You are on page 1of 3

ANNUAL LABORATORY TEST REPORT

COMPOUND: Sevrene 3000-60A ANNUAL REPORT DATE: 02/05/14


COLOR: N/A ORIGINAL LABORATORY REPORT DATE: 7/13/09
SPECIFICATION: WSS-M2D510-A6 PAGE: Page 1 of 3

DATA REPRESENTS ACTUAL LABORATORY TESTS AND REMAINS CURRENT FOR ONE YEAR

Test
Freq. Test Method Spec. Range Results

Fogging, (SAE J1756, 3 h at 100C heating, 70% min. 1 h 76%


21C Cooling Plate, post test conditioning 16 h 91%
1 h and 16 h)

Odor, (FLTM BO 131-01), max. Rating 2 1.3 dry


1.0 wet

Flammability, (ISO 3795/SAE J369) 100 mm/minute 26 mm/min.


Burn Rate, max.

Low Temperature Brittleness No Cracking Pass


(ISO 812, Type B Specimen / ASTM D2187,
Method A), at -30C* **

Colorfastness to Burnt Gas, 168 hours at 60C Rating 4 Rating 4-5


(ISO 105-A01/AATCC Procedure 1), min.

Fade Resistance:

Accelerated Xenon Weathering, min. Rating 4 Rating 4-5


(FLTM BO 116-01, Filtered Xenon 2406.4 kJ/m2, (Black)
ISO 105-A01/AATCC Procedure 1,
Test performed SAE J1885, 1240.8 kJ/m2

Florida Weathering under Glass, min. Rating 4 min. Rating 4-5


(FLTM BI 160-01, under glass, (Black)
5 South direct, backed, 12 months,
AATCC evaluation procedure 1)* **

Soiling and Cleanability of Interior Trim, max.


(FLTM BN 112-08, ISO 105-A02/AATCC
Evaluation Procedure 1)
NLGI 2 Grease Rating 3 Rating 5
Orange Juice (not from concentrate) Rating 3 Rating 5
Coffee @ 65C Rating 3 Rating 4-5
Synthetic soil AATCC composition Rating 3 Rating 5

* Test is outside our scope of accreditation. A = Vi-Chem tests annually.


** This test was performed by a subcontracted accredited testing laboratory. All other tests are performed once at the time of the original lab report date.
*** This test was performed at suppliers biological laboratory. This report is not to be reproduced except in full.
O:\2014\431_Sevrene3000-60A_WSS-M2D510-A6.doc
Additional information about testing may be found in the accreditation section on our website at www.vichem.com
VI-Chem Corporation, 55 Cottage Grove, SW, Grand Rapids, MI 49507 Office (616) 247-8501 or (800) 477-8501, Fax (616) 247-8703
ANNUAL LABORATORY TEST REPORT
COMPOUND: Sevrene 3000-60A ANNUAL REPORT DATE: 02/05/14
COLOR: N/A ORIGINAL LABORATORY REPORT DATE: 7/13/09
SPECIFICATION: WSS-M2D510-A6 PAGE: Page 2 of 3

DATA REPRESENTS ACTUAL LABORATORY TESTS AND REMAINS CURRENT FOR ONE YEAR

Test
Freq. Test Method Spec. Range Results

Cleaning Agent Resistance


(FLTM BN 107-01, 10 Cycles,
AATCC Evaluation Procedure 2)* **, max.

Dry cheesecloth Rating 4 Rating 4-5


Deionized water Rating 4 Rating 4-5
Window cleaner containing Ammonia Rating 4 Rating 4-5
All Purpose Cleaner Rating 4 Rating 4
Isopropyl alcohol/water, 50:50 by volume Rating 4 Rating 4-5

A Density (ISO 1183, Method A) 1.14 .03 1.11

A Hardness, Shore A, 15 sec. delay 61 - 70 66


(ISO 868/ASTM D2240)

A Tensile Strength, MPa (ISO 527, Type 2 4.6 MPa min.. 9.0 MPa
Specimen at 500 mm/min.

A Tensile Modulus @ 100% Elongation 2.0 MPa min. 2.3 MPa


(MPa)

A % Elongation at break, min. --- 769%


ISO 527, Type 5A, Specimens 500 mm/min.

A Tear Strength, kN/m width (ISO 34, Method B, 22 kN/m min. 29.2 kN/m
Procedure A)

Change in Properties (Tensile, Elongation,


Hardness) from Original, after Heat Aging
(ISO 188, except 150 air changes/h.
1000 h 100 2C)
% Retention of Tensile Strength 25% of original value + 16.4%
% Retention of Elongation at Break 25% of original value + 8.2%
Change in hardness 10 points of original value + 5.4
Appearance No objectionable color change Pass
or change in tackiness

* Test is outside our scope of accreditation. A = Vi-Chem tests annually.


** This test was performed by a subcontracted accredited testing laboratory. All other tests are performed once at the time of the original lab report date.
*** This test was performed at suppliers biological laboratory. This report is not to be reproduced except in full.
O:\2014\431_Sevrene3000-60A_WSS-M2D510-A6.doc
Additional information about testing may be found in the accreditation section on our website at www.vichem.com
VI-Chem Corporation, 55 Cottage Grove, SW, Grand Rapids, MI 49507 Office (616) 247-8501 or (800) 477-8501, Fax (616) 247-8703
ANNUAL LABORATORY TEST REPORT
COMPOUND: Sevrene 3000-60A ANNUAL REPORT DATE: 02/05/14
COLOR: N/A ORIGINAL LABORATORY REPORT DATE: 7/13/09
SPECIFICATION: WSS-M2D510-A6 PAGE: Page 3 of 3

DATA REPRESENTS ACTUAL LABORATORY TESTS AND REMAINS CURRENT FOR ONE YEAR

Test
Freq. Test Method Spec. Range Results

Coefficient of Linear Thermal Expansion, --- 8.8 x 10-5


-30C to 100C, ASTM D696

* Test is outside our scope of accreditation. A = Vi-Chem tests annually.


** This test was performed by a subcontracted accredited testing laboratory. All other tests are performed once at the time of the original lab report date.
*** This test was performed at suppliers biological laboratory. This report is not to be reproduced except in full.
O:\2014\431_Sevrene3000-60A_WSS-M2D510-A6.doc
Additional information about testing may be found in the accreditation section on our website at www.vichem.com
VI-Chem Corporation, 55 Cottage Grove, SW, Grand Rapids, MI 49507 Office (616) 247-8501 or (800) 477-8501, Fax (616) 247-8703