Test Technology Test Method(s)


Emissions
Radiated & Conducted 47 CFR, FCC Part 15, Subpart B (using ANSI
C63.4-2009, ANSI C63.4-2014);
47 CFR, FCC Part 18 (using MP-5:1986);
AS/NZS CISPR 11; EN 55011; KN 11;
AS/NZS CISPR 13; EN 55013; KN 13;
AS/NZS CISPR 22; EN 55022; KN 22;
AS/NZS 3548; CNS 13438 (up to 6 GHz);
CISPR 32; EN 55032; KN 32;
AS/NZS 2297.1;
VCCI V-3 (up to 6 GHz)

Current Harmonics IEC 61000-3-2; EN 61000-3-2; KN 61000-3-2

Flicker IEC 61000-3-3; EN 61000-3-3; KN 61000-3-3

Immunity
Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; KN 61000-4-2

Radiated Immunity IEC 61000-4-3; EN 61000-4-3; KN 61000-4-3

Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4; KN 61000-4-4

Surge IEC 61000-4-5; EN 61000-4-5; KN 61000-4-5

Conducted Immunity IEC 61000-4-6; EN 61000-4-6; KN 61000-4-6

Power Frequency Magnetic IEC 61000-4-8; EN 61000-4-8; KN 61000-4-8


Field Immunity

Voltage Dips, Short Interruptions, IEC 61000-4-11; EN 61000-4-11; KN 61000-4-11


and Line Voltage Variations

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 1 of 9


Test Technology Test Method(s)
Specific Absorption Rate (SAR) IEEE Std 1528-2013; IEEE Std 1528a-2005;
KDB 865664; KDB 447498;
IEC 62209-1; IEC 62209-2;
EN 62209-1; EN 62209-2

Transmitters and Receivers 47 CFR, FCC Parts 2 and 15C/E (no DFS testing);
(below 40 GHz) KDB 905462;
ANSI C63.10:2009, ANSI C63.10:2013;
ANSI C63.26;
47 CFR, FCC Parts 20, 22, 24, 25, 27, 90, and
95, 97, 101;
ANSI/TIA-603-D;
RSS-GEN; RSS-102; RSS-119; RSS-129;
RSS-130; RSS-131; RSS-132; RSS-133;
RSS-139; RSS-199; RSS-210;
RSS-247 (no DFS testing); RSS-310;
ETSI TS 134 124; 3GPP TS 34.124;
ETSI TS 136 124; 3GPP TS 36.124;
ETSI TS 151 010-1, Section 12.2.2;
3GPP TS 51.010-1, Section 12.2.2;
PVG.04 V1.3.2

CTIA
Over the Air (OTA) CTIA Over the Air Test Plan, Release 3.5.2

CDMA CTIA CDMA Mobile Station Test Plan

3GPP2
Recommended Minimum Performance 3GPP2 C.S0011-C, (as required by the CCF test
Standards for cdma2000 Spread plan)
Spectrum Mobile Stations

Signaling Conformance Test Specification 3GPP2 C.S0031-0 (withdrawn by the CCF) 1;


for cdma2000 Spread Spectrum Systems 3GPP2 C.S0043 (as required by the CCF test plan);
3GPP2 C.S0062 (as required by the CCF test plan)

Recommended Minimum Performance 3GPP2 C.S0033-0 (as required by the CCF test plan)
Standards for cdma2000 High Rate
Packet Data Access Terminal

Recommended Minimum Performance 3GPP2 C.S0033-A (as required by the CCF test plan)
Standards for cdma2000 High Rate
Packet Data Access Terminal

Recommended Minimum Performance 3GPP2 C.S0036-0;


Specification for C.S0022-0 Spread 3GPP2 C.S0036-A (as required by the CCF test
Spectrum Mobile Stations plan)

Signaling Conformance Specification for 3GPP2 C.S0037-0 (as required by the CCF test plan)
cdma2000 Wireless IP Networks

Signaling Conformance Specification for 3GPP2 C.S0038-A;


cdma2000 High Rate Packet Data Air 3GPP2 C.S0038-B (as required by the CCF test plan)
Interface

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 2 of 9


Test Technology Test Method(s)
3GPP2 (cont.)
Electro-Acoustic Recommended 3GPP2 C.S0056-0 (as required by the CCF test plan)
Minimum Performance Specification for
cdma2000 Mobile Stations

Signaling Conformance Test 3GPP2 C.S0059-0 (as required by the CCF test plan)
Specification for cdma2000 Position
Determination Services

Signaling Conformance Test 3GPP2 C.S0060-0 (as required by the CCF test plan)
Specification for Over-the-Air Service
Provisioning

Signaling Conformance Test 3GPP2 C.S0061-0 (as required by the CCF test plan)
Specification for Short Message Service

Signaling Test Specification for Mobile 3GPP2 C.S0073-0;


Station Equipment Identifier (MEID) 3GPP2 C.S0073-B (as required by the CCF test plan)
Support for cdma2000 Spread Spectrum
Systems

Wireless [Universal Subscriber Identity 3GPP TS 31.121


Module (USIM) Application] Test
Specification

Wireless [Mobile Equipment (ME) 3GPP TS 31.124


Conformance Test Specification;
Universal Subscriber Identity Module
Application Toolkit (USAT)
Conformance Test Specification]

3rd Generation Partnership Project; 3GPP TS 37.571-1


Technical Specification Group Radio
Access Network; Universal Terrestrial
Radio Access (UTRA) and Evolved (E-
UTRA) and Evolved Packet Core (EPC);
User Equipment (UE) Conformance
Specification for UE Positioning; Part 1:
Conformance Test Specification

3rd Generation Partnership Project; 3GPP TS 37.571-2


Technical Specification Group Radio
Access Network; Universal Terrestrial
Radio Access (UTRA) and Evolved (E-
UTRA) and Evolved Packet Core (EPC);
User Equipment (UE) Conformance
Specification for UE Positioning; Part 2:
Protocol conformance

Evolved Universal Terrestrial Radio 3GPP TS 36.521-1


Access (E-UTRA); User Equipment (UE)
Conformance Specification; Radio
Transmission and Reception; Part 1:
Conformance Testing

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 3 of 9


Test Technology Test Method(s)
3GPP2 (cont.)
Evolved Universal Terrestrial Radio 3GPP TS 36.521-3
Access (E-UTRA); User Equipment (UE)
Conformance Specification; Radio
Transmission and Reception; Part 3:
Radio Resource Management (RRM)
Conformance Testing

Evolved Universal Terrestrial Radio 3GPP TS 36.523-1


Access (E-UTRA) and Evolved Packet
Core (EPC); User Equipment (UE)
Conformance Specification;
Part 1: Protocol Conformance
Specification

Verizon Wireless Test Plans


Verizon, LTE Supplementary Signaling Verizon, LTE Supplementary Signaling
Conformance Test Plan Device Test Plan Conformance Test Plan Device Test Plan

Verizon, LTE 3GPP Band 13 Verizon, LTE 3GPP Band 13 Supplementary


Supplementary RF Conformance Device RF Conformance Device Test Plan
Test Plan

Verizon, LTE 3GPP Carrier Aggregation Verizon, LTE 3GPP Carrier Aggregation
Supplementary RF Conformance Device Supplementary RF Conformance Device Test
Test Plan Plan

Verizon, LTE 3GPP Band 2 Supplementary Verizon, LTE 3GPP Band 2 Supplementary
RF Conformance Device Test Plan RF Conformance Device Test Plan

Verizon, LTE 3GPP Band 13 Verizon, LTE 3GPP Band 13 Supplementary


Supplementary RRM Conformance Device RRM Conformance Device Test Plan
Test Plan

Verizon, LTE Data Retry Device Test Plan Verizon, LTE Data Retry Device Test Plan

