ASPECTS TO BE CONSIDERED FOR CIRCULATION PLANNING:
Circulation area can be broken into two types, Primary circulation Secondary circulation. Primary circulation is the main route connecting the building core and common spaces such as elevator lobbies, exit stairs and a core toilet. Secondary circulation is the aisles between the individual and support spaces. As a general planning thumb rule, Circulation areas comprises roughly 12% to 16% of total usable areas. The width and height of the circulation space should be proportionate with the type and the amount of movement it must handle. The distinction in scale should be establish between a public promenade , a more private hall and a service corridor. A narrow enclosed path naturally encourages forward motion. To accommodate more traffic as well as to create space for pausing, resting, or viewing sections of path can be widened. The path can also be enlarged by merging with spaces it pass through. Within a large space, a path can be random, without form or definition, and be determined by the activities and arrangement of furnishing within a space. 2.COMPARATIVE ANALYSIS:
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY
1.SITE 1. TWO ZONES
ALL IN ONE. SELF SUFFICIENT SERIES OF FULLY BLOCK CLOSELY PEDESTRAINED INTERLOCK 2. OLD AND NEW WITH EACH OTHER.
CAMPUS.
1.ENTRANCE 1. SUSPENCE ALL THREE HAS
SUSPENCE GOOD APPROACH. HIERARCHY DOMINANCE 2. FRONTAL FRONTAL APPROACH APPROACH.
BOLD OPENINGS. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
3.PARKING 1.FULLY PARKING IS IIM AHMEDABAD
PEDSTRAINED. PROVIDED WITHIN HAS ALL KIND OF 2.HAS VEHICULAR, A CAMPUS VEHICULAR CYCLING AND OUTSIDE THE MOVEMENT AND PEDESTRAINED BUILDING BLOCK. IT HAS PARKING NETWORK AND INSIDE THE BLOCK ZONES NEAR ALL PARKINGS ARE IS FULLY BLOCKS. PROVIDED AT PEDESTRAINED. VARRIOUS SPOTS.
4.PROXIMITY 1.EACH BLOCK IS ALL BLOCKS ARE IIM AHMEDABAD
CONNECTED WITH CLOSELY HAS GOOD ACADEMIC BLOCK. INTERLOCKED PROXIMITY HENCE 2.EACH BLOCKS WITH EACH OTHER ALL BLOCKS WERE ARE PLACED IN A LINEAR ZONED ACCORDIND TO PATTERN. ACCORDING TO THE USAGE. THE USAGE. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
5.CORRIDORS 1.HIERARCHY IN CORRIDORS ACTS ALL THREE
CIRCULATION IS AS A MAIN COLLEGES USED ACHEIVED BY CONNECTING THIER CORRIDORS CORRIDORS. ELEMENT. IN DIFFERENT 2.HIERARCHY IN VARIOUS APPROACH AND CIRCULATION IS ELEMENTS ARE THAT HAS A GOOD ACHEIVED BY FRAMED AT ROLE IN DESIGN. BOLD OPENINGS CORRIDORS. AND SPACES AROUND IT.
6.STAIRCASE 1.NO STAIRCASES STAIRCASES ARE IIM HAS USED
BUT STEPS ARE USED FOR STAIRCASE AS USED AT LEVELS. MESSANINE. MULTI 2.BROAD FUNCTIONALLY. STAIRCASES ARE CARE STAIRCASES USED WHICH ALSO ARE ACTS AS AESTHETICALLY AMPHITHEATRE. TREATED. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
7.STREET SCAPE 1.ALL THE INTERNAL BOTH AT IIM AND
CORRIDOR HAS CORRIDORS HAVE CARE ALMOST ALL BUILDING ON ONE BUILDING ON ONE STREETS WERE SIDE AND SIDE AND FRAMED WITH LANDSCAPE ON COURTYARD ON BOLD OTHER. OTHER. OPENINGS.IT CAN 2.ONE SIDE EXTERNAL BE VISIBLE AT ALL BUILDING AND CORRIDORS HAVE LEVELS. OTHER WITH LANDSCAPE ON MASSIVE OPENING TWO SIDES.
