for these
while the 4x3x10 and 6x4x10 pumps utilize titanium pumps is close coupled, however certain models
or Hastelloy C shafts. This proven design provides are available long-coupled.
excellent resistance to aggressive chemicals as The Series 'HA' pump with its high flow rates, chemi-
well as economical and reliable operation for many cal resistance and durability makes it the perfect
years of service. "workhorse" for chemical processing, transfer and
filter pumping, fume scrubbers and cooling towers
or for waste treatment applications.
10
RECIRCULATE
(100 GPM)
TITAN
(100 GPM)
RECIRCULATION BACKWASH TO
TANK HOLDING TANK
OVERFLOW AHEAD OF pH
TO SEWER ADJUSTMENT
(50 GPM) (100 GPM)
Pumps are machined from solid CPVC. 3x2x6 and 4x3x8 Single or double mechanical seals are available depending
pumps have CPVC sleeved shafts while 4x3x10 and on the application. A double, water flushed mechanical seal
6x4x10 pumps have titanium shafts standard with Hastel- is recommended for solutions containing abrasives, high
loy C shafts optional. Elastomers are Viton or EPDM. All temperatures or other critical service applications.
models have an enclosed impeller, externally mounted
Type 21 mechanical seal with silicon carbide seal faces The standard configuration for Series 'HA' pumps is
and ANSI 150 lb. flange connections. External hardware close coupled, however 3x2x6 and 4x3x8 pumps are
not in solution contact is stainless steel. Motor is painted also available long coupled. Pumps 20 HP and above
with two-part epoxy paint. are mounted on a 36"x15" steel baseplate.
MODEL 3 x 2 x 6 MODEL 4 x 3 x 8
MODEL 4 x 3 x 10 MODEL 6 x 4 x 10
12
11
10
9
60 50
Hz Hz
30 18
12 25 15
20 12
11
10 15 9
10
9 10 6
5 3
0 0
G PM
FLOW Performance
C U RVES
MOTO R H. P.
Horsepower
178
DIMENSIONS
G A
B E
H F
M C
K L J
N
254TC 15.0 119/16(294) 4(102) 81/4(210) 11(279) 9.6(244) 15.5(394) 17.8(452) 12.0(305) 10.0(254) 8.3(211) 4.3(109) 6.3(160)
To order standard pump-motor combination select model from Table I. Standard models include CPVC sleeved or
titanium shaft, single mechanical seal and Viton elastomers.
To determine pump model for a specied GPM, TDH, material and specic gravity, select performance point on curve.
Determine required HP by moving vertically to corresponding number dotted line. Read the required HP at right ordi-
nate and multiply by S.G. Select pump, "O"-ring and seal, and motor to complete Model Number. Add corresponding
number designations together to create Price Code Number.
OPTIONS
10
PRICE LONG COUPLING KITS2
DESCRIPTION
CODE NO. FOR MOTOR PRICE
FOR MODELS
Trimmed impeller to meet FRAME CODE NO.
47-0084
specied ow 143/145T 42-0500
Hastelloy C shaft -HC -HC 3x2x6
182/184T 42-0501
4x3x8
213/215T 42-0502
Motor mounting and alignment
42-0504
(For motors 10 H. P. and smaller)
SERIES HCI & HSS 180
The Series 'HCI' and 'HSS' horizontal pumps feature The Series 'HCI' and 'HSS' pumps feature the
compact close-coupled design. A high efficiency most widely accepted industrial mechanical seal
semi-open impeller allows for less clogging and designated as Type 21. This seal is mounted "in-
quick cleaning. board" and, thus tends to be self-cleaning. The seal
is available as a single seal solution flush or as a
Since the components are cast, there are no welds
double seal which uses external liquid as a flush.
to break. Also, cast construction provides a superior
By adding the double seal, these pumps can bet-
corrosion resistance over similar welded styles.
ter handle abrasives / salts and be protected from
running dry.
10
Pumps are constructed of cast iron or 316 stainless when abrasives are present or for certain other critical
steel for maximum corrosion resistance. Gasket is conditions. The stainless steel shaft adapter protects
a synthetic fiber with cast iron; Teflon with 316SS. the motor shaft and allows the use of standard NEMA
Both the single and double inboard seal assemblies motor. Motors are 3450 RPM @ 60Hz or 2850 RPM @
are available in either EPDM or Viton . Double seal is 50 Hz, TEFC or EXP. Single phase TEFC motors include
recommended for flushing the seal chamber with water 8 ft. (2.4m) line cord.
8
7 9
8
6
7
6
DIMENSIONS
D A E H
F Discharge
Suction
10
J
B C
4-1/16" K
4" 2"
G 4"
L
182
TO ORDER
TABLE II
PUMP IMPELLER
Determine pump-motor model for a speci- PRICE FLOW ADD TO . . .
MODEL CODE NO. CURVE NO. PRICE
fied GPM, TDH, mechanical seal and specific MODEL
HCI1 61-03 CODE NO.
gravity. Select performance point on curve and
size horsepower from corresponding numbered HCI1 62-03 1 1 1
2 2 2
dotted line vertically above or below perfor- HSS1 61-01 3 3 3
mance point. Read required horsepower at HSS1 62-01 4 4 4
5 5 5
right ordinate and multiply by specific gravity.
Select pump model components and Price 6 6 6
Code Numbers from Table II. 7 7 7
8 8 8
9 9 9
For explosion-proof motors (UL and CSA approved for Class I, Group D or Class II,
Group F & G), add X to Model No. and Price Code No. EXP motors are 60 Hz only.
FLOW EPDM / Silicon carbide PRICE Viton / Silicon carbide PRICE PRICE
Kalrez / Silicon carbide
CURVE CODE CODE CODE
NO. NUMBER NUMBER NUMBER
MODEL NO. MODEL NO. MODEL NO.
1 HT x 1L (M8) - D.3 61-0000 F HT x 1V (M8) - D.3 61-0010 F HT x 1K (M8) - D.3 61-0020 F
2 HT x 2L (M8) - D.75 61-0001 G HT x 2V (M8) - D.75 61-0011 G HT x 2K (M8) - D.75 61-0021 G
3 HT1 x 1 3L (M8) - D1.5 61-0002 J HT1 x 1 3V (M8) - D1.5 61-0012 J HT1 x 1 3K (M8) - D1.5 61-0022 J
4 HT2 x 1 4L (M8) - D3.0 61-0003 L HT2 x 1 4V (M8) - D3.0 61-0013 L HT2 x 1 4K (M8) - D3.0 61-0023 L
5 HT2 x 1 5L (M8) - D5.0 61-0004 M HT2 x 1 5V (M8) - D5.0 61-0014 M HT2 x 1 5K (M8) - D5.0 61-0024 M
FLOW EPDM / Silicon carbide PRICE Viton / Silicon carbide PRICE PRICE
Kalrez / Silicon carbide
CURVE CODE CODE CODE
NO. NUMBER NUMBER MODEL NO. NUMBER
MODEL NO. MODEL NO.
1 HT x 1L (M8 x M1) - D.3 61-0005 F HT x 1V (M8 x M1) - D.3 61-0015 F HT x 1K (M8 x M1) - D.3 61-0025 F
2 HT x 2L (M8 x M1) - D.75 61-0006 G HT x 2V (M8 x M1) - D.75 61-0016 G HT x 2K (M8 x M1) - D.75 61-0026 G
3 HT1 x 1 3L (M8 x M1) - D1.5 61-0007 J HT1 x 1 3V (M8 x M1) - D1.5 61-0017 J HT1 x 1 3K (M8 x M1) - D1.5 61-0027 J
4 HT2 x 1 4L (M8 x M1) - D3.0 61-0008 L HT2 x 1 4V (M8 x M1) - D3.0 61-0018 L HT2 x 1 4K (M8 x M1) - D3.0 61-0028 L
5 HT2 x 1 5L (M8 x M1) - D5.0 61-0009 M HT2 x 1 5V (M8 x M1) - D5.0 61-0019 M HT2 x 1 5K (M8 x M1) - D5.0 61-0029 M
MODEL KEY
The Series 'RC' horizontal pump is a compact flush or as a double seal which requires external
close-coupled design. A high efficiency, semi-open liquid to flush. When ordered with a double seal, the
cast iron impeller allows for less clogging and quick pump will better handle abrasives, solutions which
cleaning. The components are cast so there are no tend to crystallize, and dry run operation.
welds to break. In addition, the cast iron construc- Series 'RC' pumps are constructed of cast iron with
tion provides improved corrosion resistance over a synthetic fiber gasket. Standard pumps feature
similar welded styles. EPDM or Viton elastomers with ceramic and carbon
The Series 'RC' pump is available with a choice of seal faces. These pumps use a standard NEMA C
mechanical seals, Type 21 single or double. The face motor. Motors are TEFC, 3450 RPM @ 60 Hz
seal is mounted "in-board" and, thus tends to be or 2850 RPM @ 50 Hz.
self-cleaning. It is available as a single seal solution
DIMENSIONS
TABLE II
PUMP IMPELLER MECHANICAL SEAL TEFC MOTOR (3450/2850)
ADD TO . . . ADD TO . . . SINGLE PHASE1 THREE PHASE1
PRICE FLOW MATERIAL
MODEL MODEL PRICE (SOLUTION CONTACT) MODEL PRICE ADD TO . . . ADD TO . . .
CODE NO. CURVE NO. HP
NUMBER CODE NO. NUMBER CODE NO. MODEL PRICE MODEL PRICE
RC200 61-05 SINGLE MECHANICAL SEAL NUMBER CODE NO. NUMBER CODE NO.
1 1 1
2 2 2 EPDM, carbon, ceramic L(M1) 1 .3 - C.3 A - D.3 F
RC300 62-05
3 3 3 Viton, carbon, ceramic V(M2) 2 .5 - C.5 B - D.5 G
4 4 4 DOUBLE MECHANICAL SEAL .75 - C.75 C - D.75 H
1 - C1.0 D - D1.0 J
EPDM, carbon, ceramic L(M1XM1) 3
5 5 5 1.5 - C1.5 E - D1.5 K
Viton, carbon, ceramic V(M2XM1) 4
6 6 6 2.0 -- -- - D2.0 L
7 7 7 Single phase - 115-208-230V/1/60 or 220-440V/1/50 3.0 -- -- -D3.0 M
Three phase - 208-230-460V/3/60 or 380-415V/3/50 5.0 -- -- - D5.0 N
F.O.B. Northbrook, Illinois
Specifications subject to change without notice. For 50 Hz, add -50 to Model No. and 5 to Price Code No.
SERIES 'A' & 'B' 187
The Series 'A' and 'B' magnetic coupled pumps are Impellers supplied on all standard seal-less pumps
seal-less and leakproof, providing total solution and are suitable for water-like liquids up to 1.2 specific
vapor containment. These pumps feature a shaft and gravity.
bearing free design that allows them to be used for Liquids with a higher specic gravity can be pumped if:
electroless solutions. The impeller magnet assembly 1. The outlet flow is restricted so the impeller
floats in the radial magnetic field set up by the exter- magnet stays synchronized with the drive
nal drive magnet, eliminating the need for a shaft or magnet.
spindle. 2. The restrictions from a filter or other source of
The pump body can be rotated to selected direction discharge head loss are sufficient to keep the
of discharge. Neutralizing fluid will normally flush the impeller and drive magnets synchronized.
interior adequately without need for disassembly. 3. The overall diameter of the impeller is reduced.
Toggle
switch 2-1/8(54)
115V
only
7/8
(22) 3-7/8
5/16 (8) dia. (98)
(2) holes 2-3/4(70)
DIMENSIONS
SERIES 'B' Inches (mm)
3-15/16
(100) 12-3/8
1-5/16 (314)
(33) 2-1/4
(57)
6-1/4
(159)
2-5/8
(67)
9/32 slot
(4) places 3-15/16
3-1/2 1-11/16 (100)
(89) (43)
Single phase TEFC motors include 8 ft. (2.4M) of 3-wire cord and plug. (Toggle switch & plug omitted on 50Hz 'A' pump; plug omitted on 50 Hz
'B' pump.)
1
To change "O"-ring from ethylene propylene to Viton, add V to Model Number and Price Code Number.
2
For 'A' pump, to change hose connections to pipe thread 5/8" dia. to 3/8" MNPT add Price Code Number 44-0886.
For 'B' pump, to change hose connections to pipe thread 3/4" dia. to 1/2" MNPT add Price Code Number 44-0887.
11
SERIES 'X' Magnetic Coupled Pumps are the lat- Standard 'X' models have strong magnets and pow-
est in magnetic coupled pump technology. Tested erful, highly efficient continuous duty motors which
and proven design features provide a pump that allow them to operate non-overloading and provide
is seal-less and leakproof. Available materials of continuous flow with liquids up to 1.3 specific gravity.
construction and flow capacities from 1 to 25 U.S. Compact and quiet Series 'X' pumps are designed
GPM make these pumps an excellent choice for to provide years of trouble-free operation.
a wide variety of applications from water at ambi- The following information covers standard Series
ent temperatures to harsh chemicals at elevated 'X' models. For other models and magnetic coupled
temperatures. pumps to 250 GPM, consult our Sales Dept. 11
DIMENSIONS (Inches)
MODEL W H L a b c d e f g
X40 3.73 4.53 8.08 1.19 1.97 5.18 2.68 2.17 1.30 1.12
X50 4.72 5.12 9.12 1.58 2.52 6.65 3.94 2.36 1.89 1.22
X100 4.36 5.12 10.31 1.58 2.52 6.65 3.94 2.36 1.89 1.22
X200 6.14 6.50 13.97 2.76 3.94 8.07 4.33 2.59 2.75 1.72
X250 6.14 6.50 14.30 2.76 3.94 8.07 4.33 2.59 2.75 1.72
11
191
SERIES 'X' Ordering information P-511C
* Consult Sales Dept. for operation with solutions having higher specific gravity.
OPTIONAL
DESCRIPTION ADD TO MODEL NO. ADD TO PRICE CODE NO.
OPTIONAL Motor - 230V / 1 / 50-60 -50 5
EDPM elastomers Consult Sales Department
MODEL KEY
Series 'M' Magnetic-Coupled Pumps are seal-less By using rare-earth magnets, this pump provides flow
and "leak-proof", providing total solution and vapor and pressure equal to that of a physically much larger
containment. They are available in two different materi- pump. This powerful coupling allows the pump to oper-
als of construction for a wide range of chemical and ate at full flow with the full size impeller while handling
temperature compatibility. liquids up to 1.6 S.G. @ 30 CPS.
The relationship of the impeller magnet to the liner The balanced magnetic field eliminates loading on
reflects an advanced design which allows extended bearing surfaces, thus providing an extended life span of
operation at dry run or during loss of prime without caus- the bushing compared to that of other magnetic coupled
ing damage to the pump. The impeller head is separate pumps. The fluted bushing provides positive internal
from the impeller magnet hub for field intechangeability. liquid circulation/flush along the shaft spindle. These
The mouth ring design eliminates the need for a front pumps utilize a high-purity silica-free ceramic stub-
thrust washer. shaft which eliminates breakage and is compatible with
fluoride solutions.
11
Standard models are constructed of chemically service factor. Single phase motors are supplied with an 8
coupled, glass- reinforced polypropylene or car- ft. (2.4m) 3-wire cord and plug. Three phase motors are not
bon-reinforced PVDF for suction casing, impeller- supplied with cord or plug.
magnet assembly and liner. The casing "O"-ring is
Viton. The spindle bushing is carbon with a flush
groove for positive lubrication. The spindle, thrust
button and mouth ring are high purity, fluoride re-
sistant ceramic. The "thrust ring" is carbon filled
Teflon.
External fasteners are 304SS. The inlet and
outlet are designed to accommodate an "O"-ring to
provide a leak tight seal at these connections. The
pump casing includes a blind boss for the " NPT
drain (optional). The inlet O.D. on the 1 x 1 model
will accommodate a 150mm I.D. socket flange.
Maximum pump pressure is 65 PSI (4.4 BAR).
Pumps operating at all flow curves are capable
of handling solutions of 1.6 S.G. at 75F (24C) with
maximum 30 CPS. U.S. motors are NEMA 56C face,
, , and 1 HP continuous duty. They are painted
with two part epoxy gray enamel and have a 1.15
DIMENSIONS
J F E
C B G D
SUCTION DIMENSIONS
MODEL MOTOR
& DISCHARGE A B C D E F G H J
1" FNPT NEMA 3.5 2.75 3.0 4.87
" MNPT 56C (89) (70) (76) (124) 1.81 2.06 6.0 3.5 80
1x or 2.8 1.8 3.5 4.4 (46) (52) (152) (89) (203)
1" FBSP METRIC
" MBSP 71 B3/B14 (71) (45) (89) (112)
1" FNPT NEMA 3.5 2.75 3.0 4.87
1" MNPT 56C (89) (70) (76) (124)
or 1.87 2.75 6.69 3.87 90
1 x 1 1" FBSP 3.15 2.0 3.9 4.9 (47) (70) (170) (98) (228)
METRIC
1" MBSP 80 B3/B14 (80) (50) (100) (125)
11
ORDERING INFORMATION
TABLE I Select flow cur ve number providing the Materials in solution contact include Viton, carbon, silica-
desired performance. Then select either poly- free ceramic. See TABLE II for other models.
propylene or PVDF construction. Use Price Code Number
to order.
1
Motor HP shown will handle full flow to the listed S.G.
TABLE II To determine pump model for use with elevated HP ordinate. Multiply by specific gravity to determine the
specific gravity at specified GPM, TDH, required horsepower. Select the pump impeller, magnet
or material, select performance point on curve. Move verti- coupling and motor to construct the model. Use Price Code
cally to the corresponding dotted line, then horizontally to No. to order.
2
For pump only, eliminate letter suffix
MOTOR4
from Price Code No. and motor suffix
TEFC IP54 from Model.
SINGLE PHASE THREE PHASE THREE PHASE SHIP 3
EXP motors are 60 Hz only; Class 1
FRAME ADD TO . . . ADD TO . . . ADD TO . . . WT Group D and Class 2 Groups F & G.
SIZE lbs. 4
Single phase - 115/208-230V/1/60 or
MODEL PRICE MODEL PRICE MODEL PRICE
NO. CODE NO. NO. CODE NO. NO. CODE NO. 190/200-220V/1/50
Three phase - 208-230/460V/3/60 or
T
C.5 1A D.5 1D 35
190/380-415V/3/50
E C.75 1B D.75 1E 40
F 56C
C1.0 1C D1.0 1F 50 For 50 Hz, add -50 to Model No. and
C
C1.5 1N D1.5 1P 55 add 5 to Price Code No.
E3 E.5 1G F.5 1K 34
X 56C E.75 1H F.75 1L 45
P E1.0 1J F1.0 1M 45
M DM.37 2G 19
E 71B3/B14
T DM.55 2H 19
R
I 80B3/B14 DM.75 3J 28
C
11
SERIES 'D' 195
Corrosion resistant
Polypropylene - PVDF - Ryton
316 stainless steel
(See Chemical Resistance Chart)
Centrifugal quiet, vibration-free
Flows to 53 U.S. GPM or 58 FT. TDH @ 60 Hz
(167 LPM or 12m @ 50 Hz)
Maximum liquid temperature
SELF-PRIMING MODEL 1 x 1
Polypropylene and Ryton: 150oF (65oC)
[To 190oF (88oC) in non-aggressive liquids]
PVDF: 220oF (104oC)
316 stainless steel: 250oF (121oC)
Rugged construction
Designed for continuous duty
Horizontal or vertical discharge
Severe duty motor
All motors carry 1.15 service factor at 50 and 60 Hz
Single phase motors have automatic thermal
overload protection
MODEL 1 x 1
SERIES 'D' Magnetic Coupled Pumps are seal-less, flow and pressure utilizing the available strength of the
providing for maintenance-free and "leak-proof" opera- synchronized magnets.
tion. The magnetic coupling acts as a clutch to provide
The standard diameter impeller is suitable for water-
overload protection. The broad range of construction
like liquids to 1.1 specific gravity. Liquids having a higher
materials allows for a variety of applications and service
specific gravity can be pumped if the overall diameter
with most corrosive solutions.
of the impeller is reduced, the outlet flow is restricted,
The impeller magnet assembly floats in the radial or the restrictions from a filter or other head loss is suf-
magnetic field set up by the motor driven external drive ficient to keep the impeller magnet in synchronization.
magnet. The impeller is designed to deliver the maximum
11
Pump materials of construction are as specified, all of proportionately reduced. Refer to impeller trim chart, specify
which include a fluoride resistant ceramic spindle and thrust impeller diameter and add Price Code No. 48-0200.
washer. Casing 'O' ring is Viton and external fasteners are Motors are chemical service rated continuous duty, TEFC
stainless steel. Standard impeller is designed to pump solu- or explosion proof, painted two-part epoxy gray paint. An
tions having a specific gravity up to 1.1. (See flow curves.) For eight foot (2.4m) three-wire cord and plug are supplied on all
solutions having a higher specific gravity, up to 1.8 maximum, TEFC single phase motors. Three phase and explosion-proof
a trimmed impeller is required. Flow rate and TDH will be motors are supplied without cord or plug.
TDH
60
12 NPSH R
5
HP
60Hz 50Hz
40 4
8 1
1.5 3
20 NPSH Required 1 2
4 0.5
0.5 1
m FT 0 FT
60Hz 5 15 25 35 GPM
CONSTRUCTION MATERIALS
PORT SIZES - 1" F x 3/4" M (NPT)
MAX. MAX. INLET
MODEL SUCTION IMPELLER BUSHING3 LINER TEMP PRESSURE
CASING o
F (oC) PSI (BAR)
7-3/8" 13-3/4"
MRGR 1 Ryton Polypro Ryton Ryton 150 (65) 50 (3.5)
MKGC 2 PVDF PVDF Carbon PVDF 220 (104) 1-7/8"
2-1/16"
1 3
Glass
lled casing, liner, and impeller Ryton bushings are a blend of
2
Carbon ber lled PVDF Ryton, PTFE, and carbon 3-1/2"
IMPELLER TRIM CHART 8"
CLASS I GROUP D
w/TEFC MOTOR w/EXP. MOTOR CLASS II GROUP F & G
MODEL ADD TO SHIPPING ADD TO SHIPPING
NUMBER PRICE PRICE MOTOR VOLTAGE
MOD. NO. WEIGHT MOD. NO. WEIGHT
CODE NO. CODE NO.
(HP) Lbs (kg) (HP) Lbs (kg)
1 x 3/4 MRGR 44-4101 44-4301A 4
11
HP
60Hz 50Hz 8-1/2" 18"
8 40 4
1 1-3/4"
2-3/4"
1.5
4-1/2"
IMPELLER TRIM CHART 11"
3-1/8'
7-1/2" 1-7/16" 4-1/2"
1.5 to 21-25/32"
SPECIFIC 1.0 to 1.1 to 1.3 to 1.7 to 1.9 to Drain
GRAVITY 1.1 1.3 1.5 1.7 1.9 2.0
IMPELLER 1
3-3/4 3-3/8 Glass lled casing, impeller and liner
DIAMETER 3-5/8 3-1/2 3-1/4 3-1/8
std. 2
Carbon ber lled PVDF
60 Hz
3
50 Hz 95.2mm (3-3/4 in) std. 88.9 mm (3-1/2 in.) Ryton bushings are a blend of Ryton, PTFE, and carbon
SELF-PRIMIMG MODELS 4
1-1/2 x 1 SMPGR 44-3350 47 (21) -E.75 44-3352 5 54 (24) 115/190-230/1/50-60
-C.75
1-1/2 x 1 SMKGC 44-3351 47 (21) 44-3353 5 54 (24)
1-1/2 x 1 SMPGR 44-3350C 37 (17) 44-3352C 44 (20)
-D.75 -F.75 190-230/380-415-460/3/50-60
1-1/2 x 1 SMKGC 44-3351C 37 (17) 44-3353C 44 (20)
ADD TO
OPTIONAL EXAMPLE
4 PRICE CODE NO.
Maximum suction lift 10 feet -
Chemic (PTFE & mica) bushing 6 change R to K in Model No. MPGK -K
11
5
60 Hz only Carbon bushing - change R to C in Model No. MPGC -L
6 - MPSGR
This is a replacement for bushings Stainless steel liner add S to Model No. -M
formerly referred to as Chemloy Stainless steel spindle & thrust washer - change G to S in Model No. MSSR -N
SERIES 'F' 198
WASTES / ACIDS
CHEMICALS / PLATING
PHOTOGRAPHIC ETCHING
Made in U. S. A.
Series 'F' Magnetic-Coupled Pumps are seal-less and life span of the bushing compared to that of many standard
"leak-proof" providing total solution containment. Available magnetic coupled pumps. This same "balancing" gives the
in two different materials of construction for a wide range of pump its ability to run dry for 10 minutes, or 30 minutes if wet-
chemical and temperature compatibility. ted, before damage occurs. A fluted bushing provides positive
By using powerful rare-earth magnets, this pump provides internal liquid circulation/flush along the shaft spindle. These
flow and pressure equal to that of a physically much larger pumps utilize a high-purity ceramic stub-shaft which eliminates
pump. This powerful coupling allows the pump to operate with breakage.
the full size impeller at full flow while handling liquids up to 1.8 A unique feature of this pump is its ability to mount to NEMA
S.G. or 50 CPS. and metric frame motors, thus giving motor options of TEFC,
These powerful magnets create a balancing field which elimi- EXP, chemical duty and 575V. The pump is also available long-
nates loading on bearing surfaces, thus providing an extended coupled.
11
Standard models are constructed of chemically coupled, All of the flow curves illustrated are the result of impeller
glass-filled polypropylene or carbon-filled PVDF. "O"-ring is diameter trimming, thus a variety of flow and pressure condi-
Viton on both. Bushing material is high density carbon on both tions can be attained with a single pump and spare impellers.
with flush groove for positive cooling. The casing thrust ring Motors are continuous-duty, painted with two-part grey
and spindle are fluoride-resistant ceramic. Maximum pump epoxy enamel and have a 1.15 service factor. Single phase
pressure: 35 PSI (2.4 BAR) for 1" x 1" model, 60 PSI (4.1 motors are supplied with 8 ft. (2.4 m) of 3-wire cord and plug.
BAR) for 2" x 2" models. 3-phase motors are not supplied with cord.
NPSHr
MODEL 1 x 1 FT. m
30 6
20 4
10 2
0 0
MODEL 2 x 2 NPSHr
FT. m
30 6
20 4
10 2
0 0
11
200
TABLE I Select pump-motor model or flow curve number providing the desired performance.
* For higher specific gravity or reduced flow, refer to HP required. Then refer
to Table II and construct Model and Price Code No. accordingly.
TABLE II
To determine pump - motor for a specific flow, TDH, and/or specific Select pump materials and construct Model and Price Code
gravity, select flow/pressure point on performance curve (solid line). Numbers. Calculate Net Positive Suction Head Available
Required HP is determined by moving vertically to corresponding (NPSHa) for the installation and refer to NPSHr curves on
HP curve (dotted line) and then horizontally to HP scale. Multiply preceding page. NPSHa should be no less than NPSHr to
indicated HP by specific gravity of fluid to be pumped. avoid cavitation or related suction problems.
EXAMPLE:
PUMP + IMPELLER + MOTOR = PRICE CODE NO.
1-1/2 x 1-1/4 MPVGC + 3 + - D1.5 = 51-1036F
2
PUMP 1 IMPELLER MOTOR
PRICE CODE ADD TO... PHASE THREE PHASE
MODEL NO. FLOW PUMP ADD TO...
NUMBER MODEL PRICE ADD TO...
CURVE MODEL
1-1/2 x 1-1/4 MPVGC 51-10 _ _ NO. CODE NO. MODEL PRICE MODEL PRICE
Polypropylene SINGLE NO. (HP) CODE NO. NO. (HP) CODE NO.
3 3 3
-C1.0 6C -D1.0 6D
1-1/2 x 1-1/4 MKVGC 51-20 _ _ 4 4 4
-C1.5 6E -D1.5 6F
PVDF 5 5 5 1 X 1
T -D2.0 7G
2 x 2 MPVGC 51-12 _ _ 6 6 6 E -D3.0 7H
Polypropylene F -D3.0 2H
8 8 8
2 x 2 MKVGC 51-22 _ _ C 2x2
-D5.0 2J
9 9 9
PVDF -D7.5 2K
-D10.0 2Q
-E1.0 6L -F1.0 6M
-F1.5 7N
1 X 1 -F2.0 7P
E -F3.0 7Q
1
For pump only, eliminate motor suffix from Model Number and X -F3.0 2L
suffix letter from Price Code Number. P -F5.0 2M
2x2 -F7.5 2N
2
Single phase - 115-208-230V/1/60 or 110-220V/1/50 -F10.0 2P
Three phase - 208-230-460V/3/60 or 220-380V/3/50. FRAME kW
For 50 Hz, add -50 to Model No. and add 5 to Price Code No. -DM.75 8R
11
M 80-B3/B14 -DM1.1 8S
All motors are 3450/2850 RPM. EXP motors are 60 Hz only; E
T 90-B3/B14 -DM1.5 9T
Class I Group D and Class II Groups F & G. R
Metric motors are IP54. I -DM2.2 4R
C 100-B3/B14 -DM3.2 4S
-DM4.2 4T
201
ALTER ADD TO
DESCRIPTION MODEL NO. PRICE CODE NO.
Teflon bushing Change C to T T
EPDM elastomers Change V to L 1
Flange connections (3" Inlet x 2" outlet)
PP 51-1200
for 2 x 2 models only
PVDF 51-2220
(150# ANSI, welded in place.)
J L
H
M
G Close-Coupled
to TEFC motor
N
F A K E
(dia.) B
C D
1
MOTOR C MOTOR
A B D E F A B C1 D E F
FRAME 1 3 FRAME
M
3 2 9-3/4 8 4-7/8 2-7/16 11/32 (9) E (100) (222) (245) (125) (63) (101)
56 C
(76) (70) (248) (222) (124) (62) SLOT 80-B3/B14
T
N 143 TC 4(102) 2 10 9 5 2 11/32 (9) R
E (100) (125) (293) (140) (70) (10)
145 TC 5(127) (70) (260) (248) (140) (70) DIA. I 90-B3/B14
M C
182 TC 4(115) 3 14 7 3 13/32(10)
A 184 TC 5(140) (89)
(356) (190) (95) DIA. 100-B14
(140) (63) (331) (160) (80) (12)
MODEL G H J K L M N
2
Dimension J is 3.5" (89 mm) with flange option.
1 x 1 In. 1 1 2.88 7.19 2.25 4.75 3.5 3
Dimension K is 11.5" (292 mm) with flange option.
(mm) FNPT MNPT (60) (183) (57) (121) (89)
2x2 In. 2 2 2.5 2 10.5 3 2.56 5.75 4.5
(mm) FNPT MNPT (63.5) (267) (65) (146) (114)
11
SERIES 'TM' CENTRIFUGAL 202
The Series 'TM' magnetic coupled centrifugal fail. Heavy walled voluted casings improve pump
pump directly addresses the weaknesses of other strength, internal shaft support, chemical resis-
magnetic drive pumps. From high torque compact tance, pressure and temperature capabilities as
magnets to a large diameter reduced length shaft well as hydraulic efficiencies. Standard models
to massive precision finished thrust bearings, the are non-overloading with stated elevated specific
'TM' pump is designed to excel where other pumps gravity liquids.
11
20
DIMENSIONS Inches
18 NEMA
MODEL A B C D
FRAME
16
TM6 2-5/16 6-3/4 5-5/8 3-9/16
14 TM10 56C 2-3/4 7-15/16 6-1/8 3-15/16
TM15 3-1/4 9-3/4 7-7/8 4-7/8
12 TM30 145TC 3-5/8 11 7-1/2 4-1/4
10
DIMENSIONS Inches
8
NEMA
MODEL E F G H
6 FRAME
TM6 3-1/2 7-1/16 1-13/16 6-1/2
4 TM10 56C 3-1/2 7-7/16 1-3/4 6-1/2
TM15 3-1/2 8-3/8 2-1/2 6-1/2
2
TM30 145TC 3-1/2 -- 2-1/2 --
m
Series 'TM' Polypropylene / EPDM: Polypropylene casing, impeller magnet enclosure, carbon fiber reinforced
polypropylene rear casing, silica-free ceramic shaft and stationary thrust bushings, carbon filled PTFE rotat-
ing sleeve and bushings, EPDM 'O'-ring. To order, use Price Code No. below. (Maximum operating temperature
150F Maximum operating pressure 110 psi)
FLOW MAX. FLOW1 MAX. TDH2 MAX. IMPELLER CONNECTIONS PRICE SHIPPING
HP MODEL NO.
CURVE GPM LPM ft. m S. G.3 DIA. SUCT. x DISCH. CODE NO. WT. (lbs.)
1 34 107 42 8.9 1.5 .75 3.2" 1" FNPT x 3/4" MNPT TM6-3.2 D.75 51-0100 31
2 67 211 58 12.3 1.4 1.5 3.85" 11/2" FNPT x 1" MNPT TM10-3.85 D1.5 51-0101 42
3 90 283 64 13.5 1.4 2.0 3.9" 11/2" FNPT x 11/4" MNPT TM15-3.9 D2.0 51-0102 56
4 130 409 68 14.4 1.4 3.0 4.0" 2" FNPT x 11/2" MNPT TM30-4.0 D3.0 51-0103 64
Series 'TM' PVDF / Viton: Same construction as polypropylene except PVDF casing, impeller, internal magnet
enclosure, rear casing and Viton 'O'-ring.To order PVDF / Viton pump, add -K to Model No. and Price Code No.
(Maximum operating temperature 190F. Maximum operating pressure 110 psi)
11
MAGNETIC COUPLED,
REGENERATIVE TURBINE,
HIGH HEAD, LOW FLOW FOR:
Designed for low flow, high head applications, Series non-metallic turbine pumps exhibit excellent chemi-
'TM-T' regenerative pumps provide an extremely cal resistance and they are designed to provide ex-
reliable and economical alternative to oversized tremely low wearing characteristics. Also, because
centrifugal pumps operated near shut-off with ex- of their turbine design, Series 'TM-T' pumps can be
cessive bypass and power requirements. 'TM-T' throttled to a required duty point without bypassing.
