You are on page 1of 4

10

10 Ten Reasons
to Specify Trench COTA Bushings
Transformer Bushings
Type COTA

1 Paper/Foil
Oil Condenser
today, including vandalism,
earthquakes and heavy pollution. In
addition, Trench COTA bushings with
ratings to 3,000 amps. Now almost
all medium power transformers
through 100 MVA can have all draw
The extremely high dielectric a composite insulator can weigh lead bushings. The Split-Conductor
resistance obtained with the proven nearly 50% less than other brands draw lead feature allows shorter
Trench paper/foil oil condenser of bushings, making them ideal for installation times and ensures
provides superior impulse protection mobile substations. factory tested transformer lead
and high resistance to steep connections.
transients. The Trench design ensures
that COTA bushings will last the life
of your power transformer.
4 Shatter Resistant
In-board Ends 7 One-Piece Porcelain
(Glued Porcelain)
Every Trench COTA bushing is

2 Porcelain Cemented
to Flange
offered with a shatter resistant in-
board end insulator. These insulators
All Trench COTA bushings, through
161 kV offer, as standard, one-piece
porcelain. On request 230 kV COTA
(46 kV and above) are less susceptible to damage from
handling. They will not shatter bushings can be provided with one-
This unique process ensures high like porcelain preventing major piece porcelain.
cantilever strength and eliminates transformer repair costs. Trench in-
the possibility of oil leaks where the board end insulators have 25 years For 230 kV bushings and above
porcelain meets the flange. of proven field experience. multiple pieces of porcelain are used
and to ensure the best possible

5 Embedded End Shield


(46 kV and above)
joint between the porcelain pieces a
special gluing process is used. This
gluing process eliminates the use of
High voltage bushings require an gaskets, which can deteriorate and
end shield to control the electrical cause the bushing to fail.
field strength at the in-board end of
the bushing. Instead of mounting
this shield externally, Trench embeds
the shield in the epoxy-resin in-
board end insulator. This provides
a more uniform distribution of
the electrical forces and reduces
the required clearances. The
embedded end shield provides
greater interchangeability with other
bushings, making Trench COTA
bushings the ideal replacement
bushing.

3 Optional
Composite Insulator
For more than 15 years, Trench
6 Split-Conductor
(Super Draw Lead)
has offered transformer bushings Historically bushings through 69
with outdoor composite insulators. kV only offered a draw lead rating
Composite insulators are proven of 400 amps. Today, using the
to provide solutions to many of Trench Split-Conductor in COTA
the problems faced by the industry bushings you now have draw lead

2
1

2
3

9 Multi-Contacts 10 Quality
6 As we have seen in item 6 Trench Everyone talks about quality; nearly
COTA bushings provide extremely everyone is ISO 9001 certified
7
high draw lead capabilities. This is including Trench but that is not the
accomplished by eliminating the whole picture. Quality starts at the
8 threaded joint inside the top termi- beginning, it starts with the design.
nal and replacing the threads with When you compare a Trench COTA
Multi-contacts. The multi-contacts bushing with other brands you will
9 are made from high-grade beryllium find quality design features not of-
10 copper alloy, silver-plated and fered by the others. These include
installed inside the bolted top O-ring gaskets
terminal. instead of flat gaskets, compression
11 springs not in the bushings oil, the
interior of all castings painted, easy
to read prismatic oil level
1 Top terminal
indicators and stainless steel test tap
2 Multi-Contact caps just to mention a few.
3 Retaining pin with locking device
Quality is the reason Trench offers
4 Central tube
the only standard three-year bushing
5 Split Conductor upper part warranty in the business.
6 Mounting flange 85 years in the bushing business
and still growing, Trench, the quality
7 Gasket surface flange
choice for bushings.
8 Split Conductor lower part
9 Epoxy insulator
10 End-shielding
11 Bottom terminal

Split-Conductor
COTA150... COTA900
Top terminal
Draw lead stud

8 Bolted Top Terminal


Multi-Contact
Retaining pin with locking device
4 Fixing screws
Unlike other bushing designs, where
End of draw
lead cable

the top terminal is threaded onto the


bushing the Trench COTA bushing O-Ring gasket
utilizes a top terminal that is bolted
Distance to gasket of
flange see outline drawing

Bushing head
to the head of the bushing. This fea-
ture eliminates the requirement to
check the top terminal for tightness, Terminal ID
increasing reliability and provides a
truly maintenance free bushing. Top Terminal
COTA Draw
Lead Bushings

3 3
Trench Facilities

Trench Austria GmbH Trench Limited


Paschinger Strasse 49 Instrument Transformer Division
Postfach 13 390 Midwest Road
A-4060 Linz-Leonding Scarborough, Ontario
Austria Canada M1P 3B5
Phone: 43-732-6793-0 Phone: 416-751-8570
Fax: 43-732-671341 Fax: 416-751-6952

Trench Brasil Ltda Trench Limited


Via Expressa de Contagem, 2685 Power Line Carrier Division
Contagem, Minas Gerais 815 Middlefield Road, Unit 6A
CEP 32370-485 Scarborough, Ontario
Brazil Canada M1V 2P9
Phone: 55-31-3391-5959 Phone: 416-291-8544
Fax: 55-31-3391-1828 Fax: 416-291-5581

Trench China Trench France S.A.


MWB (Shanghai) Co., Ltd. 16, Rue du Gnral Cassagnou
No. 3658, Jiancheng Road B.P. 70 F-68 302
Minhang, Shanghai St. Louis, Cedex
Peoples Republic of China France
200245 Phone: 33-3 89-70-2323
The Trench Group is your Phone: 86-21-54720088 Fax: 33-3 89-67-2663
Fax: 86-21-54723118
Trench Germany GmbH
partner of choice for electrical Trench High Voltage Nrnberger Strasse 199
Products Ltd., Shenyang D-96050 Bamberg
No. 2 Zhengliang Er. Road Germany
power transmission and Jing Shen Xi San Street Phone: 49-951-1803-0
Dao Yi Economic Development Zone Fax: 49-951-1803-224
Shenyang 110136 P.R. China
distribution solutions today; Phone: 86-24-89722688 Trench Switzerland AG
Fax: 86-24-89737200 Lehenmattstrasse 353
and for the development of CH-4028
Trench Limited Basel
Bushing Division Switzerland
your new technology solutions 432 Monarch Avenue Phone: 41-61-315-51-11
Ajax, Ontario Fax: 41-61-315-59-00
Canada L1S 2G7
of tomorrow. Phone: 905-426-2665 Trench (UK) Limited
Fax: 905-426-2671 South Drive
Hebburn
Trench Limited Tyne & Wear
Coil Product Division NE 31 1 UW
71 Maybrook Drive Phone: 44-191-483-4711
Scarborough, Ontario Fax: 44-191-430-0633
Canada M1V 4B6
Phone: 416-298-8108
Fax: 416-298-2209

www.trenchgroup.com
E 322.61
Subject to change without notice (05.2006)
Printed in Canada.

You might also like