You are on page 1of 1

COLUMN COLUMN COLUMN

SPAN SPAN SPAN

L1 (REFER TO SCHEDULE OF BEAMS AND GIRDERS L2 (REFER TO SCHEDULE OF BEAMS AND GIRDERS L1 (REFER TO SCHEDULE OF BEAMS AND GIRDERS SPLICE ZONE FOR L2 (REFER TO SCHEDULE OF BEAMS AND GIRDERS

GIRDER TOP BARS

SPLICE LENGTH
SEE TABLE

SPLICE LENGTH T
EQ. EQ. TOP BARS SEE TABLE
AT SUPPORT CONTINUOUS
TOP BARS AT EQ. EQ.
WEB BARS
TOP BARS A

40mm COVER
CANTILEVER'S TOP BARS TOP BARS

(TYPICAL)
AT MIDSPAN B
DISCONTINUOUS AT SUPPORT AT MIDSPAN
END
d

40mm COVER
(TYPICAL)
BOTTOM BARS BOTTOM BARS
2d EQ. EQ. EQ. EQ.
AT SUPPORT AT MIDSPAN 2d 2d
B
L3 (REFER TO SCHEDULE OF BEAMS AND GIRDERS L4 (REFER TO SCHEDULE OF BEAMS AND GIRDERS L3 (REFER TO SCHEDULE OF BEAMS AND GIRDERS L4 (REFER TO SCHEDULE OF BEAMS AND GIRDERS

BOTTOM BARS
AT CANTILEVER'S A
DISCONTINUOUS 50mm MAX.
AT SUPPORT B
END
B
HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT

SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE


DISCONTINUOUS END
DISCONTINUOUS CONTINUOUS END CONTINUOUS END
FREE END

NOTES:
1. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE LARGER SIZE AND
ELEVATION
NUMBER OF TOP AND BOTTOM BARS FROM ADJACENT SPAN.
2. NO SPLICE SHALL BE ALLOWED 2d FROM THE FACE OF THE SUPPORT TYPICAL DUCTILE MOMENT FRAME