11
40
36
32
28
24
20
4
16
12
DIMENSIONS Inches
NOTE: Motor dimensions may vary. MODEL
NEMA
A B D E F
FRAME
TMT33 & TMT52 56C 5-1/2 7-3/4 1-3/8 6-5/8 3-1/2
TMT53 & TMT72 143TC 6-1/4 8-1/2 1-9/16 6-5/8 3-1/2
Series 'TM-T' Polypropylene / EPDM: Polypropylene casing, impeller magnet enclosure and rear casing. Silica-
free ceramic shaft and stationary bushing. Carbon filled PTFE rotating sleeve and bushing, EPDM 'O'-ring.
(Maximum temperature 150F, maximum pressure 110 PSI.) To order, use Price Code No. below.
FLOW MIN. FLOW1 MAX. FLOW1 MAX. TDH2 MAX. IMPELLER CONNECTIONS PRICE SHIP.
HP MODEL NO.
CURVE GPM LPM GPM LPM ft. m S. G.3 DIA. SUCT. & DISCH. CODE NO. WT. (lb.)
1 3 9.4 15 47 110 23.3 1.3 1.0 2.17" 3/4" FNPT TMT33-2.17 D1.0 51-0120 43
2 5 16 22 69 112 23.7 1.2 1.5 2.52" 1" FNPT TMT52-2.52 D1.5 51-0121 45
3 6 19 25 79 135 28.6 1.2 2.0 2.91" 1" FNPT TMT53-2.91 D2.0 51-0122 65
4 7 22 32 100 150 31.8 1.2 3.0 2.91" 1" FNPT TMT72-2.91 D3.0 51-0123 67
Series 'TM-T' PVDF / Viton: Same construction as polypropylene except PVDF casing, impeller magnet
enclosure, rear casing and Viton 'O'-ring. (Maximum temperature 195F, maximum pressure 110 PSI.)
To order PVDF / Viton pump, add -K to Model No. and Price Code No.
Powerful magnets
Seal-less pump provides zero
leakage and low friction for
energy efficiency
High efficiency closed impellers
Series 'Z' Magnetic Coupled Pumps are the latest in corrosion resistant construction of polypropylene or
magnetic coupled pump technology. Tested and proven ETFE ensures efficient and reliable performance for
design features provide a pump that is sealless and even the most critical applications. Standard TEFC
leakproof. Available materials of construction and flow motors, strong magnets and highly efficient impellers
capacity to 145 U.S. GPM make this pump an excellent provide a quiet and efficient pump designed for years
choice for a wide variety of applications. of trouble-free operation.
Standard 'Z' models have strong magnets, allowing The following information covers standard Series 'Z'
them to provide continuous flow with liquids up to 1.1 models for use with solutions to 1.1 specific gravity.
specific gravity. Trimmed impellers allow continuous For other models consult Sales Department.
flow with liquids to 1.9 specific gravity. Durable and
11
NOTE:
3450 RPM@ 60Hz
2850 RPM @ 50Hz
Flows with 1.1 specific gravity.
Z42 2 1 10.23 9.84 23.34 8.19 2.56 7.87 4.53 12.22 3.31 6.03
Z43 2 1 10.23 9.84 24.22 8.19 2.56 7.87 4.53 12.22 3.31 6.03
Z45 2 1 10.94 10.44 26.66 8.19 2.56 7.87 5.12 13.16 3.31 6.03
**Varies with motor manufacturer.
208
SERIES 'Z' PUMPS Ordering Information P-512
Pumps good to 1.1 specific gravity. TEFC, 3450 RPM, 'C' motors are 110-220V/1/60 Hz;
For heavier solutions, consult Sales Dept. for 'D' motors are 208-230-460V/3/60 Hz.
performance and operating voltage. For 50 Hz motors, add -5 to Model and Price Code Nos.
For EPDM elastomers, consult Sales Department.
* FRICTION SURFACES
MODEL SPINDLE REAR THRUST FRONT THRUST BEARING MOUTH RING
CR Ceramic Ceramic Ceramic Rulon Rulon
CHCR Ceramic Ceramic Ceramic H. D. Carb. Rulon
SCR SiC SiC SiC SiC Rulon
CCCR Ceramic Ceramic Ceramic Ceramic Rulon
11
209
Pumps good to 1.1 specific gravity. TEFC, 3450 RPM, 'C' motors are 110-220V/1/60 Hz;
For heavier solutions, consult Sales Dept. for 'D' motors are 208-230-460V/3/60 Hz.
performance and operating voltage. For 50 Hz motors, add -5 to Model and Price Code Nos.
For EPDM elastomers, consult Sales Department.
* FRICTION SURFACES
11
The Series 'TM-SS' magnetic coupled pump directly fail. Heavy walled voluted casings improve pump
addresses the weaknesses of other magnetic drive strength, internal shaft support, chemical resistance,
pumps. From high torque compact magnets to a pressure and temperature capabilities as well as
large diameter, reduced length shaft to massive hydraulic efficiencies. Standard models are non-
precision finished thrust bearings, the 'TM-SS' overloading with stated elevated specific gravity
pump is designed to excel where other pumps liquids.
and MIXING
211
DIMENSIONS Inches
NEMA
MODEL A B C
FRAME
TMSS6 2-1/4 8-1/4 6-5/8
TMSS10 56C 2-3/4 9 6-5/8
TMSS15 145TC 3-1/8 10-1/8 7-7/8
TMSS30 184TC 3-1/4 10-3/4 10-1/8
DIMENSIONS Inches
NEMA
MODEL D E F
FRAME
TMSS6 1-3/4 3-1/2 7
TMSS10 56C 1-3/4 3-1/2 7-3/8
TMSS15 145TC 2-1/2 3-1/2 8-3/8
TMSS30 184TC 2-5/8 4-1/2 10
FLOW MAX. FLOW1 MAX. TDH2 MAX. IMPELLER CONNECTIONS PRICE SHIPPING
HP MODEL NO.
CURVE GPM LPM ft. m S. G.3 DIA. SUCT. x DISCH. CODE NO. WT. (lbs.)
1 32 100 41 8.7 1.3 .75 3.13" 1" FNPT x 3/4" MNPT TMSS6-3.13 D.75 51-0110 40
2 69 218 58 12.3 1.4 2.0 3.78" 11/2" FNPT x 1" MNPT TMSS10-3.78 D2.0 51-0111 59
3 100 315 67 14.2 1.4 3.0 4.13" 11/2" FNPT x 11/4" MNPT TMSS15-4.13 D3.0 51-0112 80
4 160 505 79 16.7 1.4 5.0 4.50" 2" FNPT x 11/2" MNPT TMSS30-4.50 D5.0 51-0113 159
TO ORDER
11
EPDM, add -L to Model No. and Price Code No. Consult sales department for 50 Hz motors.
Motors are TEFC, 230 - 460V / 3 / 60Hz
To order 115 - 230V / 1 / 60, change D to C in Model No.
GPM @ 60 Hz, LPM @ 50 Hz
and add -1 to Price Code No.
ft. TDH@ 60 Hz, m TDH @ 50Hz
Motors are non-overloading at stated specific gravity.
SERIES 'UC' 212
Series 'UC' magnetic coupled pumps are seal-less, components provide exceptional chemical resistance
ANSI dimensional, ETFE lined pumps that are specifi- and wear characteristics at all flows.
cally designed for corrosive chemical applications The modied concentric volute and generous impeller
in a wide range of industrial services. balance holes equalize pressure across the entire
The Series 'UC' pump is engineered to provide the flow range, allowing minimal hydraulic thrust loads
utmost in reliability and longer pump life in even and decreased stress on the impeller. These design
the most extreme applications. All wetted surfaces innovations provide reduced wear on critical pump
are non-metallic to provide superior chemical re- components.
sistance. The Series 'UC' pump has a tough ductile Series 'UC' pumps also utilize straightening vanes
iron casing bonded with a pure Tefzel (ETFE) lining. in the suction to prevent "pre-rotation" and reduced
The enclosed impeller and pump liner are precision turbulence on the impeller for enhanced low flow
molded from carbon fiber reinforced ETFE while the operation.
pump liner also has an external containment shell
of glass reinforced vinyl ester for optimum pressure Series 'UC' magnetic coupled pumps are designed
resistance. to perform efciently with great reliability and low
maintenance requirements and to provide increased
The dual impeller bushings, shaft and front and rear productivity and minimal operating costs. In short, they
11
thrust rings are sintered silicon carbide. The impeller provide great value in critical pumping applications.
thrust ring is manufactured from Fluorosint. These
213
MODEL UC1516 (1 x 1 x 6)
MODEL UC1518 (1 x 1 x 8)
MODEL UC326 (3 x 2 x 6)
11
SPECIFICATIONS
MOTOR2 OPTIONAL
TEFC ADD TO DESCRIPTION MODEL ADD TO
RPM NEMA HORSE- PRICE PRICE
MODEL CODE NO.
FRAME POWER CODE NO.
145TC 3.0 -D3.0 3A EPDM elastomers -L L
5.0 -D5.0 2B
182/4TC
1
3450 7.5 -D7.5 2C For pump only, eliminate motor sufx from Model No.
@ 60 Hz 10.0 -D10.0 5D and sufx letter from Price Code No.
11
215TC 2
Motors are NEMA 208-230-460V/3/60 Hz, TEFC.
15.0 -D15.0 5E
For 50 Hz, IEC or EXP, consult Sales Dept.
256TC 20.0 -D20.0 6F
1725 143/5TC 1.5 -H1.5 3G
@ 60 Hz 182/4TC 3.0 -H3.0 2H
215
DIMENSIONS
A Approx.
4. 00 B C Approx.
6 .50 "
11.75 "
5.25
4" 7 1/4"
3"
6"
5/8"
TYP.
* Pump only
11
SERIES 'G' 216
12
HORIZONTAL PUMPS P-613N
The self-priming Series 'G' Pump is made in included with close-coupled electric drive pumps.
either Noryl or Ryton, providing a maximum range After initial prime, the Series 'G' Pump will lift up
of chemical resistance. It is available with 316 to 15 vertical feet (4.6m) and will remain primed
stainless steel, internal hardware or completely even after shutdown. This pump also features an
non-metallic solution contact. The pump comes open, non-clogging impeller which is molded in
standard with 304 stainless external hardware. The conjunction with the shaft sleeve, thus isolating the
pump is protected with a basket-type strainer in shaft from solution contact.
either polypropylene or ECTFE. The large cover The self-priming ability, chemical resistance,
makes initial priming and removal of the strainer light weight and basket strainer make this an ideal
quick and easy. The cover is the same material pump for chemical transfer, waste treatment, emer-
as the pump or it can be ordered in clear Lexan gency/backup or filtering.
(PCN 64-1818 90). A polypropylene baseplate is
* Based on water-like liquids @ 70F and 60 Hz (3450 RPM)
operation after initial priming of pump housing.
12
SERIES 'G' HORIZONTAL PUMPS Specications P-613N
COMBINATION
1" FNPT and 2" MNPT
8.68
(220)
10.88
(276)
6.94
(176)
4.38
(111)
Choose from:
Pumps molded of glass-reinforced Noryl with poly- Pumps molded of glass-reinforced Ryton with ECT-
A propylene basket strainer, ethylene propylene C FE basket strainer, Viton elastomers, 316 stainless
elastomers, 316 stainless steel internal hardware, steel internal hardware, 304 stainless steel external
304 stainless steel external hardware, carbon- hardware, carbon-ceramic and 316 stainless steel
ceramic and 316 stainless steel mechanical seal. mechanical seal.
Same as A but with non-metallic solution con- Same as C but with non-metallic solution contact
B tact and ECTFE / EPDM / siliconized-graphite
D and ECTFE / Viton / siliconized-graphite non-metallic
non-metallic mechanical seal. mechanical seal.
12
CENTRIFUGAL PUMPS P-630B
SELF-PRIMING CENTRIFUGAL
PUMPS FOR TRANSFER AND
RECIRCULATION OF:
CHEMICAL SOLUTIONS
WASTE TREATMENT
ACIDS / INDUSTRIAL LIQUIDS
Choice of materials -
glass reinforced polyester, polypropylene or
Ryton with 316 SS internal hardware
(See a chemical resistance chart)
The Series 'S' Self-Priming Centrifugal Pump is a The self priming capability and chemical resis-
chemically resistant pump for general service on tance make this an ideal chemical transfer, waste
water, salt water, mild acids and bases. It is offered treatment, and emergency / backup pump.
in a choice of glass reinforced polyester, polypro- * Based on water-like liquids at 70F and at 3450 RPM
pylene or Ryton construction to provide a maxi- after initial priming of pump housing.
mum range of chemical resistance. It is available
with a choice of elastomers and 316 stainless steel
internal hardware or with completely non-metallic
solution contact. The pump comes standard with
304 stainless external hardware.
All pumps include a built-in check valve and fea-
ture a self-cleaning double volute which allows
the Series 'S' pump to self prime and lift to 25 ft. WASTE TREATMENT SOLUTION
TRANSFER
220
12
SERIES 'S' PUMPS Specifications P-630B
DIMENSIONS
12
9-15/16
1" & 2" Pumps
to 3.0 HP
(3 phase) 5 1/4
33/4
3 3/4 3 3/4 12-5/16 12-5/16
1
11-5/8
221/2 (2)
25 (3)
33/4 (2)
6 (3) 1-1/8 33/4 33/4
51/2 (2)
8 (3)
131/4
24 / 1 4
221
12
SERIES 'S' PUMPS Ordering information P-630B
Pump molded of glass reinforced polyester with 316 stainless steel internal fasteners, 304 SS external fasteners,
TABLE I EPDM "O"-rings and gasket, check valve, polypropylene baseplate, close coupled electric motor.
ELECTRIC MOTOR 60 Hz
PORT MAX. MAX. MAX. ADD TO MODEL &
FLOW PRICE PRICE CODE NO . . .
SIZE FLOW RATE TDH HP REQ'D MODEL
CURVE CODE
NUMBER 115/230V/1/60 230/460V/3/60
LETTER NUMBER
GPM @ LPM @ FT. @ m@ 60 Hz 50 Hz
IN. TEFC TEFC
60 Hz 50 Hz 60 Hz 50 Hz /RPM /RPM
A 11/2 50 157 22 4.4 0.5/1750 0.3/1450 SE11/2AL- 64-11A4- G.5C H.5C
C 11/2 70 219 27 5.6 1.0/1750 0.6/1450 SE11/2CL- 64-11C4- G1.0C H1.0C
E 2 110 344 62 13.0 1.4/3450 0.8/2850 SE2EL- 64-12E4- C2.0C D2.0C
F 2 150 471 105 21.9 3.0/3450 1.7/2850 SE2FL- 64-12F4- -- D5.0C
H 2 155 485 82 17.1 2.6/3450 1.5/2850 SE2HL- 64-12H4- -- D3.0C
I 2 195 610 120 25.0 5.0/3450 2.8/2850 SE2IL- 64-12I4- -- D5.0C
J 2 185 579 83 17.3 4.0/3450 2.3/2850 SE2JL- 64-12J4- -- D5.0C
L 3 270 845 79 16.5 5.0/3450 2.8/2850 SE3LL- 64-13L4- -- D5.0C
TABLE II
To determine pump-motor for a selected GPM and/or TDH, Multiply HP req'd shown in Table I by specic gravity to determine
rst select the appropriate impeller from curve on the previous motor size. Select pump materials. Then construct Model and
page. Use Table I to identify the part size for a given ow curve. Price Code Numbers.
For BSP threads, add B in 4th digit of Model No. and change
ELECTRIC MOTORS 60 Hz Price Code No. from 1 to 4, 2 to 5, 3 to 6. Note: Impeller
designation now becomes the 5th digit of model number
ADD TO MODEL &
PRICE CODE NO . . .
only for BSP pumps.
HP RPM Polypropylene pump includes Ryton volute.
115/230V/1/60 230/460V/3/60
TEFC TEFC For 50 Hz operation consult Sales Department.
.5 1750 G.5C H.5C
.75 1750 G.75C H.75C
1.0 1750 G1.0C H1.0C
1.5 1750 G1.5C H1.5C
2.0 3450 C2.0 D2.0C
3.0 3450 -- D3.0C
5.0 3450 -- D5.0C
222
12
SERIES "S" PUMPS - HYDRAULIC, PNEUMATIC OR ENGINE DRIVE P-630B
PNEUMATIC
SERIES 'I' SELF-PRIMING 223
12
CENTRIFUGAL PUMPS P-631B
EFFICIENT
LIGHTWEIGHT
CHEMICALLY RESISTANT
CHEMICALS / WASTES
ACIDS / INDUSTRIAL LIQUIDS
CLOSE-COUPLED OILFIELD / AQUACULTURE
ELECTRIC
AGRICULTURE
FLOW CURVES
12
CENTRIFUGAL PUMPS P-632A
HORIZONTAL . . .
LONG or CLOSE COUPLED
FOR:
MATERIALS -
Pump casing made of rugged glass reinforced
polyester
Buna-N elastomers and stainless steel fasteners
PEDESTAL MOUNTED
for flexible coupling
Series 'T' Self-Priming Centrifugal Pumps are lightweight,
chemically resistant pumps for general service on water,
salt water and mildly corrosive liquids containing solids.
They will pass a solid 1/3 the diameter of the suction port.
'T' Pumps feature tough non-metallic impeller, steel volute
and wearplate with non-metallic coating, 316 stainless steel
internal fasteners and 304 stainless steel quick release
housing clamp. Housing is rugged glass reinforced polyes-
ter. Pressurized oil lubrication system protects hard silicon
carbide shaft seal faces. "O"-rings and gasket are Buna-N.
Engine driven pumps include spring mounted base rails.
All pumps include a built-in check valve, feature easy
FLEXIBLE COUPLED servicing and during pumping, a self-cleaning double
TO ELECTRIC DRIVE volute keeps pump free of settled solids.
*Based on water-like liquids at 70F and at 3450 RPM after initial priming
of pump housing.
226
12
SERIES 'T' SELF-PRIMING PUMP specifications P-632A
FLOW CURVES
SERIES 'SP' 227
12
HORIZONTAL PUMPS P-600C
SELF-PRIMING CENTRIFUGAL
PUMPS FOR TRANSFER AND
RECIRCULATION OF:
CHEMICAL SOLUTIONS
WASTE TREATMENT
AGRICULTURAL SOLUTIONS
GROUND WATER
Self-priming Series 'SP' pumps are constructed After initial prime, the Series 'SP' pump will lift
of cast iron for dependable duty in a variety of ap- up to 20 vertical feet (6.1m) and will remain primed
plications. The pumps include a 316 stainless steel even after shutdown. The self-priming ability, along
shaft, 316 stainless steel fasteners, synthetic fiber with compact design, make Series 'SP' pumps ideal
gaskets and cast iron mounting bracket. They feature for chemical transfer, waste water treatment, emer-
a semi-open impeller which is also constructed of 316 gency/backup or filter pumping.
stainless steel. Motors are standard NEMA 56C face,
3450 RPM @ 60 Hz or 2850 RPM @ 50 Hz, TEFC.
TABLE II
Determine pump-motor model for a specified GPM, TDH, Read required horsepower at right ordinate and multiply by
mechanical seal and specific gravity. Select performance point specific gravity. Select pump model components and Price
on curve and size horsepower from corresponding numbered Code Numbers from Table II.
dotted line vertically above or below performance point.
PUMP IMPELLER "O"-RING & MECHANICAL SEAL TEFC MOTOR (3450/2850)
MODEL PRICE FLOW ADD TO . . . ADD TO . . . SINGLE PHASE THREE PHASE
CODE NO. CURVE MODEL PRICE MATERIAL MODEL PRICE ADD TO . . . ADD TO . . .
NUMBER CODE NO. (SOLUTION CONTACT) NUMBER CODE NO. HP PRICE PRICE
SP-150 61-07 MODEL MODEL
1 1 1 CODE NO. CODE NO.
EPDM, carbon, ceramic L(M1) 1
2 2 2 1.0 -C1.0 A -D1.0 C
Viton, carbon, ceramic V(M2) 2
3 3 3 1.5 -C1.5 B -D1.5 D
4 4 4 2.0 -D2.0 E
Single phase - 115-208-230V/1/60 or 220-440V/1/50 3.0 -D3.0 F
Three phase - 208-230-460V/3/60 or 380-415V/3/50
For 50 Hz, add -50 to Model No. and add 5 to Price
Code No.
DIMENSIONS
1-1/2" NPT
AG 7-1/8 DISCHARGE
2-13/16 1-1/2" NPT MOTOR END DIMENSIONS
SUCTION (Inches)
MOTOR HP
2 3450 RPM 56C FRM
XP AG FP P XP
7/16
CLARIFICATION and 229
13
Suitable for:
Select SOLID / LIQUID SEPARATION,
series or
parallel flow 1-5
micron CARBON ADSORPTION and
15 - 30
ION EXCHANGE RESIN
micron
SERFILCO recognizes the fact that not every liquid The nature of the particles is also a key consideration.
clarification requirement can be met with a pre- Are the particles "slimy", blinding off the media at
packaged filtration system. That is why we offer a the surface or will they remain porous and sand-like
range of standard, off-the-shelf filter chambers and a and develop a thick cake which, in turn, enhances
broad selection of filter media, such as bags, discs, the filtration / separation efficiency by removing
depth and pleated cartridges, cleanable sleeves and finer and finer particles as the cake develops? The
carbon or resin purification to give you the flexibility answers to these questions will lead to the choice
you need to meet your clarification / purification of filter media.
requirements. By using different combinations of The common perception is that bag filters continue
chambers and media, configured for recirculatory to retain contaminant until they are filled to capac-
or in-line filtration, you can achieve the level of ity and puffed up like a vacuum cleaner bag. This
clarification / purification desired. is generally not the reality of bag filtration. Instead,
The selection of the most effective combination of once the pores on the surface of the bag plug with
elements for particle / liquid separation or purifica- fines, the bag needs to be cleaned for re-use. As a
tion depends upon a number of factors, including result, such a filtration system becomes very main-
the size and nature of the particles to be removed. tenance intensive.
Determination of particle size is necessary to properly On the other hand, systems which use depth type
select the micron retention level of the filter media to lter media require very little maintenance because
be used. Through pilot testing or experimentation, depth type lters provide a high ow rate over more
this level can be determined. Often, the filtration ef- than 80% of their life before the ow rate is reduced to
ficiency of existing equipment can be improved by a level where cartridge maintenance is necessary.
adding a filter chamber with coarse media upstream
of the existing chamber to remove a large portion The following pages identify some of the lter cham-
of the contaminants and thereby extend the life of bers and lter media available from SERFILCO. We
the denser, more costly media in the downstream have included a number of schematics to help you
filter chamber. understand the variety of approaches that can be
used to meet your clarication / purication needs.
230
50 - 100
micron
F
I
L
T
E
R
1 MICRON 1 MICRON
NOMINAL ABSOLUTE
FINAL FILTER
5 OR 10 MICRON
PRE-FILTER
CARBON OR RESIN
PURIFICATION
FILTER CHAMBER SIZING & 231
13
IN ADDITION TO THE QUESTION OF IN-LINE OR RECIRCULATORY INSTALLATION OF A FILTER FOR
YOUR SOLUTION, CHAMBER SIZING CAN MAKE A SIGNIFICANT CONTRIBUTION TO THE ECONOMICS
OF THE FILTRATION PROCESS.
For example...
using a instead of a reduces cartridge con-
12 cartridge filter 9 cartridge filter sumption by 13%
9 6 18%
6 3 29% * Based on average sizing
9 3 42% [i.e. 1 - 10 (25cm)
cartridge per 50 gallons (200 L]
12 3 50%
15 3 55%
232
SERIES GPO, GNO & GSO
MOLDED PLASTIC FILTER CHAMBERS C-101J
13
These sturdy and quality built two- GPO models are molded from reinforced GNO is for high temperature service.
piece filter housings are designed to polypropylene for water and chemi-
meet the need for reliable, long last- cal compatibility. Blue body with black MODEL GNO10-3/4
ing and convenient use. They provide cover.
extended service life and dependable Molded from glass fiber reinforced ny-
performance. Pipeline mounted cap, and MODEL GPO10-3/4 lon. Red body and cover. For 10" long
body-nested Buna N O-ring provide depth or 9-3/4" long pleated or carbon
For 9-3/4" or 10" long depth cartridges, or 9- cartridges.
ease of installation and quick- change
3/4" long pleated or carbon cartridges.
cartridge replacement. Housings pass
Water Conditioning Federations rec-
ommended standards for hydrostatic GSO provides unobstructed observation
MODEL GPO20-3/4 of process fluid.
leak and burst pressures. For complete
specifications, refer to table below. For 19-3/4" or 20" long depth cartridges,
All chambers accept most standard or 19-3/4" long pleated or carbon MODEL GSO10-3/4
filter cartridges: depth type, pleated area, cartridges.
Blue cover molded from reinforced
carbon, and refillable mini-canisters.
MODEL GPO10-1 polypropylene. Shell molded from
Order cartridges separately. To select
clear styrene acryl nitrile. For 10" long
media, micron retention and style, refer For 9-3/4" or 10" long depth carbon or depth or 9-3/4" long pleated or carbon
to SERFILCO catalog. pleated cartridges up to 4-5/8" diameter. cartridges.
13
FOR FILTRATION & PURIFICATION OF
PROCESS SOLUTIONS:
FEATURES:
Non-metallic solution contact CPVC, polypropylene,
PVC and pure PVDF construction
(See a chemical resistance chart)
Heavy duty construction
Pressure ratings to 160 PSI (1103 KPa)
(See Pressure/temperature table on next page)
Clamp ring closure or optional external tie rod
Variety of sizes
From 4", 6" and 1 to 4 - 10" cartridge capacity
CPCL20
(or equivalent 20", 30", or 40" lengths.)
Port sizes " and 1" NPT
Metric and flange available
"O"-ring seal at cover & vent valve
EPDM (standard), Viton (optional)
Easy servicing, no tools required
For use with a variety of lter media (order separately)
Depth wound, pleated, carbon or membrane
cartridges
CCL40 Positive cartridge seal for -
Standard - DOE . . . Double Open End
Optional - SOE . . . Single Open End for 222 "O"-ring
Cleanable sleeves (used with or without precoat)
FLOW RATE
DIMENSIONS
CHAMBER CARTRIDGES - Max. dia. 3" SLEEVE SET (CPVC & POLYPROPYLENE)
HEIGHT SHIPPING WT. SIZE & NUMBER SOLIDS LENGTH SOLIDS AREA PRICE
SIZE
in. lbs. 4" 6" 10" 20" 30" 40" AREA in. sq. ft. CODE NO.
4 7 3 1 1.4
6 9 4 1 2.1
10 13 5 1 3.5 10 0.6 78-0191
20 23 7 2 1 7.0 20 1.2 78-0192
30 33 9 3 1 10.5 30 1.8 78-0193
40 43 11 4 2 1 14.0 40 2.4 78-0197
OPTIONAL
TO ORDER DESCRIPTION ADD to MODEL NO. ADD to PRICE CODE NO.
Viton elastomers Change L to V in Model Number. -V
Mounting bracket Adjustable: 9" x 5" PVC 44-3200-1
Cover plate Standard on models with tie rod cover closure.
99-1099-1
(Recommended above 120oF at 75% of max. pressure)
222 "O"-ring cartridge seat For SOE (single open and at top) cartridge. Cross post not furnished. -2 -2
Pressure gauge Mounted in cover with EPDM diaphragm & vent valve. Polypropylene -G4A 99-1399
0-60 PSI CPVC -G4A 99-0733
Mounted in cover with Viton diaphragm & vent plug PVDF -G4 99-1222
Tie rod cover closure Drop rst C from Model Number and C from Price Code Number
235
SERIES 'S' PLASTIC
CARTRIDGE FILTER CHAMBERS C-106S
13
For ltration & purication of process solutions:
WATER TREATMENT / FOOD PROCESSING
CLEANING / PHOTOGRAPHIC
ELECTROPLATING / PHARMACEUTICAL
CHEMICAL / PETROCHEMICAL / BEVERAGE
These filter chambers are designed for filtering process solutions where
clarification will extend operating life and improve quality.
FEATURES:
Non-metallic solution contact
(See a chemical resistance chart)
CPVC, polypropylene, PVC and pure PVDF construction
Heavy duty construction
Pressure ratings to 135 PSI (931 KPa)
(See Pressure/temperature table on next page)
0-60 PSI pressure gauge, mounted on a gauge guard
SS swing bolt closure with tee handles on PVC and CPVC models
SS tie rod closure for polypropylene and PVDF models
Integral shell-base assembly
Inlet to outlet at 90 or 180 aspect
Variety of sizes are available
From 3 to 15 - 10"cartridge capacity
(or equivalent 20", 30", or 40" lengths.)
Port sizes 1" NPT & 1" MNPT
Model PL60(2)S-1-G3 Flange, socket, 1" BSP and metric available
Model PPL30(1)-1-G3
DIMENSIONS
CHAMBER CARTRIDGES - Max. dia. 2.7" SLEEVE SET (CPVC & POLYPROPYLENE)
SIZE HEIGHT SHIPPING WT. SIZE & NUMBER SOLIDS LENGTH SOLIDS AREA PRICE
in. mm lbs. kg 10" 20" 30" 40" AREA sq. ft. in. sq. ft. CODE NO.
30(1) 19 495 13 6 3 10.5 10 1.8 78-0194
60(2) 29 749 25 11 6 3 21.0 20 3.6 78-0195
90(3) 39 1003 38 17 9 3 31.5 30 5.4 78-0196
120(4) 49 1257 50 23 12 6 3 42.0 40 7.2 78-0416
150(5) 59 1511 62 29 15 3 & 3 52.5 50 9.0 78-0418
OPTIONAL
13
WATER TREATMENT / PARTS WASHERS
VENDING / PHOTOGRAPHIC
CIRCUIT BOARD SCRUBBING
CHEMICAL MILLING / WASTE TREATMENT
FEATURES:
Non-metallic solution contact
CPVC, PVC or polypropylene construction
EPDM elastomers standard. Viton optional
(See a chemical resistance chart)
The Series 'SD' Filter Chambers provide versatility The multi-cartridge chamber holds 3 to 12 standard
and ease of operation for the ltration and purication depth wound cartridges. Both designs feature
of various process solutions. The Series 'SD' single non-metalic solution contact and are available in
cartridge chamber will accept a 4" diameter pleated PVC, CPVC or polypropylene construction. These
cartridge, two 4" dia. depth wound cartridges, or a chambers also feature a screw top cover closure for
single carbon canister for granular carbon or resin. quick and easy cartridge change.
50-100
MICRON
238
48 3/4"
5/8"
9/16"
1 1/2
To order chamber with Viton 'O'-ring, change L to V in Model No. and add -V to Price Code No.
4" dia. x 18" long polypropylene or unbleached cotton See Bulletin M-109
239
13
FLOW RATE VS. PRESSURE
DIFFERENTIAL WITH 15 MICRON
DEPTH WOUND CARTRIDGES
CPVC base and cover, CPVC shell sealed to base. EPDM 'O'-ring at cover and poly- CL30(1)P-1 78-1300 C
CL60(1)P-1 78-1301 C
CL propylene vent plug. CPVC internals. CPVC cartridge guides, caps and drain plugs.
CL90(1)P-1 78-1302 C
For DOE cartridges. CL120(1)P-1 78-1303 C
Polypropylene base and Ryton cover. Polypropylene shell sealed to base. EPDM 'O'- PPL30(1)P-1 78-1300PP
PPL60(1)P-1 78-1301PP
PPL ring at cover and polypropylene vent plug. PP internals. PP cartridge guides, caps
PPL90(1)P-1 78-1302PP
and drain plugs. For DOE cartridges. PPL120(1)P-1 78-1303PP
To order chamber with Viton 'O'-ring, change L to V in Model No. and add -V to Price Code No.
DIMENSIONS
HEIGHT (A) SHIPPING WT SIZE & NUMBER Solids LENGTH SOLIDS PRICE
SIZE Area in. AREA CODE NO.
in. mm. lbs. kg. 10" 20" 30" 40" sq. ft. sq. ft.
30(1) 16-5/8 422 13 6 3 - - - 10.5 10 1.8 78-0194
60(2) 26-5/8 676 25 11 6 3 - - 21.0 20 3.6 78-0195
90(3) 36-5/8 930 38 17 9 - 3 - 31.5 30 5.4 78-0196
120(4) 46-5/8 1184 50 23 12 6 - 3 42.0 40 7.2 78-0416
SERIES 'G' PLASTIC 240
FEATURES:
Non-metallic solution contact
CPVC, PVC or polypropylene construction
(See a chemical resistance chart)
EPDM elastomers standard, Viton optional
Heavy duty construction
Pressure ratings to 80 PSI (552 KPa)
Positive "O"-ring seal at base and cover
Cartridge guides with screw-on caps for
positive cartridge seal
Stainless steel external hardware
0-60 PSI pressure gauge with gauge guard
and vent valve
Cartridge capacity
From 12 to 60 - 10" cartridge capacity
(or equivalent 20", 30", or 40" lengths)
FLOW RATE
Easy service
Flow rates to 125 GPM depending upon size of
Swing bolt cover closure with tee handles
chamber, style of filter cartridge, solids content,
no tools required
viscosity, pressure drop and degree of clarity
desired. Pressure ratings of filter chambers depend Port size 1" NPT
upon the temperature of solutions being filtered. BSP optional
See table.
50-100
MICRON
241
13
All chambers have cover swing bolts with tee handles, guides with screw-on cap, 0-60 PSI pressure gauge
stainless steel swing bolt and hold down brackets; with gauge guard, EPDM gaskets and drain plugs. All
FRP top and bottom reinforcing plate, cartridge fasteners are stainless steel. For DOE cartridges.
SLEEVE SET
CPVC &
PRICE NUMBER POLYPROPYLENE SHIPPING
MODEL
DESCRIPTION CODE of 10" SOLIDS* WEIGHT
NUMBER SOLIDS
NUMBER CARTS Add lbs.
