CORBEL FOR REPLACING THE BEARINGS (ACI 318M-08 )

Design information
Design shear V 1500 kN
Design tension force (min = 20%V) N 300 kN
Grade of concrete f'c 30 Mpa
Grade of steel fy 395 Mpa
Width of corbel b 500 mm
Total depth of corbel h 325 mm
Eccentricity of load V av 75 mm
Cover to main reinforcement co 50 mm
Assume Dia of Main reinforcement db 25 mm
Effective Depth d = h - co - db/2 262.5
Strength reduction factor (11.8.3.1) 0.75
Check av/d<1 OK
Flexure and Tension (11.8.3)
Design moment Mu = V*av+N*(h-d) 131.25 kN.m
Assume area of steel for flexure Af 2683 mm2
Check design moment and design capacity
Depth of equivalent rectangle stress block a=Af*fy/(0.85*fc*b) 83.1 mm
Flexure capacity of section *Mn=*Af*fy*(d-a/2) 175.6 kN.m
Check OK
Area of steel require for direct section tensile An=N/(*fy) 1013 mm2
Total area of steel required As = Af+An 3696 mm2
Design for shear (11.8.3.2 and 11.6)
Coefficient of friction m 1.4
Area of shear friction reinforcement required Afv = V/(*m*fy) 3617 mm2
Check OK
Design reinforcement (11.8.3.5, 11.8.3.4, 11.8.5)
Area of reinforcement shall be taken larger than (1) or (2)
(1) Af+An 3696 mm2
(2) 2*Afv/3+An 3424 mm2
Therefore , area of main Rein required Asc 3696 mm2
Choose the reinforcement : 6 Bars D28 Area : 3696 mm2
Minimum Area of Main Rein Asc = 0.04*fc*b*d/fy 399 mm2
Check OK
Area of stirrups to main reinforcement Ah = 0.5*(Asc-An) 1341.7 mm2