You are on page 1of 7

TECHNICAL PROFICIENCY

 Compilers/Editors: Microsoft Visual Studio 2008/ 2010, AVR ICC, AVR Studio v6.2, MPLAB
IDE v8.50, C30 Compiler, Source Insight, Winmerge.
 Programming Languages: Embedded C, Assembly, familiar with C++, C# concepts and VB 6.
 EDA Packages: OrCAD 9.1, Eagle 7.2 Schematic capture and PCB layout.
 Debugger/Emulators: JTAG ICE, MPLAB ICDx, REAL ICE.
 Microcontrollers: 8/16 and 32Bit Atmel: 8051, 89c55, Atmega8/128.
PIC: 16F, 18F, PIC24, dsPIC30F series and STM8/ 32 series, Low Power Management.

 Communication Protocols: I2C, SPI, MODBUS RTU/TCP, USB, IO-Link, CAN and LIN.
 Protocol Analyzer Tools: SC11 for RS-232, RS-485, and CAN Analyzer.
 HMI Software: Prizm 3.12 , DWIN DGUS for developing HMI screens.
 RTOS: Win CE6.0/ 7.0 (BSP development), .NET Framework, AtomOS
 Standard Processes: ASDP, CMMI, New Product Development, VAVE, Cost Out
 Tracking Tools: Bugzilla, TRAC, JIRA, TFS
 Version Control System: Tortoise, GIT subversion, Team Foundation

Product Development Capabilities:

1. Pressure/ Temperature/ Thermocouple/ Level Sensors:


Features:
Measuring Range: 0 – 9000 PSIG, 0 - 150°C
Output: 4 – 20mA, 0 -10V, One or Two Switch points
Accuracy: 0.5%
Display: 14 Segments
Application:
Machine Tool Industry
Factory Automation

2. Signal Conditioning Module:


Features:
Input Type: 4 – 20mA, Thermocouple, RTD
Output: 4 – 20mA, 0 -10V, MODBUS/ CAN protocol
Accuracy: 0.5%
Application:
Machine Tool Industry
Factory Automation z
3. HMI/ Display Unit:
Human Machine Interface development

4. Gateway:
 RTOS - WIN CE 7.0
 CPU: ATMEL AT91SAM9G20, 400MHz
 Flash: 256MB, NAND type
 SDRAM: 64MB
 DataFlash: 2MB
 microSD socket: up to 32GB
 Failover mechanism against system crash
 Ethernet: 1 x 10/100Mbps
 TTY: 1 x RS-232 / 422 / 485, 3 x RS-232 / 485
 USB Host: 2 x USB 2.0 compliant
 Power input: 9~48VDC, 250mA@12V
 GNU C/C++ tool chain for Linux and Windows

5. Catalyst Monitor/ Data-logger:

Easy data collection and logging

Simply connect the Data-logger unit (DLU) to target equipment to collect and log data. Realize
numerous applications, such as measuring energy consumption in buildings, remote temperature
control of facilities, monitoring operation log data of production lines.

Web Data-logger Unit advantages

A. No special software is required to configure the DLU or monitor data. Simply use the Internet

Explorer to open the setting screen (HTML file) stored on the F-ROM in the DLU.

B. There are three ways to collect data: serial communication, direct bus connection and pulse input.

The data is saved on a CF card in CSV format.


C. The CSV files can be downloaded in three different ways: via CF card (off-line), using FTP in a LAN

environment, and remote downloading using the DLU as a PPP server.


D. A timing trigger in the DLU can be set to generate CSV log files and send them as an e-mail

attachment to a computer.

1. Process data loggers and scanners

Technical data:
Accuracy : +/- 0.1 % FS, +/- 1 count.
Resolution : 0.1/1 count depends upon range.
Process sampling : 3 Channels / Second.
Inputs
Analog:
RTD like PT-100 2 or 3 wire or T/C of Type J, K, R, S, B or process inputs like 0/
4-20 mA or 0-5 VDC.
No. of inputs : 8, 16, 24, 32, 48 channel models.
Outputs
Relay:
For High / Low alarm. Optically isolated relay contact rated 230VAC @ 5a
resistive load.

Features:
 1 / 4 DIN size package
 Microprocess based accuracy.
 8 ch, 16 ch or 24 channel models
 AUTO / MANUAL mode facilities
 Addresable series interface
 USB interface with GUI for logged data download and analysis
2. Portable data loggers:
Technical Specifications
Measuring Range : 0 To 100 % RH (Humidity)
: ‐40 TO 125 Deg C (Temperature)
Accuracy @ 25 Deg C : +/‐ 1.8 % RH, +/‐ 0.2 Deg C
Electronics Operating Temp : 0 to 50 Deg C
Response : <4 Sec
Long Term Stability : Better Than 1 % RH per Year
Output : 4‐20mA, other outputs on request (0‐1/5/10Vdc)
Load Resistance : 500 ohms
Supply Voltage : 12 to 30 Vdc
Housing : ABS Plastic water tight enclosure
Protection : IP‐65
Weight : Approx 200gms
3. Portable Indicators

Technical Specifications
Measuring Range : 0 To 100 % RH
:‐25 TO +60 Deg C
Accuracy @ 25 Deg C : +/‐ 3 % RH Between 15…..85% r.H,@23 Deg C,
Electronics Operating Temp : ‐25 to 85 Deg C
Response <4 Sec
Long Term Stability :Better Than 1 % RH per Year
Output :4‐20mA, other outputs on request (0‐5Vdc.)
Load Resistance RL <300Ω
Supply Voltage : 8 to 12 Vdc
Outputs : 0-1V, 4-20mA
Housing of Electronics : ABS Plastic water tight enclosure
Protection : IP‐65
Weight of case : Approx 150gms

Features:
 3 Volt Battery Operated
 65000 Record each
 Battery life 2 Months
 Calibration facilities available
 USB interface
4. Humidity and Temperature probes
Technical Specifications
Measuring Range : 0 To 100 % RH
: ‐40 TO 190 Deg C
Accuracy @ 25 Deg C : +/‐ 3 % RH Between 15…..85% r.H,@23 Deg C,
Electronics Operating Temp : ‐25 to 85 Deg C
Response <4 Sec
Long Term Stability : Better Than 1 % RH per Year
Output : 1-5V, 2-10V, 4‐20mA
Load Resistance RL <500Ω
Supply Voltage : 8 to 12 Vdc
Housing of Electronics : ABS Plastic water tight enclosure
Protection : IP‐65
Weight of case : Approx. 200gms
Electrical connection : wired leads with 1 Mtr Cable
Housing of Sensor : SS Tube with Sintered Bronze Filter