R ANT Y The Philips BV Pulsera C-Arm is a multi-application

mobile X-ray imaging system for the most challenging






interventional procedures in Pain Management,




S OM

General, Orthopedic, Vascular, Neurovascular and



N

Cardiac surgeries. The Philips BV Pulsera is a powerful


I


Y,


TE



L OG

fluoroscopy system with a high resolution CCD camera,


outstanding image quality with low X-ray dosage, crisp,
clear images and superior penetration power.

Soma Technology Inc. 166 Highland Park Drive Bloomfield, CT 06002 USA
Phone: 1.800.GET.SOMA www.SomaTechnology.com Email: soma@somatechnology.com

Typical manufacturers specifications and images Revised 9/20/2012


Philips BV Pulsera C-Arm
X-Ray System Pulsed Fluoroscopy Mode Video Camera
Half Dose Fluoroscopy High resolution CCD camera
Specialty Packages Available Quarter Dose Fluoroscopy 525 line/frame
Extended processing Focal spot: 0.6 mm Full frame capture
Vascular functions kVp range: 40 120 kVp 360 motorized rotation
Extended vascular functions mA range: 0.4 12 mA Left-right image reversal
Cardiac Pulsed functions P ulse rate: 6.25 or 12.5 pulses per Top-bottom image reversal
second Negative mode
Generator Pulse width: 11 to 37 milliseconds Computer controlled features: (optional)
80 kHz High frequency C omputer controlled APF, mA, kVp and - Gain
7.5 kW full-wave camera gain - Blanking
Up to 120 kVp - Camera iris
Up to 60 mA for radiographic film Pulsed Fluorography Mode
exposures Focal spot: 0.6 mm Video Monitors
Continuous fluoro boost mode up to 20 kVp range: 40 110 kVp Dual 17 in high resolution, anti-glare,
mA mA range: Up to 60 mA anti-static
Pulsed fluoro mode P ulse rate: 3 to 30 pulses per second Ambient room light sensor
Pulsed fluorography mode up to 60 mA (optional) Multi-LED X-ray ON indicator
Full power from outlet: P ulse width: 8.0 / 9.5 / 11.1
- 50 Hz or 60 Hz milliseconds Hardcopy Options
- 100V-20A to 240V-10A C omputer controlled camera iris, mA, Thermal printer (optional)
kVp, & camera gain DICOM (optional)
X-Ray Tube Image Capture Device (optional)
Rotating anode X-ray tube Digital Exposure Mode Laser aiming device (optional)
Focal spots: 0.3 mm and 0.6 mm Focal spot: 0.6 mm
Anode heat capacity: 300,000 HU kVp range: 40 110 kVp C-Arm Dimensions
Anode cooling rate: 70,000 HU/min mA range: 1.0 75 mA Height: 71 / 91 in (1805 / 2305 mm)
Housing heat capacity: 1,900,000 HU Width: 35 in (880 mm)
Anode diameter: 2.8 in Radiographic Mode Length: 76 in (1930 mm)
Anode angle: 10 Focal spot: 0.6 mm Weight: 695 lbs 315 kg
kVp range: 40 120 kVp
Collimator Fixed 60 mA Workstation Dimensions
Iris collimation with dual opposing lead 0.6 mm - mAs range: 3.2 125 mAs Height: 69 in (1760 mm)
shutters allowing elliptical, round and Width: 32 in (800 mm)
rectangular collimation Video Imaging System Depth: 37 in (925 mm)
Minimum beam size < 5 X 5 cm2 Image Intensifier
Iris and shutters are continuously
variable 9 in Image Intensifier
All functions remotely controlled from Tri-mode 9 in/7 in/5 in image intensifier
the C-Arm control panel - 9 in.: 1.6 lp/mm
- 7 in.: 2.1 lp/mm
Fluoroscopy Mode - 5 in.: 2.9 lp/mm
Focal spot: 0.3 mm and 0.6 mm DQE: 65% (typical)
kVp range: 40 120 kVp
mA range: 0.1 10 mA Low Dose 12 in Image Intensifier (optional)
fluoro mode Tri-mode 12 in/9 in/7 in image
mA range: 0.2 20 mA continuous High intensifier
Definition fluoro boost mode - 12 in.: 1.2 lp/mm
Auto and manual modes - 9 in.: 1.4 lp/mm
Continuous or Pulsed operation - 7 in.: 2.0 lp/mm
APF varies mA, kVp and camera gain DQE: 65% (typical)
User specific APF tables

Soma Technology Inc.


166 Highland Park Drive
Bloomfield, CT 06002 USA
1.800.438.7662
www.SomaTechnology.com

Note: The technical data given in this publication is for general information and is subject to change without notice. Actual configuration
on the unit may vary. Contact our sales representatives for a complete list of details.

You might also like