8.OPEN AND 1.EVERY SPACE EACH BLOCKS IN CARE AND
ARE DESIGNED HAS ITS OWN MAHENDRA OPEN CLOSED SPACE WITH OPEN COURTYARD AND SPACES ACTS AS A RELATION SHIP. SPACES. EVERY CLASS INFORMAL 2.EVERY BLOCKS ROOM IS GATHERING AND HAS ITS OWN CONNECTED TO LEARNING.IN IIM LANDSCAPE AS THE COURTYARD. BROAD GATHERING SPACE. CORRIDORS ACTS AS A GATHERING SPACE. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
9.CLASS ROOMS 1.EACH CLASS SEMI-CLOSED ALL THE THREE
ROOM HAS ITS CLASSROOMS HAS COURYARD AT OWN COURTYARD WITH COURTYARD EVERY CLASS AT LOWER LEVEL. AS INFORMAL ROOMS FOR 2.SEMINAR CLASS LEARNING SPACE. INFORMAL ROOM LEARNING. CARE ARRANGEMENT HAS SEMI CLOSED WITH ITS OWN CLASS ROOMS COURT IN IT. WHICH AFFECTS PRIVACY.
11.VISUAL 1.TRADITIONAL VARIOUS ALL THE THREE
INDIAN ELEMENTS ARE COLLEGES HARMONY DESIGN.USED FRAMED . CREATED VISUAL RAMPS, STONE CONTUINITY THAT HARMONY WITH BOX SEATS AND CREATES HARMONY. THIER DESIGN STEPS. CONCEPTS AND 2.ARCHES, BOLD ELEMENTS. OPENINGS, BROAD CORRIDORS. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
12.PATTERNS 1.RADIAL LINEAR PATTERN IIM PATTERN IS
PATTERN.ACADEMI SERIES OF BLOCKS GOOD BECAUSE C BLOCK ACTS AS A CONNCTED WITH EVERY BLOCK IS CORE. ONE ANNOTHER. SURROUNDED BY 2.HETROGENEOUS MORE OPEN SPACE PATTERN. SO THAT IN CASE OF CHANGE OR GROWTH IT CAN BE EASILY ACCOMODATE.
13.FLEXIBILITY 1.FLEXIBILTY IS FLEXIBILITY IS IIM IS MOE
MAINTAINED BUT MAINTAINED FLEXIBLE THAN IS AFFEECTED BY FAIRLY. THE TWO BECAUSE FORMS. IN CASE OF 2.GOOD FURTHER GROWTH FLEXIBILITY. MAHENDRA WILL GET AFFECTED BY FORM AND CARE BY SPACE. PARAMETERS LITERATURE LIVE STUDY INFERRENCE STUDY
14.SAFETY 1.SECURED FRONT SAFETY IS CARE COLLEGE
ENTRANCE. MAINTAINED AT ACHEIVED SAFETY 2.SAFETY IS ALL LEVELS. BY MEANS OF MAINTAINED WALKWAYS ARE DESIGN THROUGH OUT FRAMED. ITSELF.MAHENDRA THE CAMPUS WITH ALL CORRIDORS BY SECURED VARIOUS AND SPACES ARE ENTRANCE AND SECURITY BLOCKS. VISIBLE AND IIM BY SECURITY SECURED. BLOCKS.
15.MATERIAL 1.PAVED EXTERNAL THAR CARE COLLEGE
PATHWAYS ROAD AND SONED USED DIFFERENT SHAHABAD PATHWAY. KIND OF STONE. INERNAL GRANITE MATERIALS IN 2.EXTERNAL THAR FLOORING. PATHWAYS AS ROADS AND WELL AS IN INTERNAL LANDSCAPES. GRANITE FLOORING. 3.SPATIAL STANDARDS Lobby length: Where swing doors are used, a minimum clear length of: 1570 mm should be provided for general traffic access, 4100 mm should be provided for bed/trolley access. Lobby width: For lobbies with single doors for general traffic, a minimum clear width of 1500 mm is recommended. For lobbies with double doors (sliding or swing) for patient trolley/bed access, a minimum clear width of 2150 mm is required. Internal stairs: Rise and goings should be uniform through out the flight . Riser 150 170 mm. Thread 280 300 mm. Landing area: A landing area should be provided at the top and bottom of the stairs (1200 mm). Nosing: Depth 50 to 60 mm. Ramps: Ramps may be provided in place of steps in some situations, in particular to facilitate egress of wheelchair users or those with push chairs. Area under the staircase: If enclosure is not possible, two rails one at 1000 mm and one at 200 mm above floor level or some other barrier should be provided. Lifts: Minimum internal dimension 1100 mm x 1400 mm accommodating at least 8 people (630 kg). Entrance 8 m to 12 m to receive an increasing crowd. Corridors 2.5 m 4 m. ( 3m will be optimum). Railing height 0.9 m. Emergency exits 5 m 7 m. Lighting: The lighting should be designed so that it highlights the difference between riser and threads, top and bottom of the steps and any changes in direction. Lighting that causes glare ( for example poorly located spot lights, foot lights or low level light source ) should be avoided. Natural lighting is preferred and is supported through the facades. THANK YOU