AREA
CONNS. PCN
sq. ft.
PL120SIO 1-G3A 78-1901P 12 42 7.2 78-0209 82
CPVC base and
PL240SIO 1-G3A 78-1902P 24 84 14.4 78-0201 89
cover, PVC shell,
PL 1" NPT PL360SIO 1-G3A 78-1903P 36 126 21.6 78-0202 97
CPVC vent valve
PL480SIO 1-G3A 78-1904P 48 168 28.8 78-0203 104
and internals.
PL600SIO 1-G3A 78-1905P 60 210 36.0 78-0204 112
CL120SIO 1-G3A 78-1901C 12 42 7.2 78-0209 82
CPVC base, cover, CL240SIO 1-G3A 78-1902C 24 84 14.4 78-0201 89
CL shell, vent valve 1" NPT CL360SIO 1-G3A 78-1903C 36 126 21.6 78-0202 97
and internals. CL480SIO 1-G3A 78-1904C 48 168 28.8 78-0203 104
CL600SIO 1-G3A 78-1905C 60 210 36.0 78-0204 112
PPL120SIO 1-G3A 78-1901PP 12 42 7.2 78-0209 82
Polypropylene
PPL240SIO 1-G3A 78-1902PP 24 84 14.4 78-0201 89
base, cover and
PPL 1" NPT PPL360SIO 1-G3A 78-1903PP 36 126 21.6 78-0202 97
shell, CPVC vent
PPL480SIO 1-G3A 78-1904PP 48 168 28.8 78-0203 104
valve and internals.
PPL600SIO 1-G3A 78-1905PP 60 210 36.0 78-0204 112
* For each 10" length, the solids holding capacity is 3" sq ft of surface media of the same porosity
OPTIONAL
DIMENSIONS
1 1/2" INLET
2"
15/16" 15/16"
1 1/2" INLET 1 1/2" OUTLET
1 1/2" DRAIN
3" 3/4" EFFLUENT
DRAIN 1 5/8"
14 3/4"
PRESSURE / TEMPERATURE
70oF 80 75 80
100oF 75 60 75
120oF 40 50 70
140oF 25 40 55 1
Maximum differential pressure from inlet to outlet
170oF 15 35 (across separator plate) is 40 PSI at 68 F.
200oF 30 2
With 15 micron depth wound cartridges.
243
SERIES 'GC' PLASTIC
CARTRIDGE FILTER CHAMBERS C-113A
13
For: ACID / AQUEOUS / CHEMICAL
ELECTROPLATING / WASTE TREATMENT
50-100
MICRON
244
SERIES 'GC' FILTER CHAMBERS Specifications, Dimensions and Ordering Information C-113A
13
FLOW PRESSURE
vs.
RATE DIFFERENTIAL
115 GPM @ 5 PSI
145 GPM @ 15 PSI
MAXIMUM
PSI @ OPERATING
PVC CPVC TEMP.
80 80 70F
75 75 100F
40 70 120F
25 55 140F
35 170F
30 200F
13
For: WATER TREATMENT / FOOD PROCESSING
CLEANING / PHOTOGRAPHIC
ELECTROPLATING / PHARMACEUTICAL
CHEMICAL / PETROCHEMICAL / BEVERAGE
FEATURES:
Non-metallic solution contact
(See Chemical Resistance Chart, Bulletin T-102)
CPVC, PVC, polypropylene and pure
PVDF construction
Heavy duty construction
Pressure ratings to 140 PSI (965 KPa)
(See Pressure/temperature table)
Tee handles - No tools required
Pressure gauge with vent valve or plug
mounted on a gauge guard with diaphragm
For use with a variety of filter media High Pressure & High Flow
SS tie rod cover closure & SS bracket
(order separately)
Depth wound, pleated, carbon or Variety of sizes are available
membrane cartridges From 4 to 55 - 10" cartridge capacity
(or equivalent 20", 30", or 40" lengths)
Positive cartridge seal for
Port sizes 1", 2" & 3" NPT
Standard - DOE . . . Double Open End
BSP, flange, socket available
Optional - SOE . . . Single Open End
Drain ports for influent & effluent
for 222 "O"-ring
Cleanable sleeves (used with or Gasket seal at cover & base
without precoat) EPDM standard, Viton optional
50-100
MICRON
246
PRESSURE/TEMPERATURE
OPTIONAL
ADD TO ADD TO
TO ORDER TO ORDER
MODEL NO. PRICE CODE NO. MODEL NO. PRICE CODE NO.
Flange connections: 1" 78-0458
222 "O"-ring seat for SOE
CPVC 2" -F 78-0459
(Single open end flat top)
3" 78-1344 -2 -2
cartridge. Top seats,
Viton elastomers change L to V -V springs and cross posts not
furnished.
Socket connections Consult Sales Department
247
13
DIMENSIONS
B C CARTRIDGES* CLEANABLE
CHAMBER PORT
FIGURE WIDTH HEIGHT SLEEVES
MODEL SIZE
in. in. LENGTH
10" 20" 30" 40" NO.
in.
KL40 1F 21 4 - - - 10
13
KL80 1F 1" 31 8 or 4 - - 20
A INCLUDES 4
KL120 1F FLANGE 41 12 - or 4 - 30
FLANGES
KL160 1F 51 16 or 8 - or 4 40
CL, PL50 1 20 5 - - - 10
CL, PL100 1 10 30 10 or 5 - - 20
B CL, PL150 1
1" NPT
40 15 - or
5
SQUARE 5 - 30
CL, PL200 1 50 20 or 10 - or 5 40
PPL, KL70 2F 24 7 - - - 10
PPL, KL140 2F 2" 14 34 14 or 7
C - - 20
FLANGE INCLUDES 7
PPL, KL210 2F 44 21 - or 7 - 30
FLANGES
PPL, KL280 2F 54 28 or 14 - or 7 40
CL, PL 2 31 22 or 11 - - 20
CL, PL 2 2" 15 41 33 - or 11 - 30
D CL, PL 2 NPT SQUARE 51 44 or 22 - or 11 11 40
CL, PL 2 61 55 or 11 + 11 - 50
CL, PL 3 42 33 - 11 - 30
15
E CL, PL 3 3" NPT 52 44 or 22 - or 11 40
SQUARE 11
CL, PL 3 62 55 or 11 + 11 - 50
* Maximum cartridge diameter: All PPL and PL & CL 50, 100, 150 & 200 - 2-5/8 inches. All others - 2-3/4 inches.
248
SERIES 'HD' PLASTIC
CARTRIDGE FILTER CHAMBERS C-111B
13
For:
ELECTRONIC MANUFACTURING,
PHARMACEUTICALS, FOOD & BEVERAGE
FEATURES
High purity non-metallic solution contact
Precision CNC machined from premium grade
PVDF or natural pure polypropylene
Proven durability and ease of service
Standard heavy duty flange connections for ease
of installation and trouble-free operation
Standard 0-60 PSI gauge, air vent valve and
drain port
For use with standard 10", 20", 30" or 40" single
open end (SOE) 222 style filter cartridges
Flow rates to 150 GPM
BENEFITS
SPECIFICATIONS
SERIES 'HD' filter chambers are precision CNC machined from high purity PVDF or natural pure poly-
propylene. Chambers feature a swing bolt cover closure with 'T'-handles for ease of cartridge service
no tools are required. Precision machined covers feature FRP reinforcing plate to ensure positive
liquid containment. Standard 0 - 60 PSI gauge guard, vent valve and drain port are designed to simplify
operation and maintenance. Standard flange connections are 1" with rugged 316 stainless steel
back plates for ease of installation and to ensure leak-free operation. All external fasteners are 316
stainless steel; standard elastomers are EPDM. Chambers are designed for use with 4 - 10", 20", 30"
or 40" SOE style filter cartridges.
249
13
FLOW RATE vs. PSI
DIMENSIONS 70 GPM = 5 P
125 GPM = 15 P
1-1/4"
2-1/4"
NOTE: For Viton elastomers, change L to V in Model and Price Code No.
* Cartridges ordered separately. Refer to Bulletin M-207-2.
SERIES 'HF' PLASTIC 250
CHEMICAL, ELECTROPLATING,
WASTE TREATMENT, WATER
TREATMENT, COOLING TOWER,
AQUACULTURE
FEATURES:
Rugged construction, non-metallic
solution contact
Flows to 400 GPM
High capacity
26 - 20", 30", 40" or 50" filter cartridges
Standard 0-60 psi gauge with guard,
air vent valve and drain port
Low pressure drop
4 psi @ 200 GPM
'T'-handle cover closure
no tools required to change cartridges
BENEFITS:
Long service life
will not rust or corrode
Continuous high flow particle removal
improves your process and finished
goods
Long intervals between cartridge
changes reduces maintenance cost.
Easy to operate and install.
Efficient to operate
low pressure differential
13
SERIES 'HF' chambers feature precision CNC ma- to change cartridges). Shell is 18" diameter and will
chined base and cover. The innovative base design hold 26 - 20", 30", 40" or 50"* D.O.E. (double open
has 3" inlet and outlet ports providing low pressure end) style cartridges. Internals included are CPVC
differential. Base includes a 1 " plugged drain port cross posts and polypropylene cap springs to ensure
for ease of maintenance. Cover includes vent valve, proper cartridge location and eliminate solution by-
0-60 psi pressure gauge with guard assembly, and pass. Base, shell and cover are PVC for totally non-
stainless steel cover plate. Cover is secured with metallic solution contact. Elastomers are EPDM and
swing bolts and 'T'-handles (no tools are required all external hardware is stainless steel.
DIMENSIONS
TOP VIEW
PL520(2)SH-3-G3A 26 - 20" 215 38" (965 mm) 78-1662 FLOW RATE vs. PSI
PL780(3)SH-3-G3A 26 - 30" 235 48" (1219 mm) 78-1663 200 GPM = 4 P
PL1040(4)SH-3-G3A 26 - 40" 255 58" (1473 mm) 78-1664 310 GPM = 10 P
PL1300(5)SH-3-G3A 26 - 50"* 275 68" (1595 mm) 78-1665
For Viton elastomers, add -V to Price Code Number * 50" lengths are achieved by pairing a 20" cartridge with a
and change L to V in Model Number 30" cartridge or a 10" cartridge with a 40" cartridge.
SERIES 'WT' PLASTIC 252
FEATURES:
Non-metallic solution contact
for acids or alkalies
(See a chemical resistance chart)
Heavy duty construction
Rated 125 PSI at 70F (8.5 BAR @ 21C)
50 PSI at 120F (3.4 BAR @ 49C)
ABS / PVC construction
with EPDM "O"-ring (Viton optional)
Four model sizes available
for 9", 10", 20", 30" and 40" cartridges
2" NPT inlet and outlet
with 1/2" NPT drain and 1/4" NPT vent
with choice of outlet direction
Available with BSP and flange connections
Quick opening for easy servicing
For use with a variety of filter media:
Depth wound, pleated, carbon and membrane cartridges
MODEL PL210S-2
Positive cartridge seal for -
Standard - DOE (Double Open End) or
Optional - SOE (Single Open End) for 222 "O"-ring
Cleanable sleeves (used with or without precoat)
Cartridges must be ordered separately. Refer to Filter Media.
13
DESCRIPTION MODEL NUMBER PRICE CODE NUMBER
Floor standing unit constructed of high luster white PVC and ABS. PL70S-2 78-1150 A
Includes EPDM "O"-ring, stainless steel swing bolt cover closure, with PL140S-2 78-1151 A
vinyl coated bracket and chrome plated eye nuts. Inlet/outlet connec- PL210S-2 78-1152 A
tions for 2" NPT, 1/2" NPT drain, 1/4" NPT vent plug. PL280S-2 78-1153 A
Optional
A
Gauge Guard
4-1/2 Assembly
(114)
Cover
FLOW RATE *
Swing Bolt @ PRESSURE DIFFERENTIAL
w/Eye Nut B GPM LPM PSI Bar
B 35 132 1 .07
OPTIONAL
OUTLET POSITIONS 70 265 1 .07
105 397 2 .14
7-3/8 Shell-Base
(187) Assembly 140 530 2 .14
2" NPT C
Inlet
BOTTOM VIEW * Using 10 micron polypropylene
1/2" NPT depth cartridges, 5 GPM/10" length.
Drain Plug
Deck Mounting
Cleats (optional)
7 2" NPT 12-3/4" Dia. B.C.
(177) Outlet (324 mm)
16-1/4 STANDARD
(413)
INLET
4-3/4 STANDARD
(120) OUTLET
10-3/4
BOTTOM VIEW
(273)
SPECIFICATIONS
CARTRIDGE SOLIDS MAXIMUM MAXIMUM PSI AT
MODEL HEIGHT B SHIPPING WT.
CAPACITY DEPTH AREA FLOW OPERATING TEMP.
NUMBER
Inches mm Lbs. Kg. 10 inch Unit length Sq. ft. U.S. GPM LPM Temp. Max. PSI
PL70S-2 29-3/8 746 55 25 7 7 of 10" 24.5 70 265 ALL 70F 125
PL140S-2 39-3/8 1000 60 27 14 7 of 20" 49.0 100 378 MODELS 100F 77
PL210S-2 49-3/8 1254 65 29 21 7 of 30" 73.5 140 530 120F 50
PL280S-2 59-3/8 1508 75 34 28 7 of 40" 98.0 140 530 140F 28
OPTIONAL
ADD to USE SEPARATE
DESCRIPTION MODEL NO. PRICE CODE NO.
Pressure gauge, 0-160 PSI, on polypropylene gauge guard with diaphragm and CPVC vent valve -G7 78-0078
Outlet direction A, B or C N/C
Viton "O"-ring -V 78-1121
Connections - Flange, 2" PVC -F 78-1122
2" BSP -BSP Consult Sales Dept.
316 stainless steel swing bolts, clevis pins, hex lock nuts and washers -SS 78-1123
Deck anchor cleats (set of three) -D 78-1124A
CPVC cross post set (to stack 10" & 20" cartridges) For Model: PL140S-2 C2 78-1125A
Fits into standard tube guides PL210S-2 C3 78-1125B
PL280S-2 C4 78-1125C
Ultraviolet outdoor weather jacket For Model: PL70S-2 88-1318 1
PL140S-2 UV 88-1318 2
PL210S-2 88-1318 3
PL280S-2 88-1318 4
Seats for SOE (Single Open End) cartridges with 222 "O"-ring -2 Add to PCN
-2
SERIES FRP PLASTIC 254
Series FRP Filter Chambers provide economical SOE cartridges2. They also accept carbon cartridges.
particulate removal and extend the useful life of An optional CPVC cross post set can be ordered for
solutions through clarification. They are constructed stacking 10 or 20 DOE cartridges.
of thermoset plastic resin reinforced with continu-
ous filament wound fiberglass to offer the strongest FRP chambers use vinyl coated 316 stainless steel
FRP composite obtainable. No pigments or fillers springs and CPVC cartridge seats to provide positive
are used, making these chambers suitable for a seating. 304 stainless steel swing bolts and polyester
wide range of liquids. Standard models have EPDM T-handles facilitate quick opening of cover closure.
O-rings (Viton optional) and CPVC internals for Chambers include 304 stainless steel mounting legs.
non-metallic solution contact. Models have FNPT inlet and outlet connections.
Optional flange connections available.
All FRPmodels include CPVC tube guides which
accept 30 and 40 unit length DOE and 120 O-ring
1
Cartridges must be ordered separately. Refer
to Filter Media.
2
See option section for modification required to
accept SOE cartridges.
255
13
SERIES FRP CHAMBERS
The Series 630 and 640 Bag Filter Chambers are de- a choice of cover closure; either the traditional swing
signed for ltering various process solutions where clar- bolt/tie rod with tee handles or screw top.
ication will extend operating life and improve quality.
As before the Series 630 and 640 Bag Filter Chambers
These chambers have been redesigned to make them feature non-metallic solution contact and are offered
easier to operate and more convenient to service. The in a choice of materials of construction to meet a wide
new design features a bottom inlet and bottom outlet variety of applications. The single bag design provides
which allows these chambers to be hard piped and al- lter area to 5.0 sq. ft. and micron retention Ratings of
lows the user to change bags without disconnecting 1 to 100.
any hoses or piping. Additionally the new design gives
50-100
MICRON
257
Series 630 & 640 bag lter chamber specications and ordering information C-307A
13
Chambers with choice of swing bolt/tie rod cover Pressure gauge with gauge guard standard on cham-
closure with tee handles or screw top cover closure. bers with tee handles. EPDM elastomers standard.
PVDF shell sealed to base. PVDF base and cover. KL630BFS-1-G3 78-1783K
KL SS tie rods with tee handles. PVDF vent plug. KL640BFS-1-G3 78-1784K
- -
For Viton elastomers change L to V in model Number and add V to Price Code Number
MAXIMUM HEIGHT
SURFACE SHIPPING
SERIES PORTS FLOW
AREA WEIGHT
NUMBER RATE A B
ft.2 m2 NPT GPM LPM in mm in mm lbs kg
630 3.5 .3 1 40 151 39.5 1003 36.6 930 38 17
640 5.0 5.0 1 40 151 49.5 1257 46.6 1184 50 23
The Series 1230 and 1250 Bag Filter Chambers are de- lizes multiple 4 anged bags which provides greater
signed for ltering various process solutions where clar- surface area for the same size chamber.
ication will extend operating life and improve quality. As before the Series 1230 and 1250 Bag Filter Cham-
These chambers have been redesigned to make them bers feature non-metallic solution contact and are of-
easier to operate and more convenient to service. The fered in a choice of materials of construction to meet
new design features a bottom inlet and bottom outlet, a wide variety of applications. The new design pro-
which allows these chambers to be hard, piped and vides lter area to 19.5 sq. ft. and micron retention
allows the user to change bags without disconnecting ratings of 1 to 100.
any hoses or piping. Additionally the new design uti-
50-100
MICRON
259
SERIES 1230 & 1250 BAG FILTER CHAMBER C-308
13
Chambers hold ve individual 4 anged bags. All reinforcing plate, 0-60 PSI pressure gauge with gauge
chambers have cover swing bolts with tee handles, guard, EPDM gaskets and drain plugs. All fasteners
stainless steel swing bolt bracket; FRP top and bottom are stainless steel.
PRICE CODE
DESCRIPTION MODEL NUMBER
NUMBER
PL1230BFS 1 - G3A 78-1733P
PL PVC shell. CPVC base and cover
PL1250BFS 1 - G3A 78-1735P
CL1230BFS 1 - G3A 78-1733C
CL CPVC shell, base and cover.
CL1250BFS 1 - G3A 78-1735C
Polypropylene shell. Glass reinforced PPL1230BFS 1 - G3A 78-1733PP
PPL polypropylene base and cover. PPL1250BFS 1 - G3A 78-1735PP
For Viton elastomers change L to V model Number and add V to Price Code Number
MAXIMUM HEIGHT
SURFACE SHIPPING
SERIES PORTS FLOW
AREA WEIGHT
NUMBER RATE C A
ft.2 m2 NPT GPM LPM in mm in mm lbs kg 'C'
1230 12.0 1.1 1 1/2 80 303 38.4 975 41.9 1064 100 45 'A'
1250 19.5 1.8 1 1/2 100 454 58.4 1483 61.9 1572 115 52
These disc filter chambers are designed for of organic removal. Some applications may allow
quality filtration of plating and other chemical solu- filtration without a media precoat. Chambers
tions. The large surface area with I.D. and O.D. edge include a drip pan to catch run-off liquid when
seals on all filter discs assures optimum performance servicing discs.
and clarity of solution being filtered. Disc filters may Disc chambers are serviced by lifting the cover
be used with a precoat of filter aid alone or with a and disc stack assembly from the chamber, facili-
mixture of filter aid and powdered carbon. Carbon tating a cleaner change-out and less solution loss
discs are also available and may be installed in than with other designs. No messy "floating" of the
total or in partial to accomplish the proper degree disc is required when changing the disc media.
50-100
MICRON
261
13
SOLIDS
NO. OF DIM.
AREA
DISCS 'C'
sq. ft.
1 1/2" INLET
15 31 20-15/16 2"
30 65 30-15/16
45 99 40-15/16
MAXIMUM C
PSI @ OPERATING
TEMP.
PVC CPVC 15/16" 15/16"
1 1/2" OUTLET
80 80 70F 1 1/2" INLET
75 75 100F
40 70 120F 1 1/2" DRAIN
3"
25 55 140F 3/4" EFFLUENT
1 5/8"
DRAIN
35 170F
30 200F
14 3/4"
The 'DR' filter chambers are designed for qual- The 'CR' chambers are designed for use with
ity filtration of plating and other chemical solutions. cartridges for applications where higher dirt holding
The high surface area with I.D. and O.D. edge seals capability is required. The internal cartridge assembly
of filter discs assures optimum performance and can hold cartridges of DOE / SOE or sleeve design
clarity of solution. and utilizes individual cartridge guides with screw
Disc filters can be used with a precoat of filter on caps for a positive cartridge seal. The cartridge
aid alone or with a mixture of filter aid and powdered assembly replaces the disc stack. All other specifi-
carbon for organic removal. Some applications may cations are the same as the 'DR' chambers.
allow filtration without a media precoat. Chambers
include complete set of polypropylene plates, drain
and vent connections.
13
CHAMBER SPECIFICATIONS
Series 'DR' / 'CR' filter chambers are carbon steel the three cover sizes. Tangent inlet is 3" flange, drain and
fabricated, then vulcanized rubber lined to provide years vent ports are 1" flanged. Bottom center outlet is 3" NPT
of trouble-free service. Exterior metal surfaces are primed which facilitates convenient direction of discharge piping.
and coated two part epoxy gray enamel. Swing bolt hard- Cover includes lift handles . Hoist lugs are provided on the
ware is stainless steel. Non-metallic internals are CPVC or two large models. Chamber includes mounting pads for
poly-propylene. Bottom half of the chamber is common for optional davit lift for cover.
G5 GAUGE
GUARD
8-3/16
CHAMBER LEGS ASS'Y (OPT.)
25/32 MOUNTING
HOLES
ON A 26- 7/8 D.B.C.
LIFTING
LUG
33-3/16
SWING
LIFTING BOLT
HANDLE 7-3/4 12-3/8 ASS'Y.
(14 REQ'D)
A* DRAIN
FLANGE
1" (150#)
14-1/4
42-1/8
27
TOP VIEW INLET
FLANGE 12-5/16
3" (150#) OUTLET 7
3" NPT
CARTRIDGE CHAMBER NO. OF AREA MAX. FLOW SHIPPING WT. PRICE CODE
MODEL CARTRIDGES Sq. Ft. Sq. m. GPM LPM Lbs. kg. NUMBER
CR1200 120 - 10" 420 39 660 300 78-1466
CR1800 180 - 10" 630 59 350 1320 760 345 78-1465
CR2400 240 - 10" 840 78 800 363 78-1464
DISC MICRON PRICE CODE NO. Pressure gauge 0-60 PSI mounted on
CPVC gauge guard with 78-0073
MODEL RATING Cellulose Polypropylene -G5
diaphragm and CPVC vent valve
** E5 x 24 5 78-1420 78-1460 Davit cover lift
** E10 x 24 10 78-1421 78-1461 Model __ R60-3 78-1602
** E20 x 24 20 78-1422 78-1462 __ R78-3 -D 78-1603
** E40 x 24 40 78-1423 78-1463 __ R105-3 78-1604
SERIES 'Y' filter chambers are made of carbon steel with vulcanized
rubber or Hypalon lining to provide non-metallic solution contact for use with
a wide range of chemical solutions. Corrosion resistance in each case is
limited to the materials used in construction, including all components. It
should be noted that corrosion resistance varies at different temperatures.
Consult Bulletin TC-101 and Sales Department.
These chambers are ideal for in-line applications or they can be used
with a pump and motor filtration system for various chemical applications.
Shown w/optional
davit cover lift
SCORES OF AP
PLICATIONS
HEAVY CONSTRUCTION
Units are of welded construction, 75 PSI design. Food prod
Optional: ASME code design and code stamp (75 and 150 PSI). ucts
Chemical so
EASY TO SERVICE lutions
Pharm
These filter chambers are specifically engineered and built for fast, easy aceuticals
servicing. Bottom separator plate is completely removable. All chambers Petro
-chemicals
have flanged inlet, outlet and vent. Photo
graphic ch
emicals
DESIGNED for "CHOICE" of FILTER MEDIA Indust
rial liquids
Standard chamber will accept double open end (DOE) depth, pleated, and gases
Water
membrane and carbon cartridges from sub-micron to 100 micron reten- treatment
tion. Cleanable sleeves designed for precoating are also available. Elect
roplating so
lutions
Clean
WIDE RANGE of SIZES ing solution
s
Units are available in a wide range of sizes from 24 filter cartridges to a
total of 445 cartridges to provide the highest flow rate with the largest
dirt holding capacity.
13
SERIES 'Y' chambers are designed for 75 PSI maximum op- optimum solids loading capacity or precoat cake thickener.
erating pressure, with removable bottom separator plate. They Depth, pleated, sleeve or carbon cartridges can be used in these
include stainless steel swing bolts and fasteners, with external chambers and are ordered separately. Chambers as described
steel surfaces painted two part epoxy gray. Models with "B" are for DOE (Double Open End) cartridges.
designation provide maximum space between filter media for
B Pressure gauge with
Chamber O.D. guard (optional) 3 legs at 120
Vent (optional)
Bottom seat
Tube guide TOP VIEW
Bottom separator
DETAIL LOCATIONS
plate with baffle
NOTE: Inlet and outlet connections are available
LEG HEIGHT D in optional sizes, locations and styles. Consult
Size 240 & 360 - 14" Filter
Sales Department.
Size 520 to 1750 - 15" Outlet "A"
Size B1800 to B4450 - 20" CARTRIDGES or SLEEVES REQUIRED
E to FILL FILTER CHAMBER4
DIMENSIONS ("E" w/rubber lining) SHIP. MODEL PREFIX LETTER FILTER CARTS. REQ'D CLEANABLE SLEEVES
MODEL A B C D E WEIGHT & PRICE CODE NO. Number of Solids Sleeves Total ADD
AND YR YH depth filter cap. req'd sur- PRICE
CHAMBER in. mm in. mm in. mm in. mm in. mm Lbs. kg. depth No. Lgth. face
RUBBER HYPALON cartridges area area CODE
SIZE
LINED STEEL LINED STEEL 10" 20" 30" Sq. ft. of in. Sq. ft. NO.
_240-2 32 813 350 159 78-0002 78-0036A 24 or 12 84 12 20 14.4 78-0201
_360-2 42 1067 375 170 78-0003 78-0037A 36 or 12 126 12 30 21.6 78-0202
_520-2 2 51 18 457 32 813 22 559 12 305 360 163 78-0004 78-0038A 52 or 26 182 26 20 31.2 78-0412
_780-2 42 1067 390 177 78-0005 78-0039A 78 or 26 273 26 30 46.8 78-0413
_B540-4 45 1143 600 272 78-0006 78-0040A 54 or 18 189 18 30 32.4 78-0414
_870-4 45 1143 650 295 78-0007 87 or 29 305 29 30 52.2 78-0415
78-0041A 18 + 18
800 363 90 or 315 18 50 54.0 78-0404
_B900-4 65 1651 78-0008 78-0042A 35 367
4 102 22 559 45 26 660 14.5 368 850 105 or 35 30 63.0 78-0405
_1050-4 1143 386 78-0009 78-0043A 29 + 29 508
145 or 29 50 87.0 78-0406
_1450-4 65 1651 900 408 78-0010 78-0044A 175 or 35 + 35 612 35 50 105.0 78-0407
_1750-4 65 1651 1000 454 78-0011 78-0045A
_B1800-6 180 or 36 + 36 630 36 50 108.0 78-0408
65 1651 32.6 829 18 1200 544 78-0012 78-0046A
6 152 28 711 457 300 or 60 + 60 1050 60 50 180.0 78-0409
_3000-6 65 1651 1400 635 78-0013 78-0047A
_B3000-8 65 1651 1500 680 78-0014 78-0048A 300 or 60 + 60 50 180.0 78-0409
8 203 32 813 65 35 889 20 508 1800 1050 60
_4450-8 1651 816 78-0015 78-0049A 445 or 89 + 89 1557 89 50 267.0 78-0411
_B4450-8 8 203 44 1113 65 1651 39 991 26 660 1950 885 78-0016 78-0050A 445 or 89 + 89 1557 89 50 267.0 78-0411
OPTIONAL
1
PRICE CODE NUMBER Not included when sleeve
ADD TO
DESCRIPTION assembly is ordered.
MODEL NO. 18" dia. 22" dia. 28" dia. 32" dia. 2
SOE cartridge seats are
Davit cover lift -D 78-0066 78-0066 78-0067 78-0068 optional.
75 PSI ASME code design - non stamped -75 78-1381 78-1382 78-1383 78-1384 3
Use of a tee pipe fitting on
150 PSI ASME code design - non stamped -150 78-0079 78-0080 78-0081 78-0082 inlet & outlet flange serves
as a drain.
ASME code stamp (75 & 150 PSI) -X 78-0084 4
Filter media must be ordered
Pressure gauge mounted on CPVC gauge guard with separately.
-G5 78-0073
diaphragm & CPVC valve assembly
For bulk or canister carbon 'Y'
222 "O"-ring cartridge seats for SOE chambers, see Bulletin M-305.
(Single Open End) cartridges 2 -2 add -2
SERIES 'YW' METAL 266
Stainless steel
SERFILCO Series 'YW' filter chambers are designed Chambers for use with salt water are typically
to meet the unique requirements of the municipal manufactured of rubber lined steel with non-metallic
and desalination markets. They provide high flow internal components, however all carbon steel or
rates to 13,000 GPM for pre-filtration ahead of stainless steel chambers are also available depend-
reverse osmosis membranes and are designed for ing on the application. All chambers are designed
use with either double open end or single open end and manufactured to ASME code with pressures to
filter cartridges. 300 psi if required.
CHAMBER CAPABILITIES
CHAMBER FLANGE NUMBER OF TOTAL NUMBER OF MAXIMUM INLET VELOCITY
MODEL 1
DIAMETER (in) SIZE (in) COLUMNS 10" CARTRIDGES2 FLOW (GPM) (ft/s)
YWR 4450-10 32 10 89 445 2225 9.1
YWR 5300-10 36 10 106 530 2650 10.8
YWR 7900-12 42 12 158 790 3950 11.2
YWR 10950-14 48 14 219 1095 5475 11.4
YWR 13500-16 54 16 270 1350 6750 10.8
YWR 16800-18 60 18 336 1680 8400 10.6
YWR 20800-20 66 20 416 2080 10400 10.6
YWR 26000-24 72 24 520 2600 13000 9.2
1.
Rubber lined steel chamber 2.
Using 50" length, 2 1/2" diameter cartridges
13
FOR FILTRATION AND PURIFICATION OF:
WATER / PHOTOGRAPHIC / SOLVENTS / CHEMICALS
PHARMACEUTICAL / OILS / WASTE TREATMENT
STAINLESS STEEL
M4S10- " NPT 1 78-1507
304 stainless steel,
M4S10-1 1" NPT 1 78-1508
304 stainless steel
M4S20- " NPT 2 78-1509
centering spring 250 PSI
M4S20-1 1" NPT 2 78-1510
Buna N
M4S30- " NPT 3 78-1511
shell gasket 1
M4S30-1 1" NPT 3 78-1512
M6S10- " NPT 1 78-1513
M6S20-1 316 stainless steel,
M6S10-1 1" NPT 1 78-1514
304 stainless steel
M6S20- " NPT 2 78-1515
centering spring 250 PSI
M6S20-1 1" NPT 2 78-1516
Buna N
M6S30- shell gasket 1 " NPT 3 78-1517
M6S30-1 1" NPT 3 78-1518
SS10-HP 316 stainless steel 750 PSI 1 78-0876
SS20-HP EPDM "O" ring 750 PSI 2 78-0877
" NPT
SS10VS- for fixed length 250 PSI 1 78-0878
SS10VS- SS20VS- cartridge 250 PSI 2 78-0880
1
Fiber gasket at vent, drain and center nut. Viton elastomers: Add -V to Model
and suffix V to Price Code No.
STAINLESS STEEL
MAXIMUM PORT NO. FILTER PRICE
MODEL MATERIAL PRESSURE SIZE CARTRIDGES CODE NO.
SS50(1)-2 304 stainless steel 5 78-0885
SS100(2)-2 w/mounting legs 100 PSI 2" MNPT 10 78-0886
SS150(3)-2 Buna N gasket 15 78-0887
Vent Cartridge
clearance (F)
8.4
2" NPT
A inlet Adjustable legs
B
3/4" NPT
C drain
D
2"NPT
4.6 REF
outlet
13
PROCESS WATER / CLEANERS
PARTS WASHERS / CHEMICALS
Carbon steel, 304 or 316 stainless
steel construction
Large capacity
448 cartridge
26.4 sq.ft multi-bag
150 PSI OR 300 PSI pressure rating
Swing bolt cover closure
Consult Sales Department for options
CARTRIDGE CHAMBERS
Model and Price Code Number shown for carbon steel construction.
- for 304 SS change first S in Model No. to 4SS and add S4 to Price Code No.
- for 316 SS change first S in Model No. to 6SS and add S6 to Price Code No.
For Viton elastomers, add -V to Model No. and V to Price Code No.
SINGLE 3-ROUND
and 6-ROUND
D 0o D 0o 1/4 PLUG
1/4 PLUG
1
1
270o 270o 90o
90o
4.0 6.0
IN IN Top
180o
Top 180o
view view
A B
A B 1/4 D.P. port
w/plug 1.4 D.P. port
C
w/plug
5.8 4.3
5.8 4.3
1/2 drain 1 drain
w/plug w/plug
1.5
1.5 Bottom
OUT view OUT Bottom view
271
13
FEATURES:
Carbon steel or stainless steel construction
EPDM elastomers standard (Viton optional)
Bearing assisted davit assembly
Swing bolt cover closure with eye nuts
150 PSI pressure rating
316 SS internals
Differential, drain and vent ports
Heavy duty support legs
2-part epoxy finish on carbon steel
Model and Price Code Number shown for carbon steel construction. DIA. A E F G
- for 304 SS change first S in Model No. to 4SS
12" 11.0 9.2 10.0
and add S4 to Price Code No.
