You are on page 1of 12

1.

ASPECTS TO BE CONSIDERED FOR CIRCULATION PLANNING:


Circulation area can be broken into two types,
Primary circulation
Secondary circulation.
Primary circulation is the main route connecting the building core and common spaces such
as elevator lobbies, exit stairs and a core toilet.
Secondary circulation is the aisles between the individual and support spaces.
As a general planning thumb rule, Circulation areas comprises roughly 12% to 16% of total
usable areas.
The width and height of the circulation space should be proportionate with the type and the
amount of movement it must handle.
The distinction in scale should be establish between a public promenade , a more private
hall and a service corridor.
A narrow enclosed path naturally encourages forward motion.
To accommodate more traffic as well as to create space for pausing, resting, or viewing
sections of path can be widened.
The path can also be enlarged by merging with spaces it pass through.
Within a large space, a path can be random, without form or definition, and be determined
by the activities and arrangement of furnishing within a space.
2.COMPARATIVE ANALYSIS:

PARAMETERS LITERATURE LIVE STUDY INFERRENCE


STUDY

1.SITE 1. TWO ZONES


ALL IN ONE.
SELF SUFFICIENT SERIES OF
FULLY BLOCK
CLOSELY
PEDESTRAINED INTERLOCK
2. OLD AND NEW WITH EACH OTHER.

CAMPUS.

1.ENTRANCE 1. SUSPENCE ALL THREE HAS


SUSPENCE GOOD APPROACH.
HIERARCHY
DOMINANCE
2. FRONTAL FRONTAL
APPROACH APPROACH.

BOLD OPENINGS.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

3.PARKING 1.FULLY PARKING IS IIM AHMEDABAD


PEDSTRAINED. PROVIDED WITHIN HAS ALL KIND OF
2.HAS VEHICULAR, A CAMPUS VEHICULAR
CYCLING AND OUTSIDE THE MOVEMENT AND
PEDESTRAINED BUILDING BLOCK. IT HAS PARKING
NETWORK AND INSIDE THE BLOCK ZONES NEAR ALL
PARKINGS ARE IS FULLY BLOCKS.
PROVIDED AT PEDESTRAINED.
VARRIOUS SPOTS.

4.PROXIMITY 1.EACH BLOCK IS ALL BLOCKS ARE IIM AHMEDABAD


CONNECTED WITH CLOSELY HAS GOOD
ACADEMIC BLOCK. INTERLOCKED PROXIMITY HENCE
2.EACH BLOCKS WITH EACH OTHER ALL BLOCKS WERE
ARE PLACED IN A LINEAR ZONED
ACCORDIND TO PATTERN. ACCORDING TO
THE USAGE. THE USAGE.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

5.CORRIDORS 1.HIERARCHY IN CORRIDORS ACTS ALL THREE


CIRCULATION IS AS A MAIN COLLEGES USED
ACHEIVED BY CONNECTING THIER CORRIDORS
CORRIDORS. ELEMENT. IN DIFFERENT
2.HIERARCHY IN VARIOUS APPROACH AND
CIRCULATION IS ELEMENTS ARE THAT HAS A GOOD
ACHEIVED BY FRAMED AT ROLE IN DESIGN.
BOLD OPENINGS CORRIDORS.
AND SPACES
AROUND IT.

6.STAIRCASE 1.NO STAIRCASES STAIRCASES ARE IIM HAS USED


BUT STEPS ARE USED FOR STAIRCASE AS
USED AT LEVELS. MESSANINE. MULTI
2.BROAD FUNCTIONALLY.
STAIRCASES ARE CARE STAIRCASES
USED WHICH ALSO ARE
ACTS AS AESTHETICALLY
AMPHITHEATRE. TREATED.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

7.STREET SCAPE 1.ALL THE INTERNAL BOTH AT IIM AND


CORRIDOR HAS CORRIDORS HAVE CARE ALMOST ALL
BUILDING ON ONE BUILDING ON ONE STREETS WERE
SIDE AND SIDE AND FRAMED WITH
LANDSCAPE ON COURTYARD ON BOLD
OTHER. OTHER. OPENINGS.IT CAN
2.ONE SIDE EXTERNAL BE VISIBLE AT ALL
BUILDING AND CORRIDORS HAVE LEVELS.
OTHER WITH LANDSCAPE ON
MASSIVE OPENING TWO SIDES.

