PERMISSIBLE STRENTH OF STRUCTURAL BOLTS AS PER IS 800 : 2007

PROPERTY CLASS 4.6 6.8 8.8


BOLT DIA CROSS NET AREA TENSILE SHEAR SHEAR TENSILE SHEAR SHEAR TENSILE SHEAR SHEAR SLIP
(mm) AREA (mm^2) STRENGTH STRENGTH STRENGTH STRENGTH STRENGTH STRENGTH STRENGTH STRENGTH STRENGTH RESISTANCE
(mm^2) (KN) (KN) for (KN) for (KN) (KN) for (KN) for (KN) (KN) for (KN) for (KN)
single double single double single double
shear shear shear shear shear shear
12 113 88.22 31.76 16.30 32.60 47.64 24.45 48.90 63.52 32.60 65.19 7.90
16 201 156.83 56.46 28.98 57.95 84.69 43.46 86.93 112.92 57.95 115.90 14.05
20 314 245.04 88.22 45.27 90.55 132.32 67.91 135.82 183.05 93.94 187.89 22.78
25 491 382.88 137.84 70.74 141.48 206.76 106.11 212.22 286.01 146.79 293.57 35.59
32 804 627.31 225.83 115.90 231.80 338.75 173.85 347.70 468.60 240.49 480.99 58.32
36 1018 793.94 285.82 146.69 293.37 428.73 220.03 440.06 593.08 304.38 608.75 73.80

NOTE:
1) THE RATIO OF NET TENSILE AREA AT ROOT OF THREADS TO NOMINAL PLAIN SHANK OF THE BOLT TAKEN AS 0.78
2) ULTIMATE TENSILE STRESS FOR GRADE 4.6= 400 Mpa
6.8= 600 Mpa
8.8(d<=16)= 800 MPa
8.8 (d>16) =830 MPa
3) COEFFICIENT OF FRICTION ()= 0.20
4) NUMBER OF INTERFACES OFFERING FRICTIONAL RESISTANCE TO SLIP (n)=1
5) FASTENERS IN CLEARENCE HOLES (K) =1
6) ULTIMATE TENSILE STRESS FOR M.S PLATE= 410 Mpa
4.6, 6.6 & 8.8
BEARING STRENGTHS (KN) FOR M.S
PLATES OF THICKNESS

8 10 12 16 20
39.36 49.20 59.04 78.72 98.40
52.48 65.60 78.72 104.96 131.20
65.60 82.00 98.40 131.20 164.00
82.00 102.50 123.00 164.00 205.00
104.96 131.20 157.44 209.92 262.40
118.08 147.60 177.12 236.16 295.20