You are on page 1of 184

TABLE OF CONTENTS

FLOOR DECK CATALOG

COMPOSITE DECK
AND NON-COMPOSITE DECK
FOR FLOOR AND ROOF DECK APPLICATIONS

VERSION 1.0
TABLE OF CONTENTS

General Benefits
of Composite Steel Deck
ASC Steel Deck has a firm understanding of the benefits
composite steel deck provides in building construction.
The strength of composite steel deck slab, relative to its
light weight, makes it the clear building material of choice
when compared to the alternative cast-in-place concrete
approach. Composite steel deck serves a dual function
as it provides both concrete reinforcement and a concrete
form, while serving as a working platform through the
erection process. Moreover, projects designed with
a composite deck system simply go up faster. The
versatility, recyclable content, structural performance, and
ease of installation makes steel deck the ideal building
material for building owners, architects, and engineers.

Aesthetic Value of Steel Deck


ASC Steel Deck products offer the beauty of exposed steel as an added benefit to the structural performance required of
building designs. Our new Smooth Series™ cellular deck offers a blemish free beam-to-pan rivet attachment, providing a
clean surface ideal for an exposed steel design. When noise reduction is a necessity, ASC Steel Deck's Acustadek® panels
offer acoustical noise reduction capabilities with aesthetic features which complement its use on exposed applications.
Acustadek® is generally preferred in high noise areas such as airports, schools, gymnasiums, and concert halls.

Offering a Full Line of Steel Deck Products


ASC Steel Deck is the only steel deck manufacturer on the West Coast which offers a full line of light-gage structural and deep
deck products. From the standard 1½” to 3” roof and composite floor deck, to concrete form deck, to long spanning deep
deck profiles, ASC Steel Deck’s extensive product offer meets the needs of the most complex conditions and demands for
structural performance and design. Most of our floor and roof deck products are offered in a variety of perforated acoustical
options. For structural and acoustical performance information on these products, refer to the Acustadek® section of this
catalog and our Roof Deck Catalog.
TABLE OF CONTENTS

Table of Contents

GENERAL INFORMATION
Your Feedback is Welcome
ASC Steel Deck is leading the way in innovation with Leading the way in steel deck innovation is dependent
ongoing testing of our profiles. As a result, our printed upon your feedback. We invite architects, engineers,
catalogs may not contain/reflect the latest test results building owners, and all members of the building design
and values of our products. For the most current load and construction industry to reach out to ASC Steel Deck

3W PANELS
tables, refer to our catalog online at www.ascsd.com. with any comments, suggestions, or needs for a profile
we currently do not offer

Email us at info@ascsd.com

2W PANELS
1.0 GENERAL INFORMATION 5.0 N PANELS
1.1 Panel Features and Benefits . . . . . . . . . . . . . . . . . . . . . . 2-5 5.1 NH-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 124
1.2 Product Offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 5.2 NHF-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 125
1.3 Product Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5.3 NHF-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 126-127
1.4 Fire Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-21 5.4 NH-32 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 128-138
1.5 Steel Deck Section Properties . . . . . . . . . . . . . . . . . . . 22-23
1.6 Web Crippling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25 6.0 C PANELS (FORM DECK - CF7⁄8 and CF13⁄8)
1.7 Steel Deck at Concrete Form . . . . . . . . . . . . . . . . . . . . 26-27 6.1 C0.9-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 140
1.8 Composite Deck-Slab Design . . . . . . . . . . . . . . . . . . . 28-30 6.2 C0.9-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 141
1.9 Non-Composite Deck-Slab Design . . . . . . . . . . . . . . . . . 31

B PANELS
6.3 C0.9-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 142-143
1.10 Penetrations and Openings . . . . . . . . . . . . . . . . . . . . . 32-35
1.11 Composite and Non-Composite 6.4 C1.4-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 144
Diaphragm Shear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.5 C1.4-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 145
1.12 Composite Deck-Slab Tables . . . . . . . . . . . . . . . . . . . 38-39 6.6 C1.4-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 146-147
1.13 Support Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-45
1.14 Side Seam Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47 7.0 D PANELS (FORM DECK)
1.15 Edge Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49 7.1 4.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 148
1.16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 7.2 4.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 149
1.17 Typical Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51-54 7.3 4.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 150-151

N PANELS
1.18 Composite Deck-Slab 7.4 4.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 152
Tables General Requirements . . . . . . . . . . . . . . . . . . . 55-57 7.5 4.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 153-155
7.6 4.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 156-157
2.0 3Wx PANELS
2.1 3WxH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 58 7.7 6D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 158
2.2 3WxHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 59 7.8 6D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
2.3 3WxHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 60-61 7.9 6D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . . 160-161
2.4 3WxH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 62-81
7.10 6DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 162
3.0 2W PANELS

C PANELS
7.11 6DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . 163-165
3.1 2WH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 82 7.12 6DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 166-167
3.2 2WHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 83
3.3 2WHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 84-85 7.13 7.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 168
3.4 2WH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 86-107 7.14 7.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 169
7.15 7.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 170-171
4.0 B PANELS
4.1 BH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 108 7.16 7.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 172
4.2 BHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 109 7.17 7.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 173-175
4.3 BHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 110-112 7.18 7.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 176-177
D PANEL

4.4 BH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 113-122


8.0 ACUSTADEK®
8.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
8.2 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179

METRIC CONVERSION CHART . . . . . . . . . . . . . . . . . 180


ACUSTADEK®

Hilti is a registered trademark of Hilti Corp., LI- 9494 Schaan, Principality of Liechtenstein
PNEUTEK is a registered trademark of Pneutek, 17 Friars Drive Hudson, NH

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 1


TABLE OF CONTENTS

1.1 Panel Features and Benefits

3WxH-36 Hi Form® 3WxHF-36 Hi Form®

Composite deck Composite deck


3 inch deep, 36 inch coverage, 3 inch deep, 36 inch coverage,
10 foot to 14 foot Optimal Span Range 11 foot to 15 foot Optimal Span Range
®
No Acustadek Options Pan Perforated Acustadek® Option (Available with
Smooth Series™ rivet attachments or welded)
 Proven for 10 to 14 foot span conditions
 Aesthetic flat pan underside
 Meets SDI 3x12 inch standard profile requirements
 Meets SDI 3x12 inch standard profile requirements
 Longer unshored spans than 2WH-36 and BH-36
 Meets industry standard 4.5” min. flute width  Longer unshored spans than 2WH-36 and BH-36
 Meets industry standard 4.5” min. flute width
 Compatible with all standard concrete anchors
 Compatible with all standard concrete anchors

2WH-36 Hi Form® 2WHF-36 Hi Form®

Composite deck Composite deck


2 inch nominal depth, 36 inch coverage 2 inch nominal depth, 36 inch coverage
7 foot to 12 foot Optimal Span Range 9 foot to 13 foot Optimal Span Range
®
No Acustadek Option Pan Perforated Acustadek® Option (Available with
Smooth Series™ rivet attachments or welded)
 Least steel weight per square foot floor deck
 Aesthetic flat pan underside
 Meets SDI 2x12 inch standard profile requirements
 Meets SDI 2x12 inch standard profile requirements
 Reduced composite slab depth compared to
3WxH-36 and NH-32  Reduced composite slab depth compared to
3WxHF-36 and NHF-32

BH-36 Hi Form® BHF-36 Hi Form®

Composite deck Composite deck


1 ⁄2 inch depth, 36 inch coverage
1
11⁄2 inch depth, 36 inch coverage
7 foot to 10 foot Optimal Span Range 7 foot to 12 foot Optimal Span Range
No Acustadek® Option Pan Perforated Acustadek® Option (Available with
Smooth Series™ rivet attachments or welded)
 Lowest composite deck-slab weight per square foot for
the specified concrete thickness above the deck  Aesthetic flat pan underside
 Meets SDI 1.5WR (wide rib) standard profile  Meets SDI 1.5WR standard profile requirements
requirements

2 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Panel Features and Benefits 1.1

GENERAL INFORMATION
NH-32 Hi Form® NHF-32 Hi Form®

3W PANELS
Composite deck Composite deck
3 inch depth, 32 inch coverage 3 inch depth, 32 inch coverage
10 foot to 15 foot Optimal Span Range 11 foot to 15 foot Optimal Span Range
®
No Acustadek Options Pan Perforated Acustadek® Option (Available with
Smooth Series™ rivet attachments or welded)
 Longest unshored spans

2W PANELS
 Aesthetic flat pan underside
 Excellent alternate to SDI DR (deep rib) profile
 Excellent alternate to SDI DR (deep rib) profile
 Lower composite deck-slab weight than 3WxH-36 for
the specified concrete thickness  8 inch on center low flute spacing to allow for bearing
wall studs to be at 16 inches on center
 8 inch on center low flute spacing to allow for bearing
wall studs to be at 16 inches on center

B PANELS
C0.9-32 (CF7⁄8) C1.4-32 (CF13⁄8)

N PANELS
Non-composite deck Non-composite deck
⁄8 inch depth, 32 inch coverage
7
13⁄8 inch depth, 32 inch coverage
2 foot to 7 foot Span Range 4 foot to 9 foot Span Range
No Acustadek® Options No Acustadek® Options
 Good for short span conditions  Good for intermediate span conditions
 For use when metal deck is used as a leave in place  For use when metal deck is used as a leave in place

C PANELS
form form

D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 3


TABLE OF CONTENTS

1.1 Panel Features and Benefits

4.5D-12 4.5DF-24

Non-composite deck Non-composite deck


4 ⁄2 inch depth, 12 inch coverage
1
41⁄2 inch depth, 24 inch coverage
12 foot to 21 foot Span Range 15 foot to 21 foot Span Range
®
No Acustadek Option Pan Perforated Acustadek® Option
 Allows for longest unshored spans  Aesthetic flat pan underside
 For use when metal deck is used as a leave in place form  Allows for longer unshored span when metal deck is used
as a leave in place form
 Longer unshored span than non-cellular profile
 For use when metal deck is used as a leave in place form

6D-12 6DF-24

Non-composite deck Non-composite deck


6 inch depth, 12 inch coverage 6 inch depth, 24 inch coverage
14 foot to 25 foot Span Range 15 foot to 25 foot Span Range
No Acustadek® Option Pan Perforated Acustadek® Option
 Allows for longest unshored spans  Aesthetic flat pan underside
 For use when metal deck is used as a leave in place form  Allows for longer unshored span when metal deck is used
as a leave in place form
 Longer unshored span than non-cellular profile
 For use when metal deck is used as a leave in place form

7.5D-12 7.5DF-24

Non-composite deck Non-composite deck


7 ⁄2 inch depth, 12 inch coverage
1
71⁄2 inch depth, 24 inch coverage
16 foot to 26 foot Span Range 16 foot to 27 foot Span Range
®
No Acustadek Option Pan Perforated Acustadek® Option
 Allows for longest unshored spans  Aesthetic flat pan underside
 For use when metal deck is used as a leave in place form  Allows for longer unshored span when metal deck is used
as a leave in place form
 Longer unshored span than non-cellular profile
 For use when metal deck is used as a leave in place form

4 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Panel Features and Benefits 1.1

GENERAL INFORMATION
Economical Selection Guide based on Recommended Unshored Spans

Product 2 4 6 8 10 12 14 16 18 20 22 24 26 28

3W PANELS
C0.9-32

C1.4-32

BH-36

2W PANELS
2WH-36

3WxH-36

NH-32

BHF-36

B PANELS
2WHF-36

3WxHF-36

NHF-32

N PANELS
4.5D-12

6D-12

7.5D-12

C PANELS
4.5DF-24

6DF-24

7.5DF-24
D PANEL

Box outlines the range of unshored spans from the recommended unshored span range

Gray cells are based on 1 hour and 2 hour fire ratings with 20 and 18 gauge decks
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 5


TABLE OF CONTENTS

1.2 Product Offer

ASC Steel Deck offers a robust selection of products. Galvanized


Our lightweight composite and non composite steel deck ASC Steel Deck offers steel deck products that are
profiles have depths that range from 7⁄8” to 71⁄2”. Panel galvanized in accordance with ASTM A653. The standard
lengths range from 3’-6” to 45’. Steel deck panels are galvanized coating is G60 (0.6 ounce per square foot).
supplied with both galvanized and painted finishes to G-90 (0.9 ounce per square foot) is recommended
meet an array of project finish requirements. for high humidity and corrosive conditions. G-40 (0.4
ounce per square foot) may also be specified for greater
Product Description economy. Heavier galvanized finishes than G-90 can be
To assist designers with specifying the correct steel deck specified for more severe environmental conditions and
profile, see figure 1.2.3 which details how to specify the exposures. Inquire for product availability and minimum
intended product. Following these guidelines will help order sizes for G-40 or galvanizing heavier than G-90.
to eliminate requests for information and change orders
due to insufficient product descriptions in the plans and All ASC Steel Deck galvanized decks are manufactured
specifications. Designers can be assured that the product from chemically treated steel coil in accordance with
delivered is the product intended. Simply specify the gage, ASTM A653. Chemical treatment is often referred to
panel profile, panel coverage, metallic/paint coating, and any as passivation. The chemical treatment protects the
modifiers appropriate for the desired product. galvanized steel from developing white rust during
storage and transport of both coil and finished product.
Deck Panel Lengths Some field-applied paint systems may not be compatible
All ASC Steel Deck products are manufactured to the with the chemical treatment. The paint manufacture
specified length for the project. The following table should be consulted to determine how the deck should
summarizes the minimum and maximum lengths which can be prepared prior to painting. ASC Steel Deck is not
be manufactured for each profile. responsible for the adhesion of field applied primers and
paints.
Figure 1.2.1: MANUFACTURED PANEL LENGTHS
Profile Factory Cut Length Galvanized with Prime Paint
Minimum Maximum ASC Steel Deck offers all of its standard galvanized
Non- BH-36, NH-32, 2WH-36, 3WxH-36 3’-6” 45’-0” options with factory applied prime paint on the underside
cellular of the deck. The prime paint is available in standard gray.
C0.9-32 & C1.4-32 4’-0” 45’-0”
White primer is also available. The standard 0.3mil water-
4.5D-12, 6D-12, 7.5D-12 6’-0” 32’-0” based gray acrylic primer has been specially developed
Cellular BHF-36, NHF-32, 2WHF-36, 3WxHF-36 5’-0” 40’-0” to provide superior adhesion to the galvanized steel deck
4.5DF-24, 6DF-24, 7.5DF-24 6’-0” 32’-0” and is suitable for use in many UL fire rated assemblies.
Factory applied primer is an impermanent interim coating
Tolerances that is intended to have finish paint applied after the deck
ASC Steel Deck manufactures to industry standard tolerances. is installed. The galvanized with prime paint option may
The tolerances are summarized as follows. eliminate the need for any special surface preparation
for field applied paint applications which is often a
Figure 1.2.2: PANEL TOLERANCES
requirement for chemically treated bare galvanized steel
Length ±1/2” deck panels. ASC Steel Deck is not responsible for the
Coverage Width -3/8” +3/4” adhesion of paint systems applied in the field.
Sweep 1/4” in 10’ length
Cellular deck is offered with a galvanized steel pan or a
Square 1/8” per foot width
prime paint over galvanized steel pan. This 0.3mil gray
Height ±1/16” primer is applied to the underside of the pan prior to
resistance welding or riveting the cellular deck beam to the
pan. Our new Smooth Series™ rivet attachment is flush with
Finish Options
the exposed bottom surface, omitting visible “bumps” and
ASC Steel Deck offers several finish options that are
burn marks, eliminating the cost of touch-ups associated
appropriate for a variety of applications. Our standard G60
with resistance welded deck products. Resistance welded
galvanized finish is suitable for most applications, offering
deck, the current industry standard, leaves burn marks on
excellent corrosion protection and compatibility with fire
the pan which generally require cleaning and touch-up prior
proofing when used in UL fire rated assemblies. We also offer
to the application of a finish paint system being applied.
Prime Shield®, an economical prime paint system over bare
Touching up the burn marks is generally much more cost
cold rolled steel. Prime Shield® offers the steel limited interim
effective than preparing an unpainted, chemically treated
protection from rusting during transport and erection before
surface for the application of a field primer. The prime
the concrete topping is applied. Prime Shield® should not be
painted galvanized pan provides a good substrate for the
used in high humidity or corrosive environments. Prime paint
application of most field-applied paint systems. ASC Steel
over galvanized steel deck can also be specified to obtain the
Deck is not responsible for the adhesion of paint systems
benefit of the corrosion protection of galvanized steel deck
applied in the field.
with a factory applied prime paint substrate.
6 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

Product Offer 1.2

GENERAL INFORMATION
Figure 1.2.3: PRODUCT OFFER DESCRIPTION

r
fie

s
s)
er

in
di
er

er
t
ge

g(
r

ain
fi

pa
Mo
fie
fi

fi
di
e

in
ra
di

di
)

de
Mo
di
(s

ofi

at
ve
Mo

Mo
n

de
Mo
ge

Si
Co
tio
Pr

Co

l
na

Si
Ga

ip

ial
m
ra
rm
l

ic
ne
Gr

tio

tto
p

ec
gu

ne

ll

To
Fo
Pa

ta
lta

Op

Sp
Bo
nfi

Pa

Me
Hi
De

Co
18/20 DG B H F _ 36 A G60/G60 Gray / Gray

3W PANELS
Specify See Omit: Bare Non- None: No primer Omit: None
Required Deck Galvanized Steel
Omit: Standard
Gage(s) of Profiles and Prime Shield®: Gray primer on NS: No Swage,
profiles without
Deck Coverage G60: Galvanized bare steel or GO1 galvanized B-36 only
See Acustadek®
List
Deck perforations
G90: Galvanized Gray: Primer over galvanized
22 Profiles and
(Available for cellular deck)
Coverage AW: Acustadek®
G60/G60: Galvanized
211 Omit: Standard Omit: Non- List web perforation
Weldable Primer: (Only available
standing seam embossed for use with non-
G90/G90: Galvanized for cellular decks span underside
202 side lap interlock smooth deck cellular standard
Omit: Standard only)
or DeltaGrip, DG, Note: Inquire for other

2W PANELS
(Roof)
191 profiles non-cellular profiles only galvanized coating weights
DG: DeltaGrip H: Embossed White: Primer over galvanized
with standard
standing seam HiForm
182 standing seam AT: Acustadek®
side lap interlock composite
deck (Floor)
side lap interlock total perforation Cellular Deck
for use with non-
162
F: Cellular (Welded) cellular standard
Cellular deck is a good choice when a flat appearance
142 or DeltaGrip, DG, on the underside of steel deck is desired. Cellular deck is
Fr: Cellular (Smooth profiles only
Series™ Rivet manufactured from a top fluted section of steel deck referred
20/203
Attachment) A: Acustadek® to as the beam and a flat bottom section referred to as the
pan perforation
20/183
N: Nestable side lap, for use with
pan. The male and female side seam interlock is formed on
20/163 (B and N Deck only) cellular profile the edges of the pan.

B PANELS
modifier, F, only
18/203 S: Standing seam
screwable side lap V: Venting
18/183 (2WHS-36 only) (non-cellular only)

18/163 DECK PROFILE


AND COVERAGE LIST
16/20 Non-Composite Roof Coverage
B 36 inches
16/18 3
N 32 inches
Not Applicable
16/163 2W 36 inches

N PANELS
3Wx 36 inches
1
2W & 3Wx only on special order
C0.9-32 Not Applicable 32 inches
2
D is only available in these gages C1.4-32 CP-32 32 inches
4.5D 12 inches Figure 1.2.4: WELDED ATTACHMENT
3
DF is only available in these gages 4.5DF 24 inches (Pictured from topside)
6D 12 inches
Not Applicable
6DF 24 inches The welded method offers resistance welds in accordance
7.5D 12 inches with UL 209. There is one row of resistance welds in each
7.5DF 24 inches
low flute of the beam.

C PANELS
Prime Shield®
Prime Shield® is prime painted cold-rolled, ASTM 10081,
steel deck. The standard gray primer is applied to the
underside of the steel deck (as compared to both sides for
roof deck) leaving the top side bare for concrete adhesion.
The formation of light rust on the top side of the deck prior
to concrete placement is common and does not adversely
impact the deck or composite deck-slab assembly. This
primer is suitable for use in many UL fire rated assemblies.
D PANEL

The prime paint is intended to be an impermanent interim


coating to protect the bare cold-rolled steel, for a short Figure 1.2.5: SMOOTH SERIES™ RIVET ATTACHMENT
period, from ordinary atmospheric conditions prior to (Pictured from topside)
weathertighting the building. Prime Shield® should receive
a finish paint system if left exposed in the interior of a The new Smooth Series™ rivet attachment is flush with the
building. This 0.3mil water-based acrylic primer provides a exposed bottom surface, eliminating “bumps” and burn
good base for most field-applied paint systems. ASC Steel marks and the need for touch-ups in the field. Smooth
Series rivets are available in galvanized and white finish,
ACUSTADEK®

Deck is not responsible for the adhesion of paint systems


applied in the field. complementing our factory applied Prime Shield® primer
gray and white finish cellular deck. The high quality rivet
ASC Steel Deck may substitute ASTM A653 G01 galvanized steel deck for ASTM A1008.
1 attachments are uniformly repeated along the deck profile.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 7


TABLE OF CONTENTS

1.2 Product Offer

This product should not be used in floor assemblies where


spray on fire proofing is to be applied to the bottom surface
of the deck.

Cellular deck beam and pan may be manufactured out of the


same gage or out of different gages. The following shows
how to correctly specify the desired beam and pan gage
combination.

Specify Cellular Deck Gage “xx/yy”


• The first (xx) is the gage of the beam (top fluted section)
• The second number (yy) is the gage of the pan (the bottom
flat section with the side seam)
Figure 1.2.7: 3WxH-36V WITH VENTING
Venting
(Pictured from topside)
Some materials in building assemblies, including composite or
non composite steel deck, may require the deck to be vented.
Venting does not impact structural performance of steel deck
and has no bearing on fire ratings. Venting does not influence
the rate at which the concrete moisture content drops during Vent Tabs
curing of the slab on the deck. All ASC Steel Deck composite decks including; BH, NH, 2WH,
and 3WxH deck, have upward protruding vent tabs which
Some materials that are bonded by adhesives to the surface are factory punched in the low flutes of the steel deck when
of the concrete slab on the composite deck may be sensitive venting is specified. (See Figures 1.2.6, and 1.2.7) C0.9-
to the moisture content of the concrete. Venting is sometimes 32 and C1.4-32 do not have a venting option. CP-32 roof
specified, with the intent of creating a route for moisture to deck may be used as an alternate to C1.4-32 when venting
escape from the bottom of the concrete through the steel is required. The CP-32 has embossments in the side lap
deck vents. Research performed by the Expanded Shale Clay that holds the side lap open creating a vent at each side.
and Slate Institute, however, demonstrated that venting has
no bearing on how quickly the moisture content of concrete Die Set Ends (Swage)
on steel deck decreases (concrete drying time)2. Die set ends allow for deck panels to be end lapped. This is
not a common practice for composite deck but is common
Deck should not be specified as vented when it is not required for roof decks. The die set swages the top flange and webs
by another materials' performance specification. The drawback of the steel deck which allows the top sheet of end lapped
of venting deck is that when concrete is poured, the slurry drips deck to nest tightly over the bottom sheet. When deck is
through the vent tabs creating debris on the surface below. not die set, the installer may have to hammer the deck to
Cleaning up the slurry or protecting the surfaces underneath get the ends to nest together tightly to ensure good quality
with plastic sheets adds cost to the project without providing connections. The die set ends are standard for BH-36 and
any added value to the owner when venting is not required. NH-32 profiles. BH-36 is optionally available without die set
The requirement for venting the deck should be clearly ends. 2WH-36, 3WxH-36, Deep Deck, and cellular profiles
indicated in the specifications and be clearly stated in the are not end lapped and do not have die set ends. Figure
deck schedule on the structural drawings to avoid confusion. 1.2.8 shows a die-set end on NH-32 deck.

Note: 2. Craig, Peter A. (2011) Lightweight Concrete Drying Study. Chicago, IL: Expanded
Shale Clay and Slate Institute

Figure 1.2.6: BH-36V WITH VENTING Figure 1.2.8 N-32 WITH DIE-SET (Swage)
(Pictured from underside)

8 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Product Approvals 1.3

GENERAL INFORMATION
MALE SIDE SEAM

DIE SET END

1st RUN OF DECK

3W PANELS
2nd RUN

ASC Steel Deck conducts extensive test and engineering


programs with independent testing labs to ensure
FEMALE SIDE SEAM that our products comply with the stringent criteria of
END LAP today’s building codes. The structural performance of
our composite and non-composite steel deck products
Figure 1.2.9: DECK LAYOUT
have been verified and evaluated by reputable evaluation
Die set ends affect detailing and layout of the steel deck. Deck agencies, such as the International Association of

2W PANELS
is spread in the direction of the male leg of the side seam. Plumbing and Mechanics Officials Uniform Evaluation
This allows the next sheet’s female side seam to drop over Services (IAPMO-ES), Los Angeles City Research Reports
the male side seam. The die set is on the left side relative to (LARR), and Underwriters Laboratory (UL).
the direction of spreading deck. The next adjacent run of deck
will be on the left side of the deck relative to the spreading IAPMO-ES
direction to nest over the dies set ends. (See figure 1.2.9) ASC Steel Deck's composite and non-composite
steel deck panels are independently evaluated for
Exposed Deck conformance with the IBC by IAPMO-ES. IAPMO-
ES is accredited by the American Standards Institute

B PANELS
ASC Steel Deck roof and floor deck products are designed
to be structural components for steel framed structures. As (ANSI) per ISO/IEC Guide 65 General Requirements for
part of the normal manufacturing, handling, and transport Bodies Operating Product Certification Systems. LA
procedures, it is common for the panel bundles to exhibit City Research Reports (LARR) for ASC composite and
some degree of incidental scratching and denting. The non-composite steel decks are derived from IAPMO-ES
surface defects are typically superficial and do not impact reports. The technical evaluation for conformance with
the structural capacity of the deck. On projects where the the IBC is made available to code officials, contractors,
deck will be exposed to view after installation, it may be specifiers, architects, engineers, and others. IAMPO-ES
desirable to minimize the occurrence of these marks. In reports provide evidence that ASC Steel Deck products

N PANELS
these cases, it is important for the designer specifying and meet the most rigorous standards and are compliant
the customer or contractor ordering the deck to request that under current code requirements.
the product be manufactured, handled, and transported for
"EXPOSED" installation. This will result in modified handling Underwriters Laboratories UL-Fire Ratings
and loading procedures designed to minimize (not eliminate) ASC Steel Deck products which bare the UL approved
typical scratching and denting. Figure 1.2.10 and 1.2.11 mark have been investigated for fire resistance.
shows typical handling marks from forklifts or dunnage. Underwriters Laboratories is an independent, product
safety testing and certification organization. ASC Steel
Deck has been evaluated for fire resistance per UL 263

C PANELS
Fire Tests of Building Construction and Materials. See UL
directory for fire rated assemblies.

The Fire Ratings table (See figure 1.4.1) offers a quick


reference summary of design numbers, fire ratings, deck
type, SFRM Spray Applied Fire Resistive material listings
and more. The details of each design assembly are listed on
the UL Online Certification Directory www.ul.com.
D PANEL

Figure 1.2.10: UNDERSIDE HANDLING MARKS


ACUSTADEK®

Figure 1.2.11: TOPSIDE HANDLING MARKS

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 9


TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr
None
W8x15, 10J3, 12K1, 20LH (ceiling
D216 with a minimum of 13 lbs per foot weight
1, 1-1/2, 2, 3 6x6 W1.4xW1.4
system
none
below)

Mineral Mineral
D303 W8x28 1, 1-1/2, 2 6x6 10x10 SWG fiber fiber
board board

none
(ceiling
D502 W8x28, 20" Joist Girders at 20plf, 12K1, LH Series joists 1-1/2, 2 6x6 W1.4xW1.4
system
none
below)
D703 W8x20 1, 1-1/2 6x6 W2.9xW2.9 SFRM SFRM

D708 W10x17 1-1/2,3 6x6 W2.9xW2.9 SFRM SFRM

D712 W8x24 1-1/2, 2 6x6, 10x10 SWG SFRM SFRM

D722 W6x12 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D739 W8x28, W6x12,OWSJ, Cast in place concrete beams 1, 1-1/2, 2, 3, 4 6x6 W2.9xW2.9, Synthetic fibers SFRM SFRM

D740 W10x15 1 6x6 10x10 SWG SFRM SFRM

D743 W8x20, W8x28, W8x15, Cast in place concrete beams 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

D750 W8x21 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D754 W8x28 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D755 W8x24, W8x28, 10H3, 12J6 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

10 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number

3W PANELS
Note
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
varies
depending
"147-153 NW
1, 1-1/2, 2, 3 on accustic
107-113 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3 D216

2W PANELS
material,
see UL listing
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
1 1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
3/4 or 1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N

B PANELS
1 1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
D303
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
1 2 5/8 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N

N PANELS
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N

1-1/2, 2 2 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 3 D502

"142-148 NW
1, 1-1/2, 2, 3 2 1/2
105 LW" ✓ ✓ ✓ ✓ N 3 D703
"145-151 NW
D708

C PANELS
3 2 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3
109-115 LW"
"147-153 NW
1, 1-1/2, 2 2 1/2
110 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D712
"142-148 NW
1, 1-1/2, 2 2 1/2
112 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D722
"142-148 NW
102-120 LW
1, 1-1/2, 2, 3, 4 2 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D739
D PANEL

(110 LW with
joists)"
2 2 1/2 147-153 NW ✓ ✓ ✓ ✓ N D740
"147-153 NW
1, 1-1/2, 2, 3 2
107-113 LW" ✓ ✓ ✓ ✓ N 3 D743
"142-148 NW
2 2 1/2
105-111 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D750
ACUSTADEK®

3, 4 3 1/4 115-121 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D754


"147-13 NW
2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D755

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 11


TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr
6x6 W1.4xW1.4 with beams,
D759 W8x28, 12K5, 12" deep OWSJ at 7.1plf 1, 1-1/2, 2, 3 6x6 W2.9xW2.9 with joists, Fiber SFRM SFRM
reinforcement

D760 W8x28, OWSJ 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM

D764 W8x28, OWSJ 2 6x6, 6x6 SWG SFRM SFRM

6x6 W1.4xW1.4 with beams, 6x6


D767 W8x28, W6x12,OWSJ, Cast in place concrete beams 1, 1-1/2, 2, 3, 4
W2.9xW2.9 with OWSJ
SFRM SFRM

D768 W10x17 1-1/2, 3 6x6 W2.9xW2.9 SFRM SFRM

D775 W8x21 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D779 W8x28, 8K1 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4, Synthetic fibers SFRM SFRM

D782 W8x28, 10" Deep OWSJ 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM

D788 W8x28, 10K1 1, 1-1/2, 2, 3, 4 6x6 8x8 SWG SFRM SFRM

D794 W8x28, OWSJ 2 6x6 6x6 SWG SFRM SFRM

6x6 W1.4xW1.4 with beams, 6x6


D795 W8x28, OWSJ 1, 1-1/2, 2, 3
W2.9xW2.9 with OWSJ
SFRM SFRM

6x6 10X10 with beams, 6x6


D798 W8x28, OWSJ 1, 1-1/2, 2, 3, 4
W1.4xW1.4 with OWSJ
SFRM SFRM

6x6 W1.4xW1.4 with beams, 6x6


D799 W8x28, 10K1 1, 1-1/2, 2, 3
W2.9xW2.9 with OWSJ
SFRM SFRM

D825 W8x17 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D826 W8x20 0 6x6 W1.4xW1.4 SFRM SFRM

D832 W8x24, W8x28 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

D833 W10x25 2, 3 WWF Optional SFRM SFRM

D840 W8x28 0 6x6 10x10 SWG SFRM SFRM

D858 W10x25, Concrete beam 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM

D859 W8x20 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

12 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number
Note

3W PANELS
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
"147-13 NW
1, 1-1/2, 2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D759

"144-150 NW

2W PANELS
2, 3, 4 2 1/2
107-113 LW" ✓ ✓ ✓ ✓ ✓ N D760
2 2 1/2 117 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D764
"142-148 NW
102-120 LW
1, 1-1/2, 2, 3, 4 2 1/2
(110 LW with ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D767
joists)"
"145-151 NW
3 2 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D768

B PANELS
109-115 LW"
"142-148 NW
2 2 1/2
105-111 LW" ✓ ✓ ✓ ✓ ✓ ✓ N/A D775
"142-148 NW
1, 1-1/2, 2, 3, 4 2 1/2
102-120 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D779
1, 1-1/2, 2, 3, 4 3 1/4 115-121 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D782
"NW
1, 1-1/2, 2, 3, 4 2 1/2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D788

N PANELS
LW"
"147-153 NW
2 2 1/2
117 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D794
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ ✓ N D795
"142-148 NW
1, 1-1/2, 2, 3, 4 2 1/2
107-113 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ N/A D798

C PANELS
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D799
"147-153 NW
2 2 1/2
105-111 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D825
2 3 1/4 108-114 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D826
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N 3 D832
D PANEL

"147-153 NW
2, 3 2 1/2
109-115 LW" ✓ ✓ ✓ ✓ N 3 D833
3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D840
3 1/2 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
"147-153 NW
1, 1-1/2, 2, 3, 4 2 1/2 ✓ ✓ N/A 3 D858
ACUSTADEK®

108-115 LW"
"142-148 NW
1, 1-1/2, 2, 3 2
108-115 LW" ✓ ✓ ✓ ✓ N 3 D859

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 13


TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr

D861 W8x15, W10x25 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D862 W8x21 1 6x6 W1.4xW1.4 SFRM SFRM

D867 W8x18 1-1/2, 2 6x6 6x6 SWG SFRM SFRM

D871 W8x21, Concrete beam 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

D875 W8x20 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

D877 W8x17 1, 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D878 W8x20 0 6x6 W1.4xW1.4 SFRM SFRM

D883 W8x24, W8x28 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

D884 W10x25 2, 3 WWF Optional SFRM SFRM

D888 W8x28 0 6x6 10x10 SWG SFRM None

D891 W10x25, Concrete beam 1, 1-1/2, 2, 3, 4 6x6 W1.4xW1.4 SFRM SFRM

D892 W8x15, W10x25 1-1/2, 2 6x6 W1.4xW1.4 SFRM SFRM

D893 W8x21 1 6x6 W1.4xW1.4 SFRM SFRM

D898 W8x21, Concrete beam 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 SFRM SFRM

W12x14, W8x28, W8x24, 6x6 10x10 SWG,


D902 1, 1-1/2, 2, 3 SFRM none
W6x21, 8K1, 12K5, OWSJ Fiber reinforcement

14 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number
Note

3W PANELS
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
"137-150 NW
2 2 1/2
107-115 LW" ✓ ✓ N D861
2 2 1/2 99-105 LW ✓ ✓ ✓ ✓ N/A D862

2W PANELS
"144-150 NW
3 -
107-113 LW" ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N D867
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
108-115 LW" ✓ ✓ ✓ N 3 D871
"142-148 NW
1, 1-1/2, 2, 3 2
108-115 LW" ✓ ✓ N/A 3 D875
"147-153 NW
2 2 1/2
105-111 LW" ✓ ✓ N/A 3 D877

B PANELS
2 3 1/4 108-114 LW ✓ ✓ ✓ ✓ ✓ N/A 3 D878
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
109-115 LW" ✓ ✓ N/A 3 D883
"147-153 NW
2, 3 2 1/2
107-115 LW" ✓ N/A 3 D884
3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓
D888

N PANELS
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ N/A
3 1/2 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
"147-153 NW
1, 1-1/2, 2, 3, 4 2 1/2
108-115 LW" ✓ ✓ N/A 3 D891
"137-150 NW
2 2 1/2
107-115 LW" ✓ N/A 3 D892
2 2 1/2 109-115 LW ✓ ✓ N/A D893

C PANELS
"147-153 NW
1, 1-1/2, 2, 3 2 1/2
108-115 LW" ✓ ✓ N/A 3 D898
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 1/2 107-113 LW Y
D PANEL

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D902
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 5/8 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
ACUSTADEK®

2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 15


TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr
D907 W8x17, W8x28 0 6x6 W1.4xW1.4 SFRM none
D914 W8x28 0 6x6 W1.4xW1.4 SFRM none

D916 W8x28, OWSJ 0 6x6 10x10 SWG SFRM none

D918 W8x20 0 6x6 W1.4xW1.4 SFRM none

D919 W8x28 0 6x6 W1.4xW1.4 SFRM none

D920 W8x28 0 6x6 W1.4xW1.4 SFRM none


D922 W8x28, OWSJ 0 6x6 10x10 SWG SFRM none

16 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number
Note

3W PANELS
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
2 3 1/4 110 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y D907
3/4, 1 2 1/2 110 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y D914
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

2W PANELS
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3/4 or 1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D916
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

B PANELS
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 5/8 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 3 1/2 150-156 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

N PANELS
1-1/2 4 150-156 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 150-156 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 150-156 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y 4, 5 D918
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

C PANELS
2 3 1/2 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D PANEL

1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D919
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
ACUSTADEK®

2 3 1/4 110-120 LW ✓ ✓ ✓ ✓ Y D920


Refer to D916 for these values. D922
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 17
TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr

D923 W8x28 0 6x6 10x10 SWG SFRM none

Synthetic fibers,
D924 W8x28 0
negative reinforcing steel
SFRM none

6x6 10x10 SWG or negative bending


D925 W8x28, W8x16, 8K1 OWSJ 0
reinforcement with synthetic fibers
SFRM none

D927 W8x28, OWSJ 0 6x6 10x10 SWG SFRM none


D929 W8x28 0 6x6 10x10 SWG SFRM none
D931 W8x28 0 or 1 6x6 10x10 SWG SFRM none
D949 W8x28 0 6x6 10x10 SWG SFRM none

D957 W12x14, W8x28, W8x24, W6x12, OWSJ 1, 1-1/2, 2, 3 6x6 10x10 SWG none

18 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number

3W PANELS
Note
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

2W PANELS
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D923
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

B PANELS
1 2 5/8 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/2 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/8 142-148 NW ✓ ✓ ✓ ✓ ✓ N/A 4
2 4 3/8 142-148 NW ✓ ✓ ✓ ✓ ✓ N/A 5
2 3 1/8 105-111 LW ✓ ✓ ✓ ✓ ✓ N/A
D924

N PANELS
3 5 142-148 NW ✓ ✓ ✓ ✓ ✓ N/A 4
3 5 3/8 142-148 NW ✓ ✓ ✓ ✓ ✓ N/A 5
3 4 105-111 LW ✓ ✓ ✓ ✓ ✓ N/A

Refer to D902 for these values. D925


Refer to D916 for these values. D927
Refer to D916 for these values. D929

C PANELS
Refer to D902 for these values. D931
Refer to D916 for these values. D949
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D PANEL

1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D957
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 5/8 107-120 LW Y
ACUSTADEK®

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 19


TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Fire Proofing2
Unrestrained On
UL Design

Assembly
Number

Minimum Concrete
Minimum Beam or Joist Rating8 Reinforcing
Beam Deck
hr
D967 W8x28 0 6x6 W1.4xW1.4 SFRM none

D968 W8x28 0 6x6 W1.4xW1.4 none

D973 W8x28 0 Fiber - Ultra Fiber 500 none


D974 W8x28 1-1/2 6x6 10x10 SWG none
D975 W8x28, W8x24, W6x12 1, 1-1/2, 2, 3 6x6 10x10 SWG none
D976 W8x28 OWSJ 1, 1-1/2, 2 6x6 8x8 SWG none
D977 W8x28, OWSJ 1, 1-1/2 6x6 8x8 SWG none

D985 W8x28, 10K1 0 6x6 10x10 SWG none

D988 W8x28, 10K1 1, 1-1/2, 2, 3 6x6 W1.4xW1.4 none


Table Notes:
1. This table summarizes ASC Steel Deck's UL fire listings. Refer to the UL website for the most accurate and up-to-date listings.
2. SFRM = Spray-Applied Fire Resistive Material.
3. ASC Steel Deck may be used as blend deck with other manufacturers electrified cellular deck or trench.
4. Carbonate Aggregate.
5. Siliceous Aggregate.
6. BK Holding Corp. Ultra Fiber 500®
7. Syntheon Inc. Elemix® XE and Grey XE concrete additive.
8. For restrained fire ratings see UL listng for additional requirements.

20 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Fire Ratings 1.4

GENERAL INFORMATION
Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Smooth SeriesTM Option


Restrained Concrete Deck3

UL Design
Assembly

Number

3W PANELS
Note
3WxHF-36
Rating8 Thickness Type

BHN-351⁄4

2WHF-36
3WxH-36
CF 1-3/8

2WH-36
BHN-36

NHN-32
BHF-36

NHF-32
BH-36

NH-32
hr in pcf
3/4, 1 2 1/2 110 LW ✓ ✓ ✓ ✓ ✓ N/A D967
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

2W PANELS
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
D968
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y

B PANELS
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Y
2 3 3/4 142-148 NW ✓ N/A 6 D973
3 4 1/2 114-120 NW ✓ N/A 7 D974
Refer to D957 for these values. D975
1, 1-1/2, 2 3 1/2 111-117 NW ✓ N/A 7 D976

N PANELS
1, 1-1/2, 2 3 1/2 112.5-106.5 LW ✓ ✓ N/A 7 D977
1 3 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
1-1/2 4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 4 1/2 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
3 5 1/4 147-153 NW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
3/4 or 1 2 1/2 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N

C PANELS
1-1/2 3 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
D985
2 3 1/4 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 3 1/4 107-116 LW ✓ ✓ ✓ ✓ ✓ N
3 4 3/16 107-113 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
1 2 5/8 107-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
2 3 1/2 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
D PANEL

3 4 7/16 114-120 LW ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ N
Refer to D902 for these values. D988
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 21


TABLE OF CONTENTS

1.5 Steel Deck Section Properties

Section Properties
All of ASC Steel Deck's section properties are calculated of the compression elements decreases as the localized
in accordance with the American Iron and Steel Institute plate-like buckling increases. The bending capacity of the
Specification for the Design of Cold-Formed Steel deck increases with the increase in the grade of steel even
Structural Members, AISI S100-2012, Section B. Section though the effective section properties are decreasing.
properties can be used to develop the bending capacity The increasing strength of the steel outpaces the decrease
of the steel deck for out-of-plane loads, which are in effective section properties leading to higher bending
typically defined by gravity for composite decks carrying capacities. Steel deck cannot be compared based strictly
construction and fluid concrete loads. on effective section properties without considering the
grade of the steel because of the effect on the effective
The section properties for steel floor deck, like other cold- section properties by the grade of steel. Figure 1.5.1
formed steel members such as Cee, Zee, hat-shaped demonstrates this for BH-36 steel deck.
purlins, studs, and track are based on post-buckling
strength. Post-buckling strength is based on the concept 20 Gage BH-36 Steel Deck Panel
that compression flanges and portions of webs will exhibit Ie+ Ie- Se+ Se- Mn+
some local buckling prior to the load capacity of the Yield ksi (in4/ft) (in4/ft) (in3/ft) (in3/ft) (Kip-in/ft)
member being reached. To account for this, the widths of 33 0.193 0.237 0.235 0.251 4.65
the flat compression elements of the steel deck are reduced
37 0.187 0.233 0.233 0.247 5.17
for the purpose of determining the section properties,
excluding the portion that can no longer effectively carry 40 0.187 0.233 0.232 0.244 5.56
compression loads. This reduction of the gross section 50 0.177 0.227 0.228 0.236 6.83
properties results in the effective section properties. 55 0.177 0.227 0.227 0.233 7.34
80 0.173 0.223 0.218 0.230 7.84
Steel Thickness
The thickness of steel floor deck is typically specified Figure 1.5.1: EFFECTIVE SECTION PROPERTIES
by a gage designation. The design of steel deck is
dependent on the specified design base steel thickness Many steel deck panels are not symmetric. In most cases,
in accordance with AISI S100-2012. The base steel the top and bottom flange widths are not equivalent. The
thickness should not be confused with the total coated bending stress and location of the neutral axis is therefore
thickness, which is the combined thickness of the base different for positive and negative bending, resulting in
steel, the optional galvanizing thickness, and any factory- different positive and negative section properties.
applied paint system thickness.
Gross Section Properties
The minimum acceptable base steel thickness to be The gross section properties of the steel deck are based
supplied shall not be less than 95% of the design on the entire cross section of the panel. Determination
base steel thickness. This is specified in Section A2.4 of gross section properties assumes that there is
Delivered Minimum Thickness of AISI S100-2012. compression buckling of the compression flanges or
web elements of the steel deck, therefore there are no
Some standards reference non-mandatory tables that list the ineffective elements. The gross section properties are
thickness of sheet steel by gage designation. These include used in combination with effective section properties to
the AISC Manual of Steel Construction in the Miscellaneous determine the deflection of the steel deck under uniform
Information section of the appendix and AWS D1.3 in the out-of-plane loads and for checking axial compression
Annex. Both references indicate that the values are non- and bending.
mandatory and are for reference only. The nominal total
coated thicknesses listed for each gage in these sources Service Load Section Properties
should not be used to determine if the cold-formed steel The service load moment of inertia is used to determine
structural member, including steel deck, meets the minimum the deflection of the steel deck for out-of-plane loads.
thickness requirement for the specified gage. The calculated moments of inertia are determined at
a working stress level of 0.6Fy. Following accepted
Effective Section Properties practice, the hybrid moment of inertia is based on the
Effective section properties for a steel deck panel are sum of two times the effective moment of inertia, and
used to check for the maximum bending and axial load the gross moment of inertia divided by three, as follows:
capacities.
2Ie + I g
The effective properties are determined at the full yield Id =
stress of the steel. As the grade of steel increases, the 3
effective section properties decrease. The effective width

22 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Steel Deck Section Properties 1.5

GENERAL INFORMATION
How to Read Section Properties Table

3W PANELS
Weight of Gross Section Properties are
Panel Section Identified by the Subscript, g
Per SQFT

Base Metal Thickness Effective Section Properties


Panel Gage (without Coating) are Identified by the
Subscript, e

2W PANELS
B PANELS
N PANELS
Effective Net Area
Positive and Negative
of Section
Effective Moment of Inertia
for Non-Uniform Load
Conditions
Effective Section Hybrid Moment of

C PANELS
Properties at Inertia for Uniform Load
Service Load Condition Only
Conditions

Figure 1.5.2: SAMPLE OF PANEL PROPERTIES TABLE D PANEL

This deflection equation for uniformly distributed loads with high bending stress that are at or above the onset
takes into account that throughout the length of the of localized compression buckling exhibit progressively
span, portions of the steel deck will have low bending lower effective section properties as the bending stress
stress and others will have high bending stress. The goes up. Using the weighted average of the gross and
ACUSTADEK®

areas with low bending stress exhibit behavior based on effective section properties is an effective method to
gross section properties because the stress is below the address deflections in which section properties change
onset of localized compression buckling. The portions depending on the bending stress.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 23


TABLE OF CONTENTS

1.6 Web Crippling

Steel Deck Reactions at Supports Point or Line Load Reactions


Steel deck reactions at supports are governed by the For load conditions that exceed the uniform reaction
web crippling capacity of the steel deck webs on the capacity tables, including point loads and line loads on
supporting member. This is calculated in accordance with the steel deck panel, the maximum reaction capacity
Section C3.4 of AISI S100-2012 for multi-web steel decks. should be based on the web crippling capacity for the
steel deck. For reactions exceeding the published values,
Reactions Due to Uniform Loads or for conditions other than a uniformly distributed load,
The end and interior reactions listed in the tables in this the maximum reaction capacity shall be determined by
catalog are for a uniformly distributed out-of-plane load the designer in accordance with section C3.4 of the North
applied to the deck (See figure 1.6.1 and 1.6.2). American Specifications for the Design of Cold-Formed
Steel Structural Members for multi-web steel panels and
the geometric constants presented in the web crippling
UNIFORM DISTRIBUTION LOAD tables for the deck panel.

R
REA, INTER
R, EN CTIO IOR
D RE N (p
ACT lf )
ION (p
lf )

Figure 1.6.1: UNIFORM DISTRIBUTED OUT-OF-PLANE LOAD

The allowable Rn/Ω and factored ϕRn reactions presented


in the tables are in pounds per linear foot running axially
along the support for a given deck-bearing length on the
support (the support member width that the deck bears
on). This is based on the web crippling capacity multiplied
by the number of webs per foot. Figure 1.6.3 shows how
to read the reaction tables in this catalog.

Panels must be attached to supports with fastener


patterns not less than the minimum attachment patterns
shown for the deck panel.

UNIFORM LOAD (psf)

UNIFORM LOAD (psf)

R R

UNIFORM LOAD (psf) INTERIOR


BEARING
LENGTH
Figure 1.6.2: SUPPORT REACTIONS

24 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Web Crippling 1.6

GENERAL INFORMATION
How to Read Web Crippling Table

3W PANELS
Support Condition: Deck Panel End on Supports
or Deck Panel Continuous Over Supports

ASD Design Basis

Panel Bearing Length of Deck Panel Web


Gage on Support

LRFD Design

2W PANELS
Basis

Gage

B PANELS
N PANELS
Deck Panel Geometry

Allowable Reaction of Deck Panel on Interior

C PANELS
Support with 2″ of bearing

Allowable Reaction of Deck Panel


on End Support with 1.5 Bearing

Figure 1.6.3: SAMPLE OF WEB CRIPPLING TABLE


D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 25


TABLE OF CONTENTS

1.7 Steel Deck as a Concrete Form

Introduction
The design of deck as a form for concrete is based on ANSI/ minimum recommended loads and load combinations
SDI C-2011 for composite deck and ANSI/SDI NC-2010 for steel deck as a form. This includes the dead weight
for non-composite deck. The deck acts as a permanent of concrete, and 20 psf uniform construction live load or
form for the concrete. In addition to providing formwork 150 lbs concentrate load per foot width of deck. Heavy
for the concrete, the deck provides the tension reinforcing equipment loads from concrete buggies, drive on deck
for composite deck-slab systems. The deck also provides laser screeds, and ride-on power trowels exceed the
a safety floor for erection and a working platform for minimum design loads. It is critical that the maximum
construction trades. It is critical that the deck be designed to unshored spans be checked by the designer of record or
carry these loads to meet the expected performance. the engineer responsible for the erection for the structure
for heavy equipment loads on deck used as a form.
Maximum Unshored Span Tables
The maximum unshored spans for single and uniform double ANSI/SDI C-2011 basic ASD combinations include the
or triple deck span conditions are included in the load following used to develop the tables in this report.
tables for the deck in this catalog. This provides an easy
to use design aid to help select the appropriate deck type Wdc+wdd+wlc ANSI/SDI C-2011 Eq 2.4.1
and gage for a particular span. The maximum unshored Wdc+wdd+Plc ANSI/SDI C-2011 Eq. 2.4.2
spans are determined in accordance with ANSI/SDI C-2011.
This design standard provides the minimum recommended Wdd+wcdl ≥ 50psf ANSI/SDI C-2011 Eq. 2.4.2
loads the deck is required to support including the weight Wdc = dead weight of concrete1
of the deck, concrete, and 20 psf uniform construction live
Wdd = dead weight of the steel deck
load or 150 plf concentrated construction live load. These
maximum unshored spans may not be appropriate for heavy Wlc = uniform construction live load
construction live loads from concrete buggies, drive on deck (combined with fluid concrete) not less than 20psf
laser screeds, or ride on power trowels. Maximum unshored Wcdl = uniform construction live load
spans for loading conditions and span conditions that (combined with bare deck) not less than 50psf
exceed the load table should be determined by the designer
of record for the project or the engineer responsible for the Plc = concentrated construction live load per unit width
erection of the structure. of deck section; 150lbs on a one foot width

Loading Note:
In addition to considering the loading used to develop 1. For form decks (non-composite), additional concrete dead
the maximum unshored span in the tables, the definition load is required for single spans in accordance with ANSI/
of span and maximum reactions at supports need to be SDI NC-2010
considered. It is appropriate to consider the span as clear
span between supports when the supports have relatively Design of Steel Deck as a Form
ridged flanges as compared to the deflection of the deck. The design of deck as a form is a straight forward engineering
On supports without ridged flanges such as cold-formed exercise. The deck is no more than a cold–formed steel
Cees, Zees, open web steel joists, and thin ledger angles, beam spanning between the support framing. The provision
center-to-center span is more appropriate. of AISI S100 should be used to determine the strength of the
deck. The bending moment, web shear, and reactions are
The maximum spans may be governed by the maximum determined using engineering mechanics for slender beams.
reaction capacity of the composite deck at supports. ASC ANSI/SDI C-2011, Appendix 1, shows loading configurations
Steel Deck does not specify a minimum bearing length that are typically used for steel deck as a form. These do
of deck on a support, however, allowable and factored not address unequal spans and unique loading conditions.
reaction tables are presented for each deck type. This The maximum moment, web shear, and reactions are then
provides the maximum reaction for the deck based on the checked against the strength of the deck to determine the
bearing length of the deck on a support. This is limited by appropriate deck type and gage for a project.
the web crippling capacity of the deck. The deck span may
be limited by the maximum reactions for heavily loaded or The bending strength of a cold-formed steel deck should
long spanning deck. (See figure 1.6.2) be determined in accordance with AISI S100. Allowable
stress design is commonly used for determining the
Design Loads for Steel Deck as a Form bending capacity of the steel deck. Combined bending
Steel deck as a form should be designed to resist the and web shear is often ignored because the web shear
anticipated construction loads applied to the steel deck. stress is relatively small compared to the bending stress.
The design should meet the minimum design loads The section properties for steel deck are provided in
specified in ANSI/SDI C-2011 Standard for Composite this catalog to aid in the design of deck exceeding
Steel Floor Deck-Slabs. This standard provides the the scope of the maximum unshored span tables.

26 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Steel Deck as a Concrete Form 1.7

GENERAL INFORMATION
The reactions of the steel deck at supports should be
checked to ensure that the webs of the steel deck do not
buckle. The allowable web crippling of the deck may be

3W PANELS
taken directly from the web crippling tables in this catalog.
For conditions exceeding the scope of the tables, the web
crippling will need to be determined in accordance with
AISI S100. To help the designer, the flat width of the web
(h), bend radius (r), and angle relative to the support (ϴ) are
included in the tables.

