MATERIAL PROPERTY DATA

Concrete Compressive Strength, f'c = 30 Mpa


Reinforcement Yield Strength, Fy = 420 MPa

SIMPLIFIED COMPUTATION OF DEVELOPMENT LENGTH (DEFORMED BARS IN TENSION) ACI 318-08 12.2

No. 19 and
Spacing and cover smaller bars and No. 22 and larger
deformed wires bars

Clear spacing of bars or wires being


developed or spliced not less than db,
clear cover not less db, and stirrups or
ties throughout ld not less than the
Code minimum
or
( f )
y
2 .1 f'c
t e
db ( f )
y t
1 .7 f'c
e
db
Clear spacing of bars or wires being
developed or spliced not less than 2db
and clear cover not less than db

Other cases
( f )
y
1. 4 f'c
t e
db ( f )
y t
1 .1 f'c
e
db

Development length factors

Reinforcement location factor, t = 1.30 -for horizontal reinforcement placed more than 300mm above fresh concrete
Reinforcement coating factor, e = 1.00 -for uncoated and zic-coated (galvanized) bars
Modification factor, = 1.00 -for normalweight concrete

DEVELOPMENT LENGTH OF STANDARD HOOKS IN TENSION ACI 318-08 12.3

0.24
e fy d

8d b
l
150mm
(whichever is greater)
dh f' c b

Development length factors

Reinforcement coating factor, e = 1.00 -for other case


Modification factor, = 1.00 -for normalweight concrete

DEVELOPMENT LENGTH OF DEFORMED BARS IN COMPRESSION ACI 318-08 12.5

0.24fy
| db
ldc= f'c (whichever is greater)
|
|0.043fyd
Development length factors

Page 1 of 6
Zuhair Fayez Partnership- Asia Pacific
CALCULATION SHEET Job Number: J09-13000
Date: 10-Dec-17
Project: DESIGN OF GCCIA HEADQUARTER BUILDING Designed by: RDPB
-DAMMAM, KSA Checked by: EDS/UCC

Modification factor, = 1.00 -for normalweight concrete

SPLICE LENGTH OF DEFORMED BARS IN TENSION ACI 318-08 12.15

Splice Class Lap Splice Conditions

CLASS A SPLICE (Ld) If As provided 2 As required and percen As spliced


50

CLASS B SPLICE (1.3Ld) All other conditions

NOTE: Ld is the development length of deformed bar in tension but without the minimum of 300mm development length and
the modification factor for the excess reinforcement.

SPLICE LENGTH OF DEFORMED BARS IN COMPRESSION ACI 318-08 12.16

Splice Length Conditions

0.071f y d b for fy of 420 Mpa or less

(0.13fy-24)d b for fy greater than 420 Mpa

Splice Length * 1.3 for f'c less than 21 Mpa

MINIMUM DEVELOPMENT AND SPLICE LENGTHS (mm)

TENSION COMPRESSION

BAR SIZE TOP BARS (MIN. OF 300mm


(mm) DEVELOPMENT DEVELOPMENT CLASS A CLASS B CONCRETE CAST BELOW) DEVELOPMENT
COMPRESSION
LENGTH LENGTH SPLICE SPLICE LENGTH
SPLICE
Ld Ldh Ld 1.3Ld DEVELOPMENT CLASS A CLASS B Ldc
LENGTH SPLICE SPLICE

10 375 200 375 475 475 475 625 200 300

12 450 225 450 575 575 575 750 225 375

16 600 300 600 775 775 775 1000 300 500

20 750 375 750 950 950 950 1250 375 600

25 1150 475 1150 1475 1475 1475 1925 475 750

28 1275 525 1275 1650 1650 1650 2150 525 850

32 1450 600 1450 1900 1900 1900 2450 600 975

Page 2 of 6
Zuhair Fayez Partnership- Asia Pacific
CALCULATION SHEET Job Number: J09-13000
Date: 10-Dec-17
Project: DESIGN OF GCCIA HEADQUARTER BUILDING Designed by: RDPB
-DAMMAM, KSA Checked by: EDS/UCC

SIMPLIFIED COMPUTATION OF DEVELOPMENT AND SPLICE LENGTH OF DEFORMED BARS IN TENSION

Rebar Diameter 32 Modification factors

t 1.30 -for horizontal reinforcement placed more than 300mm above fresh concrete
Ld 1876.433
e 1.00 -for uncoated and zic-coated (galvanized) bars
1.00 -for normalweight concrete
Min. Ld 300
te 1.3 should not be greater than 1.7

Use Ld 1900 Reinforcement in excess of that required by analysis


1.00
Class A
Splice 1900

Class B
Splice 2450

DEVELOPMENT LENGTH OF STANDARD HOOKS IN TENSION

Rebar Diameter 32 Modification factors

e 1.00 -for other case


Ldh 588.911
1.00 -for normalweight concrete
Min. Ldh
256 For No. 36 bar and smaller hooks with side cover (normal to plane of hook) not less than
8db 65 mm, and for 90-degree hook with cover on bar extension beyond hook not less than
50 mm 1.00
Min. Ldh
150
150
For 90-degree hooks of No. 36 and smaller bars that are either enclosed within ties or
stirrups perpendicular to the bar being developed, spaced not greater than 3db along
Use Ldh 600 ldh; or enclosed within ties or stirrups parallel to the bar being developed, spaced not 1.00
greater than 3db along the length of the tail extension of the hook plus bend
NOTE: Min. Ldh is the greater of 8db and 150mm

For 180-degree hooks of No. 36 and smaller bars that are enclosed within ties or
stirrups perpendicular to the bar being developed, spaced not greater than 3db along
ldh 1.00

Where anchorage or development for fy is not specifically required, reinforcement in


excess of that required by analysis
1.00

DEVELOPMENT AND SPLICE LENGTH OF DEFORMED BARS IN COMPRESSION

Rebar Diameter 32 Modification factors

1.00 -for normalweight concrete


Ldc1 588.911
Reinforcement enclosed within spiral reinforcement not less than 6mm diameter and
Ldc2 577.920 not more than 100mm pitch or within No. 13 ties in conformance with 7.10.5 and 1.00
spaced at not more than 100 mm on center

Ldc 588.911 Reinforcement in excess of that required by analysis


1.00
Use Ldc 600

Splice 975
Length

Page 3 of 6
Zuhair Fayez Partnership- Asia Pacific
CALCULATION SHEET Job Number: J09-13000
Date: 10-Dec-17
Project: DESIGN OF GCCIA HEADQUARTER BUILDING Designed by: RDPB
-DAMMAM, KSA Checked by: EDS/UCC
Splice
Length 975

Page 4 of 6
Zuhair Fayez Partnership- Asia Pacific
CALCULATION SHEET Job Number:
Date: 10-Dec-17
Project: Designed by:
Checked by: