You are on page 1of 3

Industrial Sensors / Ultrasonic Sensors

UT2 Series/ Ultrasonic Sensors


Switching / Measuring Sensors

Construction type: M30x1.5


Connector: M12 plug, 4-pin / Cable 
Housing material: Plastic (PBT)
IP67 Ingress Protection
Power supply: 15 - 30 V DC

UT2F/xx-0xUL
general data
Measuring method Ultrasonic
Sensorfunction Measure, switch
Construction type M30x1.5
Connecotor M12 plug, 4-pin / Cable
Current output analog Yes
Analogausgang Spannung No
Display elements LED Multifunction
Temperature compensation Yes
Teach-in External
Measuring data
Measuring range 350 - 6000 mm
Blind zone 350 mm
Beam angle 15 2
Repeat accuracy 0.5 %
Linearity error 1%
Response time 500 ms
Temperature drift 5%
Outputs
Number of Outputs 2
Output type NO / NC (switchable)
Load resistance 3 k
Switching hysteresis 1%
Switching frequency 1 Hz
Sensitivity adjustment Teach-in button
Power supply
Power supply V DC 12 - 30 V DC / 15 - 30 V DC (analog 0 -10 V)
No-load current 50 mA
Short circuit protection Yes
Reverse polarity protection Yes
Ripple 5%
Voltage drop 2.2 V @ 100 mA
Leakage current 10 A @ 30 V DC

1
Zum Hagenbach 7 D-48366 Laer Fon: +49 (0)2554/9130-00 Fax: +49 (0)2554/9130-10 info@welotec.com
www.welotec.com
Industrial Sensors / Ultrasonic Sensors

UT2 Series / Ultrasonic Sensors


Technical details
UT2F/xx-0xUL
Physical characteristics
Housing material Plastic (PBT)
Optic material Epoxy glass-resin
Ingress protection IP67
Dimensions ( x L) 30 x 100 mm (Plug) / 30 x 93 mm (Cable)
Cable length 2000 mm (Cable)
Weight 130 g (Plug) / 199 g (Cable)
Environmental
Opterating temperature
-20 - +70 C
range
Storage temperature range -35 - +70 C
Approvals
CE EC Directive 2004/108/EC
EMC EN 60947-5-2,7
cULus Yes

Versions

Construc- Measuring Connec- PNP NO/NC NPN NO/NC PNP NO/NC NPN NO/NC
2 x PNP 2 x NPN
tion type range tion Type 0 - 10 V 0 - 10 V 4 - 20 mA 4 - 20 mA
UT2 Series
M12 Con- UT2F/E7- UT2F/E9- UT2F/E6- UT2F/E4- UT2F/EW- UT2F/EM-
350 - 6000 nector 0EUL 0EUL 0EUL 0EUL 0EUL 0EUL
M30x1.5
mm UT2F/E7- UT2F/E9- UT2F/E6- UT2F/E4- UT2F/EW- UT2F/EM-
Cable
0AUL 0AUL 0AUL 0AUL 0AUL 0AUL

UT2F/**-**
Sensing area Connector
UT2F/** -**
600,0

500,0
UT*/E4-0EUL
Digital out Supply (-)
400,0
UT*/E6-0EUL
300,0
4 3
parallel displacement (mm)

UT*/E7-0EUL
200,0
UT*/E9-0EUL
1 2
100,0

0,0

-100,0 Supply (+) Analogue out


-200,0

-300,0

-400,0

-500,0

-600,0

Distanzadistance (mm)[mm]
/ Distance

2
Zum Hagenbach 7 D-48366 Laer Fon: +49 (0)2554/9130-00 Fax: +49 (0)2554/9130-10 info@welotec.com
www.welotec.com
Industrial Sensors / Ultrasonic Sensors

UT2 Series / Ultrasonic Sensors


Dimensions

UT2F/xx-EUL
UT2F/xx-EUL
UT2F/xx-EUL (Plug)
(Plug)

multifunction
multifunction flexible
Teach-in flexible
Teach-in button
button washer
washer
2 1
1 8,5
8,5 3
3 4
4 3
3
SSW2
W3

Welotec is using a ISO 9001:2008 certified quality management system All specifications are subject to change
Plastic
366 Plastic
tightening nut
tightening nut
6.4
6.4

M30x1.5
M30x1.5
38.8
4455

38.8

M12x1
M12x1
6.2
6.2


55 19.5 59 10.4
19.5 59 10.4
100
SW
SW 35
35
100
40
40
UT2F/xx-AUL
UT2F/xx-AUL (Cable)
(Cable)
UT2F/xx-AUL
multifunction
multifunction flexible
flexible
Teach-in
Teach-in button
button washer
washer
2
2 1
1
8.5
8.5 3
3 4
4 3
3
SSW
W3
366 Plastic
Plastic
tightening
tightening nut
nut
6.4
6.4

4.7
4.7
M30x1.5
M30x1.5
38.8
38.8
6.1
6.1

1
1 19.5
19.5 59
59 10.5
10.5 SW
SW 35
35
93
93
40
40

Electrical diagrams

NP
NO/NC
NP NO/NC
NO/NC ++analogue
NO/NC +analogue
+analogue
analogue
output
output
output
output NPN
NPN
NO/NC
NO/NC
models
models
+ analogue
+ analogue
output
output
PNP NO/NC and analog NPN NO/NC and analog

1 Bn
1 Bn + + 1 Bn
1 Bn + +

4 Bk
4 Bk 2 Wh
2 Wh
Digital
Digital
output
output
CAT-UT2-V1-EN ed. 10/14 Welotec GmbH

Analogue
Analogue
output
output

2 Wh
2 Wh 4 Bk
4 Bk
Digital
Digital
output
output Analogue
Analogue
output
output

3 Bu
3 Bu 3 Bu
3 Bu
- - - -

3
Zum Hagenbach 7 D-48366 Laer Fon: +49 (0)2554/9130-00 Fax: +49 (0)2554/9130-10 info@welotec.com
www.welotec.com

You might also like