It is important that deck used as a form does not over

2W PANELS
deflect. ANSI/SDI C-2011 limits deflection to L/180, but
not to exceed ¾ inch. The deflection check is based on
the weight of the deck and concrete using equations of
engineering mechanics. Skip loading and constitution
live loads are not considered because these loads are
not present after the concrete is finished and during the
curing time. For the maximum unshored span tables
presented in this catalog, ASC Steel Deck allows for an
additional 3 psf for normal weight concrete and 2 psf

B PANELS
for lightweight concrete to account for added concrete
due to deflection. ANSI/SDI C-2011, Appendix 1, has
equations for deflection for common conditions. The
actual deck deflection may vary from the predicted
deflection, however, the predicted limits have proven to
be reliable for the design of deck as a form.

Cantilevers

N PANELS
Cantilevering deck is an acceptable common solution to
extending the composite deck-slab past a support and
generally involves the use of a two piece pour stop as
shown in figure 1.7.1. Cantilevers need to be designed by
the engineer of record or the engineer responsible for the
erection of the structure. The section properties included in
this catalog provide the basic properties for this calculation.
The cantilever should be designed in accordance with
ANSI/SDI C-2011 section 2.4.

C PANELS
D PANEL

Backspan(s) Cantilever

Figure 1.7.1: Cantilevers


ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 27


TABLE OF CONTENTS

1.8 Composite Deck-Slab Design

General Design Principles


The design of composite steel deck-slab systems reflect the only warranted in conditions in which ASD is unfavorable.
basic engineering concepts used to design reinforced concrete An example would be a case in which a large portion of the
beams. The concrete acts as the compression material, and superimposed load is dead load. In these situations, a great
the steel deck bonded to the bottom of the concrete acts as portion of the load would use a 1.2 load factor for dead
the tension steel. In this manner, the composite deck-slab load, and a smaller portion of the load would use a 1.6 load
behaves like a simple reinforced concrete beam in which the factor for live load. In these cases, an LRFD approach will
deck is the rebar. prove to be more efficient if the maximum superimposed
load carrying capacity is governing the design. LRFD is a
A composite deck-slab is most commonly designed as a good choice for composite deck-slab systems supporting
simple span beam. The deck only provides positive bending heavy loads such as equipment pads and heavy planting
reinforcement. The minimum temperature and shrinkage beds for green roof systems or patio decks.
reinforcing is not adequate to develop negative bending
over supports. With out any significant negative bending Loading
reinforcement over supports, the concrete is assumed to Composite deck-slab systems are a very efficient way to
crack and the deck yield in negative bending, creating a support many design loads. The loads should be static or
condition in which the composite deck-slab is treated as a semi-static in nature. These are typical of dead loads and
simple beam. (See figure 1.8.1) typical commercial building live loads. Live loads that are
cyclic or vibratory in nature, however, may break down the
Tension Crack Tension Crack bond between the deck and slab over time. These loads
Uniform Load
should not be applied to composite deck-slab systems
without supplemental reinforcing. Loads to watch out for:

Vibratory or Cyclic Loads: Machinery that vibrates or


applies a repetitive cyclic load should be avoided. This
type of equipment may break down the bond between
the concrete and deck due to vibration or high and
localized bending and shear.
Figure 1.8.1: Single Span
Forklift Loads: Forklifts tend to create very high
The maximum load carrying capacity of a composite deck- localized wheel loads that apply significant localized
slab system should be limited to the bending capacity, bending and shear to the composite deck-slab system
vertical shear, and maximum acceptable deflection. ANSI/ and should be avoided.
SDI C-2011 provides the design methods for composite
steel deck-slab systems. The tables in this catalog provide Hard Wheeled Loads: Heavily loaded hard wheeled
an easy to use design aid following these methods. carts may apply high localized bending and shear
below the wheels that may approach the design
Superimposed Load Capacity capacity of the composite deck-slab system and
The superimposed load that the composite deck-slab should be avoided.
system carries are those loads that are in addition to the
concrete and deck self-weight. These loads consist of out- These types of cyclic or vibratory loads may be applied to
of-plane dead and live loads. Most composite deck-slab composite deck-slab systems if supplemental reinforcing
systems are designed using Allowable Stress Design (ASD). designed to carry the load is added to the concrete section.
This is a convenient method because either calculations or In this case, the deck is considered a stay in place form,
load tables can be developed based on service loads. ASD similar to a form deck.
design does not take into account the different load factors
for dead and live loads of 1.2 and 1.6 respectively. Most ASD Parking Structures: Composite deck-slab systems
superimposed load calculations and load tables assume have been used successfully for parking structures for
that the entire superimposed load is a live load using a load many years. The combination of the relative light weight
factor of approximately 1.6, which heavily favors live loads of automobiles with pneumatic tires that distribute the
and is therefore conservative for dead loads. ASD is best load and suspension, greatly reduce the effects of
suited for applications for which the majority of the load is dynamic cyclic loading on the composite deck-slab
live load, which is typical for most commercial building floor system. For open parking structures, it is recommended
applications. that the slab be sealed to reduce possible corrosion
of the steel deck from water penetrating cracks in
Load and Resistance Factor Design (LRFD) is a more the slab. Supplemental reinforcing in the slab is
efficient method of design for superimposed loads that are recommended in exposed conditions in which the deck
primarily dead load. This method is more involved and is could corrode over time.

28 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Composite Deck-Slab Design 1.8

GENERAL INFORMATION
Concrete Neutral Axis of
Composite steel deck utilizes structural concrete fill poured Deck-Slab at ≤ Fct
over the top of the steel deck. The design of the concrete Fc
should be in accordance with ACI 318 with a minimum

3W PANELS
compressive strength of 3000psi. ASC Steel Deck's load
tables are based on either 145 pcf normal weight concrete
or 110 pcf lightweight concrete. Composite deck systems
can be designed with lower or higher density light weight
concrete, but it is important that the effect on fire rating be Fs
considered if applicable to the project.
Fct
Neutral Axis
Temperature and Shrinkage Reinforcing of Steel Deck

2W PANELS
Reinforcing should be provided in the concrete to Figure 1.8.2: Uncracked Section
prevent temperature and shrinkage cracking. This can be
accomplished with welded wire fabric, reinforcing steel,
Cracked Section
or fibers. The minimum steel reinforcing should not be
The cracked section for composite deck-slab systems is
less than 0.00075 times the area of the concrete, but
determined using methods similar to reinforced concrete
not less than 6x6 Wl.4xWl.4 welded wire fabric. Steel
design. For composite deck-slab systems, this is determined
fibers may be used when the concrete is designed in
at a compressive yield stress in the concrete in which the
accordance with ASTM C1116 type I with steel fibers per
flexural stress is still assumed to be linear elastic and the
ASTM A820 type I, II or V, provided at the manufactures

B PANELS
concrete in tension is cracked and is no longer contributing
recommended dosage, but not less than 25lbs/cy.
to the section properties. (See figure 1.8.3) The cracked
Macro synthetic fibers may be used when the concrete
moment of inertia is presented in the composite deck tables
is designed in accordance with ASTM C 1116 type III,
in this catalog for common slab conditions. For conditions
with fibers in accordance with ASTM D7508 provided
exceeding the scope of the tables, the cracked moment of
at the manufacturers recommended dosage, but not
inertia should be calculated in accordance with ANSI/SDI
less than 4lbs/cy. Other types of fibers that effectively
C-2011 Appendix 4.
resist temperature and shrinkage cracking may be used
at the fiber manufactures recommended dosage. This is Neutral Axis of

N PANELS
appropriate because any increase in concrete strength Deck-Slab at Yield
Fc
that may result from temperature and shrinkage control
using fibers is not considered when developing the load
carrying capacity of the composite deck-slab.

Composite Deck-Slab Section Properties


The development of section properties for composite Fs
deck-slab assemblies follows the engineering mechanics
used to develop section properties for reinforced concrete

C PANELS
design. The convention in design of composite deck-slab Neutral Axis
systems is to use the transformed section to convert of Steel Deck
the area of steel into an equivalent area of concrete. Figure 1.8.3: Cracked Section
The transformed section properties are then used to
determine the nominal bending moment and predicted Bending Capacity
deflections for the composite deck-slab section. The flexural capacity for composite steel deck-slab
systems is determined using methods similar to reinforced
UnCracked Section concrete design. In this catalog, the nominal bending
The uncracked section for composite steel deck-slab capacity for deck-slab systems that are not anchored to the
D PANEL

systems is analogues to reinforced concrete design. structure with headed shear stud anchors are developed
The uncracked section properties are determined at low using the ANSI/SDI C-2011 prequalified method. This
bending stress, in which the concrete is still effective is referred to as the yield method in which the nominal
in tension. This is the condition in which the concrete bending moment is limited to the point at which the steel
in tension, has not cracked, and still contributes to the deck begins to yield. This is determined using the cracked
section properties. (See figure 1.8.2) The uncracked moment of inertia and the yield strength of the steel deck.
moment of inertia is presented in the composite deck The factored and allowable bending moments for common
tables in this report for common slab conditions. composite steel deck-slab systems are listed in the tables
ACUSTADEK®

For conditions exceeding the scope of the table, the in this catalog. For conditions exceeding the scope of
uncracked moment of inertia should be calculated in the tables, the bending capacity should be calculated in
accordance with ANSD/SDI C-2011 Appendix 4. accordance with ANSI/SDI C-2011 pre-qualified sections

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 29


TABLE OF CONTENTS

1.8 Composite Deck-Slab Design

method. The embossment factor (K) for this method is using the average of the cracked and uncracked section
presented in General Note 7 of section 1.18, Composite properties.
Deck-Slab Table General Requirements along with the
embossment geometry. Iu + Ic
Id =
Vertical Shear 2
The vertical shear capacity for a composite deck-slab
system is the combination of the shear contribution of the The average moment of inertia for deflection (Id) is presented
concrete and the steel deck. The factored and allowable in the tables in this catalog for common conditions. This can
vertical shears are presented in the tables in this catalog. be used to check the deflection for both lower and higher
For conditions that exceed the tables, the shear should deflection limits.
be determined in accordance with ANSI/SDI C-2011.
Concentrated Load
Deflection Concentrated point loads and line loads should be
The deflection of a composite deck-slab system should checked using the composite deck properties including
be checked to ensure serviceability of the system for the maximum bending moment, vertical shear, and
its intended use. The superimposed load tables in this moment of inertia for the deflection check. ANSI/
catalog have been limited to strength or L/360 deflection SDI C-2011 section 9 provides a general solution for
limit. L/360 was chosen because it is the typical live load concentrated loads on steel deck, including the design
deflection limit for floor systems. Deflection was checked of load distribution reinforcing in the slab.

30 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Non-Composite Deck-Slab Design 1.9

GENERAL INFORMATION
General Concrete Slab Design
Non-composite steel deck design assumes that the steel deck The design of a concrete slab above a non-composite deck
and concrete do not interact to develop composite sections should be in accordance with ACI 318. This includes bending
for bending. The design of non-composite deck should be capacity, vertical shear, and diaphragm shear. It is acceptable

3W PANELS
done in accordance with ANSI/SDI NC-2010 Standard for to ignore the contribution of the concrete in the flutes of the
Non-Composite Steel Floor Deck. The most common non- deck when designing the concrete section. For this method
composite deck design is to use the deck as a permanent of design, the minimum thickness of concrete above the steel
form and to design the reinforced concrete in accordance deck is 11⁄2 inches.
with ACI 318. Another less common option is to design the
deck to carry all the design loads, including the weight of the Temperature and Shrinkage Reinforcement
unreinforced concrete. For this option, the design of the deck The minimum reinforcing for temperature and shrinkage
should follow the provisions of AISI S100 Specification for the control should be in accordance with ACI 318.

2W PANELS
Design of Cold-Formed Steel Structural Members.
Non-Composite Deck Load Tables
Deck as a Form Non-composite deck uniform load tables are provided in
The design of deck as a form shall be in accordance with this catalog. The tables include the maximum unshored
ANSI/SDI NC-2010. Section 1.7 of this catalog discusses the span and the maximum uniform load capacity of the non-
design of deck as a form. composite deck.

B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 31


TABLE OF CONTENTS

1.10 Penetrations and Openings

General
Openings and penetrations in composite deck-slab floor and Cut-Out: an opening or penetration through the deck-
roof structures are a normal part of every building. These slab system in which the deck is placed, the penetration
can range from small pipe and conduit penetrations, to mid- or opening cut out, deck stiffeners or support frames
sized openings for mechanical ductwork, to large openings are installed (if required), the opening is flashed with
for stair wells or elevator shafts. Small penetrations less edge form or sleeving cans, then concrete is poured
than 12 inches across may not require much, if any, and allowed to cure.
structural design consideration unless several are grouped
closely together. Mid-sized openings up to 2 to 3 feet Penetrations or openings that are Decked-Over have several
across most likely require design consideration to address key advantages, including simplifying the design of the deck
the appropriate distribution of load around the opening for as a form and providing fall-protection safety for mid-size and
both deck as a form and the composite deck-slab system. large openings. When the Decked-Over approach is used,
Large openings are generally designed with support framing the steel deck bending capacity and vertical shear capacity
around the openings which is part of the overall framing for is not reduced from an opening being cut in the deck. In
the composite deck-slab floor or roof system. It is difficult to the Decked-Over case, no additional design effort needs
have a “rule-of-thumb” for unscheduled openings because to be considered because unshored spans do not change
of the wide variety of building conditions. The information as the bending capacity and vertical shear capacity have
in this section should provide guidance toward addressing not been reduced. Another advantage for mid-sized and
a wide range of penetrations and openings in the composite larger openings is that the deck provides the fall protection,
steel deck-slab system. eliminating the need to plank over or put up handrails around
the openings in accordance with OSHA regulations. The
Deck-Over or Cut-Out? primary disadvantage of Decked-Over openings is that they
The one major consideration which determines the complexity cannot be cut out and utilized until after the concrete slab
of designing penetrations or openings in the steel deck is has been poured and had adequate time to cure.
whether to Deck-Over or Cut-Out the deck. This impacts
how the penetration affects the deck as a form and what type Penetrations or openings that are Cut-Out have the advantage
of deck stiffeners or opening frames should be considered. of being immediately available for use. The disadvantage
For purposes of this catalog, when Decked-Over or Cut-Out of Cut-Out openings is that the opening in the deck is cut
are italicized they shall have the following definitions. out, therefore compromising the bending capacity and the
vertical shear of the deck in the area of the opening. For small
Decked-Over: an opening or penetration through the openings in most common conditions, the amount the deck
deck-slab system in which the deck is placed, the is compromised is insignificant and can typically be ignored.
penetration or opening is blocked out with formwork, For mid-size openings, the amount the deck is compromised
Styrofoam, or edge form flashings without cutting the is significant and will most likely require stiffening or a
deck, the concrete is poured and allowed to adequately structural support frame. Another disadvantage is that Cut-
cure, then the deck is cut out when the opening is Out openings also require fall protection planking or hand rails
needed. (See figure 1.10.1) to prevent injuries in accordance with OSHA regulations.

Small Size Penetrations


Small size penetrations of 12 inches or less often do not
require any structural design or detailing. These penetrations
Steel Parallel Edge Form are typically for pipes, conduits, or small ductwork. It is up to
the designer of record to determine whether specific design
and detailing is required for small size penetrations. The
following are common examples of methods to stiffen the
deck around small openings and penetrations which may be
considered by the designer.

Steel Perpendicular Edge Form Decked-Over small penetrations is the recommended method
because the designer does not need to consider whether
the penetration will affect the capacity of the deck as a form,
because the deck is not cut out. The only issue which may
need to be considered is load distribution around the opening.
If required, this can be accomplished by placing rebar to
Styrofoam Blockout distribute the loads around the opening. For most common
floor applications, this is not necessary for openings less than
Figure 1.10.1: DECKED-OVER OPENINGS 12 inches unless several are grouped together.

32 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Penetrations and Openings 1.10

GENERAL INFORMATION
Cut-Out small penetrations may require the stiffening of the rebar to distribute to the deck-slab adjacent to the openings.
deck. Most small openings less than 6 inches which do not (See figure 1.10.3) Reinforced concrete design to distribute
cut through more than 1 web of the deck does not require these loads perpendicular to the deck span should be done

3W PANELS
any reinforcing. Small Cut-Out penetrations less than 24 in accordance with ACI 318.
inches can be reinforced with stiffening angles, tube steel,
or channels attached to the deck. (See figure 1.10.2) These
details rely on the adjacent deck's reserve capacity to support
the load distributed to those flutes due to the penetration Cut-
Out. These distribution angles are an effective way to control Distribute
1
⁄2 Tributary
localized deck deflection around the penetration Cut-Out.
Load
They do not, however, address possible overstress or over

2W PANELS
deflection of the adjacent flutes of the deck now carrying the
load. Historically this type of detail has been demonstrated to
be an effective solution for small penetrations.
Collect
Tributary
Load

Distribute

B PANELS
1
⁄2 Tributary
Load Distribute
1
⁄2 Tributary
Load

Collect
Tributary
Load
Distribution Rebar Design
in Accordance with ACI 318

N PANELS
Figure 1.10.3: REBAR DISTRIBUTION
Distribute
1
⁄2 Tributary
Load
Cut-Out mid-sized openings require structural design and
detailing of the deck as a form and the composite deck
Load Distribution steel deck-slab. Cut-Out openings compromise the deck
Angle, Channel bending and shear capacity. For openings less than 2 feet,
or tube Steel stiffener angles may be an acceptable solution similar to
(Above or below
those used for small penetrations. The designer of record

C PANELS
the deck)
should verify the size of the stiffener and that the adjacent
Figure 1.10.2: DECK SUPPORT ANGLES deck can support the concrete and construction loads.
For all mid-sized openings, deck support frames may be
Mid-Size Openings a good option to support the deck for the concrete and
Mid-sized openings typically require some structural design construction loads. The designer of record should design
and detailing consideration. These openings are typically for and detail these frames around the mid-sized openings to
ductwork or other mechanical shafts. Mid-sized openings transfer the loads back to the primary framing members
range from 1 foot to approximately 4 feet and cut through supporting the composite steel deck. (See figure 1.10.4)
multiple webs of the composite steel deck. The following Steel angles or channels are common framing materials for
D PANEL

are common examples of how the design professional may mid-sized openings.
address mid-size penetrations in their designs.

Decked-Over mid-sized openings require less structural design


and detailing than Cut-Out. If the opening is Decked-Over,
the deck as a form is not compromised therefore no stiffening
angles or support frames are required. The design should
consider the effect of load transfer around mid-size openings
ACUSTADEK®

for the composite steel deck-slab design. The superimposed


load and dead load of the deck-slab needs to be distributed
around the opening. This can be accomplished by using

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 33


TABLE OF CONTENTS

1.10 Penetrations and Openings

Consideration for Groups of Openings


When small sized Cut-Out penetrations are grouped
together, the effect of the grouping may need to be treated
as a mid-sized or large sized opening. Groups of small
penetrations running along the edge of a support beam can
compromise a large portion of the vertical shear capacity of
both the deck as a form and the composite steel deck-slab
system. (See figure 1.10.5)

Opening Frame Channels,


Angles or Small Wide Flanges
Figure 1.10.4: DBL H OPENING FRAME

Large Openings
Large openings for stair wells, elevator shafts, or large
mechanical shafts are typically supported by framing which
is part of the primary building framing system supporting
the composite steel deck-slab system. Decked-Over large
openings are often not practical due to the large size of the Figure 1.10.5: ROW OF SMALL HOLES
opening. Most large openings do not fall into the Cut-Out
category because the deck will be detailed around the opening
with pour stops similar to edge of slab conditions.

34 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Penetrations and Openings 1.10

GENERAL INFORMATION
The effect of several small openings with stiffeners in The effect of two small holes in the same flute(s) of the
proximity to each other may affect the overall capacity of deck panel may need no more consideration than a single
the deck as a form or capacity of the composite deck-slab penetration. The load from the flutes with the penetrations

3W PANELS
system. This may be an issue when the stiffening angles or is distributed to the adjacent webs and is similar in
penetrations overlap in a given span. The designer should magnitude to a single penetration. (See figure 1.10.7)
consider the overlapping distribution of the load on the
deck between openings to ensure the bending capacity of
the deck is not exceeded (See figure 1.10.6)

When Perpendicular

Single Net Opening


to Flute Treat as
Distribute

2W PANELS
1
⁄2 Tributary
Load

Collect
Tributary
Load

Flute Treat as one


Distribute

When Parallel to

Small Opening
1
⁄2 Tributary

B PANELS
Load

Collect
Tributary
Load

Distribution Figure 1.10.7: SINGLE VS 2 PENETRATIONS

N PANELS
1
⁄2 Tributary
Load

Figure 1.10.6: OVERLAPPING HOLES

C PANELS
D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 35


TABLE OF CONTENTS

1.11 Composite and Non-Composite


Diaphragm Shear

General
A composite steel deck-slab is an integral part of a build- spacing of the fasteners per sheet shall not be greater than
ing's horizontal diaphragm system. The composite deck- the spacing of the parallel boundary fasteners. Fasteners
slab acts as a shear resistant membrane supported by the may need to be doubled up in some flutes to achieve this.
steel framing supporting the diaphragm and providing the
perimeter cords and collectors. The composite deck-slab
tables in this catalog provide an easy to use design aid with
factored diaphragm shears for common attachment types.

Shear Design of Diaphragms without Welded


Shear Studs
The diaphragm shear design of composite deck-slab
S
systems may be performed in accordance with the SDI
Diaphragm Design Manual. This method is used for deck
which is not attached with headed shear stud anchors.
Common attachment methods include arc spot welds,
power actuated fasteners, and self-drilling screws. The
side laps of the steel deck should be connected together to
prevent concrete leakage and provide some shear contri- ≤S
idth
bution. The minimum side lap connection should be button Panel Wasteners
u m b e r of F
N
punches at 36 inches on center.
Figure 1.11.1: SKEW DIAPHRAGM
Diaphragm Boundary Fasteners to Supports
The diaphragm boundary connections to supports, per- Diaphragm Deflection
pendicular to the deck, should be the specified attachment Composite deck-slab diaphragms are very stiff with a
pattern in the composite tables for the given deck gage, flexibility factor, f<0.5micro inches/lbs (Shear stiffness,
concrete type, and slab thickness. G’ > 2000 kip/inch). The specific predicted shear stiff-
ness (G’) for a given composite deck-slab condition can
Diaphragm boundary fastener spacing, parallel with the ribs be determined in accordance with the methods in ANSI/
of the deck, shall not exceed the spacing determined by: SDI C-2011. Due to the very stiff nature of these systems,
dividing the fastener shear strength by the required shear checking the shear deflection of the diaphragm is often not
demand. Connector shear strengths are presented in fig- necessary. There may be occasions, however, to check
ures 1.13.11 and 1.13.12 diaphragm shear deflections for diaphragms with large
length to depth ratios. For these conditions, the methods
Q fa  12in  and equations of engineering mechanics presented for
Spacing (in) =   diaphragm deflections in the ASC Steel Deck Roof Deck
sa  ft  Catalog may be used.

Diaphragm Shear With Headed Shear Stud Anchors


Q ff  12in  Diaphragms requiring diaphragm shears that exceed the
Spacing (in) =   limits of the arc spot welds, power actuated fasteners,
s f  ft  or self-drilling screws may be developed using headed
shear stud anchors and supplemental shear reinforcing
Qfa = Allowable fastener strength using the safety factor, in the concrete slab above the deck. This design is
Ω = 3.25, for composite deck-slab diaphragm based on the transfer of shear from the collector into the
shear in accordance with ANSI/SDI C-2011, lbs reinforced concrete slab above the deck using headed
shear stud anchors. The capacity of the diaphragm
Qff = Factored fastener strength using the safety factor,
is limited by this shear transfer, or the capacity of the
Φ = 0.5, for composite deck-slab diaphragm shear
reinforced concrete diaphragm above the deck. The
in accordance with ANSI/SDI C-2011, lbs
capacity of the headed shear stud anchors should be
Sa = Allowable shear demand, lbs/ft determined in accordance with AISC 360 requirements
for composite beam design. The in-plane shear capac-
Sf = Factored shear demand, lbs/ft
ity for the reinforced concrete diaphragm above the
deck should be determined in accordance with ACI 318
Skew Cut Diaphragm requirements for reinforced concrete design. The com-
At skew cut conditions, the minimum number of fasteners is posite deck-slab tables in this catalog provide factored
determined based on the location of the fasteners in the ribs diaphragm shear capacities for common reinforcing
per the perpendicular attachment schedule. The average schedules with ¾ inch diameter headed stud anchors.

36 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 37


TABLE OF CONTENTS

1.12 Composite Deck-Slab Tables

General
The composite deck-slab load tables are intended to provide factures have presented allowable shears. These shears
a designer with easy to use design aids for common compos- were based on research and engineering studies dating back
ite deck-slab conditions. The tables provide uniform load in to before LRFD was commonly used for steel design. The
both allowable and factored superimposed loads. Factored factored shears presented in this catalog work seamlessly
diaphragm shears are provided for composite deck-slab sys- with the design of the lateral force resting system for steel and
tems for lateral design. Diaphragms may be attached with concrete buildings designed using the LRFD approach. The
a variety of attachments to supports including traditional arc designer does not have to convert the lateral forces to ASD
spot welds, power actuated fasteners (PAF), and self-drilling when selecting a factored diaphragm from the shear tables.
screws. Factored shear tables for diaphragms with steel
reinforcing and headed shear stud anchors are provided for Factored shears are provided for a variety of fastener types
high shear diaphragms. All of these tables are supported with to supports. This range of fasteners reflects a full range of
complete composite deck-slab properties including bending building types that composite deck-slab systems are used in.
moment, vertical shear, and section properties to aid in the
design of conditions exceeding the scope of the tables. Wide Flange Multi-Story Steel Construction: Arc spot welds
are the traditional method for attaching composite deck to
Superimposed Uniform Load Tables structural steel support members. This method provides
Uniform superimposed load is the load which the composite good shear performance and is applicable to a wide variety of
deck-slab can carry in addition to its self-weight. Both allow- support steel, from heavy wide flange beams to light weight
able and factored superimposed loads are provided. The open web steel joists. Welded steel headed stud anchors are
superimposed load tables assume that the minimum tempera- commonly used for composite beam design. They are also a
ture and shrinkage reinforcement is not adequate to develop good choice to transfer large diaphragm forces into the com-
negative bending resistance at supports, therefore all spans posite deck-slab system. This system is ideal for high shear
are treated as simple spans. diaphragms on wide flange beams and requires the use of
welded wire fabric or reinforcing bars in the slab.
Most floor systems are designed using allowable stress design
(ASD). The allowable superimposed load tables present the Open Web Steel Joist Mezzanine and Floor Systems:
maximum uniform load based on the allowable bending Composite steel deck-slab systems can be attached with arc
strength, allowable vertical shear, and a deflection limit of spot welds, however, power actuated fasteners (PAF) are an
L/360. ASD assumes that the superimposed load is primarily ideal cost effective method of attachment to light structural
live load and is conservative for dead loads. angles used for open web steel joist framing. PAF selection is
dependent on the support steel thickness. (See figure 1.13.12)
Load and Resistance Factor Design (LRFD) is recommended
for conditions in which the majority of the superimposed load Cold-Formed Steel Mezzanine and Floor Systems: Self-
is dead load, and the maximum superimposed load is the drilling screws are the best choice for attaching composite
limiting design criteria. The factored superimposed loads in steel deck to cold-formed steel framing. Common examples
the tables do not include a deflection check. The designer will of this application include: cold-formed steel framed multi-
have to check the service load deflection to ensure that the story mini-storage buildings, mezzanines, and conventional
deflection meets the projects deflection serviceability require- cold-formed steel stud, and joist framed buildings.
ments when using an LRFD approach.
Composite Deck-Slab with Cellular Deck
Composite Deck-Slab Properties Cellular composite deck panels can be conservatively
For conditions exceeding the scope of the uniform load tables, designed using the non-cellular deck-slab tables. The super-
composite deck-slab properties are provided in the tables. imposed loads, vertical shear, and moment of inertia can be
The properties can be utilized as part of the solution for con- conservatively used for the design, based on the gage of the
centrated loads, deflection limits, or spans not included in the beam section of the cellular profile. This ignores the contribu-
superimposed load tables. The properties include both allow- tion of the steel used for the bottom pan of the cellular deck.
able and factored moments, and vertical shear for determining Maximum unshored spans for cellular deck-slab system are
the capacity of the composite deck-slab system. Cracked, listed with the cellular deck section properties.
uncracked, and the average of cracked and uncracked
moment of inertia are provided to assist in determining the Allowable Stress Design
deflection of the deck-slab system. Historically, most composite steel deck-slab systems dia-
phragm shear tables have been presented using an allowable
Factored Diaphragm Shear stress design basis. To compare composite steel deck-slabs
This catalog presents composite steel deck-slab diaphragm designed using ASD basis, it is recommended that the ASD
shears using a load and resistance factor basis. The dia- shear demand be converted back to an LRFD basis. This can
phragm shears presented are factored shears. Composite be accomplished by dividing the required allowable shear by
steel deck-slab systems have traditionally been designed 0.7 ASD seismic factor, for seismic controlled designs, or 0.6
using allowable stress design (ASD), in part because manu- ASD wind factor for wind controlled designs.

38 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Composite Deck-Slab Tables 1.12

GENERAL INFORMATION
How to Read Tables

3W PANELS
3WxH-36 Composite Deck
5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.080yd3/100ft2
Theoretical concrete
volume does not Vertical load
Maximum account for deflection span of deck
Clear Span Maximum Unshored Span (in)
without Allowable
Gage Single Double Triple Gage Single Double Triple

2W PANELS
Shoring superimposed
22 10' - 1" 11' - 0" 11' - 4" 19 12' - 3" 13' - 10" 14' - 4"
21 11' - 0" 11' - 9" 12' - 2" 18 12' - 7" 15' - 2" 14' - 9" live load capacity
20 11' - 9" 12' - 6" 12' - 11" 16 13' - 3" 16' - 7" 15' - 7"
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf) Factored
GA Vertical Load Span (in) 8'-0"
443 8'-6"
389 9'-0"
343 9'-6"
304 10'-0"
271 10'-6"
243 11'-0"218 11'-6"
197 12'-0"
178 12'-6"
162 13'-0"
147 13'-6"
134 14'-0"
122 14'-6"
111 15'-0"
102 superimposed
ASD, W/Ω
LRFD, ϕW 709 622 ASD 549 & LRFD
487 - Superimposed
434 389 349 Load, 315
W (psf)285 258 235 214 195 178 163 load
ASD, W/Ω
L/360 282
- 246
- 216
- 190
- 169
- 150
- 134
- 119
- 107
- 96
- 86
- 78
- 70
- 63
- 57
-
LRFD, ϕW 451 394 345 304 270 240 214 191 171 154 138 124 112 101 90
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18 L/360 - - - - - - - - - - - - - - - Superimposed
Arc Spot Weld 1/2" Effective Dia 2679 2634 2594 2587 2554 2523 2496 2470 2447 2448 2427 2408 2391 2374 2359 load that

B PANELS
PAF Base Steel ≥ .25" 2352LRFD - Diaphragm
2326 2303 2312 ϕSn (plf
Shear,2292 2274/ ft) 2258
36/4 Attachment
2243 2229Pattern
2238 2226 2214 2204 2194 2184
No load shown produces L/360
22 ArcPAF
SpotBase
WeldSteel
1/2" Effective
≥ 0.125"Dia 2367 2304
2328 2342 2282
2319 2292
2309 22732291 2256
2274 2240 2258 2226
2244 2213
2231 2223
2227 2211
2216 2205
2200 2196
2190 2187 2172
2181 2178
when greater deflection
than allowable #12 Screw Base Steel≥ ≥.25"
PAF Base Steel .0385" 2178 2163 2151 2150 2139 2129 2120
2311 2288 2267 2278 2259 2243 2228 2215 2202 2212 22012112 2105 2106 2099 2093
2190 2087
2181 2082 2077
2171 2163
PAF Base Steel ≥ 0.125"
Concrete + Deck = 2163 2150 2138 2137
45.0 psf Icr = 2127
55.4 in2118
/ft 2110 2102 2095 2096 2090 2084 2079 2074 2069
superimposed 4
Mno/Ω= 47.9 kip-in/ft Vn/Ω = 3.82 kip/ft
#12 Screw Base Steel ≥ (I .0385"
+I )/2 = 2149 2137
85.4 in /ft
4 2125 2126 2116 2107
I = 115.4 in /ft
4 2100 2092 2086 2088 2082
ϕM = 73.2 kip-in/ft 2076 ϕ2071
V = 2066 2062
5.73 kip/ft Factored
live load cr u u no n
Concrete + Deck = 44.0 psf Icr = 39.2 in4/ft Mno/Ω= 31.6 kip-in/ft Vn/Ω = 3.30 kip/ft diaphragm shear
Vertical Load Span(I(in)
+I )/2 = 8'-0"
73.2 in8'-6"
/ft 9'-0" 9'-6"
Iu = 10'-0"
107.1 in10'-6"
/ft 11'-0" 11'-6" ϕM
12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
cr u
4 4
no
= 48.4 kip-in/ft ϕ Vn = 4.76 kip/ft corresponding to
ASD & LRFD - Superimposed Load, W (psf) type of fastener
ASD, W/Ω 546 480 424 377 337 303 273 247 224 204 186 170 155 142 129
Attachment LRFD, ϕW 874 768 679 604 540 484 436 395 358 326 297 271 248 228 209

N PANELS
pattern for L/360 - - - - - - - - - - - - - 142 129 Allowable
weld, PAFs of LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern factored vertical
screws 16
Arc Spot Weld 1/2" Effective Dia 2898 2840 2788 2786 2742 2702 2666 2633 2602 2609 2581 2556 2533 2511 2491 shear of deck
PAF Base Steel ≥ .25" 2477 2443 2413 2431 2405 2381 2359 2339 2321 2339 2322 2307 2292 2279 2266 slab
PAF Base Steel ≥ 0.125" 2431 2400 2372 2393 2368 2346 2326 2308 2291 2310 2294 2279 2266 2253 2242
#12 Screw Base Steel ≥ .0385" 2431 2400 2373 2393 2369 2346 2326 2308 2291 2310 2294 2280 2266 2254 2242
Concrete + Deck = 45.7 psf Icr = 64.9 in4/ft Mno/Ω= 58.3 kip-in/ft Vn/Ω = 3.82 kip/ft Allowable
(Icr+Iu)/2 = 92.8 in4/ft Iu = 120.7 in4/ft ϕMno= 89.2 kip-in/ft ϕ Vn = 5.73 kip/ft
factored
momentum of
Attachment LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width deck slab
type to

C PANELS
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
supports 3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3200 4550 5540 7340 10040 Welded Wire
Weight of 24 in o.c. 3200 4550 5540 7340 7750 reinforcing
deck-slab 36 in o.c. 3200 4550 5170 5170 5170 required to
develop shear
when studs are
Spacing of used
shear studs Factored
Combined Cracked &
when used diaphragm
moment of uncracked shear when
D PANEL

Minimum area of
inertia of moment of studs are 60ksi reinforcing
deck-slab inertia of used on as an alternative
deck-slab collectors to WWF

Figure 1.12.1: SAMPLE OF COMPOSITE DECK TABLE


ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 39


TABLE OF CONTENTS

1.13 Support Fastening

Support Fastening
A variety of fastening systems may be used to connect steel Arc spot and arc seam welds do not have a mandatory
deck to the supporting steel members. The type of fastening minimum support member thickness. Experience has
system used depends on the required diaphragm shear shown that a support thickness as thin as 10 gage is
capacity, uplift capacity, and the thickness of the supporting reasonable. Welders with light gage welding experience
steel members. These fastening systems include arc spot can weld steel deck to thinner gage supports.
welds, arc seam welds, headed stud anchors, self-drilling
screws, and power-actuated fasteners (PAF). The strength of Steel headed stud anchors are subject to a minimum
each fastener type is mathematically derived from specified support member thickness in accordance with AISC 360.
standards and testing. This requires that the headed stud anchor be a minimum
of 2.5 times the thickness of the supporting beam flange
The shear strength for arc spot and arc seam welds is derived unless the headed studs anchor is placed directly over
from the equations in Section E2.6 of AISI S100-2012. The the web. For ¾” diameter stud, the minimum flange
strength for self-drilling screws and PAF is determined in thickness when the stud is not directly over the web is
accordance with the Steel Deck Institute Diaphragm Design 0.3 inches.
Manual DDM03. The strengths for these fasteners are listed
in the Weld and Shear Capacities Table (See figure 1.13.11 Self-drilling screws are suitable for use with supporting
and Figure 1.13.12). The shear strength of steel headed members from 0.0385 inches to ½”, depending on
stud anchors is determined in accordance with ASIC 360 thread pitch and drill point configuration. The fastener
Specification for Structural Steel Buildings. manufacturer should be consulted to determine which
screw is appropriate.
The pull-out and pull-over capacities for fasteners are in
accordance with Sections E4.4.1 and E4.4.2 of AISI S100- Power Actuated Fasteners (PAF) are selected based
2012. The pull-out for PAF’s should be obtained from the on a range of support thickness for a given fastener.
manufacturer’s data for the selected fastener. Follow the PAF manufacturer’s support thickness
recommendations. The fastener selection chart (See
Fastener Selection figure 1.13.1) provides a quick and easy guide to help
To ensure quality fastening to supports, the fastener select the appropriate fastening system for the support
(weld, screw, or PAF) must be compatible with the member thickness.
thickness of the steel support member. (See figure 1.13.1)

Figure 1.13.1: FASTENER SELECTION CHART Base Metal Thickness


Base Metal Thickness 0 1/8 1/4 3/8 1/2 5/8
Fastener Minimum Maximum
0.400" min when
3/4" ϕ Shear Stud unlimited
not over web

Arc Spot Weld* 0.135" unlimited

12-14 Self Drilling Screw** 0.0385" 0.210”

12-24 Self Drilling Screw** 0.125”* 0.500”

Hilti X-HSN-24 High Shear Nail 1/8” 3/8”

Hilti ENP19 L15 High Shear Nail 1/4” unlimited

Pneutek SDK61075 Fastener 0.113” 0.155”

Pneutex SDK63075 Fastener 0.155” 0.250”

Pneutek K64062 and K64075 Fastener 0.187” 0.312”

Pneutek K66062 and K66075 Fastener 0.312” unlimited

*Below 10 gage is not recommended due to the difficulty of producing a good quality weld. **Correct drill point must be selected for the base material thickness.

40 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Support Fastening 1.13

GENERAL INFORMATION
Minimum Fastener Edge Distance
The minimum edge distance for fasteners used with ASC Steel
Deck profiles has been verified through full-scale diaphragm
shear testing. The minimum edge distance for self-drilling
screws and PAFs is ½”. The minimum edge distance for arc
spot and arc seam welds is ¾”. Edge distance is measured

3W PANELS
from the center of the fastener or the center of the radius of an
arc spot or seam weld. (See figure 1.13.2)

End Lapped Deck Condition Butted Deck Condition

- 1/2”
2” + unlimitted Butted Tight or Gap
>emin >emin >emin >emin

2W PANELS
de
Figure 1.13.2: END LAP AND BUTTED DECK

Arc Spot and Arc Seam Welds


Traditionally, arc spot welds and arc seam welds are used to

B PANELS
attach steel deck to supports. (See figures 1.13.3 and 1.13.4) Figure 1.13.4: ARC SPOT WELD (weld to support)
Arc welds have high shear capacity, resulting in diaphragms
with higher shear capacities than screws or power actuated Welds used for composite deck-slab or non-composite
fasteners (PAF). deck-slab applications do not require touch up painting.
Specifications should not require the weld to receive
Welded connections have some drawbacks compared to touch-up paint for decks with concrete fill.
screws and PAF. Welds require skilled labor and have
a relatively slow production rate. Additionally, welding Arc spot and seam welds for ASC Steel Deck products
cannot be performed in the rain or if standing water is are specified based on the effective diameter or length

N PANELS
present on the deck. Welding often results in burn marks and width. This is approximately the diameter or width
visible from the underside of the deck and supporting and length of a weld at the interface between the deck
members, which may be objectionable for some exposed and supporting member. The effective weld size is less
deck conditions. Jobsite safety is of great concern as than the visible weld size and is verified through the
welding also creates a fire risk. development of weld qualifications and procedures.
See AISI S100-2012 Section E2 for more information
regarding weld design. Weld inspection, procedures, and
qualifications should be in accordance with AWS D1.3

C PANELS
Arc spot welds connecting deck less than 0.028 inches
thick require weld washers in accordance with AWS
D1.3. Weld washers are not recommended for thicker
decks. (See figure 1.13.5)
D PANEL

de

L
ACUSTADEK®

Figure 1.13.3: ARC SEAM WELD (weld to support) Figure 1.13.5: WELD WASHER

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 41


TABLE OF CONTENTS

1.13 Support Fastening

Power-Actuated Fasteners, PAF Hilti, Inc.


Power-actuated fasteners (PAF) are an excellent fastening Hilti, Inc.’s PAF system includes powder fired tools to install
system. Commonly referred to as high shear nails or pins, their high shear nails (HSN) and ENP fasteners. The operator
they can be used to achieve mid to high range diaphragm of the powder-fired tools must have OSHA compliant
shear capacities, depending on the fastener selected and safety training. Contact Hilti, Inc. for fastener installation
the support thickness. The benefits of using PAFs is that they instructions and for additional technical support relating
can be installed without skilled qualified welders, are efficient to their fastening systems. (See figure 1.13.7 and 1.13.8)
to install, do not pose a jobsite fire risk, and do not leave any www.us.hilti.com 800-879-8000
burn marks associated with welding. This makes PAFs an
attractive option for architecturally exposed steel deck. Hilti Inc. Fasteners
X-ENP-19 L15, X-HSN 24
A drawback of PAF systems is that it may be difficult
for the design engineer to select the fastener size X-EDN-19 THQ12
X-EDK-22 THQ12
when designing with open-web steel joists because
the thickness of the top chord may be unknown.
Good practice would be to design the diaphragm with hnvs = 3/16” - 3/8”
the minimum expected substrate steel thickness, and
indicate a range of acceptable fasteners based on Steel Deck Panel
the thickness of the supporting steel member. The
inspection process on the jobsite should be tasked with Structural Steel Member

ensuring that the correct fastener is used based on the


substrate thickness.

Pneutek X-ENP-19 L15


Pneutek’s PAF system uses a pneumatic actuated tool.
This system does not use a powder charge to drive
the fastener. Contact Pneutek for fastener installation
hnvs = 5/16” - 3/8”
instructions and for additional technical support relating
to their fastening systems. (See figure 1.13.6)
www.pneutek.com 800-431-8665 Steel Deck Panel

Pneutek Fasteners
SDK61075, SDK63075, K64062, K66075, K66056, K66062, K66075 Structural Steel Member

Figure 1.13.7: HILTI X-ENP-19

X-HSN 24
Pneutek Fastener
Head in Contact
Steel Deck Panel
hnvs = 5 — 9 mm

Structural
Steel Member Steel Deck Panel

Structural Steel Member

Figure 1.13.6: PNEUTEK K64062 Figure 1.13.8: HILTI X-HSN 24

42 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Support Fastening 1.13

GENERAL INFORMATION
Headed Stud Anchor Self-Drilling Screws
The headed shear stud anchor is a traditional method of Self-drilling screws are an excellent option for attaching
attaching metal deck to supporting steel beams. (See deck to thin-gage metal supporting members. (See figure
figure 1.13.9) Shear studs are commonly used to develop 1.13.10) Although diaphragms which are attached with
composite steel beams. Headed shear stud anchors are an screws tend to have a lower shear capacity than other

3W PANELS
excellent way of transferring diaphragm shear forces from support fastening systems, screws install quickly with
a collector beam into the composite deck-slab system. lower skilled labor and do not leave any burn marks on
Shear studs replace an arc spot weld, PAF, or screws on a the deck or supporting members. This makes them an
one to one basis. attractive option for architecturally exposed steel deck.
Self drilling screws may not be practical on heavier
structural steel support members because it can be time
consuming to drill through the steel deck panel into the
supporting member. When installed, the driven screw
penetrates both the steel deck panel and the supporting

2W PANELS
member; as a result, the screw points are visible from the
underside of the supporting structure.

B PANELS
N PANELS
Self-Drilling Screw
Steel Panel
Steel Support

C PANELS
Figure 1.13.10: #12-24R1-1/4 SCREW

Figure 1.13.9: HEADED STUD ANCHOR D PANEL


ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 43


TABLE OF CONTENTS

1.13 Support Fastening

Figure 1.13.11

Nominal Strength WELDING CAPACITIES


Arc Seam Weld
Arc Spot (puddle) Weld (3/8 in x 1 in effective
Deck Panel Gage (1/2 in effective diameter) width & length)
Shear (lbs) Tensile (lbs) Shear (lbs)
22 2416 2310 3873
20 3364 2755 4688
BH, NH
18 5701 3618 6344
16 7263 4463 8065
22 2323 2243 3752
21 2886 2541 4293
20 3212 2689 4565
2WH, 3WxH
19 4486 3200 5531
18 5525 3561 6231
16 7172 4408 7948
20/20 8608 5290 9851
20/18 8836 6019 11521
20/16 8836 6862 13392
18/20 8836 6078 11660
BHF, NHF 18/18 8836 6853 13376
18/16 8836 7850 15298
16/20 8836 6935 13534
16/18 8836 7850 15298
16/16 8836 8875 17271
20/20 8509 5229 9717
20/18 8836 5960 11383
20/16 8836 6788 13250
18/20 8836 6026 11537
2WHF, 3WxHF 18/18 8836 6788 13250
18/16 8836 7782 15168
16/20 8836 6870 13408
16/18 8836 7782 15168
16/16 8836 8805 17138
Safety and Resistance Factors for Welds
for Conditions other than Diaphragm Shear
Shear Tension
Ω Φ Ω Φ
Arc Spot Weld 2.80 0.55 2.50 0.60
Arc Spot Weld 3.05 0.50
Arc Spot Weld 2.55 0.60
Arc Spot Weld 2.20 0.70
Arc Seam Weld 2.55 0.60
Calculated in Accordance with AISI S100-2012

44 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Support Fastening 1.13

GENERAL INFORMATION
Figure 1.13.12

Nominal Strength MECHANICAL FASTENER CAPACITIES


Nominal Shear Strength (lbs)
Screws Hilti Pneutek

Supporting Framing Steel Min 0.0385 0.250 0.125 0.125 0.125 0.312 0.232 0.155

3W PANELS
Thickness (in) Max unlimited unlimited 0.375 0.375 0.250 unlimited 0.312 0.232

# 12, #14 Self Drill

X-EDNK22 THQ12
X-ENP-19 L15

SDK63075

SDK61075
X-HSN 24

K66062
K66075

K64062
K64075
Deck
Deck Profile
Gage

2W PANELS
22 1402 1624 1508 1508 1841 1735 1728 1546
20 1683 1938 1800 1800 2258 2216 1977 1833
BH, NH
18 2241 2549 2367 2367 3132 3009 2417 2378
16 2803 3149 2924 2924 4076 3686 2812 2896
22 1359 1577 1464 1464 1780 1655 1689 1502
21 1547 1787 1659 1659 2055 1993 1860 1695
20 1641 1891 1756 1756 2195 2149 1941 1790

B PANELS
2WH, 3WxH
19 1969 2253 2092 2092 2698 2642 2210 2116
18 2203 2508 2329 2329 3071 2960 2389 2342
16 2766 3109 2887 2887 4011 3644 2787 2862
20/20 3370 3737 3470 3470 5092 4294 3176 3386
20/18 3886 4258 3953 3953 6071 4800 3485 3804
20/16 4448 4810 4466 4466 7201 5314 3801 4229

N PANELS
18/20 3928 4300 3992 3992 6154 4840 3509 3837
BHF, NHF 18/18 4444 4806 4462 4462 7191 5310 3799 4225
18/16 5006 5342 4960 4960 8383 5793 4099 4619
16/20 4491 4851 4504 4504 7288 5351 3824 4259
16/18 5006 5342 4960 4960 8383 5793 4099 4619
16/16 5569 5862 5444 5444 9639 6251 4385 4982

C PANELS
20/20 3328 3694 3430 3430 5014 4250 3150 3350
20/18 3844 4215 3914 3914 5989 4760 3460 3770
20/16 4406 4769 4429 4429 7114 5277 3778 4198
18/20 3891 4262 3958 3958 6081 4804 3487 3807
2WHF, 3WxHF 18/18 4406 4769 4429 4429 7114 5277 3778 4198
18/16 4969 5307 4928 4928 8302 5762 4079 4594
16/20 4453 4815 4471 4471 7211 5318 3804 4232
D PANEL

16/18 4969 5307 4928 4928 8302 5762 4079 4594


16/16 5531 5828 5412 5412 9553 6221 4367 4958
Calculated in Accordance with the SDI DDM03
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 45


TABLE OF CONTENTS

1.14 Side Seam Fastening

Side Seam Attachment Triple Button Punch


The side seam attachment for composite floor deck has a The Triple Button Punch™ is the latest innovation in
small influence on diaphragm shear capacity, but is critical reliable side seam connections for standing seam side
for holding the seam together during the concrete pour. laps for composite steel deck. (See figure 1.14.2) For
The side seam attachment creates a positive connection, architecturally exposed deck, the Triple Button Punch
limiting differential movement between the sheets of deck system is the best option because there are no penetrating
under out-of-plane loads during concrete placement. The holes that can leak concrete, and no unsightly burn
common side seam attachment systems are the Triple marks typically associated with welded connections. This
Button Punch™, traditional button punch, top seam weld, connection is installed using ASC Steel Deck's DeltaGrip
and DeltaGrip® system for standing seam interlock side tool with the triple button punch die set. The triple button
seams. Self-drilling screws are used for nestable side punch is more effective than a traditional button punch
seams. The two common types of side seams are the because the three dimpled connections are tightly seated
standing seam interlock and the nestable side seam (See using the DeltaGrip pneumatic tool. The DelatGrip tool
figure 1.14.1). produces consistent, repeatable punches that are not
subject to operator fatigue or punch depth settings that
cause quality problems with traditional hand operated
button punch tools.

STANDING SEAM (ALL) NESTABLE (B & N)

STANDING SEAM SCREWABLE SIDELAP (2W)

Figure 1.14.1: STANDING SEAM AND NESTABLE DIAGRAM


Figure 1.14.2: TRIPLE BUTTON PUNCH

Traditional Button Punch


The traditional button punch attachment is used to connect
standing seam side seams by creating a single dimpled
clinch connection. (See figure 1.14.3) The quality of a button
punch which has been installed with a hand-operated tool
is dependent on the operator and the depth of the particular
punching tool. A “good” button punch should not become
disengaged when a person modestly jumps on the adjacent
sheet of deck.

SAMPLE BUTTON PUNCH TOOL Figure 1.14.3: BUTTON PUNCH SIDE LAPS

46 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Side Seam Fastening 1.14

GENERAL INFORMATION
Self-Drilling Screws Screwable Sidelap
Self-drilling screws are used to attach standing seam Self-drilling screws are used to attach standing seam
screwable sidelap steel deck. (See figure 1.14.4) Screws screwable sidelap composite deck. (See figure 1.14.6) The
can be easily installed with low-skill labor using screw guns screws can be easily installed with low-skill labor using
that are readily available. Screws do not leave burn marks screw guns that are readily available. The screws do not

3W PANELS
associated with welding, but the screw points do protrude leave burn marks associated with welding, but the screw
through the underside of the steel deck. As a result, screws points do protrude through the underside of the steel
may not be acceptable for some architecturally exposed deck. As a result, screws may not be acceptable for some
steel deck. architecturally exposed steel deck.

2W PANELS
B PANELS
Figure 1.14.4: SIDE SEAM SELF-DRILLING SCREW Figure 1.14.6: SIDE SEAM SELF-DRILLING SCREW
(Nestable Sidelap) (Screwable Sidelap)

Top Seam Weld DeltaGrip®


Top seam welds are the least desirable method to connect The DeltaGrip system was developed in 2003 to reduce
standing seam composite deck together. (See figure the installed costs of high shear roof deck diaphragms
1.14.5) The top seam welds are slow to install, require by eliminating the costly top seam weld. The DeltaGrip
skilled welders, and contribute very little to the strength of connection has also been proven to be an effective side
the composite deck system. Top seam welds connect the seam connection for composite steel deck, keeping the

N PANELS
standing seam deck side seams by welding the three layers deck from separating during concrete placement. This
of steel deck together. This is done after the hem is crimped revolutionary clinching system punches three triangular
using a hand or pneumatically operated crimping tool. Top tabs though the standing seam interlock side seam.
seam welding is a slow process requiring skilled welders, This interlock creates the equivalent strength of a time
leading to increased installation cost. The welding creates consuming top seam weld with the rapid action of
burn marks on the underside of the deck and occasional a pneumatically powered DeltaGrip tool. High-quality
burn-through holes. Top seam welds are not recommended DeltaGrip connections can be installed with low-skill
for architecturally exposed steel deck. Weld inspection, labor compared to the skilled welders required to make
procedures, and qualifications should be in accordance top seam welds.

C PANELS
with AWS D1.3.

D PANEL
ACUSTADEK®

Figure 1.14.5: TOP SEAM WELD Figure 1.14.7: DELTAGRIP PUNCH

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 47


TABLE OF CONTENTS

1.15 Edge Form

Edge Form
Edge form is an integral part of a composite or non- FLASHING THICKNESS BY GAGE
composite deck installation. The edge form provides Gage Base Steel Thickness
containment of the concrete at the perimeter of the
22 0.0290
composite deck-slab system and around openings. Edge
form also provides a screed at the edge to help maintain 20 0.0350
slab thickness. Edge forms may be manufactured from 18 0.0470
bent plate, cold-formed sheet steel, and hot roll steel 16 0.0590
angles or channels. ASC Steel Deck manufactures cold-
14 0.0700
formed sheet steel flashings used for edge forms and
other flashing conditions. Section 1.17 shows typical 12 0.1050
installation conditions for common flashing types. 10 0.1350
Figure 1.15.1
Edge Form Flashings
Galvanized steel edge form flashings are custom
manufactured by ASC Steel Deck to meet project
requirements. The flashings are formed from ASTM
A653 SS Grade 33 minimum galvanized steel sheets. ≥3⁄4" ≥3⁄4"
Flashings are available in most common structural shapes
in 7 gages. (See figures 1.15.1 and 1.15.2) The standard
length flashing is 10’-0”, shorter lengths available upon
request. The minimum width of any stiffener or flat cross MINIMUM FLAT WIDTH MINIMUM STIFFENER WIDTH
section is ¾”. For Hat and Channel shapes, the web width
must be at least ¾” wider than the flange width.

Design of Edge Form 1"


Edge forms may be rationally designed to support
concrete and construction loads using the methods in STRIP FILLER PLATE (10" Max)
the SDI Floor Deck Design Manual based on engineering
mechanics and confirmatory testing. The SDI edge form
table provided in figure 1.15.3 provides an easy to use
design aid without the need to detailed calculations for ≥3⁄4"
common edge form conditions.

