You are on page 1of 4

THM Gas Turbine Family

Performance
Data
The THM
Gas Turbine Range

All THM gas turbines are available Excellent part load emissions without Each THM can, as an option, be equip-
either with their standard combustion any efficiency penalty are achieved by ped with a recuperator heat exchanger
system for gaseous and liquid fuels using an patented air-bypass system; where the hot exhaust gas flow heats
(water or steam injection can be used part of the compressor air bypasses the compressor discharge air before
for NOX control) or with a Dry-Low-NoX the combustion zone and reenters entering the combustion system.
System. the process upstream of the turbine
section. This leads to a significant fuel saving.
For THM 1304 gas turbines equipped
with the Dry-Low-NOX (DLN) combus- Optimum fuel/air ratio in the lean com- Output power rating curves for the
tion system, NOX and CO emissions bustion zone is therefore possible over THM models 1203A, 1304-9, 1304-10
below 25 ppmv (dry, 15% O2) are a wide load range without the need to and 1304-11 are shown in Figures 1 to
achieved on natural gas fuel over a blow off compressor air. 4 for mechanical drive and for gener-
wide load range. ator drive applications.

1203A 1304-9 1304-10 1304-11


Mechanical Drive (at Coupling)
Power Output kW 6000 9000 9700 11200
Efficiency % 23.4 28.8 29.2 31.0
Heat Rate kJ/kWh 15380 12500 12330 11610
Generator Drive (at Generator Terminals)
Power Output kWe 5760 8640 9320 10760
Efficiency % 22.5 27.7 28.0 29.8
Heat Rate kJ/kWh 16020 13020 12840 12090
Exhaust Data
Exhaust Gas Temperature °C 515 492 500 505
Exhaust Gas Flow kg/s 35.2 44.9 45.3 49.1

1203A 1304-9 1304-10 1304-11


Mechanical Drive (at Coupling)
Power Output hp 8050 12070 13010 15020
Efficiency % 23.4 28.8 29.2 31.0
Heat Rate Btu/hph 10870 8835 8715 8206
Generator Drive (at Generator Terminals)
Power Output kWe 5760 8640 9320 10760
Efficiency % 22.5 27.7 28.0 29.8
Heat Rate Btu/kWh 15180 12341 12170 11459
Exhaust Data
Exhaust Gas Temperature °F 959 918 932 941
Exhaust Gas Flow lb/s 78 99 100 108

All Data at 15°C (59°F), Sea Level (101.3 kPa), Rel. Humidity 60%, Zero Inlet and Exhaust Pressure Losses.
For Generator Drive: Gearbox Efficiency 98.5%, Generator Efficiency 97.5%.
THM 1203A Rating THM 1304-9 Rating
7 11
9000
14000
10
Output Power [MW]

Output Power [MW]


1.)
Shaft power

Output Power [hp]

Output Power [hp]


6 8000 13000
Shaft power 1.)
9 12000
Electric power 2.) 7000
5
11000
8
6000 Electric power 2.)
10000
4
5000 7
9000

3 6
-15 -5 5 15 25 35 45 -15 -5 5 15 25 35 45
(5) (23) (41) (59) (77) (95) (113) (5) (23) (41) (59) (77) (95) (113)

Inlet Air Temperature [°C] / [°F] Inlet Air Temperature [°C] / [°F]

Figure 1 Figure 2

THM 1304-10 Rating THM 1304-11 Rating


11 12

14000 Shaft power 1.)


Shaft power 1.) 15000
11
Output Power [MW]

Output Power [MW]


Output Power [hp]

Output Power [hp]


10
13000 14000
Electric power 2.)
10
13000
9 Electric power 2.) 12000
9 12000
11000
8 11000
8
10000 10000
7 7
-15 -5 5 15 25 35 45 -15 -5 5 15 25 35 45
(5) (23) (41) (59) (77) (95) (113) (5) (23) (41) (59) (77) (95) (113)

Inlet Air Temperature [°C] / [°F] Inlet Air Temperature [°C] / [°F]

Figure 3 Figure 4

Power Output vs. Inlet Temperature

Sea Level (101.3 kPa), Rel. Humidity 60%, Zero Inlet and Exhaust Pressure Losses

1.) Power Output on Gas Turbine Shaft


2.) Power Output at Generator Terminals (Generator Efficiency 97.5%, Gearbox Efficiency 98.5%)

Note: Due to the continued upgrading/uprating process of THM turbines performance data are subject to change
MAN Turbomaschinen AG MAN Turbomaschinen AG In the interests of technical progress,
GHH BORSIG GHH BORSIG this publication is subject to revision
Steinbrinkstrasse 1 Egellsstrasse 21 without notice.
46145 Oberhausen / Germany 13507 Berlin / Germany Printed in Germany.
Phone +49. 208. 6 92-01 Phone +49. 30. 43 01-03 January 2002
Fax +49. 208. 6 92-20 19 Fax +49. 30. 43 01-28 41 TURBO 922 e 0102 1,5 ba
www.manturbo.com

MAN Turbomaschinen AG MAN Turbomacchine S.r.l.


Schweiz De Pretto
Hardstrasse 319 Via Daniele Manin 16/18
8023 Zurich / Switzerland 36015 Schio (VI) / Italy
Phone +41. 1. 278-22 11 Phone +39. 0445. 6 91-5 11
Fax +41. 1. 278-29 89 Fax +39. 0445. 5 11-1 38