You are on page 1of 1

PORTABLE FLUE GAS / COMBUSTION ANALYZER

MODEL: ICA
FEATURES:
Measures: Draft, O2, CO-H2 compensated, Flue
gas and ambient Temperatures
Calculates: CO2, CO-undiluted, Efficiency,
Excess air (Lambda) and Losses
Optionally measures NO & SO2 and
calculates NOx
The sensors are safe for storage to -22F (-30C)
Ideal for monitoring and servicing industrial
combustion systems
2 separate pumps for gas and flush operations
Data logger can store 10 blocks of data
Selective filter protection for sensors ensures
maximum service life GENERAL SPECIFICATIONS
Integral printer and RS-232 serial interface
Storage Temperature: -22 to 140F (-30 to 60C)
Displays eight readings simultaneously Power Supply: 6V Ni Cad battery with charger
Battery Life: 20 hours
Automatic self test and calibration Dimensions: 9.5 X 4.0 X 8.25
Weight: 7.2 lbs.
SPECIFICATIONS Unit comes complete with:
Factory calibrated and installed oxygen,
Flue Gas Temperature: carbon monoxide and draft sensors
Sensor: K-type Thermocouple Rechargeable battery and charger
Range: 32 to 1,850F (0 to 1,000C) Built in printer
Resolution: 1F or C
1 pc. flue gas temp. probe / watertrap with 8 hose assembly
Accuracy: 2F / 1C (0 to 400C)
0.5% of reading (up to 1,000C) 1 pc. ambient temperature sensor
Ambient Room Temperature: 1 pc. carrying case & instruction manual
Sensor: K-type Thermocouple Optional:
Range: -5 to 212F (-20 to 100C) OPTIONAL SENSORS
Resolution: 0.1F or C Nitrogen monoxide (NO) Measurement: PN 7130
Sensor: Electro-chemical cell
Accuracy: 2F / 1C (0.1 to 100C) Range: 0 to 2,000 ppm
6F / 3C (-20 to 0.0C) Resolution: 1 ppm
Oxygen (O2) measurement: Accuracy: 5 ppm(50 to100 ppm)
Sensor: Electro-chemical cell 5% of reading (up to 2000 ppm)
Range: 0.0 to 20.9% High Concentration Carbon monoxide (CO) Measurement: PN 7131
Sensor: Electro-chemical cell
Resolution: 0.1%
Range: 0 to 10,000 ppm
Accuracy: 0.2% Resolution: 100 ppm or 0.01% Vol
Carbon monoxide (CO) Measurement (with H2 Compensation): Sulfur dioxide (SO2) Measurement: PN 7132
Sensor: Electro-chemical cell Sensor: Electro-chemical cell
Range: 0 to 2,000 ppm Range: 0 to 2,000 ppm
Resolution: 1 ppm Resolution: 1 ppm
Accuracy: 5 ppm (<150 ppm) Accuracy: 5 ppm (<100 ppm)
5% of reading (up to 2000 ppm)
5% of reading (up to 2,000 ppm) Draft Measurement (High Range):
Draft Measurement: Sensor: Piezoresistive semiconductor sensor
Sensor: Semiconductor sensor Range: 40.00 inches H20 or 99.99 mbar
Range: 8.00 inches H2O or 19.99 mbar Resolution: 0.01 in. H20 or mbar
Resolution: 0.01 in. H2O or mbar Accuracy: 0.02 in. H20/0.05 mbar(up to 8.0 in. H20)
Accuracy: 0.01 in. H2O / 0.02 mbar (< o.8 in. H2O) 1% of reading (8.0 to 40.0 in. H20
1% of reading (0.8 to 8.0 in. H2O) Nitrogen dioxide (NO2) Calculation:
Carbon dioxide (CO2) Calculation: Calculated from NO measurement
Calculated from O2 measurement Range: 0 to 2,000 ppm
Range: 0.0 to CO2max %* Resolution: 1 ppm
Resolution: 0.1% Accuracy: 5 ppm (<100 ppm)
Accuracy: 0.2% Soot pump PN 7112
*CO2max % - Maximum CO2 value(relative to fuel) in % Immersion Temperature probe PN TK102
Display: Four line LCD - eight readings (backlit) Surface Temperature probe PN TK103
Datalink: RS-232 serial port Air Temperature probe PN TK104
Integral Printer: Seico with plain 60 mm paper Pipe Clamp-onTemperature probe PN TK107
Operating Temperature: 50 to 104F (10 to 40C)
Second separate gas pump PN7133