PORTABLE - Up to two or three times lighter than similar devices from our competitors.
PRACTICAL - Can use lighter/thinner cables.
USER-FRIENDLY - Completely automated sage in test processes.
EFFICIENT - Modern switch techniques, power electronics, sophisticated design.
ACCURATE - Typical accuracy of our products is 0,1 %.
ROBUST - Our devices are built in metal or plastic cases. The rigid design makes our products ideal
for use in high voltage substations and industrial environments.
COMPLIANT - IEC and other applicable international standards, CE approved.
www.dv-power.com 3
Circuit Breaker
LOREM IPSUM Test Equipment
\ IPSUM LOREM
The High DC Current Micro Ohmmeters RMO-A series instruments are designed to provide safer, faster and easier
resistance measurements of:
RMO-A Series
RMO100A
RMO200A
RMO300A
RMO400A
RMO500A
RMO600A
RMO60E (Earthing)
The High DC Current Micro Ohmmeters RMO-G series instruments are mounted in plastic housings and have an
additional Both Sides Grounded feature as an extension to its versatile list of measurement possibilities.
RMO-G Series
RMO100G
RMO200G
RMO300G
RMO400G
RMO500G
RMO600G
RMO800G
During the HV circuit breaker contact resistance measurement, an efcient way of insuring
protection from the induced voltages is to ground the tested circuit breaker on both sides.
RMO-G series instruments have the possibility to perform measurements with both sides of
a test device grounded. This will ensure the safety of the operators and protect the instrument
as well. The gure on the right, presents the connection diagram of the instrument to the high
voltage circuit breaker with both sides grounded.
The High DC Current Micro Ohmmeters RMO-D series instruments are the most advanced version of RMO-G series
instruments. The additional feature is the ability to perform fully automatic demagnetization of a current transformer core
after the measurement. Demagnetizing a magnetic core of a current transformer requires alternating current to be applied
with a decreasing magnitude down to zero. Using the proprietary solution design the RMO-D series instruments provide the
appropriate magnitudes and alternates by internally changing the polarity of a controlled DC current.
www.dv-power.com 5
Circuit Breaker
LOREM IPSUM Test Equipment
\ IPSUM LOREM
The Coil Analyzer SAT series instruments are ideal for testing circuit breakers, where
substation battery is not connected or available. These devices are compatible with
breaker analyzers from different vendors and eliminate use of station batteries during
testing. An additionally provided feature on these types of the DV Power instruments is
a signicant reduction of testing time when using our CAT and SAT devices together.
Power Output
Coils output DC voltage 10 V DC - 300 V DC
Coils output AC voltage 10 V AC - 250 V AC
Motor output DC voltage 10 V DC - 250 V DC
Coil resistance measurement
Measuring range Resolution
0,5 - 99,9 0,1 Highlights
100 - 999 1
Minimum trip voltage - Lightweight only 9,20 kg
fully automatic test Coil current measurement
Start voltage 10 V - 299 V DC; 10 V - 249 V AC Coil resistance measurement
Minimum trip voltage test
Stop voltage 11 V - 300 V DC; 11 V - 250 V AC
of the circuit breaker's coils
Step voltage 1 V - 20 V DC; 1 V - 20 V AC Undervoltage release test
Typical accuracy (0,25 % rdg + 0,25 % FS) Supplying spring-charging motors
Providing a power supply for
Operating temperature -10 C + 50 C
breaker analyzers from different vendors
The Coil Tester & Breaker Supply POB series instruments are the variable voltage power supply units ideal for testing circuit
breakers, where substation battery is not connected or available. They are intended for operating breaker coils, and spring-
charging motors as a part of commissioning and maintenance testing. These devices are compatible with breaker analyzers
from different vendors and eliminate use of station batteries during testing.
Circuit Breaker Analyzer & Timer CAT series are standalone or PC controlled digital instruments for a condition assessment of
circuit breakers. A simultaneous measurement of up to 12 main contacts (4 breaks per a phase) including pre-insertion resistors
and 6 auxiliary contacts. CAT series instruments record graphs of both, the open and close coil currents and displacements
of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-
insertion resistors (if present in the circuit breaker).
www.dv-power.com 7
Circuit Breaker Test Equipment
Two CAT Device Series
The rst series of CAT instruments was designed to meet requirements of an easy to use circuit breaker analyzer & timer
with an attractive price. Their primary intention was timing and motion measurement of HV and MV circuit breakers.