- for 316 SS change first S in Model No. to 6SS and 16" 13.0 10.8 11.5
add S6 to Price Code No. 18" 14.0 11.8 12.0
For Viton elastomers add -V to Model No.
and V to Price Code No. 24" 17.0 14.8 16.5
30" 20.0 17.8 20.8
36" 25.0 20.8 24.7
272
C-207C
SERIES 'K' METAL FILTER CHAMBERS - Bag
13
BAG CHAMBERS
FEATURES:
Carbon steel or stainless steel construction
EPDM elastomers standard (Viton optional)
Swing bolt cover closure with eye nuts
300 PSI pressure rating (4" dia.)
150 PSI pressure rating (6" & 8" dia.)
316 SS strainer basket
Differential, drain and vent ports
Adjustable support legs
2-part epoxy paint on carbon steel
O-ring seal
Bag seal
ring Bail handle
Contaminated
liquid
Basket
O-ring seal
Clean
Inlet liquid
Single Bag
Chambers 316SS strainer
4", 6", 8" Dia. basket
Outlet
Housing
13
SPECIFICATIONS
Housing lid has a 3-bolt swing closure with a vent satin finish. Basket material is constructed of 316
port. Connections are as noted with standard side stainless steel with 9/64" perforations to act as a
inlet and bottom outlet. strainer or to accept a liquid filter bag. Basket for
Housing is supplied with two differential pressure KBS6 and KBS8 chamber seats onto an "O"-ring in
ports to measure the differential pressure across the basket support. Adjustable tripod leg assembly
the filter bag. A two-part epoxy finish is applied on is supplied with housing.
the carbon steel vessels to maximize the life of the KBS4 chamber is rated at 300 PSI. KBS6 and
housing; stainless steel vessels are supplied with a KBS8 chambers are rated at 150 PSI.
SURFACE DIA.
MODEL BASKET CONN. PRICE
AREA A
NUMBER1, 2 SIZE (in) SIZE CODE NO. 1, 2
(sq. ft.) (in)
KBS406-1 0.5 4.5 3.9 x 6 (#3) 1" NPT 78-1800
KBS412-1 1.0 4.5 3.9 x 12 (#4) 1" NPT 78-1801
KBS618-11/2 2.0 6.6 5 x 18 (#8) 11/2" NPT 78-1802
KBS630-11/2 3.4 6.6 5 x 30 (#9) 11/2" NPT 78-1803
KBS815-2 2.3 8.6 6.7 x 15 (#1) 2" NPT 78-1804
KBS830-2 4.4 8.6 6.7 x 30 (#2) 2" NPT 78-1805
Model and Price Code Number shown for carbon steel construction.
- for 304 SS change S in Model No. to 4SS and add S4 to Price Code No.
- for 316 SS change S in Model No. to 6SS and add S6 to Price Code No.
For Viton elastomers, add -V to Model No. and V to Price Code No.
B Vent
Model and Price Code Number shown for carbon steel construction. Bearing
F
- for 304 SS change S in Model No. to 4SS
and add S4 to Price Code No.
- for 316 SS change S in Model No. to 6SS and 1/2 D.P. port/vent
add S6 to Price Code No.
For Viton elastomers, add -V to Model No. and V to Price Code No. Bearing
Basket size 6.7" x 30" (#2)
1/4 D.P. port
D.P. A
C
Port/vent
B
Inlet Outlet
D 1NPT
drain
E
Top view G
1dia. bolt hole
275
13
TWIN CAPACITY BAG CHAMBER
FEATURES:
2 Model KBS830 housings with common
connections
Increased flow rates
Lower differential pressure
Carbon steel or stainless steel construction
Model and Price Code Number shown for carbon steel construction.
- for 304 SS change S in Model No. to 4SS
and add S4 to Price Code No.
- for 316 SS change S in Model No. to 6SS and
add S6 to Price Code No.
For Viton elastomers, add -V to Model No. and V to Price Code No.
FEATURES:
Carbon steel or 304 stainless steel
construction
100 PSI pressure rating
Low pressure drop with #12 size bag
Strainer basket
Side and bottom outlets
Model and Price Code Number shown for carbon steel construction.
- for 304 SS change S in Model No. to 4SS
and add S4 to Price Code No.
For Viton elastomers, add -V to Model No. and V to Price Code No.
Basket size 8" x 30" (#12)
276
13
ECONOMICAL, IN-LINE
FILTER FOR:
HYDRAULIC / LUBE / CUTTING
MINERAL AND FUEL OILS
RENEW OIL
Extend equipment and machinery life
Minimize oil disposal costs
ONE AND TWO CARTRIDGE MODELS
Carbon steel with Buna-N gasket
OPERATING PRESSURE 75 PSI MAX.
MODEL
S1(718)-1 OPERATING TEMPERATURE 240F MAX
SAFETY COVER PRESSURE RELIEF
WALL MOUNT BRACKET INCLUDED
Floor mounting legs optional
ACCEPTS 4" x 18" and 7" X 18" CARTRIDGES
4" x 18" Maxi-Wind cotton and polypropylene
7" x 18" pleated paper, cotton, Fuller's earth
8 5/8" Dia.
" NPT
Vent plug 5 /8"
5
E
Filter chamber
11" Dia. with optional
mounting legs.
2"
C
Center
Inlet
post
D dia.
10
SU
1" NPT 0 0S 500 S
SU
10 100 SSU
Drain plug
C 0 10 20 30
2"
Outlet
MODEL OIL VOLUME MAX. FLOW INLET & OUTLET DIMENSIONS (inches) SHIPPING WT. PRICE CODE
NUMBER GALS. GPM NPT LBS. NUMBER
A B C D E
S1(718)-1 5 30 1" 17 24 3/4 1 1 5/16 5 5/16 40 79-0901 1
S2(718)-1 9.5 60 1 1/2" 35 42 3/4 1 1/2 1 11/16 5 7/8 60 79-0901 2
ORDER FILTER CARTRIDGES SEPARATELY
OPTIONAL
COVER GASKET, VITON 22-0626 1
MOUNTING LEGS 78-0888
ADMIRAL 279
14
INSTALLATION
Series 'EO'
pump
Admiral ltration systems are available for a wide range
of tank sizes from laboratory scale to large production
requirements. Corrosion resistance is achieved by the
use of a variety of engineering plastics such as CPVC,
PVC, PP and PVDF with stainless steel external parts.
NOTE:
Hose, pipe and ttings required to connect the pump
to the lter chamber and plumb to the tank must be
ordered separately. Request Bulletin A-213.
TYPICAL INSTALLATIONS
PUMP AND FILTER IN TANK PUMP AND FILTER OUT OF TANK PUMP IN TANK AND
FILTER OUT OF TANK
280
PERFORMANCE
14
SPECIFICATIONS
To order, use System No.
1
For PVC chamber, change rst C to P in System Number. 2
Motors less than 1.0 HP are 115-230/1/50-60, TEFC.
For polypropylene system, change first C to PP in Sys- Motors 1.0 HP and above are 230-460/3/60 or 190-380-
tem Number. 415/3/50, TEFC.
For PVDF system consult Sales Department. 3
For BSP, metric socket, or flange connections, consult
Sales Dept.
281
SPECIFICATIONS
To order, use System No.
14
PUMP SYSTEM FILTER CHAMBER
SYSTEM MOTOR2 IN / OUT 3 WEIGHT
SERIES
NUMBER GPH LPH SERIES CARTRIDGES HP (In. NPT) Lbs.
& CURVE
CG12EO515 12 - 10" 160
EO5 3,600 11,300 G 1.5 11/2 x 11/2
CG24EO515 12 - 20" 170
CG24EH220 12 - 20" 205
EH2 4,800 15,000 G 2.0 2 x 11/2
CG36EH220 12 - 30" 215
CG24EH330 12 - 20" 225
CG36EH330 EH3 5,400 16,800 G 12 - 30" 3.0 2 x 11/2 235
CG48EH330 12 - 40" 245
CG36EH450 12 - 30" 235
CG48EH450 EH4 6,600 19,600 G 12 - 40" 5.0 2 x 11/2 245
CG60EH450 12 - 20" + 12 - 30" 255
CG48EH675 12 - 40" 255
EH6 7,000 21,800 G 7.5 2x2
CG60EH675 12 - 20" + 12 - 30" 265
1
For PVC chamber, change rst C to P in System Number. 2
Motors are 230-460/3/60 or 190-380-415/3/50, TEFC.
For polypropylene system, change first C to PP in System 3
For BSP, metric socket, or flange connections, consult
Number. Sales Dept.
For PVDF system consult Sales Department.
ACCESSORIES
ADD TO
VITON / HYPALON ELASTOMERS
SYSTEM NO.
Filter chamber and pump V
NOTE: 'GC' chambers use Hypalon gaskets.
PRICE PRICE
DESCRIPTION DESCRIPTION
CODE NO CODE NO.
MOTOR STARTER - NEMA 4X Watertight push button CARBON PURIFICATION CHAMBER
115 - 230V/1/50-60 O-MS1P with ow control valve, hose & drain CPVC PVC
230 - 460V/3/50-60 O-MS3P Order carbon media from Bulletin M-305
MEDIA SELECTION
Cartridges for filtration For purification
Designed for off-the floor, in-tank mounting Wound depth Carbon cartridges
where floor space is not available.Convenient Spun depth Mini-canister for
cartridge replacement. Pleated carbon or resin
283
GENERAL SPECIFICATIONS
The Sub-Admiral In-Tank Filtration Systems feature pump motors that are chemical duty design.
feature a pump with a cantilevered, sleeved stainless Eductors are molded of polypropylene and threaded
14
steel shaft which eliminates bearings and seals, result- to the pump discharge port. They provide 5 gallons of
ing in a pump that can run dry without damage. A vapor clean agitation for each gallon discharged from the
seal between the rotating shaft and the support col- pump.
umn helps protect the motor. The mounting plate has Series 'ES' models include adjustable non-
the pump mounted off-center to allow clearance when metallic 'C' clamp for securing unit to tank and 12"
mounting to the tank flange. suction extension to convert system to transfer pump.
Standard models constructed of CPVC or polypro- Series 'ECS' and 'EHS' have optional suction pipe
pylene, for non-metallic solution contact. Most models extensions.
INPUT
EACH GALLON OF
PRESSURE LIQUID
PERFORMANCE
WITH EDUCTOR WITHOUT EDUCTOR
HORSE- DISCHARGE
SERIES POWER NPT FILTER GPH CARTS.* AGIT.GPH FILTER GPH CARTS.*
'ES' 1/8 3/4" 600 1 - 10" 3,000 960 1 - 20"
1/3 720 2 - 20" 3,600 1,320 2 - 20"
'ECS' 3/4"
3/4 900 2 - 20" 4,500 2,160 2 - 20"
1 1-1/2" 1,920 3 - 20" 9,600 4,700 3 - 20"
'EHS' 1-1/2 2,400 3 - 20" 12.00 6,000 3 - 30"
3 1-1/2" 3.050 3 - 20" 15,300
Not Recommended
5 3,900 19,500
3 - 30"
* Recommended minimum length. Longer cartridges will extend operating life.
284
F.O.B. Northbrook, Illinois Registered trademarks: Corzan - B.F. Goodrich Co.; Viton - DuPont Dow Elastomers
ADMIRAL 'EL' 285
14
CPVC or PVDF with EPDM elastomers.
Viton elastomers optional.
Runs dry without damage
Compact, lightweight
For 10", 20" or 30" cartridge lengths
For in-tank or out-of-tank mounting
BENEFITS
Efcient pump and pressurized lter chamber
provides longer intervals of continuous high
ow than any suction style lter
Reduce scrap, rework, chemical consumption,
tank maintenance improve product quality
Accepts a wide variety of media string
wound, melt blown, pleated, carbon, sleeves
or canisters, or a combination thereof
Easy media change unit does not have to
be removed from the tank no tools are
required
SPECIFICATIONS
SYSTEM:
ADMIRAL 'EL' ltration systems consist of a verti- cover also includes a handy vent valve for purging air
cal, dry-run capable pump and a single column lter from the chamber.
chamber for a 10", 20" or 30" lter cartridge. The pump PUMP:
and lter are mounted in a compact conguration us- The rugged Series 'E' is a tough, all machined
ing a common mounting plate and union connection pump designed for years of trouble-free operation.
between the pump outlet and lter inlet. This pump is constructed of either polypropylene,
FILTER: CPVC or PVDF and features a cantilevered, sleeved
The lter is industry proven for ease of service stainless steel shaft which eliminates bearings and
and reliability. The Series 'L' lter chamber will ac- seals, resulting in a pump that can run dry with-
commodate a wide variety of lter media including out damage. The pump features a TFE vapor seal
string wound, pleated, melt blown, carbon, cleanable between the rotating shaft and the support column
sleeves or reusable canister. This rugged chamber which protects the motor. The compound impeller
features totally non-metallic solution contact and is prevents liquid from rising in the column, even at
constructed of either PVC with a translucent shell, maximum TDH, while the semi-enclosed bottom
polypropylene, CPVC or PVDF. The thumb screw impeller provides efcient ow performance at low
cover closure with "O"-ring ensures a proper seal and horsepower. Motors are 115-230V/1/50-60 Hz, TEFC
requires no tools for cartridge changing. The chamber with 8 ft. cord and 3-prong molded plug.
SERFILCO worldwide leader in service, dependability and design for over 40 years!
286
* See ow curve 1
Order lter media separately. Refer to Bulletin M-109.
ADD TO
OPTIONAL
SYSTEM NO.
Viton elastomers on lter V
chamber and pump
TOP VIEW
ADMIRAL 'EOS' 287
14
Non-metallic solution contact
Polypropylene, CPVC or PVDF with EPDM
elastomers. Viton elastomers optional.
Runs dry without damage
High filter surface area
3 20", 30" or 40" cartridges
Compact package
Designed for reservoir installation
Economical OEM replacement
BENEFITS
Improve finish goods quality, eliminate scrap
and rework
Reduce chemical consumption by
maintaining solution quality
Minimize downtime and maintenance with
dry-run capable Series 'EO' pump and high
surface area Series 'S' chamber
Higher continuous flow and filter area than
competitive systems
Easy media change no tools required
SPECIFICATIONS PUMP:
The Series 'EO' pump benefits from proven design
SYSTEM: features gained through over 40 years of experience in
ADMIRAL 'EOS' filtration systems consist of a developing chemically resistant vertical pumps.
vertical, dry-run capable pump, and a three column
The unique design of this pump includes a fully
filter chamber for 3 20", 30" or 40" filter cartridges.
sleeved stainless steel shaft threaded into a chemical duty
The pump includes a suction strainer and is mounted with
motor. This eliminates weak shaft connections, pump
the chamber in a compact configuration using a common
bearings, spindles, bushings and liners, resulting in
mounting plate. Systems are available in polypropylene,
a chemical duty pump which can run dry indefinitely,
CPVC or PVDF.
providing years of trouble-free service.
FILTER: A labyrinth and a TFE vapor seal between the
Industry proven for ease of service and reliability, the rotating shaft and the support column protect the motor.
Series 'S' filter chamber will accommodate a variety of The compound impeller prevents liquid from rising in the
filter media including string wound, pleated, melt-blown column, even at maximum TDH, while the fully enclosed
or carbon cartridges. The ruggedly constructed chamber bottom impeller provides efficient flow performance at
features a low pressure drop for long intervals of continu- low horsepower.
ous high flow. The chamber includes a swing bolt cover All models are injection molded of polypropylene,
closure with 'T'-handles, so no tools are required and CPVC or 100% pure PVDF. The stainless steel shaft
cartridge changing is quick and convenient. Also in- is fully sleeved with the same material from which the
cluded is a 0 - 30 psi gauge with guard and vent plug. The pump is constructed. Fasteners are stainless steel. The
chamber features totally non-metallic solution contact chemical duty motor has a stainless steel nameplate
and stainless steel external hardware. and is dual range 50 and 60 Hz.
288
DIMENSIONS (Inches)
MODEL
A B C D E F G* H J K L M N P Q R CONNECTIONS
EOS 1 & 3 11 5 20 4 4 5 2 5/16 8 5/16 FNPT x 1" FNPT
25 7/8 12 1/8 3 5/8 9 13 3/16 6 5/ 1 1 1" 1" FNPT x 1" FNPT
EOS 4 & 5 12 7 22 5 5 3/8 5 3/8 16
8 sq.
* 357/8 for 9 cartridge models, 457/8 for 12 cartridge models.
D
B
G
A
ADD TO
OPTIONAL E
SYSTEM NO. H L
F
FEATURES
14
Flow rates from 5,800 to 10,000 GPH
Non-metallic solution contact
CPVC with EPDM elastomers
Viton elastomers optional
Runs dry without damage
High filter surface area
6-20", 30" or 40" cartridges
Handles temperatures to 180F
(See a chemical resistance chart)
Compact package
Designed for reservoir installation
Economical OEM replacement
BENEFITS
Improve finished goods quality, eliminate
scrap and rework
Reduce chemical consumption by
maintaining solution quality
Minimize downtime and maintenance with
dry-run 'EH' pump
Higher continuous flow and filter area than
original equipment systems
Easy cartridge change no tools required
SPECIFICATIONS
SYSTEM: FILTER:
ADMIRAL 'EHJ' filtration systems consist of Innovative design with oversized inlet and
a CPVC pump and filter chamber, assembled outlet allows extended intervals of high flow
on a 2-piece modular PVC mounting plate. The operation with minimal pressure drop. The
mounting plate is joined with a rabbet joint and chamber is constructed of CPVC with EPDM
secured with 316 stainless steel hardware. The elastomers and is available with 6 - 20", 30" or
pump discharge and filter inlet are connected 40" cartridge capacity. Chamber includes swing
by a union fitting. This arrangement allows simpli- bolt cover closure with 'T'-handles, therefore, no
fied installation and convenient pump removal for tools are required for easy cartridge changing.
reservoir or pump maintenance. The standard Also included is a 0 - 60 psi gauge with guard as-
mounting plate is 22" x 12" overall. Custom plates sembly and a vent valve assembly designed to
are available. direct vent mist back to the reservoir. Chamber
features totally non-metallic solution contact and
stainless steel external hardware.
290
PUMP: 3-5/8"
4"
13-3/16" 4-1/4"
1" 2-1/4"
12"
22"
DIMENSIONS
MEDIA HEIGHT
LENGTH A
20" 18-5/8"
30" 28-5/8"
40" 38-5/8"
14
Open bag filters are ideal for applications
where quick change reusability of a gravity fil-
ter is desired. The filter bags are attached to a
manifold with cam-lock quick-disconnect cou-
plings for minimal downtime when servicing
and they can be repeatedly washed and reused
for fast, long-lasting payback on the cost of their
installation. Bag filters are available in CPVC
or PVDF materials and single or multiple bag
assemblies.
Bags are available in retention ratings from
coarse filtration at 100 micron to fine filtration at
1 micron.
1
To order PVDF system, change C to K in System Num- specifications. Order bags separately. Twin bag assemblies
ber. CPVC system includes quick-connect coupling, 6 ft. vinyl include two CPVC ball valves.
wire reinforced hose 2, pump and motor and bag assembly.
Hose is not included with PVDF systems which require hard 2
CAUTION: Do not use vinyl hose when system is to be used
piping. All motors are 1-phase TEFC, except for 1.0 HP, which at 150F (66C) or higher. System suction and discharge
is 3-phase. The 1-phase motors include 8 ft. of 3-wire cord and should be hard piped. Refer to Bulletin A-213 for installation
plug, wired for 115 volt operation unless otherwise requested. ttings.
Consult pump bulletins P-312 and P-300 for additional pump
292
INLET INLET
NPT NPT
14
C49BF-" C49BFx2-"
C716BF-" C716BFx2-"
1
Includes quick-connect coupling, mounting bracket, piping 3
Order bags separately from chart below.
and pipe ttings. Does not include pump and motor. Twin bag assemblies include two CPVC ball valves.
NOTE: PVDF assembly requires hard piping.
2
To order PVDF assembly
change C to K in Model Number and add K to Price Code No.
15
1/12 HP magnetic
drive pump
of construction materials allows use with most liquids,
345 GPH including harsh chemicals at elevated temperatures.
To order, select:
Seal-less Magnetic-Coupled Pump
Systems utilize Series 'A' magnetic- coupled pumps which
provide protection from vapor and liquid leaks. Pumps
available in a variety of engineering grade plastics to
suit chemistry and temperature, including polypropylene,
CPVC (Corzan) and PVDF (Kynar ).
then select:
'ET' System Filter Chamber for solids holding capacity*
CLE1A6
1-10" cartridge Constructed of clear PVC, polypropylene, CPVC or PVDF.
lter chamber Standard elastomers are EPDM (Viton with PVDF).
1/12 HP magnetic Chambers accept depth wound, pleated, cleanable sleeve,
drive pump and carbon cartridges. Chamber allows for simultaneous
345 GPH
filtration and purification by using carbon cartridges.
Separate purification chamber with flow control valve
available. See Options on next page.
LABMASTER 'ET'
Designed for off-the-oor, Edge-of-Tank mounting where
oor space is not available. Convenient cartridge replace-
ment. Accepts full range of depth wound and carbon
cartridges.
System Optional:
PCL1AC
1-10" cartridge Carbon Purication
lter chamber Purication is accomplished by using replaceable carbon
1/12 HP magnetic
drive pump
cartridges or rellable bulk granular carbon Mini-Canister.
Optional P1CM Flow of ltered solution is selectively diverted through carbon
carbon chamber chamber with a 3-way valve.
345 GPH
* Select a system which will provide 3.5 - 7.0 square ft. of solids
holding area per 50 gallons of solution. Flow rate should be 2 - 10
tank turnovers per hour, depending on clarity desired. Coarse
media and high ows are desirable for high dirt load applications.
Increasing the number of cartridges reduces solution ow per
cartridge, improves efciency and reduces cartridge consumption.
It is desirable to choose a system with chamber height above the
solution level to eliminate the need to re-prime after each lter
media change.
294
PCL Polypropylene pump, clear PVC chamber, CL CPVC pump and lter chamber, temp. to 195F *
temp. to 140F * Systems for nickel sulfamate, acid copper, copper
Systems for mild acid (non-uoride) and alkalies cyanide, zinc chloride, most uoborate baths and high
15
LABMASTER SYSTEM NO. 'ET' SYSTEM NO. FLOW SOLIDS DIMS.' SHIPPING
RATE MEDIA 2 AREA L xW x H WEIGHT
PCL PPL CL KL PCL CL (U.S. GPH) Sq. Ft. Inches Lbs.
PCL.4A6 CL.4A6 PCLE.4A6 CLE.4A6 240 1 - 4" 1.4 10 x 8 x 15 14
PCL.6A6 CL.6A6 300 1 - 6" 2.1 10 x 8 x 17 18
PCL1A6 PPL1A6 CL1A6 KL1A6 PCLE1A6 CLE1A6 345 1 - 10" 3.5 10 x 8 x 21 23
PCL2A6 PPL2A6 CL2A6 KL2A6 PCLE2A6 CLE2A6 345 2 - 10" 7.0 10 x 8 x 31 30
PCL3A6 PPL3A6 CL3A6 KL3A6 PCLE3A6 CLE3A6 345 3 - 10" 10.5 10 x 8 x 41 37
CL4A6 345 4 - 10" 14.0 10 x 8 x 51 42
OPTIONAL
15
electronics industry and in precious metal
plating, as well as for laboratory and pilot plant
runs.
Featuring SERFILCO's new, non-metallic,
leak-proof Series 'X' magnetic coupled pumps
and industry proven Series 'L' lter chambers,
these systems provide high ow and high turnover
rates, assuring continuous particle removal. Lab-
master 'LX' systems are available with or without a
carbon or resin purication chamber.
Seal-less magnetic drive pumps
Labmaster 'LX' ltration systems feature highly
efcient seal-less magnetic coupled pumps for
total solution containment and reliable perfor-
mance to 1.3 S.G. The pumps are available in
polypropylene or PVDF.
Filter chamber
Constructed of clear PVC, CPVC, polypropylene
or PVDF to ensure chemical and temperature
compatibility in a wide range of applications.
The standard chamber accepts double open end
(DOE) depth wound, pleated, melt blown, clean-
able sleeve and carbon cartridges. A 222 "O"-ring
seat for single open end (SOE) cartridges is
optional.
Simple carbon or resin treatment
The systems are also available with optional
purication chambers in polypropylene, PVC or
CPVC with reusable ABS canister offering a
low-cost, but effective method of continuously or
periodically removing organic impurities from
plating baths and other chemical solutions.
296
SPECIFICATIONS
CAUTION: Do not use vinyl hose when system is to be used at 150F (66C) or higher.
PCL Polypropylene pump, clear PVC chamber* CL Polypropylene pump and CPVC filter chamber*
Systems for mild acid (non-uoride) and alkalies Systems for nickel sulfamate, acid copper, copper
including electroless copper and gold. cyanide, zinc chloride and most uoborate baths
PPL Polypropylene pump and lter chamber* KL PVDF pump and lter chamber*
Systems for nickel sulfamate, acid copper, copper Systems for electroless nickel and nickel acetate seal.
cyanide, and zinc chloride.
* Consult a chemical resistance guide to conrm material /solution compatibility.
PERFORMANCE
Realistic system ow
297
15
PCL2X50 PPL2X50 CL2X50 KL2X50 1 - 20" X50 1/15 465 hose 30
barb
PCL3X50 PPL3X50 CL3X50 KL3X50 1 - 30" 35
PCL1X100 PPL1X100 CL1X100 KL1X100 1 - 10" 3/4" 25
PCL2X100 PPL2X100 CL2X100 KL2X100 1 - 20" X100 1/10 600 hose 30
barb
PCL3X100 PPL3X100 CL3X100 KL3X100 1 - 30" 35
1 3
PVDF systems have " NPT connections. Standard motors are 100-110V/1/50-60 with 6 ft. cord
2
Order lter media separately and 60 Hz plug. Optional 230V/1/50-60 motor available.
4
U.S. GPH @ 60 Hz, see ow curve.
ACCESSORIES
ADD TO
DESCRIPTION SYSTEM NO.
Viton elastomers on lter V
chamber and pump
Optional motor
-5
230V/1/50-60
5
Order carbon media from Bulletin M-305
298
DIMENSIONS
SYSTEM NO. A B
1 X 40 21"
2 X 40 31"
3"
3 X 40 41"
4 X 40 51"
1 X 50 21"
2 X 50 31"
4"
3 X 50 41"
4 X 50 51"
15
1 X 100 21"
2 X 100 31"
4"
3 X 100 41"
4 X 100 51"
LABMASTER 'LX'
FILTRATION SYSTEMS
with OPTIONAL CARBON
PURIFICATION CHAMBER
SPACE-SAVER 299
15
System
and extremely simple to operate. Choice of construc-
CS9D6 tion materials allows use with most liquids, including
3-30" cartridge harsh chemicals at elevated temperatures.
filter chamber
HP magnetic To order, select:
drive pump
1200 GPH Seal-less Magnetic-Coupled Pump
Systems may be selected with magnetic-coupled pumps which provide
protection from vapor and liquid leaks. Pumps available in a variety of
engineering grade plastics to suit chemistry and temperature, including
polypropylene, Ryton, CPVC (Corzan ) and PVDF (Kynar).
or select
Single or Double Seal Pumps
Systems with mechanical seals may be selected whenever excessive
abrasives or ferrous metal particulate are present. Double mechanical
seals are recommended for high temperature and electroless solutions.
Pumps available in CPVC or PVDF feature carbon ceramic seal faces and
Viton elastomers. Noryl 'G' pump is self-priming and features silicon
graphite seal faces with Viton elastomers.
then select
Filter Chamber for solids holding capacity*
Constructed of ABS/acrylic, PVC, polypropylene, CPVC or PVDF. Stan-
dard elastomers are EPDM (Viton with PVDF). Chambers accept depth
wound, pleated, cleanable sleeve, and carbon cartridges. System may
also be ordered for use with cleanable bags. Chamber allows for simul-
System
PPSH9D7 taneous filtration and purification by using carbon cartridges. Separate
3-30" cartridge purification chamber with flow control valve available.
filter chamber
HP magnetic * Select a system which will provide 3.5 - 7.0 square ft. of
drive pump solids holding area per 50 gallons of solution. Flow rate should
2400 GPH
be 2-10 tank turnovers per hour, depending on clarity desired.
Coarse media and high flows are desirable for high dirt load
applications. Increasing the number of cartridges reduces
solution flow per cartridge, improves efficiency and reduces
cartridge consumption. It is desirable to choose a system with
chamber height above the solution level to eliminate the need
to re-prime after each filter media change.
15
NUMBER GPH @ 60Hz PSI Sq. ft. CHAMBER CONN. Inches Lbs.
1200 GPH
CS6HC103 1200 12 3 - 20" 21.0 16 x 13 x 40 56
CS9HC103 1200 12 3 - 30" 31.5 HC, 1/3, S 1" 16 x 13 x 50 66
CS12HC103 1200 12 3 - 40" 42.0 16 x 13 x 60 76
CS9HC208 1800 20 3 - 30" 31.5 16 x 13 x 50 120
HC, 3/4, S 1"
CS12HC208 1800 20 3 - 40" 42.0 16 x 13 x 60 140
CSH9HK310 2400 18 3 - 30" 31.5 1"x 16 x 13 x 50 125
HK, 1, S
CSH12HK310 2400 18 3 - 40" 42.0 1" 16 x 13 x 60 135
CSH9HK415 3000 23 3 - 30" 31.5 16 x 13 x 50 130
1"x
CSH12HK415 3000 23 3 - 40" 42.0 HK, 1-1/2, S 16 x 13 x 60 140
1"
CSH15HK415 3000 23 3 - 50" 52.5 16 x 13 x 70 150
IMPORTANT:
1
Filter media is ordered separately. Refer to Bulletin M-109
(cartridges), M-108 (sleeves) or M-305 (carbon). 4
CAUTION: Do not use vinyl hose when
Listed system includes CPVC chamber. system is to be used at 150F (66C)
2
To order system with PVC chamber -
or higher. System suction and discharge
Change C to P in System No.
2A
To order system with polypropylene chamber - should be hard piped. Refer to Bulletin A-213 for
Change C to PP in System No. installation fittings.
3
To order pump with double mechanical seal - * PVC chamber not available.
Change HC to HCD or HK to HKD in System No. Consists of three 20" and three 30" cartridges.
302
IMPORTANT: 1
Filter media is ordered separately. Refer to Bulletin C-301 for bag media.
2
Listed system includes CPVC chamber: To order system with PVC chamber - Change C to P in System No.
3
To order pump with double mechanical seal - Change HC to HCD in System No.
OPTIONAL
PRICE PRICE
DESCRIPTION CODE NO. DESCRIPTION CODE NO.
MOTOR STARTERS - NEMA 4X Watertight push button CARBON PURIFICATION CHAMBER
with flow control valve, hose & drain CPVC PP
115 - 230V/1/50-60 O-MS1P
Order carbon media from Bulletin M-305
230 - 460V/3/50-60 O-MS3P
Includes ABS mini-canister / CPVC chamber for
Add -S to Motor Starter PCN when ordering motor starter
2.1 lbs. granular carbon 20" canister O-C2CM -
for use with DRI-STOP Pump Protector. i. e. O-MS1P-S
3.2 lbs. granular carbon 30" canister O-C3CM -
Important: Specify operating voltage.
Includes PVC canister / CPVC chamber for
DRI-STOP PUMP PROTECTOR 7.5 lbs. granular carbon 5" x 28" canister O-1528C -
(PVC canister / PVC chamber- O-1528)
DRI-STOP 2R for use with double mechanical O-2DS2R
seal pumps. Includes CPVC or polypropylene chamber for
1.2 lbs 20" carbon cartridge O-C2CC O-P2CC
DRI-STOP 3 for use with magnetic drive or O-DS3C
1.8 lbs 30" carbon cartridge O-C3CC O-P3CC
single mechanical seal pumps. 3.0 lbs 5" x 28" Maxi-carb cartridge O-1528M O-PP1528M
VITON ELASTOMERS
OPERATING VOLTAGE
Series 'L' chambers O-SV
Series 'S' chambers 1 horsepower & above - Single phase O-1PH
O-LV Under 1 horsepower - Three phase O-3PH
MECHANICAL SEALS for HC & HK PUMPS
M1 EPDM / ceramic O-M1 50 Hz OPERATION
M2 Viton / ceramic Standard Single phase @ 50 Hz O-150H
PRIMING CHAMBER Three phase @ 50 Hz O-350H
Pump Series B, HC & D H.P. - Polypropylene O-PC4 Registered trademarks:
Pump Series HK & D H.P. - Noryl / PVC O-PC6 Kynar - Atochem; Corzan - B. F. Goodrich Co.; Noryl - General Electric;
Viton - DuPont Dow Elastomers; Ryton - Phillips Chemical
SPACE-SAVER 'SX' 303
15
duction in the electronics industry and in precious
metal plating.
SPECIFICATIONS
PS PVC chamber with polypropylene pump * CS CPVC chamber and polypropylene pump *
PPS Polypropylene chamber and pump * KS PVDF chamber and ETFE pump *
PERFORMANCE
15
PS12X200 PPS12X200 CS12X200 KS12X200 3 - 40" 55
PS3X250 PPS3X250 CS3X250 KS3X250 3 - 10" 45
PS6X250 PPS6X250 CS6X250 KS6X250 3 - 20" 50
X250 1/3 1200 1" NPT
PS9X250 PPS9X250 CS9X250 KS9X250 3 - 30" 55
PS12X250 PPS12X250 CS12X250 KS12X250 3 - 40" 60
1
Order lter media separately.
2
Standard motors are 100-110V/1/50-60 with 6 ft. cord & 60 Hz plug.
Optional 230V/1/50-60 motor available.
3
U.S. GPH @ 60 Hz, see ow curve.