8.OPEN AND 1.EVERY SPACE EACH BLOCKS IN CARE AND


ARE DESIGNED HAS ITS OWN MAHENDRA OPEN
CLOSED SPACE WITH OPEN COURTYARD AND SPACES ACTS AS A
RELATION SHIP. SPACES. EVERY CLASS INFORMAL
2.EVERY BLOCKS ROOM IS GATHERING AND
HAS ITS OWN CONNECTED TO LEARNING.IN IIM
LANDSCAPE AS THE COURTYARD. BROAD
GATHERING SPACE. CORRIDORS ACTS
AS A GATHERING
SPACE.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

9.CLASS ROOMS 1.EACH CLASS SEMI-CLOSED ALL THE THREE


ROOM HAS ITS CLASSROOMS HAS COURYARD AT
OWN COURTYARD WITH COURTYARD EVERY CLASS
AT LOWER LEVEL. AS INFORMAL ROOMS FOR
2.SEMINAR CLASS LEARNING SPACE. INFORMAL
ROOM LEARNING. CARE
ARRANGEMENT HAS SEMI CLOSED
WITH ITS OWN CLASS ROOMS
COURT IN IT. WHICH AFFECTS
PRIVACY.

11.VISUAL 1.TRADITIONAL VARIOUS ALL THE THREE


INDIAN ELEMENTS ARE COLLEGES
HARMONY DESIGN.USED FRAMED . CREATED VISUAL
RAMPS, STONE CONTUINITY THAT HARMONY WITH
BOX SEATS AND CREATES HARMONY. THIER DESIGN
STEPS. CONCEPTS AND
2.ARCHES, BOLD ELEMENTS.
OPENINGS, BROAD
CORRIDORS.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

12.PATTERNS 1.RADIAL LINEAR PATTERN IIM PATTERN IS


PATTERN.ACADEMI SERIES OF BLOCKS GOOD BECAUSE
C BLOCK ACTS AS A CONNCTED WITH EVERY BLOCK IS
CORE. ONE ANNOTHER. SURROUNDED BY
2.HETROGENEOUS MORE OPEN SPACE
PATTERN. SO THAT IN CASE
OF CHANGE OR
GROWTH IT CAN
BE EASILY
ACCOMODATE.

13.FLEXIBILITY 1.FLEXIBILTY IS FLEXIBILITY IS IIM IS MOE


MAINTAINED BUT MAINTAINED FLEXIBLE THAN
IS AFFEECTED BY FAIRLY. THE TWO BECAUSE
FORMS. IN CASE OF
2.GOOD FURTHER GROWTH
FLEXIBILITY. MAHENDRA WILL
GET AFFECTED BY
FORM AND CARE
BY SPACE.
PARAMETERS LITERATURE LIVE STUDY INFERRENCE
STUDY

14.SAFETY 1.SECURED FRONT SAFETY IS CARE COLLEGE


ENTRANCE. MAINTAINED AT ACHEIVED SAFETY
2.SAFETY IS ALL LEVELS. BY MEANS OF
MAINTAINED WALKWAYS ARE DESIGN
THROUGH OUT FRAMED. ITSELF.MAHENDRA
THE CAMPUS WITH ALL CORRIDORS BY SECURED
VARIOUS AND SPACES ARE ENTRANCE AND
SECURITY BLOCKS. VISIBLE AND IIM BY SECURITY
SECURED. BLOCKS.

15.MATERIAL 1.PAVED EXTERNAL THAR CARE COLLEGE


PATHWAYS ROAD AND SONED USED DIFFERENT
SHAHABAD PATHWAY. KIND OF
STONE. INERNAL GRANITE MATERIALS IN
2.EXTERNAL THAR FLOORING. PATHWAYS AS
ROADS AND WELL AS IN
INTERNAL LANDSCAPES.
GRANITE
FLOORING.
3.SPATIAL STANDARDS
Lobby length:
Where swing doors are used, a minimum clear length of:
1570 mm should be provided for general traffic access,
4100 mm should be provided for bed/trolley access.
Lobby width:
For lobbies with single doors for general traffic, a minimum clear width of 1500 mm is
recommended.
For lobbies with double doors (sliding or swing) for patient trolley/bed access, a minimum
clear width of 2150 mm is required.
Internal stairs:
Rise and goings should be uniform through out the flight . Riser 150 170 mm. Thread
280 300 mm.
Landing area:
A landing area should be provided at the top and bottom of the stairs (1200 mm).
Nosing:
Depth 50 to 60 mm.
Ramps:
Ramps may be provided in place of steps in some situations, in particular to facilitate egress
of wheelchair users or those with push chairs.
Area under the staircase:
If enclosure is not possible, two rails one at 1000 mm and one at 200 mm above floor level
or some other barrier should be provided.
Lifts:
Minimum internal dimension 1100 mm x 1400 mm accommodating at least 8 people (630
kg).
Entrance 8 m to 12 m to receive an increasing crowd.
Corridors 2.5 m 4 m. ( 3m will be optimum).
Railing height 0.9 m.
Emergency exits 5 m 7 m.
Lighting:
The lighting should be designed so that it highlights the difference between riser and threads,
top and bottom of the steps and any changes in direction.
Lighting that causes glare ( for example poorly located spot lights, foot lights or low level light
source ) should be avoided. Natural lighting is preferred and is supported through the facades.
THANK YOU

You might also like