Series 1 CAT03 CAT31 CAT34 CAT61 CAT64
Main contacts and 3 3 3 6 6
preinsertion
resistors contacts
timing channels
Auxiliary contacts NO 3 3 3 3
timing channels
BSG feature enables safe and fast testing in high voltage substations,
without removing the safety ground connections on both sides of the
circuit breaker. No additional modules or remote boxes are required.
Each main contacts timing channel is able to detect main contacts state
in a case when both terminals are grounded.
The built-in micro ohmmeter generates a true DC ripple free current with an
automatically regulated test ramps. The resistance measurement is using
the well known .elvins four points method. The DC current is generated
through the closed circuit breaker contacts. The voltage drop is measured
between the terminals of the circuit breakers. The resistance is calculated
using the Ohms law R U/I.
The built-in micro ohmmeter can also be used for the DRM. The DRM test is performed by injecting a current through the
breaker contact and simultaneously monitoring the voltage drop across the breaker contact as well as the current ow during
the operation of the breaker. Resistance curve as a function of contact travel can be used to reveal failures in relation to the
arcing contact condition. The test current should be at least 100 A to provide a higher voltage drop to allow easier detection
of the arcing contact. The DRM test requires the circuit breaker analyzer with a high resolution measurement.
After a DC current test of a circuit breaker or bus-bars, the magnetic core of associated current transformers may be magnetized
(remanent magnetism). To eliminate this source of potential problems, demagnetization should be performed. Following the
apparatus resistance measurements, there is a possibility to start the demagnetization process using this instrument. The
whole demagnetization process is performed automaticaly and does not require modication of any connections.
www.dv-power.com 9
Transformer Test Equipment
The Winding Ohmmeters RMO-TT, -TD and -TW series are designed for the winding resistance measurement of inductive test
objects (transformers/generators/motors) and for the on-load tap changer analysis of power transformers. Typical application
areas of RMO-TT, -TD and -TW are high-voltage substations and industrial environments.
Transformers
Measuring the winding resistance is an
Generators/motors
important part of commissioning,
Electrical machines
maintaining and production of:
High-current busbar joints
Cable splices
All the RMO-TT, -TD and -TW instruments have a resistance measurement accuracy of up to 0,1%. This enables a very
reliable determination of the transformer condition. The open circuit voltage of up to 60 V enables a very short transformer
charging time. The instruments generate a true DC ripple-free current.
The DV-Win software (included in the purchase price) provides additional analysis options, such as creation of test reports,
static and dynamic resistance graphs, measurement of the tap changer transition times, the result download, as well as many
other features. A Heat Run resistance/temperature extrapolation can also be performed using the software for the RMO-TT
instruments.
The instruments from the RMO-TT and RMO-TD series also have the automatic demagnetization feature. The process
is completely safe, fully automated and very fast. This enables the user to avoid problems such as high inrush currents at
the start-up of power transformers, incorrect operation of protective relays, erroneous diagnostics or inaccurate electrical
measurement on a transformer.
Tap Changer Analyzer & Winding Ohmmeter Tap Changer Analyzer & Winding Ohmmeter RMO60TD
RMO60TT
Two resistance measurement channels
Three resistance measurements channels Test current 5 mA 60 A DC
Test current 5 mA 60 A DC On-load tap changer dynamic resistance measurement
Three temperature measurement channels Rapid automatic demagnetization
Automatic resistance/temperature measurement Tap changer motor current monitoring channel
for the Heat Run test Measuring range 0,1 2 k
On-load tap changer dynamic resistance measurement Automatic discharge process
Rapid automatic demagnetization Built-in tap changer control unit
AC Current monitoring channel for USB ash drive feature
tap changer motor current measurement
Measuring range 0,1 2 k
Automatic discharge process
Built-in tap changer control unit
USB ash drive feature
Winding Ohmmeter RMO50TW
Tap-Changer & Winding Analyzer TWA30D is a one-of-a-kind diagnostic solution for power transformer testing. Using this
device, the transformer testing is safer, signicantly faster, and more convenient. The TWA30D instrument is designed
for simultaneous three-phase tap changer analysis and six-winding resistance measurement of both the primary and the
secondary transformer windings.
The measurement is obtained very quickly by saturating all three legs of the magnetic core at the same time. Once all 6-8
bushings are connected and the transformer conguration selected, the instrument adjusts the test procedure automatically.
The TWA30D generates a true DC ripple-free current. The injection of current and the discharge of energy from the magnetic
circuit are both automatically regulated.
Dynamic resistance graphs are recorded for all three phases simultaneously, so the synchronization is veried using the
cursors provided in the DV-Win software. All three phase traces are plotted on the same graph. In addition, the tap changer
motor current is recorded, and displayed on the same graph. The measurement is completed quickly even on the largest
power transformers. Each vector group has a special measurement algorithm which is optimized for the fast stabilization of
test results.
