Professional Documents
Culture Documents
Performance
Data
The THM
Gas Turbine Range
All THM gas turbines are available Excellent part load emissions without Each THM can, as an option, be equip-
either with their standard combustion any efficiency penalty are achieved by ped with a recuperator heat exchanger
system for gaseous and liquid fuels using an patented air-bypass system; where the hot exhaust gas flow heats
(water or steam injection can be used part of the compressor air bypasses the compressor discharge air before
for NOX control) or with a Dry-Low-NoX the combustion zone and reenters entering the combustion system.
System. the process upstream of the turbine
section. This leads to a significant fuel saving.
For THM 1304 gas turbines equipped
with the Dry-Low-NOX (DLN) combus- Optimum fuel/air ratio in the lean com- Output power rating curves for the
tion system, NOX and CO emissions bustion zone is therefore possible over THM models 1203A, 1304-9, 1304-10
below 25 ppmv (dry, 15% O2) are a wide load range without the need to and 1304-11 are shown in Figures 1 to
achieved on natural gas fuel over a blow off compressor air. 4 for mechanical drive and for gener-
wide load range. ator drive applications.
All Data at 15°C (59°F), Sea Level (101.3 kPa), Rel. Humidity 60%, Zero Inlet and Exhaust Pressure Losses.
For Generator Drive: Gearbox Efficiency 98.5%, Generator Efficiency 97.5%.
THM 1203A Rating THM 1304-9 Rating
7 11
9000
14000
10
Output Power [MW]
3 6
-15 -5 5 15 25 35 45 -15 -5 5 15 25 35 45
(5) (23) (41) (59) (77) (95) (113) (5) (23) (41) (59) (77) (95) (113)
Inlet Air Temperature [°C] / [°F] Inlet Air Temperature [°C] / [°F]
Figure 1 Figure 2
Inlet Air Temperature [°C] / [°F] Inlet Air Temperature [°C] / [°F]
Figure 3 Figure 4
Sea Level (101.3 kPa), Rel. Humidity 60%, Zero Inlet and Exhaust Pressure Losses
Note: Due to the continued upgrading/uprating process of THM turbines performance data are subject to change
MAN Turbomaschinen AG MAN Turbomaschinen AG In the interests of technical progress,
GHH BORSIG GHH BORSIG this publication is subject to revision
Steinbrinkstrasse 1 Egellsstrasse 21 without notice.
46145 Oberhausen / Germany 13507 Berlin / Germany Printed in Germany.
Phone +49. 208. 6 92-01 Phone +49. 30. 43 01-03 January 2002
Fax +49. 208. 6 92-20 19 Fax +49. 30. 43 01-28 41 TURBO 922 e 0102 1,5 ba
www.manturbo.com