Verizon, LTE 3GPP Band 13 Data Verizon, LTE 3GPP Band 13 Data
Throughput Device Test Plan Throughput Device Test Plan

Verizon, LTE SMS Device Test Plan Verizon, LTE SMS Device Test Plan

Verizon, LTE Device-UICC USIMISIM Verizon, LTE Device-UICC USIMISIM


Interaction Device Test Plan Interaction Device Test Plan

Verizon, LTE AT commands for Test Verizon, LTE AT commands for Test
Automation Device Test Plan Automation Device Test Plan

Verizon, LTE IMS Registration and Retry Verizon, LTE IMS Registration and Retry
Device Test Plan Device Test Plan

Verizon, LTE PCO Test Plan Device Test Verizon, LTE PCO Test Plan Device Test Plan
Plan

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 4 of 9


Test Technology Test Method(s)
Verizon Wireless Test Plans (cont.)
Verizon, LTE 3GPP Band 4 Supplementary Verizon, LTE 3GPP Band 4 Supplementary
RF Conformance Device Test Plan RF Conformance Device Test Plan

Verizon, LTE 3GPP Band 5 Supplementary Verizon, LTE 3GPP Band 5 Supplementary
RF Conformance Device Test Plan RF Conformance Device Test Plan

Verizon, LTE Interband Device Test Plan Verizon, LTE Interband Device Test Plan

Verizon, LTE 3GPP Band4 Data Verizon, LTE 3GPP Band4 Data Throughput
Throughput Device Test Plan Device Test Plan

Verizon, IMS VoIP Test Plan Device Test Verizon, IMS VoIP Test Plan Device Test
Plan Plan

Verizon, LTE TestPlan Rich Comm Verizon, LTE Test Plan Rich Comm Services
Services Device Test Plan Device Test Plan

Verizon, e911 for LTE Only Or LTE Verizon, e911 for LTE Only Or LTE Multi-Mode
Multi-Mode VoLTE Capable Devices VoLTE Capable Devices Device Test Plan
Device Test Plan

Verizon, VoLTE 1XRTT Fallback Test Verizon, VoLTE 1XRTT Fallback Test Plan
Plan Device Test Plan Device Test Plan

Verizon, hVoLTE Compliance Test Plan Verizon, hVoLTE Compliance Test Plan
Device Test Plan Device Test Plan

Verizon, LTE Over the Air Radiated Verizon, LTE Over the Air Radiated
Performance Device Test Plan Performance Device Test Plan

Verizon, Android Platform Test Plan Verizon, Android Platform Test Plan Device
Device Test Plan Test Plan

Verizon, OTA Radiated Performance for Verizon, OTA Radiated Performance for
CDMA and LTE MM Device Test Plan CDMA and LTE MM Device Test Plan

Verizon, 1x RF Parametric Device Test Verizon, 1x RF Parametric Device Test Plan


Plan

Verizon, 1xEV-DO Device Test Plan Verizon, 1xEV-DO Device Test Plan

Verizon, DEVICE COMPLIANCE TEST Verizon, DEVICE COMPLIANCE TEST


PLAN: 1XEV-DO A12 PLAN: 1XEV-DO A12

Verizon, CMAS Device Test Plan Verizon, CMAS Device Test Plan

Verizon, Data Session - Throttling and Verizon, Data Session - Throttling and Retry
Retry Device Test Plan Device Test Plan

Verizon, Data Throughput Lab Device Verizon, Data Throughput Lab Device Test
Test Plan Plan

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 5 of 9


Test Technology Test Method(s)
Verizon Wireless Test Plans (cont.)
Verizon, COMPLIANCE TEST PLAN Verizon, COMPLIANCE TEST PLAN E911 -
E911 - CALL PROCESSING CALL PROCESSING

Verizon, COMPLIANCE TEST PLAN Verizon, COMPLIANCE TEST PLAN


ENHANCED ROAMING INDICATOR ENHANCED ROAMING INDICATOR

Verizon, COMPLIANCE TEST PLAN Verizon, COMPLIANCE TEST PLAN


GLOBAL SYSTEM DETERMINATION GLOBAL SYSTEM DETERMINATION
FOR GLOBAL DEVICES FOR GLOBAL DEVICES

Verizon, Location Determination Device Verizon, Location Determination Device Test


Test Plan Plan

Verizon, COMPLIANCE TEST PLAN: Verizon, COMPLIANCE TEST PLAN:


MOBILE IP MOBILE IP

Verizon, OTAPA Device Test Plan Verizon, OTAPA Device Test Plan

Verizon, OTASP Device Test Plan Verizon, OTASP Device Test Plan

Verizon, COMPLIANCE TEST PLAN Verizon, COMPLIANCE TEST PLAN SAFE


SAFE FOR NETWORK TESTING FOR NETWORK TESTING

Verizon, System Acquisition 1x-EVDO Verizon, System Acquisition 1x-EVDO


Device Test Plan Device Test Plan

Verizon, System Acquisition Test Plan Verizon, System Acquisition Test Plan Device
Device Test Plan Test Plan

Verizon, Wireless Priority Services Verizon, Wireless Priority Services (WPS)


(WPS) Device Test Plan Device Test Plan

Verizon, LTE OTADM Test Plan Verizon, LTE OTADM Test Plan Device Test
Device Test Plan Plan

Verizon, LTE-CDMA InterRAT Verizon, LTE-CDMA InterRAT Performance


Performance Device Test Plan Device Test Plan

Verizon, COMPLIANCE TEST PLAN Verizon, COMPLIANCE TEST PLAN FOR


FOR EHRPD EHRPD

Verizon, iRAT Test Plan SVD Device Verizon, iRAT Test Plan SVD Device Test
Test Plan Plan

Verizon, Domestic FIT Test Plan Verizon, Domestic FIT Test Plan Device Test
Device Test Plan Plan

Verizon, Global FIT Test plan for Verizon, Global FIT Test plan for Canada
Canada Device Test Plan Device Test Plan

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 6 of 9


Test Technology Test Method(s)
Radio Communication ETSI EN 301 489-1; KN 301 489-01;
ETSI EN 301 489-3; KN 301 489-03;
ETSI EN 301 489-7; KN 301 489-05;
ETSI EN 301 489-17; KN 301 489-17;
ETSI EN 301 489-24; KN 301 489-24

Wireless (UICC Terminal ETSI TS 102 230


Interface; Physical, Electrical and
Logical Test Specification

NEBS
Electrostatic Discharge (ESD) GR-1089-CORE, Section 2

Emissions GR-1089-CORE, Section 3

Immunity GR-1089-CORE, Section 3

Power Cross GR-1089-CORE, Section 4

Lightning GR-1089-CORE, Section 4

Steady State Induction GR-1089-CORE, Section 5

DC Potential GR-1089-CORE, Section 6

Electrical Safety GR-1089-CORE, Section 7

Corrosion GR-1089-CORE, Section 8

Bonding & Grounding GR-1089-CORE, Section 9;


GR-487-CORE, Section 3.15

Criteria for DC Power Ports GR-1089-CORE, Section 10

Spatial GR-63-CORE, Section 2.0

Temperature/Humidity/Altitude GR-63-CORE, Section 4.1;


GR-487-CORE, Sections 3.27 and 3.34

Needle Flame GR-63-CORE, Section 4.2

Flammability GR-63-CORE, Section 4.2

Equipment Handling GR-63-CORE, Section 4.3

Earthquake GR-63-CORE, Section 4.4;


GR-487-CORE, Section 3.35

Airborne Contaminates GR-63-CORE, Section 4.5

Hygroscopic Dust GR-63-CORE, Section 4.5

Acoustics GR-63-CORE, Section 4.6;