Interchangeable Cables with the TRT63 Three - Phase Transformer Turns Ratio Testers
The test cables used for the measurement are completely compatible with the DV Power TRT instruments. This enables the
user to measure, with a single connection of the test leads:
www.dv-power.com 11
Transformer Test Equipment
Due to their unique capabilities, the TWA30D and RMO-T series instruments are the best on-load tap changer analyzers in
the market today. A tap changer analysis can be performed either by the stand-alone instruments, or in a combination with the
DV-Win software. When used together with the DV-Win software, they enable the measurement of:
The TWA30D instruments enable simultaneous OLTC testing of all three phases in a
single pass through the tap positions. In this manner, the total OLTC testing time is greatly
shortened, by two thirds in comparison with the classic methods. This test procedure also
enables observing the synchronization problems between the different phases.
The static resistance measurement provides winding resistance values on all tap positions
for each of the three phases. There is no need to discharge the transformer between the
measurements in different tap positions. The DV-Win software enables creating the static
resistance graph from the results of the resistance measurement in different positions,
as well as the automatic recalculation of the measured values to a reference temperature
value. The shape of the static resistance graph depends on the winding regulation mode.
The dynamic resistance measurement (DRM) feature enables measuring and recording of the test current at high sampling
rate during the tap change transition. The variation of the current represents the change of the resistance in the circuit during
the change of the tap positions. Tap changer verication can be performed in the DV-Win software or on the stand-alone
TWA30D or RMO-T instruments. The stand-alone instruments detect any open circuits during the tap changer operation.
The dynamic resistance measurement graph is unique, and above all, powerful tool that provides condition assessment of
an OLTC regarding the mechanism itself and its contact wear. It is recorded by the DV-Win software. The innovative graph
analysis tools enable the detection of:
The AC current monitoring channel enables monitoring and recording the OLTC mechanical-drive motor current during the
tap changer operation. The motor-current waveform is also printed on the same DV-Win-generated graph, and can help in
detecting OLTC mechanical problems.
The OLTC transition times, as well as the percentage of a current drop during transitions (known as the transition ripples), are
recorded numerically. The DV-Win software records these values
in the Test Report together with the static winding resistance
values. It is possible to save the Test Report in various formats,
such as PDF, XLS, DOC, etc.
The TRT is a true three-phase, fully automatic test set, specially designed for a turns ratio, a phase shift and an excitation
current measurement of power, distribution and instrument transformers. The TRT determines the transformer turns
ratio by accurately measuring the voltages across the unloaded transformer windings. Following these measurements it
displays the ratio of these voltages.
All the TRT devices are equipped with a tap changer control unit which allows changing tap positions remotely. USB Flash
Drive feature enables saving all the test results to a USB memory stick. DV Power provides 112 mm built-in thermal printer
as an option.
Main Features
TRUE THREE-PHASE A true three-phase excitation voltage is applied to the three transformer primary windings.
Three induced phase voltages are measured at the same time. In such a way it is possible to detect the phase angle and
measure the turns ratio of any transformer type, including phase shifting transformers, where other three-phase turns
ratio testers cannot.
The TRT63 series is upgraded to use the same cable set as the Tap Changer & Winding Analyzer TWA30D, which
enables a one-time cable setup. This makes TRT63 and TWA30D one combined measurement system.
Test voltage TRT03A TRT03B TRT03C
Single phase 8/40/100 V AC 10/40/100 V AC 8/40/80 V AC
www.dv-power.com 13
Transformer
LOREM IPSUMTest Equipment
\ IPSUM LOREM
Main features:
The new DEM60C instrument replaces the model DEM60, with an additional
feature of displaying and monitoring the demagnetization process in real time.
The generated graph can be saved on a computer. This option provides easy
after-the-test analysis of the demagnetization process, in terms of current
waveforms and values for each step, along with duration of the complete
process.
The Winding Ohmmeters RMO50M and RMO100M are designed for winding resistance mea-
surement of motors and generators. Built-in discharging circuit is designed for energy dis-
charge of motors and generators. Using DV-Win software a test can be performed from a PC
and the results can be obtained directly at a PC.
Main Features
Lightweight - only 8 kg
Test current 10 mA 100 A DC
Measuring range 0,1 - 600
Extremely quick measurement
Mechanical protection IP43
Accessories - a Selection
Current cables 2 x 10 m 10 mm2 and Sense cables 2 x 10 m with TTA clamps Shunts
Sense cables 2 x 10 m with TTA clamps
DV-Win Software