ANGLE ANGLE WITH STIFFENER

ZEE

F F

≥F+3⁄4" ≥F+3⁄4"
HAT CHANNEL

Figure 1.15.2

48 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Edge Form1.15

GENERAL INFORMATION
Figure 1.15.3: Pour stop gage selection table, based on overhang and slab depth. (as published in ANSI/SDI C-2011)

Pour Stop Overhang


Slab
Depth 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" 12"

3W PANELS
4.00 20 20 20 20 18 18 16 14 12 12 12 10 10
4.25 20 20 20 18 18 16 16 14 12 12 12 10 10
4.50 20 20 20 18 18 16 16 14 12 12 12 10 10
4.75 20 20 18 18 16 16 14 14 12 12 10 10 10
5.00 20 20 18 18 16 16 14 14 12 12 10 10
5.25 20 18 18 16 16 14 14 12 12 12 10 10
5.50 20 18 18 16 16 14 14 12 12 12 10 10

2W PANELS
5.75 20 18 16 16 14 14 12 12 12 12 10 10
6.00 18 18 16 16 14 14 12 12 12 10 10 10
6.25 18 18 16 14 14 12 12 12 12 10 10
6.50 18 16 16 14 14 12 12 12 12 10 10
6.75 18 16 14 14 14 12 12 12 10 10 10
7.00 18 16 14 14 12 12 12 12 10 10 10
7.25 16 16 14 14 12 12 12 10 10 10
12

B PANELS
7.50 16 14 14 12 12 12 10 10 10
7.75 16 14 14 12 12 12 10 10 10 10
8.00 14 14 12 12 12 12 10 10 10
8.25 14 14 12 12 12 10 10 10 10
8.50 14 12 12 12 12 10 10 10
8.75 14 12 12 12 12 10 10 10
9.00 14 12 12 12 10 10 10

N PANELS
9.25 12 12 12 12 10 10 10
9.50 12 12 12 10 10 10
9.75 12 12 12 10 10 10 1/
2”
10.00 12 12 10 10 10 10
10.25 12 12 10 10 10
10.50 12 12 10 10 10 1” Fillet Welds @ 12” O.C.
10.75 12 10 10 10

C PANELS
11.00 12 10 10 10 Pour Slab
Stop Depth
11.25 12 10 10
11.50 10 10 10
11.75 10 10
Edge Form Detail
12.00 10 10

2”
D PANEL

The above Selection Table is based on the following criteria: Overhang


1. Normal weight concrete (150 pcf). FD14 Edge Form detail
2. Horizontal and vertical Deflection is limited to 1/4” maximum for concrete dead load
3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf.
4. Pour Stop Selection Table does not consider the effect of the performance, deflection, or rotation of the pour stop support which may
include both the supporting composite deck and/or the frame.
ACUSTADEK®

5. Vertical leg return lip is recommended for all types (gages).


6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only.
7. SDI reserves the right to change any information in this section without notice.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 49


TABLE OF CONTENTS

1.16 Accessories

ASC Steel Deck offers a variety of accessories to complement Profile Cut Neoprene Closures
our steel deck offer. These include flashings, sump pans, Neoprene closures may be used on the top and bottom
weld washers, profile cut top (small void) and bottom (large of the steel deck to reduce vapor, moisture, and air from
void) neoprene foam, and galvanized steel closures. infiltrating into the building roof or floor assembly. These
are die-cut from black closed cell neoprene foam. The
When accessories are called for in the specifications, foam is manufactured in accordance with ASTM D-1056
the location must be clearly shown on the structural and and passes the FM-VSS No. 302, UL 94HBF, and UL 94
architectural drawings. Specifications which call for the HF1 flammability tests.
use of profile cut closures where walls meet the metal deck
may lead to unnecessary construction costs if they are only Profile Cut Metal Closures
needed at exterior walls or specific interior locations. Metal closures may be used to control animal nesting
within the building structure. Metal closures may be used
B36 DECK NEOPRENE AND METAL CLOSURES in combination with neoprene closures. Metal closures
with calking can also be used to reduce noise infiltration
as part of an acoustically engineered system. The metal
closures are stamped out of minimum 22 gage galvanized
sheet steel.
B36 Large Neoprene

B36 Large Metal


2WH NEOPRENE AND METAL CLOSURES

Figure 1.16.1

N32 DECK NEOPRENE AND METAL CLOSURES 2W Neoprene

2W Metal

N32 Large Neoprene Figure 1.16.4

N32 Large Metal 3WxH NEOPRENE AND METAL CLOSURES

Figure 1.16.2
Weld Washers
14 gauge x 3⁄8” diameter hole for welded attachment of C1.4- 3WxH Neoprene
32. Variable Gauge x 3⁄8” diameter hole for welded attach-
ment of C0.9-32. Weld washers are for use with 26 and 24
gage C1.4-32 and C0.9-32 only. Do not use weld washers
Raised Edge Weld Washer
on 22 gage or heavier steel decks.
3WxH Metal

Figure 1.16.5
14 Gage x 3⁄8” dia.
hole for welded
attachment of
C1.4-32 (CF13⁄8) DEEP DECK NEOPRENE CLOSURES
1”
3/4” Weld Washer
Curved
14 gauge X 3/8” dia. hole for welded attachment of CF 7/8”.
RD39 Raised Edge Weld Washers

14 Gage x 3⁄8” dia.


hole for welded
attachment of
C0.9-32 (CF7⁄8) 4.5D Neoprene 6D Neoprene 7.5D Neoprene

Figure 1.16.3 Figure 1.16.6

50 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Typical Details 1.17

GENERAL INFORMATION
Details
Composite deck-slab systems are not complete without
edge form and flashings to contain the concrete during
the pour. These common details are an important
part of the system. Edge forms provide both concrete

3W PANELS
containment and establish one point of depth control for
the concrete.

2W PANELS
Minimum Welded Wire
or Cell Closure
Rebar when Specified Edge Form

eq
eq

B PANELS
Figure 1.17.1: TYPICAL PLACEMENT OF TEMPERATURE
& SHRINKAGE REINFORCEMENT

N PANELS
Figure 1.17.3: SINGLE PIECE EDGE FROM PERPENDICULAR
TO DECK ON WIDE FLANGE BEAM

Edge Form Edge Form

C PANELS
Cell Closure
D PANEL

Figure 1.17.2: SINGLE PIECE EDGE FROM PARALLEL Figure 1.17.4: TWO PIECE EDGE FORM WITH
TO DECK ON WIDE FLANGE BEAM DECK CANTILEVER ON WIDE FLANGE BEAM
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 51


TABLE OF CONTENTS

1.17 Typical Details

Field Cut Deck Z Closure

Figure 1.17.5: DECK PARALLEL TO WIDE FLANGE BEAM Figure 1.17.8: DECK PARALLEL TO WIDE FLANGE BEAM CUT
WITH ZEE FLASHING TO ACCOMMODATE DECK MODULE

Field Cut Deck Cell Closure

Figure 1.17.6: DECK PARALLEL TO WIDE FLANGE BEAM CUT Figure 1.17.9: DECK TRANSITION ON WIDE FLANGE BEAM
TO ACCOMMODATE DECK MODULE

Filler Plates or

Figure 1.17.7: DECK PARALLEL TO WIDE FLANGE Figure 1.17.10: DECK PERPENDICULAR TO
BEAM WITH FILLER PLATES WIDE FLANGE BEAM

52 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Typical Details 1.17

GENERAL INFORMATION
Edge Form Hat or Channel
Section

3W PANELS
2W PANELS
Figure 1.17.14: SINGLE PIECE EDGE FROM PARALLEL TO
DECK ON OPEN WEB JOIST GIRDER

Figure 1.17.11: CONCRETE OR CMU WALL LEGER Edge Form


DECK PERPENDICULAR

B PANELS
Cell Closure

N PANELS
Figure 1.17.15: TWO PIECE EDGE FORM WITH DECK
CANTILEVER ON WIDE FLANGE BEAM

C PANELS
Figure 1.17.12: CONCRETE OR CMU WALL LEGER
DECK PARALLEL

D PANEL

HAT SECTION
ONLY REQUIRED
AT GIRDERS THAT
ARE AXIAL COLLECTORS
ACUSTADEK®

FOR DIAPHRAGM

Figure 1.17.13: CONCRETE OR CMU WALL Figure 1.17.16: DECK ON OPEN WEB STEEL
WITH EMBED PERPENDICULAR JOISTS AND OPEN WEB STEEL JOIST GIRDER

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 53


TABLE OF CONTENTS

1.17 Typical Details

Column Flashings
Columns may require deck support angles depending on deflections during concrete placement. The Detail in
web support. Smaller columns often do not require deck Figure 1.17.18 is a common example of how deck may
support angles because there are no unsupported webs be supported when required. Using the thinnest support
as shown in Figure 1.17.17. Large columns will create a angles practical, when installed as shown, makes fitting
condition in which one or more webs are unsupported, as and attaching the deck easier.
shown in Figure 1.17.18. When the webs are unsupported,
deck support angles are required to limit localized

DECK NOT SHOWN DECK NOT SHOWN


FOR CLARITY FOR CLARITY
Deck
Support
Angles

Deck Support Deck Support


Not Required Required
When These Webs When These Webs
are Supported are Unsupported
by Beams by Beams

Deck
Support
Angles

Figure 1.17.17: COLUMN DETAIL NOT REQUIRING Figure 1.17.18: COLUMN DETAIL REQUIRING
DECK SUPPORT ANGLES DECK SUPPORT ANGLES

54 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Composite Deck-Slab 1.18

GENERAL INFORMATION
Tables General Requirements

General Notes
1. The general notes apply to the entire catalog. neutral axis of gross or effective section
2. Composite steel deck is manufactured from galvanized sg Minimum section modulus for gross
steel conforming to ASTM A653 SS grade 50 or bare section
steel conforming to ASTM A1008 SS grade 50. r radius of gyration

3W PANELS
3. The concrete slabs depth in the tables is measured for Ae Effective are for compression
the bottom of deck to the top of concrete. se- Negative effective section modulus
4. The vertical load span is the clear span between se+ Positive effective section modulus
supporting members. Ie+ Positive effective moment of inertia
5. Superimposed load is the load which can be applied to Ie- Negative effective moment of inertia
the composite deck in addition to the weight of the steel I+ Positive effective moment of inertia
deck and concrete. for determining deflection
6. No uniform service load, based on an L/360 deflection I- Negative effective moment of inertia
limit, is shown when the load is greater than the for determining deflection

2W PANELS
allowable superimposed load. 11. Definition of symbols for reactions
7. For composite steel deck assemblies which exceed the h Flat width of web
scope of the table, the performance may be determined R/Ω ASD available reaction capacity
in accordance with ANSI/SDI C-2011. at support based on web crippling
a. For 2WH-36 and 2WHF-36 the embossment ϕR LRFD available reaction capacity at
shape is Type 1 with an embossment factor, support based on web crippling
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 r bend radius of web/flange transition
b. For 3WxH-36 and 3WxHF-36 the embossment θ angle relative to the support of the web
shape is Type 2 with an embossment factor, 12. Definition for headed shear stud anchors

B PANELS
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 Qn Nominal shear capacity for one welded
c. For BH-36 and BHF-36 the embossment shape is headed shear studs anchor
Type 1 with an embossment factor, Qn/Ω ASD available shear capacity for one
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011 welded headed shear studs anchor
d. For NH-32 and NHF-32 the embossment shape is ϕQn LRFD available shear capacity for one
Type 2 with an embossment factor, welded headed shear studs anchor
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011
8. Load tables are based on non-cellular version of Deck as a form

N PANELS
profile. The addition of the pan (bottom plate) of 1. Shoring spans are based on the load combinations
cellular deck increases steel area and inherently and bending strength requirements of ANSI/SDI
increases the performance of the composite deck C-2011, which include the weight of the deck. The
assembly. Using non-cellular design values in tables loading includes the weight of the deck, concrete
is therefore conservative. and 20psf uniform construction load, or 150 lbs/
9. Definition of symbols for composite deck ft line load at mid span. In addition to the loads in
As Area of reinforcing steel accordance with ANSI/SDI C-2011, 3psf is added
Icr Cracked moment of inertia for normal weight concrete, and 2 psf is added for
Iu Un-cracked moment of inertia light weight concrete to account for pounding due

C PANELS
(Icr+Iu)/2 Moment of inertia for determining to deck deflection between supporting members.
deflection under service load 2. The theoretical deflection is limited to L/180, but
L Vertical load clear span not to exceed 3/4 inch for the weight of concrete
Mno/Ω ASD available flexural moment and steel deck only.
Vn/Ω ASD available vertical shear 3. Reactions at supports shall not be exceeded. The
ϕMno LRFD available flexural moment shoring span may be limited by the reactions at
ϕVn LRFD available vertical shear supports in some conditions. For support reactions
ϕSn LRFD available diaphragm shear exceeding the reaction tables, the reactions shall
D PANEL

PAF Power actuated fastener be based on the web crippling of the steel deck
W/Ω ASD available superimposed load capacity using the flat width (h), angle to support (θ) and
ϕW LRFD available superimposed load bend radius (r) presented in the reactions tables in
capacity accordance with the provisions of AISI S100-2012.
10. Definition of symbols for panel properties 4. Conditions exceeding the scope of the tables,
Ag Gross Area of steel deck such as cantilever spans, may be determined in
t Design base steel thickness of steel deck accordance with ANSI/SDI C-2011 and submitted
Fy Yield strength of steel to the building official for approval.
ACUSTADEK®

Fu Tensile strength of steel


Ig Moment of inertia of gross section
yb Distance form extreme bottom fiber to

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 55


TABLE OF CONTENTS

1.18 Composite Deck-Slab


Tables General Requirements

Concrete and minimum reinforcing ½-inch tolerance) is required. Overlaps


1. The minimum 28-day compressive strength for greater than 2-1/2 inches do not affect
structural concrete shall be 3,000 psi (20.68 MPa). diaphragm performance, but is more
The appropriate concrete density (normal weight or difficult to install.
structural lightweight) is indicated in the tables. ii. The minimum edge distance for self-
2. Minimum reinforcing may be provided by reinforcing drilling screws and power driven
steel, welded wire fabric, or fibers in accordance with fasteners (pins/nails) is ½ inch.
of the following: 5. The minimum edge distance for welds is ¾ inch
a. Minimum steel reinforcing shall be equal to measured from the center of the arc spot weld and
0.00075 times the area of the concrete above the center of the end radius of the arc seam weld.
the steel deck, but not less than 6 x 6 W1.4
x W1.4 welded wire fabric with a 60,000psi Butted Tight or Gap
minimum tensile strength complying with ASTM >emin >emin
A1064.
b. Concrete fibers in accordance with ANSI/SDI
C-2011 section 13.a.1 or 13.a.2.

Attachment of composite steel deck to supports


1. To develop the shear capacity in the tables, the deck
shall be attached to the supports with the specified
fastener pattern.
2. Spacing of welds or fasteners running parallel with the
deck shall not exceed 36 inches on center.
3. Power actuated fasteners shall be installed per Figure 1.18.1: BUTTED DECK CONDITION
manufacture's instructions
4. Welds and fasteners to the supports shall be as
2” +- 1/2”
unlimitted
follows:
a. Welds >emin >emin
i. Welds shall be have a minimum of 60ksi
filler metal. For shielded metal arc
welding, a minimum E60xx electrode
should be used.
ii. Arc spot welds shall have a minimum ½
inch effective diameter and not less than
a 5/8 inch visible diameter
iii. Arc seam welds shall have a minimum 3⁄8
inch x 1 inch effective size, and may be
substituted for ½ inch effective diameter Figure 1.18.2: END LAPPED DECK CONDITION
arc spot welds
b. Power actuated fasteners (PAF) in support steel Side seam attachment between deck panels
≥ .25 inch thick shall be: 1. The minimum side seam attachment is a button
i. Hilti X-ENP19 punch at 36 inches on center.
ii. Pneutek K64 2. Triple Button Punches, DeltaGrip side seam
iii. Pneutek K66 connections, arc top seam welds, or self-drilling
c. Power actuated fasteners (PAF) in support steel screws may be substituted on a one to one basis for
≥ 0.109 inch thick shall be: button punches.
i. Hilti X-HSN 24 3. The minimum edge distance for side lap screws is 1.5
ii. Pneutek K63 times the nominal diameter of the screw.
iii. Pneutek K61
d. Self-drilling screws in support steel ≥ .034 inch Diaphragm shear attached with arc spot welds,
thick shall be: power actuated fasteners, or self-drilling
i. #12 Self Drilling-Screw in accordance screws.
with SAE J78 1. For composite steel deck assemblies which exceed
e. Minimum Edge Distance the scope of the tables, the diaphragm shear
i. Steel deck may be butted at supports performance may be determined in accordance with
or end lapped. The standard end lap the SDI DDM03 referenced in ANSI/SDI C-2011
is a 2-inch overlap with a tolerance 2. Diaphragms with concrete fill have a flexibility factor, f
of +/-1/2 inch. The minimum 1-1/2 < 0.5 micro inches per lb equal to a shear stiffness, G’
inch overlap (2-inch standard less > 2000kip/inch

56 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Composite Deck-Slab 1.18

GENERAL INFORMATION
Tables General Requirements

3. Spacing of welds or fasteners transferring shear 3


⁄4" Steel Headed Stud Anchors
between the composite steel deck and supporting Shear Capacity1
structures shall be based on the shear demand and
the weld or fastener shear resistance. ASD LRFD
fastener spacing (ft) = weld or fastener capacity DECK TYPES Qn/R ϕQn

3W PANELS
(lbs) / shear demand (lbs/ft) 2WH-36, 2WHF-36, & 2WHF-36A,
10.3 kips 15.5 kips
4. Resistance and safety factors for diaphragm shear, 3WxH-36, 3WxHF-36, & 3WxHF-36A
ϕ = 0.5 BH-36, BHF-36, & BHF-36A
8.8 kips 13.2 kips
NH-32, NHF-32, & NHF-32A
Diaphragm shear with welded headed shear
stud anchors 145 pcf Normal Weight Concrete and 110 pcf Light Weight Concrete
1

1. Concrete shear reinforcing steel shall be provided Figure 1.18.3


that meets the minimum specified reinforcing
area, (As), in the table based on suggested welded Reinforcing Mesh

2W PANELS
or Bar
wire reinforcing size. Reinforcing shall have Reinforcing Mesh
or Bar
minimum yield strength of 60,000psi and meet the ≥½˝ Concrete
requirements of ACI 318 for standard reinforcing ≥1½˝
≥½˝ Thickness
Concrete
bars or WRI standard welded wire reinforcement.
≥1½˝ Thickness
Deck Height
2. To achieve tabulated diaphragm shears, the welded
stud shear connectors are only required at locations Deck Height
Shear Steel
in which diaphragm shear is being transferred Stud
Shear
Deck
Steel
between the composite deck slab and supporting Stud Deck
Deck Parallel to Beam
members. Intermediate support members may

B PANELS
Reinforcing Mesh
be attached with welds, screws or PAF’s (power or Bar
Reinforcing Mesh
actuated fasteners) or Bar
3. Intermediate ribs of the steel deck not attached with ≥½˝ Concrete
welded stud shear connectors shall be fastened to ≥1½˝
≥½˝ Thickness
Concrete
the supporting member with arc spot welds, self- ≥1½˝ Thickness
Deck Height
drilling screws, or power actuated fasteners. Deck Height
4. The welded stud shear connector strength assumes Shear Steel
the weak position in the deck flute. Reference AISC Stud Deck
Shear Steel

N PANELS
360-10 Commentary and Figure C-I8.1. Stud Deck
Deck May Extend
as Shown
5. Tabular values for shear strength of concrete Deck May Extend
diaphragm above deck is in accordance with ACI as Shown
318-14 based on a resistance factor ϕ = 0.75. Deck Perpendicular to Beam
Refer to ACI 318 for additional requirements to be
Figure 1.18.4
considered in seismic design.
6. Welded stud shear connectors shall extend 1½” above 12. For diaphragm shear of composite steel deck
the top of the steel deck and shall have a minimum assemblies attached with welded shear studs which
of ½” concrete cover above the top of the installed

C PANELS
exceed the scope of the tables, the diaphragm shear
connector. Reference AISC 360-10 Section I3.2c. may be determined in accordance with the provision
7. The supporting member flange shall not be less of ACI 318 and AISC 360 as follows.
than 0.3 inches thick unless the welded stud shear a. The diaphragm shear shall be the lesser of the
connector is welded over the web of the supporting capacity of the reinforced concrete and the
member. Reference AISC 360-10 Section I8.1. capacity of the welded shear studs to transfer
8. The maximum center-to-center spacing of welded the shear from the supporting member to the
stud shear connectors shall not exceed 8 times the reinforced concrete section.
depth of concrete above the deck or 36” per AISC b. Reinforced concrete shear shall be determined
D PANEL

360-10 Section I8.2d. in accordance with the requirements of ACI 318


9. Concrete reinforcement details shall be in using the concrete thickness above the steel
accordance with ACI318. deck.
10. For local shear transfer in the field of the c. The welded shear stud strength shall be
diaphragm, ¾ inch diameter welded stud shear determined in accordance with AISC 360.
connectors shall be determined in accordance with
AISC 360. The following shear capacities are for
2 inches of concrete cover above the steel deck
ACUSTADEK®

and may be used conservatively for all thicknesses


greater than 2 inches.
11. See figure 1.18.4 for typical details

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 57


TABLE OF CONTENTS
2.1 3WxH-36
4½"
12"

3"
36/4

4½"
36"
3WxH-36 Profile 36/4 Attachment Pattern
0.060
2 1
1 3/16

3Wx Series Embossment

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
22 1.70 0.0290 50 65 0.504 0.770 1.48 0.497 1.236
21 1.92 0.0330 50 65 0.556 0.850 1.48 0.548 1.236
20 2.09 0.0359 50 65 0.605 0.927 1.48 0.595 1.236
19 2.43 0.0420 50 65 0.708 1.083 1.48 0.695 1.236
18 2.76 0.0478 50 65 0.806 1.233 1.49 0.789 1.236
16 3.43 0.0598 50 65 1.008 1.540 1.49 0.984 1.236

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending
Distance to Distance to Uniform Load Only
Section N.A. from Section N.A. from Moment of Moment of
Gage Area Modulus Bottom Modulus Bottom Inertia Inertia Id = (2Ie+Ig)/3
Ae Se+ yb Se- yb Ie+ Ie - I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
22 0.309 0.392 1.33 0.404 1.63 0.727 0.720 0.741 0.737
21 0.362 0.452 1.36 0.465 1.61 0.823 0.813 0.832 0.826
20 0.414 0.510 1.39 0.524 1.59 0.910 0.900 0.916 0.909
19 0.532 0.636 1.43 0.654 1.55 1.083 1.073 1.083 1.077
18 0.651 0.761 1.46 0.781 1.52 1.233 1.230 1.233 1.231
16 0.887 0.984 1.49 0.982 1.50 1.540 1.540 1.540 1.540

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 6" 1" 2" 4" 6"
End 296 368 471 550 452 564 721 842
22
Interior 522 630 783 900 776 937 1164 1338
End 379 470 598 697 580 719 915 1066
21
Interior 667 801 990 1135 993 1191 1472 1688
End 424 524 666 775 649 802 1020 1186
20
Interior 746 893 1101 1261 1110 1329 1638 1876
End 600 737 930 1078 918 1127 1423 1650
19
Interior 1054 1252 1532 1747 1568 1863 2280 2599
End 743 908 1141 1320 1137 1389 1746 2020
18
Interior 1305 1542 1878 2136 1941 2294 2794 3178
End 1143 1383 1723 1983 1749 2116 2636 3034
16
Interior 2008 2350 2834 3206 2986 3495 4216 4768
Web Crippling Constraints h=2.16" r=0.125" θ=54.4º

58 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxHF-36 2.2

GENERAL INFORMATION
4½"
12"

3"
36/4

4½"
36" 36/4 Attachment Pattern
3WxHF-36 Profile

3W PANELS
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 3.69 0.035 / 0.036 50 65 1.054 1.542 0.91 0.712 1.209

2W PANELS
20/18 4.16 0.035 / 0.047 50 65 1.193 1.640 0.81 0.723 1.172
20/16 4.68 0.035 / 0.059 50 65 1.344 1.727 0.74 0.732 1.133
18/20 4.35 0.047 / 0.036 50 65 1.253 1.932 1.02 0.934 1.242
18/18 4.83 0.047 / 0.047 50 65 1.392 2.058 0.93 0.949 1.216
18/16 5.35 0.047 / 0.059 50 65 1.543 2.172 0.85 0.962 1.186
16/20 5.03 0.059 / 0.036 50 65 1.45 2.309 1.1 1.155 1.262
16/18 5.51 0.059 / 0.047 50 65 1.593 2.457 1.01 1.174 1.242
16/16 6.03 0.059 / 0.059 50 65 1.744 2.595 0.94 1.191 1.220

B PANELS
Effective Section Modulus at Fy
Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie + I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft

N PANELS
20/20 0.481 0.538 0.75 0.645 1.42 1.506 1.186 1.518 1.305
20/18 0.551 0.540 0.66 0.674 1.23 1.582 1.363 1.601 1.455
20/16 0.650 0.562 0.61 0.701 1.04 1.640 1.512 1.669 1.584
18/20 0.691 0.875 0.98 0.844 1.49 1.930 1.484 1.931 1.633
18/18 0.761 0.878 0.88 0.879 1.34 2.056 1.693 2.057 1.815
18/16 0.860 0.875 0.80 0.910 1.19 2.170 1.868 2.171 1.969
16/20 0.923 1.175 1.11 1.047 1.53 2.306 1.790 2.307 1.963
16/18 0.997 1.194 1.02 1.084 1.40 2.454 2.012 2.455 2.160

C PANELS
16/16 1.095 1.211 0.95 1.119 1.28 2.592 2.214 2.593 2.341

D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 59


TABLE OF CONTENTS

2.3 3WxHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

3WxHF-36 Cellular Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 45.9 12' - 2" 12' - 4" 13' - 0"
20/18 46.4 12' - 3" 12' - 10" 13' - 1"
20/16 46.9 12' - 3" 13' - 1" 13' - 0"
18/20 46.6 13' - 10" 13' - 8" 13' - 4"
1.080
5 18/18 47.0 14' - 1" 14' - 9" 13' - 4"
18/16 47.6 14' - 2" 15' - 0" 13' - 4"
16/20 47.2 14' - 6" 14' - 11" 13' - 4"
16/18 47.7 14' - 9" 16' - 3" 13' - 4"
16/16 48.2 14' - 10" 16' - 7" 13' - 4"
20/20 58.0 11' - 2" 11' - 4" 12' - 0"
20/18 58.5 11' - 3" 11' - 10" 12' - 1"
20/16 59.0 11' - 2" 12' - 1" 12' - 0"
18/20 58.7 13' - 2" 12' - 8" 13' - 4"
1.389
6 18/18 59.1 13' - 4" 13' - 7" 13' - 4"
18/16 59.7 13' - 5" 13' - 11" 13' - 4"
16/20 59.3 13' - 9" 13' - 10" 13' - 4"
16/18 59.8 13' - 11" 15' - 1" 13' - 4"
16/16 60.3 14' - 1" 15' - 4" 13' - 4"
20/20 64.0 10' - 9" 10' - 11" 11' - 7"
20/18 64.5 10' - 9" 11' - 5" 11' - 8"
20/16 65.0 10' - 9" 11' - 8" 11' - 7"
6 1/2
18/20 64.7 12' - 10" 12' - 2" 13' - 4"
1.543
18/18 65.2 13' - 0" 13' - 2" 13' - 4"
1 Hour
18/16 65.7 13' - 2" 13' - 5" 13' - 4"
Fire Rating
16/20 65.4 13' - 5" 13' - 4" 13' - 4"
16/18 65.8 13' - 8" 14' - 6" 13' - 4"
16/16 66.4 13' - 9" 14' - 10" 13' - 4"
20/20 76.1 10' - 0" 10' - 3" 10' - 10"
20/18 76.6 10' - 1" 10' - 8" 10' - 11"
20/16 77.1 10' - 1" 10' - 11" 10' - 11"
7 1/2
18/20 76.8 12' - 4" 11' - 5" 13' - 3"
1.852
18/18 77.3 12' - 6" 12' - 4" 13' - 4"
2 Hour
18/16 77.8 12' - 8" 12' - 7" 13' - 4"
Fire Rating
16/20 77.5 12' - 11" 12' - 6" 13' - 4"
16/18 77.9 13' - 1" 13' - 8" 13' - 4"
16/16 78.4 13' - 3" 13' - 11" 13' - 4"
20/20 85.2 9' - 7" 9' - 10" 10' - 5"
20/18 85.7 9' - 7" 10' - 3" 10' - 5"
20/16 86.2 9' - 7" 10' - 5" 10' - 5"
8 1/4
18/20 85.8 12' - 0" 10' - 11" 12' - 8"
2.083 18/18 86.3 12' - 1" 11' - 10" 12' - 9"
3 Hour
18/16 86.8 12' - 2" 12' - 0" 12' - 10"
Fire Rating
16/20 86.5 12' - 7" 12' - 0" 13' - 4"
16/18 87.0 12' - 9" 13' - 1" 13' - 4"
16/16 87.5 12' - 11" 13' - 4" 13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

60 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxHF-36 Cellular Composite Deck 2.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
3WxHF-36 Cellular Shoring Table
110 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 35.7 13' - 6" 13' - 5" 14' - 3"
20/18 36.2 13' - 7" 14' - 0" 14' - 3"
20/16 36.7 13' - 6" 14' - 3" 14' - 3"
18/20 36.4 14' - 9" 15' - 0" 14' - 3"

2W PANELS
5 1.080 18/18 36.8 15' - 0" 16' - 1" 14' - 3"
18/16 37.4 15' - 1" 16' - 5" 14' - 3"
16/20 37.0 15' - 6" 16' - 4" 14' - 3"
16/18 37.5 15' - 8" 17' - 10" 14' - 3"
16/16 38.0 15' - 10" 18' - 2" 14' - 3"
20/20 40.3 12' - 11" 12' - 11" 13' - 8"
20/18 40.8 13' - 0" 13' - 6" 13' - 9"
20/16 41.3 12' - 11" 13' - 9" 13' - 8"
5 1/2

B PANELS
18/20 40.9 14' - 4" 14' - 5" 14' - 3"
1.235 18/18 41.4 14' - 7" 15' - 6" 14' - 3"
1 Hour
18/16 41.9 14' - 8" 15' - 9" 14' - 3"
Fire Rating
16/20 41.6 15' - 0" 15' - 8" 14' - 3"
16/18 42.1 15' - 3" 17' - 1" 14' - 3"
16/16 42.6 15' - 5" 17' - 5" 14' - 3"
20/20 44.9 12' - 5" 12' - 6" 13' - 2"
20/18 45.4 12' - 6" 13' - 0" 13' - 3"

N PANELS
20/16 45.9 12' - 5" 13' - 3" 13' - 3"
18/20 45.5 14' - 0" 13' - 11" 14' - 3"
6 1.389 18/18 46.0 14' - 2" 14' - 11" 14' - 3"
18/16 46.5 14' - 4" 15' - 3" 14' - 3"
16/20 46.2 14' - 8" 15' - 2" 14' - 3"
16/18 46.7 14' - 10" 16' - 6" 14' - 3"
16/16 47.2 15' - 0" 16' - 10" 14' - 3"
20/20 47.2 12' - 2" 12' - 3" 13' - 0"

C PANELS
20/18 47.6 12' - 3" 12' - 9" 13' - 1"
20/16 48.2 12' - 2" 13' - 0" 13' - 0"
6 1/4
18/20 47.8 13' - 10" 13' - 8" 14' - 3"
1.466 18/18 48.3 14' - 0" 14' - 8" 14' - 3"
2 Hour
18/16 48.8 14' - 2" 15' - 0" 14' - 3"
Fire Rating
16/20 48.5 14' - 6" 14' - 11" 14' - 3"
16/18 49.0 14' - 8" 16' - 3" 14' - 3"
16/16 49.5 14' - 10" 16' - 7" 14' - 3"
20/20 55.8 11' - 5" 11' - 7" 12' - 3"
D PANEL

20/18 56.2 11' - 6" 12' - 1" 12' - 4"


20/16 56.8 11' - 5" 12' - 4" 12' - 3"
7 3/16
18/20 56.4 13' - 4" 12' - 11" 14' - 3"
1.755 18/18 56.9 13' - 6" 13' - 11" 14' - 3"
3 Hour
18/16 57.4 13' - 8" 14' - 2" 14' - 3"
Fire Rating
16/20 57.1 13' - 11" 14' - 1" 14' - 3"
16/18 57.6 14' - 2" 15' - 4" 14' - 3"
ACUSTADEK®

16/16 58.1 14' - 4" 15' - 8" 14' - 3"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 61


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.080yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 10' - 1" 11' - 0" 11' - 4" 19 12' - 3" 13' - 10" 14' - 4"
21 11' - 0" 11' - 9" 12' - 2" 18 12' - 7" 15' - 2" 14' - 9"
20 11' - 9" 12' - 6" 12' - 11" 16 13' - 3" 16' - 7" 15' - 7"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 282 246 216 190 169 150 134 119 107 96 86 78 70 63 57
LRFD, ϕW 451 394 345 304 270 240 214 191 171 154 138 124 112 101 90
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2367 2342 2319 2309 2291 2274 2258 2244 2231 2227 2216 2205 2196 2187 2178
PAF Base Steel ≥ .25" 2178 2163 2151 2150 2139 2129 2120 2112 2105 2106 2099 2093 2087 2082 2077
PAF Base Steel ≥ 0.125" 2163 2150 2138 2137 2127 2118 2110 2102 2095 2096 2090 2084 2079 2074 2069
#12 Screw Base Steel ≥ .0385" 2149 2137 2125 2126 2116 2107 2100 2092 2086 2088 2082 2076 2071 2066 2062
Concrete + Deck = 44.0 psf Icr = 39.2 in4/ft Mno/Ω= 31.6 kip-in/ft Vn/Ω = 3.30 kip/ft
(Icr+Iu)/2 = 73.2 in4/ft Iu = 107.1 in4/ft ϕMno= 48.4 kip-in/ft ϕ Vn = 4.76 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 311 272 239 211 187 167 149 133 120 108 97 88 79 72 65
LRFD, ϕW 498 435 382 337 299 266 238 213 192 172 155 140 127 114 103
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2430 2401 2375 2365 2343 2324 2306 2289 2274 2271 2258 2246 2234 2224 2214
PAF Base Steel ≥ .25" 2213 2196 2181 2182 2169 2158 2147 2138 2129 2132 2124 2117 2110 2104 2098
PAF Base Steel ≥ 0.125" 2196 2180 2166 2168 2156 2145 2135 2126 2118 2121 2113 2107 2100 2094 2089
#12 Screw Base Steel ≥ .0385" 2181 2166 2153 2155 2144 2134 2124 2116 2108 2111 2104 2098 2092 2086 2081
Concrete + Deck = 44.3 psf Icr = 42.3 in4/ft Mno/Ω= 34.6 kip-in/ft Vn/Ω = 3.82 kip/ft
(Icr+Iu)/2 = 75.4 in4/ft Iu = 108.6 in4/ft ϕMno= 52.9 kip-in/ft ϕ Vn = 5.66 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 338 296 260 230 204 182 163 147 132 119 107 97 88 80 72
LRFD, ϕW 541 473 416 368 327 292 261 234 211 190 172 155 141 128 116
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2477 2445 2416 2407 2383 2361 2341 2323 2307 2304 2289 2276 2263 2252 2241
PAF Base Steel ≥ .25" 2239 2220 2204 2206 2192 2179 2168 2157 2147 2151 2142 2134 2127 2120 2114
PAF Base Steel ≥ 0.125" 2220 2203 2188 2190 2177 2165 2154 2144 2135 2139 2131 2124 2117 2110 2104
#12 Screw Base Steel ≥ .0385" 2205 2189 2174 2177 2165 2153 2143 2134 2125 2130 2122 2115 2108 2102 2096
Concrete + Deck = 44.4 psf Icr = 45.1 in4/ft Mno/Ω= 37.3 kip-in/ft Vn/Ω = 3.82 kip/ft
(Icr+Iu)/2 = 77.5 in4/ft Iu = 110.0 in4/ft ϕMno= 57.1 kip-in/ft ϕ Vn = 5.73 kip/ft

62 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.080yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 394 345 304 270 240 215 192 173 156 141 128 116 106 97 88
LRFD, ϕW 630 552 487 431 384 343 308 277 250 226 205 186 170 154 141
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2579 2540 2506 2497 2468 2442 2418 2397 2377 2376 2358 2342 2327 2313 2300
PAF Base Steel ≥ .25" 2295 2273 2254 2258 2241 2226 2212 2200 2188 2194 2184 2174 2165 2156 2149
PAF Base Steel ≥ 0.125" 2274 2253 2235 2241 2225 2210 2197 2185 2174 2181 2171 2161 2153 2145 2137
#12 Screw Base Steel ≥ .0385" 2258 2238 2220 2227 2212 2198 2185 2174 2163 2170 2161 2152 2144 2136 2129
Concrete + Deck = 44.8 psf Icr = 50.6 in4/ft Mno/Ω= 42.9 kip-in/ft Vn/Ω = 3.82 kip/ft
(Icr+Iu)/2 = 81.7 in4/ft Iu = 112.8 in4/ft ϕMno= 65.7 kip-in/ft ϕ Vn = 5.73 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 443 389 343 304 271 243 218 197 178 162 147 134 122 111 102
LRFD, ϕW 709 622 549 487 434 389 349 315 285 258 235 214 195 178 163
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2679 2634 2594 2587 2554 2523 2496 2470 2447 2448 2427 2408 2391 2374 2359
PAF Base Steel ≥ .25" 2352 2326 2303 2312 2292 2274 2258 2243 2229 2238 2226 2214 2204 2194 2184

N PANELS
PAF Base Steel ≥ 0.125" 2328 2304 2282 2292 2273 2256 2240 2226 2213 2223 2211 2200 2190 2181 2172
#12 Screw Base Steel ≥ .0385" 2311 2288 2267 2278 2259 2243 2228 2215 2202 2212 2201 2190 2181 2171 2163
Concrete + Deck = 45.0 psf Icr = 55.4 in4/ft Mno/Ω= 47.9 kip-in/ft Vn/Ω = 3.82 kip/ft
(Icr+Iu)/2 = 85.4 in4/ft Iu = 115.4 in4/ft ϕMno= 73.2 kip-in/ft ϕ Vn = 5.73 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 546 480 424 377 337 303 273 247 224 204 186 170 155 142 129

C PANELS
LRFD, ϕW 874 768 679 604 540 484 436 395 358 326 297 271 248 228 209
L/360 - - - - - - - - - - - - - 142 129
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2898 2840 2788 2786 2742 2702 2666 2633 2602 2609 2581 2556 2533 2511 2491
PAF Base Steel ≥ .25" 2477 2443 2413 2431 2405 2381 2359 2339 2321 2339 2322 2307 2292 2279 2266
PAF Base Steel ≥ 0.125" 2431 2400 2372 2393 2368 2346 2326 2308 2291 2310 2294 2279 2266 2253 2242
#12 Screw Base Steel ≥ .0385" 2431 2400 2373 2393 2369 2346 2326 2308 2291 2310 2294 2280 2266 2254 2242
D PANEL

Concrete + Deck = 45.7 psf Icr = 64.9 in4/ft Mno/Ω= 58.3 kip-in/ft Vn/Ω = 3.82 kip/ft
(Icr+Iu)/2 = 92.8 in4/ft Iu = 120.7 in4/ft ϕMno= 89.2 kip-in/ft ϕ Vn = 5.73 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3200 4550 5540 7340 10040
ACUSTADEK®

24 in o.c. 3200 4550 5540 7340 7750


36 in o.c. 3200 4550 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 63


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.389yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 9' - 3" 10' - 1" 10' - 5" 19 11' - 7" 12' - 9" 13' - 3"
21 10' - 1" 10' - 10" 11' - 2" 18 11' - 11" 13' - 11" 14' - 0"
20 10' - 10" 11' - 6" 11' - 10" 16 12' - 7" 15' - 7" 14' - 9"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 380 331 291 257 228 203 181 162 145 131 118 106 96 86 78
LRFD, ϕW 607 530 466 411 364 324 289 259 232 209 188 170 153 138 125
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3348 3323 3300 3290 3271 3254 3239 3225 3212 3208 3197 3186 3177 3168 3159
PAF Base Steel ≥ .25" 3159 3144 3132 3131 3120 3110 3101 3093 3086 3087 3080 3074 3068 3063 3058
PAF Base Steel ≥ 0.125" 3144 3130 3118 3118 3108 3099 3090 3083 3076 3077 3071 3065 3060 3055 3050
#12 Screw Base Steel ≥ .0385" 3130 3117 3106 3107 3097 3088 3080 3073 3067 3069 3063 3057 3052 3047 3043
Concrete + Deck = 56.1 psf Icr = 63.6 in4/ft Mno/Ω= 42.3 kip-in/ft Vn/Ω = 3.85 kip/ft
(Icr+Iu)/2 = 123 in4/ft Iu = 182.5 in4/ft ϕMno= 64.8 kip-in/ft ϕ Vn = 5.57 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 419 366 322 285 253 225 202 181 163 147 132 120 108 98 89
LRFD, ϕW 670 586 515 455 404 360 322 289 260 234 212 191 173 157 142
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3411 3382 3356 3346 3324 3304 3286 3270 3255 3252 3239 3226 3215 3205 3195
PAF Base Steel ≥ .25" 3193 3177 3162 3162 3150 3138 3128 3119 3110 3112 3105 3097 3091 3085 3079
PAF Base Steel ≥ 0.125" 3177 3161 3147 3148 3136 3126 3116 3107 3099 3102 3094 3088 3081 3075 3070
#12 Screw Base Steel ≥ .0385" 3162 3147 3134 3136 3125 3114 3105 3097 3089 3092 3085 3079 3073 3067 3062
Concrete + Deck = 56.4 psf Icr = 68.6 in4/ft Mno/Ω= 46.3 kip-in/ft Vn/Ω = 4.50 kip/ft
(Icr+Iu)/2 = 127 in4/ft Iu = 184.7 in4/ft ϕMno= 70.8 kip-in/ft ϕ Vn = 6.47 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 455 399 351 311 276 247 221 199 179 162 146 132 120 109 99
LRFD, ϕW 729 638 561 497 442 395 353 318 286 258 234 212 192 175 159
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3458 3426 3397 3387 3363 3342 3322 3304 3287 3285 3270 3257 3244 3233 3222
PAF Base Steel ≥ .25" 3219 3201 3185 3186 3172 3160 3148 3138 3128 3132 3123 3115 3108 3101 3094
PAF Base Steel ≥ 0.125" 3201 3184 3169 3171 3158 3146 3135 3125 3116 3120 3112 3104 3097 3091 3085
#12 Screw Base Steel ≥ .0385" 3186 3170 3155 3158 3146 3134 3124 3115 3106 3110 3103 3095 3089 3082 3077
Concrete + Deck = 56.5 psf Icr = 73.2 in4/ft Mno/Ω= 50.0 kip-in/ft Vn/Ω = 4.90 kip/ft
(Icr+Iu)/2 = 130 in4/ft Iu = 186.9 in4/ft ϕMno= 76.5 kip-in/ft ϕ Vn = 7.27 kip/ft

64 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
6" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.389yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 531 465 410 364 324 290 261 235 212 192 174 159 144 132 120
LRFD, ϕW 849 744 656 582 519 464 417 376 339 307 279 254 231 211 193
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 3560 3521 3486 3478 3449 3423 3399 3378 3358 3357 3339 3323 3308 3294 3281
PAF Base Steel ≥ .25" 3276 3254 3234 3239 3222 3207 3193 3180 3169 3175 3165 3155 3146 3137 3129
PAF Base Steel ≥ 0.125" 3255 3234 3216 3221 3205 3191 3178 3166 3155 3162 3152 3142 3134 3126 3118
#12 Screw Base Steel ≥ .0385" 3239 3219 3201 3208 3193 3179 3166 3155 3144 3151 3142 3133 3124 3117 3110
Concrete + Deck = 56.9 psf Icr = 82.3 in4/ft Mno/Ω= 57.6 kip-in/ft Vn/Ω = 4.90 kip/ft
(Icr+Iu)/2 = 137 in4/ft Iu = 191.2 in4/ft ϕMno= 88.1 kip-in/ft ϕ Vn = 7.35 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 598 524 463 411 367 329 296 267 242 219 200 182 166 152 139
LRFD, ϕW 956 839 741 658 587 526 473 427 387 351 320 291 266 243 223
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3660 3615 3575 3568 3534 3504 3476 3451 3428 3429 3408 3389 3372 3355 3340
PAF Base Steel ≥ .25" 3333 3307 3284 3292 3273 3255 3238 3223 3210 3219 3207 3195 3185 3175 3165

N PANELS
PAF Base Steel ≥ 0.125" 3309 3284 3263 3272 3254 3237 3221 3207 3194 3204 3192 3181 3171 3161 3153
#12 Screw Base Steel ≥ .0385" 3292 3269 3248 3258 3240 3224 3209 3195 3183 3193 3182 3171 3161 3152 3144
Concrete + Deck = 57.1 psf Icr = 90.2 in4/ft Mno/Ω= 64.3 kip-in/ft Vn/Ω = 4.90 kip/ft
(Icr+Iu)/2 = 143 in4/ft Iu = 195.2 in4/ft ϕMno= 98.4 kip-in/ft ϕ Vn = 7.35 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 737 648 573 510 456 410 369 334 304 276 252 231 212 194 179

C PANELS
LRFD, ϕW 1179 1037 917 816 730 656 591 535 486 442 404 369 338 311 286
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3879 3820 3768 3767 3723 3683 3647 3613 3583 3589 3562 3537 3514 3492 3472
PAF Base Steel ≥ .25" 3458 3424 3394 3412 3386 3362 3340 3320 3302 3320 3303 3287 3273 3260 3247
PAF Base Steel ≥ 0.125" 3412 3381 3353 3374 3349 3327 3307 3288 3272 3290 3275 3260 3247 3234 3223
#12 Screw Base Steel ≥ .0385" 3412 3381 3354 3374 3350 3327 3307 3289 3272 3291 3275 3261 3247 3235 3223
D PANEL

Concrete + Deck = 57.8 psf Icr = 105.8 in4/ft Mno/Ω= 78.4 kip-in/ft Vn/Ω = 4.90 kip/ft
(Icr+Iu)/2 = 155 in4/ft Iu = 203.3 in4/ft ϕMno= 119.9 kip-in/ft ϕ Vn = 7.35 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 4190 5540 6530 8330 11030
ACUSTADEK®

24 in o.c. 4190 5540 6530 7750 7750


36 in o.c. 4190 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 65


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


6 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.543yd3/100ft2
1 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 8' - 11" 9' - 9" 10' - 1" 19 11' - 3" 12' - 4" 12' - 9"
21 9' - 8" 10' - 5" 10' - 9" 18 11' - 8" 13' - 5" 13' - 8"
20 10' - 5" 11' - 1" 11' - 5" 16 12' - 3" 15' - 0" 14' - 5"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 432 377 331 293 259 231 206 185 166 149 134 121 110 99 89
LRFD, ϕW 691 603 530 468 415 370 330 296 265 239 215 194 175 158 143
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3839 3813 3790 3781 3762 3745 3729 3715 3702 3698 3687 3677 3667 3658 3649
PAF Base Steel ≥ .25" 3649 3635 3622 3621 3610 3600 3592 3583 3576 3577 3571 3564 3559 3553 3548
PAF Base Steel ≥ 0.125" 3634 3621 3609 3609 3598 3589 3581 3573 3566 3568 3561 3556 3550 3545 3541
#12 Screw Base Steel ≥ .0385" 3621 3608 3597 3597 3587 3579 3571 3564 3557 3559 3553 3548 3542 3538 3533
Concrete + Deck = 62.2 psf Icr = 78.7 in4/ft Mno/Ω= 48.0 kip-in/ft Vn/Ω = 4.14 kip/ft
(Icr+Iu)/2 = 155 in4/ft Iu = 231.1 in4/ft ϕMno= 73.5 kip-in/ft ϕ Vn = 6.01 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 476 417 366 324 288 257 230 206 186 167 151 137 124 112 102
LRFD, ϕW 762 666 586 519 461 411 368 330 297 268 242 219 198 180 163
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3902 3872 3846 3836 3815 3795 3777 3761 3746 3742 3729 3717 3706 3695 3685
PAF Base Steel ≥ .25" 3684 3667 3652 3653 3640 3629 3619 3609 3600 3603 3595 3588 3581 3575 3569
PAF Base Steel ≥ 0.125" 3667 3651 3638 3639 3627 3616 3606 3597 3589 3592 3585 3578 3572 3566 3560
#12 Screw Base Steel ≥ .0385" 3652 3638 3624 3626 3615 3605 3596 3587 3579 3583 3576 3569 3563 3558 3552
Concrete + Deck = 62.4 psf Icr = 84.9 in4/ft Mno/Ω= 52.5 kip-in/ft Vn/Ω = 4.80 kip/ft
(Icr+Iu)/2 = 159 in4/ft Iu = 233.8 in4/ft ϕMno= 80.3 kip-in/ft ϕ Vn = 6.91 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 518 454 400 354 315 281 252 227 204 185 167 152 138 125 114
LRFD, ϕW 829 726 639 566 504 450 403 362 327 295 267 242 220 200 182
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3949 3916 3887 3878 3854 3832 3812 3794 3778 3775 3760 3747 3735 3723 3712
PAF Base Steel ≥ .25" 3710 3691 3675 3677 3663 3650 3639 3628 3619 3622 3614 3606 3598 3591 3585
PAF Base Steel ≥ 0.125" 3692 3674 3659 3662 3648 3636 3626 3616 3607 3611 3602 3595 3588 3581 3575
#12 Screw Base Steel ≥ .0385" 3676 3660 3645 3649 3636 3625 3614 3605 3596 3601 3593 3586 3579 3573 3567
Concrete + Deck = 62.5 psf Icr = 90.6 in4/ft Mno/Ω= 56.7 kip-in/ft Vn/Ω = 5.38 kip/ft
(Icr+Iu)/2 = 163 in4/ft Iu = 236.4 in4/ft ϕMno= 86.8 kip-in/ft ϕ Vn = 7.71 kip/ft

66 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
6 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.543yd3/100ft2
2 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 604 530 467 415 369 331 297 268 242 219 199 181 165 151 138
LRFD, ϕW 966 847 748 663 591 529 475 429 387 351 319 290 265 242 221
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 4050 4011 3977 3968 3940 3913 3890 3868 3848 3847 3829 3813 3798 3784 3771
PAF Base Steel ≥ .25" 3767 3744 3725 3730 3713 3697 3684 3671 3659 3666 3655 3645 3636 3628 3620
PAF Base Steel ≥ 0.125" 3745 3725 3706 3712 3696 3681 3668 3656 3645 3652 3642 3633 3624 3616 3609
#12 Screw Base Steel ≥ .0385" 3729 3709 3692 3698 3683 3669 3656 3645 3634 3642 3632 3623 3615 3607 3600
Concrete + Deck = 63.0 psf Icr = 101.9 in4/ft Mno/Ω= 65.4 kip-in/ft Vn/Ω = 5.49 kip/ft
(Icr+Iu)/2 = 172 in4/ft Iu = 241.7 in4/ft ϕMno= 100.0 kip-in/ft ϕ Vn = 8.23 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 681 598 528 469 419 375 338 305 276 251 228 208 190 174 160
LRFD, ϕW 1089 956 845 750 670 600 540 488 442 401 365 333 305 279 256
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 4150 4105 4065 4059 4025 3994 3967 3942 3918 3919 3899 3880 3862 3846 3830
PAF Base Steel ≥ .25" 3823 3797 3774 3783 3763 3745 3729 3714 3700 3710 3697 3686 3675 3665 3656

N PANELS
PAF Base Steel ≥ 0.125" 3799 3775 3753 3763 3744 3727 3711 3697 3684 3694 3682 3672 3661 3652 3643
#12 Screw Base Steel ≥ .0385" 3783 3759 3739 3749 3731 3714 3699 3686 3673 3684 3672 3662 3652 3643 3634
Concrete + Deck = 63.2 psf Icr = 111.7 in4/ft Mno/Ω= 73.1 kip-in/ft Vn/Ω = 5.49 kip/ft
(Icr+Iu)/2 = 179 in4/ft Iu = 246.6 in4/ft ϕMno= 111.8 kip-in/ft ϕ Vn = 8.23 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 840 739 654 582 521 468 422 382 347 316 288 264 242 222 205

C PANELS
LRFD, ϕW 1345 1182 1046 931 833 748 675 611 555 505 462 422 387 356 328
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4369 4311 4259 4257 4213 4173 4137 4104 4073 4080 4053 4028 4004 3983 3962
PAF Base Steel ≥ .25" 3948 3914 3884 3903 3876 3852 3831 3811 3793 3810 3793 3778 3763 3750 3738
PAF Base Steel ≥ 0.125" 3902 3871 3844 3864 3840 3817 3797 3779 3762 3781 3765 3751 3737 3725 3713
#12 Screw Base Steel ≥ .0385" 3903 3872 3844 3864 3840 3818 3798 3779 3762 3781 3766 3751 3738 3725 3713
D PANEL

Concrete + Deck = 63.9 psf Icr = 131.2 in4/ft Mno/Ω= 89.2 kip-in/ft Vn/Ω = 5.49 kip/ft
(Icr+Iu)/2 = 194 in4/ft Iu = 256.4 in4/ft ϕMno= 136.4 kip-in/ft ϕ Vn = 8.23 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 6030 7020 8820 11520
ACUSTADEK®

24 in o.c. n/a 6030 7020 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 67