GR-487-CORE, Section 3.29

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 7 of 9


Test Technology Test Method(s)
NEBS (cont.)
Illumination GR-63-CORE, Section 4.7

Salt Fog GR-487-CORE, Section 3.34

Wind Driven Rain GR-487-CORE, Section 3.28

Product Specific Standards


Household Appliances IEC 55014-1; EN 55014-1;
AS/NZS CISPR 14-1; KN 14-1;
AS/NZS CISPR 14-2; EN 55014-2; KN 14-2

Laboratory Equipment IEC 61326; EN 61326

Medical Equipment IEC 60601-1-2; EN 60601-1-2

ITE/Telco Equipment AS/NZS/CISPR24; EN55024; KN 24

Light Industrial IEC 61000-6-1; EN 61000-6-1; KN 61000-6-1;


IEC 61000-6-3; EN 61000-6-3; KN 61000-6-3

Heavy Industrial IEC 61000-6-2; EN 61000-6-2; KN 61000-6-2;


IEC 61000-6-4; EN 61000-6-4; KN 61000-6-4

Multimedia Equipment KN 35 (2013-06)

Telco Equipment ETSI EN 300 386

Gas Sensors IEC 50270; EN 50270

Professional A/V IEC 55103-1; EN 55103-1;


IEC 55103-2; EN 55103-2

EV Charging Stations UL 2231-2 (Section 22)

Wireless2
GSM, UMTS, LTE GSMA TS11: Device Field and Lab Test
Guidelines

GSM, UMTS, LTE GSMA TS11: Device Field and Lab Test
Guidelines (2013)

CDMA, EVDO, LTE VZW Compliance Test Plan: Domestic Field


Interoperability Testing (FIT)

CDMA, EVDO, LTE VZW Compliance Test Plan: Domestic Field


Interoperability Testing (FIT) (2013)

On the following products or types of products:


Telco Control Office Equipment, Outside Plant, Customer Premise Equipment

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 8 of 9


1
Note: This laboratorys scope contains withdrawn or superseded methods. As a clarifier, this indicates
that the applicable method itself has been withdrawn or is now considered historical and not that the
laboratorys accreditation for the method has been withdrawn.
2
This laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field
Calibration Laboratories for these tests.

Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in


Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.13:

Rule Subpart/Technology Test Method Maximum


Frequency
Unintentional Radiators
Part 15B ANSI C63.4:2014 40 GHz

Industrial, Scientific, and Medical Equipment


Part 18 FCC MP-5 (February 1986) 40 GHz

Intentional Radiators
Part 15C ANSI C63.10:2013 40 GHz

U-NIII without DFS Intentional Radiators


Part 15E ANSI C63.10:2013 40 GHz

Commercial Mobile Services (FCC Licensed


Radio Service Equipment)
Parts 22 (cellular), 24, 25 (non-microwave), ANSI/TIA-603-D 40 GHz
and 27

General Mobile Radio Services (FCC


Licensed Radio Service Equipment)
Parts 22 (non-cellular), 90 (non-microwave), ANSI/TIA-603-D 40 GHz
95, 97, and 101 (non-microwave)

RF Exposure
Devices Subject to SAR Requirements IEEE Std 1528:2013 6 GHz

3
Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the
FCC website (https://apps.fcc.gov/oetcf/eas/) for a listing of FCC approved laboratories.

(A2LA Cert. No. 1926.01) Revised 06/26/2017 Page 9 of 9


Accredited Laboratory
A2LA has accredited

INTERTEK TESTING SERVICES NA


Lexington, KY
for technical competence in the field of

Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqu dated 8 January 2009).

Presented this 10th day of May 2016.

_______________________
President and CEO
For the Accreditation Council
Certificate Number 1926.01
Valid to April 30, 2018
Revised June 26, 2017

For the tests to which this accreditation applies, please refer to the laboratorys Electrical Scope of Accreditation.