You are on page 1of 3

Data Sheet

GT2­71D
Amplifier Unit, Pulse Output Type

SPECIFICATIONS

Model GT2­71D

Mounting method DIN rail mount

Power supply voltage 10 to 30 VDC, including 10 % ripple (P­P), Class 2

Rating Power consumption 1,600 mW or less (at 30 V: 53.3 mA or less)

Number of expandable units Cannot be extended

Indicator lamp Power (green), alarm (red), pulse output (green), input (green)

Pulse resolution 0.1 μm 0.004 Mil, 0.5 μm 0.02 Mil, 1 μm 0.04 Mil, 10 μm 0.039 Mil (selectable)

Minimum phase difference 0.5 μs, 2.5 μs, 5 μs, 25 μs (selectable)

Control input origin return No­voltage input (with contacts, without contacts), input time: 20 ms or more

Output signal 90 ° phase difference from the A, B, and Z phases; differential square wave (conforms to EIA­422)

Output signal level +5 V

Environmental resistance Ambient temperature ­10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity 35 to 85 % RH (No condensation)

Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Materials Polycarbonate (PC)

Weight Approx. 110 g (including the power supply cable)

KEYENCE AMERICA 1­888­KEYENCE(Toll Free) http://www.keyence.com/ 2017/12/06 Page:1/3


Data Sheet

Dimensions

KEYENCE AMERICA 1­888­KEYENCE(Toll Free) http://www.keyence.com/ 2017/12/06 Page:2/3


Data Sheet

I/O Circuit Connection diagram

Pulse output amplifier unit (GT2­71D)
I/O circuit

* For details of the external input, refer to the diagram of the external input circuit.

Pulse output amplifier unit (GT2­71D)
External input circuit
Recommended input device

KEYENCE AMERICA 1­888­KEYENCE(Toll Free) http://www.keyence.com/ 2017/12/06 Page:3/3