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


7 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.852yd3/100ft2
2 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 8' - 4" 9' - 1" 9' - 5" 19 10' - 8" 11' - 6" 11' - 11"
21 9' - 0" 9' - 9" 10' - 1" 18 11' - 2" 12' - 7" 13' - 0"
20 9' - 8" 10' - 4" 10' - 8" 16 11' - 9" 14' - 1" 13' - 10"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 540 472 415 367 326 290 260 233 209 188 170 154 139 126 114
LRFD, ϕW 864 756 664 587 521 464 415 372 335 301 272 246 222 201 182
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 4819 4794 4771 4762 4743 4726 4710 4696 4683 4679 4668 4658 4648 4639 4630
PAF Base Steel ≥ .25" 4630 4616 4603 4602 4591 4581 4572 4564 4557 4558 4551 4545 4540 4534 4529
PAF Base Steel ≥ 0.125" 4615 4602 4590 4590 4579 4570 4562 4554 4547 4549 4542 4537 4531 4526 4521
#12 Screw Base Steel ≥ .0385" 4601 4589 4577 4578 4568 4560 4552 4544 4538 4540 4534 4528 4523 4519 4514
Concrete + Deck = 74.2 psf Icr = 114.4 in4/ft Mno/Ω= 59.8 kip-in/ft Vn/Ω = 4.76 kip/ft
(Icr+Iu)/2 = 234 in4/ft Iu = 354.1 in4/ft ϕMno= 91.5 kip-in/ft ϕ Vn = 6.94 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 596 522 459 407 362 323 289 260 234 211 191 173 157 143 130
LRFD, ϕW 954 835 735 651 579 516 463 416 374 338 306 277 251 228 207
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 4883 4853 4827 4817 4795 4776 4758 4741 4726 4723 4710 4698 4686 4676 4666
PAF Base Steel ≥ .25" 4665 4648 4633 4634 4621 4610 4599 4590 4581 4584 4576 4569 4562 4556 4550
PAF Base Steel ≥ 0.125" 4648 4632 4618 4620 4608 4597 4587 4578 4570 4573 4566 4559 4552 4547 4541
#12 Screw Base Steel ≥ .0385" 4633 4618 4605 4607 4596 4586 4576 4568 4560 4564 4557 4550 4544 4538 4533
Concrete + Deck = 74.5 psf Icr = 123.6 in4/ft Mno/Ω= 65.5 kip-in/ft Vn/Ω = 5.42 kip/ft
(Icr+Iu)/2 = 241 in4/ft Iu = 358.0 in4/ft ϕMno= 100.2 kip-in/ft ϕ Vn = 7.84 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 649 568 501 444 395 353 317 285 257 233 211 192 174 159 145
LRFD, ϕW 1038 910 802 710 632 565 507 456 412 372 338 307 279 254 231
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 4929 4897 4868 4859 4835 4813 4793 4775 4759 4756 4741 4728 4715 4704 4693
PAF Base Steel ≥ .25" 4691 4672 4656 4658 4644 4631 4620 4609 4600 4603 4594 4586 4579 4572 4566
PAF Base Steel ≥ 0.125" 4673 4655 4640 4642 4629 4617 4606 4597 4587 4592 4583 4576 4569 4562 4556
#12 Screw Base Steel ≥ .0385" 4657 4641 4626 4630 4617 4606 4595 4586 4577 4582 4574 4567 4560 4554 4548
Concrete + Deck = 74.6 psf Icr = 132.0 in4/ft Mno/Ω= 70.8 kip-in/ft Vn/Ω = 6.01 kip/ft
(Icr+Iu)/2 = 247 in4/ft Iu = 361.6 in4/ft ϕMno= 108.3 kip-in/ft ϕ Vn = 8.64 kip/ft

68 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
7 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.852yd3/100ft2
2 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 757 664 586 521 464 416 374 337 305 277 252 229 209 191 175
LRFD, ϕW 1212 1063 938 833 743 666 598 540 488 443 403 367 335 306 280
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 5031 4992 4958 4949 4920 4894 4871 4849 4829 4828 4810 4794 4779 4765 4752
PAF Base Steel ≥ .25" 4747 4725 4706 4711 4694 4678 4664 4652 4640 4646 4636 4626 4617 4609 4601
PAF Base Steel ≥ 0.125" 4726 4706 4687 4693 4677 4662 4649 4637 4626 4633 4623 4614 4605 4597 4590
#12 Screw Base Steel ≥ .0385" 4710 4690 4673 4679 4664 4650 4637 4626 4615 4623 4613 4604 4596 4588 4581
Concrete + Deck = 75.1 psf Icr = 148.9 in4/ft Mno/Ω= 81.7 kip-in/ft Vn/Ω = 6.73 kip/ft
(Icr+Iu)/2 = 259 in4/ft Iu = 369.2 in4/ft ϕMno= 125.0 kip-in/ft ϕ Vn = 10.09 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 855 751 664 590 527 473 426 385 349 317 289 264 241 221 203
LRFD, ϕW 1368 1201 1062 944 843 756 681 615 558 507 462 422 386 354 324
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5131 5086 5046 5039 5006 4975 4948 4922 4899 4900 4879 4860 4843 4826 4811
PAF Base Steel ≥ .25" 4804 4778 4755 4764 4744 4726 4710 4695 4681 4690 4678 4667 4656 4646 4637

N PANELS
PAF Base Steel ≥ 0.125" 4780 4756 4734 4744 4725 4708 4692 4678 4665 4675 4663 4652 4642 4633 4624
#12 Screw Base Steel ≥ .0385" 4764 4740 4719 4730 4712 4695 4680 4667 4654 4665 4653 4643 4633 4624 4615
Concrete + Deck = 75.3 psf Icr = 163.5 in4/ft Mno/Ω= 91.5 kip-in/ft Vn/Ω = 6.73 kip/ft
(Icr+Iu)/2 = 270 in4/ft Iu = 376.2 in4/ft ϕMno= 140.0 kip-in/ft ϕ Vn = 10.09 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1057 930 823 733 656 590 532 482 438 399 365 334 307 282 260

C PANELS
LRFD, ϕW 1691 1488 1317 1173 1050 944 852 771 701 639 584 535 491 451 416
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 5350 5292 5240 5238 5194 5154 5118 5085 5054 5061 5034 5008 4985 4963 4943
PAF Base Steel ≥ .25" 4929 4895 4865 4883 4857 4833 4811 4792 4773 4791 4774 4759 4744 4731 4718
PAF Base Steel ≥ 0.125" 4883 4852 4824 4845 4820 4798 4778 4760 4743 4762 4746 4732 4718 4706 4694
#12 Screw Base Steel ≥ .0385" 4884 4852 4825 4845 4821 4799 4778 4760 4743 4762 4746 4732 4718 4706 4694
D PANEL

Concrete + Deck = 75.9 psf Icr = 192.5 in4/ft Mno/Ω= 111.8 kip-in/ft Vn/Ω = 6.73 kip/ft
(Icr+Iu)/2 = 291 in4/ft Iu = 390.2 in4/ft ϕMno= 171.1 kip-in/ft ϕ Vn = 10.09 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 7020 8010 9810 12510
ACUSTADEK®

24 in o.c. n/a 7020 7750 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 69


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


8 1⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 2.083yd3/100ft2
3 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 11" 8' - 9" 9' - 0" 19 10' - 3" 11' - 0" 11' - 5"
21 8' - 7" 9' - 4" 9' - 8" 18 10' - 9" 12' - 1" 12' - 5"
20 9' - 3" 9' - 11" 10' - 3" 16 11' - 5" 13' - 6" 13' - 5"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 625 546 480 425 377 336 301 270 243 219 198 179 162 147 133
LRFD, ϕW 999 874 769 680 604 538 481 432 389 350 316 286 259 235 213
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 5555 5530 5507 5497 5478 5461 5446 5432 5419 5415 5404 5393 5383 5374 5366
PAF Base Steel ≥ .25" 5366 5351 5338 5338 5327 5317 5308 5300 5293 5294 5287 5281 5275 5270 5265
PAF Base Steel ≥ 0.125" 5351 5337 5325 5325 5315 5306 5297 5290 5283 5284 5278 5272 5267 5262 5257
#12 Screw Base Steel ≥ .0385" 5337 5324 5313 5314 5304 5295 5287 5280 5274 5275 5270 5264 5259 5254 5250
Concrete + Deck = 83.3 psf Icr = 146.3 in4/ft Mno/Ω= 69.0 kip-in/ft Vn/Ω = 5.37 kip/ft
(Icr+Iu)/2 = 309 in4/ft Iu = 471.8 in4/ft ϕMno= 105.5 kip-in/ft ϕ Vn = 7.86 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 690 604 532 471 419 374 335 301 272 245 222 202 183 166 151
LRFD, ϕW 1104 966 851 753 670 599 536 482 435 393 356 322 293 266 242
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 5618 5589 5563 5553 5531 5511 5493 5477 5462 5459 5446 5433 5422 5412 5402
PAF Base Steel ≥ .25" 5400 5384 5369 5369 5357 5345 5335 5326 5317 5319 5312 5304 5298 5291 5286
PAF Base Steel ≥ 0.125" 5384 5368 5354 5355 5343 5333 5323 5314 5306 5309 5301 5294 5288 5282 5277
#12 Screw Base Steel ≥ .0385" 5369 5354 5341 5343 5332 5321 5312 5304 5296 5299 5292 5286 5280 5274 5269
Concrete + Deck = 83.6 psf Icr = 158.2 in4/ft Mno/Ω= 75.5 kip-in/ft Vn/Ω = 6.03 kip/ft
(Icr+Iu)/2 = 317 in4/ft Iu = 476.7 in4/ft ϕMno= 115.6 kip-in/ft ϕ Vn = 8.76 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 751 658 580 514 458 409 367 331 299 270 245 223 203 185 169
LRFD, ϕW 1201 1052 928 823 733 655 588 529 478 433 392 357 325 296 270
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 5665 5633 5604 5594 5570 5549 5529 5511 5494 5492 5477 5464 5451 5439 5429
PAF Base Steel ≥ .25" 5426 5408 5392 5393 5379 5367 5355 5345 5335 5339 5330 5322 5315 5308 5301
PAF Base Steel ≥ 0.125" 5408 5391 5376 5378 5365 5353 5342 5332 5323 5327 5319 5311 5304 5298 5292
#12 Screw Base Steel ≥ .0385" 5393 5376 5362 5365 5353 5341 5331 5322 5313 5317 5310 5302 5296 5289 5284
Concrete + Deck = 83.7 psf Icr = 169.0 in4/ft Mno/Ω= 81.7 kip-in/ft Vn/Ω = 6.62 kip/ft
(Icr+Iu)/2 = 325 in4/ft Iu = 481.3 in4/ft ϕMno= 124.9 kip-in/ft ϕ Vn = 9.56 kip/ft

70 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
8 1⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 2.083yd3/100ft2
3 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 876 769 679 603 538 482 434 392 355 322 293 267 244 223 204
LRFD, ϕW 1402 1231 1087 965 861 772 694 627 567 515 468 427 390 357 327
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 5767 5728 5693 5685 5656 5630 5606 5585 5565 5563 5546 5530 5515 5501 5488
PAF Base Steel ≥ .25" 5483 5461 5441 5446 5429 5414 5400 5387 5376 5382 5371 5362 5353 5344 5336
PAF Base Steel ≥ 0.125" 5462 5441 5423 5428 5412 5398 5385 5373 5362 5369 5359 5349 5341 5333 5325
#12 Screw Base Steel ≥ .0385" 5446 5426 5408 5415 5399 5386 5373 5361 5351 5358 5349 5340 5331 5324 5317
Concrete + Deck = 84.1 psf Icr = 190.9 in4/ft Mno/Ω= 94.3 kip-in/ft Vn/Ω = 7.69 kip/ft
(Icr+Iu)/2 = 341 in4/ft Iu = 490.8 in4/ft ϕMno= 144.3 kip-in/ft ϕ Vn = 11.01 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 991 870 769 684 611 549 494 447 405 368 336 307 281 258 237
LRFD, ϕW 1585 1392 1231 1095 978 878 791 715 648 589 537 491 449 412 378
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5867 5822 5782 5775 5741 5711 5683 5658 5635 5636 5615 5596 5578 5562 5547
PAF Base Steel ≥ .25" 5540 5514 5491 5499 5480 5462 5445 5430 5417 5426 5414 5402 5391 5382 5372

N PANELS
PAF Base Steel ≥ 0.125" 5516 5491 5470 5479 5460 5443 5428 5414 5401 5411 5399 5388 5378 5368 5359
#12 Screw Base Steel ≥ .0385" 5499 5476 5455 5465 5447 5431 5416 5402 5390 5400 5389 5378 5368 5359 5351
Concrete + Deck = 84.3 psf Icr = 210.0 in4/ft Mno/Ω= 105.8 kip-in/ft Vn/Ω = 7.95 kip/ft
(Icr+Iu)/2 = 355 in4/ft Iu = 499.7 in4/ft ϕMno= 161.9 kip-in/ft ϕ Vn = 11.93 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1226 1079 956 851 762 685 619 561 510 465 425 389 358 329 303

C PANELS
LRFD, ϕW 1962 1726 1529 1362 1219 1096 990 897 815 743 680 623 572 526 485
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 6086 6027 5975 5974 5930 5890 5854 5820 5790 5796 5769 5744 5721 5699 5679
PAF Base Steel ≥ .25" 5664 5631 5601 5619 5593 5569 5547 5527 5509 5527 5510 5494 5480 5467 5454
PAF Base Steel ≥ 0.125" 5619 5588 5560 5581 5556 5534 5514 5495 5479 5497 5482 5467 5454 5441 5430
#12 Screw Base Steel ≥ .0385" 5619 5588 5561 5581 5556 5534 5514 5496 5479 5498 5482 5468 5454 5442 5430
D PANEL

Concrete + Deck = 85.0 psf Icr = 247.7 in4/ft Mno/Ω= 129.5 kip-in/ft Vn/Ω = 7.95 kip/ft
(Icr+Iu)/2 = 383 in4/ft Iu = 517.6 in4/ft ϕMno= 198.2 kip-in/ft ϕ Vn = 11.93 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 7760 8750 10550 13250
ACUSTADEK®

24 in o.c. n/a 7750 7750 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 71


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.080yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 11' - 2" 12' - 0" 12' - 5" 19 13' - 1" 15' - 2" 15' - 3"
21 12' - 2" 12' - 10" 13' - 4" 18 13' - 6" 16' - 7" 15' - 9"
20 12' - 7" 13' - 8" 14' - 1" 16 14' - 2" 17' - 8" 16' - 7"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 276 242 213 189 168 150 134 121 109 98 89 81 73 66 60
LRFD, ϕW 442 387 341 302 268 240 215 193 174 157 142 129 117 106 97
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 1711 1686 1663 1654 1635 1618 1602 1588 1575 1571 1560 1550 1540 1531 1522
PAF Base Steel ≥ .25" 1522 1508 1495 1494 1483 1473 1464 1456 1449 1450 1443 1437 1432 1426 1421
PAF Base Steel ≥ 0.125" 1507 1494 1482 1482 1471 1462 1454 1446 1439 1441 1434 1429 1423 1418 1413
#12 Screw Base Steel ≥ .0385" 1493 1481 1469 1470 1460 1452 1444 1436 1430 1432 1426 1420 1415 1411 1406
Concrete + Deck = 33.8 psf Icr = 53.5 in4/ft Mno/Ω= 30.3 kip-in/ft Vn/Ω = 2.83 kip/ft
(Icr+Iu)/2 = 83.9 in4/ft Iu = 114.4 in4/ft ϕMno= 46.4 kip-in/ft ϕ Vn = 4.05 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 304 266 235 208 185 166 149 134 121 109 99 90 82 75 68
LRFD, ϕW 486 426 375 333 296 265 238 214 193 175 159 144 131 119 109
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 1776 1746 1720 1710 1689 1669 1651 1635 1620 1616 1603 1591 1580 1569 1559
PAF Base Steel ≥ .25" 1558 1541 1527 1527 1514 1503 1493 1483 1475 1477 1469 1462 1455 1449 1443
PAF Base Steel ≥ 0.125" 1541 1526 1512 1513 1501 1490 1481 1472 1463 1466 1459 1452 1446 1440 1434
#12 Screw Base Steel ≥ .0385" 1527 1512 1499 1501 1489 1479 1470 1461 1454 1457 1450 1443 1437 1432 1427
Concrete + Deck = 34.1 psf Icr = 57.4 in4/ft Mno/Ω= 33.1 kip-in/ft Vn/Ω = 2.86 kip/ft
(Icr+Iu)/2 = 87 in4/ft Iu = 116.5 in4/ft ϕMno= 50.6 kip-in/ft ϕ Vn = 4.94 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 329 289 255 226 202 180 162 146 132 120 109 99 90 82 75
LRFD, ϕW 527 462 408 362 322 289 259 234 211 192 174 158 144 132 121
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 1824 1791 1762 1753 1729 1707 1688 1669 1653 1650 1636 1622 1610 1598 1587
PAF Base Steel ≥ .25" 1585 1567 1550 1552 1538 1525 1514 1503 1494 1497 1489 1481 1473 1466 1460
PAF Base Steel ≥ 0.125" 1567 1550 1534 1537 1524 1512 1501 1491 1482 1486 1478 1470 1463 1456 1450
#12 Screw Base Steel ≥ .0385" 1552 1535 1521 1524 1511 1500 1490 1480 1472 1476 1468 1461 1454 1448 1442
Concrete + Deck = 34.2 psf Icr = 61.0 in4/ft Mno/Ω= 35.6 kip-in/ft Vn/Ω = 2.86 kip/ft
(Icr+Iu)/2 = 89.8 in4/ft Iu = 118.5 in4/ft ϕMno= 54.5 kip-in/ft ϕ Vn = 5.73 kip/ft

72 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
5" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.080yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 381 335 296 263 235 210 189 171 155 141 128 117 107 97 87
LRFD, ϕW 610 536 473 421 376 337 303 274 248 225 205 187 171 157 144
L/360 - - - - - - - - - - - - - 97 87
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 1927 1888 1854 1846 1817 1791 1767 1745 1725 1724 1707 1690 1675 1661 1648
PAF Base Steel ≥ .25" 1644 1622 1602 1607 1590 1575 1561 1548 1536 1543 1532 1522 1513 1505 1497
PAF Base Steel ≥ 0.125" 1623 1602 1583 1589 1573 1559 1545 1533 1522 1529 1519 1510 1501 1493 1486
#12 Screw Base Steel ≥ .0385" 1606 1587 1569 1575 1560 1546 1534 1522 1512 1519 1509 1500 1492 1484 1477
Concrete + Deck = 34.6 psf Icr = 68.1 in4/ft Mno/Ω= 40.9 kip-in/ft Vn/Ω = 2.86 kip/ft
(Icr+Iu)/2 = 95.3 in4/ft Iu = 122.6 in4/ft ϕMno= 62.6 kip-in/ft ϕ Vn = 5.73 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 427 375 332 295 264 237 214 193 175 158 141 126 113 101 92
LRFD, ϕW 683 601 531 472 422 379 342 309 280 255 233 213 195 179 164
L/360 - - - - - - - - - 158 141 126 113 101 92
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2029 1984 1945 1938 1904 1874 1846 1821 1798 1798 1778 1759 1741 1725 1709
PAF Base Steel ≥ .25" 1702 1676 1654 1662 1642 1624 1608 1593 1579 1589 1576 1565 1554 1544 1535

N PANELS
PAF Base Steel ≥ 0.125" 1678 1654 1632 1642 1623 1606 1591 1576 1563 1573 1562 1551 1540 1531 1522
#12 Screw Base Steel ≥ .0385" 1662 1638 1618 1628 1610 1593 1579 1565 1552 1563 1551 1541 1531 1522 1513
Concrete + Deck = 34.8 psf Icr = 74.1 in4/ft Mno/Ω= 45.5 kip-in/ft Vn/Ω = 2.86 kip/ft
(Icr+Iu)/2 = 100 in4/ft Iu = 126.2 in4/ft ϕMno= 69.6 kip-in/ft ϕ Vn = 5.73 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 523 460 408 363 325 292 255 223 196 174 155 138 124 111 101

C PANELS
LRFD, ϕW 837 736 652 581 520 468 423 383 348 318 290 266 245 225 208
L/360 - - - - - - 255 223 196 174 155 138 124 111 101
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2253 2194 2142 2141 2096 2056 2020 1987 1957 1963 1936 1911 1887 1866 1845
PAF Base Steel ≥ .25" 1831 1797 1767 1786 1759 1735 1714 1694 1676 1693 1676 1661 1647 1633 1621
PAF Base Steel ≥ 0.125" 1785 1754 1727 1747 1723 1700 1680 1662 1645 1664 1648 1634 1620 1608 1596
#12 Screw Base Steel ≥ .0385" 1786 1755 1727 1748 1723 1701 1681 1662 1645 1664 1649 1634 1621 1608 1596
D PANEL

Concrete + Deck = 35.5 psf Icr = 86.1 in4/ft Mno/Ω= 55.2 kip-in/ft Vn/Ω = 2.86 kip/ft
(Icr+Iu)/2 = 110 in4/ft Iu = 133.7 in4/ft ϕMno= 84.4 kip-in/ft ϕ Vn = 5.73 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 2720 4070 5060 6860 9560
ACUSTADEK®

24 in o.c. 2720 4070 5060 6860 7750


36 in o.c. 2720 4070 5060 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 73


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


5 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.235yd3/100ft2
1 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 10' - 8" 11' - 7" 11' - 11" 19 12' - 8" 14' - 7" 14' - 10"
21 11' - 8" 12' - 4" 12' - 9" 18 13' - 1" 15' - 11" 15' - 4"
20 12' - 2" 13' - 1" 13' - 7" 16 13' - 9" 17' - 2" 16' - 2"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 323 283 249 221 196 175 157 141 128 115 104 95 86 78 71
LRFD, ϕW 517 453 399 353 314 281 252 226 204 185 167 152 138 125 114
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2035 2010 1987 1978 1959 1942 1926 1912 1899 1895 1884 1874 1864 1855 1846
PAF Base Steel ≥ .25" 1846 1832 1819 1818 1807 1797 1788 1780 1773 1774 1767 1761 1756 1750 1745
PAF Base Steel ≥ 0.125" 1831 1818 1806 1806 1795 1786 1778 1770 1763 1765 1758 1753 1747 1742 1737
#12 Screw Base Steel ≥ .0385" 1817 1805 1793 1794 1784 1776 1768 1761 1754 1756 1750 1744 1739 1735 1730
Concrete + Deck = 38.4 psf Icr = 68.9 in4/ft Mno/Ω= 35.3 kip-in/ft Vn/Ω = 3.03 kip/ft
(Icr+Iu)/2 = 110 in4/ft Iu = 150.4 in4/ft ϕMno= 54.1 kip-in/ft ϕ Vn = 4.34 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 355 311 274 243 217 194 174 157 142 128 116 106 96 88 80
LRFD, ϕW 568 498 439 389 347 310 279 251 227 205 186 169 154 141 128
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2100 2070 2044 2035 2013 1993 1975 1959 1944 1940 1927 1915 1904 1893 1884
PAF Base Steel ≥ .25" 1882 1865 1851 1851 1839 1827 1817 1807 1799 1801 1793 1786 1779 1773 1767
PAF Base Steel ≥ 0.125" 1865 1850 1836 1837 1825 1814 1805 1796 1787 1790 1783 1776 1770 1764 1758
#12 Screw Base Steel ≥ .0385" 1851 1836 1823 1825 1813 1803 1794 1785 1778 1781 1774 1767 1761 1756 1751
Concrete + Deck = 38.7 psf Icr = 74.0 in4/ft Mno/Ω= 38.6 kip-in/ft Vn/Ω = 3.26 kip/ft
(Icr+Iu)/2 = 114 in4/ft Iu = 153.1 in4/ft ϕMno= 59.0 kip-in/ft ϕ Vn = 5.24 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 385 338 298 264 236 211 190 171 155 140 128 116 106 97 89
LRFD, ϕW 616 540 477 423 377 338 304 274 248 225 204 186 170 155 142
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2148 2115 2087 2077 2053 2031 2012 1994 1977 1974 1960 1946 1934 1922 1911
PAF Base Steel ≥ .25" 1909 1891 1874 1876 1862 1849 1838 1828 1818 1821 1813 1805 1797 1790 1784
PAF Base Steel ≥ 0.125" 1891 1874 1858 1861 1848 1836 1825 1815 1806 1810 1802 1794 1787 1780 1774
#12 Screw Base Steel ≥ .0385" 1876 1859 1845 1848 1835 1824 1814 1804 1796 1800 1792 1785 1778 1772 1766
Concrete + Deck = 38.8 psf Icr = 78.6 in4/ft Mno/Ω= 41.6 kip-in/ft Vn/Ω = 3.26 kip/ft
(Icr+Iu)/2 = 117 in4/ft Iu = 155.6 in4/ft ϕMno= 63.6 kip-in/ft ϕ Vn = 6.04 kip/ft

74 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
5 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.235yd3/100ft2
1 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 446 391 346 308 275 246 222 201 182 165 151 137 126 115 106
LRFD, ϕW 713 626 554 492 439 394 355 321 291 264 241 220 201 184 169
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2251 2213 2178 2170 2141 2115 2091 2069 2049 2048 2031 2014 1999 1985 1972
PAF Base Steel ≥ .25" 1968 1946 1926 1931 1914 1899 1885 1872 1860 1867 1856 1846 1837 1829 1821
PAF Base Steel ≥ 0.125" 1947 1926 1907 1913 1897 1883 1869 1857 1846 1853 1843 1834 1825 1817 1810
#12 Screw Base Steel ≥ .0385" 1930 1911 1893 1899 1884 1870 1858 1846 1836 1843 1833 1824 1816 1808 1801
Concrete + Deck = 39.2 psf Icr = 87.8 in4/ft Mno/Ω= 47.7 kip-in/ft Vn/Ω = 3.26 kip/ft
(Icr+Iu)/2 = 124 in4/ft Iu = 160.6 in4/ft ϕMno= 73.0 kip-in/ft ϕ Vn = 6.52 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 499 439 388 345 309 277 250 226 206 187 171 156 143 131 119
LRFD, ϕW 799 702 621 553 494 444 400 362 329 299 273 250 229 210 193
L/360 - - - - - - - - - - - - - - 119
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2353 2309 2269 2262 2228 2198 2170 2145 2122 2122 2102 2083 2065 2049 2033
PAF Base Steel ≥ .25" 2026 2000 1978 1986 1966 1948 1932 1917 1903 1913 1900 1889 1878 1868 1859

N PANELS
PAF Base Steel ≥ 0.125" 2002 1978 1956 1966 1947 1930 1915 1900 1887 1897 1886 1875 1864 1855 1846
#12 Screw Base Steel ≥ .0385" 1986 1962 1942 1952 1934 1917 1903 1889 1876 1887 1875 1865 1855 1846 1837
Concrete + Deck = 39.4 psf Icr = 95.5 in4/ft Mno/Ω= 53.1 kip-in/ft Vn/Ω = 3.26 kip/ft
(Icr+Iu)/2 = 130 in4/ft Iu = 165.1 in4/ft ϕMno= 81.2 kip-in/ft ϕ Vn = 6.52 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 611 538 477 425 380 342 309 280 255 226 200 179 161 144 131

C PANELS
LRFD, ϕW 978 861 763 680 609 548 495 448 408 372 340 312 287 264 244
L/360 - - - - - - - - 255 226 200 179 161 144 131
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2577 2518 2466 2465 2420 2381 2344 2311 2281 2287 2260 2235 2211 2190 2169
PAF Base Steel ≥ .25" 2155 2121 2091 2110 2083 2059 2038 2018 2000 2017 2001 1985 1971 1957 1945
PAF Base Steel ≥ 0.125" 2109 2078 2051 2071 2047 2025 2004 1986 1969 1988 1972 1958 1944 1932 1920
#12 Screw Base Steel ≥ .0385" 2110 2079 2051 2072 2047 2025 2005 1986 1969 1988 1973 1958 1945 1932 1921
D PANEL

Concrete + Deck = 40.1 psf Icr = 110.8 in4/ft Mno/Ω= 64.4 kip-in/ft Vn/Ω = 3.26 kip/ft
(Icr+Iu)/2 = 143 in /ft
4
Iu = 174.3 in4/ft ϕMno= 98.5 kip-in/ft ϕ Vn = 6.52 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3090 4440 5430 7230 9930
ACUSTADEK®

24 in o.c. 3090 4440 5430 7230 7750


36 in o.c. 3090 4440 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 75


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


6" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.389yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 10' - 3" 11' - 2" 11' - 6" 19 12' - 4" 14' - 1" 14' - 5"
21 11' - 2" 11' - 11" 12' - 4" 18 12' - 9" 15' - 4" 14' - 11"
20 11' - 11" 12' - 8" 13' - 1" 16 13' - 5" 16' - 9" 15' - 9"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 373 326 288 255 227 203 182 164 148 134 121 110 100 91 83
LRFD, ϕW 596 522 460 408 363 324 291 262 236 214 194 176 160 146 133
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2360 2334 2311 2302 2283 2266 2250 2236 2223 2219 2208 2198 2188 2179 2170
PAF Base Steel ≥ .25" 2170 2156 2143 2142 2131 2121 2113 2104 2097 2098 2092 2085 2080 2074 2069
PAF Base Steel ≥ 0.125" 2155 2142 2130 2130 2119 2110 2102 2094 2087 2089 2082 2077 2071 2066 2062
#12 Screw Base Steel ≥ .0385" 2142 2129 2118 2118 2108 2100 2092 2085 2078 2080 2074 2068 2063 2059 2054
Concrete + Deck = 43.0 psf Icr = 87.0 in4/ft Mno/Ω= 40.6 kip-in/ft Vn/Ω = 3.23 kip/ft
(Icr+Iu)/2 = 140 in4/ft Iu = 193.6 in4/ft ϕMno= 62.2 kip-in/ft ϕ Vn = 4.66 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 409 359 317 281 250 224 201 181 164 149 135 123 112 102 93
LRFD, ϕW 655 574 507 449 401 359 322 290 262 238 216 196 179 163 149
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2424 2394 2368 2359 2337 2317 2299 2283 2268 2264 2251 2239 2228 2217 2208
PAF Base Steel ≥ .25" 2206 2190 2175 2175 2163 2151 2141 2131 2123 2125 2117 2110 2103 2097 2091
PAF Base Steel ≥ 0.125" 2189 2174 2160 2161 2149 2138 2129 2120 2111 2114 2107 2100 2094 2088 2082
#12 Screw Base Steel ≥ .0385" 2175 2160 2147 2149 2137 2127 2118 2109 2102 2105 2098 2091 2085 2080 2075
Concrete + Deck = 43.3 psf Icr = 93.4 in4/ft Mno/Ω= 44.4 kip-in/ft Vn/Ω = 3.68 kip/ft
(Icr+Iu)/2 = 145 in4/ft Iu = 196.9 in4/ft ϕMno= 67.9 kip-in/ft ϕ Vn = 5.55 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 444 390 344 305 272 244 219 198 179 163 148 135 123 113 103
LRFD, ϕW 710 623 550 489 436 391 351 317 287 260 237 216 197 180 165
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2472 2439 2411 2401 2377 2355 2336 2318 2301 2298 2284 2270 2258 2246 2235
PAF Base Steel ≥ .25" 2233 2215 2198 2200 2186 2174 2162 2152 2142 2146 2137 2129 2121 2115 2108
PAF Base Steel ≥ 0.125" 2215 2198 2182 2185 2172 2160 2149 2139 2130 2134 2126 2118 2111 2105 2098
#12 Screw Base Steel ≥ .0385" 2200 2183 2169 2172 2159 2148 2138 2128 2120 2124 2116 2109 2102 2096 2090
Concrete + Deck = 43.3 psf Icr = 99.3 in4/ft Mno/Ω= 47.8 kip-in/ft Vn/Ω = 3.68 kip/ft
(Icr+Iu)/2 = 150 in4/ft Iu = 199.9 in4/ft ϕMno= 73.2 kip-in/ft ϕ Vn = 6.35 kip/ft

76 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
6" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.389yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 514 452 399 355 317 285 257 232 210 191 174 159 146 134 123
LRFD, ϕW 823 723 639 568 508 456 410 371 337 306 279 255 233 214 196
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2575 2537 2502 2494 2465 2439 2415 2393 2374 2372 2355 2339 2323 2309 2296
PAF Base Steel ≥ .25" 2292 2270 2250 2255 2238 2223 2209 2196 2185 2191 2180 2171 2161 2153 2145
PAF Base Steel ≥ 0.125" 2271 2250 2231 2237 2221 2207 2194 2181 2170 2177 2167 2158 2149 2141 2134
#12 Screw Base Steel ≥ .0385" 2255 2235 2217 2224 2208 2194 2182 2170 2160 2167 2157 2148 2140 2132 2125
Concrete + Deck = 43.8 psf Icr = 110.9 in4/ft Mno/Ω= 54.9 kip-in/ft Vn/Ω = 3.68 kip/ft
(Icr+Iu)/2 = 159 in4/ft Iu = 206.1 in4/ft ϕMno= 84.0 kip-in/ft ϕ Vn = 7.35 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 577 507 449 399 357 321 289 262 238 217 198 181 166 153 140
LRFD, ϕW 923 811 718 639 571 513 463 419 381 347 317 290 266 244 225
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2678 2633 2593 2586 2552 2522 2494 2469 2446 2446 2426 2407 2389 2373 2357
PAF Base Steel ≥ .25" 2350 2325 2302 2310 2290 2272 2256 2241 2227 2237 2224 2213 2202 2192 2183

N PANELS
PAF Base Steel ≥ 0.125" 2326 2302 2280 2290 2271 2254 2239 2225 2212 2222 2210 2199 2189 2179 2170
#12 Screw Base Steel ≥ .0385" 2310 2287 2266 2276 2258 2242 2227 2213 2201 2211 2200 2189 2179 2170 2161
Concrete + Deck = 44.0 psf Icr = 120.7 in4/ft Mno/Ω= 61.2 kip-in/ft Vn/Ω = 3.68 kip/ft
(Icr+Iu)/2 = 166 in4/ft Iu = 211.7 in4/ft ϕMno= 93.6 kip-in/ft ϕ Vn = 7.35 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 706 622 551 491 440 396 358 324 295 269 247 226 204 184 166

C PANELS
LRFD, ϕW 1130 994 881 785 704 633 572 519 472 431 394 362 333 307 283
L/360 - - - - - - - - - - - - 204 184 166
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2901 2842 2790 2789 2745 2705 2668 2635 2605 2611 2584 2559 2535 2514 2493
PAF Base Steel ≥ .25" 2479 2445 2415 2434 2407 2383 2362 2342 2324 2341 2325 2309 2295 2281 2269
PAF Base Steel ≥ 0.125" 2433 2402 2375 2395 2371 2349 2328 2310 2293 2312 2296 2282 2268 2256 2244
#12 Screw Base Steel ≥ .0385" 2434 2403 2375 2396 2371 2349 2329 2310 2294 2312 2297 2282 2269 2256 2245
D PANEL

Concrete + Deck = 44.7 psf Icr = 140.1 in4/ft Mno/Ω= 74.2 kip-in/ft Vn/Ω = 3.68 kip/ft
(Icr+Iu)/2 = 182 in4/ft Iu = 223.0 in4/ft ϕMno= 113.6 kip-in/ft ϕ Vn = 7.35 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3460 4810 5800 7600 10300
ACUSTADEK®

24 in o.c. 3460 4810 5800 7600 7750


36 in o.c. 3460 4810 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 77


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


6 1⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.466yd3/100ft2
2 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 10' - 1" 10' - 11" 11' - 4" 19 12' - 2" 13' - 10" 14' - 3"
21 11' - 0" 11' - 9" 12' - 1" 18 12' - 7" 15' - 1" 14' - 9"
20 11' - 9" 12' - 5" 12' - 10" 16 13' - 3" 16' - 6" 15' - 7"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 398 349 308 273 243 217 195 175 158 143 130 118 107 98 89
LRFD, ϕW 637 558 492 436 388 347 311 280 253 229 208 188 171 156 142
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2522 2496 2473 2464 2445 2428 2412 2398 2385 2381 2370 2360 2350 2341 2332
PAF Base Steel ≥ .25" 2332 2318 2305 2304 2293 2283 2275 2266 2259 2260 2254 2247 2242 2236 2231
PAF Base Steel ≥ 0.125" 2317 2304 2292 2292 2281 2272 2264 2256 2249 2251 2244 2239 2233 2228 2224
#12 Screw Base Steel ≥ .0385" 2304 2291 2280 2280 2270 2262 2254 2247 2240 2242 2236 2231 2225 2221 2216
Concrete + Deck = 45.3 psf Icr = 97.0 in4/ft Mno/Ω= 43.4 kip-in/ft Vn/Ω = 3.34 kip/ft
(Icr+Iu)/2 = 158 in4/ft Iu = 218.1 in4/ft ϕMno= 66.4 kip-in/ft ϕ Vn = 4.82 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 438 384 339 300 268 240 215 194 176 159 145 132 120 109 100
LRFD, ϕW 700 614 542 481 428 384 345 311 281 255 231 210 192 175 160
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2586 2557 2530 2521 2499 2479 2461 2445 2430 2427 2413 2401 2390 2379 2370
PAF Base Steel ≥ .25" 2368 2352 2337 2337 2325 2313 2303 2293 2285 2287 2279 2272 2265 2259 2253
PAF Base Steel ≥ 0.125" 2351 2336 2322 2323 2311 2300 2291 2282 2274 2276 2269 2262 2256 2250 2245
#12 Screw Base Steel ≥ .0385" 2337 2322 2309 2311 2299 2289 2280 2271 2264 2267 2260 2254 2247 2242 2237
Concrete + Deck = 45.6 psf Icr = 104.2 in4/ft Mno/Ω= 47.4 kip-in/ft Vn/Ω = 3.89 kip/ft
(Icr+Iu)/2 = 163 in4/ft Iu = 221.7 in4/ft ϕMno= 72.5 kip-in/ft ϕ Vn = 5.71 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 475 416 368 327 291 261 235 212 192 174 158 144 132 121 110
LRFD, ϕW 759 666 588 522 466 418 376 339 307 279 254 231 211 193 177
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2634 2601 2573 2563 2539 2517 2498 2480 2463 2460 2446 2432 2420 2408 2397
PAF Base Steel ≥ .25" 2395 2377 2360 2362 2348 2336 2324 2314 2304 2308 2299 2291 2283 2277 2270
PAF Base Steel ≥ 0.125" 2377 2360 2344 2347 2334 2322 2311 2301 2292 2296 2288 2280 2273 2267 2260
#12 Screw Base Steel ≥ .0385" 2362 2345 2331 2334 2321 2310 2300 2290 2282 2286 2278 2271 2264 2258 2252
Concrete + Deck = 45.6 psf Icr = 110.8 in4/ft Mno/Ω= 51.1 kip-in/ft Vn/Ω = 3.89 kip/ft
(Icr+Iu)/2 = 168 in4/ft Iu = 225.1 in4/ft ϕMno= 78.1 kip-in/ft ϕ Vn = 6.51 kip/ft

78 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
6 1⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.466yd3/100ft2
2 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 550 483 427 380 339 305 275 248 225 205 187 171 156 143 132
LRFD, ϕW 880 773 684 608 543 488 439 397 360 328 299 273 250 229 211
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2737 2699 2664 2656 2627 2601 2577 2555 2536 2534 2517 2501 2485 2471 2458
PAF Base Steel ≥ .25" 2454 2432 2412 2417 2400 2385 2371 2358 2347 2353 2342 2333 2323 2315 2307
PAF Base Steel ≥ 0.125" 2433 2412 2393 2399 2383 2369 2356 2344 2333 2339 2329 2320 2311 2303 2296
#12 Screw Base Steel ≥ .0385" 2417 2397 2379 2386 2370 2356 2344 2332 2322 2329 2319 2310 2302 2294 2287
Concrete + Deck = 46.1 psf Icr = 123.8 in4/ft Mno/Ω= 58.7 kip-in/ft Vn/Ω = 3.89 kip/ft
(Icr+Iu)/2 = 178 in4/ft Iu = 231.9 in4/ft ϕMno= 89.8 kip-in/ft ϕ Vn = 7.79 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 617 542 480 427 382 343 310 281 255 232 212 194 178 164 151
LRFD, ϕW 987 868 768 684 612 549 496 449 408 371 339 310 285 262 241
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2840 2795 2755 2748 2714 2684 2656 2631 2608 2608 2588 2569 2551 2535 2519
PAF Base Steel ≥ .25" 2512 2487 2464 2472 2452 2434 2418 2403 2389 2399 2386 2375 2364 2354 2345

N PANELS
PAF Base Steel ≥ 0.125" 2488 2464 2443 2452 2433 2416 2401 2387 2374 2384 2372 2361 2351 2341 2332
#12 Screw Base Steel ≥ .0385" 2472 2449 2428 2438 2420 2404 2389 2375 2363 2373 2362 2351 2341 2332 2323
Concrete + Deck = 46.3 psf Icr = 134.8 in4/ft Mno/Ω= 65.4 kip-in/ft Vn/Ω = 3.89 kip/ft
(Icr+Iu)/2 = 186 in4/ft Iu = 238.1 in4/ft ϕMno= 100.1 kip-in/ft ϕ Vn = 7.79 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 755 665 589 525 471 424 383 347 316 289 264 242 223 205 186

C PANELS
LRFD, ϕW 1209 1064 943 841 753 678 613 556 506 462 423 388 357 329 303
L/360 - - - - - - - - - - - - - - 186
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3063 3004 2952 2951 2907 2867 2830 2797 2767 2773 2746 2721 2697 2676 2655
PAF Base Steel ≥ .25" 2641 2607 2577 2596 2569 2545 2524 2504 2486 2503 2487 2471 2457 2443 2431
PAF Base Steel ≥ 0.125" 2595 2564 2537 2557 2533 2511 2490 2472 2455 2474 2458 2444 2430 2418 2406
#12 Screw Base Steel ≥ .0385" 2596 2565 2537 2558 2533 2511 2491 2472 2456 2474 2459 2444 2431 2418 2407
D PANEL

Concrete + Deck = 47.0 psf Icr = 156.5 in4/ft Mno/Ω= 79.4 kip-in/ft Vn/Ω = 3.89 kip/ft
(Icr+Iu)/2 = 204 in4/ft Iu = 250.6 in4/ft ϕMno= 121.4 kip-in/ft ϕ Vn = 7.79 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 4990 5980 7780 10480
ACUSTADEK®

24 in o.c. n/a 4990 5980 7750 7750


36 in o.c. n/a 4990 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 79


TABLE OF CONTENTS

2.4 3WxH-36 Composite Deck


7 3⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.755yd3/100ft2
3 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 9' - 5" 10' - 4" 10' - 8" 19 11' - 9" 13' - 1" 13' - 6"
21 10' - 3" 11' - 0" 11' - 5" 18 12' - 1" 14' - 3" 14' - 2"
20 11' - 1" 11' - 9" 12' - 1" 16 12' - 9" 15' - 10" 14' - 11"

GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 498 437 385 341 304 272 244 220 199 180 164 149 135 124 113
LRFD, ϕW 797 699 616 546 487 436 391 352 318 288 262 238 217 198 180
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3129 3104 3081 3071 3052 3035 3020 3006 2993 2989 2978 2967 2958 2949 2940
PAF Base Steel ≥ .25" 2940 2925 2913 2912 2901 2891 2882 2874 2867 2868 2861 2855 2849 2844 2839
PAF Base Steel ≥ 0.125" 2925 2911 2899 2899 2889 2880 2871 2864 2857 2858 2852 2846 2841 2836 2831
#12 Screw Base Steel ≥ .0385" 2911 2898 2887 2888 2878 2869 2861 2854 2848 2850 2844 2838 2833 2828 2824
Concrete + Deck = 53.9 psf Icr = 140.7 in4/ft Mno/Ω= 54.1 kip-in/ft Vn/Ω = 3.77 kip/ft
(Icr+Iu)/2 = 235 in4/ft Iu = 329.1 in4/ft ϕMno= 82.7 kip-in/ft ϕ Vn = 5.46 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 548 481 424 377 336 301 271 244 221 200 182 166 152 138 127
LRFD, ϕW 876 769 679 603 538 481 433 391 353 321 292 266 242 222 203
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3194 3164 3138 3128 3106 3087 3069 3052 3037 3034 3021 3009 2998 2987 2977
PAF Base Steel ≥ .25" 2976 2959 2944 2945 2932 2921 2910 2901 2892 2895 2887 2880 2873 2867 2861
PAF Base Steel ≥ 0.125" 2959 2943 2929 2931 2919 2908 2898 2889 2881 2884 2877 2870 2864 2858 2852
#12 Screw Base Steel ≥ .0385" 2944 2930 2916 2918 2907 2897 2888 2879 2871 2875 2868 2861 2855 2849 2844
Concrete + Deck = 54.2 psf Icr = 151.3 in4/ft Mno/Ω= 59.1 kip-in/ft Vn/Ω = 4.43 kip/ft
(Icr+Iu)/2 = 243 in4/ft Iu = 334.2 in4/ft ϕMno= 90.4 kip-in/ft ϕ Vn = 6.35 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 594 522 461 410 366 328 295 267 241 219 200 182 167 153 140
LRFD, ϕW 951 835 737 655 585 525 472 426 386 351 320 292 267 244 224
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3241 3209 3180 3171 3147 3125 3105 3087 3071 3068 3053 3040 3027 3016 3005
PAF Base Steel ≥ .25" 3003 2984 2968 2970 2956 2943 2932 2921 2912 2915 2906 2899 2891 2884 2878
PAF Base Steel ≥ 0.125" 2985 2967 2952 2954 2941 2929 2918 2909 2899 2904 2895 2888 2881 2874 2868
#12 Screw Base Steel ≥ .0385" 2969 2953 2938 2942 2929 2918 2907 2898 2889 2894 2886 2879 2872 2866 2860
Concrete + Deck = 54.2 psf Icr = 161.0 in4/ft Mno/Ω= 63.7 kip-in/ft Vn/Ω = 4.75 kip/ft
(Icr+Iu)/2 = 250 in4/ft Iu = 338.9 in4/ft ϕMno= 97.5 kip-in/ft ϕ Vn = 7.15 kip/ft

80 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

3WxH-36 Composite Deck 2.4

GENERAL INFORMATION
7 3⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.755yd3/100ft2
3 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 689 606 536 477 426 383 345 312 284 258 236 215 197 181 167
LRFD, ϕW 1103 969 858 763 682 613 552 500 454 413 377 345 316 290 267
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 3345 3306 3272 3263 3234 3208 3185 3163 3143 3142 3124 3108 3093 3079 3066
PAF Base Steel ≥ .25" 3061 3039 3020 3025 3008 2992 2978 2966 2954 2960 2950 2940 2931 2923 2915
PAF Base Steel ≥ 0.125" 3040 3020 3001 3007 2991 2976 2963 2951 2940 2947 2937 2928 2919 2911 2904
#12 Screw Base Steel ≥ .0385" 3024 3004 2987 2993 2978 2964 2951 2940 2929 2937 2927 2918 2910 2902 2895
Concrete + Deck = 54.7 psf Icr = 180.1 in4/ft Mno/Ω= 73.3 kip-in/ft Vn/Ω = 4.75 kip/ft
(Icr+Iu)/2 = 264 in4/ft Iu = 348.7 in4/ft ϕMno= 112.2 kip-in/ft ϕ Vn = 8.61 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 774 681 603 537 481 432 390 353 321 293 268 245 225 207 191
LRFD, ϕW 1239 1090 965 859 769 692 624 566 514 469 428 392 360 331 305
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3447 3402 3362 3355 3322 3291 3264 3238 3215 3216 3195 3176 3159 3142 3127
PAF Base Steel ≥ .25" 3120 3094 3071 3080 3060 3042 3026 3011 2997 3006 2994 2982 2972 2962 2953

N PANELS
PAF Base Steel ≥ 0.125" 3096 3072 3050 3060 3041 3024 3008 2994 2981 2991 2979 2968 2958 2949 2940
#12 Screw Base Steel ≥ .0385" 3079 3056 3035 3046 3028 3011 2996 2983 2970 2981 2969 2959 2949 2940 2931
Concrete + Deck = 54.9 psf Icr = 196.5 in4/ft Mno/Ω= 81.9 kip-in/ft Vn/Ω = 4.75 kip/ft
(Icr+Iu)/2 = 277 in4/ft Iu = 357.4 in4/ft ϕMno= 125.3 kip-in/ft ϕ Vn = 9.49 kip/ft

Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 950 837 742 662 593 534 483 438 399 365 334 307 282 260 240

C PANELS
LRFD, ϕW 1520 1339 1187 1059 949 854 773 701 639 583 534 491 451 416 385
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3670 3612 3560 3558 3514 3474 3438 3405 3374 3381 3354 3328 3305 3283 3263
PAF Base Steel ≥ .25" 3249 3215 3185 3203 3177 3153 3131 3112 3093 3111 3094 3079 3064 3051 3038
PAF Base Steel ≥ 0.125" 3203 3172 3144 3165 3140 3118 3098 3080 3063 3082 3066 3052 3038 3026 3014
#12 Screw Base Steel ≥ .0385" 3204 3172 3145 3165 3141 3119 3098 3080 3063 3082 3066 3052 3038 3026 3014
D PANEL

Concrete + Deck = 55.6 psf Icr = 228.6 in4/ft Mno/Ω= 99.6 kip-in/ft Vn/Ω = 4.75 kip/ft
(Icr+Iu)/2 = 302 in4/ft Iu = 375.1 in4/ft ϕMno= 152.3 kip-in/ft ϕ Vn = 9.49 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 5680 6670 8470 11170
ACUSTADEK®

24 in o.c. n/a 5680 6670 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 81


TABLE OF CONTENTS

3.1 2WH-36
12" 5" 12" 5"

2-1/8" 2-1/8"

5" 5"
36" 36"
2WH-36 Profile 2WHS-36 Profile

36/4

36/4 Attachment Pattern

2W Series Embossment
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
22 1.57 0.029 50 65 0.448 0.353 1.04 0.340 0.890
21 1.78 0.033 50 65 0.509 0.403 1.04 0.385 0.889
20 1.89 0.035 50 65 0.540 0.427 1.05 0.408 0.880
19 2.25 0.042 50 65 0.647 0.510 1.05 0.486 0.887
18 2.51 0.047 50 65 0.722 0.567 1.05 0.541 0.886
16 3.14 0.059 50 65 0.903 0.703 1.05 0.670 0.883

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending
Distance to Distance to Uniform Load Only
Section N.A. from Section N.A. from Moment of Moment of
Gage Area Modulus Bottom Modulus Bottom Inertia Inertia Id = (2Ie+Ig)/3
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
22 0.315 0.247 0.92 0.252 1.18 0.330 0.327 0.338 0.336
21 0.383 0.298 0.95 0.304 1.15 0.387 0.383 0.392 0.390
20 0.419 0.325 0.96 0.331 1.14 0.417 0.410 0.420 0.416
19 0.551 0.408 0.98 0.419 1.11 0.523 0.517 0.519 0.514
18 0.650 0.468 1.00 0.483 1.10 0.567 0.563 0.567 0.564
16 0.882 0.614 1.03 0.640 1.07 0.703 0.703 0.703 0.703

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 6" 1" 2" 4" 6"
End 316 393 503 588 483 602 770 899
22
Interior 528 638 792 911 786 948 1178 1355
End 403 499 636 741 616 764 973 1133
21
Interior 675 810 1001 1148 1004 1205 1489 1708
End 450 556 707 822 688 851 1081 1258
20
Interior 755 903 1114 1275 1123 1344 1657 1897
End 633 777 980 1137 968 1188 1500 1739
19
Interior 1066 1266 1549 1766 1585 1883 2304 2627
End 781 954 1199 1387 1195 1460 1835 2122
18
Interior 1319 1559 1898 2158 1961 2318 2823 3211
End 1194 1445 1800 2072 1827 2211 2754 3170
16
Interior 2027 2373 2862 3237 3015 3530 4257 4815
Web Crippling Constraints h=2.16" r=0.125" θ=64º

82 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WHF-36 3.2

GENERAL INFORMATION
12" 5"

2-1/8"
36/4
5"
36" 36/4 Attachment Pattern
2WHF-36 Profile

3W PANELS
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 3.49 0.035 / 0.036 50 65 1.008 0.770 0.65 0.496 0.874

2W PANELS
20/18 3.96 0.035 / 0.047 50 65 1.147 0.820 0.58 0.504 0.845
20/16 4.48 0.035 / 0.059 50 65 1.299 0.864 0.53 0.510 0.815
18/20 4.11 0.047 / 0.036 50 65 1.193 0.968 0.73 0.653 0.901
18/18 4.58 0.047 / 0.047 50 65 1.332 1.032 0.66 0.663 0.880
18/16 5.10 0.047 / 0.059 50 65 1.484 1.090 0.61 0.672 0.857
16/20 4.74 0.059 / 0.036 50 65 1.381 1.159 0.79 0.809 0.916
16/18 5.21 0.059 / 0.047 50 65 1.520 1.235 0.73 0.822 0.901
16/16 5.73 0.059 / 0.059 50 65 1.671 1.306 0.68 0.833 0.884

B PANELS
Effective Section Modulus at Fy
Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie + I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft

N PANELS
20/20 0.510 0.391 0.56 0.457 1.00 0.732 0.603 0.745 0.659
20/18 0.591 0.401 0.50 0.476 0.87 0.776 0.690 0.791 0.733
20/16 0.692 0.406 0.46 0.492 0.73 0.816 0.771 0.832 0.802
18/20 0.722 0.596 0.69 0.598 1.07 0.966 0.754 0.967 0.825
18/18 0.803 0.605 0.63 0.621 0.96 1.030 0.854 1.030 0.913
18/16 0.904 0.614 0.58 0.644 0.83 1.088 0.954 1.089 1.000
16/20 0.939 0.779 0.77 0.740 1.10 1.156 0.905 1.157 0.989
16/18 1.020 0.792 0.71 0.766 1.01 1.232 1.017 1.233 1.089

