.".,tfl#
F
To,
The Project Manager,
IRB West Coast Tollway Pvt. Ltd.,
Kadikodi Village,
Kumta.
Sub:- Four Laning of Goa/Ifurnataka border Kundapur section of NH-17 (Now NH 66) from
-
km.93-700 to km.283.300 in the state of Karnataka under NHDp phase IV on design build
Operate Transfer (DBFOT) toll basis: Source approval for Reinfocement steel from lWs
Monnet Ispat& enery Limited- reg.
Dear Sir,
With referancg to the above subject matter,our representative visited the factory IWs Monnet
Ispat & Enery Ltd Raigarh,Chattisgarh on l5.O4.2Ol5,lWi Monnet Ispat & Enery Ltd fulfills all the
requirements and giudelines of MoRTH as well as steel circular as a primary producer.The
firm has put
up- Integrated steel plant at Raigarh,Chattisgarh with production prociss p"r the gudelines issued by
Ministry of Steel. ^
A1 the factory pr"-Tiryr- physical and
ryndom sampling from the lot produced were tested for
chemical proerties as per IS 1786 and all the results found satisfactory.
In view of theatove, you may procure TMT steel from IWs Monnet Ispat & Energy Limited and
advised to strictly check the following
l.Every consignment shall be supported with MTC
2.Every Lot shall be tested in approved lab in accordance with IS 17g6
3.Only fresh steel shall be delivered at site.
With Regards,
ffi
For AECOM Asia Company ltd. In Association with
Rodic Consultants
(1
(Kiran S.Vishwaroop)
Team Leader
%#,
Encl: Joint Inspection Report.
&
f-,s{}._:.r"}:r
Monnet lspat & Energy Limited.
Village & P.O. : Naharpalli, Tehsil. : Kharsia, Raigarh-496661{Chhattisgarh},
5l.No. Clause
Parameter Tested 5pecified Valui Observed Value
Ref"
Chemlcal Comoosltion
*_*&
lc% iio.zs {nnax.) 0.195
ii) s% ii)0.0t10 (Max.) 0.029
7 iiilP% 4.2 iii) 0.0a0 (Max,) 0.o19
tlu!S%+P% iv)0.075 (Max,l 0.o4.8
VlMn% 0.65
vrl cE Vl)0.42 (Max! 0.30
2 Freedom from defects 4.3 As per clause Cl - 4.3 Satisfactory
1. Mr.Viiay B Madankar,
1. Mr.Anup o", ft*
q.ffir
(sr.Manager, oiun)
( Manager,lRB West Coast
2.Mr.AnirNadagouda *t{rlf
ilY,':iXjJi'-"i*tf4
(sr.QME, AEcoMRoDlcrv)\41 Yl ' 3. Mr.Amardeen Srirastau&F
(D.M.-Sales)
-
Machine Model .fensile Test Report
: TUE -C- IOOO
lvlachine Serial No, Test File Name : H-4o34 {KKBOT).Utm
t 2OL2 I 90
Customer Name Date : l5/04/ZA!,S
: I(KBOT PROTECT, KARNATATA
STATE Customer Address !
Test Type
: Tensile
Heat Number Order No.
: BO4aBO
fnput Data
Specimen Shape Output Data
r Sotid Round (TMT)
O.2olo prooF Load
Specimen Description :454.2
: Size: 32rnm, Grade:FE_S0OD kN
0,2olo proof Stress
:566.277 N,/mma
Initial Gauge Lengfi Tensile Load
: 16O : 546.2OO kN
mm Tensile Strenglh
Cross Section Area :681.O98 N/mmz
:8O1.94 mm2 o/o
Final Gauge Length Elcngation
: 193.6 ; 21,O0 ah
tnm
Load Vs Extension
z
-s
,E
o
CH I {n:nr}
t.",..*...:
Monnet lspat & Energy Limited.
Village&P.O.:Naharp alli, Tehsil. : Kharsia, Raigarh-496661 {Chhattisgarh}.
Heat No. l
Sl.No. Clause
Parameter Tested Specified Value observed*alue
Ref.
Chemical Composition
ilc% i) 0.25 {Max,) 0.194
aits% iiI0.040 (Max.) 0.018
7. iii)P% 4.2 iii) 0.040 {Max.} 0.019
ivlS0A+P% iv) 0.075 (Max,) 0.037
VlMn% 0.58
vrl cr u| o.a2 {Max} 0.31
2 Freedom from defects 4.3 As per clause Cl - 4,3 Satisfactory
3 Yield Stress/0.Z% Proof Stress {N/mm2} 9.2 Min.500.0 558
*. fvlr,*nup Sa*
1. Mr.Vijay B Madankar
( Manager,lRB West Coast
2. Mr.Anir*"orrororW#ft/,.,' t t
{Sr.QME, AEcoM RoDtcrv} \ 6\d4'\ I 3. Mr.Amardeep sravastav
(D.M.-Sales) {fr.,1.**
;:--r
(For KKBOT Project, Karnataka state) (for MIEL Representative)
fremarks: one Sample selected randomly of slze 25mm for chemical analysis.
Beports are as follows :
C%= 0-1935, S% =0.O2O1, P = 0.0ll2,Mn = 0.6903, CE =0.31;
]\
&r {} &45;
I fri,?ffi
E*nail
:,ti,r,*:rt_f
Phone : 07i62.X7iio'e,
g:, o+ !fi
nrislrgh@nronnetgroup
fu*'[?,{,,ijrjtfi
il?rAi"rruSO.., ;
.on, W*t
f ,.,,,,,,,ssarh;
.iL
rtI762-I91510
r,r,(,r.* r.r.lcr.lr.retqrcup
conl
Test Type
: Tensllc
Heat Number Order No"
*805011
rnputData %-'
Specimen Shape
r''Sotid Round (TMT)
Output Data
Specimen Description 0.2Yo proof Load
: Size: 2omm, Grade:FE_sOOD : l73.ZS KN
0.2olo Proof Stress
: 558.83S N/mm2
Initial Gauge Length Tensile Load
: lOO : 2Ol.lOO KN
mm Tensile Strength
Cross Section Area ; 648.668
:3lO.O2 mm2 N/mrn2
Final Gauge Length Vo Elongation
: 119 ; 19.00 olo
mm
Load Vs Extension
CH f {nrrn)