ACCESSORIES
ADD TO
DESCRIPTION SYSTEM NO.
Viton elastomers on lter
V
chamber and pump
Optional motor
-5
230V/1/50-60
4
Order carbon media from Bulletin M-305
306
DIMENSIONS
15
OUT LET
A
10 3/ 4
4 1/ 4 16 1 / 2
5 1/ 2
12
SYSTEM SIZE A
SPACE-SAVER 'SX'
FILTRATION SYSTEMS
with OPTIONAL CARBON
PURIFICATION CHAMBER
SPACE-SAVER 'SM' 307
15
PRINTED CIRCUIT BOARD PROCESSING,
ELECTROPLATING, CLEANERS, RINSES
SPECIFICATIONS
FLOW RATE PUMP PUMP CART. SOLIDS SUCT. / DISCH. HOSE KIT
SYSTEM HP1 MAX. CHANGE MEDIA2 AREA CONNECTIONS PRICE
SIZE GPH LPH PSI PSI Sq. ft. Inches CODE NO.
J6M105 3 - 20" 21
J9M105 1,700 5,100 17 15 3 - 30" 31.5 1 x 1 FNPT 99-1608
J12M105 3 - 40" 42
J6M208 3 - 20" 21
15
1
Less than 1.0 HP single phase standard 2
Order media separately. Refer to Bulletin M-109.
1.0 HP and above three phase standard 3
PVDF systems 1" X 1" FNPT
PERFORMANCE
15
PSHJ12M208 PPSHJ12M208 CSHJ12M208 KSJ12M208 24 x 13 x 61 125
PSHJ6M310 PPSHJ6M310 CSHJ6M310 KSJ6M310 24 x 13 x 41 110
PSHJ9M310 PPSHJ9M310 CSHJ9M310 KSJ9M310 24 x 13 x 51 120
PSHJ12M310 PPSHJ12M310 CSHJ12M310 KSJ12M310 24 x 13 x 61 130
PS PVC chamber and polypropylene pump * CS CPVC chamber and polypropylene pump *
PPS polypropylene chamber and pump * KS PVDF chamber and pump *
ACCESSORIES
ADD TO
VITON ELASTOMERS
SYSTEM NO.
Filter chamber and pump V
PRICE PRICE
DESCRIPTION DESCRIPTION
CODE NO. CODE NO.
MOTOR STARTERS - NEMA 4X Watertight push button CARBON PURIFICATION CHAMBER
with ow control valve, hose & drain CPVC PVC
115 - 230V/1/50-60 O-MS1P
Order carbon media from Bulletin M-305
230 - 460V/3/50-60 O-MS3P
Includes ABS mini-canister / CPVC or clear
Add -S to Motor Starter PCN when ordering motor starter PVC chamber for
for use with DRI-STOP Pump Protector. i. e. O-MS1P-S 2.1 lbs. granular carbon 20" canister O-C2CM O-P2CM
Important: Specify operating voltage. 3.2 lbs. granular carbon 30" canister O-C3CM O-P3CM
OPERATING VOLTAGE Includes PVC canister / CPVC or clear PVC
chamber for
1 horsepower & above - Single phase O-1PH 7.5 lbs. granular carbon 5" x 28" canister O-1528C O-1528
Under 1 horsepower - Three phase O-3PH Includes CPVC or clear PVC chamber for
50 Hz OPERATION 1.2 lbs 20" carbon cartridge O-C2CC O-P2CC
1.8 lbs 30" carbon cartridge O-C3CC O-P3CC
Single phase @ 50 Hz O-150H 3.0 lbs 5" x 28" Maxi-carb cartridge O-1528M
Three phase @ 50 Hz O-350H
310
DIMENSIONS
15
in the electronics and metal nishing industries.
Featuring SERFILCO's non-metallic, leak-proof
magnetic coupled pumps and industry proven
Series 'J' lter chambers, these systems provide
high ow and high turnover rates, assuring continu-
ous particle removal. Space-Saver 'J' systems are
available with or without a carbon or resin purica-
tion chamber.
Choice of pump
Seal-less magnetic drive pumps:
Highly efcient seal-less magnetic coupled pumps
provide total solution containment and reliable perfor-
mance. The pumps are polypropylene with EPDM
"O"-ring.
Mechanical seal pumps:
Single or double mechanical seals constructed of
CPVC with EPDM elastomers and the highest grade,
longest lasting silicon carbide seal faces.
Filter chamber
Constructed of PVC or CPVC with EPDM elastomers
to ensure chemical and temperature compatibility.
The standard chamber accepts double open end
(DOE) depth wound, pleated, melt blown, cleanable
sleeve and carbon cartridges. A 222 "O"-ring seat for
single open end (SOE) cartridges is available.
Simple carbon or resin treatment
Space-Saver 'J' systems are also available with optional
purication chambers in PVC or CPVC with reusable
PVC canister offering a low-cost, but effective method
of continuously or periodically removing organic
impurities from plating baths and other chemical
solutions.
312
SPACE-SAVER 'J' FILTRATION SYSTEMS
Specifications and performance F-215B
MODELS M 1, 2 & 3
magnetic coupled pumps
'J' CARBON
CHAMBER CHAMBER
15
A
54-5/16"
3/4" NPT
CARBON
OUTLET
MODELS F 3, 4 & 5
magnetic coupled pumps
17-1/2"
22"
CHAMBER A
OUTLET
INLET
13-13/16"
F-215B
SPACE-SAVER 'J' FILTRATION SYSTEMS Specifications (continued)
Systems with polypropylene magnetic drive pump and CPVC or PVC 1 lter chamber
15
Flow Rate Pump Cartridge Filter Solids Suction / Disch. Shipping
System GPH LPH Pump Pump Max. Change Chamber Media Area Connections Weight
Number @ 60 Hz @ 50 Hz Series HP 3 PSI PSI Series (sq. ft.) (inches) (lbs.)
Systems with CPVC single or double seal 2 direct drive pump and CPVC or PVC 1 lter chamber
Flow Rate Pump Cartridge Filter Solids Suction / Disch Shipping
System GPH LPH Pump Pump Max. Change Chamber Media Area Connections Weight
Number @ 60 Hz @ 50 Hz Series HP 3 PSI PSI Series (sq. ft.) (inches) (lbs.)
CJ18HE610 3,000 9,500 HE 1.0 4 16 14 J 6 - 30" 63 2 x 1 FNPT 155
4
CJ24HE610 3,000 9,500 HE 1.0 16 14 J 6 - 40" 84 2 x 1 FNPT 165
1 3
Listed system includes CPVC chamber. To order system Less than 1.0 HP single phase standard.
with PVC chamber, change the C to P in System No. 1.0 HP and above three phase standard.
2 4
To order pump with double mechanical seal, 1.0 HP 'HE' pump is 1725 RPM @ 60 Hz,
change HE to HED in System No. 1450 RPM @ 50 Hz
314
OPTIONAL
ADD TO END OF
VITON ELASTOMERS SYSTEM NO.
Filter chamber and pump V
MOTOR STARTERS
DRI-STOP 3 for use with magnetic drive or single mechanical seal pump. O-DS3C
OPERATING VOLTAGE
1 horsepower and above - Single phase O-1PH
Under 1 horsepower - Three phase O-3PH
50 Hz OPERATION
Single phase @ 50 Hz O-150H
Three phase @ 50 Hz O-350H
SUPER SPACE-SAVER 315
15
Choice of pump: magnetic coupled, single
or double mechanical seal, self-priming
CPVC or Polypropylene direct drive2 pump with CPVC, PVC or Polypropylene1 lter chamber
Polypropylene magnetic drive pump with CPVC, PVC or Polypropylene lter chamber
Flow Rate Pump Cartridge Solids Suct. / Disch Overall Ship.
System Pump Pump Filter
GPH LPH Max. Change Media Area FNPT Conns. Dimensions Weight
Number Series HP Series
@ 60 Hz @ 50 Hz PSI PSI (sq. ft) (inches) (in.) (L x W x H) (lbs)
Listed system includes CPVC chamber. To order system with PVC chamber
change the rst C to P in System Number
For polypropylene systems, change the rst C to PP in System Number.
For PVDF systems, consult Sales Department
To order pump with double mechanical seal change HE to HED in System No.
317
15
Polypropylene magnetic drive pump with CPVC, PVC or Polypropylene lter chamber
Listed system includes CPVC chamber: To order system with PVC chamber - Change C to P in System No.
For polypropylene systems, change the first C to PP in System Number (Not available for CGB12HK415)
To order pump with double mechanical seal - Change HK to HKD or HE to HED in System No.
OPTIONAL
OPTIONAL ELASTOMERS
PRICE SLEEVES FOR CARTRIDGE CHAMBERS
CODE NO. (CPVC / POLYPROPYLENE)
'G' chamber with Hypalon and pump with Viton LENGTH / QUANTITY PRICE CODE
O-GH NO. OF
elastomers OF SLEEVE NUMBER FOR
10" CART.
MOTOR STARTERS - NEMA 4X Watertight push button ASSEMBLIES REQ'D COMPLETE SET
115 - 230V/1/50-60 O-MS1P 24 20"/12 O-2012
230 - 460V/3/50-60 O-MS3P 36 30"/12 O-3012
Add -S to Motor Starter PCN when ordering motor starter for 48 40"/12 O-4012
use with DRI-STOP Pump Protector. i. e. O-MS1P-S 60 50"/12 O-5012
Important: Specify operating voltage.
DRI-STOP PUMP PROTECTOR
DRI-STOP 2R for use with double mechanical
O-2DS2R
seal pumps
DRI-STOP 3 for use with magnetic drive or single
O-DS3C
mechanical seal pumps.
50 Hz OPERATION
Single phase @ 50 Hz O-150H
Three phase @ 50 Hz O-350H
GUARDIAN 318
Guardian Filtration Systems have gained clarity of your process solutions, increase produc-
wide approval for recirculatory purification of most tion quality, and reduce process cost.
electroplating and chemical process solutions. Choose a basic filtration system with your
They have proven to be a reliable workhorse for choice of media, pump and filter chamber. Then
over three decades. With hundreds of systems in select from a wide range of optional equipment to
service around the globe, you can be confident customize your system. Call us and we'll help you
a Guardian Filtration System will improve the select the perfect system for your application.
CPVC single or double seal 2 direct drive pump and CPVC or PVC 1 lter chamber
Flow Rate Pump Cartridge Solids Suct. / Disch Overall Ship.
System Pump Pump Filter
GPH @ LPH @ Max. Change Media Area FNPT Conns. Dimensions Weight
Number Series HP Series
60 Hz 50 Hz PSI PSI (sq. ft.) (inches) (in.) (L x W x H) (lbs)
CG24HE115H 4,200 13,200 HE 1.5 24 20 G 12 - 20" 84 2 x 11/2 50 x 24 x 32 205
15
CG48HE220H 5,400 17,000 HE 2.0 27 24 G 12 - 40" 168 2 x 11/2 50 x 24 x 52 240
Polypropylene magnetic drive pump and CPVC, PVC 1 or polypropylene lter chamber
Flow Rate Pump Cartridge Solids Suct. / Disch Overall Ship.
System Pump Pump Filter
GPH @ LPH @ Max. Change Media Area FNPT Conns. Dimensions Weight
Number Series HP Series
60 Hz 50 Hz PSI PSI (sq. ft.) (inches) (in.) (L x W x H) (lbs)
CG24M210H 3,000 13,200 M 1.0 20 16 G 12 - 20" 84 2 x 11/2 50 x 24 x 32 185
CG36F315H 3,900 12,300 F 1.5 2.0 16 G 12 - 30" 126 11/2 x 11/2 50 x 24 x 42 215
F-301H
GUARDIAN CARTRIDGE FILTRATION SYSTEMS
Polypropylene magnetic drive pump and CPVC, PVC 1 or polypropylene lter chamber (Cont.)
Flow Rate Pump Cartridge Solids Suct. / Disch Overall Ship.
System Pump Pump Filter
GPH @ LPH @ Max. Change Media Area FNPT Conns. Dimensions Weight
Number Series HP Series
60 Hz 50 Hz PSI PSI (sq. ft.) (inches) (in.) (L x W x H) (lbs)
CG36F420H 4,700 14,800 F 2.0 26 24 G 12 - 30" 126 11/2 x 11/2 50 x 24 x 42 225
CG96F850H 8,500 26,800 F2x2 5.0 45 33 (2)G 24 - 40" 336 2x2 66 x 24 x 52 395
CG120F850H 8,500 26,800 F2x2 5.0 45 33 (2)G 24 - 50" 420 2x2 66 x 24 x 62 425
CG96F910H 10,000 31,500 F2x2 10.0 53 42 (2)G 24 - 40" 336 2x2 66 x 24 x 52 460
CG120F910H 10,000 31,500 F2x2 10.0 53 42 (2)G 24 - 50" 420 2x2 66 x 24 x 62 490
Polypropylene magnetic drive pump and CPVC, PVC1 or polypropylene lter chamber
Flow Rate Pump Bag Suct. / Disch Overall Ship.
System Pump Pump Filter
GPH @ LPH @ Max. Area FNPT Conns. Dimensions Weight
Number Series HP Series
60 Hz 50 Hz PSI (sq. ft.) (inches) (in.) (L x W x H) (lbs)
CGB12F315H 3,900 11,300 F 1.5 20 G 12.0 11/2 x 11/2 50 x 24 x 42 215
15
Same as above, pluse backwash and bypass valves. 126 11 O-2073
168 + 18 O-2091
MOTOR STARTERS
NEMA 4X Watertight push button (mounted and wired) PRICE CODE NO.
Add -S to motor starter Price Code No. when ordering motor starter for use 115 - 230V/1/50-60 O-MS1P
with DRI-STOP Pump Protector IMPORTANT: Specify operating voltage 230 - 460V/3/50-60 O-MS3P
DRI-STOP PUMP PROTECTOR
DRI-STOP 2R for use with double mechanical seal pump. O-2DS2R
DRI-STOP 3 for use with magnetic drive or single mechanical seal pump. O-DS3C
SERFILCO's Guardian disc filtration systems incorpo- friendly" PVC mounting base. The systems include me-
rate all the latest pump, filter and media technology with chanical seal or magnetic-coupled pump and slurry tank
proven non-metallic materials and manufacturing techniques with valves. Piping, valves and connections are all CPVC
to provide a truly superior filtration system for your dollar. hard pipe with EPDM "O"-rings.
Guardian disc filtration systems include many standard
Even with all these features and benefits, the Guardian disc
features not available on competitive models. Standard
filtration system is competitively priced.
systems are built on a rugged corrosion resistant "fork lift
FEATURES
PUMP:
Industry proven Series 'M', Series 'F' or Series 'HE'. The uses convenient T-handles with stainless steel hardware.
Series 'M' magnetic-coupled pump, constructed of glass In addition, a 0-60 psi gauge with guard and gasketed vent
reinforced polypropylene with EPDM 'O'-rings, will pro- valve assembly are standard. The chamber base also includes
vide flow rates from 3,000 to 3,500 GPH. The Series 'F' additional drain ports for convenient servicing.
magnetic-coupled pump is also constructed of glass-filled
polypropylene with an EPDM 'O'-ring and will provide flow FILTER DISCS:
rates from 5,000 to 8,500 GPH. The Series 'HE' pump, which Molded high purity polypropylene discs are designed for
is constructed of CPVC with EPDM elastomers, is available optimum performance and high dir t loading area. Disc
with either single or double mechanical seals. It features sili- column has a positive O.D. seal and twist lock for easy
con carbide seal faces, the longest lasting, most durable seal disc removal. Disc media is available in 5, 10, 20 or 40 mi-
available. The 'HE' pump provides flow rates from 3,000 to cron rating. Carbon impregnated discs are also available.
8,500 GPH.
All pump motors are chemical service, continuous duty, TEFC, SLURRY TANK:
painted with two-part epoxy paint and stainless steel tag. 3/4" The standard polyethylene slurry tank is properly sized for
HP systems are 115-230V/1/50-60 Hz while systems 1 HP each system and includes all accessory valves to easily ac-
and above are 230-460V/3/50-60 Hz. All motors have a 1.15 complish several tasks. The slurry tank and valve package
service factor. can be used for:
pre-coat filter aid and / or carbon
FILTER: solution make-up or additions
The industry proven Series 'G' filter chamber features all pump priming
CPVC construction with EPDM elastomers at all con-nec- In addition, slurr y tanks are adequately sized to store
tions to assure solution containment. The cover closure solution during chamber maintenance.
323
Systems with polyproplene magnetic drive pump and CPVC or PVC filter chamber
FLOW RATE SURFACE SUCT./DISCH. OVERALL SHIP.
SYSTEM PUMP PUMP PUMP NO. *
GPH @ LPH @ SERIES HP MAX. OF AREA CONNS. DIM. (In.) WEIGHT
NUMBER
60 Hz 50 Hz PSI DISCS ft. m inches (l x w x h) (lbs)
CGD15M210H 3000 9450 M 1.0 24 31 15 1.4 1 x 1 50 x 24 x 25 185
CGD30M210H 3000 9450 M 1.0 24 65 30 2.8 1 x 1 50 x 24 x 35 195
CGD45M315H 4500 14,175 M 1.5 28 99 45 4.2 1 x 1 50 x 24 x 45 205
15
CGD60F420H 5500 17,300 F 2.0 29 130 60 5.6 1 x 1 66 x 24 x 35 325
CGD90F530H 6000 18,900 F 3.0 35 198 90 8.4 2x2 66 x 24 x 45 345
CGD90F850H 8500 26,800 F 5.0 45 198 90 8.4 2x2 66 x 24 x 45 355
Systems with CPVC single or double seal direct drive pump and CPVC or PVC filter chamber
CGD15HE610H 3000 9450 HE 1.0 16 31 15 1.4 2 x 1 1/2 50 x 24 x 25 185
CGD30HE610H 3000 9450 HE 1.0 16 65 30 2.8 2 x 1 1/2 50 x 24 x 35 195
CGD45HE115H 4500 14,175 HE 1.5 24 99 45 4.2 2 x 1 1/2 50 x 24 x 45 205
CGD60HE220H 5500 17,300 HE 2.0 29 130 60 5.6 2 x 1 1/2 66 x 24 x 35 325
CGD90HE330H 6000 18,900 HE 3.0 36 198 90 8.4 2x2 66 x 24 x 45 345
CGD90HE450H 8500 26,800 HE 5.0 50 198 90 8.4 2x2 66 x 24 x 45 355
SERFILCO worldwide leader in service, dependability and design for over 40 years!
325
SYSTEM: MEGA-FLO filtration systems are built on a All pump motors are chemical service, continuous
rugged hooded base assembly which protects the pump duty, TEFC with two-part epoxy paint. Motors are 230-
15
motor and supports the filter chamber. This design allows 460V/3/50-60Hz with 1.15 service factor.
maximum filtration performance while requiring minimal FILTER: Choice of PVC (140 F) or PPP polypropylene
floor space. (180 F) construction. Accommodates 130 cartridges for
PUMP: Your choice Series 'HE', 'H' or 'F'. PVC and 110 cartridges for PPP. Rugged machined shell,
Series 'HE' single or double seal pumps are available base and cover provide non-metallic solution contact.
in CPVC or PPP polypropylene. Series 'H' single or double The cover includes a 316 stainless steel reinforcing
seal pumps are constructed of CPVC. Both 'HE' and 'H' plate and lift handles. The chamber includes a 0 - 60 PSI
pumps feature EPDM elastomers and silicon carbide seals. gauge with guard assembly, vent valve assembly and
Double seal pumps include SERFILCO's award winning EPDM elastomers.
DRI-STOP seal protector.
Series 'F' 2 x 2 magnetic-coupled pumps are construct-
ed of glass reinforced polypropylene with Viton 'O'-ring.
* s. f. is square feet of surface area or solids holding capacity using Valuwound or Maxi-Depth filter cartridges.
(See Bulletin M-109.) Order cartridges separately.
** To order double seal pump, change HE to HED or H to HD in Price Code Number.
326
PJ52H3250 12,000 26 - 20" 5.0 (1725) H 3" x 3" 32" x 22" x 54" 305
PJ52H4375 18,000 26 - 20" 7.5 (1725) H 4" x 3" 32" x 22" x 54" 330
PJ52H4310 21,000 26 - 20" 10.0 (1725) H 4" x 3" 32" x 22" x 54" 355
* s. f. is square feet of surface area or solids holding capacity using Valuwound or Maxi-Depth filter cartridges.
(See Bulletin M-109.) Order cartridges separately.
** To order double seal pump, change HE to HED or H to HD in Price Code Number.
327
PUMP / HP A B C D E F
'HE' / 5.0 7-5/8" 8" 11-3/4" 2-3/4" 59-3/4" 25-1/4"
'F' / 5.0 7-3/4" 7-3/4" 11-3/4" 2-1/2" 59-3/4" 32-3/4"
'F' / 7.5 7-3/4" 7-3/4" 11-3/4" 2-1/2" 59-3/4" 32-3/4" E
'H' / 5.0 6-7/8" 10-7/8" 16-5/8" 3-5/8" 64-1/4" 32-3/4"
'H' / 7.5 7-1/4" 10-1/8" 16-5/8" 3-1/4" 64-1/4" 32-3/4"
'H' / 10.0 6-3/4" 9-5/8" 16-5/8" 3-3/4" 64-1/4" 32-3/4"
'E' dimension reflects 30" chamber. Add 10" for
15
40" chamber, add 20" for 50" chamber and subtract
10" for 20" chamber.
C
B
A D
22" F
OPTIONS
1
Chamber mounted on MEGA-FLO base (add 16" to length [F] dimension above)
2
Stand alone component as shown
3
Maximum recommended flow U.S. GPM
15
Systems with mechanical seals should be selected
of solids holding area per 50 gallons of solution. Flow rate
whenever excessive abrasives or ferrous metal particles
should be 2-10 tank turnovers per hour, depending on
are present. Standard single and double seal pumps
clarity desired. Coarse media and high flows are desirable
are CPVC and feature silicon carbide (SiC) seal faces
for high dirt load applications. Increasing the number of
with EPDM elastomers.
cartridges reduces solution flow per cartridge, improves
efficiency and reduces cartridge consumption. System
comes complete with flow control valve between pump
and filter chamber. When unit is de-energized, flow con-
trol valve may be closed to maintain prime during media
change.
** Chambers provided with the following Series 'CR'
systems are for cartridges.
To specify system for use with discs
Change CR1200 in System No. to DR60
Change CR1800 in System No. to DR78
or Change CR2400 in System No. to DR105
Sentry disc
chamber with RUBBER LINED CHAMBER with
cover removed
MAGNETIC DRIVE POLYPROPYLENE PUMP
OPTIONS
PRICE PRICE
DESCRIPTION CODE NO. DESCRIPTION CODE NO.
MOTOR STARTERS - NEMA 4X Watertight push button CARBON PURIFICATION CHAMBER
Order carbon media from Bulletin M-305.
230 - 460V/3/50-60 (3 - 7.5 H.P.) O-MS3P
Includes adapter kit, flow control valve, drain
230 - 460V/3/50-60 (10 - 15 H.P.) O-MS3P-S
valve and 10 ft. of nylon reinforced vinyl hose,
NOTE: Specify operating voltage PVC chamber and internal canister(s) for use
O-MS3P-S is required for any size system with granular carbon.
ordered with a DRI-STOP Pump Protector.
Single 5" x 28" canister, 7.5 lbs. capacity O-1528
DRI-STOP PUMP PROTECTOR Triple 5" x 28" canister, 22.5 lbs. capacity O-3528
15
DRI-STOP 2R for use with double mechanical Triple 5" x 48" canister, 42 lbs capacity O-3548
seal pumps. O-2DS2R Chamber for single 5" x 28" Maxi-Carb cartridge
DRI-STOP 3 for use with magnetic drive or (3.0 lbs. carbon)
single mechanical seal pumps. O-DS3C Polypropylene O-PP1528M
CPVC O-1528M
DAVIT COVER LIFT
GAUGE &
For Model: DR78 / CR180 78-1603 FILTER AIR RELEASE
DR105 / CR240 78-1604
TO PROCESS TANK
V1
PUMP
SLURRY TANK and VALVES PRICE DV7 CARBON FILTER
CODE NO. (DRAIN VALVE) V2
For chemical mixing, pump priming or TO PROCESS
precoating. Includes polyethylene tank, three V9 V10 TANK
additional CPVC flow control valves, steel
frame. Completely piped and assembled with
filter and pump on a standard base.
O-SV3-30 Standard Sentry with two flow control valves
30 gal. slurry w/3 add'l valves O-SV3-60
60 gal. slurry w/3 add'l valves
TANK GAUGE &
GAUGE &
V1 AIR RELEASE
V5 V4 AIR RELEASE
FILTER V1 FILTER
DV7
(DRAIN VALVE)
V2
PUMP
PUMP TO PROCESS
DV7 (DRAIN VALVE) V3 TO PROCESS V2 TANK
TANK
DISC MEDIA
BENEFITS
Improve finished goods quality, minimize
scrap and rework
Extend process solution life with continuous
dirt removal
Minimize downtime for tank maintenance and
sludge removal with high ow, large surface area
Protect heaters and other in-tank equipment
Economical to operate highly durable and
efficient cast centrifugal pumps and low PSI
drop chambers with easy cartridge change
Low installation cost pre-packaged
systems offer more flow and surface area than
SPECIFICATIONS competitive models
SYSTEM:
Models consist of a filter chamber, a cast cen-
trifugal single or double seal pump, TEFC motor, flow ler which is also constructed of 316 stainless steel.
control valve, piping, vent valve and pressure gauge, Standard pump elastomers are EPDM. Viton
all mounted on a rugged vinyl coated steel base. is available. Motors are TEFC, 208-230-460V, 3,
3450 RPM @ 60 Hz or 380-415V, 3, 2850 RPM @ 50
PUMP:
Hz. Specify operating voltage when ordering.
The Series 'HCI' (cast iron) and 'HSS' (cast
316 stainless steel) horizontal pumps feature a FILTER CHAMBER:
compact, close-coupled design. A high efficiency, Constructed of 304 stainless steel or carbon steel
semi-open impeller minimizes clogging and, since with an external coat of 2-part epoxy grey paint. The
the components are cast, there are no welds to break. chamber gasket is Buna-N. Chamber features 100 PSI
Also, cast construction provides corrosion resistance design with oversized inlet and outlet connections to
that is superior to welded styles. minimize pressure drop. Available for 5 - 10", 20" or
The self-priming Series 'SP' pumps are constructed 30" double open end cartridges providing 17.5, 35 or
of cast iron for dependable duty in a variety of ap- 52.5 square feet of dirt holding capacity respectively.
plications. The pumps include a 316 stainless steel Single bolt V-clamp cover closure allows quick and
shaft, 316 stainless steel fasteners, and cast iron easy media change.
mounting bracket. They feature a semi-open impel-
333
15
1.5
SS10HSS420H 4,000 34 2.0 5 - 20" 35 1" x 2" 30" x 13" x 39" 170
SS15HSS420H 4,000 34 2.0 5 - 30" 52.5 1" x 2" 30" x 13" x 49" 180
SS10HSS520H 4,500 40 2.0 5 - 20" 35 1" x 2" 30" x 13" x 39" 170
SS15HSS520H 4,500 40 2.0 5 - 30" 52.5 1" x 2" 30" x 13" x 49" 180
SS10HSS715H 5,500 20 1.5 5 - 20" 35 2" x 2" 30" x 13" x 39" 165
SS15HSS715H 5,500 20 1.5 5 - 30" 52.5 2" x 2" 30" x 13" x 49" 175
SS15HSS820H 7,500 30 2.0 5 - 30" 52.5 2" x 2" 30" x 13" x 49" 190
SS15HSS930H 9,000 36 3.0 5 - 30" 52.5 2" x 2" 30" x 13" x 49" 195
1
To order double mechanical water flush seal, change HSS To order steel system, change SS to S and HSS to HCI in
to HSSD or HCI to HCID in System No. System No.
4
2
FNPT x FNPT. With 2" diameter nominal string wound filter cartridges.
Order media separately. Refer to Bulletin M-109.
OPTIONAL EQUIPMENT
PRICE PRICE
DESCRIPTION CODE NO. DESCRIPTION CODE NO.
MOTOR STARTER - Assembled & installed Dri-Stop 2R
Specify operating voltage. Recommended for use with double me-
Watertight NEMA 4X magnetic push-button
chanical water flush seal pump. Automatically
with overload protection. O-2DS2R
de-energizes pump motor when cooling
For Start / Stop operation O-MS3P
water flow is interrupted. Eliminates costly
As above, but includes low voltage control O-MS3P-S dry run repairs. Requires MS3P-S motor
circuit required for use with Dri-Stop 2R starter, electric and water source.
KNIGHT 334
FEATURES
Flow rates 1,500 - 9,000 GPH @ 60 Hz
(7,875 - 28,350 LPH @ 50 Hz)
15
FILTER CHAMBER:
The SERFILCO KNIGHT filtration systems feature The series 'K' filter chamber is available in carbon
the most durable pumps and filter chambers in our steel, 304 stainless steel, or 316 stainless with an
product line. They are designed to provide years EPDM cover gasket (Viton optional). The chamber
of trouble-free service in demanding applications. is 150 PSI design with quick swing closure, and also
The KNIGHT systems are intended for use where includes differential, drain and vent parts.
thermoplastic systems are unsuitable due to chemi-
cal and / or temperature limitations. PUMP:
The series 'HSS', cast 316 stainless steel, or 'HCI',
SYSTEM: cast iron, centrifugal pumps feature a compact,
Models offer a choice of 304 or 316 stainless steel close-coupled design. A high efficiency, semi-open
lter chamber with a cast centrifugal 316SS pump, impeller minimizes clogging, and since the compo-
or a carbon steel lter chamber with cast iron pump. nents are cast, there are no welds to break. Also,
Systems include a ow control valve between pump cast construction provides corrosion resistance that
and lter, piping and 0-60 PSI pressure gange, all is superior to welded styles.
mounted on a rugged vinyl coated steel base plate. The pump is available with a single seal or with a double
seal which uses external liquid as a ush.Motors are
TEFC, 208-230-460V, 3, 3450 RPM, 60 Hz.
335
The following systems and specifications depict a Consult Sales Department for systems with self-
representative sampling of the Knight product line. priming pumps or for special systems featuring
Standard systems are shown for stainless steel or titanium pumps, Teflon lined chambers and special
carbon steel construction. Stainless steel systems seals for use with external applications such as
have a 304SS or 316SS filter chamber with a 316SS black oxide.
pump. Carbon steel systems have a carbon steel
filter chamber with a cast iron pump. EPDM elas-
tomers are standard for both.
15
SPECIFICATIONS AND ORDERING INFORMATION
304 stainless steel chamber with 316SS pump- single mechanical seal
FLOW SUR-
MAX. CONNECTIONS SHIPPING
SYSTEM PUMP FACE DIMENSIONS
PUMP MEDIA SUCTION X WEIGHT
NUMBER1,2,3 GPH@ LPH@ HP AREA L xW x H
PSI DISCHARGE lbs.
60 Hz 50 Hz sq. ft.*
1
For Vitan elastomers, add - V to System Number.
2
For 316 stainless steel filter chamber change k4s to k6s in System Number.
3
For double mechanical seal pump change HSS to HSSD in System Number.
* with 2" diameter nominal string wound cartridges. Order media separately. Refer to Bulletins M-109 and M-309.
Motors areTEFC, 230-460V/3/60 Hz. Consult Sales Dept. for explosion-proof, 50 Hz or 1 motors.
336
F-217 A
SPECIFICATIONS AND ORDERING INFORMATION
Carbon steel chamber with cast iron pump single mechanical seal
FLOW
MAX. SURFACE CONNECTIONS SHIPPING
SYSTEM PUMP DIMENSIONS
PUMP MEDIA AREA SUCTION X WEIGHT
NUMBER1,2 GPH@ LPH@ HP L xW x H
PSI sq. ft.* DISCHARGE lbs.
60 Hz 50 Hz
1
For Viton elastomers, add -V to System Number.
2
For double mechanical seal pump change HCI to HCID in System Number.
* with 2" diameter nominal string wound cartridges. Order media separately. Refer to Bulletins M-109 and M-309.
Motors areTEFC, 230-460V/3/60 Hz. Consult Sales Dept. for explosion-proof, 50 Hz or 1 motors.
OPTIONAL EQUIPMENT
PRICE PRICE
DESCRIPTION DESCRIPTION
CODE NO. CODE NO.
MOTOR STARTER - Assembled & installed Dri-Stop 2R
Specify operating voltage. Recommended for use with double
Watertight NEMA 4X magnetic push-button mechanical water ush seal pump. Au-
with overload protection. tomatically de-energizes pump motor
For Start / Stop operation O-MS3P O-2DS2R
when cooling water ow is interrupted.
Eliminates costly dry run repairs. Re-
As above, but includes low voltage control circuit
O-MS3P-S quires MS3P-S motor starter, electric
required for use with Dri-Stop 2R
and water source.
TITAN 337
16
BENEFITS
Dramatically reduces media and disposal costs.
Improves finished goods and process quality,
significantly increases yields, practically elimi-
nates scrap and rework.
Reduces chemical consumption by maintaining
solution quality.
Minimizes solution maintenance with high ow,
continuous particle removal.
Satisfy regulatory requirements by polishing
clarifier overflow.
Unique to any other filtration system available, the TITAN Easy to install and operate, manufactured with high
series is the result of SERFILCO's ongoing commitment quality corrosion resistant materials, TITAN systems
to developing "up flow" and "down flow" permanent will provide years of trouble-free operation.
media filtration technology. Hundreds of customers around the world have achieved
The combination of high flow permanent media, automatic dramatic improvement in quality while reducing costs
operation and proven success makes the SERFILCO using the automatic permanent media TITAN.
TITAN superior to any other filter available.
SERFILCO worldwide leader in service, dependability and design for over 40 years!
