Professional Documents
Culture Documents
t
s
b
DATOS
b= 140 cm Mu(+)= 64.00 kN-m
ts= 25 cm Mu(-)= 0.00 kN-m
f'c= 280 kg/cm2 d= 16.55 cm
fy= 4200 kg/cm2 1= 0.85
ACERO POSITIVO
Suponiendo: c=d/5= 3.31 cm
a= 2.81 cm
= 0.90
Iterando
As(cm2/m)= 11.4 11.1 11.09
a(cm)= 2.01 1.96 1.96
c= 2.31
= 1.58 > 0.9
= 0.9 CORRECTO
Seleccin de la Varilla
1 1/2'' @ 0.12 m
1 5/8'' @ 0.18 m
SE USAR 1 3/4'' @ 0.26 m
1 1'' @ 0.46 m
1 13/8'' @ 0.91 m
1 1/2'' @ 0.15 m
REFUERZO MNIMO
fr= 33.63 kg/cm2 Min= 2.47 T-m
Sc= 6666.67 cm3 Mr= 2.92 T-m
Mcr= 2.47 T-m Min < Mr
1.33M= 85.12 T-m CORRECTO
conclusin:
ts
b
DATOS
b= 25 cm Mu(+)= 195.00 kN-m
ts= 80 cm Mu(-)= 0.00 kN-m
f'c= 280 kg/cm2 d= 38.00 cm
fy= 4200 kg/cm2 1= 0.85
ACERO POSITIVO
Suponiendo: c=d/5= 7.60 cm
a= 6.46 cm
= 0.90
Iterando
As(cm2)= 15.12 14.34 14.32
a(cm)= 2.67 2.53 2.53
c= 2.98
= 2.42 > 0.9
= 0.9 CORRECTO
Seleccin de la Varilla
1 1/2'' @ 0.09 m
1 5/8'' @ 0.14 m
1 3/4'' @ 0.20 m
1 1'' @ 0.36 m
1 13/8'' @ 0.70 m
SE USAR 1 1/2'' @ 0.15 m
REFUERZO MNIMO
fr= 33.63 kg/cm2 Min= 2.47 T-m
Sc= 6666.67 cm3 Mr= 11.76 T-m
Mcr= 2.47 T-m Min < Mr
1.33M= 259.35 T-m CORRECTO
conclusin:
@0.20m