You are on page 1of 6

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx FTZU 12.0023X Issue No: 3 Certificate history:


Issue No. 3 (2017-10-30)
Status: Current Issue No. 2 (2016-01-27)
Page 1 of 4 Issue No. 1 (2015-03-10)
Date of Issue: 2017-10-30 Issue No. 0 (2012-12-21)

Applicant: KROHNE Altometer


Kerkeplaat 12
3313 LC Dordrecht
The Netherlands

Equipment: Signal Converter IFC 300F


Optional accessory:

Type of Protection: Flameproof enclosure, increased safety, intrinsic safety, dust protection

Marking:
Ex db e [ia] IIC T6 Gb
Ex db e [ia Ga] IIC T6 Gb
Ex tb IIIC T 85°C Db

Approved for issue on behalf of the IECEx Dipl. Ing. Lukáš Martinák
Certification Body:

Position: Head of the Certification Body

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


Fyzikalne technicky zkusebni ustav
(Physical -Technical Testing Institute)
Pikartska 7, 71607 Ostrava - Radvanice
Czech Republic
IECEx Certificate
of Conformity
Certificate No: IECEx FTZU 12.0023X Issue No: 3

Date of Issue: 2017-10-30


Page 2 of 4

Manufacturer: KROHNE Altometer


Kerkeplaat 12
3313 LC Dordrecht
The Netherlands

Additional Manufacturing location(s):


Krohne Measurement Technology (Shanghai) Co., Ltd.
No. 555 Min Shen Road, Songjiang Industrial Area
Shanghai 201612
China

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards:

IEC 60079-0 : 2011 Explosive atmospheres - Part 0: General requirements


Edition:6.0
IEC 60079-1 : 2014-06 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:7.0
IEC 60079-11 : 2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0
IEC 60079-31 : 2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2
IEC 60079-7 : 2006-07 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:4

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

CZ/FTZU/ExTR12.0023/00 CZ/FTZU/ExTR12.0023/01 CZ/FTZU/ExTR12.0023/02


CZ/FTZU/ExTR12.0023/03

Quality Assessment Report:

NL/DEK/QAR11.0057/04 NL/DEK/QAR12.0071/03
IECEx Certificate
of Conformity
Certificate No: IECEx FTZU 12.0023X Issue No: 3

Date of Issue: 2017-10-30


Page 3 of 4

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

A type IFC 300 F signal converter is intended for feeding the coil circuit of an electromagnetic flow meters and for amplifying and
processing the voltage induced over the electrodes of electromagnetic flow meters.
A type MH300-Ex body housing of casted aluminium or stainless steel is separately certified in type of Ex-protection „Ex d e [ia] IIC”
and can be screwed on an L-shapped support or bracket of casted aluminium or casted stainless steel. In the body housing is situated
connection box equipped with terminal in type of Ex-protection „Ex e II“ and line-bushing in type of Ex-protection „Ex d II“. Within
housing is situated electronic unit type IFC 300 in type of Ex-protection “[Ex ia] IIC”.  Within L-shapped support or bracket is situated
terminal for intrinsically safe circuits and terminal in type of Ex-protection “Ex e II“ for connection of flow meter. Terminals are soldered
on the PCB. All entries are provided by cable glands in type of Ex-protection “Ex e II”. Body housing area and L-shapped
support/bracket area are separated by flameproof cable feed- through in type of Ex-protection “Ex d e IIC”.

SPECIFIC CONDITIONS OF USE: YES as shown below:

1) Tamb: -40°C to +65°C

2) For information on the dimensions of the flameproof joints the manufacturer shall be contacted.

3) The fasteners for the primary head shall be property class A2-70 or A4-70.

4) To avoid the risk of ignition as a result of electrostatic charging, the IFC300F housing can not be used in locations in which:
- High charge generating processes,
- Mechanical friction and separation processes,
- Electron emission (e.g. near electrostatic coating equipment) may occur.
IECEx Certificate
of Conformity
Certificate No: IECEx FTZU 12.0023X Issue No: 3

Date of Issue: 2017-10-30


Page 4 of 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Issue 1:
The recognition of the additional manufacturing location.