338
TITAN F-455N
The SERFILCO TITAN is a series of automatic backwash a digital electronic flow meter, pre-wired control panel and
systems which use permanent filter media of a specific size, pre-programmed microprocessor. Automatic control com-
shape and density that creates a filter bed through which con- ponents are housed in a NEMA 12 enclosure, factory wired
taminated solution is fed at controlled limits of flow and pres- and test cycled for all microprocessor programs.
sure. Microprocessor control automatically maintains constant Cleaner models have a steel chamber, piping and
design flow without compacting particles onto the media bed. valves and a cast iron single seal pump. Metal finishing
The automatic cycle, programmed for optimum use of models have PVC lined or hard rubber lined steel chambers
backwash fluid, responds automatically to a preset minimum with PVC piping and valves. Models designated ALK have
flow rate. Prior to the automatic backwash cycle, process solu- single seal cast iron pumps; models designated AC have
tions are purged from the system with low pressure air. During double seal CPVC pumps. Treated waste models have
the backwash cycle, particles exit the chamber without media PVC lined steel chambers with PVC piping and valves.
migration. The process occurs within minutes, resulting in an Models W-50, W-100, W-150 have double seal CPVC
extremely efficient backwash for each filter cycle. Re-establish- pumps. Models W-200 and larger have single seal cast iron
ment of the filtration cycle returns the system to design flow. pumps.
TITAN systems are specifically designed for use with All units are skid-mounted, though large sizes have
most aqueous process solutions including cleaners, plat- the chamber located separately. External metallic surfaces
ing and other metal finishing solutions, and treated final are painted with two coats of a two-part epoxy enamel. All
effluents. fasteners are stainless steel. Prior to shipment, all units are
Each TITAN system incorporates a corrosion resis- wet tested to insure piping integrity, ow rate and complete
16
tant filter chamber for use with permanent media and has system operation. Media is purchased and shipped separately.
electrically actuated valves, an efficient centrifugal pump, If required, backwash and recirculation tanks are also available
from SERFILCO.
RECIRCULATION
BACKWASH
TO WASTE
TREATMENT
TITAN
CLEANER
TANK BACKWASH
TANK
SEQUENCE OF OPERATION
A. Filtration C. Backwash with clean water
B. Air purge solution back D. Air purge backwash to waste
to cleaner tank treatment
RECIRCULATION BACKWASH
TO WASTE
16
TREATMENT
TITAN
PROCESS
TANK BACKWASH
TANK
SEQUENCE OF OPERATION
A. Filtration
B. Air purge solution back to process tank
C. Backwash with clean water
D. Air purge backwash to waste treatment
TREATED WASTE
Flow rates to 500 GPM
Capture low ppm suspended solids exiting in
clarifier overflow.
OPTIONAL CARBON PURIFICATION
16
Submicron particle retention
Follows other pre-filters
Does not require external, clean
backwash fluid
The 'Excel' Filtration System is an automatic back- The 'Excel' does not require disposable filter
wash filter which utilizes a floating permanent media and media, since it cleans itself automatically by means of a
unique "up flow" design to achieve sub-micron particle controlled backwash cycle which scrubs the unique float-
retention with single pass filtration. The 'Excel' Filtra- ing media and discharges the concentrated residue to a
tion System is specifically designed for final particulate receiving tank.
entrapment in critical applications that cannot be met
with other filtration methods.
Return
Backwash
Settling Sludge
Feedwater Backwash thickening Filter press
tank collection
collection tank
Existing system tank tank
'Excel' (control panel & (optional) Concentrated solids
(optional)
valves not shown) dewatering system
(available as necessary)
342
FEATURES - SPECIFICATIONS
Epoxy lined chamber with polyethylene filter media
Panel with programmable microprocessor
Electrically actuated valves (eight)
Manually adjustable isolation and throttling valves (seven)
Pump-motor assemblies (three)
Level controls for feedwater and backwash tanks
Flow meter
Pressure switches and gauges
Air regulator
Skid mounted, completely assembled, pre-wired and
tested to fit your application
Unit supplied with PVC or CPVC pipe, valves and fittings Pilot unit available for rental.
Consult Sales Dept.
FILTER
FILTER MEDIA MAXIMUM *COLLECTION PRICE
MODEL PIPE SIZE CHAMBER
VOLUME FLOW RATE TANKS CODE
NUMBER SIZE
NUMBER
cu. ft. cu. m NPT GPM LPM dia. x ht. Gal. Liters
EXCEL25 16 .45 2" 75 284 36" x 72" 960 3634 2854
EXCEL30 20 .57 2" 100 378 42" x 72" 1300 4921 2855
EXCEL48 40 1.13 4" 200 757 60" x 72" 2660 10069 2857
Plant air supply and electrical service required.
* Separate feedwater and backwash collection tanks required and optionally supplied as necessary.
SERIES 'DF' 343
Unattended operation
Automatically indexing media allows continuous
filtration, even with varying input or solids content.
Choice of materials
Carbon steel, 316 stainless steel, CPVC or
polypropylene
Sizes for any application
From 1.5 to 113 sq. ft. of filter surface area
17
Low operating cost
MODEL DF-11
TYPICAL
SYSTEM OPERATION INSTALLATION
This system is totally automatic and responds to wide
variations in flow rate and solids concentration. Pump the
contaminated solution to the diffuser tray which distrib-
utes flow across the full width of the filter bed. Particle
separation starts immediately via gravity flow through the
media to the clean reservoir below the conveyor frame.
Filtered solution can then gravity drain to waste or be
returned to the process via a pump.
SPECIFICATIONS
CARBON STEEL reservoir, frame, shafts, bearings and sprockets. Models 1.5 to 11 feature a 316 stain-
SERIES S less steel conveyor belt. Larger models have galvanized belt with optional 304 or 316 stainless steel
belt. Units are coated with corrosion resistant 2-part epoxy paint.
SERIES SS 316 STAINLESS STEEL reservoir, frame, shafts, bearings, sprockets and conveyor belt. Non-wetted
surfaces such as fabric bracket, motor bracket and gear reducer are carbon steel.
CPVC frame, polypropylene reservoir, conveyor belt and sprockets, Delrin bearings, HDPE sludge box.
SERIES CPP
PVC shafts on Model 1.5, 316 stainless steel shafts on Models 4 and larger.
SERIES PP POLYPROPYLENE reservoir, frame, sprockets and conveyor belt. Delrin bearings, PVC shaft, HDPE
sludge box. Available in 1.5 size only.
All units include: float switch, sludge box (HDPE on Models 1.5 and 4), a filtrate reservoir which serves as a support for mount-
ing the conveyor frame, drain, single phase drive motor and starter. Standard edge seals are PVC, 140F maximum. EPDM
and silicon rubber edge seals are optional. Order filter media separately.
17
COARSE
CODE NO. (LBS) CODE NO. (LBS) CODE NO. (LBS) CODE NO. (LBS)
RAYON / POLYESTER BLEND
SF-W025 25 100 49-0264 B 2 500 49-0111 B 14.5 500 49-0112 B 29 500 49-0113 B 44
SF-W020 20 100 49-0265 B 2 500 49-0070 B 18.0 500 49-0071 B 36 500 49-0072 B 55
SF-W010 10 50 49-0266 B 2 200 49-0114 B 14.0 200 49-0115 B 28 200 49-0116 B 43
FINE
SF-P040 40 100 49-0263 BPP 2 500 49-0108 BPP 12.0 500 49-0109 BPP 24 500 49-0110 BPP 36
SF-P025 25 100 49-0264 BPP 2 500 49-0111 BPP 14.5 500 49-0112 BPP 29 500 49-0113 BPP 44
SF-P020 20 100 49-0265 BPP 2 500 49-0070 BPP 18.0 500 49-0071 BPP 36 500 49-0072 BPP 55
* Add width to Model No. - Example: SF-W125-13" See Flow Rate Chart and Micron Selection Guide
OPTIONAL EQUIPMENT
DESCRIPTION PRICE CODE NO.
FLOAT ACTIVATED LEVEL CONTROL SWITCH FOR RESERVOIR PUMP
NEMA 4. For single phase motors to 11/2 HP @ 115V or 2 HP @ 230VAC. Used as a pilot device on three phase magnetic motor start-
49-0162
ers. Complete with oat ball and mounted in reservoir tank for pump-down operation. Separate motor starter is required for 3-phase
motor (see below).
RESERVOIR PUMP INSTALLATION AND WIRING 49-0173
MOTOR STARTER FOR RESERVOIR PUMP
O-MS3P-S
3 phase with transformer and 24VAC control circuit
O-MS1P-S
1 phase with transformer and 24VAC control circuit
NOTE: 1/15 HP to HP motors are 1 phase, 1 HP and up are 3 phase. 3 phase motors require a separate motor starter.
Quenching
SSU
OIL
2. Using the Flow Rate chart on the preceding page, Thread grinding - steel
SSU
OIL
determine the flow per square foot for the selected Flute - tap die grinding
viscosity and fabric. Crush & form grinding
ROLL-A-FILTER F-703D
17
install over sumps to eliminate frequent cleanout.
TO ORDER
W105 105 Straining paint / Coarse filtration 150 49-0175-1 49-0176-1 49-0177-1
POLY-
W090 90 Fine straining / Paint filtration / Light oil 150 49-0178-1 49-0179-1 49-0180-1
W080 80 Coarse filtration 150 49-0181 49-0182 49-0183
W055 55 Coarse filtration 150 49-0184 49-0185 49-0186
W040 40 Medium filtration 150 49-0187 49-0188 49-0189
RAYON
The Cartridge / Bag system is a 2-stage liquid- cron rating of the filter bags selected. The filter bags are
solid separation system designed to provide high solids attached to a manifold with cam-lock quick-disconnect
loading capabilities for applications requiring recirculat- couplings for minimal down-time when servicing. The
ing filtration of a process reservoir. Typical applications manifold includes an overflow vent which prevents back-
include the removal of particles from glass and plastic in up of system flow.
bottle washing operations and the removal of board fiber,
wheel grit, copper and other metals from water used in A circulating pump can be manually activated, or
PC board deburring and scrubbing equipment. automatically activated with an optional level control,
to transfer the filtered water from the primary filter tank
The first stage employs a primary filter tank con- to the second stage.This stage consists of a final trap
taining 8 gravity flow filter bags to collect bulk particles filter chamber which uses a 2 micron pleated paper filter
separated from rinse water. This stage provides 17.6 ft.2 cartridge with 32 sq. ft. of surface area to polish the
of filter surface area and is capable of filtering particles water so that clear water can be recycled to the process
from 100 micron to 5 micron, depending upon the mi- or discharged to a drain.
FEATURES:
Flow control valve
High solids loading PC BOARD OR BOTTLE CB FILTRATION
Vinyl coated steel base SCRUBBER SYSTEM
349
SPECIFICATIONS
50"
Entire system constructed of (1270mm)
corrosion resistant materials
for long service life. 13-1/2"
(343mm)
2" NPT
PRIMARY FILTER TANK 36" Inlet
(914mm)
Eight 5, 10, 25, 50 or 100 micron polypropylene filter bags (order 19"
separately) with quick-disconnect couplings provide 17.6 sq. ft. (483mm)
(1.6 sq. m) total area primary filtration by gravity flow to a 36" x
1" NPT
24" x 32" (914 x 610 x 813 mm) deep polyethylene Outlet
reservoir. Reservoir provided with cover.
TOP VIEW
AVAILABLE WITH: Motor Starter 1/2" NPT
(Optional) Drain
PVDF CENTRIFUGAL PUMP
Provides 30 U. S. GPM at 18 PSI @ 60 Hz (95 LPM at 1.2 Final Filter
bar @ 50 Hz) with Viton mechanical seal and "O"-ring. Chamber
Flow control valve on 1" PVC pipe between pump and Reservoir & Primary
final filter. 51" Bag Filters
or (1295mm) 2" NPT
NORYL SELF-PRIMING CENTRIFUGAL PUMP Inlet
Provides 30 U. S. GPM at 21 PSI @ 60 Hz (95 LPM at 1.4
bar @ 50 Hz) with Viton mechanical seal and "O"-ring.
17
Flow control valve on 1" PVC pipe between pump and
32-1/2"
final filter.
(826mm) 29"
FINAL TRAP FILTER CHAMBER
(737mm)
Constructed of PVC with quick opening swing bolts and tee
handles. Supplied with pressure gauge. Includes one 4" x 36"
pleated paper filter cartridge of 2 micron, 32 sq. ft. (3.0 sq. m.)
expanded filter area.
Pump-Motor
VINYL COATED STEEL BASE Motor Starter 2-5/8"
Approximate shipping weight - 200 lbs. (91 kg.) (Optional) SIDE VIEW (67mm)
LIQUID / SOLID
SEPARATION FOR:
MANUAL HYDRAULIC
0.6 to 3 cu.ft.expandable
SEMI-AUTOMATIC
1 to 50 cu.ft. expandable
AIR BLOWDOWN MANIFOLD
CORROSION RESISTANT
Model 25-48PP
with optional pneumatic 40-60% SOLIDS CONCENTRATION
plate spreader
LOW ENERGY REQUIREMENT
17
The Recessed Plate Filter Press will compact contact the Application Engineering Dept. to ar-
sludges to a dry cake with a density that is depen- range a pilot test.
dent upon the ultimate compaction pressure and Presses feature structural steel frame, coated
the characteristics of the particular sludge. with tough chemical resistant epoxy paint. High
Each pressload will require from 2-4 hours cycle density molded polypropylene filter plates are light
time. To insure adequate time, the press should be weight and corrosion resistant. Special polypropyl-
sized for at least 8 hours working capacity.The table ene quick cake release filter cloths. Air actuated
and formula below can be utilized to size your press. hydraulic system for parting and closing the filter
To confirm your sizing and evaluate the process plates. Automatic self-compensating hydraulic
for your application with a laboratory-sized model, system. Conveniently located operator control
console.
CALCULATIONS:
A X B X 8.33 LBS./GAL. (U.S. GALS./ 8 HRS.) X ( % SUSPENDED SOLIDS) X 8.33 LBS./GAL.
= CU. FT. CAPACITY
OR
C (AVERAGE LBS. DRY WT. / CUBIC FT.) FOR A DURATION
351
17
50-48PP 50 163 191 42 14,000 43-0650 43-0650G
1
Based on 1 thick lter cake. NOTE: Air blowdown connections are NPT on all models.
INCLUDES POLYPROPYLENE
PLATES AND FILTER CLOTH
Suitable for most waste solutions
The Lab Filter Press is designed for lab analysis and flow control valve, hoses, manual hydraulic pump
small batch production. This press is also very useful and drip pan. Entire assembly is mounted on a vinyl
for testing for upscaling to full production-size semi- coated steel base. Flow pattern is corner inlet with
automatic or manually operated presses. Includes three individual corner discharge lines.
polypropylene plates, filter cloth, air diaphragm
pump, pneumatic controls, pressure gauges, inlet
Drip Pan
Dimensions: 42" (1.1m) L x 13" (.33m) W x 22" (.56m) H
Shipping Weight: 95 Lbs (43 kg.)
Maximum operating temperature: 150 F (66 C) Test Slurry
OIL FILTRATION and 353
18
Oil reconditioning stations salvage contaminated oils for further
use by removing sludges, water and other suspended foreign material.
TRANS-O-FILTER Systems accelerate natural settling action with controlled elevated
w/optional coalescing chamber temperatures. Residual fine particulate are then removed by a polish-
ing filter of inert depth type media. If removal of oxidation products is
desirable, the polishing filter can be equipped with adsorbent Fuller's
Earth.
Optional coalescing chambers provide a means to separate
immiscible fluids such as tramp oil or water. These coalescers will handle
dissimilar liquids with specific gravity differences of 0.09 and greater. The
resulting effluent contains less than 10 PPM of the discontinuous phase.
STANDARD TRANS-O-FILTER1 SYSTEMS INCLUDE:
1. Carbon steel filter chamber with 75 psi maximum rating. "O"-ring closure i s
EPDM on portable model, Buna-N on all others.
2. Positive displacement self-priming gear pump with built-in relief valve set at
35 psi, Buna-N mechanical seal and 40 mesh suction strainer. Motor: 115-
230V/1/60, 1725 RPM, TEFC, with 8 ft. of 3-wire extension cord and 3-prong
plug. Units wired 115V standard.
3. Also available with air operated diaphragm pump, polypropylene with Teflon
internals.
4. 10' suction and discharge hoses (vinyl on portable; Buna-N and neoprene
on others).
5. Petcock vent and drain plug.
6. Pressure gauge mounted on gauge snubber to indicate dirty filter.
7. Completely assembled stationary models mounted on a vinyl coated steel
OIL RECONDITIONING STATION
for salvaging oils in large volume base. Mobile models include 2-wheel upright hand cart with handle.
8. Painted machine tool gray with two-part epoxy paint.
9. Optional coalescing chambers include Pyrex sight glass and coalescing
element 2.
1
For liquid temperatures up to 200F. 2 For liquid temperatures up to 160F.
354
H. P.
HAND-CARRY NO. GPH CARTS.* AREA HOSE SIZE Inches Lbs.
Includes protective hood and
sturdy carrying handle. 1402 A S10 S TS3 1 - 10" 3.5 sq. ft. 13 x 9 x 15 60
1429 180 3/8" x 3/8" 1/3 65
Painted machine tool gray. S20 S TS3 2 - 10" 7.0 sq. ft. 23 x 9 x 15
MACHINE MOUNT
With wall mount base plate.
1430 MMS20 S TS3 180 2 - 10" 7.0 sq. ft. 3/8" x 3/8" 1/3 14 x 14 x 7 60
Painted machine tool gray.
STATIONARY
1416 A S1(718) S TS6-PS 360 1 - 4" or 7" x 18" 29.0 sq. ft. 3/4" x 1/2" 1/2 30 x 13 x 30 105
1416 A2 S2(718) 1S TS9-PS 540 2 - 4" or 7" x 18" 58.0 sq. ft. 1" x 1" 1 30 x 13 x 50 125
Electric
1418 A S50(1) S TS3-PS 180 5 - 10" 17.5 sq. ft. 3/4" x 1/2" 1/3 30 x 13 x 25 100
drive
1422 A S100(2) S TS6-PS 360 10 - 10" 35.0 sq. ft. 3/4" x 1/2" 1/2 30 x 13 x 37 125
models
1426 A S150(3) 1S TS9-PS 540 15 - 10" 52.5 sq. ft. 1" x 1" 1 30 x 13 x 47 140
1441 S1(718) S PPTF-PRV 480 1 - 4" or 7" x 18" 29.0 sq. ft. 3/4" x 1/2" 5 @ 50 30 x 13 x 30 100
1441 2 S2(718) 1S PPTF1-PRV 600 2 - 4" or 7" x 18" 58.0 sq. ft. 1" x 1" 10 @40 30 x 13 x 50 120
Air
1442 S50(1) S PPTF-PRV 480 5 - 10" 17.5 sq. ft. 3/4" x 1/2" 5 @ 70 30 x 13 x 25 95
drive
1443 S100(2) S PPTF-PRV 480 10 - 10" 35.0 sq. ft. 3/4" x 1/2" 5 @ 70 30 x 13 x 37 120
models
1444 S150(3) S PPTF1-PRV 600 15 - 10" 52.5 sq. ft. 1" x 1" 10 @ 40 30 x 13 x 47 135
355
18
RECYCLING CUTTING OILS FOR RE-USE
250RS6-12-S4 1217A Consists of a 250 gallon 1000RS9-18-S4 1219A Consists of a 1000 gallon
cone bottom settling tank cone bottom settling tank
(not including cone capacity) with three 230 or 460V thermostat-controlled (not including cone capacity) with six 230 or 460V thermostat-controlled 10
5 kw immersion heaters, sight glass, hinged cover, 2" ball dump valve and kw immersion heaters, sight glass, hinged cover, 2" ball dump valve and
platform ladder. One 275 gallon clean oil storage tank with sight glass and platform ladder. One 1000 gallon clean oil storage tank with sight glass and
draw valve. Twelve-cartridge filter vessel, pressure gauge and vent valve. draw valve. Eighteen-cartridge filter vessel, pressure gauge and vent valve.
Piped to a 6 GPM positive displacement gear pump with suction strainer and Piped to a 9 GPM positive displacement gear pump with suction strainer and
internal relief valve, close-coupled to a H.P., 115-230V/1/60 TEFC motor, internal relief valve, close-coupled to a H.P., 115-230V/1/60 TEFC motor,
with NEMA 4 motor starter. Components interconnected with " piping and with NEMA 4 motor starter. Components interconnected with 1" piping and
lever handle brass valves for instant reference to open or closed position, lever handle brass valves for instant reference to open or closed position.
10' suction and discharge hoses. Approximate floor space 5' x 6'. Unit is 7'-1" 10' suction and discharge hoses. Approximate floor space 11' x 10'. Unit is
high. Allow 2'-3" clearance for hinged cover. 13' high. Allow 3' clearance for hinged cover.
tanks (not including cone capacity), each with six 230 or 460V thermostat-
two-part epoxy enamel paint. Consult
controlled 10 kw immersion heaters, sight glass, hinged cover, 2" ball dump
Application Engineering Dept. for custom
valve and platform ladder. One 1000 gallon clean oil storage tank with sight
systems, addition of coalescing chamber
glass and draw valve. Eighteen-cartridge filter vessel, pressure gauge and
or substitution of pump or filter chamber.
vent valve. Piped to a 9 GPM positive displacement gear pump with suction
Order filter cartridges separately.
strainer and internal relief valve, close-coupled to a H.P., 115-230V/1/60
Automatic heating
TEFC motor, with NEMA 4 motor starter. Components interconnected
Hinged cover
elements inside with 1" piping and lever handle brass valves for instant reference to open or
closed position. 10' suction and discharge hoses. Approximate floor space
Sight glass 16' x 10'. Unit is 13' high. Allow 3' clearance for hinged cover.
to see liquid level
Overflow piping
Feed line to
pump and filter
CHAMBERS R-102P
Fewer rejects
Series 'HF'
Carbon canister
19
tion (shown below) provides side-stream ow through
Carbon canister is inter-
carbon for best control of results. One or two months
changeable with Maxi-Carb
carbon cartridge. of operation is not unusual before carbon change is
necessary.
Series 'G'
Bulk carbon or canister
FILTER
Complete matched systems pump, filter, CARBON
carbon chambers are available to meet any TANK
size and type of production requirement.
TO TANK
358
Chamber made of CPVC, PVC or PP with polypropylene trap screens. Swing bolt cover closure and pressure gauge with diaphragm guard.
When ordering PVC chamber, change CL to PL in Model Number. To order PP chamber, change CL to PPL.
SERIES 'S' & 'G' w/CANISTER FOR GRANULAR CARBON 3 Canister Lbs. PVC CPVC
Chamber made of CPVC or PVC with PVC canister with Saran inlet screen and a built-in trap filter. Swing bolt cover closure and pres-
sure gauge with diaphragm guard. When ordering PVC chamber, change CL to PL in Model Number.
SERIES 'S' & 'G' w/MAXI-CARB CARTRIDGE Cartridge Lbs. PVC CPVC PP
CL1(528M)CS 1-G3 S 1 - 5 1 3 78-1626 78-1626 C 78-1626 PP
CL3(528M)CSIO 1-G3A G 3 - 15 3 9 78-1963 P 78-1963 C 78-1963 PP
CL3(548M)CSIO 1-G3A G 6 - 15 3 17 78-1965 P 78-1965 C 78-1965 PP
Chamber made of CPVC, PVC or polypropylene. Swing bolt cover closure and pressure gauge with diaphragm guard.
When ordering PVC chamber, change CL to PL in Model Number. To order PP chamber, change CL to PPL.
Chamber made of PVC with PVC canister with Saran inlet screen and a built-in trap filter.
Swing bolt cover closure and pressure gauge with diaphragm guard.
19
1
Design flow rates may vary, but the lower value offers the maximum adsorbency and the most efficient purification
for each gallon processed.
2
To order trap filter cartridges, see Bulletin M-109
3
May also be used with C528PE and C548PE powdered carbon cartridges. See Bulletin M-305. (Ordered separately)
SYSTEMS R-103K
Eliminates down-time
Labmaster
Compact pre-engineered systems can be used on
multiple baths thus saving in equipment cost
Magnetic-coupled pump
Optional pre-filter
19
Guardian
Granular Carbon Purication Systems provide a simple, Seal-less, leak-proof pumps are rugged enough for
economical and efficient method of removing organic continuous duty in systems that require total flow through
impurities from electroplating or other chemical solutions. the carbon chamber for effective organic removal, or
Three product lines are offered: Labmaster, Space-Saver, they can be used at partial flow, as required. Units can
and Guardian. The user can choose the particular model be connected to a plating bath for continuous carbon
that is right for his/her application, flow rates, and the treatment, then disconnected and used on another tank.
Thus, one system can serve several tanks.
degree of solution purity required. Carbon canisters
include trap filter. Pre-filters, offered optionally, protect the carbon from
contamination by efficient removal of solid impurities
Connect the Carbon Purification System to your plating
that could render the carbon inefficient.
tank to achieve efficient organic removal. Select a system
with replaceable carbon cartridges or with a chamber which Larger and custom systems available to meet your particular
has removable and refillable bulk carbon canister. The application. Consult Sales Dept. for assistance.
latter also accept C528PE powdered carbon cartridges
which are interchangeable with the canisters.
360
The following systems are designed for full flow through a filter and from the solution being treated. Therefore, the filters offered on these
purification chamber. These systems are usually used in conjunction systems are sized to hold only the solids which have not been picked
with filtration systems which are sized to remove the bulk of solids up with the main filter.
w/CPVC w/PVC
SPACE-SAVER WITH CANISTER FOR CARBON WITHOUT OR WITH PRE-FILTRATION
Chamber Chamber*
CL1(528)S 3/4V BPSV-G3 7 lbs. carbon S-0413 A S-0413 AA
11/2 - 5 13 13 x 9 x 47 1/6
CL1(528)S x PCL30 3/4V BPSV-G3 for 1 canister 3 of 15U10U S-0414 A S-0414 AA
Systems are assembled without or with clear PVC pre-filter chamber polypropylene fittings. System, mounted on a corrosion resistant base,
for depth cartridges as indicated and a CPVC carbon chamber with includes -G3 pressure gauge on polypropylene gauge guard with
one PVC refillable canister with trap filter for granular carbon. The EPDM diaphragm.
pump is magnetic-coupled, made of glass-filled polypropylene. * For PVC change CL to PL in model number.
Reinforced vinyl hoses, 10 ft. suction and 10 ft. discharge, CPVC and
w/CPVC w/PVC
GUARDIAN WITH CANISTERS FOR CARBON WITHOUT OR WITH PRE-FILTRATION
Chamber Chamber*
CL3(528P)CCS 3/4C MPLCR 1A-C.5-G3A 21 lbs. carbon S-0357 F S-0357 FA
41/2 - 15 22 33 x 18 x 53 1/2
CL3(528P)CCS x CL60(2)S 3/4C MPLCR1A-C.5-G3A for 3 canisters 6 of 15U10U S-0358 F S-0358 FA
Systems are assembled without or with CPVC or PVC pre-filter chamber hoses, 10 ft. suction and 10 ft. discharge, CPVC and polypropylene
for depth cartridges as indicated and a CPVC carbon chamber with fittings. System, mounted on an FRP base, includes -G3A pressure
three PVC refillable canisters with trap filter for granular carbon. The gauge on polypropylene gauge guard with EPDM diaphragm and CPVC
pump is magnetic-coupled, made of polypropylene. Reinforced vinyl air release valve. * For PVC change CL to PL in Model Number.
19
ADD TO PRICE
OPTIONAL
MODEL CODE NO.
Portable - addition of two wheels For Labmaster 20" & 30" models and Space-Saver -P O-0191
-two xed wheels, two swivel casters For Guardian -P O-0454
Flow control valve on pump discharge 1
/2" for Labmaster -V1 O-CV12
3
/4" for Space-Saver, Guardian -V1 O-0984
Motor starter with overload protection, push button, waterlight, 1 phase -ST4 O-MS1P
Optional 3-phase (for all systems except Labmaster) O-MS3P
Operating voltage - under 1 HP, 3-phase motor (except Labmaster) O-3PH
50 Hz operation - Consult Sales Dept.
1 3
Design flow rates may vary, but the lower value offers the maximum adsorbency (528P) canister includes 03U10U trap filter cartridge.
and the most efficient purification for each gallon processed. 4
Filter cartridges, carbon cartridges and bulk carbon must be ordered separately.
2
All motors are 115/230V/1/60, 3450 RPM and include 8 ft. of 3-wire cord and To order: Filter cartridges, see Bulletin M-109
plug. Motors are wired for 115V operation, unless otherwise requested. Carbon cartridges, see Bulletin M-109
Bulk carbon, see Bulletin R-102
F.O.B. Northbrook, Illinois Specification subject to change without notice.
361
Standard Air Operated systems include: EPDM gaskets (prefilter and coalescer)
Polypropylene air operated diaphragm pump Light and heavy phase discharge valves
with Teflon internals on coalescer
Air pressure regulator Corrosion resistant mounting base
Plastic prefilter chamber and coalescer 10 ft. suction and discharge hoses
Air operated plastic coalescing systems are best suited for Air operated diaphragm pump features excellent dry run
separation of oils from aqueous based solutions. Non-metallic capability and will self-prime to 10 ft.
solution contact allows a wide range of chemical compatibility.
Electric operated plastic coalescing systems are best suited for Electric pump features Buna-N exible impeller for limited dry
separation of oils from aqueous based solutions. Non-metallic run capability. When wetted, pump will self-prime to 5 ft. Spare
solution contact allows a wide range of chemical compatibility. impeller is recommended.
1
Filter media and coalescing media ordered separately.
363
480 1363 S-1283 5 @ 50 PPTF" 5-10" carbon steel 1-4" x 11" carbon steel 42" x 13" x 37" 150
480 2271 S-1284 5 @ 50 PPTF" 5-20" carbon steel 1-4" x 11" carbon steel 42" x 13" x 37" 160
600 5678 S-1285 10 @ 40 PPTF1" 5-30" carbon steel 1-4" x 11" carbon steel 42" x 13" x 37" 170
480 1363 S-1286 5 @ 50 PPTF1/2" 5 - 10" 304 stainless steel 1-4"x11" 304 stainless steel 42" x 13" x 37" 155
480 2271 S-1287 5 @ 50 PPTF1/2" 5 - 20" 304 stainless steel 1-4"x11" 304 stainless steel 42" x 13" x 37" 165
600 5678 S-1288 10 @ 40 PPTF1" 5 - 30" 304 stainless steel 1-4"x11" 304 stainless steel 42" x 13" x 37" 175
Air operated metal coalescing systems are ideal for use diaphragm pump features excellent dry run capability and will
with petroleum, alkaline and other solutions. Air operated self-prime to 10 ft.
180 567
SYSTEM
NUMBER
S-1277
PUMP HP,
MODEL
1/3, TS3
MEDIA
5 - 10"
MATERIALS
OF CONST.
carbon steel
MEDIA
1-4"x11"
MATERIALS
OF CONST.
carbon steel
L xW x H
Inches
175
20
360 1134 S-1278 1/2, TS6 5 - 20" carbon steel 1-4"x11" carbon steel 42" x 13" x 37" 195
540 1701 S-1279 1, TS9 5 - 30" carbon steel 1-4"x11" carbon steel 42" x 13" x 37" 215
180 567 S-1433 1/2, TSS3 304 stainless steel carbon steel 1-4" x 11" 304 stainless steel 42" x 13" x 37" 200
300 945 S-1434 3/4, TSS5 304 stainless steel carbon steel 1-4" x 11" 304 stainless steel 42" x 13" x 37" 225
Electric operated metal systems are ideal for use in separating uids having lubricity and small particulate load. Gear pumps
tramp oil or trace water from petroleum, hydraulic, synthetic are self-priming and will lift to 10 ft.
and machining uids. Rotary gear pumps are best suited for
364
PREFILTER MEDIA
COALESCING MEDIA
* Viton end caps (4 x 11 size only). Minimum order carton quantity. Add -V to Model and Price Code Number.
SKIMMER ASSEMBLY
Connect to pump suction to skim oating oils or debris. Constructed of polypropylene and CPVC.
FLOATING
TO INLET / OUTLET ** RISER BRACKET
OVERFLOW LIQUID SKIM
WEIR PUMP MODEL NPT PRICE
LEVEL RATE INLET 1/2"
NUMBER LENGTH CODE NO.
SURFACE FLOW DIFFERENTIAL GPH PIPE PORT LENGTH THICK
RISER SK 1/2 2" to 300 1/2" 3/8" 15" 13" 4" x 2" 99-0479
SK 3/4 3" to 600 3/4" 1/2" 18" 18" 4" x 2" 99-0498
BODY
SK 1 4" to 900 1" 3/4" 18" 18" 6" x 2" 99-0480
20
To select skimmer: 1. Determine tank liquid level differential. ** SK to SK 1 have NPT inlet and hose
This will minimize dry pump operation. adapter outlet, "C" clamp, hose clamp,
2. Use skim rate as guideline for sizing. lock screw and elbow hose adapter.
- Consult Sales Dept. for other skimmer
sizes.
OPTIONAL
PRICE
DESCRIPTION
CODE NO.
Motor starter Model -ST4 O-1214
Portable - 2 wheels and 2 legs on standard mounting base
O-0191
(metal & plastic systems)
Sight glass for 1500 GPH coalescing chamber O-1435
Viton chamber elastomers / Viton impeller (J-pumps) Add -V to System No.
365
BENEFITS
Maintains solution surface free of oil
Extends life of primary solution
Less cleaning of piece parts
SKIM-BELT Simplifies reclamation and disposal
Collected oil can be sold, burned or filtered
and reused
INSTALLATION
Mount the unit with 2-3 inches of the wheel or
belt in the fluid.
Mount in a safe area and protect from spraying
fluids.
A ground fault circuit interrupt device and
The SERFILCO Skim-Disc or Skim-Belt are inexpen- proper grounding are required for electrical
sive investments when compared with fluid costs, installation.
maintenance costs and process effectiveness. The Run when oil is floating on the surface. The best
equipment pays for itself in a very short time. For time may be during downtime when the fluid is
ease of operation and cost effectiveness SERFILCO motionless.
oil skimmers outperform other methods.
