You are on page 1of 2

Service Information

Document Title: Function Group: Information Type: Date:


Wiring diagram 8 – Fan 370 Service Information 09/06/2017
ECU
Profile:
G740B Volvo

Wiring diagram 8 – Fan ECU


Showing Selected Profile

Valid for serial numbers


Model Production site Serial number start Serial number stop
G740B Volvo

No. Part Description Std./ Specification Location


designation Opt.
1 FU15 Turn signal/ Std. 10 A Fuse panel, convenience
Horn center
2 SE2604 Charge air Std. Operating temperature range: Charge air cooler outlet
temperature fan 50º– 125ºC (122 – 257ºF)
control sensor Resistance: 811 to 77 ohms
3 SE2603 Water coolant Std. Temperature Resistance Intake to radiator
temperature fan 25ºC (77ºF) – 2252 ohms 5%
control sensor 50ºC (122ºF) – 811 ohms 5%
80ºC (176ºF) – 283 ohms 5%
100ºC (212ºF) – 153 ohms 5%
125ºC (257ºF) – 77 ohms 5%
4 SE2605 Hydraulic oil Std. Temperature Resistance Hydraulic tank, lower front,
temperature fan 25ºC (77ºF) – 2252 ohms 5% left-hand side
control sensor 50ºC (122ºF) – 811 ohms 5%
80ºC (176ºF) – 283 ohms 5%
100ºC (212ºF) – 153 ohms 5%
125ºC (257ºF) – 77 ohms 5%
5 MA2601 Fan control Std. Minimum current = 0.15 A at Below frame in front of
valve solenoid 500 rpm hydraulic tank, right-hand
Maximum current = 0.85 A at side
1750 rpm
6 Fan ECU Fan electronic Std. Below radiator enclosure,
control unit left-hand side in front of
fan
Figure 1

Wiring diagram 8 – Fan ECU

Figure 2

You might also like