Issue 2:
Upgrade to the latest editions of standards.
The conditions for certification have been updated.
The marking has been modified.

Issue 3:
The electrical parameters were completed in the Annex to this CoC.
A revision of the documentation list has been carried out.
The marking has been revised. 

Annex:

Annex_to_Certificate_IECEx_FTZU_12_0023_Issue_No_3.pdf
Annex
to Certificate IECEx FTZU 12.0023 Issue No.3
Date: 30.10.2017

Manufacturer: KROHNE Altometer


Address: Kerkeplaat 12; 3313 LC Dordrecht, The Netherlands
Product: Signal Converter type IFC 300 F

Technical parameters:

Power supply, 100-230 V ac, -15/+10%, 50--60 Hz, 22 VA or


terminals L, N or L+, L-, 12-24 V dc, -10/+30%, 12 W or
in type of protection 24 V ac/dc, ac : -15/+10%, 50-60 Hz, 22 VA
increased safety “e” dc : -25/+30%, 12 W
Um = 253 V for all versions

Inputs/Outputs,
terminals A, A-, A+, B, B-, C, C-, D, D-
in type of protection increased safety “e”
PCB name Electrical data
Basic IO, Un ≤ 32 V, In ≤ 100 mA
Modular IO with or without Um = 253 V
Modular Carrier+IO Modules
Fieldbus IO (Profibus PA or FF)
Profibus DP IO
modbus IO

Inputs/Outputs,
terminals A, A-, B, B-, C, C-, D, D-
in type of protection intrinsic safety “i”
PCB name Electrical data
Ex i IO, Current output active with HART Ex ia IIC
Ex i Option,Current output active Uo = 21 V, Io = 90 mA, Po = 0,5 W
Linear characteristic
Co = 90 nF / 110 nF, Lo = 2,0 mH / 0,5 mH
Ex i IO, Current output passive with HART Ex ia IIC
Ex i Option Current output passive Ui = 30 V, Ii = 100 mA, Pi = 1,0 W
Ci =10 nF, Li ≈ 0 mH
Ex i IO, Pulse/Status output, passive Ex ia IIC
Ex i Option & Ex i Option 2 Ui = 30 V, Ii = 100 mA, Pi = 1,0 W
Pulse/Status output, passive or Control input, Ci =10 nF, Li ≈ 0 mH
passive
Fieldbus IO ( Profibus PA or FF) Ex ia IIC
Fisco field device Ui = 24 V, Ii = 380 mA, Pi = 5,32 W
Ci ≈ 5 nF , Li = 10 µH
Ex i Option 2 Ex ia IIC
Current input, passive Ui = 30 V, Ii = 100 mA, Pi = 1,0 W
Ci =10 nF, Li = 0 mH

Ex i Option 2 Ex ia IIC
Current input, active U0 = 24,1 V, I0 = 99 mA, P0 = 0,6 W
Linear characteristic
C0 =75 nF , L0 = 0,5 mH

Page: 1/2

FTZÚ s.p., Pikartská 1337/7, 716 07 Ostrava Radvanice, Czech Republic


tel +420 595 223 111, fax +420 596 232 672, e-mail: ftzu@ftzu.cz
Annex
to Certificate IECEx FTZU 12.0023 Issue No.3
Date: 30.10.2017

Electrode circuit : in type of equipment protection Ex ia IIC,


(terminals 1,2,20,3,30,4,40) Uo = 14 V, Io = 70 mA, Po = 300 mW,
Linear characteristic
Co = 430 nF, Lo = 2 mH

The intrinsically safe Inputs/Outputs circuits and the intrinsically safe electrode circuit are safely
electrically isolated from all other circuits to a peak value of the nominal voltage of 375 V.

Field coil circuit In type of equipment protection Ex e IIC


(terminals 7,8,9) Un <= 40V
In <= 125 mA
Internal fusing ≤ 160 mA
Maximum prospective short circuit current
Ik = 35A

Page: 2/2

FTZÚ s.p., Pikartská 1337/7, 716 07 Ostrava Radvanice, Czech Republic


tel +420 595 223 111, fax +420 596 232 672, e-mail: ftzu@ftzu.cz