SKIM-DISC SKIM-BELT
14-1/2(12 DIA. WHEEL)
20-1/2(18 DIA. WHEEL)
3-5/8
2-3/4 8-1/16
MOTOR
MOTOR
DRAIN
3 14-7/8
DRAIN
8-1/4
3 (4) 9/32 DIA
MOUNTING
2
HOLES
SKIM-DISC
DISC DISC SHIPPING PRICE
MODEL
MATERIAL DIAMETER WEIGHT CODE NO.
SD12 - PH 12" 12 lbs 99-0470
phenolic
SD18 - PH 18" 15 lbs 99-0471
SD12 - SS 12" 13 lbs 99-0468
stainless steel
SD18 - SS 18" 16 lbs 99-0469
20
SKIM-BELT
Note: Standard voltage is 115V/1/60.
BELT SHIPPING PRICE
MODEL For 220V/1/50, add -S to Model
SIZE WEIGHT CODE NO. and Price Code No.
SB12 12" x 2" 13 lbs 99-0472
ION EXCHANGE RESIN 367
CONSTRUCTION
Chambers are available in translucent PVC, PVC, or berglass reinforced
polyethylene shell, in sizes from 0.15 to 15 cubic feet of resin. Built-in
strainers help prevent resin migration. Seal-less magnetic coupled
pumps provide leak-proof operation with minimal maintenance. All
systems are mounted on a base, ready to connect and operate.
GUARDIAN "SPECIAL"
PLUS OPTIONAL . . .
SYSTEMS
MAXIMUM
FLOW RESIN FILTER
FLOW SHIP. PRICE
RATE1 MAX CHAMBER CHAMBER HT. TEFC
MODEL RATE WT. CODE
PSI (cu. ft of (recommended (in.) MOTOR
(lbs.) NO.
GPH resin)3 depth cartridge)2
LABMASTER SYSTEMS FOR BULK RESIN - (A) without pre-lter and (B) with pre-lter
System is mounted on a PVC hooded base. To order system with canister for resin, change R to RC in
Model No. and add C to Price Code No.
SPACE-SAVER SYSTEMS FOR BULK RESIN - (A) without pre-lter and (B) with pre-lter
(A) PL630RS 3/4V BAPSV -- 95 0383 C
(B) PL630RS x PCL20 3/4V BAPSV 2 of 15U10U 1/6 HP 105 0380 D
72 480 13 .5 47 115/230V/
(A) PCL630RS 3/4V BAPSV -- 1/60 95 0384 A
(B) PCL630RS x PCL20 3/4V BAPSV 2 of 15U10U 105 0380 C
System is mounted on a PVC hooded base. To order system with bag resin (one .5 cu. ft. bag), change
To order system with canister for resin, change RS to RCS RS to RBS in Model No. and add B to Price Code No.
in Model No. and add C to Price Code No.4
GUARDIAN SYSTEMS FOR BULK RESIN - (A) without pre-lter and (B) with pre-lter
System is mounted on a vinyl coated steel base. To order system with bag resin (two .9 cu. ft. bags),
To order system with canister for resin, change RS to RCS change RS to RBS in Model No. and add B to Price Code
in Model No. and add C to Price Code No.4 No.
OPTIONAL EQUIPMENT
Add to PRICE
DESCRIPTION FOR SYSTEM
MODEL NO. CODE NO.
1/2" NPT Labmaster, 0981
Flow control valve -V1
3/4" NPT Space-Saver, Guardian 0984
Motor starter w/overload protection, pushbutton, Labmaster,
-ST4 MS1P
NEMA 4 watertight, 115V/1/50-60 Space-Saver, Guardian
Portable - two wheels Space-Saver 0378
-P
Portable - two xed wheels, two swivel casters Guardian 0454
Priming chamber for 6 MRGR Guardian -PC4 PC4
INITIAL RESIN SHIP PRICE To order chamber with canister for resin, change R to
MODEL FLOW RATE 1 CAPAC. WT. CODE RC in Model Number and add C to Price Code No.
(GPH) (cu. ft.) (lbs.) NUMBER For mounting bracket, add Price Code No. 44-3200 1.
PCL30R-3/4 30 - 100 .15 9 78-1633
BULK RESIN MUST BE ORDERED SEPARATELY. SEE PREVIOUS PAGE AND BULLETIN R-208.
ALL ION EXCHANGE CHAMBERS / SYSTEMS CAN BE USED WITH GRANULAR CARBON.
SEE BULLETIN R-103 FOR ADDITIONAL CARBON PURIFICATION CHAMBERS.
371
FOR MAKE-UP WATER AND RECIRCULATED RINSES Supplied in the sodium form, will remove heavy metals
Mixed bed resin is designed for use in a single column from rinse waters for discharge. It will also remove calcium and
or multiple columns in series to provide water to a 20,000 ohm magnesium which will reduce its capacity for copper, nickel,
endpoint (25 ppm). Average quality less than 0.1 ppm prior to trivalent chromium. We suggest the use of softened rinse water.
breakthrough. Use to demineralize make-up water such as for
plating and EDM.
When used in recirculating rinses, the estimated capacity
DESCRIPTION TYPE PART NO. *
per cu. ft. is 470,000 divided by the MMHOS or 235,000 divided Sodium form C100ELT 1375
by ppm TDS.
When regenerated and reused, the capacity will only be Same function as the sodium form, but the discharge
50 to 70% of the virgin resin. will be acidic. The cation resin in the hydrogen form is used
with the anion resin in the OH form (A600-OH) in two-step
DESCRIPTION TYPE PART NO. * demineralization processes.
Mixed bed resin NRW37 1328
Mixed bed resin Hydrogen form C100H 1376
NRW37IND 1328D
w/indicator dye
An anion resin in the OH form, maintains a high pH and Heavy metal removal from
S950
helps prevent formation of hydrogen cyanide gas. Capacity for waste streams.
gold is 100 ounces per cu. ft. maximum. This anion resin is also 1310
* Price per cubic foot.
used in two-step demineralization systems with the cation resin Consult Sales Department for quantity pricing
in the hydrogen form. and special packaging.
Resin for alkaline gold To order .5 cu. ft. bag - add .5B to Part No.
or silver recovery A600OH 1316 To order .9 cu. ft. bag - add .9B to Part No.
GENERAL 372
LINERS, RINGS
PLASTICS METALS and SEALS ELASTOMERS
A E P P E P P C P N R C 3 3 H T C N G. B V E H N C
B C T V T O V P O O Y A 0 1 A I E I U I P Y E O
F.
S T F D F L C V L R T R 4 6 S T R C N T D P O R
1. Good for 200F (93C) F E F E Y C Y Y O B T A A K A O M A P K
T
2. Good for 185F (85C) E E P L N O S S E N M E N L R -
(KYNAR)
F
(TEFLON)
3. Good for 140F (60C) S R N T. T. L I I L N O E N
(TEFZEL)
(HALAR)
E
4. Good for 70F (21C) T O L U C A N N I
(ETH. PROP.)
E P S S S O M G E T
(M1 x M2)
Q Questionable R
R* Y T T T Y R
(RULON)
NR Not recommended A
L E E E I
No data available P
E E E E C L
N L L L H E
E I
T
E
Acetaldehyde 1 4 4 NR NR 4 1 Q 1 1 1 1 1 1 1 NR Q 3 NR NR Q
Acetic Acid, 20% 1 1 1 1 NR 4 4 3 3 2 NR Q 1 1 1 1 1 1 3 NR 2 1 Q 3
Acetic Acid, Glacial 3 1 4 4 NR NR NR 4 1 1 NR Q 1 1 1 1 Q 1 4 NR 2 Q NR 3
Acetic Anhydride 4 1 NR 4 NR NR NR 4 3 1 NR 1 1 1 1 1 Q 1 NR NR 2 1 NR Q
Acetone 3 1 NR Q NR NR NR 4 NR 1 1 1 1 1 1 1 1 1 NR NR 4 Q Q NR
Aluminum Chloride 1 1 1 1 NR 3 1 2 1 1 NR Q Q 1 1 1 NR 1 1 1 1 1 1 3
Aluminum Fluoride 1 1 1 1 NR 3 1 2 4 1 NR Q Q 3 Q NR NR 1 1 1 1 1 1 3
Aluminum Sulfate 1 1 1 1 4 3 1 2 1 1 1 1 Q 1 1 1 1 1 1 1 1 1 1 3
Ammonia, Aqueous 1 1 1 4 NR 4 4 2 4 4 1 1 1 1 1 1 4 NR 1 1 1
Ammonium Carbonate 1 1 1 1 Q 3 1 2 3 1 Q 1 1 2 1 1 1 1 NR 4 1 1 1
Ammonium Chloride 1 1 1 1 4 3 1 2 1 1 Q Q Q 2 3 1 NR 1 2 1 1 1 1 3
Ammonium Hydroxide 1 1 1 1 4 4 NR 2 1 1 2 1 1 1 1 1 1 1 4 1 1 1 1
Ammonium Nitrate 1 1 1 1 4 3 1 2 1 1 Q 4 4 3 1 1 1 1 1 2 1 1 1 3
Ammonium Phosphate 1 1 1 1 4 3 1 2 4 1 NR 1 Q 1 1 1 Q 1 1 Q 1 1 1 3
Ammonium Sulfate 1 1 1 1 4 3 1 2 1 1 Q Q Q 1 1 4 Q 1 1 Q 1 1 1 3
Amyl Acetate 3 1 NR Q 4 NR NR NR NR 1 1 1 1 1 1 1 NR NR Q NR NR Q
Amyl Alcohol 1 1 1 4 4 Q 2 4 1 Q 1 1 1 1 1 1 1 4 NR 4 2 3 3
Aniline 4 1 3 4 NR NR NR 2 NR 1 Q 1 1 1 Q 1 1 1 NR 2 2 Q NR Q
Aqua Regia 2 2 NR 4 NR NR Q Q NR NR NR NR NR NR Q 1 1 1 NR 2 NR 4 Q Q
Arsenic Acid 1 1 1 1 NR 3 1 2 4 1 NR 1 Q 1 1 1 1 1 1 1 1 1 1 3
Barium Hydroxide 1 1 1 1 Q 3 1 2 3 1 1 3 1 1 1 1 1 1 1 1 1
Barium Chloride 1 1 1 1 4 3 1 2 1 1 4 1 1 1 Q 1 NR 1 1 1 1 3
Barium Sulfate 1 1 1 1 4 3 1 2 4 1 3 1 1 1 1 1 1 1 1 1 1 3
Benzaldehyde NR 4 1 4 4 NR NR 4 2 3 1 1 1 1 1 1 NR NR Q NR NR Q
Benzene (Benzol) NR 3 1 2 2 4 NR NR NR 3 1 1 1 1 1 1 1 1 1 NR 3 NR NR NR 3
Benzene Sulfonic Acid 3 1 3 4 Q NR NR Q 1 1 1 1 1 1 1 1 NR 2 NR NR NR
Benzoic Acid 1 1 1 1 4 3 1 2 4 1 3 1 1 1 1 1 NR 2 NR NR NR Q
Borax (Sodium Borate) 1 1 1 1 4 3 1 2 4 1 1 1 1 1 4 1 4 3 1 3 4 3
Boric Acid 1 1 1 1 4 3 1 2 4 1 2 1 1 1 1 1 2 2 1 2 1 3
Bromine Water 1 1 2 1 NR 3 4 NR 4 Q NR NR NR 1 1 1 4 1 NR 1 Q NR Q Q
Butyl Acetate 3 1 NR 4 4 NR NR NR 2 1 Q 1 1 1 1 1 Q 1 NR NR Q NR NR NR
Butyl Alcohol 1 1 1 1 Q 4 Q 2 4 1 1 1 1 1 1 1 1 1 Q Q 3 3 3
Butyl Amine 1 NR 4 Q NR Q 3 2 4 1 1 1 1 1 1 NR Q 4 4 NR
Butyl Phthalate 1 3 3 Q NR NR NR 3 4 1 1 1 1 1 1 NR Q 4 NR NR
Butyric Acid 1 1 1 1 4 4 NR 2 4 1 NR 1 3 1 1 1 Q 1 NR 4 3 NR NR NR
Cadmium Cyanide 3 1 1 1 Q 3 1 2 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Calcium Bisulfite 1 1 1 1 NR 3 1 2 4 1 3 1 4 1 1 Q 1 1 4 1 1 3
Calcium Chloride 4 1 1 1 1 4 3 1 2 1 1 Q 1 1 1 Q 1 1 1 1 1 1 3
Calcium Hypochlorite 1 1 1 1 4 3 2 3 4 1 NR 2 1 1 1 1 4 1 Q 1 NR 3
Calcium Nitrate 1 1 1 1 Q 3 1 2 1 1 3 1 1 1 1 1 1 1 1 1 1
Calcium Phosphate 1 1 1 Q 3 1 2 1 3 1 1 1 1 1 1 1 1 1 1
Calcium Sulfate 4 1 1 1 1 4 3 1 2 1 1 3 1 1 1 1 1 1 1 NR 1 1 3
Carbon Disulfide 4 1 1 4 Q NR NR NR 4 2 Q Q 1 1 1 1 1 1 NR 1 NR NR NR
Carbon Tetrachloride NR 1 1 1 Q 4 Q NR NR NR 3 1 1 1 1 1 1 1 1 Q 3 NR NR NR 3
Carbonic Acid 1 1 1 1 4 2 1 2 4 1 Q 1 1 1 1 1 1 1 4 1 1 1 1 3
Cellosolve 1 1 1 4 Q NR NR NR 2 1 4 1 1 1 1 1 1 NR NR Q Q 2
Chloroacetic Acid 1 1 1 4 NR 4 Q Q NR 1 Q 1 NR 1 1 1 1 1 NR NR Q 1 Q Q
Chlorine Water 1 1 1 1 NR 4 2 4 4 Q 1 NR Q 3 1 1 4 1 NR 1 1 NR NR 3
Chlorobenzene 3 1 2 4 NR NR NR 4 3 2 1 Q 1 1 1 1 1 1 NR 4 NR NR NR Q
Chloroform 1 1 1 Q 4 NR NR NR 2 4 1 Q 1 1 1 1 1 1 NR 3 NR NR NR Q
Chlorosulfonic Acid 4 1 NR 4 4 4 4 NR 2 NR NR 1 1 NR NR 1 NR NR NR NR NR NR
Chromic Acid up to 30% 1 1 2 4 NR 4 3 4 NR 3 NR NR NR 1 1 1 3 1 NR 1 Q 2 NR NR
Chromic Acid, 50% 1 1 2 4 NR NR 4 NR NR Q NR NR NR 1 1 1 NR 1 NR 1 Q 3 NR NR
Citric Acid 1 1 1 1 4 3 2 2 4 1 2 1 1 1 1 1 2 1 1 1 1 3
Copper Chloride 1 1 1 1 NR 3 1 2 4 1 NR NR NR 1 1 1 1 1 2 2 1 2 1 3
Copper Cyanide 1 1 1 1 NR 3 1 4 4 1 1 1 1 1 1 1 1 1 2 4 1 2 1 3
Copper Nitrate 1 1 1 1 4 3 1 2 4 1 1 1 1 1 1 1 1 1 1 1 1 3
22
Copper Sulfate 1 1 1 1 NR 3 1 2 4 1 NR 1 1 1 1 1 1 1 1 1 1 1 1 3
Cresol 3 1 2 1 Q NR NR Q 2 1 1 1 1 1 1 1 Q 1 NR NR NR
Cyclohexane 4 1 1 1 1 Q NR NR NR 2 1 1 1 1 1 1 1 1 1 1 1 NR NR NR
373
LINERS, RINGS
PLASTICS METALS and SEALS ELASTOMERS
A E P P E P P C P N R C 3 3 H T C N G. B V E H N C
B C T V T O V P O O Y A 0 1 A I E I U I P Y E O
F.
S T F D F L C V L R T R 4 6 S T R C N T D P O R
1. Good for 200F (93C) F E F E Y C Y Y O B T A A K A O M A P K
T
E E P L N O S S E N M E N L R -
2. Good for 185F (85C) (KYNAR) F
(TEFLON)
S R N T. T. L I I L N O E N
(HALAR)
(ETH. PROP.)
4. Good for 70F (21C) G
E P S S S O M E T
(M1 x M2)
Q Questionable R* Y T T T Y R R
(RULON)
NR Not recommended L E E E A I
No data available E E E E C P L
N L L L H E
E I
T
E
Decalin 1 1 Q NR Q NR 1 1 1 1 1 1 1 NR 1 NR NR Q
Detergents 1 1 2 1 Q 3 1 2 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Diesel Fuel 1 1 1 4 4 3 NR 4 2 1 1 1 1 1 1 1 1 1 1 1 NR 2 Q
Dowtherm 1 2 4 Q NR 1 NR 2 1 1 1 1 1 1 1 1 1 NR 1 NR 4 Q
Ethanolamine 1 NR 1 Q 3 3 3 1 1 1 1 1 1 1 1 1 1 Q Q Q 1 1
Ether 1 3 4 Q NR NR NR NR 1 1 1 1 1 1 1 1 1 NR NR NR NR Q
Ethyl Acetate NR 3 1 NR 4 4 NR NR Q 4 1 1 1 1 1 1 1 1 1 NR NR 4 NR NR NR
Ethyl Alcohol (Ethanol) 1 1 4 4 Q 3 4 1 1 1 1 1 1 1 1 1 2 NR 4 1 3
Ethylene Dichloride 4 1 1 Q Q NR NR 4 NR 3 1 1 1 1 1 1 NR 3 NR NR NR
Ethylene Glycol 1 1 1 1 4 4 Q 3 4 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3
Ferric Chloride 1 1 1 1 4 3 1 2 1 1 NR NR NR Q 1 1 NR 1 1 1 Q 1 3 3
Ferric Hydroxide 1 1 1 Q 3 1 2 1 3 2 1 1 1 1 1 4 1 1 1
Ferric Nitrate 1 1 1 1 4 3 1 2 4 1 3 3 1 1 1 1 1 1 1 1 1 3
Ferric Sulfate 1 1 1 1 4 3 1 2 4 1 Q NR Q 1 1 1 1 1 1 1 1 1 1 3
Ferrous Chloride 1 1 1 1 4 3 1 2 4 1 NR Q NR 1 1 1 1 1 1 1 1 1 1 3
Ferrous Sulfate 4 1 1 1 1 4 3 1 2 4 1 NR Q 1 1 1 1 1 1 1 1 1 1 Q
Fluoboric Acid 3 1 2 1 4 4 3 3 3 2 NR Q 3 NR NR 1 1 4 2 3 3 3 4
Fluosilicic Acid 1 1 1 1 Q 3 3 2 3 1 NR Q Q 2 NR NR 1 1 3 4 Q 1 1 3
Formaldehyde 3 1 3 1 4 4 NR 2 1 1 Q Q Q 1 1 1 1 1 NR NR Q 4 4 3
Formic Acid 1 1 1 4 NR NR Q 2 1 1 NR Q 1 1 1 1 3 Q NR Q 1 1 1 3
Freons (Fluorocarbons) NR 3 1 1 2 4 Q Q Q NR 4 1 1 Q 1 1 1 1 1 Q Q Q 1 1 3
Fuel Oils 1 1 4 4 Q NR 4 4 1 1 1 1 1 1 1 1 1 1 1 NR 4 1 3
Furfural 1 4 4 NR NR Q NR 1 1 1 3 1 1 1 1 1 NR NR Q Q Q Q
Gasoline NR 1 1 1 4 4 Q NR NR NR 1 1 1 1 1 1 1 1 1 4 1 NR Q Q 3
Glycerine (Glycerol) 1 1 1 4 4 4 2 2 4 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3
Heptane 1 1 1 3 4 4 2 4 4 1 1 1 1 1 1 1 1 1 1 1 NR 1 4 3
Hexane 1 1 1 3 4 4 2 4 NR 1 1 1 1 1 1 1 1 1 1 1 NR 1 4 3
Hydrobromic Acid, 20% NR 1 1 1 1 NR 4 2 2 4 3 NR NR NR 4 4 4 Q 1 NR 4 1 1 NR 3
Hydrochloric Acid, 0 - 25% NR 1 1 1 1 NR 4 2 3 3 3 NR NR Q 4 Q 4 4 1 Q 1 1 1 1 3
Hydrochloric Acid, 25 - 37% NR 1 1 1 1 NR 4 2 4 3 3 NR NR NR 4 Q Q Q 2 NR Q Q 3 4
Hydrofluoric Acid, 10% 1 1 1 1 NR 3 NR 2 4 3 NR NR NR 2 NR NR 2 NR 4 2 4 2 2 Q
Hydrofluoric Acid, 30% 1 1 1 1 NR 3 NR 3 NR 3 NR NR NR 3 NR NR 4 NR NR 3 4 2 3 Q
Hydrofluoric Acid, 50% 1 1 1 1 NR Q NR Q NR 3 NR NR NR 3 NR NR 4 NR NR 4 4 Q NR Q
Hydrogen Peroxide, 30% 3 1 1 4 NR 4 4 2 3 Q NR 1 Q 1 3 Q 1 1 NR 1 NR 1 Q 3
Hydrogen Peroxide, 50% 3 1 4 4 Q Q Q NR NR Q 1 Q Q NR NR NR 1 NR 1 NR 3
Kerosene 4 1 1 1 4 4 4 NR 4 NR 1 1 1 1 1 1 1 1 1 4 3 NR NR NR 3
Ketones NR 1 NR 4 4 NR NR Q NR 1 1 1 1 1 1 1 NR NR 2 NR NR Q
Lactic Acid 4 1 3 4 NR 4 4 1 1 NR NR 4 2 4 1 1 4 4 3 1 1 4 3
Lead Acetate 1 1 1 1 4 3 1 2 4 1 NR 1 1 1 1 1 1 1 4 NR 1 NR NR 3
Lubricants 1 1 1 2 4 3 1 2 NR 1 1 1 1 1 1 1 1 1 1 1 NR 3 Q 3
Magnesium Chloride 1 1 1 1 4 3 1 2 1 1 NR Q Q 1 1 1 1 1 1 1 1 1 1 3
Magnesium Hydroxide 1 1 1 1 Q 3 1 2 3 1 Q Q 1 1 1 1 1 1 3 1 1 1 1
Magnesium Nitrate 1 1 1 1 4 3 1 2 4 1 1 1 1 1 1 1 1 1 1 1 1 3
Magnesium Sulfate 1 1 1 1 4 3 1 2 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3
Methyl Alcohol (Methanol) 1 3 1 4 NR NR 4 4 1 1 1 1 1 1 1 1 1 4 NR Q 1 1 3
Methyl Chloride NR 1 1 Q NR NR NR NR NR 4 1 1 1 1 1 1 NR Q NR NR NR Q
Methyl Ethyl Ketone NR 3 1 NR 4 4 NR NR 4 NR 4 1 1 1 1 1 1 1 1 NR NR 1 NR NR Q
Methylene Chloride 4 1 Q NR NR NR NR NR 4 4 1 1 1 1 1 1 NR Q Q NR NR 3
Naphtha 4 1 1 1 4 4 4 Q 4 NR 1 1 1 1 1 1 1 1 1 4 3 NR NR NR 3
Nickel Chloride 1 1 1 1 4 3 2 2 4 1 NR NR Q 1 1 1 1 1 2 2 2 2 Q 3
Nickel Sulfate 1 1 1 1 4 3 2 2 4 1 NR NR 1 1 1 1 1 1 1 1 1 1 1 3
Nitric Acid, 10% 1 1 2 1 4 3 2 4 2 3 NR NR 1 2 1 Q 4 1 NR 1 Q 1 4 NR
Nitric Acid, 20% 1 1 3 2 4 3 3 4 3 Q NR Q 2 3 1 Q 4 1 NR 1 Q 3 Q NR
Nitric Acid, 50% 3 1 3 3 NR Q 4 Q 4 Q NR 1 3 4 2 Q Q 2 NR 3 Q Q Q NR
Nitric Acid (Concentrate) 3 1 NR 4 NR NR NR NR 4 Q NR 4 3 4 1 Q NR 1 NR 4 NR NR NR NR
Nitrobenzene 3 1 3 4 4 NR NR 4 NR 1 Q 1 1 1 1 1 1 1 NR Q 4 NR NR NR
Oil, Vegetable 1 1 1 1 4 3 Q 3 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Oil, Sour Crude 1 1 1 4 3 Q 4 NR 1 1 1 1 1 1 1 1 1 4 1 1 Q Q
22
Oleic Acid 1 1 1 1 4 4 Q 4 4 1 NR NR 3 3 1 1 1 1 Q 4 Q Q Q 3
Oxalic Acid 3 1 3 1 NR 4 1 3 4 1 4 4 3 4 1 1 1 4 1 2 2 4 3
374
LINERS, RINGS
PLASTICS METALS and SEALS ELASTOMERS
A E P P E P P C P N R C 3 3 H T C N G. B V E H N C
B C T V T O V P O O Y A 0 1 A I E I U I P Y E O
F.
S T F D F L C V L R T R 4 6 S T R C N T D P O R
1. Good for 200F (93C) F E F E Y C Y Y O B T A A K A O M A P K
T
2. Good for 185F (85C) E E P L N O S S E N M E N L R -
(KYNAR)
F
(TEFLON)
3. Good for 140F (60C) S R N T. T. L I I L N O E N
(HALAR)
E
(ETH. PROP.)
(TEFZEL)
4. Good for 70F (21C) T O L U C A N N I
E P S S S O M G E T
(M1 x M2)
Q Questionable R
R* Y T T T Y R
(RULON)
NR Not recommended A
L E E E I
No data available E E E E C P L
N L L L H E
E I
T
E
Perchloroethylene 1 1 Q Q NR NR NR 2 1 1 1 1 1 1 1 1 1 Q 1 NR NR NR
Phenol NR 3 1 3 4 NR NR 3 Q 2 1 Q 2 2 1 1 1 1 1 NR 1 Q NR NR Q
Phosphoric Acid, 0 - 50% 1 1 1 1 4 4 2 2 1 1 NR 1 3 1 4 1 1 1 Q 2 1 1 3 4
Phosphoric Acid, 50 - 100% 1 1 1 1 NR 4 2 2 1 1 NR NR Q 3 Q 1 1 1 NR 2 1 1 Q Q
Potassium Bromide 1 1 1 1 4 3 1 2 4 1 3 1 1 1 1 1 1 1 1 1 1 3
Potassium Carbonate 4 1 1 1 1 4 3 1 2 4 1 3 3 1 Q 1 1 1 1 1 1 1 3
Potassium Chlorate 1 1 1 1 4 3 1 2 4 1 3 3 1 1 1 1 Q 1 1 1 1 3
Potassium Chloride 1 1 1 1 4 3 1 2 4 1 1 NR Q 2 1 1 1 1 1 1 1 1 1 3
Potassium Cyanide 1 1 1 1 4 3 1 2 4 1 2 1 1 3 1 1 1 1 1 1 1 1 1 3
Potassium Dichromate 1 1 1 1 NR 3 1 2 1 1 1 3 1 1 1 1 Q 1 Q 1 1 3
Potassium Hydroxide 2 1 3 1 NR 2 2 2 4 1 Q 2 2 2 Q NR 1 1 4 NR 4 1 4 3
Potassium Nitrate 1 1 1 1 4 3 1 2 4 1 3 3 1 1 1 1 1 2 2 2 1 3
Potassium Permanganate 1 1 1 2 NR 3 1 3 1 1 Q 2 2 1 1 1 1 1 4 3 3 3 1 3
Potassium Sulfate 1 1 1 1 4 3 1 2 4 1 2 2 2 3 1 1 1 1 1 1 1 1 1 3
Propyl Alcohol 1 1 4 3 Q 4 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3
Silver Nitrate 4 1 1 1 1 Q 3 1 2 4 1 NR 1 1 1 1 1 1 1 4 1 1 1 1
Soaps 4 3 1 1 1 4 3 1 2 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 3
Sodium Acetate 1 1 1 1 4 3 1 2 4 1 1 NR 1 3 1 1 1 1 Q Q 1 1 Q Q
Sodium Bicarbonate 4 1 1 1 1 4 3 1 2 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 3
Sodium Bisulfate 4 1 1 1 1 4 3 1 2 4 1 NR NR 1 3 1 1 1 1 1 1 1 1 1 3
Sodium Carbonate 4 1 1 1 1 4 3 1 2 1 1 Q 1 1 3 1 Q 1 1 1 1 1 1 1 3
Sodium Chlorate 1 1 1 1 4 3 1 2 4 1 1 3 3 1 1 1 1 NR 1 1 1 1 3
Sodium Chloride 1 1 1 1 4 3 1 2 1 1 Q Q Q 3 1 1 1 1 1 1 1 1 1 3
Sodium Cyanide 1 1 1 1 4 3 1 2 4 1 Q 1 1 1 1 1 4 1 1 1 1 1 1 3
Sodium Hydroxide, 20% 4 1 1 2 1 NR 4 1 2 1 1 1 Q 1 1 1 NR 1 1 4 NR 1 1 1 3
Sodium Hydroxide, 50% 4 1 1 3 1 NR Q 2 2 1 3 Q 3 3 1 1 NR 1 1 4 NR 2 1 1 3
Sodium Hypochlorite, 5% NR 1 1 1 2 NR 3 1 3 1 1 Q Q NR 3 1 1 Q 1 Q 2 1 1 Q Q
Sodium Nitrate 1 1 1 1 4 3 1 2 4 1 1 1 3 1 1 1 1 4 4 1 1 1 3
Sodium Silicate 1 1 1 1 4 3 1 2 4 1 1 1 2 3 1 1 1 1 1 1 1 1 1 3
Sodium Sulfate 4 1 1 1 1 4 3 1 2 1 1 1 Q 1 1 1 1 1 1 1 1 1 1 1 3
Sodium Sulfide 4 1 1 1 1 4 3 1 2 1 1 1 Q 2 2 1 1 1 1 1 1 1 1 1 Q
Stannic Chloride 1 1 1 1 NR 3 1 2 4 1 1 NR NR 2 1 1 NR 1 1 1 Q 1 1 3
Sulfuric Acid, 0 - 10% 4 1 1 1 1 4 4 1 2 1 1 NR Q Q 1 4 1 1 1 4 1 1 1 Q 3
Sulfuric Acid, 10 - 75% NR 1 1 1 1 NR Q 1 3 1 4 NR NR NR 3 Q 2 2 2 NR 1 NR 4 NR Q
Sulfuric Acid (Concentrate) 4 1 Q 2 NR NR 4 Q 1 Q NR NR Q 3 NR 3 4 1 NR 2 NR Q NR
Sulfurous Acid 1 1 1 1 Q 4 2 2 1 1 NR NR 3 3 2 1 1 1 Q 1 NR 4 NR
Tannic Acid NR 1 1 1 1 Q 3 1 2 4 1 NR 2 2 2 1 1 1 1 NR 1 1 1 1 3
Tartaric Acid 1 1 1 1 4 3 1 2 4 1 Q Q 1 1 1 1 1 1 NR 1 4 1 1 Q
Tetrahydrofurane NR 1 2 4 NR NR NR NR 1 1 1 1 1 1 1 NR 4 NR NR Q Q
Toluene (Toluol) NR 3 1 2 2 4 NR NR Q NR 1 1 1 1 1 1 1 1 1 NR 3 NR NR NR 3
Trichloroethylene NR 1 1 1 Q NR NR NR Q NR NR 1 1 Q 1 1 1 1 1 NR 1 NR NR NR NR
Triethanolamine 4 1 NR 2 Q 3 Q 2 3 1 Q 1 1 1 1 1 1 1 Q NR Q 2 2
Turpentine 1 1 3 4 4 NR 4 4 1 1 1 1 1 1 1 1 1 3 1 NR 3 NR 3
Urea 1 1 1 NR 3 1 2 3 1 1 1 1 1 1 1 NR 1 1 1 Q Q
Vinegar 4 1 1 1 1 4 3 1 2 4 1 1 1 1 1 1 1 1 1 4 1 1 1 1 3
Water, Deionized 4 3 1 1 1 4 3 1 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1
Water, Sea (Salt) 4 1 1 1 1 4 3 1 2 1 1 NR NR Q 1 1 1 1 1 1 1 1 1 1
Xylene (Xylol) NR 3 1 2 1 4 NR NR Q NR 1 1 1 1 1 1 1 1 1 NR 1 NR NR NR 3
Zinc Chloride 1 1 1 1 NR 3 1 2 4 1 Q 2 1 1 NR 1 1 1 1 1 1 3
Zinc Sulfate 1 1 1 1 4 3 1 2 4 1 NR 1 1 2 1 1 1 1 1 1 1 1 1 3
* Polyester tested only at 80F (27C).
CAUTION
The data presented is based on information furnished by material formulations or may utilize proprietary additives. Therefore, users should
manufacturers. We assume no liability for its accuracy. It should be used only consult their chemical suppliers when considering the selection of equipment
as a guide and not as a guarantee of performance. Please remember that in materials and the materials should be tested under actual service condi-
22
any given application, many factors such as concentration, time, temperature tions.
and pressure influence chemical resistance. Also, in addition to changes
in conditions, be aware that different chemical suppliers utilize different
Registered trademarks: Noryl - General Electric;Ryton - Phillips Chemical; Kynar - Atochem;
Teflon, Tefzel - DuPont; Kalrez, Neoprene, Viton, Hypalon - DuPont Dow Elastomers;
Halar - Ausimont; Rulon - Dixon; Hastelloy - Haynes, International
375
CHEMICAL RESISTANCE GUIDE
FOR COMMON METAL FINISHING SOLUTIONS T-102L
ACCEPTANCE LEGEND P C P P N R P P E E 3 3 H H T C C G. S B S N E V H K
1 - Resistant to 200F (93C) V P P P O Y V T T C 0 1 A A I A E F. i U I E P I Y A
2 - Resistant to 180F (82C) C V P R T D F F T 4 6 S S T R R C N L O D T P L
C Y O F E E F T T A B A T A I P M O A R
(POLYPROPYLENE)
(HI-TEMP POLYPRO)
3 - Resistant to 160F (71C)
L N E S S E E N O M F C R N L E
(KYNAR)
4 - Resistant to 140F (60C)
(ETH. PROP.)
