Professional Documents
Culture Documents
5. Specificcatiasaas of DM Plant :
DM Plant shall consists of Cation Column, Anion Column followed by Mixed bed.
9 Specifications of Cation Column
J Ind~~strial MS Rubber Lined (Food grade) Cation column.
J One no. MSRL Pressure Vessel (600 m m 0, 1500 m m HOS)
J One no. ejector for sucking of the Hydrochloric Acid plus one spare ejector
J One set of Frontal Piping,
a. Cation Cslaamltn
J -
Vessel MOC : MS Rubber Lined.(Food grade)
Q Diameter -mm : 600
& Height on Straight-mm ' : 1500
J Type ofResin : Strong acid cation (INDION - 225H)
Q Quantity of Resin : 400 Liters
r;lB Regenerant Chemical : HC1 (Hydrochloric Acid-33%) -1 00 ltr
\
> Specificatiopls of DIM Water Storage Tank
J Type ofltank : MS rubber lined
J Mounting : Horizontal
J Capacity . :25,000 ltrs
J Diameter of the tank : 2.5 mtrs approx.
J Length of the tank : 4.75 mtrs approx.
J MOC : Mild Steel
J Rubber lining material : Chloroprene Rubber (Food grade)
J Thickness of Tank : 6.0 + 0.2mm
J Thickness of Rubber lining . : 3mm
J Shape of tank : Cylindrical
J Level p a g e : to be fitted as shown in figure
J Chloroprene rubber (food grade) based composition with the following properties
shall be used for lining
J Pipeline plumbing works, Old equipment removal and new-equipment Erection &
/
i
I
* *d-f Scientist .
{!
I
6
The installation and commissioning of the DM Plant & DM.Water storage tank are
within the scope of vendor and should be done under the guidance of user DRDL as per the
specifications.
11. Acceptance criteria : -
a) Physical Inspection
9 Physical inspection against any leakages
b) The water should have the following properties after treating in the plant like
9 Total hardness < 3ppm
9 Chloride content < lppm
9 pH value in the range 6.8 - 7.2
> Conductivity < 6 ymhos/cm
12. Cerdificates :
a) Calibration certificate fiom manufacturer of rota meter
b) Test report from manufacturer for any defects in tank material
c ) Test report for the rubber lining as per specification
13. Warranty :
One year warranty from the date of installation and commissioning of the DM Water
Plant & DM Water storage tank against any manufacturing/ fabrication defects, leakages etc.
4
I Scientist 'E' *
h
Reliability h ~ u a l i ~ ~ s s u n n c s
DRDL, Wyderabad-500 068