C PANELS
16/16 1.121 0.803 0.66 0.792 0.91 1.303 1.132 1.304 1.190

D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 83


TABLE OF CONTENTS

3.3 2WHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

2WHF-36 Cellular Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 39.1 9' - 9" 10' - 10" 10' - 11"
20/18 39.6 9' - 10" 11' - 8" 10' - 11"
20/16 40.1 9' - 10" 11' - 11" 10' - 11"
18/20 39.8 12' - 1" 11' - 10" 13' - 4"
4 0.907 18/18 40.3 12' - 3" 13' - 4" 13' - 4"
18/16 40.8 12' - 4" 13' - 7" 13' - 4"
16/20 40.4 12' - 9" 12' - 10" 13' - 4"
16/18 40.9 12' - 11" 14' - 5" 13' - 4"
16/16 41.4 13' - 1" 15' - 1" 13' - 4"
20/20 51.2 8' - 10" 9' - 11" 9' - 11"
20/18 51.7 8' - 11" 10' - 8" 10' - 0"
20/16 52.2 8' - 11" 10' - 11" 10' - 0"
18/20 51.9 11' - 4" 10' - 10" 12' - 3"
5 1.215 18/18 52.3 11' - 5" 12' - 3" 12' - 4"
18/16 52.9 11' - 6" 12' - 6" 12' - 4"
16/20 52.5 12' - 0" 11' - 9" 13' - 4"
16/18 53.0 12' - 2" 13' - 2" 13' - 4"
16/16 53.5 12' - 3" 13' - 10" 13' - 4"
20/20 57.2 8' - 6" 9' - 6" 9' - 7"
20/18 57.7 8' - 6" 10' - 4" 9' - 7"
20/16 58.2 8' - 7" 10' - 6" 9' - 8"
5 1/2
18/20 57.9 10' - 11" 10' - 5" 11' - 10"
1.370 18/18 58.4 11' - 0" 11' - 9" 11' - 10"
1 Hour
18/16 58.9 11' - 0" 12' - 0" 11' - 11"
Fire Rating
16/20 58.6 11' - 8" 11' - 4" 13' - 0"
16/18 59.0 11' - 10" 12' - 8" 13' - 3"
16/16 59.6 12' - 0" 13' - 3" 13' - 4"
20/20 69.3 7' - 11" 8' - 11" 8' - 11"
20/18 69.8 7' - 11" 9' - 7" 9' - 0"
20/16 70.3 8' - 0" 9' - 9" 9' - 0"
6 1/2
18/20 70.0 10' - 2" 9' - 9" 11' - 0"
1.678 18/18 70.5 10' - 2" 11' - 0" 11' - 1"
2 Hour
18/16 71.0 10' - 3" 11' - 2" 11' - 1"
Fire Rating
16/20 70.7 11' - 2" 10' - 7" 12' - 6"
16/18 71.1 11' - 4" 11' - 10" 12' - 8"
16/16 71.7 11' - 6" 12' - 5" 12' - 10"
20/20 78.4 7' - 6" 8' - 6" 8' - 6"
20/18 78.9 7' - 7" 9' - 2" 8' - 7"
20/16 79.4 7' - 8" 9' - 4" 8' - 7"
7 1/4
18/20 79.0 9' - 8" 9' - 4" 10' - 6"
1.910 18/18 79.5 9' - 9" 10' - 6" 10' - 7"
3 Hour
18/16 80.0 9' - 9" 10' - 8" 10' - 7"
Fire Rating
16/20 79.7 10' - 9" 10' - 1" 12' - 1"
16/18 80.2 10' - 11" 11' - 4" 12' - 4"
16/16 80.7 11' - 1" 11' - 10" 12' - 5"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

84 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WHF-36 Cellular Composite Deck 3.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
2WHF-36 Cellular Shoring Table
110 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 30.6 10' - 9" 11' - 10" 11' - 10"
20/18 31.0 10' - 10" 12' - 9" 11' - 11"
20/16 31.5 10' - 10" 13' - 0" 11' - 11"
18/20 31.2 12' - 11" 12' - 11" 13' - 4"

2W PANELS
4 0.907 18/18 31.7 13' - 0" 14' - 6" 13' - 4"
18/16 32.2 13' - 2" 14' - 10" 13' - 4"
16/20 31.9 13' - 7" 14' - 0" 13' - 4"
16/18 32.4 13' - 9" 15' - 8" 13' - 4"
16/16 32.9 13' - 10" 16' - 5" 13' - 4"
20/20 35.1 10' - 3" 11' - 4" 11' - 4"
20/18 35.6 10' - 3" 12' - 2" 11' - 5"
20/16 36.1 10' - 4" 12' - 5" 11' - 5"
4 1/2

B PANELS
18/20 35.8 12' - 6" 12' - 4" 13' - 4"
1.061 18/18 36.3 12' - 8" 13' - 11" 13' - 4"
1 Hour
18/16 36.8 12' - 9" 14' - 2" 13' - 4"
Fire Rating
16/20 36.5 13' - 2" 13' - 5" 13' - 4"
16/18 36.9 13' - 4" 15' - 0" 13' - 4"
16/16 37.5 13' - 5" 15' - 8" 13' - 4"
20/20 39.7 9' - 9" 10' - 10" 10' - 11"
20/18 40.2 9' - 10" 11' - 9" 11' - 0"

N PANELS
20/16 40.7 9' - 11" 11' - 11" 11' - 0"
18/20 40.4 12' - 1" 11' - 11" 13' - 4"
5 1.215 18/18 40.9 12' - 3" 13' - 5" 13' - 4"
18/16 41.4 12' - 5" 13' - 8" 13' - 4"
16/20 41.0 12' - 9" 12' - 10" 13' - 4"
16/18 41.5 12' - 11" 14' - 5" 13' - 4"
16/16 42.0 13' - 1" 15' - 1" 13' - 4"
20/20 42.0 9' - 7" 10' - 8" 10' - 9"

C PANELS
20/18 42.5 9' - 8" 11' - 6" 10' - 9"
20/16 43.0 9' - 8" 11' - 9" 10' - 10"
5 1/4
18/20 42.7 12' - 0" 11' - 8" 13' - 2"
1.292 18/18 43.1 12' - 1" 13' - 2" 13' - 3"
2 Hour
18/16 43.7 12' - 3" 13' - 5" 13' - 3"
Fire Rating
16/20 43.3 12' - 7" 12' - 8" 13' - 4"
16/18 43.8 12' - 9" 14' - 2" 13' - 4"
16/16 44.3 12' - 11" 14' - 10" 13' - 4"
20/20 50.6 8' - 11" 10' - 0" 10' - 1"
D PANEL

20/18 51.1 9' - 0" 10' - 10" 10' - 1"


20/16 51.6 9' - 0" 11' - 0" 10' - 2"
6 3/16
18/20 51.3 11' - 5" 11' - 0" 12' - 5"
1.582 18/18 51.7 11' - 7" 12' - 4" 12' - 5"
3 Hour
18/16 52.3 11' - 8" 12' - 7" 12' - 6"
Fire Rating
16/20 51.9 12' - 1" 11' - 10" 13' - 4"
16/18 52.4 12' - 3" 13' - 4" 13' - 4"
ACUSTADEK®

16/16 52.9 12' - 4" 13' - 11" 13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 85


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 0.907yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 11" 8' - 9" 9' - 5" 19 10' - 4" 11' - 9" 12' - 2"
21 9' - 0" 9' - 11" 10' - 4" 18 10' - 8" 12' - 7" 12' - 8"
20 9' - 6" 10' - 6" 10' - 10" 16 11' - 4" 14' - 2" 13' - 4"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 395 332 283 243 210 183 160 141 124 110 98 87 78 70 62
LRFD, ϕW 632 532 452 388 336 292 256 225 199 176 157 140 125 111 100
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2362 2335 2298 2265 2237 2212 2190 2180 2162 2145 2130 2116 2103 2100 2089
PAF Base Steel ≥ .25" 2115 2107 2086 2067 2051 2037 2024 2024 2013 2004 1995 1987 1979 1981 1974
PAF Base Steel ≥ 0.125" 2095 2089 2069 2052 2037 2023 2012 2012 2002 1992 1984 1977 1970 1971 1965
#12 Screw Base Steel ≥ .0385" 2077 2072 2054 2037 2023 2011 2000 2000 1991 1982 1974 1967 1961 1963 1957
Concrete + Deck = 37.1 psf Icr = 23.1 in4/ft Mno/Ω= 23.9 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 40.7 in4/ft Iu = 58.3 in4/ft ϕMno= 36.5 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 445 375 320 275 238 208 182 161 142 127 113 101 90 81 73
LRFD, ϕW 713 601 512 440 381 333 292 257 228 203 181 161 145 130 117
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2441 2413 2369 2332 2299 2270 2244 2235 2214 2194 2177 2161 2146 2143 2130
PAF Base Steel ≥ .25" 2157 2150 2125 2104 2085 2069 2054 2055 2043 2032 2021 2012 2003 2006 1998
PAF Base Steel ≥ 0.125" 2135 2130 2106 2087 2069 2054 2040 2041 2030 2019 2009 2001 1992 1996 1988
#12 Screw Base Steel ≥ .0385" 2115 2112 2090 2071 2055 2040 2027 2029 2018 2008 1999 1991 1983 1986 1979
Concrete + Deck = 37.3 psf Icr = 25.4 in4/ft Mno/Ω= 26.7 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 42.4 in4/ft Iu = 59.4 in4/ft ϕMno= 40.9 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 470 396 338 291 252 220 193 171 151 134 120 107 96 87 78
LRFD, ϕW 752 634 540 465 403 352 309 273 242 215 192 172 154 139 125
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2481 2452 2406 2366 2331 2300 2272 2263 2240 2219 2201 2183 2168 2165 2151
PAF Base Steel ≥ .25" 2178 2172 2146 2123 2103 2085 2070 2071 2058 2046 2035 2025 2016 2019 2011
PAF Base Steel ≥ 0.125" 2155 2150 2126 2104 2086 2069 2054 2057 2044 2033 2022 2013 2004 2008 2000
#12 Screw Base Steel ≥ .0385" 2135 2132 2109 2088 2071 2055 2041 2044 2032 2021 2012 2003 1994 1999 1991
Concrete + Deck = 37.4 psf Icr = 26.4 in4/ft Mno/Ω= 28.1 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 43.2 in4/ft Iu = 59.9 in4/ft ϕMno= 43.0 kip-in/ft ϕ Vn = 4.52 kip/ft

86 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 0.907yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 555 469 400 345 300 262 231 204 182 162 145 130 118 106 96
LRFD, ϕW 888 750 640 552 480 420 370 327 291 259 232 209 188 170 154
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2625 2594 2537 2488 2445 2407 2373 2365 2337 2311 2288 2266 2247 2246 2229
PAF Base Steel ≥ .25" 2255 2252 2220 2191 2167 2145 2126 2131 2114 2099 2086 2073 2062 2068 2058
PAF Base Steel ≥ 0.125" 2227 2227 2196 2169 2146 2126 2108 2113 2098 2083 2070 2059 2048 2055 2045
#12 Screw Base Steel ≥ .0385" 2206 2207 2178 2152 2130 2111 2093 2100 2085 2071 2059 2048 2037 2045 2035
Concrete + Deck = 37.7 psf Icr = 30.1 in4/ft Mno/Ω= 32.9 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 45.9 in4/ft Iu = 61.8 in4/ft ϕMno= 50.4 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 613 518 443 382 332 291 256 227 202 181 162 146 129 114 102
LRFD, ϕW 980 828 708 611 531 466 410 364 324 289 260 234 211 191 173
L/360 - - - - - - - - - - - - 129 114 102
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2731 2700 2635 2579 2530 2486 2448 2441 2409 2380 2353 2329 2306 2307 2287
PAF Base Steel ≥ .25" 2311 2312 2275 2243 2215 2190 2168 2176 2157 2140 2124 2109 2096 2105 2093

N PANELS
PAF Base Steel ≥ 0.125" 2280 2284 2249 2218 2192 2168 2147 2157 2139 2122 2107 2093 2081 2091 2079
#12 Screw Base Steel ≥ .0385" 2259 2264 2230 2201 2176 2153 2133 2143 2126 2110 2095 2082 2070 2080 2069
Concrete + Deck = 38.0 psf Icr = 32.5 in4/ft Mno/Ω= 36.2 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 47.7 in4/ft Iu = 63.0 in4/ft ϕMno= 55.4 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 746 631 540 467 407 357 315 280 242 209 182 159 140 124 110

C PANELS
LRFD, ϕW 1193 1010 864 747 651 571 505 448 400 358 322 291 264 239 218
L/360 - - - - - - - - 242 209 182 159 140 124 110
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2996 2967 2882 2809 2744 2688 2637 2636 2594 2555 2520 2488 2458 2464 2438
PAF Base Steel ≥ .25" 2453 2466 2417 2375 2337 2305 2276 2294 2268 2245 2224 2205 2187 2204 2188
PAF Base Steel ≥ 0.125" 2396 2413 2368 2329 2294 2264 2237 2257 2234 2212 2192 2175 2158 2177 2161
#12 Screw Base Steel ≥ .0385" 2394 2412 2366 2327 2293 2263 2236 2256 2233 2211 2192 2174 2157 2176 2161
D PANEL

Concrete + Deck = 38.6 psf Icr = 37.8 in4/ft Mno/Ω= 43.8 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 51.8 in4/ft Iu = 65.9 in4/ft ϕMno= 66.9 kip-in/ft ϕ Vn = 4.52 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3080 4430 5420 7220 9920
ACUSTADEK®

24 in o.c. 3080 4430 5420 7220 7750


36 in o.c. 3080 4430 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 87


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


41⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.061yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 7" 8' - 4" 8' - 11" 19 9' - 11" 11' - 2" 11' - 7"
21 8' - 7" 9' - 6" 9' - 11" 18 10' - 2" 12' - 0" 12' - 3"
20 9' - 0" 10' - 0" 10' - 4" 16 10' - 11" 13' - 8" 12' - 10"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 477 401 342 293 254 221 194 171 151 134 119 106 95 85 76
LRFD, ϕW 763 642 547 470 406 354 310 273 242 214 191 170 152 136 122
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2853 2826 2788 2756 2727 2702 2680 2671 2652 2635 2620 2606 2594 2590 2579
PAF Base Steel ≥ .25" 2605 2597 2576 2558 2542 2527 2515 2514 2504 2494 2485 2477 2470 2471 2465
PAF Base Steel ≥ 0.125" 2586 2579 2559 2542 2527 2514 2502 2502 2492 2483 2475 2467 2460 2462 2456
#12 Screw Base Steel ≥ .0385" 2568 2563 2544 2528 2514 2501 2490 2491 2481 2473 2465 2458 2451 2453 2447
Concrete + Deck = 43.1 psf Icr = 31.5 in4/ft Mno/Ω= 28.7 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 56.9 in4/ft Iu = 82.3 in4/ft ϕMno= 44.0 kip-in/ft ϕ Vn = 5.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 538 454 387 333 288 252 221 195 173 154 137 123 110 99 89
LRFD, ϕW 861 726 619 532 462 403 354 312 277 246 220 197 176 158 142
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2932 2903 2860 2822 2789 2760 2735 2725 2704 2685 2667 2651 2636 2633 2620
PAF Base Steel ≥ .25" 2647 2640 2616 2594 2576 2559 2545 2546 2533 2522 2512 2502 2494 2496 2489
PAF Base Steel ≥ 0.125" 2625 2620 2597 2577 2559 2544 2530 2532 2520 2509 2500 2491 2483 2486 2479
#12 Screw Base Steel ≥ .0385" 2606 2602 2580 2562 2545 2530 2517 2520 2508 2498 2489 2481 2473 2477 2470
Concrete + Deck = 43.3 psf Icr = 34.7 in4/ft Mno/Ω= 32.2 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 59.2 in4/ft Iu = 83.7 in4/ft ϕMno= 49.3 kip-in/ft ϕ Vn = 5.26 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 568 479 408 352 305 267 234 207 184 163 146 131 118 106 95
LRFD, ϕW 908 766 654 563 488 426 375 331 294 262 234 209 188 169 152
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2972 2942 2896 2856 2821 2790 2763 2754 2731 2710 2691 2674 2658 2655 2641
PAF Base Steel ≥ .25" 2668 2662 2636 2613 2593 2576 2560 2562 2548 2536 2525 2515 2506 2510 2501
PAF Base Steel ≥ 0.125" 2645 2641 2616 2595 2576 2560 2545 2547 2535 2523 2513 2503 2495 2498 2491
#12 Screw Base Steel ≥ .0385" 2625 2623 2599 2579 2561 2546 2532 2535 2523 2512 2502 2493 2485 2489 2482
Concrete + Deck = 43.4 psf Icr = 36.2 in4/ft Mno/Ω= 33.9 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 60.3 in4/ft Iu = 84.4 in4/ft ϕMno= 51.9 kip-in/ft ϕ Vn = 5.26 kip/ft

88 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
41⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.061yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 671 567 485 418 363 318 280 248 221 197 177 159 143 129 117
LRFD, ϕW 1074 908 775 669 581 509 448 397 353 315 283 254 229 207 187
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 3116 3085 3028 2978 2935 2897 2863 2855 2827 2801 2778 2757 2737 2736 2719
PAF Base Steel ≥ .25" 2745 2742 2710 2682 2657 2636 2616 2621 2605 2590 2576 2563 2552 2558 2548
PAF Base Steel ≥ 0.125" 2717 2717 2686 2660 2637 2616 2598 2604 2588 2574 2561 2549 2538 2545 2535
#12 Screw Base Steel ≥ .0385" 2696 2697 2668 2643 2621 2601 2584 2591 2575 2562 2549 2538 2528 2535 2525
Concrete + Deck = 43.8 psf Icr = 41.2 in4/ft Mno/Ω= 39.8 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 64.1 in4/ft Iu = 86.9 in4/ft ϕMno= 60.8 kip-in/ft ϕ Vn = 5.26 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 742 627 536 463 403 353 311 276 246 220 197 178 161 145 132
LRFD, ϕW 1187 1003 858 740 644 565 498 442 393 352 316 285 257 233 211
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3222 3190 3125 3069 3020 2977 2938 2932 2899 2870 2843 2819 2797 2797 2778
PAF Base Steel ≥ .25" 2802 2803 2765 2733 2705 2680 2658 2667 2647 2630 2614 2600 2587 2596 2584

N PANELS
PAF Base Steel ≥ 0.125" 2771 2774 2739 2709 2682 2659 2638 2647 2629 2612 2598 2584 2571 2581 2570
#12 Screw Base Steel ≥ .0385" 2749 2754 2721 2692 2666 2643 2623 2633 2616 2600 2586 2573 2561 2571 2560
Concrete + Deck = 44.0 psf Icr = 44.5 in4/ft Mno/Ω= 43.7 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 66.5 in4/ft Iu = 88.5 in4/ft ϕMno= 66.9 kip-in/ft ϕ Vn = 5.26 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 904 765 655 567 494 434 383 341 304 273 245 222 195 173 153

C PANELS
LRFD, ϕW 1447 1225 1049 907 790 694 613 545 487 436 393 355 321 292 266
L/360 - - - - - - - - - - - 222 195 173 153
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3486 3457 3372 3299 3235 3178 3128 3127 3084 3045 3010 2978 2949 2955 2929
PAF Base Steel ≥ .25" 2944 2956 2907 2865 2828 2795 2766 2784 2758 2735 2714 2695 2677 2694 2678
PAF Base Steel ≥ 0.125" 2886 2903 2858 2819 2785 2755 2728 2748 2724 2702 2683 2665 2649 2667 2652
#12 Screw Base Steel ≥ .0385" 2885 2902 2857 2818 2784 2754 2727 2747 2723 2702 2682 2664 2648 2666 2651
D PANEL

Concrete + Deck = 44.7 psf Icr = 51.8 in4/ft Mno/Ω= 53.0 kip-in/ft Vn/Ω = 3.51 kip/ft
(Icr+Iu)/2 = 72.1 in4/ft Iu = 92.4 in4/ft ϕMno= 81.0 kip-in/ft ϕ Vn = 5.26 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3570 4920 5910 7710 10410
ACUSTADEK®

24 in o.c. 3570 4920 5910 7710 7750


36 in o.c. 3570 4920 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 89


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.215yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 3" 8' - 1" 8' - 7" 19 9' - 6" 10' - 9" 11' - 1"
21 8' - 2" 9' - 2" 9' - 6" 18 9' - 9" 11' - 6" 11' - 10"
20 8' - 8" 9' - 7" 9' - 10" 16 10' - 6" 13' - 2" 12' - 6"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 563 474 404 347 300 262 230 202 179 159 142 126 113 101 91
LRFD, ϕW 900 759 646 555 481 419 367 324 286 254 226 202 181 162 145
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3343 3316 3279 3246 3218 3193 3170 3161 3143 3126 3111 3097 3084 3080 3069
PAF Base Steel ≥ .25" 3095 3088 3066 3048 3032 3018 3005 3005 2994 2984 2976 2968 2960 2962 2955
PAF Base Steel ≥ 0.125" 3076 3070 3050 3033 3018 3004 2992 2993 2982 2973 2965 2958 2951 2952 2946
#12 Screw Base Steel ≥ .0385" 3058 3053 3034 3018 3004 2992 2980 2981 2972 2963 2955 2948 2942 2944 2938
Concrete + Deck = 49.2 psf Icr = 41.6 in4/ft Mno/Ω= 33.9 kip-in/ft Vn/Ω = 3.78 kip/ft
(Icr+Iu)/2 = 76.942 in4/ft Iu = 112.3 in4/ft ϕMno= 51.8 kip-in/ft ϕ Vn = 5.43 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 635 536 457 393 341 298 262 231 205 183 163 146 131 118 106
LRFD, ϕW 1017 858 731 629 546 477 419 370 328 292 261 234 210 189 170
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3422 3393 3350 3313 3280 3251 3225 3216 3194 3175 3157 3141 3127 3124 3111
PAF Base Steel ≥ .25" 3137 3131 3106 3085 3066 3050 3035 3036 3024 3012 3002 2993 2984 2987 2979
PAF Base Steel ≥ 0.125" 3116 3110 3087 3067 3050 3034 3021 3022 3010 3000 2990 2981 2973 2976 2969
#12 Screw Base Steel ≥ .0385" 3096 3093 3071 3052 3035 3021 3008 3010 2999 2989 2980 2971 2964 2967 2960
Concrete + Deck = 49.4 psf Icr = 45.8 in4/ft Mno/Ω= 38.0 kip-in/ft Vn/Ω = 4.03 kip/ft
(Icr+Iu)/2 = 79.985 in4/ft Iu = 114.1 in4/ft ϕMno= 58.1 kip-in/ft ϕ Vn = 6.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 671 566 483 416 361 316 278 245 218 194 174 156 140 126 114
LRFD, ϕW 1073 906 773 666 578 505 444 392 348 310 278 249 224 202 182
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3462 3433 3387 3347 3311 3281 3253 3244 3221 3200 3181 3164 3148 3146 3132
PAF Base Steel ≥ .25" 3159 3153 3126 3104 3084 3066 3051 3052 3039 3027 3016 3006 2997 3000 2992
PAF Base Steel ≥ 0.125" 3136 3131 3107 3085 3066 3050 3035 3038 3025 3014 3003 2994 2985 2989 2981
#12 Screw Base Steel ≥ .0385" 3116 3113 3090 3069 3052 3036 3022 3025 3013 3002 2992 2983 2975 2979 2972
Concrete + Deck = 49.5 psf Icr = 47.8 in4/ft Mno/Ω= 40.0 kip-in/ft Vn/Ω = 4.03 kip/ft
(Icr+Iu)/2 = 81.439 in4/ft Iu = 115.0 in4/ft ϕMno= 61.2 kip-in/ft ϕ Vn = 6.04 kip/ft

90 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.215yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 794 671 574 495 430 377 332 294 262 234 210 189 171 154 140
LRFD, ϕW 1271 1074 918 792 689 603 531 471 419 375 336 302 273 247 224
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 3606 3575 3518 3469 3426 3388 3354 3346 3318 3292 3269 3247 3228 3227 3209
PAF Base Steel ≥ .25" 3235 3233 3200 3172 3148 3126 3107 3112 3095 3080 3066 3054 3042 3049 3038
PAF Base Steel ≥ 0.125" 3208 3207 3177 3150 3127 3107 3088 3094 3079 3064 3051 3039 3029 3036 3026
#12 Screw Base Steel ≥ .0385" 3187 3188 3159 3133 3111 3092 3074 3081 3066 3052 3040 3028 3018 3025 3016
Concrete + Deck = 49.8 psf Icr = 54.6 in4/ft Mno/Ω= 47.0 kip-in/ft Vn/Ω = 4.03 kip/ft
(Icr+Iu)/2 =86.414in4/ft Iu = 118.2 in4/ft ϕMno= 71.8 kip-in/ft ϕ Vn = 6.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 878 742 635 548 477 419 369 328 292 261 235 212 191 173 157
LRFD, ϕW 1404 1188 1016 877 764 670 591 524 467 418 376 339 306 277 252
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3712 3681 3616 3560 3511 3467 3429 3422 3390 3360 3334 3309 3287 3288 3268
PAF Base Steel ≥ .25" 3292 3293 3256 3224 3196 3171 3149 3157 3138 3120 3105 3090 3077 3086 3074

N PANELS
PAF Base Steel ≥ 0.125" 3261 3265 3230 3199 3173 3149 3128 3138 3119 3103 3088 3074 3062 3071 3060
#12 Screw Base Steel ≥ .0385" 3240 3245 3211 3182 3156 3134 3114 3124 3106 3091 3076 3063 3051 3061 3050
Concrete + Deck = 50.1 psf Icr = 59.0 in4/ft Mno/Ω= 51.7 kip-in/ft Vn/Ω = 4.03 kip/ft
(Icr+Iu)/2 =89.703in4/ft Iu = 120.4 in4/ft ϕMno= 79.1 kip-in/ft ϕ Vn = 6.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1072 908 778 672 586 515 455 405 362 324 292 264 239 218 198

C PANELS
LRFD, ϕW 1715 1453 1244 1076 938 824 729 648 579 519 468 423 383 348 317
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3977 3948 3863 3789 3725 3669 3618 3617 3574 3536 3501 3468 3439 3445 3419
PAF Base Steel ≥ .25" 3434 3447 3398 3355 3318 3286 3257 3274 3249 3226 3205 3185 3168 3185 3169
PAF Base Steel ≥ 0.125" 3377 3394 3349 3309 3275 3245 3218 3238 3214 3193 3173 3155 3139 3157 3142
#12 Screw Base Steel ≥ .0385" 3375 3392 3347 3308 3274 3244 3217 3237 3214 3192 3173 3155 3138 3157 3142
D PANEL

Concrete + Deck = 50.7 psf Icr = 68.9 in4/ft Mno/Ω= 62.7 kip-in/ft Vn/Ω = 4.03 kip/ft
(Icr+Iu)/2 = 97.114 in4/ft Iu = 125.4 in4/ft ϕMno= 95.9 kip-in/ft ϕ Vn = 6.04 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 4070 5420 6410 8210 10910
ACUSTADEK®

24 in o.c. 4070 5420 6410 7750 7750


36 in o.c. 4070 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 91


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.370yd3/100ft2
1 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 0" 7' - 9" 8' - 3" 19 9' - 2" 10' - 4" 10' - 8"
21 7' - 10" 8' - 10" 9' - 1" 18 9' - 5" 11' - 0" 11' - 5"
20 8' - 3" 9' - 2" 9' - 6" 16 10' - 1" 12' - 8" 12' - 2"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 652 549 468 402 349 304 267 235 208 185 165 147 132 118 106
LRFD, ϕW 1043 879 749 644 558 486 427 376 333 296 264 236 211 189 170
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3834 3807 3769 3737 3708 3683 3661 3652 3633 3616 3601 3587 3575 3571 3560
PAF Base Steel ≥ .25" 3586 3578 3557 3539 3522 3508 3496 3495 3484 3475 3466 3458 3451 3452 3445
PAF Base Steel ≥ 0.125" 3567 3560 3540 3523 3508 3495 3483 3483 3473 3464 3456 3448 3441 3443 3437
#12 Screw Base Steel ≥ .0385" 3549 3544 3525 3509 3495 3482 3471 3472 3462 3454 3446 3439 3432 3434 3428
Concrete + Deck = 55.2 psf Icr = 53.4 in4/ft Mno/Ω= 39.1 kip-in/ft Vn/Ω = 4.06 kip/ft
(Icr+Iu)/2 = 101.21 in4/ft Iu = 149.0 in4/ft ϕMno= 59.9 kip-in/ft ϕ Vn = 5.84 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 736 621 530 456 396 346 304 269 238 212 190 170 153 138 124
LRFD, ϕW 1178 994 848 730 634 554 487 430 382 340 304 272 245 220 199
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3913 3884 3841 3803 3770 3741 3716 3706 3685 3666 3648 3632 3617 3614 3601
PAF Base Steel ≥ .25" 3628 3621 3597 3575 3557 3540 3526 3526 3514 3503 3493 3483 3475 3477 3470
PAF Base Steel ≥ 0.125" 3606 3601 3578 3558 3540 3525 3511 3513 3501 3490 3481 3472 3464 3467 3460
#12 Screw Base Steel ≥ .0385" 3587 3583 3561 3542 3526 3511 3498 3500 3489 3479 3470 3462 3454 3458 3451
Concrete + Deck = 55.4 psf Icr = 58.8 in4/ft Mno/Ω= 43.9 kip-in/ft Vn/Ω = 4.57 kip/ft
(Icr+Iu)/2 = 105.12 in4/ft Iu = 151.4 in4/ft ϕMno= 67.2 kip-in/ft ϕ Vn = 6.55 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 777 656 560 483 419 367 322 285 253 226 202 181 163 147 133
LRFD, ϕW 1244 1050 896 772 671 586 516 456 405 361 323 290 261 235 213
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3953 3923 3877 3837 3802 3771 3743 3734 3711 3691 3672 3655 3639 3636 3622
PAF Base Steel ≥ .25" 3649 3643 3617 3594 3574 2557 3541 3543 3529 3517 3506 3496 3487 3490 3482
PAF Base Steel ≥ 0.125" 3626 3622 3597 3576 3557 3540 3526 3528 3515 3504 3494 3484 3476 3479 3472
#12 Screw Base Steel ≥ .0385" 3606 3603 3580 3560 3542 3526 3513 3516 3504 3493 3483 3474 3466 3470 3462
Concrete + Deck = 55.5 psf Icr = 61.4 in4/ft Mno/Ω= 46.3 kip-in/ft Vn/Ω = 4.57 kip/ft
(Icr+Iu)/2 = 107 in4/ft Iu = 152.6 in4/ft ϕMno= 70.8 kip-in/ft ϕ Vn = 6.86 kip/ft

92 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
5 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.370yd3/100ft2
1 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 921 779 666 575 500 438 386 342 305 273 245 220 199 180 163
LRFD, ϕW 1474 1246 1065 919 800 701 618 548 488 436 392 353 318 288 261
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 4097 4065 4009 3959 3916 3878 3844 3836 3808 3782 3759 3738 3718 3717 3700
PAF Base Steel ≥ .25" 3726 3723 3691 3663 3638 3616 3597 3602 3586 3570 3557 3544 3533 3539 3529
PAF Base Steel ≥ 0.125" 3698 3698 3667 3641 3617 3597 3579 3585 3569 3555 3542 3530 3519 3526 3516
#12 Screw Base Steel ≥ .0385" 3677 3678 3649 3624 3602 3582 3565 3571 3556 3543 3530 3519 3508 3516 3506
Concrete + Deck = 55.9 psf Icr = 70.3 in4/ft Mno/Ω= 54.4 kip-in/ft Vn/Ω = 4.57 kip/ft
(Icr+Iu)/2 = 113.42 in4/ft Iu = 156.6 in4/ft ϕMno= 83.2 kip-in/ft ϕ Vn = 6.86 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1019 862 738 637 555 487 430 381 340 304 274 247 223 202 184
LRFD, ϕW 1631 1380 1180 1019 888 779 687 610 544 487 438 395 357 324 294
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 4202 4171 4106 4050 4001 3958 3919 3913 3880 3851 3824 3800 3778 3778 3758
PAF Base Steel ≥ .25" 3782 3783 3746 3714 3686 3661 3639 3647 3628 3611 3595 3581 3568 3577 3565

N PANELS
PAF Base Steel ≥ 0.125" 3752 3755 3720 3690 3663 3640 3619 3628 3610 3593 3578 3565 3552 3562 3550
#12 Screw Base Steel ≥ .0385" 3730 3735 3702 3672 3647 3624 3604 3614 3597 3581 3567 3553 3541 3552 3541
Concrete + Deck = 56.1 psf Icr = 76.0 in4/ft Mno/Ω= 59.9 kip-in/ft Vn/Ω = 4.57 kip/ft
(Icr+Iu)/2 = 117.68 in4/ft Iu = 159.3 in4/ft ϕMno= 91.7 kip-in/ft ϕ Vn = 6.86 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1247 1056 905 783 683 600 531 472 422 378 341 308 280 255 232

C PANELS
LRFD, ϕW 1995 1690 1448 1252 1092 960 849 755 675 606 546 494 448 407 371
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4467 4438 4353 4280 4216 4159 4109 4108 4065 4026 3991 3959 3929 3936 3910
PAF Base Steel ≥ .25" 3925 3937 3888 3846 3809 3776 3747 3765 3739 3716 3695 3676 3658 3675 3659
PAF Base Steel ≥ 0.125" 3867 3884 3839 3800 3766 3736 3709 3729 3705 3683 3664 3646 3629 3648 3633
#12 Screw Base Steel ≥ .0385" 3866 3883 3838 3799 3765 3735 3708 3728 3704 3682 3663 3645 3629 3647 3632
D PANEL

Concrete + Deck = 56.8 psf Icr = 88.9 in4/ft Mno/Ω= 72.8 kip-in/ft Vn/Ω = 4.57 kip/ft
(Icr+Iu)/2 =127.28in4/ft Iu = 165.7 in4/ft ϕMno= 111.4 kip-in/ft ϕ Vn = 6.86 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 5910 6900 8700 11400
ACUSTADEK®

24 in o.c. n/a 5910 6900 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 93


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


6 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.687yd3/100ft2
2 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 6' - 6" 7' - 4" 7' - 8" 19 8' - 7" 9' - 7" 9' - 11"
21 7' - 4" 8' - 2" 8' - 6" 18 8' - 10" 10' - 3" 10' - 8"
20 7' - 8" 8' - 6" 8' - 10" 16 9' - 6" 11' - 10" 11' - 7"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 836 705 601 517 448 391 343 303 269 239 213 191 171 154 138
LRFD, ϕW 1337 1127 961 827 717 626 549 485 430 382 341 305 274 246 221
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 4814 4787 4750 4718 4689 4664 4642 4632 4614 4597 4582 4568 4555 4552 4541
PAF Base Steel ≥ .25" 4567 4559 4538 4519 4503 4489 4477 4476 4465 4456 4447 4439 4432 4433 4426
PAF Base Steel ≥ 0.125" 4547 4541 4521 4504 4489 4476 4464 4464 4454 4445 4436 4429 4422 4424 4417
#12 Screw Base Steel ≥ .0385" 4529 4524 4506 4490 4475 4463 4452 4452 4443 4434 4427 4419 4413 4415 4409
Concrete + Deck = 67.3 psf Icr = 82.0 in4/ft Mno/Ω= 50.0 kip-in/ft Vn/Ω = 4.64 kip/ft
(Icr+Iu)/2 = 164 in4/ft Iu = 245.9 in4/ft ϕMno= 76.6 kip-in/ft ϕ Vn = 6.71 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 945 798 681 587 509 446 392 347 308 275 246 220 198 179 161
LRFD, ϕW 1512 1277 1090 939 815 713 627 555 493 439 393 353 317 286 258
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 4893 4865 4821 4784 4751 4722 4696 4687 4666 4646 4629 4613 4598 4595 4582
PAF Base Steel ≥ .25" 4609 4602 4577 4556 4538 4521 4507 4507 4495 4484 4473 4464 4456 4458 4450
PAF Base Steel ≥ 0.125" 4587 4582 4559 4539 4521 4506 4492 4494 4482 4471 4462 4453 4445 4448 4440
#12 Screw Base Steel ≥ .0385" 4568 4564 4542 4523 4507 4492 4479 4481 4470 4460 4451 4443 4435 4438 4432
Concrete + Deck = 67.5 psf Icr = 90.6 in4/ft Mno/Ω= 56.2 kip-in/ft Vn/Ω = 5.16 kip/ft
(Icr+Iu)/2 = 170 in4/ft Iu = 249.5 in4/ft ϕMno= 86.0 kip-in/ft ϕ Vn = 7.42 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 999 843 720 621 540 472 416 368 327 292 262 235 212 191 173
LRFD, ϕW 1598 1349 1152 993 863 755 665 589 523 467 418 376 339 306 277
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 4934 4904 4858 4818 4783 4752 4724 4715 4692 4672 4653 4636 4620 4617 4603
PAF Base Steel ≥ .25" 4630 4624 4598 4575 4555 4538 4522 4524 4510 4498 4487 4477 4468 4471 4463
PAF Base Steel ≥ 0.125" 4607 4603 4578 4557 4538 4521 4507 4509 4496 4485 4475 4465 4456 4460 4452
#12 Screw Base Steel ≥ .0385" 4587 4584 4561 4541 4523 4507 4493 4496 4484 4474 4464 4455 4447 4451 4443
Concrete + Deck = 67.6 psf Icr = 94.7 in4/ft Mno/Ω= 59.3 kip-in/ft Vn/Ω = 5.45 kip/ft
(Icr+Iu)/2 = 173 in4/ft Iu = 251.2 in4/ft ϕMno= 90.7 kip-in/ft ϕ Vn = 7.81 kip/ft

94 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
6 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.987yd3/100ft2
2 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1186 1003 858 740 645 565 499 442 394 353 317 286 258 234 212
LRFD, ϕW 1897 1604 1372 1185 1031 904 798 708 631 565 507 457 413 374 340
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 5077 5046 4989 4940 4897 4859 4825 4817 4789 4763 4740 4719 4699 4698 4681
PAF Base Steel ≥ .25" 4707 4704 4672 4644 4619 4597 4578 4583 4566 4551 4538 4525 4514 4520 4510
PAF Base Steel ≥ 0.125" 4679 4679 4648 4622 4598 4578 4560 4566 4550 4536 4523 4511 4500 4507 4497
#12 Screw Base Steel ≥ .0385" 4658 4659 4630 4605 4582 4563 4546 4552 4537 4523 4511 4500 4489 4497 4487
Concrete + Deck = 68.0 psf Icr = 108.6 in4/ft Mno/Ω= 69.8 kip-in/ft Vn/Ω = 5.74 kip/ft
(Icr+Iu)/2 = 183 in4/ft Iu = 257.3 in4/ft ϕMno= 106.8 kip-in/ft ϕ Vn = 8.61 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1313 1111 951 822 716 629 555 493 440 394 355 320 290 263 239
LRFD, ϕW 2101 1778 1522 1315 1146 1006 888 789 704 631 568 512 464 421 383
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5183 5152 5087 5031 4982 4939 4900 4893 4861 4832 4805 4781 4758 4759 4739
PAF Base Steel ≥ .25" 4763 4764 4727 4695 4667 4642 4620 4628 4609 4592 4576 4562 4548 4558 4546

N PANELS
PAF Base Steel ≥ 0.125" 4733 4736 4701 4671 4644 4620 4600 4609 4591 4574 4559 4546 4533 4543 4531
#12 Screw Base Steel ≥ .0385" 4711 4716 4682 4653 4628 4605 4585 4595 4578 4562 4547 4534 4522 4532 4521
Concrete + Deck = 68.2 psf Icr = 117.7 in4/ft Mno/Ω= 77.1 kip-in/ft Vn/Ω = 5.74 kip/ft
(Icr+Iu)/2 = 190 in4/ft Iu = 261.5 in4/ft ϕMno= 117.9 kip-in/ft ϕ Vn = 8.61 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1611 1365 1170 1013 884 777 687 612 547 491 443 401 364 332 303

C PANELS
LRFD, ϕW 2578 2185 1872 1620 1414 1243 1100 979 875 786 709 642 583 530 484
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 5448 5419 5334 5261 5197 5140 5090 5088 5046 5007 4972 4940 4910 4917 4890
PAF Base Steel ≥ .25" 4905 4918 4869 4827 4790 4757 4728 4746 4720 4697 4676 4657 4639 4656 4640
PAF Base Steel ≥ 0.125" 4848 4865 4820 4781 4747 4716 4690 4710 4686 4664 4645 4627 4610 4629 4613
#12 Screw Base Steel ≥ .0385" 4847 4864 4819 4780 4745 4715 4689 4709 4685 4663 4644 4626 4610 4628 4613
D PANEL

Concrete + Deck = 68.8 psf Icr = 138.2 in4/ft Mno/Ω= 93.9 kip-in/ft Vn/Ω = 5.74 kip/ft
(Icr+Iu)/2 = 205 in4/ft Iu = 271.2 in4/ft ϕMno= 143.7 kip-in/ft ϕ Vn = 8.61 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 6890 7880 9680 12380
ACUSTADEK®

24 in o.c. n/a 6890 7750 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 95


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


7 1⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.910yd3/100ft2
3 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 6' - 3" 7' - 0" 7' - 3" 19 8' - 3" 9' - 2" 9' - 5"
21 7' - 0" 7' - 10" 8' - 1" 18 8' - 6" 9' - 10" 10' - 2"
20 7' - 4" 8' - 2" 8' - 5" 16 9' - 2" 11' - 3" 11' - 3"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 978 824 703 605 525 458 403 356 315 281 251 224 201 181 163
LRFD, ϕW 1564 1319 1125 968 840 733 644 569 504 449 401 359 322 290 261
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 5550 5523 5486 5453 5425 5400 5377 5368 5350 5333 5318 5304 5291 5287 5276
PAF Base Steel ≥ .25" 5302 5294 5273 5255 5239 5225 5212 5212 5201 5191 5183 5175 5167 5169 5162
PAF Base Steel ≥ 0.125" 5283 5277 5257 5240 5225 5211 5199 5199 5189 5180 5172 5164 5158 5159 5153
#12 Screw Base Steel ≥ .0385" 5265 5260 5241 5225 5211 5199 5187 5188 5179 5170 5162 5155 5149 5151 5145
Concrete + Deck = 76.3 psf Icr = 108.0 in4/ft Mno/Ω= 58.4 kip-in/ft Vn/Ω = 5.11 kip/ft
(Icr+Iu)/2 = 225 in4/ft Iu = 342.0 in4/ft ϕMno= 89.4 kip-in/ft ϕ Vn = 7.42 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1106 934 797 687 597 522 460 407 361 323 289 259 233 211 190
LRFD, ϕW 1770 1494 1276 1100 955 836 736 651 578 516 462 415 374 337 305
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 5629 5600 5557 5520 5487 5458 5432 5423 5401 5382 5364 5348 5334 5330 5318
PAF Base Steel ≥ .25" 5344 5338 5313 5292 5273 5257 5242 5243 5231 5219 5209 5200 5191 5194 5186
PAF Base Steel ≥ 0.125" 5322 5317 5294 5274 5257 5241 5228 5229 5217 5207 5197 5188 5180 5183 5176
#12 Screw Base Steel ≥ .0385" 5303 5300 5278 5259 5242 5228 5215 5217 5206 5196 5187 5178 5171 5174 5167
Concrete + Deck = 76.6 psf Icr = 119.4 in4/ft Mno/Ω= 65.7 kip-in/ft Vn/Ω = 5.63 kip/ft
(Icr+Iu)/2 = 233 in4/ft Iu = 346.6 in4/ft ϕMno= 100.5 kip-in/ft ϕ Vn = 8.13 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1169 988 844 728 632 554 488 432 384 343 307 276 249 225 204
LRFD, ϕW 1871 1580 1350 1164 1012 886 780 691 615 549 492 442 399 360 326
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 5669 5640 5594 5553 5518 5487 5460 5451 5428 5407 5388 5371 5355 5353 5339
PAF Base Steel ≥ .25" 5366 5360 5333 5311 5291 5273 5258 5259 5246 5234 5223 5213 5204 5207 5199
PAF Base Steel ≥ 0.125" 5343 5338 5314 5292 5273 5257 5242 5245 5232 5221 5210 5201 5192 5196 5188
#12 Screw Base Steel ≥ .0385" 5323 5320 5297 5276 5259 5243 5229 5232 5220 5209 5199 5190 5182 5186 5179
Concrete + Deck = 76.7 psf Icr = 124.9 in4/ft Mno/Ω= 69.3 kip-in/ft Vn/Ω = 5.92 kip/ft
(Icr+Iu)/2 = 237 in4/ft Iu = 348.9 in4/ft ϕMno= 106.0 kip-in/ft ϕ Vn = 8.52 kip/ft

96 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
7 1⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.910yd3/100ft2
3 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1390 1176 1006 869 756 663 586 520 463 415 373 336 304 276 251
LRFD, ϕW 2223 1881 1609 1390 1210 1062 937 831 741 664 597 538 487 441 401
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 5813 5782 5725 5676 5633 5595 5561 5553 5524 5499 5475 5454 5435 5434 5416
PAF Base Steel ≥ .25" 5442 5440 5407 5379 5355 5333 5314 5319 5302 5287 5273 5261 5249 5256 5245
PAF Base Steel ≥ 0.125" 5415 5414 5384 5357 5334 5314 5295 5301 5286 5271 5258 5246 5236 5242 5233
#12 Screw Base Steel ≥ .0385" 5394 5395 5366 5340 5318 5299 5281 5288 5273 5259 5247 5235 5225 5232 5223
Concrete + Deck = 77.0 psf Icr = 143.6 in4/ft Mno/Ω= 81.7 kip-in/ft Vn/Ω = 6.68 kip/ft
(Icr+Iu)/2 = 250 in4/ft Iu = 356.9 in4/ft ϕMno= 125.1 kip-in/ft ϕ Vn = 9.59 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1540 1304 1116 965 841 739 652 580 517 464 418 377 342 310 283
LRFD, ϕW 2465 2086 1786 1544 1346 1182 1044 927 828 742 668 603 547 497 452
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5919 5888 5823 5767 5718 5674 5636 5629 5597 5567 5541 5516 5494 5495 5475
PAF Base Steel ≥ .25" 5499 5500 5463 5431 5403 5378 5356 5364 5345 5327 5312 5297 5284 5293 5281

N PANELS
PAF Base Steel ≥ 0.125" 5468 5472 5437 5406 5380 5356 5335 5345 5326 5310 5295 5281 5269 5278 5267
#12 Screw Base Steel ≥ .0385" 5447 5452 5418 5389 5363 5341 5321 5331 5313 5298 5283 5270 5258 5268 5257
Concrete + Deck = 77.3 psf Icr = 155.9 in4/ft Mno/Ω= 90.3 kip-in/ft Vn/Ω = 6.68 kip/ft
(Icr+Iu)/2 = 259 in4/ft Iu = 362.3 in4/ft ϕMno= 138.1 kip-in/ft ϕ Vn = 10.02 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1894 1605 1376 1191 1040 914 809 720 644 579 522 473 430 391 357

C PANELS
LRFD, ϕW 3030 2568 2201 1905 1663 1463 1295 1152 1031 926 836 757 687 626 572
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 6184 6154 6070 5996 5932 5876 5825 5824 5781 5743 5707 5675 5646 5652 5626
PAF Base Steel ≥ .25" 5641 5654 5605 5562 5525 5493 5463 5481 5456 5433 5412 5392 5375 5392 5376
PAF Base Steel ≥ 0.125" 5584 5601 5556 5516 5482 5452 5425 5445 5421 5400 5380 5362 5346 5364 5349
#12 Screw Base Steel ≥ .0385" 5582 5599 5554 5515 5481 5451 5424 5444 5420 5399 5379 5362 5345 5364 5348
D PANEL

Concrete + Deck = 77.9 psf Icr = 183.6 in4/ft Mno/Ω= 110.2 kip-in/ft Vn/Ω = 6.68 kip/ft
(Icr+Iu)/2 = 279 in4/ft Iu = 375.1 in4/ft ϕMno= 168.6 kip-in/ft ϕ Vn = 10.02 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 7630 8620 10420 13120
ACUSTADEK®

24 in o.c. n/a 7630 7750 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 97


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 0.907yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 8' - 8" 9' - 4" 10' - 4" 19 11' - 4" 12' - 9" 13' - 3"
21 9' - 10" 10' - 9" 11' - 4" 18 11' - 7" 13' - 8" 13' - 6"
20 10' - 5" 11' - 5" 11' - 9" 16 12' - 1" 15' - 1" 14' - 2"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 383 323 275 237 206 180 158 140 124 111 99 89 80 72 65
LRFD, ϕW 612 517 441 379 329 288 253 224 198 177 158 142 127 115 103
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 1748 1721 1684 1651 1623 1598 1575 1566 1548 1531 1516 1502 1489 1485 1474
PAF Base Steel ≥ .25" 1500 1492 1471 1453 1437 1423 1410 1410 1399 1389 1380 1372 1365 1366 1360
PAF Base Steel ≥ 0.125" 1481 1475 1455 1438 1422 1409 1397 1397 1387 1378 1370 1362 1355 1357 1351
#12 Screw Base Steel ≥ .0385" 1463 1458 1439 1423 1409 1396 1385 1386 1377 1368 1360 1353 1347 1349 1343
Concrete + Deck = 28.5 psf Icr = 31.2 in4/ft Mno/Ω= 22.8 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 46.8 in4/ft Iu = 62.4 in4/ft ϕMno= 34.9 kip-in/ft ϕ Vn = 4.10 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 430 363 310 267 232 203 179 159 141 126 113 100 88 78 69
LRFD, ϕW 688 581 496 428 372 325 287 254 226 201 180 162 146 132 119
L/360 - - - - - - - - - - - 100 88 78 69
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 1828 1800 1756 1719 1686 1657 1631 1622 1601 1581 1564 1548 1533 1530 1517
PAF Base Steel ≥ .25" 1544 1537 1512 1491 1472 1456 1442 1442 1430 1419 1408 1399 1390 1393 1385
PAF Base Steel ≥ 0.125" 1522 1517 1494 1474 1456 1441 1427 1428 1417 1406 1396 1388 1380 1383 1375
#12 Screw Base Steel ≥ .0385" 1502 1499 1477 1458 1442 1427 1414 1416 1405 1395 1386 1378 1370 1373 1366
Concrete + Deck = 28.7 psf Icr = 34.1 in4/ft Mno/Ω= 25.5 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 49 in4/ft Iu = 64.0 in4/ft ϕMno= 39.0 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 453 382 327 282 245 215 189 168 149 133 116 102 90 79 70
LRFD, ϕW 724 612 523 451 392 344 303 268 239 213 191 172 155 140 127
L/360 - - - - - - - - - - 116 102 90 79 70
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 1869 1840 1793 1753 1718 1687 1660 1651 1628 1607 1588 1571 1555 1553 1539
PAF Base Steel ≥ .25" 1566 1560 1533 1511 1491 1473 1458 1459 1446 1434 1423 1413 1404 1407 1399
PAF Base Steel ≥ 0.125" 1542 1538 1513 1492 1473 1457 1442 1444 1432 1420 1410 1401 1392 1396 1388
#12 Screw Base Steel ≥ .0385" 1523 1520 1496 1476 1458 1443 1429 1432 1420 1409 1399 1390 1382 1386 1379
Concrete + Deck = 28.8 psf Icr = 35.5 in4/ft Mno/Ω= 26.8 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 50.1 in4/ft Iu = 64.7 in4/ft ϕMno= 41.0 kip-in/ft ϕ Vn = 4.52 kip/ft

98 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 2.3

GENERAL INFORMATION
4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 0.907yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 532 450 385 333 290 254 224 193 166 143 125 109 96 85 75
LRFD, ϕW 851 720 616 532 463 407 359 318 284 254 229 206 187 169 154
L/360 - - - - - - - 193 166 143 125 109 96 85 75
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2015 1984 1927 1878 1835 1797 1763 1755 1727 1701 1678 1656 1637 1636 1619
PAF Base Steel ≥ .25" 1645 1642 1610 1582 1557 1535 1516 1521 1504 1489 1476 1463 1452 1458 1448
PAF Base Steel ≥ 0.125" 1617 1617 1586 1559 1536 1516 1498 1504 1488 1473 1461 1449 1438 1445 1435
#12 Screw Base Steel ≥ .0385" 1596 1597 1568 1543 1520 1501 1483 1490 1475 1461 1449 1438 1427 1435 1425
Concrete + Deck = 29.2 psf Icr = 40.1 in4/ft Mno/Ω= 31.3 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 53.7 in4/ft Iu = 67.3 in4/ft ϕMno= 47.9 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 585 495 424 367 320 281 237 202 173 150 130 114 100 89 79
LRFD, ϕW 936 793 679 587 511 449 397 352 314 282 254 229 208 189 172
L/360 - - - - - - 237 202 173 150 130 114 100 89 79
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2123 2091 2027 1971 1921 1878 1840 1833 1801 1771 1745 1720 1698 1699 1679
PAF Base Steel ≥ .25" 1703 1704 1667 1635 1607 1582 1560 1568 1549 1531 1516 1501 1488 1497 1485

N PANELS
PAF Base Steel ≥ 0.125" 1672 1675 1640 1610 1583 1560 1539 1548 1530 1514 1499 1485 1473 1482 1471
#12 Screw Base Steel ≥ .0385" 1651 1656 1622 1593 1567 1545 1525 1535 1517 1501 1487 1474 1462 1472 1461
Concrete + Deck = 29.4 psf Icr = 43.0 in4/ft Mno/Ω= 34.3 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 56 in4/ft Iu = 69.0 in4/ft ϕMno= 52.5 kip-in/ft ϕ Vn = 4.52 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 708 600 514 445 370 308 260 221 189 164 142 124 110 97 86

C PANELS
LRFD, ϕW 1133 960 822 712 621 546 483 430 385 346 312 282 256 233 213
L/360 - - - - 370 308 260 221 189 164 142 124 110 97 86
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2392 2362 2278 2204 2140 2083 2033 2032 1989 1951 1915 1883 1854 1860 1834
PAF Base Steel ≥ .25" 1849 1862 1813 1770 1733 1700 1671 1689 1664 1641 1619 1600 1583 1600 1584
PAF Base Steel ≥ 0.125" 1792 1809 1763 1724 1690 1660 1633 1653 1629 1608 1588 1570 1554 1572 1557
#12 Screw Base Steel ≥ .0385" 1790 1807 1762 1723 1689 1659 1632 1652 1628 1607 1587 1570 1553 1572 1556
D PANEL

Concrete + Deck = 30.1 psf Icr = 49.5 in4/ft Mno/Ω= 41.2 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 61.3 in4/ft Iu = 73.0 in4/ft ϕMno= 63.1 kip-in/ft ϕ Vn = 4.52 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 2620 3970 4960 6760 9460
ACUSTADEK®

24 in o.c. 2620 3970 4960 6760 7750


36 in o.c. 2620 3970 4960 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 99