S S L L I N I E N O E O Z
(TEFLON)
5 - Resistant to 110F (43C)
(TEFZEL)
(HALAR)
L L U C N N N
(RULON)
6 - Resistant to 80F (27C) O O M E E
Q - Questionable Y Y
X - Not recommended
Without organic additives B C
COMMON PLATING PLASTICS METAL SEALS &
SOLUTIONS BUSHINGS ELASTOMERS
Alkaline Soak Cleaner (typical) 6 Q 3 2 2 4 X 1 1 1 1 1 1 1 1 3 3 3 1 6 6 6 2 6 1 1
Alkaline Electrocleaner (typical) 6 Q 3 2 2 4 X 1 1 1 1 1 1 1 1 3 3 3 1 6 6 6 2 6 1 1
Anodizing - Sulfuric Acid 5 2 4 3 3 3 2 1 1 1 X X 1 1 6 3 3 2 1 X X X 2 1 2 1
Anodizing - Chromic Acid 5 1 X X X 4 1 1 1 1 X X 2 6 3 3 3 2 1 X X X 6 1 2 1
Brass - Cyanide Copper / Zinc 6 X 3 2 5 3 X 1 1 1 3 3 1 1 1 3 4 2 1 6 6 6 2 X 3 1
Bronze - Cyanide Copper / Tin 6 X 3 2 5 3 X 1 1 1 3 3 1 1 1 3 5 2 1 6 6 6 2 X 3 1
Cadmium - Cyanide 6 6 3 2 5 3 X 1 1 1 3 3 1 1 1 3 5 2 1 6 5 6 2 X 3 1
Chromium - Hex, Decor & Hard 6 4
4 X X X 4 2 1 2 2 X X 6 4 1 6 3 2 1 X X X X 4 4 1
Chromium - Trivalent 5 4 6 5 6 4 1 1 1 1 X X 1 1 1 5 3 3 1 X 6 6 3 3 1 1
Copper - Cyanide 4 2 4 3 5 3 X 1 1 1 3 3 1 1 1 3 4 2 1 X 6 6 3 X 1 1
Copper - Pyro 6 5 3 2 4 4 6 1 1 1 4 4 4 4 1 3 5 2 1 X 6 6 3 6 1 1
Electroless Copper 6 5 5 4 5 4 X 1 1 1 X X X X X X 5 4 1 X X X 3 X 1 1
Copper Sulfate, Decor & PCB 5 3 4 3 5 2 1 1 1 1 X X X X 4 6 4 3 1 X X X 4 2 1 1
Copper Fluoborate 6 5 4 3 6 2 5 1 1 3 X X 6 6 X 6 Q 4 3 6 X 5 4 3 4 1
Gold - Acid 6 5 4 3 5 4 2 1 1 2 X 6 6 5 4 5 6 3 2 6 6 6 4 3 2 1
Gold - Neutral 6 5 4 3 4 4 3 1 1 2 6 6 6 5 2 4 5 2 1 6 6 6 4 3 2 1
Gold - Cyanide 6 5 4 3 5 4 X 1 1 2 6 6 6 5 2 5 5 2 1 6 6 6 4 4 3 1
Gold - Immersion 6 6 5 4 3 4 X 1 1 2 X X X X X Q 5 3 1 6 6 6 4 5 4 1
Nickel - Watts 4 2 3 2 4 2 2 1 1 1 X X 2 3 1 3 3 2 1 3 5 6 2 2 2 1
Nickel - Sulfamate 5 2 3 2 4 2 2 1 1 1 X X 2 3 1 3 3 2 1 3 5 6 2 2 2 1
Nickel - Woods 5 2 3 2 4 2 2 1 1 1 X X 3 4 3 3 3 2 1 6 6 6 3 2 2 2
Electroless Nickel * X 1* 5 4 6 4 1* 1 1 2 X Q X X Q Q 3 2 1 6 6 6 3 1 2 1
Palladium - Amine 6 X 5 4 6 5 Q 2 2 2 2 2 3 3 3 2 3 2 1 6 6 6 4 Q 3 2
Palladium / Nickel 6 5 4 3 3 2 5 1 1 1 X X 2 3 2 2 3 2 1 5 6 6 2 5 1 1
Rhodium 6 3 3 2 4 2 2 1 1 1 X X X X 6 3 3 2 1 3 6 6 3 2 1 1
Silver - Cyanide 6 6 4 3 5 3 X 1 1 1 X X X X X 3 3 2 1 6 6 6 3 Q 2 1
Tin - Sulfuric 5 4 4 3 3 3 2 1 1 1 X X X X X 3 3 2 1 6 6 6 3 2 1 1
Tin - MSA 6 5 4 4 6 4 2 1 1 3 X X X X 6 3 3 2 1 6 6 6 3 3 1 1
Tin - Alkaline X X 4 3 4 4 X 1 1 2 2 2 2 2 2 4 3 2 1 6 6 6 3 X 2 1
Tin / Lead 6 5 4 4 6 4 2 1 1 3 X X X X 6 3 3 2 1 6 6 6 3 3 1 1
Tin Fluoborate 6 5 4 3 6 2 4 1 1 3 X X 6 6 X 6 Q 3 1 6 X 5 4 3 4 1
Zinc, Acid Chloride 5 2 4 3 4 2 2 1 1 2 X X 6 5 2 3 3 3 1 X X 6 5 2 2 1
Zinc, Alkaline 4 Q 4 3 5 4 X 1 1 2 2 2 1 1 1 3 3 3 1 6 6 6 3 6 2 1
Zinc - Cyanide X 6 4 3 5 4 X 1 1 2 2 2 1 1 1 3 3 3 1 6 6 6 3 6 2 1
WET PROCESSING - PCB
Sodium Persulfate Microetch 6 4 4 5 6 3 4 1 1 2 X X X X X 3 3 2 1 X X X 4 3 2 1
Peroxide / Sulfuric Microetch 6 6 5 4 6 6 4 1 1 3 X X X X X 4 4 3 2 X X X 3 2 2 1
Black Oxide 6 Q 5 4 4 4 X 2 2 3 X X 6 6 1 6 X 5 1 X X X 6 X 3 1
Solvent Conditioner X X X X X X X 6 6 6 2 1 2 2 1 6 3 2 1 X X X X 6 3 1
Permanganate - Etch Back / Desmear X X X X X 6 5 2 2 3 6 2 2 2 1 5 3 2 1 X X X 2 5 3 1
Spray Etchant - Alkaline 5 5 4 3 5 5 5 1 2 3 X 6 5 4 2 4 4 3 1 X 6 6 4 6 3 2
Spray Etchant - Chloride 5 4 5 4 5 4 3 1 1 1 X X 6 4 2 4 4 3 2 X 6 6 5 3 2 1
Catalyst / Activator 5 4 6 5 6 5 4 3 1 2 X X X X X X 4 3 2 X X 6 5 4 3 2
Electroless Copper 6 5 5 4 5 4 X 1 1 1 X X X X X X 5 4 1 X X X 3 X 1 1
Photoresist Developer 5 4 4 4 5 4 6 1 1 1 1 1 1 1 1 4 4 3 2 6 6 6 4 6 2 1
Photoresist Stripper 6 5 4 4 4 4 X 1 1 1 1 1 1 1 1 4 4 3 2 6 6 6 4 X 2 1
COMMON ACIDS
Fluoboric Acid - 15% vol. 6 5 4 4 4 2 2 1 1 3 X X 6 6 X 6 6 5 3 6 X 6 3 2 2 2
Hydrochloric Acid - 30% vol. 6 3 5 4 3 3 1 1 1 1 X X 4 5 6 6 6 4 2 6 6 5 3 1 1 1
Nitric Acid - 50% vol. 6 6 6 6 6 6 4 3 1 3 X 6 6 5 2 X 6 3 2 X X X 6 3 3 2
Phosphoric Acid - 30% vol. 6 3 2 2 2 2 1 1 1 1 X 6 4 3 3 5 5 3 1 6 X 6 3 3 3 2
Sulfuric Acid - 15% vol. 6 4 4 4 5 2 1 1 1 1 X 6 2 3 4 4 3 3 1 6 6 6 3 2 1 1
Hydrofluoric Acid - 30% vol. 6 6 5 5 Q 3 2 1 1 2 X X 3 4 X 6 Q 3 2 Q X 6 5 3 3 2
COMMON ALKALIES
Sodium Hydroxide - 50% vol. 6 5 4 3 3 3 X 1 1 1 3 2 1 1 1 4 3 3 2 4 6 5 2 X 1 1
22
MATERIAL CODES
CORE NUMERICAL EXPONENTS INDICATE
FILTER MEDIA MATERIAL FOLLOWING CONCENTRATIONS
B - Natural Cotton 1. 1% 5. 30% 9. 80%
2. 5% 6. 40% 10. Dilute
C - Bleached Cotton 1, 2
3. 10% 7. 50% 11. 96%
G - Glass Fiber A - 304 stainless steel 4. 20% 8. 5 to 80% 12. Fuming
H - Hi Perf
K - Polyester (Dacron) S - 316 stainless steel OK - Acceptable to use media to its maximum
recommended operating temperature.
N - Nylon Number - Maximum recommended operating
T - Tinned steel
O - Acrylic (Orlon) temperature (F).
P - Polypropylene, Fibrillated 1, 2 U - Polypropylene NR - Not recommended.
R - Rayon 1
Meets FDA regulations for potable water
2
Free of "sizing" and yarn "finish" substances
U - Polypropylene
W - Polypropylene 1, Potable Water
Dacron and Orlon are registered trademarks of DuPont.
B&C G H K N O P, U & W R
Media Core Media Core Media Core Media Core Media Core Media Core Media Core Media Core
Acetaldehyde 200 S,A
Acetic acid, 20% 85 135U,S,A OK S 1008 100U,S,A 2002 140U,S,A OK8 130U,S,A OK 135U,S,A OK2 135U,S
Acetic acid, glacial 70 135U,S,A OK S 70 70U,S,A 200 140U,S,A OK 130U,S,A 150 135U,S,A 70 70U,S,T
Acetic anhydride NR NR NR NR NR NR 65 NR NR 70 135U,S,A,T
Acetone OK 80U,S,A,T OK S NR NR OK 80U,S,A,T OK 65U,S,A,T OK S,A,T 70 70U,S,A,T OK S,A,T
Aluminum chloride 1302 130U,S,A 702 70U,S,A 702 70U,S,A 653 80U,S,A,T 702 70U,S,A 1952 135U,S,A 1302 130U,S,A
Aluminum fluoride NR2 NR NR2 NR 653 65U,S,A 1352 135U
Aluminum sulfate 70 70U,S,A NR NR 65 65U,S,A 65 65U 70 70U,S,A 175 135U,S,A NR5 NR
Ammonia, aqueous NR NR NR NR NR NR 65U,S,A 100 S,A,T
Ammonium carbonate OK3 140U,S,A 1203 OK3 135U,S,A
Ammonium chloride 703 70U NR3 120U,S,A 1353 135U
Ammonium hydroxide 1005 100U,S,A NR NR 655 65U,S,A 1005 NR 1955 135U,S,A 70 70U,S,A
Ammonium nitrate 1002 100U,S,A OK2 140U,S,A,T 652 65U,S,A,T OK2 100U,S,A OK2 140U,S,A,T OK2 135U,S,A,T 1002 S,A,T
Ammonium phosphate 65 65U,S,A NR 130U,S,A,T 135 135U,S,A
Ammonium sulfate 652 65U,S,A,T 1952 NR OK2 195U,S,A,T
Amyl acetate 200 S,A,T 70 S,A,T NR NR 65 S,A,T 70 S,A,T NR NR OK S,A
Amyl alcohol 200 S,A,T 65 S,A,T 195 S,A,T 65 S,A,T OK S,A,T
Aniline NR NR 65 S,A,T 175 S,A,T
Aqua regia NR NR NR NR NR S,A,T 70 70U
Arsenic acid NR NR OK S 100 100U,S,A NR NR NR NR 70 70U,S,A OK 95U,S,A
Barium hydroxide NR
Barium chloride
Barium sulfate
Benzaldehyde
Benzene (benzol) OK S,A,T OK S,A NR NR 65 S,A,T OK S,A,T 65 S,A,T NR NR OK S,A,T
Benzene sulfonic acid
Benzoic acid
22
B&C G H K N O P, U & W R
Media Core Media Core Media Core Media Core Media Core Media Core Media Core Media Core
Butyl acetate OK U,A,T OK S OK S,A 65 S,A OK S,A OK S,A 195 S,A
Butyl alcohol OK 140U,S,A,T OK S OK S,A,T 65 65U,S,A,T OK 130U,S,A,T OK S,A,T 65 65U,S,A,T
Butyl amine
Butyl phthalate
Butyric acid 70 70U,S,A 195 70U,S,A NR NR 65 65U,S,A
Cadmium cyanide 200 140U,A,T NR NR OK 140U,A,T NR NR OK 135U,A,T 140 140U,A,T
Calcium bisulfite
Calcium chloride NR NR OK S 195 S NR NR OK S OK S NR NR
Calcium hypochlorite NR NR NR NR 140 140U NR NR NR NR 135 135U
Calcium nitrate NR NR
Calcium phosphate
Calcium sulfate
Carbon disulfide 70 S,A,T 65 S,A,T NR NR 65 S,A,T 65 S,A,T NR NR
Carbon tetrachloride OK 100U,S 100 S OK S 65 U,S OK 100U,S OK S 95 95U,S OK 95U,S
Carbonic acid 100 100U,S 100 S,A NR NR 95 95U,S,A 100 S,A OK 135U,S,A 100 100U,S,A
Cellosolve NR NR NR NR NR NR
Chloroacetic acid NR NR NR NR NR NR 70 70U
Chlorine water NR NR NR NR NR NR NR NR
Chlorobenzene 195 S,A OK S 195 S,A 195 S,A 195 S,A 195 S,A NR NR 195 S,T
Chloroform OK 65U,S,A OK 70U,S,A 65 65U,S,A NR NR OK 70U,S,A 70 70U,S,A OK S,A
Chlorosulfonic acid NR NR NR NR
Chromic acid up to 30% NR NR NR NR NR NR
Chromic acid, 50% 95 S NR NR NR NR
Citric acid 135 135U,S,A OK S,A NR NR 65 65U,S,A NR NR OK S,A OK 135U,S,A 150 140U,S,A
Copper chloride
Copper cyanide NR NR NR NR OK 135U,S,A 135 135U,S,A
Copper nitrate NR NR
Copper sulfate 135 135U,S OK S,A OK 130U,S,A 65 65U,S,A NR NR OK 130U,S,A OK 135U,S,A 135 135U,S,A
Cresol OK S 80 U 70 S 65 S NR NR 185 S
Cyclohexane 65 S,A,T NR NR 65 S,A,T 195 S,A,T NR NR NR NR 65 S,A,T
Decalin NR NR
Detergents
Diesel fuel OK 115U,S,A,T OK S,A OK S,A,T 65 65U,S,A,T OK 120U,S,A,T NR NR 120 120U,S,A,T OK S,A,T
Dowtherm 65 65U,S,A,T OK S,A 70 70U,S,A,T
Ethanolamine 65 65U,S,A,T 70 70U,S,A,T
Ether OK S,A,T OK S,A OK S,A,T 65 S,A,T NR NR NR NR
Ethyl acetate OK 115U,S,A,T OK S,A 65 S,A,T 65 65U,S,A,T NR NR 120 120U,S,A,T 65 S,A,T
Ethyl alcohol (ethanol) OK 120U,S,A,T OK S OK 135U,S,A,T OK 135U,S,A,T OK S,A,T
Ethylene dichloride
Ethylene glycol OK 120U,S,A,T OK S,A OK 70U,S,A,T OK 135U,S,A,T 651 65U,S,A,T 70 70U,S,A,T OK 140U,S,A,T OK S,A,T
Ferric chloride NR NR 140 U 95 95U,S,A,T 140 140U 652 65U 195 130U,S,A,T OK 135U & S NR NR
Ferric hydroxide NR NR NR NR
Ferric nitrate NR NR NR NR 65 65U & S 70 70U & S OK 135U & S NR NR
Ferric sulfate 652 65U,S,A OK S,A NR2 NR 652 65U,S,A 65 65U,S,A 702 70U,S,A OK2 135U,S,A
Ferrous chloride NR NR NR NR 65 65U 65 65U 65 65U OK 135U 65 65U
Ferrous sulfate NR NR NR NR
Fluoboric acid NR NR NR NR
Fluosilicic acid NR NR NR NR 70 70U
Formaldehyde 70 70U,S,70A&T OK S,A OK 130U,S 653 65U&A,S 653 65U&A,S 65 65U&A&S OK3 135U,S 653 65U,A,T
Formic acid NR3 NR OK S,A OK3 140U& A OK10 135U,150A NR NR 100 3
100U&A OK 135U,70A NR NR
Freons (fluorocarbons) 200 S,A,T OK S,A OK S,A,T 95 S,A,T OK S,A,T 70 70U,S,A,T 195 S,A,T
Fuel oils OK S,A,T OK S,A,T OK S,A OK S,A,T OK S,A,T 70 S,A,T OK S,A,T
22
B&C G H K N O P, U & W R
Media Core Media Core Media Core Media Core Media Core Media Core Media Core Media Core
Hydrofluoric acid, 10% 70 70U NR NR 140 140U 65 65U NR NR 140 140U OK 135U 65 65U
Hydrofluoric acid, 30% NR NR NR NR
Hydrofluoric acid, 50% NR NR NR NR 70 70U 65 65U 70 70U 70 70U NR NR
Hydrogen peroxide, 30% NR NR OK S,A 100 65U,S,A 65 65U,S,A NR NR 100 65U,S,A 1402 140U,S,A 1002 95U,S,A
Hydrogen peroxide, 50% NR NR OK S,A 652 65U NR NR 705 70U,S,A NR5 NR
Kerosene OK 65U OK S,A NR NR OK 65U,S,A,T OK 65U,S,A,T OK S,A,T 65 65U,S,A,T OK S,A,T
Ketones
Lactic acid NR NR 140 U OK 140U 65 65U 65 65U OK 140U OK 135U 65 65U
Lead acetate OK 135U
Lubricants OK 65U,S,A,T OK S,A,T OK 65U,S,A,T OK S,A,T 70 70U,S,A,T OK S,A,T
Magnesium chloride 65 65U,S NR NR 65 65U,S 65 65U,S 70 70U,S 175 135U,S 65 S
Magnesium hydroxide 65 65U,S OK 135U,S
Magnesium nitrate
Magnesium sulfate 65 65U,S,A 165 135U,S,A 65 65U,S,A
Methyl alcohol (methanol) OK 120U,S,A,T OK S,A OK U,S,A,T OK U,S,A,T OK U,S,A,T OK U,S,A,T OK U,S,A,T OK U,S,A,T
Methyl chloride 95 212S & A NR NR
Methyl ethyl ketone OK 130U,S,A,T OK S NR NR 65 65U,S,A,T OK 140U,S,A,T OK S,A,T 140 140U,S,A,T OK 140U,S,A,T
Methylene chloride OK 200S&A,95T 212 S,A NR NR 95 95S,A,T 95 212S & A OK 212S & A NR NR
Naphtha OK 65U,S,A,T OK S,A OK S,A,T 65 65U,S,A,T OK 65U,S,A,T OK S,A,T 65 65U,S,A,T OK 70U,S,A,T
Nickel chloride 70 70U 140 U OK 70U 65 65U NR NR 70 70U 140 140U 95 95U
Nickel sulfate 70 70U,S,A OK S,A OK 70U,S,A 65 65U,S,A NR NR 70 70U,S,A OK 135U,S,A 95 140U,S,A
Nitric acid, 10% 70 70U,S,A OK S,A OK 130U,S,A 205 130U,S,A NR NR 200 130U,S,A OK 135U,S,A 65 140U,S,A
Nitric acid, 20% NR NR 250 S,A OK 130U 65 65U 145 130U 135 135U NR NR
Nitric acid, 50% NR NR 250 S,A 70 70U 65 65U 70 70U 70 70U & A NR NR
Nitric acid (concentrate) NR12 NR 125 S,A NR12 NR NR12 NR NR12 NR NR12 NR NR NR
Nitrobenzene NR NR NR NR 195 70U,S 195 U,S 195 70U,S 70 70U,S,A 195 S
Oil, vegetable OK 90U,S,A,T NR NR 65 65U,S,A,T NR NR NR NR 70 70U,S,A OK 100U,S,A
Oil, sour crude 140 65U,S,A,T OK S,A,T OK 65U,S,A,T OK 65U,S,A,T OK S,A,T 70 70U,S,A,T OK 70U,S,A,T
Oleic acid 70 70U,S OK2 70U,S 652 65U,S NR2 NR 702 7OU,S 1802 135U,S 952 140U,S
Oxalic acid NR NR OK 65U,S,A NR2 NR NR2 NR 65 65U,S,A 1802 135U,S,A 952 140U,S,A
Perchloroethylene OK 65U,S,A,T OK S,A,T OK 65U,S,A,T OK S,A,T OK S,A,T 70 65U,S,A,T OK S,A,T
Phenol OK 65U,S NR NR NR NR NR NR 65 65U,S 205 S
Phosphoric acid, 0-50% 703 70U,S,200A 212 A OK3 210A,S 2053 205A 653 65U&A, S 2103 210A,S 180 135U,212A 1351 135S & A
Phosphoric acid, 50-100% NR NR 140 U OK9 140U NR7 NR 1509 140U 1359 135U 653 65U & A
Potassium bromide NR NR NR NR
Potassium carbonate NR NR
Potassium chlorate NR NR NR NR
Potassium chloride 702 135U,S,A NR2 NR 652 65U,S,A 652 65U,S,A 1752 135U,S,A 652 140U
Potassium cyanide OK2 120U,S,A OK 135U,S,A NR2 NR OK2 135U,S,A OK2 S,A
Potassium dichromate NR NR NR NR
Potassium hydroxide OK2 120U,S,A NR NR OK2 130U,S,A 1202 120U,S,A OK2 140U,S,A 1952 130U,S,A OK2 135U,S,A OK2 140U,S,A
Potassium nitrate NR NR NR NR
Potassium permanganate NR2 NR NR2 NR 1402 135U,S,A NR2 NR
Potassium sulfate 702 70U,S,A NR2 NR 652 65U,S,A NR2 NR 1702 135U,S,A 652 65U,S,A
Propyl alcohol OK 120U 70 65U,S,A,T
Silver nitrate NR NR OK S,A OK 130U,S,A NR NR NR NR OK 130U,S,A OK 135U,S,A NR NR
Soaps 185 135U,S,A
Sodium acetate 65 65U,S,A 65 65U,S,A OK 135U,S,A 65 65U,S,A
Sodium bicarbonate 65 65U,S,A,T NR NR 65 65U,S,A,T 135 135U,S,A OK 135U,S,A 65 65U,S,A
Sodium bisulfate NR NR NR NR 65 65U 70 70U 135 135U NR NR
Sodium carbonate 65 65U,S,A 65 65U,S,A 65 65U,S,A OK 120U,S,A 65 65U,S,A 170 135U,S,A
Sodium chlorate NR NR 65 65U,S,A 170 135U,S,A
Sodium chloride OK 120U OK3 140U OK3 140U OK3 140U OK 140U OK3 135U OK3 140U
22
B&C G H K N O P, U & W R
Media Core Media Core Media Core Media Core Media Core Media Core Media Core Media Core
Sodium sulfide 65 65U,S NR NR 65 65U,S 135 135U,S 170 135U,S 65 65U,S
Stannic chloride 65 65U 652 65U 652 65U 702 70U 652 65U
Sulfuric acid, 0-10% 1002 100U,S OK S 1452 145U,S 1402 140U,S 1452 145U,S OK3 135U,S 1002 100U,S
Sulfuric acid, 10-75% NR7 NR OK S 657 65U NR11 NR NR NR 657 65U 1357 135U NR11 NR
Sulfuric acid (conc.) NR12 NR 100 S NR12 NR NR12 NR NR NR NR12 NR 6511 65U,S,A NR12 NR
Sulfurous acid NR NR 140 U OK 135U NR NR NR NR OK 135U 135 135U
Tannic acid 65 65U,S,A OK S,A OK 135U,S,A 653 65U,S,A 653 65U,S,A OK 135U,S,A OK 135U,S,A 135 135U,S,A
Tartaric acid 65 65U,S NR NR 65 65U,S 135 135U,S 145 135U,S
Tetrahydrofurane 65 65U,S,A OK S,A NR NR 65 S,A 95 70U,S,A NR NR 70 65U,S,A OK3 70U,S,A
Toluene (toluol) OK 110U,S,A OK S,A NR NR 65 65U,S,A,T OK 120U,S,A,T OK S,A,T 120 110U,S,A,T OK S,A,T
Trichloroethylene OK S,A NR NR 65 S,A 65 65U,S,A OK S,A NR NR OK S,A
Triethanolamine 65 65U,S,A,T 65 65U,S,A,T 70 65U,S,A,T
Turpentine OK 65U,S,A,T OK S,A 95 S,A,T 65 65U,S,A,T OK S,A,T OK S,A,T 70 65U,S,A,T OK S,A,T
Urea 70 T 65 T
Vinegar 95 95U,S,A NR NR NR NR NR NR 135 135U,S,A 100 100U,S,A
Water, deionized OK U,S
Water, sea (salt) OK 120U 140 U OK 135U 140 140U 135 135U 240 135U OK 135U 140 140U
Xylene (xylol) OK S,A,T NR NR OK S,A,T OK S,A,T OK S,A,T NR NR OK S,A,T
Zinc chloride 120 120U
Zinc sulfate OK S,A NR NR NR NR OK U,S,A OK U,S,A
22
BULLETIN INDEX 380
C-112 Series HF plastic cartridge lter 250-251 F-601 Series CB cartridge/bag ltration 348-349
chambers systems
C-113 Series GC plastic cartridge lter 243-244 F-701 Series DF ltration systems 343-346
chambers F-703 Roll-a-Filter 347
C-114 Series GH-HP plastic cartridge 245-247
lter chambers F-705 Recessed plate lter press 350-351
381
P-108 Series HCI & HSS metal 180-182 P-630 Series S self-priming centrifugal 219-222
horizontal pumps pumps
P-109 Series RC horizontal pumps 185-186 P-631 Series I self-priming centrifugal 223-224
pumps
P-111 Series HN horizontal pumps 170-171 P-632 Series T self-priming centrifugal 225-226
P-112 Series HT horizontal pumps 183-184 pumps
P-200 Portable dolly & mixing tank 97 R
R-102 Carbon purication chambers 357-358
P-201 Series HE horizontal pumps 172-175
R-103 Carbon purication systems 359-360
P-203 Series HC & HK horizontal pumps 167-169
R-201 Ion exchange chambers & 367-370
P-206 Series HH horizontal pumps 163-164 systems
P-207 Series HA horizontal pumps 176-179 R-208 Ion exchange resins 371
P-300 Series E vertical pumps 132-133 SB
P-301 Series EH vertical pumps 137-140 SB-33 Safety rst 5
P-302 Series HB vertical pumps 149-152 T
P-303 Series B vertical pumps 153-156 T-102 General chemical resistance guide 373-374
P-307 Series ECI & ESS metal vertical
pumps
157-159 TM
TM-110 Chemical resistance guide for lter 375-378
P-309 Series EHM vertical pumps 141-144 media
P-312 Series EO molded vertical pumps 134-136 TP
P-313 Series TM-V vertical pumps 145-146 TP-103 Npsh net positive suction head 120
P-314 Series TM-VT
VT vertical turbine 147-148 TP-106 General notes on pump selection 119
pumps
TP-107 Drum pump chemical resistance 68-71
P-402 Series DP drum pumps 47-54 guide
22
P-404 Series HP hand dispensing pump 65-67 TP-112 Tips for the proper selection of 122
P-411 High viscosity drum pumps 58-64 seals used in horiz. Pumps
TP-113 Vertical pumps 121
P-412 Smart drum pump batch control 55-57
system TP-119 Continuous or batch clarication 231
in-line or recirculatory
PRODUCT INDEX 382
A E
Activated carbon . . . . . . . . . . . . . . . . . . . . . . . . . .21-24, 358 Eductors, tank mixing . . . . . . . . . . . . . . . . . . . . . . . . . . .89-92
Adapters, hose barbs . . . . . . . . . . . . . . . . . . . . . 54,111-114 Electric heating devices. . . . . . . . . . . . . . . . . . . . . . . . 98-109
Aftercoolers, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-45 Electric motor starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Agitators, uid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89-95 Electrodes, pH & ORP . . . . . . . . . . . . . . . . . . . . . . . . . . 72-79
Air lter/dryers for compressed air . . . . . . . . . . . . . . . .42-45 Extractors, grease, oil, etc. . . . . . . . . . . . . . . . .117, 361-364
Air operated diaphragm pump . . . . . . . . . . . . . . . . . . . 35-40
Amp-hour/minute meters . . . . . . . . . . . . . . . . . . . . . . . .83-84 F
Automatic ltration systems . . . . . . . . . . . . . . . . . . . 337-342 Fabrics, lter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345, 347
Filter chambers:
B Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-45
Bag ltration chambers . . . . . . . . . . . . . . 256-259, 272-275 Bag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256-259, 272-275
Bag ltration systems . . . . . . . . . . . . . . . .272-276, 302, 317 Carbon purication . . . . . . . . . . . . . . . . . . . . . . . . .357-358
Bag ltration systems, hanging. . . . . . . . 291-292, 348-349 Cartridge . . . . . . . . . . . . . . . . . . . . . . . . .232-255, 266-278
Bags, lter . . . . . . . . . . . . . . . . . . . . 257, 259, 276, 292, 349 Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258-261
Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266-278
C Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232-261
Carbon, activated . . . . . . . . . . . . . . . . . . . . . . . . . 22, 24, 358 Filter media:
Carbon purication chambers . . . . . . . . . . . . . . . . . 357-358 Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-45
Carbon purication media . . . . . . . . . . . . . . . . . . 21-24, 358 Bags . . . . . . . . . . . . . . . . . . . . . . . 257, 259, 276, 292, 349
Carbon purication systems . . . . . . . . . . . . . . . . . . .359-360 Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21-24, 358
Cartridge/bag ltration systems . . . . . . . . . . . . . . . .348-349 Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-30
Cartridges, lter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30 Cloth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345, 347
Chambers: Discs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261, 263, 323
Bag lter . . . . . . . . . . . . . . . . . . . . . . . . .256-259, 274-275 Resin, ion exchange . . . . . . . . . . . . . . . . . . . . . . .369, 371
Carbon purication . . . . . . . . . . . . . . . . . . . . . . . . 357-358 Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345, 347
Cartridge . . . . . . . . . . . . . . . . . . . . . . . . 232-255, 266-278 Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258-261 Filter press:
Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266-278 Laboratory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352
Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232-261 Recessed plate . . . . . . . . . . . . . . . . . . . . . . . . . . . .350-351
Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131 Filtration systems:
Chemical resistance guides . . . . . . . . . . . . .68-71, 372-278 Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .337-340
Clamps & bands: Backwash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341-342
Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114 Bag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272-276, 302, 317
Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114 Bag, hanging . . . . . . . . . . . . . . . . . . . . . 291-292, 348-349
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114 Cartridge . . . . . . . . . . . . . . . . 279-290, 293-321, 324-336
Cleaners, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-45 Disc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322-323, 328-331
Cloth, non-woven . . . . . . . . . . . . . . . . . . . . . . . . . . . .345, 347 Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343-347
Coalescers, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-45 Fittings:
Coalescing media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364 Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114
Coalescing systems, oil/water separation . . . . . . . 361-364 Pipe, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114
Collection and pumping stations for liquids . . . . . . 160-162 Floats:
Conductivity controllers . . . . . . . . . . . . . . . . . . . . . . . . . 80-82 Liquid level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-126
Controllers & regulators: Sump pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-126
Electroplating brightener . . . . . . . . . . . . . . . . . . . . . . 83-84 Floor mats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Liquid level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-126 Flow meters, controllers, sensors . . . . . . . . . . . . . . . . .85-88
pH & ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72-79
Coolers, compressed air . . . . . . . . . . . . . . . . . . . . . . . . 42-45 G
Couplings: Gravity lters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343-347
Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114
Quick-connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111-114 H
Hand pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65-67
D Heat exchanger coils . . . . . . . . . . . . . . . . . . . . . . . . 107-109
Dehumidifying equipment . . . . . . . . . . . . . . . . . . . . . . . 42-45 Heaters:
Dewatering equipment . . . . . . . . . . . . . . . . . . . . . . . .350-352 Electric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98-109
Diaphragm pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-40 Immersion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98-109
Dispersion systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89-95 Hose:
22
"SIR FILCO"
INTERNATIONAL
SERFILCO EUROPE, Ltd. SERVICE FILTRATION of CANADA, Ltd.
Broadoak Industrial Park, Ashburton Rd. 4141 Sladeview Crescent, Units 12 & 13
West, Trafford Pk. Manchester M17 1RW England Mississauga, Ontario, Canada L5L 5T1
Tel: +44 (0)161-872-1317 Tel: 905-820-4700 or
FAX: +44 (0)161-873-8027 800-565-5278 (Canada only)
e-mail: sales@serfilco-europe.com FAX: 905-820-4015
www: serfilco-europe.com e-mail: sales@service-filtration.com
www: service-filtration.com
SERFILCO GmbH
Promenade 5, D-52076 Aachen, Germany SERFILCO ASIA
Tel: +49 (0)2408-928523 64/II, KHYABAN-E-SHUJAAT, PHASE V, D.H.A
FAX: +49 (0)2408-928528 KARACHI, PAKISTAN
e-mail: ralf.teichmann@serfilco.de Tel: 92-21-534-6165
www: serfilco-europe.com FAX: 92-21-534-5964
Cell: 92-300-392-8807
SERFILCO France, sarl e-mail: amalik@serfilco.com
34, Avenue des Champs Elysees
75008 Paris, France
Tel: +33 (0)1-44-95-37-66
FAX: +33 (0)1-48-86-97-36
e-mail: drougeau@club-internet.fr
www: serfilco-europe.com