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


4 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.061yd3/100ft2
1 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 8' - 4" 9' - 0" 9' - 10" 19 10' - 10" 12' - 3" 12' - 8"
21 9' - 5" 10' - 4" 10' - 10" 18 11' - 2" 13' - 1" 13' - 1"
20 9' - 11" 10' - 11" 11' - 3" 16 11' - 9" 14' - 7" 13' - 9"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 463 391 333 287 250 218 192 170 151 134 120 108 97 88 79
LRFD, ϕW 741 625 534 460 399 349 307 272 241 215 192 173 155 140 127
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2072 2045 2008 1975 1947 1922 1899 1890 1872 1855 1840 1826 1813 1809 1798
PAF Base Steel ≥ .25" 1824 1816 1795 1777 1761 1747 1734 1734 1723 1713 1705 1697 1689 1691 1684
PAF Base Steel ≥ 0.125" 1805 1799 1779 1762 1746 1733 1721 1721 1711 1702 1694 1686 1680 1681 1675
#12 Screw Base Steel ≥ .0385" 1787 1782 1763 1747 1733 1721 1709 1710 1701 1692 1684 1677 1671 1673 1667
Concrete + Deck = 33.1 psf Icr = 42.7 in4/ft Mno/Ω= 27.5 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 65.2 in4/ft Iu = 87.7 in4/ft ϕMno= 42.1 kip-in/ft ϕ Vn = 4.38 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 520 440 376 324 282 247 217 193 171 153 137 123 111 101 91
LRFD, ϕW 833 703 601 518 451 395 348 308 274 245 220 198 178 161 146
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2152 2124 2080 2043 2010 1981 1955 1946 1925 1905 1888 1872 1857 1854 1841
PAF Base Steel ≥ .25" 1868 1861 1836 1815 1797 1780 1766 1766 1754 1743 1732 1723 1715 1717 1709
PAF Base Steel ≥ 0.125" 1846 1841 1818 1798 1780 1765 1751 1752 1741 1730 1720 1712 1704 1707 1699
#12 Screw Base Steel ≥ .0385" 1826 1823 1801 1782 1766 1751 1738 1740 1729 1719 1710 1702 1694 1697 1690
Concrete + Deck = 33.3 psf Icr = 46.8 in4/ft Mno/Ω= 30.8 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 68.3 in4/ft Iu = 89.8 in4/ft ϕMno= 47.1 kip-in/ft ϕ Vn = 5.09 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 548 463 396 342 297 260 230 204 181 162 145 131 118 107 97
LRFD, ϕW 877 741 634 547 476 417 367 326 290 259 233 210 189 171 155
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2193 2164 2118 2077 2042 2011 1984 1975 1952 1931 1912 1895 1879 1877 1863
PAF Base Steel ≥ .25" 1890 1884 1857 1835 1815 1797 1782 1783 1770 1758 1747 1737 1728 1731 1723
PAF Base Steel ≥ 0.125" 1867 1862 1838 1816 1797 1781 1766 1769 1756 1745 1734 1725 1716 1720 1712
#12 Screw Base Steel ≥ .0385" 1847 1844 1821 1800 1783 1767 1753 1756 1744 1733 1723 1714 1706 1710 1703
Concrete + Deck = 33.4 psf Icr = 48.6 in4/ft Mno/Ω= 32.4 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 69.7 in4/ft Iu = 90.7 in4/ft ϕMno= 49.5 kip-in/ft ϕ Vn = 5.26 kip/ft

100 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
4 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.061yd3/100ft2
1 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 645 545 467 403 351 308 272 242 216 193 173 151 133 118 105
LRFD, ϕW 1031 873 747 645 562 494 436 387 345 309 278 251 227 206 188
L/360 - - - - - - - - - - 173 151 133 118 105
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2339 2308 2251 2202 2159 2121 2087 2079 2051 2025 2002 1980 1961 1960 1943
PAF Base Steel ≥ .25" 1969 1966 1934 1906 1881 1859 1840 1845 1828 1813 1800 1787 1776 1782 1772
PAF Base Steel ≥ 0.125" 1941 1941 1910 1884 1860 1840 1822 1828 1812 1798 1785 1773 1762 1769 1759
#12 Screw Base Steel ≥ .0385" 1920 1921 1892 1867 1844 1825 1807 1814 1799 1785 1773 1762 1751 1759 1749
Concrete + Deck = 33.8 psf Icr = 55.0 in4/ft Mno/Ω= 37.8 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 74.6 in4/ft Iu = 94.2 in4/ft ϕMno= 57.9 kip-in/ft ϕ Vn = 5.26 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 710 601 515 445 388 341 301 268 239 208 181 158 139 123 109
LRFD, ϕW 1135 961 823 712 621 545 482 428 383 343 309 279 253 230 210
L/360 - - - - - - - - - 208 181 158 139 123 109
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2447 2415 2351 2295 2245 2202 2164 2157 2125 2095 2069 2044 2022 2023 2003
PAF Base Steel ≥ .25" 2027 2028 1991 1959 1931 1906 1884 1892 1873 1855 1840 1825 1812 1821 1809

N PANELS
PAF Base Steel ≥ 0.125" 1996 2000 1964 1934 1908 1884 1863 1872 1854 1838 1823 1809 1797 1806 1795
#12 Screw Base Steel ≥ .0385" 1975 1980 1946 1917 1891 1869 1849 1859 1841 1826 1811 1798 1786 1796 1785
Concrete + Deck = 34.0 psf Icr = 59.0 in4/ft Mno/Ω= 41.5 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 77.8 in4/ft Iu = 96.5 in4/ft ϕMno= 63.5 kip-in/ft ϕ Vn = 5.26 kip/ft
Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 859 728 624 541 472 415 360 306 262 227 197 172 152 134 119

C PANELS
LRFD, ϕW 1375 1165 999 865 755 664 588 523 468 421 380 344 313 285 260
L/360 - - - - - - 360 306 262 227 197 172 152 134 119
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2716 2686 2602 2528 2464 2408 2357 2356 2313 2275 2239 2207 2178 2184 2158
PAF Base Steel ≥ .25" 2173 2186 2137 2094 2057 2025 1995 2013 1988 1965 1944 1924 1907 1924 1908
PAF Base Steel ≥ 0.125" 2116 2133 2087 2048 2014 1984 1957 1977 1953 1932 1912 1894 1878 1896 1881
#12 Screw Base Steel ≥ .0385" 2114 2131 2086 2047 2013 1983 1956 1976 1952 1931 1911 1894 1877 1896 1880
D PANEL

Concrete + Deck = 34.6 psf Icr = 68.0 in4/ft Mno/Ω= 50.0 kip-in/ft Vn/Ω = 2.63 kip/ft
(Icr+Iu)/2 = 84.9 in4/ft Iu = 101.8 in4/ft ϕMno= 76.5 kip-in/ft ϕ Vn = 5.26 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 2990 4340 5330 7130 9830
ACUSTADEK®

24 in o.c. 2990 4340 5330 7130 7750


36 in o.c. 2990 4340 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 101


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.125yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 8' - 0" 8' - 9" 9' - 5" 19 10' - 5" 11' - 9" 12' - 2"
21 9' - 0" 10' - 0" 10' - 5" 18 10' - 8" 12' - 7" 12' - 8"
20 9' - 6" 10' - 6" 10' - 10" 16 11' - 5" 14' - 2" 13' - 4"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 548 462 395 340 296 259 228 201 179 160 143 128 116 104 94
LRFD, ϕW 876 740 632 544 473 414 364 322 286 256 229 206 185 167 151
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2396 2369 2332 2299 2271 2246 2223 2214 2196 2179 2164 2150 2137 2133 2122
PAF Base Steel ≥ .25" 2148 2141 2119 2101 2085 2071 2058 2058 2047 2037 2029 2021 2013 2015 2008
PAF Base Steel ≥ 0.125" 2129 2123 2103 2086 2071 2057 2045 2045 2035 2026 2018 2011 2004 2005 1999
#12 Screw Base Steel ≥ .0385" 2111 2106 2087 2071 2057 2045 2033 2034 2025 2016 2008 2001 1995 1997 1991
Concrete + Deck = 37.7 psf Icr = 56.6 in4/ft Mno/Ω= 32.5 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 87.9 in4/ft Iu = 119.3 in4/ft ϕMno= 49.8 kip-in/ft ϕ Vn = 4.67 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 616 521 445 384 334 293 258 229 204 182 163 147 133 120 109
LRFD, ϕW 985 833 712 614 534 468 413 366 326 291 261 235 212 192 174
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2476 2448 2404 2367 2334 2305 2279 2270 2249 2229 2212 2196 2181 2178 2165
PAF Base Steel ≥ .25" 2192 2185 2160 2139 2121 2104 2090 2090 2078 2067 2056 2047 2039 2041 2034
PAF Base Steel ≥ 0.125" 2170 2165 2142 2122 2104 2089 2075 2077 2065 2054 2045 2036 2028 2031 2023
#12 Screw Base Steel ≥ .0385" 2151 2147 2125 2106 2090 2075 2062 2064 2053 2043 2034 2026 2018 2021 2015
Concrete + Deck = 37.9 psf Icr = 62.0 in4/ft Mno/Ω= 36.4 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 92 in4/ft Iu = 122.0 in4/ft ϕMno= 55.7 kip-in/ft ϕ Vn = 5.38 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 649 549 469 405 353 309 273 242 215 193 173 156 141 128 116
LRFD, ϕW 1038 878 751 648 564 494 436 387 345 308 277 249 225 204 185
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2517 2488 2442 2402 2366 2336 2308 2299 2276 2255 2236 2219 2203 2201 2187
PAF Base Steel ≥ .25" 2214 2208 2181 2159 2139 2121 2106 2107 2094 2082 2071 2061 2052 2055 2047
PAF Base Steel ≥ 0.125" 2191 2186 2162 2140 2121 2105 2090 2093 2080 2069 2058 2049 2040 2044 2036
#12 Screw Base Steel ≥ .0385" 2171 2168 2145 2124 2107 2091 2077 2080 2068 2057 2047 2038 2030 2034 2027
Concrete + Deck = 38.0 psf Icr = 64.5 in4/ft Mno/Ω= 38.3 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 93.9 in4/ft Iu = 123.2 in4/ft ϕMno= 58.5 kip-in/ft ϕ Vn = 5.77 kip/ft

102 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
5" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.125yd3/100ft2

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 764 647 554 479 417 366 324 288 257 230 207 187 169 154 140
LRFD, ϕW 1223 1035 886 766 668 586 518 460 411 368 331 299 271 246 224
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2663 2632 2575 2526 2483 2445 2411 2403 2375 2349 2326 2305 2285 2284 2267
PAF Base Steel ≥ .25" 2293 2290 2258 2230 2205 2183 2164 2169 2152 2137 2124 2111 2100 2106 2096
PAF Base Steel ≥ 0.125" 2265 2265 2234 2208 2184 2164 2146 2152 2136 2122 2109 2097 2086 2093 2083
#12 Screw Base Steel ≥ .0385" 2244 2245 2216 2191 2168 2149 2132 2138 2123 2110 2097 2086 2075 2083 2073
Concrete + Deck = 38.3 psf Icr = 73.0 in4/ft Mno/Ω= 44.8 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 100 in4/ft Iu = 127.7 in4/ft ϕMno= 68.5 kip-in/ft ϕ Vn = 6.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 842 713 611 528 461 405 358 318 285 255 230 208 187 165 147
LRFD, ϕW 1347 1141 977 845 737 648 573 509 455 409 368 333 302 275 250
L/360 - - - - - - - - - - - - 187 165 147
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2771 2740 2675 2619 2570 2526 2488 2481 2449 2419 2393 2368 2346 2347 2327
PAF Base Steel ≥ .25" 2351 2352 2315 2283 2255 2230 2208 2216 2197 2179 2164 2149 2136 2145 2133

N PANELS
PAF Base Steel ≥ 0.125" 2320 2324 2289 2258 2232 2208 2187 2197 2178 2162 2147 2133 2121 2130 2119
#12 Screw Base Steel ≥ .0385" 2299 2304 2270 2241 2215 2193 2173 2183 2165 2150 2135 2122 2110 2120 2109
Concrete + Deck = 38.6 psf Icr = 78.5 in4/ft Mno/Ω= 49.2 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 105 in4/ft Iu = 130.7 in4/ft ϕMno= 75.2 kip-in/ft ϕ Vn = 6.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1007 866 743 643 562 494 438 390 349 304 265 232 204 180 160

C PANELS
LRFD, ϕW 1634 1386 1188 1029 899 791 700 624 558 502 453 411 373 340 311
L/360 - - - - - - - - - 304 265 232 204 180 160
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3040 3010 2926 2852 2788 2732 2681 2680 2637 2599 2564 2531 2502 2508 2482
PAF Base Steel ≥ .25" 2497 2510 2461 2418 2381 2349 2319 2337 2312 2289 2268 2248 2231 2248 2232
PAF Base Steel ≥ 0.125" 2440 2457 2412 2372 2338 2308 2281 2301 2277 2256 2236 2218 2202 2220 2205
#12 Screw Base Steel ≥ .0385" 2438 2455 2410 2371 2337 2307 2280 2300 2277 2255 2235 2218 2201 2220 2204
D PANEL

Concrete + Deck = 39.2 psf Icr = 90.5 in4/ft Mno/Ω= 59.3 kip-in/ft Vn/Ω = 3.02 kip/ft
(Icr+Iu)/2 = 114 in4/ft Iu = 137.6 in4/ft ϕMno= 90.8 kip-in/ft ϕ Vn = 6.04 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3360 4710 5700 7500 10200
ACUSTADEK®

24 in o.c. 3360 4710 5700 7500 7750


36 in o.c. 3360 4710 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 103


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5 1⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.392yd3/100ft2
2 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 10" 8' - 7" 9' - 3" 19 10' - 3" 11' - 7" 11' - 11"
21 8' - 10" 9' - 10" 10' - 3" 18 10' - 6" 12' - 5" 12' - 6"
20 9' - 4" 10' - 4" 10' - 8" 16 11' - 3" 14' - 0" 13' - 2"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 591 499 426 368 319 280 246 218 194 173 155 139 125 113 102
LRFD, ϕW 946 799 682 588 511 447 394 348 310 277 248 223 201 181 164
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2558 2531 2494 2461 2433 2408 2385 2376 2358 2341 2326 2312 2299 2295 2284
PAF Base Steel ≥ .25" 2310 2303 2281 2263 2247 2233 2220 2220 2209 2199 2191 2183 2175 2177 2170
PAF Base Steel ≥ 0.125" 2291 2285 2265 2248 2233 2219 2207 2207 2197 2188 2180 2173 2166 2167 2161
#12 Screw Base Steel ≥ .0385" 2273 2268 2249 2233 2219 2207 2195 2196 2187 2178 2170 2163 2157 2159 2153
Concrete + Deck = 40.0 psf Icr = 64.4 in4/ft Mno/Ω= 35.1 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 101 in4/ft Iu = 137.7 in4/ft ϕMno= 53.7 kip-in/ft ϕ Vn = 4.82 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 665 562 481 415 361 316 279 247 220 197 177 159 144 130 118
LRFD, ϕW 1064 900 769 664 578 506 446 396 352 315 283 255 230 208 189
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 2638 2610 2566 2529 2496 2467 2441 2432 2411 2391 2374 2358 2343 2340 2327
PAF Base Steel ≥ .25" 2354 2347 2322 2301 2283 2266 2252 2252 2240 2229 2218 2209 2201 2203 2196
PAF Base Steel ≥ 0.125" 2332 2327 2304 2284 2266 2251 2237 2239 2227 2216 2207 2198 2190 2193 2185
#12 Screw Base Steel ≥ .0385" 2313 2309 2287 2268 2252 2237 2224 2226 2215 2205 2196 2188 2180 2183 2177
Concrete + Deck = 40.2 psf Icr = 70.6 in4/ft Mno/Ω= 39.3 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 106 in4/ft Iu = 140.7 in4/ft ϕMno= 60.1 kip-in/ft ϕ Vn = 5.53 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 701 593 507 438 381 334 295 261 233 209 187 169 153 138 126
LRFD, ϕW 1122 949 811 700 610 535 472 418 373 334 300 270 244 221 201
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2679 2650 2604 2564 2528 2498 2470 2461 2438 2417 2398 2381 2365 2363 2349
PAF Base Steel ≥ .25" 2376 2370 2343 2321 2301 2283 2268 2269 2256 2244 2233 2223 2214 2217 2209
PAF Base Steel ≥ 0.125" 2353 2348 2324 2302 2283 2267 2252 2255 2242 2231 2220 2211 2202 2206 2198
#12 Screw Base Steel ≥ .0385" 2333 2330 2307 2286 2269 2253 2239 2242 2230 2219 2209 2200 2192 2196 2189
Concrete + Deck = 40.3 psf Icr = 73.5 in4/ft Mno/Ω= 41.3 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 108 in4/ft Iu = 142.2 in4/ft ϕMno= 63.2 kip-in/ft ϕ Vn = 5.92 kip/ft

104 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
5 1⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.292yd3/100ft2
2 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 826 699 599 518 451 396 350 311 278 249 224 203 184 167 152
LRFD, ϕW 1321 1119 958 828 722 634 560 498 445 399 359 324 294 267 243
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 2825 2794 2737 2688 2645 2607 2573 2565 2537 2511 2488 2467 2447 2446 2429
PAF Base Steel ≥ .25" 2455 2452 2420 2392 2367 2345 2326 2331 2314 2299 2286 2273 2262 2268 2258
PAF Base Steel ≥ 0.125" 2427 2427 2396 2370 2346 2326 2308 2314 2298 2284 2271 2259 2248 2255 2245
#12 Screw Base Steel ≥ .0385" 2406 2407 2378 2353 2331 2311 2294 2300 2285 2272 2259 2248 2237 2245 2235
Concrete + Deck = 40.6 psf Icr = 83.2 in4/ft Mno/Ω= 48.4 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 115 in4/ft Iu = 147.2 in4/ft ϕMno= 74.0 kip-in/ft ϕ Vn = 6.44 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 910 771 661 572 499 438 388 345 308 277 249 225 205 186 169
LRFD, ϕW 1457 1234 1057 915 798 701 620 552 493 443 399 361 327 298 272
L/360 - - - - - - - - - - - - - - 169
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2933 2902 2837 2781 2732 2688 2650 2643 2611 2581 2555 2530 2508 2509 2489
PAF Base Steel ≥ .25" 2513 2514 2477 2445 2417 2392 2370 2378 2359 2341 2326 2311 2298 2307 2295

N PANELS
PAF Base Steel ≥ 0.125" 2482 2486 2451 2420 2394 2370 2349 2359 2340 2324 2309 2295 2283 2292 2281
#12 Screw Base Steel ≥ .0385" 2461 2466 2432 2403 2377 2355 2335 2345 2327 2312 2297 2284 2272 2282 2271
Concrete + Deck = 40.9 psf Icr = 89.5 in4/ft Mno/Ω= 53.1 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 120 in4/ft Iu = 150.6 in4/ft ϕMno= 81.3 kip-in/ft ϕ Vn = 6.44 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1074 937 804 696 608 535 474 422 378 340 304 266 234 207 184

C PANELS
LRFD, ϕW 1769 1500 1286 1114 973 856 758 676 605 544 491 445 405 369 338
L/360 - - - - - - - - - - 304 266 234 207 184
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3202 3173 3088 3014 2950 2894 2843 2842 2799 2761 2726 2693 2664 2670 2644
PAF Base Steel ≥ .25" 2659 2672 2623 2580 2543 2511 2482 2499 2474 2451 2430 2410 2393 2410 2394
PAF Base Steel ≥ 0.125" 2602 2619 2574 2534 2500 2470 2443 2463 2439 2418 2398 2380 2364 2382 2367
#12 Screw Base Steel ≥ .0385" 2600 2617 2572 2533 2499 2469 2442 2462 2439 2417 2397 2380 2363 2382 2366
D PANEL

Concrete + Deck = 41.5 psf Icr = 103.3 in4/ft Mno/Ω= 64.2 kip-in/ft Vn/Ω = 3.22 kip/ft
(Icr+Iu)/2 = 131 in4/ft Iu = 158.4 in4/ft ϕMno= 98.2 kip-in/ft ϕ Vn = 6.44 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. 3550 4900 5890 7690 10390
ACUSTADEK®

24 in o.c. 3550 4900 5890 7690 7750


36 in o.c. 3550 4900 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 105


TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


6 3⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.582yd3/100ft2
3 Hour Fire Rating

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 7' - 4" 8' - 2" 8' - 8" 19 9' - 7" 10' - 10" 11' - 2"
21 8' - 3" 9' - 3" 9' - 7" 18 9' - 11" 11' - 7" 11' - 11"
20 8' - 9" 9' - 8" 10' - 0" 16 10' - 7" 13' - 4" 12' - 7"

GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 760 642 549 473 412 361 318 281 250 224 201 180 163 147 133
LRFD, ϕW 1216 1028 878 758 659 577 508 450 401 358 321 289 260 235 213
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3166 3139 3101 3069 3040 3015 2993 2984 2965 2949 2933 2919 2907 2903 2892
PAF Base Steel ≥ .25" 2918 2910 2889 2871 2855 2840 2828 2827 2817 2807 2798 2790 2783 2784 2778
PAF Base Steel ≥ 0.125" 2899 2892 2872 2855 2840 2827 2815 2815 2805 2796 2788 2780 2773 2775 2769
#12 Screw Base Steel ≥ .0385" 2881 2876 2857 2841 2827 2814 2803 2804 2794 2786 2778 2771 2764 2766 2760
Concrete + Deck = 48.6 psf Icr = 99.2 in4/ft Mno/Ω= 45.0 kip-in/ft Vn/Ω = 3.78 kip/ft
(Icr+Iu)/2 = 162 in4/ft Iu = 224.0 in4/ft ϕMno= 68.8 kip-in/ft ϕ Vn = 5.42 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 856 724 619 535 466 408 360 320 285 255 229 207 187 169 154
LRFD, ϕW 1370 1159 991 856 745 653 576 511 456 408 367 330 299 271 246
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
21
Arc Spot Weld 1/2" Effective Dia 3246 3217 3174 3137 3104 3075 3049 3040 3018 2999 2981 2965 2951 2947 2935
PAF Base Steel ≥ .25" 2961 2955 2930 2909 2890 2874 2859 2860 2848 2836 2826 2817 2808 2811 2803
PAF Base Steel ≥ 0.125" 2939 2934 2911 2891 2874 2858 2845 2846 2834 2824 2814 2805 2797 2800 2793
#12 Screw Base Steel ≥ .0385" 2920 2917 2895 2876 2859 2845 2832 2834 2823 2813 2804 2795 2788 2791 2784
Concrete + Deck = 48.8 psf Icr = 108.8 in4/ft Mno/Ω= 50.4 kip-in/ft Vn/Ω = 4.02 kip/ft
(Icr+Iu)/2 = 169 in4/ft Iu = 228.5 in4/ft ϕMno= 77.2 kip-in/ft ϕ Vn = 6.13 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 903 764 654 565 492 432 381 338 302 270 243 219 198 180 164
LRFD, ϕW 1445 1223 1046 904 787 691 610 541 483 432 389 351 317 288 262
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3287 3257 3211 3171 3136 3105 3078 3069 3046 3025 3006 2989 2973 2970 2956
PAF Base Steel ≥ .25" 2983 2977 2951 2928 2908 2891 2875 2877 2864 2851 2840 2830 2821 2825 2816
PAF Base Steel ≥ 0.125" 2960 2956 2931 2910 2891 2875 2860 2862 2850 2838 2828 2818 2810 2814 2806
#12 Screw Base Steel ≥ .0385" 2940 2938 2914 2894 2876 2861 2847 2850 2838 2827 2817 2808 2800 2804 2797
Concrete + Deck = 48.9 psf Icr = 113.4 in4/ft Mno/Ω= 53.1 kip-in/ft Vn/Ω = 4.02 kip/ft
(Icr+Iu)/2 = 172 in4/ft Iu = 230.7 in4/ft ϕMno= 81.2 kip-in/ft ϕ Vn = 6.52 kip/ft

106 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

2WH-36 Composite Deck 3.3

GENERAL INFORMATION
6 3⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.582yd3/100ft2
3 Hour Fire Rating

3W PANELS
GA Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1066 903 774 669 584 513 453 403 360 323 291 263 239 217 198
LRFD, ϕW 1706 1445 1238 1071 934 821 726 645 576 517 466 422 382 348 317
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

2W PANELS
19 Arc Spot Weld 1/2" Effective Dia 3433 3402 3345 3296 3253 3215 3181 3173 3144 3119 3095 3074 3055 3054 3036
PAF Base Steel ≥ .25" 3062 3060 3027 2999 2975 2953 2934 2939 2922 2907 2893 2881 2869 2876 2865
PAF Base Steel ≥ 0.125" 3035 3034 3004 2977 2954 2933 2915 2921 2905 2891 2878 2866 2856 2862 2853
#12 Screw Base Steel ≥ .0385" 3014 3015 2986 2960 2938 2919 2901 2908 2893 2879 2867 2855 2845 2852 2843
Concrete + Deck = 49.2 psf Icr = 128.9 in4/ft Mno/Ω= 62.3 kip-in/ft Vn/Ω = 4.02 kip/ft
(Icr+Iu)/2 = 184 in4/ft Iu = 238.4 in4/ft ϕMno= 95.3 kip-in/ft ϕ Vn = 7.59 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

B PANELS
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1177 998 855 740 646 568 503 447 400 359 324 293 266 243 222
LRFD, ϕW 1884 1596 1368 1184 1034 909 804 716 640 575 519 470 426 388 355
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3541 3509 3444 3388 3339 3296 3257 3251 3218 3189 3162 3138 3116 3116 3097
PAF Base Steel ≥ .25" 3121 3122 3084 3052 3024 2999 2977 2986 2966 2949 2933 2919 2906 2915 2903

N PANELS
PAF Base Steel ≥ 0.125" 3090 3093 3058 3028 3001 2978 2957 2966 2948 2932 2917 2903 2890 2900 2889
#12 Screw Base Steel ≥ .0385" 3068 3073 3040 3011 2985 2963 2943 2953 2935 2919 2905 2892 2880 2890 2879
Concrete + Deck = 49.5 psf Icr = 138.9 in4/ft Mno/Ω= 68.6 kip-in/ft Vn/Ω = 4.02 kip/ft
(Icr+Iu)/2 = 191 in4/ft Iu = 243.6 in4/ft ϕMno= 104.9 kip-in/ft ϕ Vn = 8.04 kip/ft

Vertical Load Span (in) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1341 1217 1044 905 790 696 617 550 492 443 400 363 330 302 276

C PANELS
LRFD, ϕW 2295 1947 1670 1447 1265 1113 987 879 788 709 641 581 529 483 442
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3809 3780 3695 3622 3558 3501 3451 3450 3407 3368 3333 3301 3272 3278 3252
PAF Base Steel ≥ .25" 3267 3279 3230 3188 3151 3118 3089 3107 3081 3058 3037 3018 3000 3018 3001
PAF Base Steel ≥ 0.125" 3209 3226 3181 3142 3108 3078 3051 3071 3047 3025 3006 2988 2972 2990 2975
#12 Screw Base Steel ≥ .0385" 3208 3225 3180 3141 3107 3077 3050 3070 3046 3025 3005 2987 2971 2989 2974
D PANEL

Concrete + Deck = 50.1 psf Icr = 161.0 in4/ft Mno/Ω= 83.1 kip-in/ft Vn/Ω = 4.02 kip/ft
(Icr+Iu)/2 = 208 in4/ft Iu = 255.5 in4/ft ϕMno= 127.2 kip-in/ft ϕ Vn = 8.04 kip/ft

LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
3/4" Welded Shear Studs
All Gages

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
12 in o.c. n/a 5590 6580 8380 11080
ACUSTADEK®

24 in o.c. n/a 5590 6580 7750 7750


36 in o.c. n/a 5170 5170 5170 5170

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 107


TABLE OF CONTENTS

4.1 BH-36

2-3/8” 3-5/8” 6” 1-3/4” 2-3/8” 3-5/8” 6”

1-1/2” 1-1/2”

1-3/4” 1-3/4”
36” 36”

BH-36 Profile BHN-36 Profile

36/4 Attachment Pattern

B Series Embossment
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
22 1.75 0.0299 50 65 0.514 0.200 0.94 0.213 0.625
20 2.09 0.0359 50 65 0.615 0.240 0.94 0.253 0.623
18 2.76 0.0478 50 65 0.814 0.313 0.95 0.330 0.619
16 3.43 0.0598 50 65 1.012 0.383 0.95 0.404 0.615

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending
Distance to Distance to Uniform Load Only
Section N.A. from Section N.A. from Moment of Moment of
Gage Area Modulus Bottom Modulus Bottom Inertia Inertia Id = (2Ie+Ig)/3
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
22 0.179 0.175 0.74 0.187 0.98 0.157 0.197 0.171 0.198
20 0.235 0.228 0.77 0.236 0.96 0.197 0.237 0.211 0.238
18 0.351 0.311 0.84 0.329 0.94 0.287 0.313 0.296 0.313
16 0.330 0.392 0.89 0.404 0.95 0.377 0.383 0.379 0.383

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 6" 1" 2" 4" 6"
End 772 960 1223 1223 1180 1469 1871 1871
22
Interior 1229 1482 1832 1832 1828 2204 2726 2726
End 1081 1336 1690 1690 1655 2045 2586 2586
20
Interior 1737 2078 2551 2551 2584 3091 3794 3794
End 1834 2239 2802 2802 2805 3425 4287 4287
18
Interior 2984 3525 4276 4276 4439 5243 6361 6361
End 2771 3351 4158 4158 4240 5127 6361 6361
16
Interior 4555 5329 6405 6405 6776 7927 9527 9527
Web Crippling Constraints h=1.32" r=0.125" θ=78.3º

108 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BHF-36 4.2

GENERAL INFORMATION
2-3/8” 3-5/8” 6”

1-1/2”

36/7
1-3/4”

36”
36/4 Attachment Pattern
BHF-36 Profile

3W PANELS
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 3.69 0.0359 / 0.036 50 65 1.040 0.460 0.58 0.462 0.665

2W PANELS
20/18 4.16 0.0359 / 0.047 50 65 1.179 0.499 0.52 0.471 0.651
20/16 4.68 0.0359 / 0.059 50 65 1.330 0.535 0.48 0.479 0.634
18/20 4.35 0.0478 / 0.036 50 65 1.231 0.564 0.65 0.601 0.677
18/18 4.83 0.0478 / 0.047 50 65 1.370 0.614 0.59 0.613 0.670
18/16 5.35 0.0478 / 0.059 50 65 1.521 0.661 0.55 0.624 0.659
16/20 5.03 0.0598 / 0.036 50 65 1.423 0.661 0.70 0.736 0.682
16/18 5.51 0.0598 / 0.047 50 65 1.562 0.721 0.65 0.752 0.679
16/16 6.03 0.0598 / 0.059 50 65 1.713 0.777 0.60 0.767 0.674

B PANELS
Effective Section Modulus at Fy
Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie + I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft

N PANELS
20/20 0.643 0.272 0.43 0.438 0.73 0.354 0.389 0.389 0.413
20/18 0.744 0.278 0.39 0.452 0.66 0.381 0.445 0.420 0.463
20/16 0.861 0.284 0.35 0.465 0.58 0.404 0.505 0.448 0.515
18/20 0.876 0.409 0.53 0.569 0.77 0.489 0.486 0.514 0.512
18/18 0.977 0.419 0.48 0.587 0.71 0.529 0.547 0.558 0.569
18/16 1.094 0.427 0.44 0.604 0.65 0.566 0.617 0.598 0.631
16/20 1.105 0.564 0.61 0.698 0.81 0.619 0.582 0.633 0.609
16/18 1.206 0.577 0.56 0.719 0.75 0.673 0.646 0.689 0.671

C PANELS
16/16 1.323 0.588 0.52 0.739 0.70 0.724 0.723 0.742 0.741

D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 109


TABLE OF CONTENTS

4.3 BHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

BHF-36 Cellular Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 34.0 8' - 5" 10' - 9" 9' - 9"
20/18 34.5 8' - 7" 10' - 11" 9' - 10"
20/16 35.0 8' - 8" 11' - 0" 10' - 0"
18/20 34.7 10' - 5" 12' - 5" 11' - 11"
3 1/2 0.776 18/18 35.2 10' - 8" 13' - 3" 12' - 0"
18/16 35.7 10' - 11" 13' - 5" 12' - 2"
16/20 35.4 11' - 1" 13' - 3" 12' - 11"
16/18 35.8 11' - 4" 13' - 11" 13' - 1"
16/16 36.3 11' - 6" 14' - 1" 13' - 3"
20/20 46.1 7' - 7" 9' - 9" 8' - 10"
20/18 46.6 7' - 9" 9' - 11" 9' - 0"
20/16 47.1 7' - 10" 10' - 0" 9' - 1"
18/20 46.8 9' - 6" 11' - 3" 10' - 10"
4 1/2 1.085 18/18 47.2 9' - 9" 12' - 1" 10' - 11"
18/16 47.8 9' - 11" 12' - 2" 11' - 0"
16/20 47.4 10' - 1" 12' - 0" 12' - 1"
16/18 47.9 10' - 5" 13' - 0" 12' - 3"
16/16 48.4 10' - 7" 13' - 2" 12' - 4"
20/20 52.1 7' - 3" 9' - 5" 8' - 6"
20/18 52.6 7' - 5" 9' - 6" 8' - 7"
20/16 53.1 7' - 6" 9' - 7" 8' - 8"
5
18/20 52.8 9' - 1" 10' - 10" 10' - 4"
1.239 18/18 53.3 9' - 4" 11' - 7" 10' - 6"
1 Hour
18/16 53.8 9' - 7" 11' - 8" 10' - 7"
Fire Rating
16/20 53.5 9' - 9" 11' - 6" 11' - 9"
16/18 54.0 10' - 0" 12' - 8" 11' - 11"
16/16 54.5 10' - 3" 12' - 10" 12' - 0"
20/20 64.2 6' - 9" 8' - 9" 7' - 11"
20/18 64.7 6' - 10" 8' - 10" 8' - 0"
20/16 65.2 6' - 11" 8' - 11" 8' - 1"
6
18/20 64.9 8' - 7" 10' - 0" 9' - 8"
1.548 18/18 65.4 8' - 9" 10' - 9" 9' - 9"
2 Hour
18/16 65.9 8' - 10" 10' - 10" 9' - 10"
Fire Rating
16/20 65.6 9' - 2" 10' - 9" 11' - 1"
16/18 66.0 9' - 5" 11' - 11" 11' - 4"
16/16 66.6 9' - 7" 12' - 2" 11' - 6"
20/20 73.3 6' - 5" 8' - 4" 7' - 6"
20/18 73.8 6' - 6" 8' - 5" 7' - 7"
20/16 74.3 6' - 8" 8' - 6" 7' - 8"
6 3/4
18/20 73.9 8' - 2" 9' - 7" 9' - 2"
1.780 18/18 74.4 8' - 4" 10' - 3" 9' - 3"
3 Hour
18/16 74.9 8' - 5" 10' - 4" 9' - 4"
Fire Rating
16/20 74.6 8' - 9" 10' - 3" 10' - 8"
16/18 75.1 9' - 0" 11' - 5" 10' - 10"
16/16 75.6 9' - 3" 11' - 9" 10' - 11"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

110 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BHF-36 Cellular Composite Deck 4.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
BHF-36 Cellular Shoring Table
110 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 26.7 9' - 3" 11' - 9" 10' - 7"
20/18 27.2 9' - 4" 11' - 10" 10' - 9"
20/16 27.7 9' - 6" 11' - 11" 10' - 10"
18/20 27.3 11' - 3" 13' - 6" 12' - 11"

2W PANELS
3 1/2 0.776 18/18 27.8 11' - 6" 14' - 4" 13' - 1"
18/16 28.3 11' - 8" 14' - 5" 13' - 2"
16/20 28.0 11' - 10" 14' - 5" 13' - 4"
16/18 28.5 12' - 1" 14' - 9" 13' - 4"
16/16 29.0 12' - 3" 14' - 11" 13' - 4"
20/20 31.3 8' - 9" 11' - 2" 10' - 1"
20/18 31.7 8' - 11" 11' - 4" 10' - 3"
20/16 32.3 9' - 0" 11' - 5" 10' - 4"
4

B PANELS
18/20 31.9 10' - 9" 12' - 10" 12' - 4"
0.931 18/18 32.4 11' - 0" 13' - 9" 12' - 6"
1 Hour
18/16 32.9 11' - 3" 13' - 11" 12' - 7"
Fire Rating
16/20 32.6 11' - 5" 13' - 9" 13' - 3"
16/18 33.1 11' - 8" 14' - 3" 13' - 4"
16/16 33.6 11' - 10" 14' - 5" 13' - 4"
20/20 35.9 8' - 4" 10' - 8" 9' - 8"
20/18 36.3 8' - 6" 10' - 10" 9' - 10"

N PANELS
20/16 36.8 8' - 7" 10' - 11" 9' - 11"
18/20 36.5 10' - 4" 12' - 3" 11' - 10"
4 1/2 1.085 18/18 37.0 10' - 7" 13' - 2" 11' - 11"
18/16 37.5 10' - 10" 13' - 4" 12' - 1"
16/20 37.2 11' - 0" 13' - 2" 12' - 10"
16/18 37.7 11' - 3" 13' - 10" 13' - 0"
16/16 38.2 11' - 6" 14' - 0" 13' - 2"
20/20 38.1 8' - 2" 10' - 6" 9' - 6"

C PANELS
20/18 38.6 8' - 4" 10' - 7" 9' - 7"
20/16 39.1 8' - 5" 10' - 8" 9' - 8"
4 3/4
18/20 38.8 10' - 2" 12' - 1" 11' - 7"
1.162 18/18 39.3 10' - 5" 12' - 11" 11' - 8"
2 Hour
18/16 39.8 10' - 7" 13' - 0" 11' - 10"
Fire Rating
16/20 39.5 10' - 10" 12' - 10" 12' - 8"
16/18 39.9 11' - 1" 13' - 8" 12' - 10"
16/16 40.5 11' - 4" 13' - 10" 13' - 0"
20/20 46.7 7' - 7" 9' - 10" 8' - 11"
D PANEL

20/18 47.2 7' - 9" 9' - 11" 9' - 0"


20/16 47.7 7' - 10" 10' - 0" 9' - 1"
5 11/16
18/20 47.4 9' - 6" 11' - 3" 10' - 10"
1.452 18/18 47.9 9' - 9" 12' - 1" 10' - 11"
3 Hour
18/16 48.4 10' - 0" 12' - 2" 11' - 1"
Fire Rating
16/20 48.1 10' - 2" 12' - 1" 12' - 1"
16/18 48.5 10' - 5" 13' - 0" 12' - 3"
ACUSTADEK®

16/16 49.1 10' - 8" 13' - 2" 12' - 5"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 111


TABLE OF CONTENTS

4.4 BH-36 Composite Deck


3 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 0.776yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 6' - 7" 6' - 11" 7' - 10" 18 8' - 11" 10' - 7" 11' - 2"
20 7' - 10" 8' - 6" 9' - 4" 16 9' - 8" 11' - 11" 11' - 9"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 523 428 356 300 255 219 190 165 145 127 113 100 89 79 71
LRFD, ϕW 837 685 569 480 408 351 303 264 232 204 180 160 142 127 113
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2634 2570 2517 2489 2449 2414 2384 2358 2334 2324 2305 2287 2271 2256 2243
PAF Base Steel ≥ .25" 2318 2283 2254 2246 2223 2204 2187 2172 2159 2158 2147 2137 2127 2119 2111
PAF Base Steel ≥ 0.125" 2294 2261 2234 2227 2206 2188 2172 2158 2145 2145 2135 2125 2116 2108 2101
#12 Screw Base Steel ≥ .0385" 2271 2241 2215 2210 2190 2173 2158 2144 2133 2133 2123 2114 2106 2098 2092
Concrete + Deck = 32.1 psf Icr = 17.4 in4/ft Mno/Ω= 21.5 kip-in/ft Vn/Ω = 1.90 kip/ft
(Icr+Iu)/2 = 26.57 in4/ft Iu = 35.7 in4/ft ϕMno= 32.8 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 615 504 420 354 302 260 225 197 173 153 132 114 100 87 77
LRFD, ϕW 984 806 671 566 483 416 361 315 277 244 217 193 172 154 139
L/360 - - - - - - - - - - 132 114 100 87 77
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2783 2705 2640 2609 2560 2518 2481 2448 2419 2410 2385 2364 2344 2326 2309
PAF Base Steel ≥ .25" 2398 2355 2319 2313 2285 2261 2240 2222 2206 2207 2193 2180 2169 2158 2149
PAF Base Steel ≥ 0.125" 2369 2328 2295 2290 2264 2242 2222 2205 2189 2192 2178 2166 2156 2146 2136
#12 Screw Base Steel ≥ .0385" 2344 2306 2274 2271 2247 2225 2207 2190 2176 2179 2166 2155 2144 2135 2126
Concrete + Deck = 32.5 psf Icr = 19.8 in4/ft Mno/Ω= 25.1 kip-in/ft Vn/Ω = 1.90 kip/ft
(Icr+Iu)/2 = 28.33 in4/ft Iu = 36.9 in4/ft ϕMno= 38.4 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 760 638 532 450 385 332 286 238 201 171 146 126 110 96 85
LRFD, ϕW 1141 1021 852 720 615 531 462 404 356 316 281 251 225 203 183
L/360 - - - - - - 286 238 201 171 146 126 110 96 85
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3091 2984 2895 2861 2794 2735 2684 2639 2598 2591 2558 2527 2499 2474 2450
PAF Base Steel ≥ .25" 2563 2504 2455 2456 2417 2384 2354 2328 2305 2314 2294 2276 2259 2244 2231
PAF Base Steel ≥ 0.125" 2525 2469 2423 2426 2390 2358 2330 2306 2284 2293 2275 2257 2242 2228 2215
#12 Screw Base Steel ≥ .0385" 2498 2445 2401 2406 2370 2340 2314 2290 2269 2279 2261 2245 2230 2216 2203
Concrete + Deck = 33.2 psf Icr = 23.6 in4/ft Mno/Ω= 31.5 kip-in/ft Vn/Ω = 1.90 kip/ft
(Icr+Iu)/2 = 31.31 in /ft
4
Iu = 39.0 in4/ft ϕMno= 48.1 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 760 691 634 542 464 377 311 259 218 186 159 137 120 105 92
LRFD, ϕW 1141 1037 951 868 742 641 559 490 433 385 343 307 276 250 226
L/360 - - - - 464 377 311 259 218 186 159 137 120 105 92
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3419 3281 3166 3135 3047 2971 2904 2845 2793 2791 2747 2707 2670 2637 2606
PAF Base Steel ≥ .25" 2740 2664 2600 2613 2562 2518 2480 2446 2416 2434 2407 2383 2361 2342 2323
PAF Base Steel ≥ 0.125" 2666 2597 2539 2556 2509 2469 2434 2402 2375 2395 2370 2348 2328 2309 2293
#12 Screw Base Steel ≥ .0385" 2679 2609 2551 2568 2522 2481 2446 2415 2387 2407 2383 2360 2340 2322 2305
Concrete + Deck = 33.8 psf Icr = 27.0 in4/ft Mno/Ω= 37.6 kip-in/ft Vn/Ω = 1.90 kip/ft
(Icr+Iu)/2 = 34.04 in4/ft Iu = 41.0 in4/ft ϕMno= 57.6 kip-in/ft ϕ Vn = 2.85 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 3200 4550 5540 7340 10040
12 in o.c. 3200 4550 5540 7340 10040
18 in o.c. 3200 4550 5540 7340 8790

112 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BH-36 Composite Deck 4.4

GENERAL INFORMATION
4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 0.931yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 6' - 3" 6' - 8" 7' - 5" 18 8' - 6" 10' - 1" 10' - 8"
20 7' - 6" 8' - 2" 8' - 10" 16 9' - 2" 11' - 4" 11' - 4"

3W PANELS
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 663 543 451 380 324 279 241 211 185 163 144 128 114 102 91
LRFD, ϕW 1060 868 722 609 518 446 386 337 295 261 231 205 183 163 146
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3124 3061 3008 2979 2939 2905 2875 2848 2825 2815 2795 2777 2761 2747 2733
PAF Base Steel ≥ .25" 2809 2774 2745 2736 2714 2695 2678 2663 2649 2649 2637 2627 2618 2609 2602
PAF Base Steel ≥ 0.125" 2784 2752 2724 2717 2696 2678 2662 2648 2636 2636 2625 2615 2607 2599 2591

2W PANELS
#12 Screw Base Steel ≥ .0385" 2762 2731 2705 2700 2680 2663 2648 2635 2623 2624 2614 2605 2596 2589 2582
Concrete + Deck = 38.2 psf Icr = 25.4 in4/ft Mno/Ω= 27.1 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 39.42 in4/ft Iu = 53.4 in4/ft ϕMno= 41.5 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 780 640 533 450 384 331 287 251 221 195 173 155 138 124 112
LRFD, ϕW 1248 1024 853 720 614 529 459 402 353 312 277 247 221 198 179
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 3273 3195 3130 3099 3050 3008 2971 2939 2910 2900 2876 2854 2834 2816 2799
PAF Base Steel ≥ .25" 2888 2845 2810 2803 2776 2752 2731 2712 2696 2698 2684 2671 2659 2649 2639
PAF Base Steel ≥ 0.125" 2859 2819 2785 2781 2755 2732 2713 2695 2680 2682 2669 2657 2646 2636 2627
#12 Screw Base Steel ≥ .0385" 2834 2796 2765 2762 2737 2716 2697 2681 2666 2669 2657 2645 2635 2625 2617
Concrete + Deck = 38.5 psf Icr = 28.8 in4/ft Mno/Ω= 31.7 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 42 in4/ft Iu = 55.2 in4/ft ϕMno= 48.5 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 906 814 680 575 491 424 369 324 286 253 217 187 163 143 126
LRFD, ϕW 1358 1235 1087 919 786 679 591 518 457 405 361 323 290 262 237
L/360 - - - - - - - - - 253 217 187 163 143 126
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3581 3474 3385 3352 3284 3226 3174 3129 3089 3082 3048 3017 2990 2964 2941
PAF Base Steel ≥ .25" 3053 2995 2945 2946 2907 2874 2845 2819 2796 2804 2784 2766 2750 2735 2721
PAF Base Steel ≥ 0.125" 3015 2960 2913 2916 2880 2848 2821 2796 2774 2784 2765 2748 2732 2718 2705
#12 Screw Base Steel ≥ .0385" 2988 2935 2891 2896 2861 2831 2804 2780 2760 2770 2752 2735 2720 2706 2694
Concrete + Deck = 39.8 psf Icr = 34.6 in4/ft Mno/Ω= 40.0 kip-in/ft Vn/Ω = 2.26 kip/ft

C PANELS
(Icr+Iu)/2 = 46.4 in /ft
4
Iu = 58.2 in4/ft ϕMno= 61.3 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 906 823 755 695 595 514 448 384 323 275 236 204 177 155 136
LRFD, ϕW 1358 1235 1132 1045 952 823 717 630 557 495 442 396 357 323 292
L/360 - - - - - - - 384 323 275 236 204 177 155 136
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3910 3772 3657 3626 3538 3461 3395 3336 3283 3282 3237 3197 3161 3127 3097
D PANEL

PAF Base Steel ≥ .25" 3230 3154 3091 3103 3053 3009 2970 2936 2906 2924 2898 2874 2852 2832 2814
PAF Base Steel ≥ 0.125" 3157 3087 3029 3046 3000 2959 2924 2893 2865 2885 2861 2839 2818 2800 2783
#12 Screw Base Steel ≥ .0385" 3169 3100 3042 3059 3012 2972 2936 2905 2877 2898 2873 2851 2830 2812 2795
Concrete + Deck = 39.2 psf Icr = 39.8 in4/ft Mno/Ω= 48.0 kip-in/ft Vn/Ω = 2.26 kip/ft
(Icr+Iu)/2 = 50.4 in4/ft Iu = 61.1 in4/ft ϕMno= 73.5 kip-in/ft ϕ Vn = 3.40 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 3700 5050 6040 7840 10540
12 in o.c. 3700 5050 6040 7840 10540
18 in o.c. 3700 5050 6040 7840 8790

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 113


TABLE OF CONTENTS

4.4 BH-36 Composite Deck


4 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.085yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 6' - 0" 6' - 6" 7' - 1" 18 8' - 2" 9' - 8" 10' - 2"
20 7' - 2" 7' - 10" 8' - 5" 16 8' - 9" 10' - 10" 10' - 11"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 809 663 552 465 396 341 296 258 227 200 177 158 141 126 113
LRFD, ϕW 1294 1060 883 744 634 546 473 413 363 320 284 252 225 202 181
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3615 3551 3498 3469 3430 3395 3365 3339 3315 3305 3286 3268 3252 3237 3223
PAF Base Steel ≥ .25" 3299 3264 3235 3227 3204 3185 3168 3153 3140 3139 3128 3118 3108 3100 3092
PAF Base Steel ≥ 0.125" 3275 3242 3215 3208 3187 3169 3153 3139 3126 3126 3115 3106 3097 3089 3082
#12 Screw Base Steel ≥ .0385" 3252 3221 3196 3191 3171 3154 3139 3125 3114 3114 3104 3095 3087 3079 3072
Concrete + Deck = 44.2 psf Icr = 35.2 in4/ft Mno/Ω= 33.0 kip-in/ft Vn/Ω = 2.65 kip/ft
(Icr+Iu)/2 = 55.87 in4/ft Iu = 76.6 in4/ft ϕMno= 50.5 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 954 783 652 551 470 405 352 308 271 240 213 190 171 153 138
LRFD, ϕW 1527 1252 1044 881 753 649 564 493 434 384 342 305 273 245 221
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3763 3686 3621 3590 3541 3499 3462 3429 3400 3390 3366 3344 3325 3306 3290
PAF Base Steel ≥ .25" 3379 3336 3300 3294 3266 3242 3221 3203 3186 3188 3174 3161 3150 3139 3130
PAF Base Steel ≥ 0.125" 3349 3309 3276 3271 3245 3223 3203 3186 3170 3173 3159 3147 3136 3126 3117
#12 Screw Base Steel ≥ .0385" 3325 3287 3255 3252 3228 3206 3188 3171 3156 3160 3147 3136 3125 3116 3107
Concrete + Deck = 44.6 psf Icr = 40.0 in4/ft Mno/Ω= 38.7 kip-in/ft Vn/Ω = 2.65 kip/ft
(Icr+Iu)/2 = 59.46 in4/ft Iu = 78.9 in4/ft ϕMno= 59.3 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1060 963 835 707 605 522 455 399 352 313 279 250 225 202 178
LRFD, ϕW 1590 1445 1325 1131 968 836 728 639 564 501 446 400 360 324 293
L/360 - - - - - - - - - - - - - 202 178
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 4071 3964 3875 3842 3775 3716 3665 3620 3579 3572 3538 3508 3480 3455 3431
PAF Base Steel ≥ .25" 3544 3485 3436 3436 3398 3364 3335 3309 3286 3295 3275 3257 3240 3225 3211
PAF Base Steel ≥ 0.125" 3505 3450 3404 3407 3370 3339 3311 3287 3265 3274 3255 3238 3223 3208 3195
#12 Screw Base Steel ≥ .0385" 3479 3426 3382 3386 3351 3321 3294 3271 3250 3260 3242 3226 3211 3197 3184
Concrete + Deck = 45.2 psf Icr = 48.2 in4/ft Mno/Ω= 49.1 kip-in/ft Vn/Ω = 2.65 kip/ft
(Icr+Iu)/2 = 65.67 in /ft
4
Iu = 83.1 in4/ft ϕMno= 75.1 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1060 963 883 815 734 635 554 487 430 383 334 288 251 219 193
LRFD, ϕW 1590 1445 1325 1223 1136 1016 886 779 689 613 547 491 443 400 363
L/360 - - - - - - - - - - 334 288 251 219 193
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4400 4262 4147 4116 4028 3952 3885 3826 3774 3772 3728 3688 3651 3618 3587
PAF Base Steel ≥ .25" 3721 3645 3581 3594 3543 3499 3461 3427 3397 3415 3388 3364 3342 3322 3304
PAF Base Steel ≥ 0.125" 3647 3578 3520 3537 3490 3450 3414 3383 3356 3376 3351 3329 3309 3290 3273
#12 Screw Base Steel ≥ .0385" 3660 3590 3532 3549 3503 3462 3427 3396 3368 3388 3363 3341 3321 3302 3285
Concrete + Deck = 45.9 psf Icr = 55.6 in4/ft Mno/Ω= 59.1 kip-in/ft Vn/Ω = 2.65 kip/ft
(Icr+Iu)/2 = 71.36 in4/ft Iu = 87.1 in4/ft ϕMno= 90.4 kip-in/ft ϕ Vn = 3.97 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 4190 5540 6530 8330 11030
12 in o.c. 4190 5540 6530 8330 11030
18 in o.c. 4190 5540 6530 8330 8790

114 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BH-36 Composite Deck 4.4

GENERAL INFORMATION
5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.239yd3/100ft2
1 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 5' - 9" 6' - 3" 6' - 10" 18 7' - 10" 9' - 3" 9' - 9"
20 6' - 10" 7' - 7" 8' - 1" 16 8' - 5" 10' - 5" 10' - 6"

3W PANELS
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 960 787 655 553 471 406 352 308 270 239 212 189 168 151 136
LRFD, ϕW 1536 1259 1048 884 754 649 563 492 432 382 339 302 270 241 217
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 4105 4042 3988 3960 3920 3886 3856 3829 3805 3796 3776 3758 3742 3727 3714
PAF Base Steel ≥ .25" 3790 3755 3725 3717 3695 3675 3658 3643 3630 3629 3618 3608 3599 3590 3582
PAF Base Steel ≥ 0.125" 3765 3732 3705 3698 3677 3659 3643 3629 3616 3617 3606 3596 3588 3580 3572

2W PANELS
#12 Screw Base Steel ≥ .0385" 3743 3712 3686 3681 3661 3644 3629 3616 3604 3605 3595 3586 3577 3570 3563
Concrete + Deck = 50.3 psf Icr = 46.8 in4/ft Mno/Ω= 39.1 kip-in/ft Vn/Ω = 3.06 kip/ft
(Icr+Iu)/2 = 76.31 in4/ft Iu = 105.8 in4/ft ϕMno= 59.9 kip-in/ft ϕ Vn = 4.59 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1134 931 776 656 560 483 420 368 324 287 255 228 204 184 166
LRFD, ϕW 1815 1489 1242 1049 896 773 672 588 518 459 408 365 327 294 265
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 4254 4176 4111 4080 4031 3989 3952 3920 3891 3881 3857 3835 3815 3797 3780
PAF Base Steel ≥ .25" 3869 3826 3791 3784 3757 3733 3712 3693 3677 3678 3664 3652 3640 3630 3620
PAF Base Steel ≥ 0.125" 3840 3800 3766 3762 3736 3713 3693 3676 3661 3663 3650 3638 3627 3617 3608
#12 Screw Base Steel ≥ .0385" 3815 3777 3746 3743 3718 3697 3678 3662 3647 3650 3637 3626 3616 3606 3597
Concrete + Deck = 50.6 psf Icr = 53.4 in4/ft Mno/Ω= 46.0 kip-in/ft Vn/Ω = 3.06 kip/ft
(Icr+Iu)/2 = 81.12 in4/ft Iu = 108.9 in4/ft ϕMno= 70.3 kip-in/ft ϕ Vn = 4.59 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 1223 1112 998 844 723 625 544 478 422 375 334 300 270 244 221
LRFD, ϕW 1835 1668 1529 1351 1156 999 871 764 675 600 535 480 432 390 353
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 4562 4455 4366 4333 4265 4206 4155 4110 4070 4063 4029 3998 3970 3945 3922
PAF Base Steel ≥ .25" 4034 3975 3926 3927 3888 3855 3826 3800 3777 3785 3765 3747 3731 3716 3702
PAF Base Steel ≥ 0.125" 3996 3940 3894 3897 3861 3829 3801 3777 3755 3765 3746 3729 3713 3699 3686
#12 Screw Base Steel ≥ .0385" 3969 3916 3872 3877 3842 3811 3785 3761 3741 3751 3732 3716 3701 3687 3675
Concrete + Deck = 51.3 psf Icr = 64.6 in4/ft Mno/Ω= 58.5 kip-in/ft Vn/Ω = 3.06 kip/ft

C PANELS
(Icr+Iu)/2 = 89.54 in /ft
4
Iu = 114.5 in4/ft ϕMno= 89.5 kip-in/ft ϕ Vn = 4.59 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1223 1112 1019 941 874 761 664 584 517 460 411 369 333 299 263
LRFD, ϕW 1835 1668 1529 1411 1311 1218 1063 934 827 735 658 591 533 482 438
L/360 - - - - - - - - - - - - - 299 263
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4890 4753 4638 4607 4519 4442 4376 4317 4264 4263 4218 4178 4142 4108 4078
D PANEL

PAF Base Steel ≥ .25" 4211 4135 4072 4084 4033 3989 3951 3917 3887 3905 3879 3855 3833 3813 3795
PAF Base Steel ≥ 0.125" 4137 4068 4010 4027 3981 3940 3905 3874 3846 3866 3842 3819 3799 3781 3764
#12 Screw Base Steel ≥ .0385" 4150 4081 4023 4040 3993 3953 3917 3886 3858 3879 3854 3832 3811 3793 3776
Concrete + Deck = 52.0 psf Icr = 74.7 in4/ft Mno/Ω= 70.6 kip-in/ft Vn/Ω = 3.06 kip/ft
(Icr+Iu)/2 = 97.25 in4/ft Iu = 119.8 in4/ft ϕMno= 108.0 kip-in/ft ϕ Vn = 4.59 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. n/a 6030 7020 8820 11520
12 in o.c. n/a 6030 7020 8820 11520
18 in o.c. n/a 6030 7020 8790 8790

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 115


TABLE OF CONTENTS

4.4 BH-36 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.548yd3/100ft2
2 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 5' - 4" 5' - 11" 6' - 4" 18 7' - 4" 8' - 8" 9' - 0"
20 6' - 4" 7' - 1" 7' - 6" 16 7' - 11" 9' - 8" 9' - 10"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1273 1044 869 734 626 540 469 410 360 319 283 252 226 203 182
LRFD, ϕW 2036 1670 1391 1174 1002 863 750 656 577 510 453 404 361 324 292
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 5086 5022 4969 4941 4901 4867 4836 4810 4786 4776 4757 4739 4723 4708 4695
PAF Base Steel ≥ .25" 4771 4736 4706 4698 4676 4656 4639 4624 4611 4610 4599 4589 4580 4571 4563
PAF Base Steel ≥ 0.125" 4746 4713 4686 4679 4658 4640 4624 4610 4597 4597 4587 4577 4568 4560 4553
#12 Screw Base Steel ≥ .0385" 4724 4693 4667 4662 4642 4625 4610 4597 4585 4586 4576 4566 4558 4551 4544
Concrete + Deck = 62.4 psf Icr = 75.7 in4/ft Mno/Ω= 51.7 kip-in/ft Vn/Ω = 3.94 kip/ft
(Icr+Iu)/2 = 130.7 in4/ft Iu = 185.8 in4/ft ϕMno= 79.2 kip-in/ft ϕ Vn = 5.92 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1507 1237 1032 872 746 644 560 491 433 383 341 305 274 247 223
LRFD, ϕW 2366 1979 1651 1396 1193 1030 896 785 692 613 546 489 438 395 356
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 5235 5157 5092 5061 5012 4970 4933 4900 4871 4862 4838 4816 4796 4778 4761
PAF Base Steel ≥ .25" 4850 4807 4771 4765 4737 4714 4693 4674 4658 4659 4645 4633 4621 4610 4601
PAF Base Steel ≥ 0.125" 4821 4781 4747 4743 4717 4694 4674 4657 4641 4644 4631 4619 4608 4598 4589
#12 Screw Base Steel ≥ .0385" 4796 4758 4726 4724 4699 4678 4659 4642 4628 4631 4618 4607 4597 4587 4578
Concrete + Deck = 62.7 psf Icr = 86.6 in4/ft Mno/Ω= 60.9 kip-in/ft Vn/Ω = 3.94 kip/ft
(Icr+Iu)/2 = 138.6 in4/ft Iu = 190.6 in4/ft ϕMno= 93.2 kip-in/ft ϕ Vn = 5.92 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1577 1434 1315 1130 968 837 730 641 567 504 450 404 364 329 298
LRFD, ϕW 2366 2151 1972 1808 1548 1339 1167 1025 907 806 720 646 582 526 477
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5543 5436 5347 5314 5246 5187 5136 5091 5051 5043 5010 4979 4951 4926 4903
PAF Base Steel ≥ .25" 5015 4956 4907 4908 4869 4836 4806 4781 4758 4766 4746 4728 4711 4696 4683
PAF Base Steel ≥ 0.125" 4977 4921 4875 4878 4842 4810 4782 4758 4736 4746 4727 4710 4694 4680 4667
#12 Screw Base Steel ≥ .0385" 4950 4897 4853 4858 4823 4792 4766 4742 4721 4732 4713 4697 4682 4668 4656
Concrete + Deck = 63.4 psf Icr = 105.7 in4/ft Mno/Ω= 78.0 kip-in/ft Vn/Ω = 3.94 kip/ft
(Icr+Iu)/2 = 152.7 in /ft
4
Iu = 199.7 in4/ft ϕMno= 119.4 kip-in/ft ϕ Vn = 5.92 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1577 1434 1315 1213 1127 1023 894 786 696 620 555 499 450 408 371
LRFD, ϕW 2366 2151 1972 1820 1690 1577 1430 1258 1114 992 888 798 720 652 593
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 5871 5734 5619 5587 5499 5423 5356 5298 5245 5244 5199 5159 5122 5089 5058
PAF Base Steel ≥ .25" 5192 5116 5053 5065 5014 4970 4932 4898 4868 4886 4859 4835 4814 4794 4775
PAF Base Steel ≥ 0.125" 5118 5049 4991 5008 4962 4921 4886 4855 4827 4847 4823 4800 4780 4762 4745
#12 Screw Base Steel ≥ .0385" 5131 5061 5004 5021 4974 4933 4898 4867 4839 4859 4835 4812 4792 4774 4757
Concrete + Deck = 64.0 psf Icr = 122.9 in4/ft Mno/Ω= 94.5 kip-in/ft Vn/Ω = 3.94 kip/ft
(Icr+Iu)/2 = 165.6 in4/ft Iu = 208.3 in4/ft ϕMno= 144.7 kip-in/ft ϕ Vn = 5.92 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. n/a 7020 8010 9810 12510
12 in o.c. n/a 7020 8010 9810 12510
18 in o.c. n/a 7020 8010 8790 8790

116 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BH-36 Composite Deck 4.4

GENERAL INFORMATION
6 3⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.780yd3/100ft2
3 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 5' - 1" 5' - 8" 6' - 0" 18 7' - 0" 8' - 3" 8' - 7"
20 6' - 1" 6' - 10" 7' - 1" 16 7' - 7" 9' - 2" 9' - 5"

3W PANELS
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1513 1241 1034 873 746 643 558 488 430 380 338 302 270 243 218
LRFD, ϕW 2420 1986 1655 1397 1193 1028 893 781 688 609 541 483 432 388 349
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 5822 5758 5705 5676 5637 5602 5572 5546 5522 5512 5492 5475 5459 5444 5430
PAF Base Steel ≥ .25" 5506 5471 5442 5434 5411 5392 5375 5360 5347 5346 5335 5324 5315 5307 5299
PAF Base Steel ≥ 0.125" 5482 5449 5422 5415 5394 5376 5360 5346 5333 5333 5322 5313 5304 5296 5289

2W PANELS
#12 Screw Base Steel ≥ .0385" 5459 5428 5403 5397 5378 5361 5345 5332 5320 5321 5311 5302 5294 5286 5279
Concrete + Deck = 71.4 psf Icr = 102.5 in4/ft Mno/Ω= 61.4 kip-in/ft Vn/Ω = 4.67 kip/ft
(Icr+Iu)/2 = 184.9 in4/ft Iu = 267.4 in4/ft ϕMno= 94.0 kip-in/ft ϕ Vn = 7.00 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1794 1473 1229 1039 889 767 668 585 516 458 408 365 328 295 267
LRFD, ϕW 2801 2357 1967 1663 1422 1228 1068 937 826 733 653 584 525 473 427
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 5970 5893 5828 5797 5748 5706 5669 5636 5607 5597 5573 5551 5532 5513 5497
PAF Base Steel ≥ .25" 5586 5543 5507 5501 5473 5449 5428 5410 5393 5395 5381 5368 5357 5346 5336
PAF Base Steel ≥ 0.125" 5556 5516 5483 5478 5452 5430 5410 5393 5377 5380 5366 5354 5343 5333 5324
#12 Screw Base Steel ≥ .0385" 5532 5494 5462 5459 5435 5413 5395 5378 5363 5367 5354 5343 5332 5323 5314
Concrete + Deck = 71.8 psf Icr = 117.5 in4/ft Mno/Ω= 72.4 kip-in/ft Vn/Ω = 4.67 kip/ft
(Icr+Iu)/2 = 195.7 in4/ft Iu = 273.9 in4/ft ϕMno= 110.8 kip-in/ft ϕ Vn = 7.00 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 1867 1697 1556 1350 1157 1001 873 767 678 603 539 484 436 394 358
LRFD, ϕW 2801 2546 2334 2154 1851 1601 1397 1227 1085 965 863 774 698 631 572
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 6278 6171 6082 6049 5982 5923 5872 5826 5786 5779 5745 5715 5687 5661 5638
PAF Base Steel ≥ .25" 5751 5692 5643 5643 5605 5571 5542 5516 5493 5501 5482 5464 5447 5432 5418
PAF Base Steel ≥ 0.125" 5712 5657 5611 5614 5577 5546 5518 5494 5472 5481 5462 5445 5430 5415 5402
#12 Screw Base Steel ≥ .0385" 5686 5633 5589 5593 5558 5528 5501 5478 5457 5467 5449 5433 5418 5404 5391
Concrete + Deck = 72.4 psf Icr = 144.0 in4/ft Mno/Ω= 93.1 kip-in/ft Vn/Ω = 4.67 kip/ft

C PANELS
(Icr+Iu)/2 = 215.1 in /ft
4
Iu = 286.1 in4/ft ϕMno= 142.4 kip-in/ft ϕ Vn = 7.00 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1867 1697 1556 1436 1334 1227 1071 943 835 744 666 599 541 490 446
LRFD, ϕW 2801 2546 2334 2154 2000 1867 1714 1508 1336 1190 1066 958 865 784 713
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 6607 6469 6354 6323 6235 6159 6092 6033 5981 5979 5935 5895 5858 5825 5794
D PANEL

PAF Base Steel ≥ .25" 5928 5852 5788 5801 5750 5706 5668 5634 5603 5622 5595 5571 5549 5529 5511
PAF Base Steel ≥ 0.125" 5854 5785 5727 5744 5697 5657 5621 5590 5562 5583 5558 5536 5516 5497 5480
#12 Screw Base Steel ≥ .0385" 5866 5797 5739 5756 5710 5669 5634 5602 5575 5595 5570 5548 5528 5509 5492
Concrete + Deck = 73.1 psf Icr = 168.1 in4/ft Mno/Ω= 113.1 kip-in/ft Vn/Ω = 4.67 kip/ft
(Icr+Iu)/2 = 232.9 in4/ft Iu = 297.7 in4/ft ϕMno= 173.0 kip-in/ft ϕ Vn = 7.00 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. n/a 7760 8750 10550 13250
12 in o.c. n/a 7760 8750 10550 13180
18 in o.c. n/a 7760 8750 8790 8790

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 117


TABLE OF CONTENTS

4.4 BH-36 Composite Deck


3 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 0.776yd3/100ft2

Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 7' - 1" 7' - 2" 8' - 6" 18 9' - 9" 11' - 4" 12' - 0"
20 8' - 7" 9' - 0" 10' - 2" 16 10' - 6" 12' - 11" 12' - 7"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 497 408 340 287 245 211 183 156 131 112 96 83 72 63 55
LRFD, ϕW 796 653 544 459 391 337 293 256 225 199 177 157 141 126 114
L/360 - - - - - - - 156 131 112 96 83 72 63 55
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 1978 1915 1862 1833 1793 1759 1729 1702 1679 1669 1649 1631 1615 1601 1587
PAF Base Steel ≥ .25" 1663 1628 1599 1590 1568 1549 1532 1517 1503 1503 1491 1481 1472 1463 1456
PAF Base Steel ≥ 0.125" 1638 1606 1578 1571 1550 1532 1516 1502 1490 1490 1479 1469 1461 1453 1445
#12 Screw Base Steel ≥ .0385" 1616 1585 1559 1554 1534 1517 1502 1489 1477 1478 1468 1459 1450 1443 1436
Concrete + Deck = 24.8 psf Icr = 23.1 in4/ft Mno/Ω= 20.2 kip-in/ft Vn/Ω = 1.43 kip/ft
(Icr+Iu)/2 = 30.97 in4/ft Iu = 38.8 in4/ft ϕMno= 31.0 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 570 477 398 336 287 243 200 167 141 120 103 89 77 67 59
LRFD, ϕW 930 763 637 538 460 397 345 302 266 236 210 188 168 151 137
L/360 - - - - - 243 200 167 141 120 103 89 77 67 59
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2129 2051 1986 1955 1906 1864 1827 1795 1766 1756 1732 1710 1690 1672 1655
PAF Base Steel ≥ .25" 1744 1701 1666 1659 1632 1608 1587 1568 1552 1554 1540 1527 1515 1505 1495
PAF Base Steel ≥ 0.125" 1715 1675 1641 1637 1611 1588 1569 1551 1536 1538 1525 1513 1502 1492 1483
#12 Screw Base Steel ≥ .0385" 1690 1652 1621 1618 1593 1572 1553 1537 1522 1525 1513 1501 1491 1481 1473
Concrete + Deck = 25.1 psf Icr = 26.0 in4/ft Mno/Ω= 23.5 kip-in/ft Vn/Ω = 1.43 kip/ft
(Icr+Iu)/2 = 33.23 in4/ft Iu = 40.5 in4/ft ϕMno= 36.0 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 570 518 475 416 333 271 223 186 157 133 114 99 86 75 66
LRFD, ϕW 1141 957 799 676 579 500 436 383 338 300 268 240 216 195 177
L/360 - - - 416 333 271 223 186 157 133 114 99 86 75 66
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2441 2334 2245 2212 2144 2086 2034 1989 1949 1942 1908 1877 1849 1824 1801
PAF Base Steel ≥ .25" 1913 1854 1805 1806 1767 1734 1705 1679 1656 1664 1644 1626 1610 1595 1581
PAF Base Steel ≥ 0.125" 1875 1819 1773 1776 1740 1708 1681 1656 1634 1644 1625 1608 1592 1578 1565
#12 Screw Base Steel ≥ .0385" 1848 1795 1751 1756 1721 1690 1664 1640 1620 1630 1612 1595 1580 1566 1554
Concrete + Deck = 25.8 psf Icr = 30.6 in4/ft Mno/Ω= 29.3 kip-in/ft Vn/Ω = 1.43 kip/ft
(Icr+Iu)/2 = 36.95 in4/ft Iu = 43.3 in4/ft ϕMno= 44.8 kip-in/ft ϕ Vn = 2.85 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 570 518 475 439 363 295 243 203 171 145 125 108 94 82 72
LRFD, ϕW 1141 1037 951 808 692 599 523 459 406 361 323 290 261 236 215
L/360 - - - - 363 295 243 203 171 145 125 108 94 82 72
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2774 2636 2521 2490 2402 2325 2259 2200 2147 2146 2101 2061 2025 1991 1961
PAF Base Steel ≥ .25" 2094 2018 1955 1967 1916 1873 1834 1800 1770 1788 1762 1738 1716 1696 1678
PAF Base Steel ≥ 0.125" 2020 1951 1893 1910 1864 1823 1788 1757 1729 1749 1725 1703 1682 1664 1647
#12 Screw Base Steel ≥ .0385" 2029 1960 1902 1919 1872 1832 1796 1765 1737 1758 1733 1711 1690 1672 1655
Concrete + Deck = 26.5 psf Icr = 34.6 in4/ft Mno/Ω= 34.8 kip-in/ft Vn/Ω = 1.43 kip/ft
(Icr+Iu)/2 = 40.33 in4/ft Iu = 46.0 in4/ft ϕMno= 53.2 kip-in/ft ϕ Vn = 2.85 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 2720 4070 5060 6860 9560
12 in o.c. 2720 4070 5060 6860 9560
18 in o.c. 2720 4070 5060 6860 8790

118 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BH-36 Composite Deck 4.4

GENERAL INFORMATION
4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 0.931yd3/100ft2
1 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 6' - 10" 7' - 0" 8' - 1" 18 9' - 3" 10' - 11" 11' - 7"
20 8' - 2" 8' - 8" 9' - 8" 16 10' - 0" 12' - 4" 12' - 1"

3W PANELS
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 633 519 433 365 312 269 234 205 180 159 142 122 106 93 82
LRFD, ϕW 1013 831 692 585 499 430 374 327 288 255 227 202 181 163 147
L/360 - - - - - - - - - - 142 122 106 93 82
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2303 2239 2186 2157 2117 2083 2053 2026 2003 1993 1973 1955 1939 1925 1911
PAF Base Steel ≥ .25" 1987 1952 1923 1914 1892 1873 1856 1841 1827 1827 1815 1805 1796 1787 1780
PAF Base Steel ≥ 0.125" 1962 1930 1902 1896 1874 1856 1840 1826 1814 1814 1803 1793 1785 1777 1769

2W PANELS
#12 Screw Base Steel ≥ .0385" 1940 1909 1883 1878 1858 1841 1826 1813 1801 1802 1792 1783 1774 1767 1760
Concrete + Deck = 29.4 psf Icr = 33.8 in4/ft Mno/Ω= 25.7 kip-in/ft Vn/Ω = 1.70 kip/ft
(Icr+Iu)/2 = 45.86 in4/ft Iu = 57.9 in4/ft ϕMno= 39.3 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 679 608 508 429 367 317 276 242 208 177 152 131 114 100 88
LRFD, ϕW 1186 974 812 687 587 507 441 387 341 303 270 241 217 195 176
L/360 - - - - - - - - 208 177 152 131 114 100 88
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 2453 2375 2310 2279 2231 2188 2151 2119 2090 2080 2056 2034 2014 1996 1979
PAF Base Steel ≥ .25" 2068 2025 1990 1983 1956 1932 1911 1892 1876 1878 1864 1851 1839 1829 1819
PAF Base Steel ≥ 0.125" 2039 1999 1965 1961 1935 1912 1893 1875 1860 1862 1849 1837 1826 1816 1807
#12 Screw Base Steel ≥ .0385" 2014 1976 1945 1942 1917 1896 1877 1861 1846 1849 1837 1825 1815 1805 1797
Concrete + Deck = 29.7 psf Icr = 38.1 in4/ft Mno/Ω= 29.9 kip-in/ft Vn/Ω = 1.70 kip/ft
(Icr+Iu)/2 = 49.16 in4/ft Iu = 60.3 in4/ft ϕMno= 45.8 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 679 617 566 522 465 400 330 275 232 197 169 146 127 111 98
LRFD, ϕW 1358 1227 1025 868 743 643 561 492 435 387 346 310 279 252 229
L/360 - - - - - 400 330 275 232 197 169 146 127 111 98
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2765 2658 2569 2536 2468 2410 2358 2313 2273 2266 2232 2201 2174 2148 2125
PAF Base Steel ≥ .25" 2237 2179 2129 2130 2091 2058 2029 2003 1980 1988 1968 1950 1934 1919 1905
PAF Base Steel ≥ 0.125" 2199 2144 2097 2100 2064 2032 2005 1980 1958 1968 1949 1932 1916 1902 1889
#12 Screw Base Steel ≥ .0385" 2172 2119 2075 2080 2045 2015 1988 1965 1944 1954 1936 1919 1904 1890 1878
Concrete + Deck = 30.4 psf Icr = 45.0 in4/ft Mno/Ω= 37.5 kip-in/ft Vn/Ω = 1.70 kip/ft

C PANELS
(Icr+Iu)/2 = 54.67 in /ft
4
Iu = 64.4 in4/ft ϕMno= 57.3 kip-in/ft ϕ Vn = 3.40 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 679 617 566 522 485 437 360 300 253 215 184 159 138 121 107
LRFD, ϕW 1358 1235 1132 1040 892 772 674 593 525 467 418 376 339 307 279
L/360 - - - - - 437 360 300 253 215 184 159 138 121 107
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3098 2960 2845 2814 2726 2649 2583 2524 2471 2470 2425 2385 2349 2315 2285
D PANEL

PAF Base Steel ≥ .25" 2418 2342 2279 2291 2241 2197 2158 2124 2094 2112 2086 2062 2040 2020 2002
PAF Base Steel ≥ 0.125" 2345 2275 2217 2234 2188 2147 2112 2081 2053 2073 2049 2027 2006 1988 1971
#12 Screw Base Steel ≥ .0385" 2353 2284 2226 2243 2196 2156 2120 2089 2061 2082 2057 2035 2015 1996 1979
Concrete + Deck = 31.1 psf Icr = 51.0 in4/ft Mno/Ω= 44.6 kip-in/ft Vn/Ω = 1.70 kip/ft
(Icr+Iu)/2 = 59.64 in4/ft Iu = 68.2 in4/ft ϕMno= 68.3 kip-in/ft ϕ Vn = 3.40 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 3090 4440 5430 7230 9930
12 in o.c. 3090 4440 5430 7230 9930
18 in o.c. 3090 4440 5430 7230 8790
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 119
TABLE OF CONTENTS

4.4 BH-36 Composite Deck


4 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.085yd3/100ft2

Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 6' - 6" 6' - 10" 7' - 9" 18 8' - 11" 10' - 6" 11' - 1"
20 7' - 10" 8' - 5" 9' - 3" 16 9' - 7" 11' - 10" 11' - 9"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 776 637 531 449 383 331 288 252 222 197 175 156 140 126 114
LRFD, ϕW 1242 1019 850 718 614 529 460 403 355 314 280 250 224 202 182
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2627 2563 2510 2481 2441 2407 2377 2350 2327 2317 2297 2279 2263 2249 2235
PAF Base Steel ≥ .25" 2311 2276 2247 2238 2216 2197 2180 2165 2151 2151 2139 2129 2120 2111 2104
PAF Base Steel ≥ 0.125" 2287 2254 2226 2220 2199 2180 2164 2150 2138 2138 2127 2118 2109 2101 2093
#12 Screw Base Steel ≥ .0385" 2264 2233 2207 2202 2182 2165 2150 2137 2125 2126 2116 2107 2099 2091 2084
Concrete + Deck = 34.0 psf Icr = 47.1 in4/ft Mno/Ω= 31.4 kip-in/ft Vn/Ω = 1.99 kip/ft
(Icr+Iu)/2 = 64.87 in4/ft Iu = 82.6 in4/ft ϕMno= 48.1 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 795 723 624 528 452 390 340 298 263 234 208 185 161 141 124
LRFD, ϕW 1457 1197 999 845 723 625 544 477 421 374 333 298 268 242 219
L/360 - - - - - - - - - - - 185 161 141 124
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2777 2699 2634 2603 2555 2512 2475 2443 2414 2404 2380 2358 2338 2320 2304
PAF Base Steel ≥ .25" 2392 2350 2314 2307 2280 2256 2235 2217 2200 2202 2188 2175 2163 2153 2143
PAF Base Steel ≥ 0.125" 2363 2323 2289 2285 2259 2236 2217 2199 2184 2186 2173 2161 2150 2140 2131
#12 Screw Base Steel ≥ .0385" 2338 2300 2269 2266 2241 2220 2201 2185 2170 2173 2161 2149 2139 2129 2121
Concrete + Deck = 34.3 psf Icr = 53.1 in4/ft Mno/Ω= 36.7 kip-in/ft Vn/Ω = 1.99 kip/ft
(Icr+Iu)/2 = 69.5 in4/ft Iu = 85.9 in4/ft ϕMno= 56.2 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 795 723 662 611 568 497 434 381 328 279 239 206 179 157 138
LRFD, ϕW 1590 1445 1267 1073 919 796 694 610 540 480 429 385 347 314 285
L/360 - - - - - - - - 328 279 239 206 179 157 138
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3089 2982 2893 2860 2792 2734 2682 2637 2597 2590 2556 2525 2498 2472 2449
PAF Base Steel ≥ .25" 2561 2503 2453 2454 2415 2382 2353 2327 2304 2312 2292 2274 2258 2243 2229
PAF Base Steel ≥ 0.125" 2523 2468 2421 2425 2388 2356 2329 2304 2283 2292 2273 2256 2240 2226 2213
#12 Screw Base Steel ≥ .0385" 2496 2443 2399 2404 2369 2339 2312 2289 2268 2278 2260 2243 2228 2215 2202
Concrete + Deck = 35.0 psf Icr = 63.0 in4/ft Mno/Ω= 46.2 kip-in/ft Vn/Ω = 1.99 kip/ft
(Icr+Iu)/2 = 77.32 in /ft
4
Iu = 91.6 in4/ft ϕMno= 70.7 kip-in/ft ϕ Vn = 3.97 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 795 723 662 611 568 530 497 424 357 304 261 225 196 171 151
LRFD, ϕW 1590 1445 1325 1223 1107 959 837 737 653 581 521 468 423 383 348
L/360 - - - - - - - 424 357 304 261 225 196 171 151
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3422 3284 3169 3138 3050 2974 2907 2848 2796 2794 2749 2709 2673 2639 2609
PAF Base Steel ≥ .25" 2742 2666 2603 2615 2565 2521 2482 2448 2418 2436 2410 2386 2364 2344 2326
PAF Base Steel ≥ 0.125" 2669 2599 2541 2559 2512 2471 2436 2405 2377 2397 2373 2351 2330 2312 2295
#12 Screw Base Steel ≥ .0385" 2677 2608 2550 2567 2520 2480 2444 2413 2385 2406 2381 2359 2339 2320 2303
Concrete + Deck = 35.7 psf Icr = 71.7 in4/ft Mno/Ω= 55.2 kip-in/ft Vn/Ω = 1.99 kip/ft
(Icr+Iu)/2 = 84.35 in4/ft Iu = 97.0 in4/ft ϕMno= 84.5 kip-in/ft ϕ Vn = 3.97 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. 3460 4810 5800 7600 10300
12 in o.c. 3460 4810 5800 7600 10300
18 in o.c. 3460 4810 5800 7600 8790

120 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

BH-36 Composite Deck 4.4

GENERAL INFORMATION
43⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.162yd3/100ft2
2 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 6' - 5" 6' - 9" 7' - 7" 18 8' - 8" 10' - 4" 10' - 11"
20 7' - 8" 8' - 4" 9' - 1" 16 9' - 5" 11' - 7" 11' - 7"

3W PANELS
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 850 698 582 492 420 363 315 276 243 216 192 172 154 139 125
LRFD, ϕW 1360 1116 931 787 672 580 505 442 390 345 307 275 246 222 200
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2789 2725 2672 2643 2603 2569 2539 2512 2489 2479 2459 2442 2425 2411 2397
PAF Base Steel ≥ .25" 2473 2438 2409 2400 2378 2359 2342 2327 2313 2313 2301 2291 2282 2273 2266
PAF Base Steel ≥ 0.125" 2449 2416 2388 2382 2361 2342 2326 2312 2300 2300 2289 2280 2271 2263 2255

2W PANELS
#12 Screw Base Steel ≥ .0385" 2426 2395 2369 2364 2344 2327 2312 2299 2287 2288 2278 2269 2261 2253 2246
Concrete + Deck = 36.3 psf Icr = 54.7 in4/ft Mno/Ω= 34.4 kip-in/ft Vn/Ω = 2.14 kip/ft
(Icr+Iu)/2 = 76.06 in4/ft Iu = 97.4 in4/ft ϕMno= 52.6 kip-in/ft ϕ Vn = 4.28 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 855 778 685 579 496 428 373 327 289 257 229 205 184 165 146
LRFD, ϕW 1597 1312 1095 927 793 685 597 524 462 411 366 328 295 266 241
L/360 - - - - - - - - - - - - - 165 146

B PANELS
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2939 2861 2796 2765 2717 2674 2637 2605 2576 2566 2542 2520 2500 2482 2466
PAF Base Steel ≥ .25" 2554 2512 2476 2469 2442 2418 2397 2379 2362 2364 2350 2337 2325 2315 2305
PAF Base Steel ≥ 0.125" 2525 2485 2451 2447 2421 2398 2379 2361 2346 2348 2335 2323 2312 2302 2293
#12 Screw Base Steel ≥ .0385" 2500 2463 2431 2428 2403 2382 2363 2347 2332 2335 2323 2311 2301 2291 2283
Concrete + Deck = 36.6 psf Icr = 61.7 in4/ft Mno/Ω= 40.2 kip-in/ft Vn/Ω = 2.14 kip/ft
(Icr+Iu)/2 = 81.45 in /ft
4
Iu = 101.2 in4/ft ϕMno= 61.5 kip-in/ft ϕ Vn = 4.28 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 855 778 713 658 611 547 477 419 371 327 280 242 210 184 162
LRFD, ϕW 1711 1555 1392 1179 1011 875 763 671 594 528 472 424 383 346 314
L/360 - - - - - - - - - 327 280 242 210 184 162
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3251 3144 3055 3022 2954 2896 2844 2799 2759 2752 2718 2687 2660 2634 2611
PAF Base Steel ≥ .25" 2724 2665 2615 2616 2577 2544 2515 2489 2466 2474 2454 2436 2420 2405 2391
PAF Base Steel ≥ 0.125" 2685 2630 2583 2587 2550 2518 2491 2466 2445 2454 2435 2418 2402 2388 2375
#12 Screw Base Steel ≥ .0385" 2658 2605 2561 2566 2531 2501 2474 2451 2430 2440 2422 2405 2390 2377 2364

C PANELS
Concrete + Deck = 37.3 psf Icr = 73.4 in4/ft Mno/Ω= 50.7 kip-in/ft Vn/Ω = 2.14 kip/ft
(Icr+Iu)/2 = 90.62 in4/ft Iu = 107.8 in4/ft ϕMno= 77.6 kip-in/ft ϕ Vn = 4.28 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 855 778 713 658 611 570 535 497 419 356 305 264 230 201 177
LRFD, ϕW 1711 1555 1426 1316 1219 1056 922 812 719 641 574 516 466 423 385
L/360 - - - - - - - 497 419 356 305 264 230 201 177
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3584 3446 3331 3300 3212 3136 3069 3010 2958 2956 2911 2871 2835 2801 2771
D PANEL

PAF Base Steel ≥ .25" 2904 2828 2765 2777 2727 2683 2644 2610 2580 2598 2572 2548 2526 2506 2488
PAF Base Steel ≥ 0.125" 2831 2761 2703 2721 2674 2633 2598 2567 2539 2560 2535 2513 2492 2474 2457
#12 Screw Base Steel ≥ .0385" 2839 2770 2712 2729 2682 2642 2606 2575 2547 2568 2543 2521 2501 2482 2465
Concrete + Deck = 37.9 psf Icr = 83.7 in4/ft Mno/Ω= 60.7 kip-in/ft Vn/Ω = 2.14 kip/ft
(Icr+Iu)/2 = 98.88 in /ft
4
Iu = 114.0 in4/ft ϕMno= 92.9 kip-in/ft ϕ Vn = 4.28 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. n/a 4990 5980 7780 10480
12 in o.c. n/a 4990 5980 7780 10480
18 in o.c. n/a 4990 5980 7780 8790
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 121
TABLE OF CONTENTS

4.4 BH-36 Composite Deck


5 11⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.452yd3/100ft2
3 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 6' - 0" 6' - 6" 7' - 1" 18 8' - 2" 9' - 8" 10' - 2"
20 7' - 2" 7' - 10" 8' - 5" 16 8' - 10" 10' - 10" 10' - 11"
GA Vertical Load Span (in) 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1097 933 778 658 563 486 423 371 327 290 259 231 208 187 169
LRFD, ϕW 1817 1492 1245 1053 901 778 677 594 524 464 414 370 333 300 271
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3396 3332 3279 3251 3211 3177 3146 3120 3096 3086 3067 3049 3033 3018 3005
PAF Base Steel ≥ .25" 3081 3046 3016 3008 2986 2966 2949 2934 2921 2920 2909 2899 2890 2881 2873
PAF Base Steel ≥ 0.125" 3056 3023 2996 2989 2968 2950 2934 2920 2907 2907 2897 2887 2878 2870 2863
#12 Screw Base Steel ≥ .0385" 3034 3003 2977 2972 2952 2935 2920 2907 2895 2896 2886 2876 2868 2861 2854
Concrete + Deck = 44.9 psf Icr = 89.2 in4/ft Mno/Ω= 45.9 kip-in/ft Vn/Ω = 2.74 kip/ft
(Icr+Iu)/2 = 128.9 in4/ft Iu = 168.7 in4/ft ϕMno= 70.2 kip-in/ft ϕ Vn = 5.49 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1097 997 914 778 666 576 502 441 389 346 309 277 249 225 204
LRFD, ϕW 2140 1759 1469 1244 1065 921 803 705 623 554 494 443 399 361 327
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3547 3469 3404 3373 3324 3282 3245 3212 3183 3174 3150 3128 3108 3090 3073
PAF Base Steel ≥ .25" 3162 3119 3083 3077 3049 3026 3005 2986 2970 2971 2957 2945 2933 2922 2913
PAF Base Steel ≥ 0.125" 3133 3093 3059 3055 3029 3006 2986 2969 2953 2956 2943 2931 2920 2910 2901
#12 Screw Base Steel ≥ .0385" 3108 3070 3038 3036 3011 2990 2971 2954 2940 2943 2930 2919 2909 2899 2890
Concrete + Deck = 45.2 psf Icr = 101.1 in4/ft Mno/Ω= 53.8 kip-in/ft Vn/Ω = 2.74 kip/ft
(Icr+Iu)/2 = 137.9 in4/ft Iu = 174.7 in4/ft ϕMno= 82.3 kip-in/ft ϕ Vn = 5.49 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1097 997 914 844 784 731 646 568 503 448 401 361 326 295 268
LRFD, ϕW 2194 1995 1829 1594 1367 1184 1034 909 805 717 642 577 521 472 429
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3859 3752 3663 3630 3562 3503 3452 3407 3367 3359 3326 3295 3267 3242 3219
PAF Base Steel ≥ .25" 3331 3272 3223 3224 3185 3152 3122 3096 3074 3082 3062 3044 3027 3012 2999
PAF Base Steel ≥ 0.125" 3293 3237 3191 3194 3158 3126 3098 3074 3052 3062 3043 3026 3010 2996 2983
#12 Screw Base Steel ≥ .0385" 3266 3213 3169 3174 3139 3108 3082 3058 3037 3048 3029 3013 2998 2984 2972
Concrete + Deck = 45.9 psf Icr = 121.2 in4/ft Mno/Ω= 68.3 kip-in/ft Vn/Ω = 2.74 kip/ft
(Icr+Iu)/2 = 153.4 in /ft
4
Iu = 185.6 in4/ft ϕMno= 104.5 kip-in/ft ϕ Vn = 5.49 kip/ft
Vertical Load Span (in) 5'-0" 5'-6"
6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1097 997 914 844 784 731 686 645 610 546 489 441 388 340 299
LRFD, ϕW 2194 1995 1829 1688 1567 1436 1255 1105 980 874 783 705 637 578 527
L/360 - - - - - - - - - - - - 388 340 299
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4191 4053 3939 3907 3819 3743 3676 3617 3565 3563 3519 3479 3442 3409 3378
PAF Base Steel ≥ .25" 3512 3436 3373 3385 3334 3290 3252 3218 3188 3206 3179 3155 3134 3114 3095
PAF Base Steel ≥ 0.125" 3438 3369 3311 3328 3281 3241 3206 3174 3147 3167 3143 3120 3100 3082 3065
#12 Screw Base Steel ≥ .0385" 3447 3377 3320 3337 3290 3249 3214 3183 3155 3175 3151 3128 3108 3090 3073
Concrete + Deck = 46.5 psf Icr = 138.9 in4/ft Mno/Ω= 82.2 kip-in/ft Vn/Ω = 2.74 kip/ft
(Icr+Iu)/2 = 167.4 in4/ft Iu = 195.8 in4/ft ϕMno= 125.8 kip-in/ft ϕ Vn = 5.49 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
6 in o.c. n/a 5680 6670 8470 11170
12 in o.c. n/a 5680 6670 8470 11170
18 in o.c. n/a 5680 6670 8470 8790
122 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 123


TABLE OF CONTENTS

5.1 NH-32
3-7/8” 4-1/8” 8” 3-7/8” 4-1/8” 8”

3” 3”

2-1/8” 2-1/8”

32” 32”
NH-32 Profile NHN-32 Profile

36/5

32/5 Attachment Pattern

N Series Embossment
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
22 1.97 0.0299 50 65 0.569 0.814 1.68 0.483 1.195
20 2.35 0.0359 50 65 0.681 0.968 1.68 0.576 1.193
18 3.10 0.0478 50 65 0.902 1.275 1.69 0.755 1.189
16 3.86 0.0598 50 65 1.123 1.575 1.69 0.931 1.185

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending
Distance to Distance to Uniform Load Only
Section N.A. from Section N.A. from Moment of Moment of
Gage Area Modulus Bottom Modulus Bottom Inertia Inertia Id = (2Ie+Ig)/3
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
22 0.272 0.349 1.37 0.402 1.78 0.626 0.758 0.689 0.776
20 0.372 0.446 1.41 0.505 1.76 0.788 0.934 0.848 0.945
18 0.604 0.661 1.48 0.715 1.72 1.121 1.275 1.173 1.275
16 0.871 0.879 1.54 0.927 1.70 1.474 1.575 1.508 1.575

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 1.5" 2" 3" 1" 1.5" 2" 3"
End 500 566 622 716 764 866 952 1095
22
Interior 876 973 1056 1194 1303 1448 1570 1776
End 709 799 876 1004 1084 1223 1340 1536
20
Interior 1240 1371 1482 1669 1844 2040 2205 2482
End 1221 1367 1490 1697 1868 2092 2280 2597
18
Interior 2133 2343 2519 2816 3173 3485 3748 4189
End 1864 2076 2254 2554 2852 3176 3449 3907
16
Interior 3260 3560 3814 4239 4849 5296 5673 6305
Web Crippling Constraints h=3.06" r=0.125" θ=70.7º

124 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NHF-32 5.2

GENERAL INFORMATION
3-7/8” 4-1/8” 8”

3”
36/5
2-1/8”
32/5 Attachment Pattern
32”
NHF-32 Profile

3W PANELS
Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 3.96 0.0359 / 0.036 50 65 1.114 1.740 1.07 0.867 1.250

2W PANELS
20/18 4.44 0.0359 / 0.047 50 65 1.254 1.877 0.96 0.884 1.223
20/16 4.96 0.0359 / 0.059 50 65 1.406 1.999 0.87 0.899 1.192
18/20 4.71 0.0478 / 0.036 50 65 1.330 2.143 1.19 1.129 1.269
18/18 5.19 0.0478 / 0.047 50 65 1.470 2.316 1.09 1.153 1.255
18/16 5.71 0.0478 / 0.059 50 65 1.622 2.474 1.00 1.173 1.235
16/20 5.47 0.0598 / 0.036 50 65 1.547 2.522 1.27 1.385 1.277
16/18 5.95 0.0598 / 0.047 50 65 1.687 2.725 1.18 1.415 1.271
16/16 6.47 0.0598 / 0.059 50 65 1.839 2.914 1.10 1.442 1.259

B PANELS
Effective Section Modulus at Fy
Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie + I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft

N PANELS
20/20 0.547 0.488 0.76 0.808 1.39 1.381 1.454 1.501 1.549
20/18 0.622 0.490 0.66 0.838 1.24 1.480 1.623 1.612 1.708
20/16 0.729 0.522 0.62 0.863 1.11 1.515 1.816 1.676 1.877
18/20 0.784 0.798 0.99 1.057 1.45 1.835 1.839 1.938 1.940
18/18 0.859 0.816 0.90 1.093 1.33 1.972 2.019 2.087 2.118
18/16 0.966 0.810 0.81 1.123 1.22 2.107 2.234 2.230 2.314
16/20 1.057 1.073 1.13 1.306 1.49 2.316 2.218 2.385 2.319
16/18 1.132 1.098 1.04 1.346 1.39 2.495 2.405 2.572 2.512

C PANELS
16/16 1.238 1.119 0.96 1.380 1.30 2.661 2.636 2.746 2.729

D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 125


TABLE OF CONTENTS

5.3 NHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

NHF-36 Cellular Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 42.0 12' - 5" 14' - 8" 13' - 3"
20/18 42.4 13' - 0" 15' - 2" 13' - 4"
20/16 42.9 12' - 10" 15' - 1" 13' - 4"
18/20 42.6 14' - 4" 16' - 7" 13' - 4"
5 0.979 18/18 43.1 14' - 7" 17' - 7" 13' - 4"
18/16 43.6 14' - 9" 18' - 0" 13' - 4"
16/20 43.3 15' - 1" 18' - 0" 13' - 4"
16/18 43.8 15' - 4" 18' - 4" 13' - 4"
16/16 44.3 15' - 6" 18' - 9" 13' - 4"
20/20 54.0 11' - 4" 13' - 5" 12' - 2"
20/18 54.5 11' - 10" 13' - 11" 12' - 8"
20/16 55.0 11' - 9" 13' - 10" 12' - 6"
18/20 54.7 13' - 6" 15' - 3" 13' - 4"
6 1.288 18/18 55.2 13' - 9" 16' - 4" 13' - 4"
18/16 55.7 13' - 11" 16' - 7" 13' - 4"
16/20 55.4 14' - 2" 16' - 9" 13' - 4"
16/18 55.8 14' - 5" 17' - 4" 13' - 4"
16/16 56.4 14' - 8" 17' - 8" 13' - 4"
20/20 60.1 10' - 10" 12' - 11" 11' - 9"
20/18 60.6 11' - 4" 13' - 5" 12' - 2"
20/16 61.1 11' - 3" 13' - 4" 12' - 1"
6 1/2
18/20 60.7 13' - 2" 14' - 8" 13' - 4"
1.442 18/18 61.2 13' - 5" 15' - 9" 13' - 4"
1 Hour
18/16 61.7 13' - 7" 16' - 0" 13' - 4"
Fire Rating
16/20 61.4 13' - 10" 16' - 2" 13' - 4"
16/18 61.9 14' - 1" 16' - 11" 13' - 4"
16/16 62.4 14' - 4" 17' - 3" 13' - 4"
20/20 72.2 10' - 1" 12' - 1" 10' - 11"
20/18 72.6 10' - 7" 12' - 7" 11' - 4"
20/16 73.2 10' - 6" 12' - 6" 11' - 3"
7 1/2
18/20 72.8 12' - 8" 13' - 9" 13' - 4"
1.751 18/18 73.3 12' - 10" 14' - 9" 13' - 4"
2 Hour
18/16 73.8 13' - 0" 15' - 0" 13' - 4"
Fire Rating
16/20 73.5 13' - 3" 15' - 1" 13' - 4"
16/18 74.0 13' - 6" 16' - 2" 13' - 4"
16/16 74.5 13' - 8" 16' - 6" 13' - 4"
20/20 81.2 9' - 7" 11' - 7" 10' - 6"
20/18 81.7 10' - 1" 12' - 0" 10' - 10"
20/16 82.2 10' - 0" 11' - 11" 10' - 10"
8 1/4
18/20 81.9 12' - 3" 13' - 2" 12' - 11"
1.982 18/18 82.4 12' - 4" 14' - 1" 13' - 0"
3 Hour
18/16 82.9 12' - 5" 14' - 4" 13' - 1"
Fire Rating
16/20 82.6 12' - 11" 14' - 5" 13' - 4"
16/18 83.0 13' - 2" 15' - 6" 13' - 4"
16/16 83.5 13' - 4" 15' - 10" 13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

126 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NHF-36 Cellular Composite Deck 5.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
NHF-36 Cellular Shoring Table
110 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 32.7 13' - 9" 15' - 11" 13' - 4"
20/18 33.2 14' - 5" 16' - 7" 13' - 4"
20/16 33.7 14' - 3" 16' - 5" 13' - 4"
18/20 33.4 15' - 4" 18' - 1" 13' - 4"

2W PANELS
5 0.979 18/18 33.8 15' - 6" 18' - 9" 13' - 4"
18/16 34.4 15' - 9" 19' - 2" 13' - 4"
16/20 34.0 16' - 0" 19' - 2" 13' - 4"
16/18 34.5 16' - 3" 19' - 6" 13' - 4"
16/16 35.0 16' - 6" 19' - 11" 13' - 4"
20/20 37.3 13' - 1" 15' - 4" 13' - 4"
20/18 37.8 13' - 8" 15' - 11" 13' - 4"
20/16 38.3 13' - 7" 15' - 9" 13' - 4"
5 1/2

B PANELS
18/20 37.9 14' - 10" 17' - 5" 13' - 4"
1.133 18/18 38.4 15' - 1" 18' - 3" 13' - 4"
1 Hour
18/16 38.9 15' - 3" 18' - 7" 13' - 4"
Fire Rating
16/20 38.6 15' - 7" 18' - 7" 13' - 4"
16/18 39.1 15' - 10" 19' - 0" 13' - 4"
16/16 39.6 16' - 0" 19' - 4" 13' - 4"
20/20 41.9 12' - 7" 14' - 9" 13' - 4"
20/18 42.3 13' - 1" 15' - 4" 13' - 4"

N PANELS
20/16 42.9 13' - 0" 15' - 2" 13' - 4"
18/20 42.5 14' - 5" 16' - 9" 13' - 4"
6 1.288 18/18 43.0 14' - 8" 17' - 9" 13' - 4"
18/16 43.5 14' - 10" 18' - 2" 13' - 4"
16/20 43.2 15' - 2" 18' - 1" 13' - 4"
16/18 43.7 15' - 5" 18' - 6" 13' - 4"
16/16 44.2 15' - 7" 18' - 10" 13' - 4"
20/20 44.2 12' - 4" 14' - 6" 13' - 2"

C PANELS
20/18 44.6 12' - 10" 15' - 0" 13' - 4"
20/16 45.2 12' - 9" 14' - 11" 13' - 4"
6 1/4
18/20 44.8 14' - 3" 16' - 6" 13' - 4"
1.365 18/18 45.3 14' - 6" 17' - 6" 13' - 4"
2 Hour
18/16 45.8 14' - 8" 17' - 11" 13' - 4"
Fire Rating
16/20 45.5 14' - 11" 17' - 11" 13' - 4"
16/18 46.0 15' - 2" 18' - 3" 13' - 4"
16/16 46.5 15' - 5" 18' - 7" 13' - 4"
20/20 52.8 11' - 6" 13' - 8" 12' - 4"
D PANEL

20/18 53.2 12' - 0" 14' - 2" 12' - 10"


20/16 53.7 11' - 11" 14' - 1" 12' - 9"
7 3/16
18/20 53.4 13' - 8" 15' - 6" 13' - 4"
1.654 18/18 53.9 13' - 11" 16' - 7" 13' - 4"
3 Hour
18/16 54.4 14' - 1" 16' - 10" 13' - 4"
Fire Rating
16/20 54.1 14' - 4" 17' - 0" 13' - 4"
16/18 54.6 14' - 7" 17' - 6" 13' - 4"
ACUSTADEK®

16/16 55.1 14' - 9" 17' - 11" 13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 127


TABLE OF CONTENTS

5.3 NH-32 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 0.979yd3/100ft2

Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 9' - 8" 10' - 10" 11' - 5" 18 12' - 8" 14' - 11" 15' - 2"
20 11' - 3" 12' - 7" 13' - 0" 16 13' - 6" 16' - 9" 15' - 11"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 277 242 212 188 166 148 132 118 106 96 86 78 70 63 57
LRFD, ϕW 443 387 340 300 266 237 211 189 170 153 138 124 112 101 91
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2436 2406 2380 2368 2346 2326 2308 2292 2277 2272 2259 2247 2235 2225 2215
PAF Base Steel ≥ .25" 2214 2197 2183 2181 2168 2157 2147 2138 2129 2130 2122 2115 2109 2103 2097
PAF Base Steel ≥ 0.125" 2197 2181 2167 2166 2155 2144 2134 2126 2118 2119 2112 2105 2099 2093 2088
#12 Screw Base Steel ≥ .0385" 2181 2166 2153 2153 2142 2132 2123 2115 2107 2109 2102 2096 2090 2084 2079
Concrete + Deck = 40.3 psf Icr = 38.1 in4/ft Mno/Ω= 30.8 kip-in/ft Vn/Ω = 3.12 kip/ft
(Icr+Iu)/2 = 65.45 in4/ft Iu = 92.8 in4/ft ϕMno= 47.2 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 329 288 253 224 200 178 160 143 129 117 106 96 87 79 72
LRFD, ϕW 526 461 406 359 319 285 255 229 207 187 169 153 139 126 115
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2543 2507 2474 2462 2435 2411 2389 2369 2350 2346 2330 2315 2301 2288 2276
PAF Base Steel ≥ .25" 2272 2252 2234 2234 2219 2205 2192 2181 2170 2173 2163 2154 2146 2139 2132
PAF Base Steel ≥ 0.125" 2252 2233 2216 2217 2202 2189 2177 2166 2156 2159 2151 2142 2135 2127 2121
#12 Screw Base Steel ≥ .0385" 2235 2216 2200 2202 2188 2176 2165 2154 2145 2148 2140 2132 2125 2118 2111
Concrete + Deck = 40.7 psf Icr = 43.5 in4/ft Mno/Ω= 36.1 kip-in/ft Vn/Ω = 3.12 kip/ft
(Icr+Iu)/2 = 69.59 in /ft
4
Iu = 95.7 in4/ft ϕMno= 55.2 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 425 373 329 292 261 234 210 190 172 156 142 129 118 108 99
LRFD, ϕW 680 597 527 468 417 374 336 303 275 249 227 207 189 172 158
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2767 2717 2673 2662 2624 2590 2560 2532 2506 2504 2482 2461 2441 2423 2406
PAF Base Steel ≥ .25" 2396 2368 2343 2349 2327 2308 2290 2274 2259 2267 2253 2241 2229 2218 2208
PAF Base Steel ≥ 0.125" 2369 2343 2319 2326 2306 2287 2270 2255 2241 2250 2237 2225 2214 2203 2194
#12 Screw Base Steel ≥ .0385" 2351 2325 2302 2311 2291 2273 2257 2242 2228 2238 2225 2214 2203 2193 2184
Concrete + Deck = 41.4 psf Icr = 52.9 in4/ft Mno/Ω= 45.8 kip-in/ft Vn/Ω = 3.12 kip/ft
(Icr+Iu)/2 = 77.02 in4/ft Iu = 101.1 in4/ft ϕMno= 70.1 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 518 456 403 358 320 288 259 235 213 194 177 160 143 129 116
LRFD, ϕW 829 729 645 573 513 460 415 375 340 310 283 258 237 217 200
L/360 - - - - - - - - - - - 160 143 129 116
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3009 2944 2886 2880 2831 2787 2747 2710 2676 2680 2650 2622 2597 2573 2550
PAF Base Steel ≥ .25" 2532 2495 2462 2478 2449 2423 2399 2378 2358 2374 2356 2339 2324 2309 2296
PAF Base Steel ≥ 0.125" 2480 2446 2416 2434 2407 2383 2362 2342 2323 2341 2324 2308 2294 2280 2268
#12 Screw Base Steel ≥ .0385" 2492 2458 2428 2446 2420 2396 2374 2354 2336 2353 2336 2321 2306 2293 2280
Concrete + Deck = 42.2 psf Icr = 61.6 in4/ft Mno/Ω= 55.2 kip-in/ft Vn/Ω = 3.12 kip/ft
(Icr+Iu)/2 = 83.94 in4/ft Iu = 106.3 in4/ft ϕMno= 84.5 kip-in/ft ϕ Vn = 4.67 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. 3200 4550 5540 7340 10040
16 in o.c. 3200 4550 5540 7340 9890
24 in o.c. 3200 4550 5540 6590 6590

128 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NH-32 Composite Deck 5.3

GENERAL INFORMATION
51⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.133yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 9' - 3" 10' - 4" 10' - 10" 18 12' - 4" 14' - 3" 14' - 9"
20 10' - 8" 12' - 0" 12' - 5" 16 13' - 1" 16' - 1" 15' - 5"
GA

3W PANELS
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 328 287 252 223 198 176 157 141 127 114 103 93 84 76 69
LRFD, ϕW 525 459 403 356 316 282 252 226 203 182 164 148 134 121 110
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2853 2828 2805 2797 2778 2761 2746 2732 2719 2715 2704 2694 2684 2675 2667
PAF Base Steel ≥ .25" 2666 2652 2639 2639 2628 2619 2610 2602 2594 2596 2589 2583 2577 2572 2567
PAF Base Steel ≥ 0.125" 2652 2638 2626 2627 2617 2607 2599 2591 2584 2587 2580 2574 2569 2564 2559

2W PANELS
#12 Screw Base Steel ≥ .0385" 2638 2626 2614 2616 2606 2597 2589 2582 2575 2578 2572 2566 2561 2557 2552
Concrete + Deck = 46.3 psf Icr = 49.7 in4/ft Mno/Ω= 36.4 kip-in/ft Vn/Ω = 3.58 kip/ft
(Icr+Iu)/2 = 86.16 in4/ft Iu = 122.6 in4/ft ϕMno= 55.8 kip-in/ft ϕ Vn = 5.37 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 390 342 301 267 237 212 190 171 154 139 126 114 104 94 86
LRFD, ϕW 624 547 482 427 379 339 304 273 246 223 202 183 166 151 138
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 2945 2914 2887 2878 2855 2834 2815 2798 2782 2780 2766 2753 2741 2730 2719
PAF Base Steel ≥ .25" 2717 2700 2684 2686 2673 2661 2650 2639 2630 2634 2626 2618 2611 2604 2598
PAF Base Steel ≥ 0.125" 2700 2683 2669 2672 2659 2647 2637 2627 2619 2623 2615 2608 2601 2595 2589
#12 Screw Base Steel ≥ .0385" 2685 2670 2656 2659 2647 2636 2626 2617 2609 2614 2606 2599 2592 2586 2581
Concrete + Deck = 46.7 psf Icr = 56.7 in4/ft Mno/Ω= 42.7 kip-in/ft Vn/Ω = 3.58 kip/ft
(Icr+Iu)/2 = 91.51 in /ft
4
Iu = 126.3 in4/ft ϕMno= 65.3 kip-in/ft ϕ Vn = 5.37 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 505 443 391 348 310 278 250 226 205 186 169 154 141 129 118
LRFD, ϕW 808 709 626 556 496 445 400 362 327 297 271 247 225 206 189
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3139 3096 3058 3052 3020 2991 2964 2940 2918 2919 2899 2881 2864 2848 2833
PAF Base Steel ≥ .25" 2827 2802 2780 2789 2770 2753 2737 2722 2709 2719 2707 2696 2685 2676 2667
PAF Base Steel ≥ 0.125" 2804 2781 2760 2770 2752 2735 2720 2707 2694 2704 2693 2682 2672 2663 2655
#12 Screw Base Steel ≥ .0385" 2788 2766 2746 2757 2739 2723 2709 2696 2684 2694 2683 2673 2663 2654 2646
Concrete + Deck = 47.5 psf Icr = 69.1 in4/ft Mno/Ω= 54.3 kip-in/ft Vn/Ω = 3.58 kip/ft

C PANELS
(Icr+Iu)/2 = 101.13 in4/ft Iu = 133.2 in4/ft ϕMno= 83.0 kip-in/ft ϕ Vn = 5.37 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 616 541 479 426 381 342 309 279 254 231 211 193 177 162 149
LRFD, ϕW 985 866 766 682 610 548 494 447 406 369 337 308 283 260 239
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3351 3294 3244 3245 3202 3164 3129 3097 3067 3075 3049 3024 3002 2981 2961
D PANEL

PAF Base Steel ≥ .25" 2948 2916 2887 2906 2880 2857 2836 2817 2799 2817 2801 2786 2772 2759 2747
PAF Base Steel ≥ 0.125" 2905 2875 2848 2869 2845 2824 2804 2786 2770 2789 2774 2760 2747 2735 2723
#12 Screw Base Steel ≥ .0385" 2917 2887 2860 2881 2858 2836 2816 2799 2782 2801 2786 2772 2759 2747 2735
Concrete + Deck = 48.2 psf Icr = 80.4 in4/ft Mno/Ω= 65.5 kip-in/ft Vn/Ω = 3.58 kip/ft
(Icr+Iu)/2 = 110.05 in4/ft Iu = 139.7 in4/ft ϕMno= 100.2 kip-in/ft ϕ Vn = 5.37 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
ACUSTADEK®

8 in o.c. 3700 5050 6040 7840 10540


16 in o.c. 3700 5050 6040 7840 9890
24 in o.c. 3700 5050 6040 6590 6590

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 129


TABLE OF CONTENTS

5.3 NH-32 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.288yd3/100ft2

Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 8' - 10" 9' - 11" 10' - 4" 18 11' - 11" 13' - 8" 14' - 1"
20 10' - 3" 11' - 6" 11' - 11" 16 12' - 8" 15' - 6" 15' - 0"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 383 335 294 260 231 206 184 165 148 134 121 109 99 89 81
LRFD, ϕW 613 536 471 416 370 329 295 264 238 214 193 174 158 143 129
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3417 3387 3361 3348 3327 3307 3289 3273 3258 3253 3240 3227 3216 3206 3196
PAF Base Steel ≥ .25" 3195 3178 3164 3162 3149 3138 3128 3118 3110 3111 3103 3096 3089 3083 3078
PAF Base Steel ≥ 0.125" 3178 3162 3148 3147 3135 3125 3115 3106 3098 3100 3092 3086 3080 3074 3069
#12 Screw Base Steel ≥ .0385" 3162 3147 3134 3134 3123 3113 3104 3095 3088 3089 3083 3076 3071 3065 3060
Concrete + Deck = 52.4 psf Icr = 63.3 in4/ft Mno/Ω= 42.4 kip-in/ft Vn/Ω = 4.07 kip/ft
(Icr+Iu)/2 = 110.95 in4/ft Iu = 158.6 in4/ft ϕMno= 64.9 kip-in/ft ϕ Vn = 6.10 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 456 399 352 312 277 248 222 200 181 163 148 134 122 111 101
LRFD, ϕW 729 639 563 499 444 397 356 320 289 261 237 215 195 178 162
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3524 3488 3455 3443 3416 3392 3370 3350 3331 3327 3311 3296 3282 3269 3257
PAF Base Steel ≥ .25" 3253 3233 3215 3215 3200 3186 3173 3161 3151 3154 3144 3135 3127 3120 3112
PAF Base Steel ≥ 0.125" 3233 3214 3197 3198 3183 3170 3158 3147 3137 3140 3131 3123 3115 3108 3102
#12 Screw Base Steel ≥ .0385" 3215 3197 3181 3183 3169 3157 3145 3135 3126 3129 3121 3113 3105 3099 3092
Concrete + Deck = 52.8 psf Icr = 72.4 in4/ft Mno/Ω= 49.7 kip-in/ft Vn/Ω = 4.07 kip/ft
(Icr+Iu)/2 = 117.76 in /ft
4
Iu = 163.2 in4/ft ϕMno= 76.1 kip-in/ft ϕ Vn = 6.10 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 590 518 458 407 363 326 293 265 240 218 199 181 166 152 139
LRFD, ϕW 945 830 733 651 582 521 469 424 384 349 318 290 265 243 223
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3748 3698 3653 3642 3605 3571 3541 3513 3487 3485 3462 3441 3422 3404 3387
PAF Base Steel ≥ .25" 3377 3349 3324 3330 3308 3289 3271 3254 3240 3248 3234 3222 3210 3199 3189
PAF Base Steel ≥ 0.125" 3350 3323 3300 3307 3287 3268 3251 3236 3222 3230 3218 3206 3195 3184 3175
#12 Screw Base Steel ≥ .0385" 3331 3306 3283 3291 3272 3254 3237 3223 3209 3218 3206 3195 3184 3174 3165
Concrete + Deck = 53.5 psf Icr = 88.3 in4/ft Mno/Ω= 63.3 kip-in/ft Vn/Ω = 4.07 kip/ft
(Icr+Iu)/2 = 130.01 in4/ft Iu = 171.7 in4/ft ϕMno= 96.9 kip-in/ft ϕ Vn = 6.10 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 721 634 561 499 447 401 362 328 298 271 248 227 208 191 176
LRFD, ϕW 1153 1014 898 799 715 642 579 525 476 434 396 363 333 306 281
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3990 3925 3867 3861 3812 3768 3728 3691 3657 3661 3631 3603 3577 3554 3531
PAF Base Steel ≥ .25" 3513 3476 3443 3459 3430 3404 3380 3359 3339 3355 3337 3320 3304 3290 3276
PAF Base Steel ≥ 0.125" 3461 3427 3397 3415 3388 3364 3342 3322 3304 3322 3305 3289 3275 3261 3249
#12 Screw Base Steel ≥ .0385" 3473 3439 3409 3427 3400 3376 3355 3335 3316 3334 3317 3301 3287 3273 3261
Concrete + Deck = 54.3 psf Icr = 102.7 in4/ft Mno/Ω= 76.5 kip-in/ft Vn/Ω = 4.07 kip/ft
(Icr+Iu)/2 = 141.35 in4/ft Iu = 180.0 in4/ft ϕMno= 117.0 kip-in/ft ϕ Vn = 6.10 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. 4190 5540 6530 8330 11030
16 in o.c. 4190 5540 6530 8330 9890
24 in o.c. 4190 5540 6530 6590 6590

130 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NH-32 Composite Deck 5.3

GENERAL INFORMATION
6 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.442yd3/100ft2
1 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 8' - 6" 9' - 7" 9' - 11" 18 11' - 8" 13' - 2" 13' - 7"
20 9' - 10" 11' - 1" 11' - 6" 16 12' - 4" 14' - 11" 14' - 8"

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 441 385 339 300 266 237 212 191 171 155 140 126 114 104 94
LRFD, ϕW 705 616 542 479 426 380 340 305 274 247 223 202 183 166 150
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3907 3878 3851 3839 3817 3797 3780 3763 3748 3743 3730 3718 3707 3696 3686
PAF Base Steel ≥ .25" 3685 3669 3654 3652 3640 3628 3618 3609 3600 3601 3593 3586 3580 3574 3568
PAF Base Steel ≥ 0.125" 3668 3652 3639 3638 3626 3615 3606 3597 3589 3590 3583 3576 3570 3564 3559

2W PANELS
#12 Screw Base Steel ≥ .0385" 3652 3638 3625 3624 3613 3603 3594 3586 3578 3580 3573 3567 3561 3556 3550
Concrete + Deck = 58.4 psf Icr = 79.0 in4/ft Mno/Ω= 48.6 kip-in/ft Vn/Ω = 4.58 kip/ft
(Icr+Iu)/2 = 140.24 in4/ft Iu = 201.5 in4/ft ϕMno= 74.4 kip-in/ft ϕ Vn = 6.74 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 524 460 405 359 320 286 257 231 209 189 171 156 142 129 118
LRFD, ϕW 839 735 648 575 512 458 411 370 334 302 274 249 226 206 188
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 4014 3978 3946 3933 3906 3882 3860 3840 3822 3817 3801 3786 3772 3759 3747
PAF Base Steel ≥ .25" 3744 3723 3705 3705 3690 3676 3663 3652 3641 3644 3634 3626 3618 3610 3603
PAF Base Steel ≥ 0.125" 3723 3704 3687 3688 3674 3660 3648 3638 3628 3631 3622 3614 3606 3599 3592
#12 Screw Base Steel ≥ .0385" 3706 3688 3672 3673 3660 3647 3636 3626 3616 3620 3611 3603 3596 3589 3583
Concrete + Deck = 58.8 psf Icr = 90.4 in4/ft Mno/Ω= 57.1 kip-in/ft Vn/Ω = 4.58 kip/ft
(Icr+Iu)/2 = 148.75 in4/ft Iu = 207.1 in4/ft ϕMno= 87.3 kip-in/ft ϕ Vn = 6.88 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 681 598 528 470 420 376 339 306 278 252 230 210 192 176 162
LRFD, ϕW 1089 956 845 751 671 602 542 490 444 404 368 336 307 282 259
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 4239 4188 4144 4133 4095 4062 4031 4003 3977 3976 3953 3932 3912 3894 3877
PAF Base Steel ≥ .25" 3868 3839 3814 3820 3799 3779 3761 3745 3730 3738 3725 3712 3700 3690 3679
PAF Base Steel ≥ 0.125" 3841 3814 3790 3798 3777 3758 3742 3726 3712 3721 3708 3696 3685 3675 3665
#12 Screw Base Steel ≥ .0385" 3822 3796 3773 3782 3762 3744 3728 3713 3699 3709 3696 3685 3674 3664 3655
Concrete + Deck = 59.6 psf Icr = 110.5 in4/ft Mno/Ω= 72.8 kip-in/ft Vn/Ω = 4.58 kip/ft

C PANELS
(Icr+Iu)/2 = 164.08 in /ft
4
Iu = 217.7 in4/ft ϕMno= 111.4 kip-in/ft ϕ Vn = 6.88 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 832 732 648 577 516 464 419 379 345 314 287 263 241 222 204
LRFD, ϕW 1331 1171 1037 923 826 742 670 607 551 502 459 420 386 355 327
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 4481 4416 4358 4351 4302 4258 4218 4181 4148 4151 4121 4094 4068 4044 4022
D PANEL

PAF Base Steel ≥ .25" 4003 3966 3933 3949 3920 3894 3871 3849 3829 3845 3827 3810 3795 3780 3767
PAF Base Steel ≥ 0.125" 3951 3917 3887 3905 3879 3855 3833 3813 3795 3812 3795 3780 3765 3752 3739
#12 Screw Base Steel ≥ .0385" 3963 3930 3899 3917 3891 3867 3845 3825 3807 3824 3807 3792 3777 3764 3751
Concrete + Deck = 60.3 psf Icr = 128.7 in4/ft Mno/Ω= 88.1 kip-in/ft Vn/Ω = 4.58 kip/ft
(Icr+Iu)/2 = 178.27 in4/ft Iu = 227.8 in4/ft ϕMno= 134.7 kip-in/ft ϕ Vn = 6.88 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. n/a 6030 7020 8820 11520
16 in o.c. n/a 6030 7020 8820 9890
24 in o.c. n/a 6030 6590 6590 6590

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 131


TABLE OF CONTENTS

5.3 NH-32 Composite Deck


7 1⁄2" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.751yd3/100ft2
2 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 7' - 11" 8' - 11" 9' - 3" 18 11' - 1" 12' - 3" 12' - 8"
20 9' - 2" 10' - 4" 10' - 8" 16 11' - 10" 13' - 11" 14' - 0"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 561 491 432 382 340 304 272 244 220 199 180 163 148 134 122
LRFD, ϕW 898 786 692 612 544 486 435 391 352 318 287 260 236 214 195
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 4888 4858 4832 4820 4798 4778 4760 4744 4729 4724 4711 4699 4688 4677 4667
PAF Base Steel ≥ .25" 4666 4650 4635 4633 4621 4609 4599 4590 4581 4582 4574 4567 4561 4555 4549
PAF Base Steel ≥ 0.125" 4649 4633 4619 4618 4607 4596 4587 4578 4570 4571 4564 4557 4551 4545 4540
#12 Screw Base Steel ≥ .0385" 4633 4618 4605 4605 4594 4584 4575 4567 4559 4561 4554 4548 4542 4536 4531
Concrete + Deck = 70.5 psf Icr = 116.8 in4/ft Mno/Ω= 61.6 kip-in/ft Vn/Ω = 5.28 kip/ft
(Icr+Iu)/2 = 213.93 in4/ft Iu = 311.1 in4/ft ϕMno= 94.3 kip-in/ft ϕ Vn = 7.58 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 669 587 517 459 409 366 329 296 268 243 220 200 183 167 152
LRFD, ϕW 1070 938 828 734 654 586 526 474 428 388 353 321 292 267 244
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 4995 4959 4927 4914 4887 4863 4841 4821 4803 4798 4782 4767 4753 4740 4728
PAF Base Steel ≥ .25" 4725 4704 4686 4686 4671 4657 4644 4633 4622 4625 4615 4607 4598 4591 4584
PAF Base Steel ≥ 0.125" 4704 4685 4668 4669 4654 4641 4629 4618 4608 4612 4603 4594 4587 4580 4573
#12 Screw Base Steel ≥ .0385" 4687 4669 4652 4654 4641 4628 4617 4606 4597 4601 4592 4584 4577 4570 4564
Concrete + Deck = 70.9 psf Icr = 133.9 in4/ft Mno/Ω= 72.5 kip-in/ft Vn/Ω = 5.70 kip/ft
(Icr+Iu)/2 = 226.56 in4/ft Iu = 319.2 in4/ft ϕMno= 110.9 kip-in/ft ϕ Vn = 8.55 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 871 765 677 602 538 483 435 394 357 325 296 271 248 228 209
LRFD, ϕW 1394 1225 1083 963 861 773 697 630 572 520 474 434 397 364 335
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5219 5169 5125 5114 5076 5043 5012 4984 4958 4956 4934 4913 4893 4875 4858
PAF Base Steel ≥ .25" 4848 4820 4795 4801 4780 4760 4742 4726 4711 4719 4705 4693 4681 4670 4660
PAF Base Steel ≥ 0.125" 4821 4795 4771 4779 4758 4739 4722 4707 4693 4702 4689 4677 4666 4656 4646
#12 Screw Base Steel ≥ .0385" 4803 4777 4754 4763 4743 4725 4709 4694 4680 4690 4677 4666 4655 4645 4636
Concrete + Deck = 71.6 psf Icr = 164.3 in4/ft Mno/Ω= 92.8 kip-in/ft Vn/Ω = 5.70 kip/ft
(Icr+Iu)/2 = 249.42 in /ft
4
Iu = 334.5 in4/ft ϕMno= 142.0 kip-in/ft ϕ Vn = 8.55 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1067 939 832 741 663 597 539 488 444 405 370 340 312 287 265
LRFD, ϕW 1708 1503 1331 1186 1062 955 862 781 711 648 593 543 499 459 424
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 5462 5396 5339 5332 5283 5239 5199 5162 5129 5132 5102 5074 5049 5025 5002
PAF Base Steel ≥ .25" 4984 4947 4914 4930 4901 4875 4851 4830 4810 4826 4808 4791 4776 4761 4748
PAF Base Steel ≥ 0.125" 4932 4898 4868 4886 4860 4836 4814 4794 4775 4793 4776 4761 4746 4733 4720
#12 Screw Base Steel ≥ .0385" 4944 4910 4880 4898 4872 4848 4826 4806 4788 4805 4788 4773 4758 4745 4732
Concrete + Deck = 72.4 psf Icr = 192.0 in4/ft Mno/Ω= 112.6 kip-in/ft Vn/Ω = 5.70 kip/ft
(Icr+Iu)/2 = 270.62 in4/ft Iu = 349.2 in4/ft ϕMno= 172.3 kip-in/ft ϕ Vn = 8.55 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. n/a 7020 8010 9810 12510
16 in o.c. n/a 7020 8010 9810 9890
24 in o.c. n/a 6590 6590 6590 6590

132 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NH-32 Composite Deck 5.3

GENERAL INFORMATION
8 1⁄4" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.982yd3/100ft2
3 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 7' - 7" 8' - 7" 8' - 10" 18 10' - 8" 11' - 9" 12' - 2"
20 8' - 9" 9' - 11" 10' - 2" 16 11' - 6" 13' - 4" 13' - 8"

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 655 574 505 447 398 355 318 286 258 233 211 191 174 158 144
LRFD, ϕW 1048 918 808 716 637 568 509 458 413 373 338 306 278 253 230
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 5624 5594 5568 5555 5534 5514 5496 5480 5465 5460 5447 5434 5423 5413 5403
PAF Base Steel ≥ .25" 5402 5385 5370 5369 5356 5345 5335 5325 5317 5318 5310 5303 5296 5290 5285
PAF Base Steel ≥ 0.125" 5385 5369 5355 5354 5342 5332 5322 5313 5305 5307 5299 5293 5287 5281 5275

2W PANELS
#12 Screw Base Steel ≥ .0385" 5369 5354 5341 5341 5330 5320 5311 5302 5295 5296 5290 5283 5277 5272 5267
Concrete + Deck = 79.6 psf Icr = 150.7 in4/ft Mno/Ω= 71.8 kip-in/ft Vn/Ω = 5.73 kip/ft
(Icr+Iu)/2 = 283.94 in4/ft Iu = 417.2 in4/ft ϕMno= 109.8 kip-in/ft ϕ Vn = 8.26 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 782 686 605 537 479 429 385 347 314 285 259 236 215 196 180
LRFD, ϕW 1251 1097 968 859 766 686 617 556 503 456 414 377 344 314 287
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 5731 5694 5662 5650 5623 5599 5577 5557 5538 5534 5517 5503 5489 5476 5464
PAF Base Steel ≥ .25" 5460 5440 5422 5422 5407 5393 5380 5368 5358 5360 5351 5342 5334 5327 5319
PAF Base Steel ≥ 0.125" 5440 5421 5404 5405 5390 5377 5365 5354 5344 5347 5338 5330 5322 5315 5308
#12 Screw Base Steel ≥ .0385" 5422 5404 5388 5390 5376 5364 5352 5342 5333 5336 5328 5320 5312 5306 5299
Concrete + Deck = 79.9 psf Icr = 173.1 in4/ft Mno/Ω= 84.5 kip-in/ft Vn/Ω = 6.61 kip/ft
(Icr+Iu)/2 = 300.31 in4/ft Iu = 427.5 in4/ft ϕMno= 129.3 kip-in/ft ϕ Vn = 9.91 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 1020 897 794 706 631 567 511 463 420 382 349 319 292 269 247
LRFD, ϕW 1633 1435 1270 1130 1010 907 818 740 672 612 558 510 468 430 395
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 5955 5905 5860 5849 5812 5778 5748 5719 5694 5692 5669 5648 5629 5611 5594
PAF Base Steel ≥ .25" 5584 5556 5531 5537 5515 5496 5478 5461 5446 5455 5441 5429 5417 5406 5396
PAF Base Steel ≥ 0.125" 5557 5530 5507 5514 5494 5475 5458 5443 5428 5437 5424 5413 5401 5391 5382
#12 Screw Base Steel ≥ .0385" 5538 5513 5490 5498 5479 5461 5444 5430 5416 5425 5413 5401 5391 5381 5372

C PANELS
Concrete + Deck = 80.7 psf Icr = 213.1 in4/ft Mno/Ω= 108.5 kip-in/ft Vn/Ω = 6.61 kip/ft
(Icr+Iu)/2 = 330.07 in /ft
4
Iu = 447.0 in4/ft ϕMno= 166.0 kip-in/ft ϕ Vn = 9.91 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 1252 1102 977 870 779 701 634 574 523 477 436 400 368 339 312
LRFD, ϕW 2004 1764 1563 1392 1247 1122 1014 919 836 763 698 640 588 542 500
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 6197 6132 6074 6068 6019 5975 5934 5898 5864 5868 5838 5810 5784 5760 5738
D PANEL

PAF Base Steel ≥ .25" 5720 5683 5650 5665 5637 5611 5587 5566 5546 5562 5544 5527 5511 5497 5483
PAF Base Steel ≥ 0.125" 5668 5634 5604 5622 5595 5571 5549 5529 5511 5529 5512 5496 5482 5468 5456
#12 Screw Base Steel ≥ .0385" 5680 5646 5616 5634 5607 5583 5562 5542 5523 5541 5524 5508 5494 5480 5468
Concrete + Deck = 81.5 psf Icr = 249.6 in4/ft Mno/Ω= 131.9 kip-in/ft Vn/Ω = 6.61 kip/ft
(Icr+Iu)/2 = 357.70 in4/ft Iu = 465.8 in4/ft ϕMno= 201.7 kip-in/ft ϕ Vn = 9.91 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. n/a 7760 8750 10550 13250
16 in o.c. n/a 7760 8750 9890 9890
24 in o.c. n/a 6590 6590 6590 6590
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 133
TABLE OF CONTENTS

5.3 NH-32 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 0.979yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 10' - 8" 11' - 9" 12' - 7" 18 13' - 7" 16' - 3" 16' - 3"
20 12' - 5" 13' - 9" 14' - 2" 16 14' - 4" 17' - 11" 17' - 0"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 269 236 208 184 164 146 131 118 107 96 87 79 72 66 60
LRFD, ϕW 430 377 332 294 262 234 210 189 171 154 140 127 115 105 96
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 1780 1751 1724 1712 1690 1671 1653 1636 1621 1616 1603 1591 1580 1569 1560
PAF Base Steel ≥ .25" 1558 1542 1527 1525 1513 1502 1491 1482 1473 1474 1467 1460 1453 1447 1441
PAF Base Steel ≥ 0.125" 1541 1526 1512 1511 1499 1488 1479 1470 1462 1463 1456 1449 1443 1437 1432
#12 Screw Base Steel ≥ .0385" 1525 1511 1498 1497 1486 1476 1467 1459 1451 1453 1446 1440 1434 1429 1424
Concrete + Deck = 31.0 psf Icr = 51.6 in4/ft Mno/Ω= 29.3 kip-in/ft Vn/Ω = 2.34 kip/ft
(Icr+Iu)/2 = 76.03 in4/ft Iu = 100.4 in4/ft ϕMno= 44.9 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 317 278 246 218 195 174 157 141 128 116 105 96 88 80 73
LRFD, ϕW 508 445 393 349 311 279 251 226 205 186 169 154 140 128 117
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 1889 1853 1821 1808 1782 1757 1735 1715 1697 1692 1676 1661 1647 1634 1622
PAF Base Steel ≥ .25" 1619 1599 1580 1581 1565 1551 1539 1527 1516 1519 1510 1501 1493 1485 1478
PAF Base Steel ≥ 0.125" 1598 1579 1562 1563 1549 1536 1524 1513 1503 1506 1497 1489 1481 1474 1467
#12 Screw Base Steel ≥ .0385" 1581 1563 1547 1549 1535 1522 1511 1501 1491 1495 1486 1478 1471 1464 1458
Concrete + Deck = 31.4 psf Icr = 58.5 in4/ft Mno/Ω= 34.2 kip-in/ft Vn/Ω = 2.34 kip/ft
(Icr+Iu)/2 = 81.52 in4/ft Iu = 104.5 in4/ft ϕMno= 52.3 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 406 357 316 281 251 225 203 184 163 144 128 115 103 93 84
LRFD, ϕW 649 571 505 449 402 361 325 294 267 243 222 203 186 171 157
L/360 - - - - - - - - 163 144 128 115 103 93 84
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2118 2068 2023 2012 1975 1941 1910 1882 1856 1855 1832 1811 1791 1773 1756
PAF Base Steel ≥ .25" 1747 1718 1693 1700 1678 1658 1640 1624 1609 1617 1604 1591 1580 1569 1559
PAF Base Steel ≥ 0.125" 1720 1693 1669 1677 1656 1638 1621 1605 1591 1600 1587 1575 1564 1554 1544
#12 Screw Base Steel ≥ .0385" 1701 1675 1653 1661 1641 1623 1607 1592 1579 1588 1576 1564 1553 1543 1534
Concrete + Deck = 32.2 psf Icr = 70.5 in4/ft Mno/Ω= 43.2 kip-in/ft Vn/Ω = 2.34 kip/ft
(Icr+Iu)/2 = 91.29 in /ft
4
Iu = 112.1 in4/ft ϕMno= 66.0 kip-in/ft ϕ Vn = 4.67 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 491 432 383 341 306 268 233 204 179 159 141 126 113 102 92
LRFD, ϕW 786 692 613 546 489 440 397 360 327 299 273 250 230 212 195
L/360 - - - - - 268 233 204 179 159 141 126 113 102 92
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2364 2299 2241 2234 2185 2141 2101 2064 2031 2034 2004 1977 1951 1927 1905
PAF Base Steel ≥ .25" 1886 1849 1816 1832 1803 1777 1754 1732 1712 1728 1710 1694 1678 1663 1650
PAF Base Steel ≥ 0.125" 1834 1800 1770 1788 1762 1738 1716 1696 1678 1695 1678 1663 1648 1635 1622
#12 Screw Base Steel ≥ .0385" 1843 1809 1778 1797 1770 1746 1724 1704 1686 1703 1687 1671 1656 1643 1630
Concrete + Deck = 32.9 psf Icr = 81.3 in4/ft Mno/Ω= 51.8 kip-in/ft Vn/Ω = 2.34 kip/ft
(Icr+Iu)/2 = 100.33 in4/ft Iu = 119.4 in4/ft ϕMno= 79.3 kip-in/ft ϕ Vn = 4.67 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. 2720 4070 5060 6860 9560
16 in o.c. 2720 4070 5060 6860 9560
24 in o.c. 2720 4070 5060 6590 6590
134 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

NH-32 Composite Deck 5.3

GENERAL INFORMATION
5 1⁄2" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.982yd3/100ft2
3 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 10' - 2" 11' - 4" 12' - 0" 18 13' - 2" 15' - 7" 15' - 9"
20 11' - 10" 13' - 2" 13' - 8" 16 13' - 11" 17' - 4" 16' - 6"

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 319 280 246 218 195 174 156 141 127 115 104 95 86 79 72
LRFD, ϕW 510 447 394 350 311 278 250 225 203 184 167 152 138 126 115
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2104 2075 2048 2036 2014 1995 1977 1960 1945 1940 1927 1915 1904 1893 1884
PAF Base Steel ≥ .25" 1882 1866 1851 1849 1837 1826 1815 1806 1798 1798 1791 1784 1777 1771 1765
PAF Base Steel ≥ 0.125" 1865 1850 1836 1835 1823 1812 1803 1794 1786 1787 1780 1773 1767 1762 1756

2W PANELS
#12 Screw Base Steel ≥ .0385" 1849 1835 1822 1821 1810 1800 1791 1783 1775 1777 1770 1764 1758 1753 1748
Concrete + Deck = 35.6 psf Icr = 67.3 in4/ft Mno/Ω= 34.7 kip-in/ft Vn/Ω = 2.68 kip/ft
(Icr+Iu)/2 = 99.79 in4/ft Iu = 132.2 in4/ft ϕMno= 53.1 kip-in/ft ϕ Vn = 5.31 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 376 330 292 259 231 207 186 168 152 138 126 115 105 96 88
LRFD, ϕW 602 529 467 415 370 332 298 269 244 221 201 184 168 153 140
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 2213 2177 2145 2132 2106 2081 2059 2039 2021 2016 2000 1985 1971 1958 1946
PAF Base Steel ≥ .25" 1943 1923 1904 1905 1889 1875 1863 1851 1841 1843 1834 1825 1817 1809 1802
PAF Base Steel ≥ 0.125" 1922 1903 1886 1887 1873 1860 1848 1837 1827 1830 1821 1813 1805 1798 1791
#12 Screw Base Steel ≥ .0385" 1905 1887 1871 1873 1859 1846 1835 1825 1815 1819 1810 1802 1795 1788 1782
Concrete + Deck = 36.0 psf Icr = 76.3 in4/ft Mno/Ω= 40.5 kip-in/ft Vn/Ω = 2.68 kip/ft
(Icr+Iu)/2 = 106.87 in4/ft Iu = 137.4 in4/ft ϕMno= 62.0 kip-in/ft ϕ Vn = 5.37 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 482 424 375 334 299 268 242 219 199 181 165 150 134 121 109
LRFD, ϕW 771 678 600 534 478 429 387 350 318 290 265 242 222 204 188
L/360 - - - - - - - - - - - 150 134 121 109
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2442 2392 2347 2336 2299 2265 2234 2206 2180 2179 2156 2135 2116 2097 2080
PAF Base Steel ≥ .25" 2071 2042 2017 2024 2002 1982 1964 1948 1933 1941 1928 1915 1904 1893 1883
PAF Base Steel ≥ 0.125" 2044 2017 1993 2001 1980 1962 1945 1929 1915 1924 1911 1899 1888 1878 1868
#12 Screw Base Steel ≥ .0385" 2025 1999 1977 1985 1965 1947 1931 1916 1903 1912 1900 1888 1877 1867 1858

C PANELS
Concrete + Deck = 36.8 psf Icr = 91.8 in4/ft Mno/Ω= 51.2 kip-in/ft Vn/Ω = 2.68 kip/ft
(Icr+Iu)/2 = 119.40 in /ft
4
Iu = 147.0 in4/ft ϕMno= 78.3 kip-in/ft ϕ Vn = 5.37 kip/ft
Vertical Load Span (in) 8'-0" 8'-6"
9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 583 514 455 406 363 327 295 266 234 207 184 164 147 133 120
LRFD, ϕW 933 822 728 649 581 523 472 428 390 356 326 299 274 253 233
L/360 - - - - - - - 266 234 207 184 164 147 133 120
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 2688 2623 2565 2558 2509 2465 2425 2388 2355 2358 2328 2301 2275 2251 2229
D PANEL

PAF Base Steel ≥ .25" 2210 2173 2140 2156 2127 2101 2078 2056 2036 2053 2034 2018 2002 1988 1974
PAF Base Steel ≥ 0.125" 2158 2124 2094 2112 2086 2062 2040 2020 2002 2019 2002 1987 1972 1959 1946
#12 Screw Base Steel ≥ .0385" 2167 2133 2102 2121 2094 2070 2048 2028 2010 2027 2011 1995 1981 1967 1954
Concrete + Deck = 37.5 psf Icr = 105.8 in4/ft Mno/Ω= 61.4 kip-in/ft Vn/Ω = 2.68 kip/ft
(Icr+Iu)/2 = 130.91 in4/ft Iu = 156.1 in4/ft ϕMno= 93.9 kip-in/ft ϕ Vn = 5.37 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. 3090 4440 5430 7230 9930
16 in o.c. 3090 4440 5430 7230 9890
24 in o.c. 3090 4440 5430 6590 6590

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 135


TABLE OF CONTENTS

5.3 NH-32 Composite Deck


6" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.288yd3/100ft2

Maximum Unshored Span (in)


Gage Single Double Triple Gage Single Double Triple
22 9' - 9" 10' - 11" 11' - 6" 18 12' - 9" 15' - 0" 15' - 3"
20 11' - 4" 12' - 8" 13' - 1" 16 13' - 7" 16' - 10" 16' - 1"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 373 327 288 256 228 204 183 165 149 135 122 111 101 92 84
LRFD, ϕW 596 523 461 409 364 326 293 264 238 216 196 178 162 148 135
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2428 2399 2372 2360 2338 2319 2301 2284 2270 2264 2251 2239 2228 2217 2208
PAF Base Steel ≥ .25" 2206 2190 2175 2173 2161 2150 2139 2130 2122 2122 2115 2108 2101 2095 2089
PAF Base Steel ≥ 0.125" 2189 2174 2160 2159 2147 2137 2127 2118 2110 2111 2104 2097 2091 2086 2080
#12 Screw Base Steel ≥ .0385" 2173 2159 2146 2145 2134 2124 2115 2107 2100 2101 2094 2088 2082 2077 2072
Concrete + Deck = 40.2 psf Icr = 85.9 in4/ft Mno/Ω= 40.4 kip-in/ft Vn/Ω = 3.05 kip/ft
(Icr+Iu)/2 = 128.25 in4/ft Iu = 170.6 in4/ft ϕMno= 61.9 kip-in/ft ϕ Vn = 5.59 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 440 386 341 303 271 243 219 197 179 162 148 135 123 113 103
LRFD, ϕW 704 618 546 485 433 388 350 316 286 260 236 216 197 181 166
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 2537 2501 2469 2456 2430 2405 2383 2363 2345 2340 2324 2309 2295 2282 2270
PAF Base Steel ≥ .25" 2267 2247 2229 2229 2213 2199 2187 2175 2165 2167 2158 2149 2141 2133 2126
PAF Base Steel ≥ 0.125" 2246 2227 2210 2211 2197 2184 2172 2161 2151 2154 2145 2137 2129 2122 2115
#12 Screw Base Steel ≥ .0385" 2229 2211 2195 2197 2183 2170 2159 2149 2139 2143 2134 2126 2119 2112 2106
Concrete + Deck = 40.6 psf Icr = 97.5 in4/ft Mno/Ω= 47.3 kip-in/ft Vn/Ω = 3.05 kip/ft
(Icr+Iu)/2 = 137.24 in4/ft Iu = 177.0 in4/ft ϕMno= 72.3 kip-in/ft ϕ Vn = 6.10 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 564 496 439 391 350 315 284 257 234 213 194 178 163 150 138
LRFD, ϕW 903 794 703 626 560 503 454 411 374 341 311 285 261 240 221
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2766 2716 2671 2660 2623 2589 2558 2530 2504 2503 2480 2459 2440 2421 2405
PAF Base Steel ≥ .25" 2395 2366 2341 2348 2326 2306 2288 2272 2257 2265 2252 2239 2228 2217 2207
PAF Base Steel ≥ 0.125" 2368 2341 2317 2325 2304 2286 2269 2253 2239 2248 2235 2223 2212 2202 2192
#12 Screw Base Steel ≥ .0385" 2349 2323 2301 2309 2289 2271 2255 2240 2227 2236 2224 2212 2201 2192 2182
Concrete + Deck = 41.3 psf Icr = 117.3 in4/ft Mno/Ω= 59.8 kip-in/ft Vn/Ω = 3.05 kip/ft
(Icr+Iu)/2 = 153.15 in4/ft Iu = 189.0 in4/ft ϕMno= 91.4 kip-in/ft ϕ Vn = 6.10 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 684 602 534 476 426 384 347 315 286 261 236 211 189 170 154
LRFD, ϕW 1094 963 854 761 682 614 555 503 458 418 383 351 323 298 275
L/360 - - - - - - - - - - 236 211 189 170 154
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3012 2947 2889 2882 2834 2789 2749 2712 2679 2682 2652 2625 2599 2575 2553
PAF Base Steel ≥ .25" 2534 2497 2464 2480 2451 2425 2402 2380 2360 2377 2358 2342 2326 2312 2298
PAF Base Steel ≥ 0.125" 2482 2448 2418 2436 2410 2386 2364 2344 2326 2343 2327 2311 2296 2283 2270
#12 Screw Base Steel ≥ .0385" 2491 2457 2427 2445 2418 2394 2372 2352 2334 2351 2335 2319 2305 2291 2278
Concrete + Deck = 42.1 psf Icr = 135.1 in4/ft Mno/Ω= 71.8 kip-in/ft Vn/Ω = 3.05 kip/ft
(Icr+Iu)/2 = 167.71 in4/ft Iu = 200.3 in4/ft ϕMno= 109.9 kip-in/ft ϕ Vn = 6.10 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. 3460 4810 5800 7600 10300
16 in o.c. 3460 4810 5800 7600 9890
24 in o.c. 3460 4810 5800 6590 6590

136 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

NH-32 Composite Deck 5.3

GENERAL INFORMATION
6 1⁄4" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.369yd3/100ft2
2 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 9' - 7" 10' - 9" 11' - 3" 18 12' - 7" 14' - 9" 15' - 1"
20 11' - 2" 12' - 6" 12' - 11" 16 13' - 4" 16' - 8" 15' - 10"

3W PANELS
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 401 351 310 275 245 219 197 177 160 145 132 120 109 100 91
LRFD, ϕW 641 562 496 440 392 351 315 284 257 233 211 192 175 160 146
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 2590 2561 2534 2522 2500 2481 2463 2447 2432 2426 2413 2401 2390 2380 2370
PAF Base Steel ≥ .25" 2369 2352 2337 2335 2323 2312 2301 2292 2284 2284 2277 2270 2263 2257 2251
PAF Base Steel ≥ 0.125" 2351 2336 2322 2321 2309 2299 2289 2280 2272 2273 2266 2259 2253 2248 2242

2W PANELS
#12 Screw Base Steel ≥ .0385" 2335 2321 2308 2307 2296 2286 2277 2269 2262 2263 2256 2250 2244 2239 2234
Concrete + Deck = 42.5 psf Icr = 96.3 in4/ft Mno/Ω= 43.4 kip-in/ft Vn/Ω = 3.24 kip/ft
(Icr+Iu)/2 = 144.38 in4/ft Iu = 192.4 in4/ft ϕMno= 66.4 kip-in/ft ϕ Vn = 5.73 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 473 416 367 326 291 261 235 213 193 175 159 145 133 122 112
LRFD, ϕW 758 665 588 522 466 418 376 340 308 280 255 233 213 195 179
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern

B PANELS
20
Arc Spot Weld 1/2" Effective Dia 2700 2663 2631 2618 2592 2567 2545 2525 2507 2502 2486 2471 2457 2445 2432
PAF Base Steel ≥ .25" 2429 2409 2391 2391 2375 2361 2349 2337 2327 2329 2320 2311 2303 2295 2288
PAF Base Steel ≥ 0.125" 2408 2389 2372 2373 2359 2346 2334 2323 2313 2316 2307 2299 2291 2284 2277
#12 Screw Base Steel ≥ .0385" 2391 2373 2357 2359 2345 2332 2321 2311 2301 2305 2296 2289 2281 2274 2268
Concrete + Deck = 42.9 psf Icr = 109.3 in4/ft Mno/Ω= 50.8 kip-in/ft Vn/Ω = 3.24 kip/ft
(Icr+Iu)/2 = 154.45 in4/ft Iu = 199.6 in4/ft ϕMno= 77.7 kip-in/ft ϕ Vn = 6.48 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)

N PANELS
ASD, W/Ω 607 534 473 421 377 339 306 277 252 229 210 192 176 162 149
LRFD, ϕW 972 855 757 674 603 542 489 443 403 367 336 307 282 259 239
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 2928 2878 2833 2822 2785 2751 2720 2692 2666 2665 2642 2621 2602 2583 2567
PAF Base Steel ≥ .25" 2557 2529 2503 2510 2488 2468 2450 2434 2419 2427 2414 2401 2390 2379 2369
PAF Base Steel ≥ 0.125" 2530 2503 2479 2487 2466 2448 2431 2415 2401 2410 2397 2385 2374 2364 2354
#12 Screw Base Steel ≥ .0385" 2511 2485 2463 2471 2451 2433 2417 2402 2389 2398 2386 2374 2363 2354 2344
Concrete + Deck = 43.6 psf Icr = 131.7 in4/ft Mno/Ω= 64.3 kip-in/ft Vn/Ω = 3.24 kip/ft

C PANELS
(Icr+Iu)/2 = 172.28 in4/ft Iu = 212.9 in4/ft ϕMno= 98.3 kip-in/ft ϕ Vn = 6.48 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 736 648 575 512 459 413 374 339 309 282 258 237 212 191 173
LRFD, ϕW 1178 1037 920 820 735 661 598 543 494 451 413 379 349 322 297
L/360 - - - - - - - - - - - 237 212 191 173
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3174 3109 3051 3044 2996 2951 2911 2875 2841 2844 2814 2787 2761 2737 2715
D PANEL

PAF Base Steel ≥ .25" 2696 2659 2626 2642 2613 2587 2564 2542 2522 2539 2520 2504 2488 2474 2460
PAF Base Steel ≥ 0.125" 2644 2610 2580 2598 2572 2548 2526 2506 2488 2505 2489 2473 2458 2445 2432
#12 Screw Base Steel ≥ .0385" 2653 2619 2589 2607 2580 2556 2534 2514 2496 2514 2497 2481 2467 2453 2440
Concrete + Deck = 44.4 psf Icr = 151.7 in4/ft Mno/Ω= 77.3 kip-in/ft Vn/Ω = 3.24 kip/ft
(Icr+Iu)/2 = 188.57 in4/ft Iu = 225.5 in4/ft ϕMno= 118.2 kip-in/ft ϕ Vn = 6.48 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


ACUSTADEK®

As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. n/a 4990 5980 7780 10480
16 in o.c. n/a 4990 5980 7780 9890
24 in o.c. n/a 4990 5980 6590 6590

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 137


TABLE OF CONTENTS

5.3 NH-32 Composite Deck


7 3⁄16" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.654yd3/100ft2
3 Hour Fire Rating
Maximum Unshored Span (in)
Gage Single Double Triple Gage Single Double Triple
22 9' - 0" 10' - 1" 10' - 6" 18 12' - 1" 13' - 10" 14' - 4"
20 10' - 5" 11' - 9" 12' - 1" 16 12' - 10" 15' - 8" 15' - 2"
GA Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 511 448 395 351 313 280 252 227 206 187 170 154 141 129 118
LRFD, ϕW 817 717 633 562 501 449 403 364 329 298 271 247 226 206 189
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
22 Arc Spot Weld 1/2" Effective Dia 3198 3168 3142 3130 3108 3088 3070 3054 3039 3034 3021 3009 2998 2987 2977
PAF Base Steel ≥ .25" 2976 2960 2945 2943 2931 2919 2909 2900 2891 2892 2884 2877 2871 2865 2859
PAF Base Steel ≥ 0.125" 2959 2943 2929 2928 2917 2906 2897 2888 2880 2881 2874 2867 2861 2855 2850
#12 Screw Base Steel ≥ .0385" 2943 2928 2915 2915 2904 2894 2885 2877 2869 2871 2864 2858 2852 2846 2841
Concrete + Deck = 51.1 psf Icr = 142.0 in4/ft Mno/Ω= 55.1 kip-in/ft Vn/Ω = 4.00 kip/ft
(Icr+Iu)/2 = 217.11 in4/ft Iu = 292.2 in4/ft ϕMno= 84.3 kip-in/ft ϕ Vn = 6.30 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 604 531 470 417 373 335 302 273 247 225 205 187 171 157 144
LRFD, ϕW 967 850 751 668 597 536 482 436 396 360 328 300 274 251 231
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
20
Arc Spot Weld 1/2" Effective Dia 3307 3271 3239 3226 3199 3175 3153 3133 3115 3110 3094 3079 3065 3052 3040
PAF Base Steel ≥ .25" 3037 3016 2998 2998 2983 2969 2956 2945 2934 2937 2927 2919 2910 2903 2896
PAF Base Steel ≥ 0.125" 3016 2997 2980 2981 2966 2953 2941 2930 2920 2924 2915 2906 2899 2892 2885
#12 Screw Base Steel ≥ .0385" 2999 2981 2964 2966 2953 2940 2929 2918 2909 2913 2904 2896 2889 2882 2876
Concrete + Deck = 51.5 psf Icr = 161.4 in4/ft Mno/Ω= 64.6 kip-in/ft Vn/Ω = 4.00 kip/ft
(Icr+Iu)/2 = 232 in4/ft Iu = 302.6 in4/ft ϕMno= 98.8 kip-in/ft ϕ Vn = 8.01 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 778 685 607 540 484 435 393 356 324 296 270 248 228 210 193
LRFD, ϕW 1245 1096 971 865 774 697 629 570 519 473 433 397 364 335 309
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
18
Arc Spot Weld 1/2" Effective Dia 3535 3485 3441 3430 3392 3359 3328 3300 3274 3272 3250 3229 3209 3191 3174
PAF Base Steel ≥ .25" 3164 3136 3111 3117 3096 3076 3058 3042 3027 3035 3021 3009 2997 2986 2976
PAF Base Steel ≥ 0.125" 3137 3111 3087 3094 3074 3055 3038 3023 3009 3018 3005 2993 2982 2971 2962
#12 Screw Base Steel ≥ .0385" 3119 3093 3070 3079 3059 3041 3025 3010 2996 3006 2993 2982 2971 2961 2952
Concrete + Deck = 52.2 psf Icr = 195.2 in4/ft Mno/Ω= 82.1 kip-in/ft Vn/Ω = 4.00 kip/ft
(Icr+Iu)/2 = 258.46 in /ft
4
Iu = 321.7 in4/ft ϕMno= 125.6 kip-in/ft ϕ Vn = 8.01 kip/ft
Vertical Load Span (in) 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"
ASD & LRFD - Superimposed Load, W (psf)
ASD, W/Ω 946 833 739 659 591 532 481 437 398 364 333 306 282 260 241
LRFD, ϕW 1513 1333 1182 1054 945 852 770 699 637 582 533 490 451 416 385
L/360 - - - - - - - - - - - - - - -
LRFD - Diaphragm Shear, ϕSn (plf / ft) 36/4 Attachment Pattern
16
Arc Spot Weld 1/2" Effective Dia 3782 3716 3659 3652 3603 3559 3519 3482 3448 3452 3422 3394 3369 3345 3322
PAF Base Steel ≥ .25" 3304 3267 3234 3250 3221 3195 3171 3150 3130 3146 3128 3111 3096 3081 3068
PAF Base Steel ≥ 0.125" 3252 3218 3188 3206 3179 3155 3134 3114 3095 3113 3096 3081 3066 3053 3040
#12 Screw Base Steel ≥ .0385" 3260 3226 3196 3214 3188 3164 3142 3122 3104 3121 3104 3089 3074 3061 3048
Concrete + Deck = 53.0 psf Icr = 225.3 in4/ft Mno/Ω= 98.9 kip-in/ft Vn/Ω = 4.00 kip/ft
(Icr+Iu)/2 = 282.61 in4/ft Iu = 339.9 in4/ft ϕMno= 151.3 kip-in/ft ϕ Vn = 8.01 kip/ft
LRFD - Diaphragm Shear, ϕSn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4 6x6 W2.9xW2.9 6x6 W4.0xW4.0 4x4 W4xW4 4x4 W6xW6
All Gages

3/4" Welded Shear Studs


As = 0.028 in2/ft As = 0.058 in2/ft As = 0.080 in2/ft As = 0.120 in2/ft As = 0.180 in2/ft
8 in o.c. n/a 5680 6670 8470 11170
16 in o.c. n/a 5680 6670 8470 9890
24 in o.c. n/a 5680 6590 6590 6590

138 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 139


TABLE OF CONTENTS

6.1 C0.9-32

7/8”

2-11/16”
32”

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
26 1.1 0.0195 80 82 0.299 0.028 0.44 0.062 0.306
24 1.4 0.0254 80 82 0.390 0.036 0.44 0.080 0.306
22 1.7 0.0314 80 82 0.482 0.045 0.46 0.098 0.305
20 2.0 0.0374 80 82 0.574 0.053 0.46 0.116 0.305

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
26 0.285 0.061 0.45 0.060 0.46 0.028 0.028 0.028 0.028
24 0.390 0.080 0.45 0.080 0.45 0.036 0.036 0.036 0.036
22 0.482 0.098 0.46 0.098 0.46 0.045 0.045 0.045 0.045
20 0.574 0.116 0.45 0.116 0.45 0.053 0.053 0.053 0.053

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 1.5" 2" 3" 1" 1.5" 2" 3"
End 377 431 460 460 577 660 703 703
26
Interior 473 532 562 562 724 814 860 860
End 699 795 844 844 1069 1216 1292 1292
24
Interior 950 1060 1117 1117 1453 1622 1710 1710
End 1117 1264 1341 1341 1710 1935 2052 2052
22
Interior 1585 1760 1850 1850 2425 2692 2831 2831
End 1627 1833 1940 1940 2489 2804 2968 2968
20
Interior 2370 2619 2749 2749 3626 4007 4206 4206
Web Crippling Constraints h=0.6" r=0.63" θ=48.8º

140 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

C0.9-32 6.2

GENERAL INFORMATION
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 2' - 0" 2' - 6" 3' - 0" 3' - 6" 4' - 0" 4' - 6" 5' - 0" 5' - 6" 6' - 0"
367 235 163 120 92 73 59 49 41

3W PANELS
fb / Ω
Φ fb 582 373 259 190 146 115 93 77 65
SS L/360 154 79 46 29 19 13 10 7 6
L/240 230 118 68 43 29 20 15 11 9
fb / Ω 357 228 158 116 89 70 57 47 40
566 362 251 185 141 112 91 75 63
26
Φ fb
DS L/360 - 189 110 69 46 32 24 18 14
L/240 - - - 104 69 49 36 27 21

2W PANELS
fb / Ω 446 285 198 146 111 88 71 59 50
Φ fb 707 453 314 231 177 140 113 94 79
TS L/360 339 174 100 63 42 30 22 16 13
L/240 - 260 151 95 64 45 33 24 19
fb / Ω 479 307 213 156 120 95 77 63 53
Φ fb 760 487 338 248 190 150 122 101 84
SS L/360 199 102 59 37 25 17 13 10 7
L/240 298 153 88 56 37 26 19 14 11

B PANELS
fb / Ω 479 307 213 156 120 95 77 63 53
760 487 338 248 190 150 122 101 84
24
Φ fb
DS L/360 479 245 142 89 60 42 31 23 18
L/240 - - 213 134 90 63 46 35 27
fb / Ω 599 383 266 196 150 118 96 79 67
Φ fb 950 608 422 310 238 188 152 126 106
TS L/360 439 225 130 82 55 39 28 21 16

N PANELS
L/240 - 337 195 123 82 58 42 32 24
fb / Ω 588 376 261 192 147 116 94 78 65
Φ fb 932 597 414 304 233 184 149 123 104
SS L/360 246 126 73 46 31 22 16 12 9
L/240 369 189 109 69 46 32 24 18 14
fb / Ω 588 376 261 192 147 116 94 78 65
932 597 414 304 233 184 149 123 104
22
Φ fb
DS - 303 175 110 74 52 38 28 22

C PANELS
L/360
L/240 - - - 166 111 78 57 43 33
fb / Ω 735 470 326 240 184 145 118 97 82
Φ fb 1165 746 518 381 291 230 186 154 129
TS L/360 543 278 161 101 68 48 35 26 20
L/240 - 417 241 152 102 71 52 39 30
fb / Ω 695 445 309 227 174 137 111 92 77
Φ fb 1102 705 490 360 275 218 176 146 122
SS
D PANEL

L/360 287 147 85 54 36 25 18 14 11


L/240 430 220 127 80 54 38 28 21 16
fb / Ω 695 445 309 227 174 137 111 92 77
1102 705 490 360 275 218 176 146 122
20
Φ fb
DS L/360 691 354 205 129 86 61 44 33 26
L/240 - - 307 193 130 91 66 50 38
fb / Ω 868 556 386 283 217 171 139 115 96
ACUSTADEK®

Φ fb 1377 882 612 450 344 272 220 182 153


TS L/360 633 324 188 118 79 56 41 30 23
L/240 - 486 281 177 119 83 61 46 35

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 141


TABLE OF CONTENTS

6.3 C0.9-32
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

C0.9-32 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
26 26.0 3' - 9" 4' - 4" 4' - 6"
24 26.3 4' - 7" 5' - 5" 5' - 6"
2.5 0.637
22 26.6 5' - 1" 6' - 3" 6' - 4"
20 26.9 5' - 4" 7' - 0" 6' - 7"
26 32.0 3' - 7" 4' - 2" 4' - 3"
24 32.3 4' - 4" 5' - 2" 5' - 2"
3 0.791
22 32.7 4' - 10" 5' - 11" 5' - 11"
20 33.0 5' - 0" 6' - 8" 6' - 3"
26 38.1 3' - 5" 4' - 0" 4' - 1"
24 38.4 4' - 2" 4' - 11" 5' - 0"
3.5 0.945
22 38.7 4' - 7" 5' - 8" 5' - 8"
20 39.0 4' - 9" 6' - 4" 5' - 11"
26 44.1 3' - 4" 3' - 10" 3' - 11"
24 44.4 4' - 0" 4' - 8" 4' - 9"
4 1.100
22 44.7 4' - 4" 5' - 5" 5' - 5"
20 45.1 4' - 7" 6' - 0" 5' - 8"
26 50.2 3' - 2" 3' - 8" 3' - 10"
24 50.5 3' - 10" 4' - 6" 4' - 7"
4.5 1.254
22 50.8 4' - 2" 5' - 2" 5' - 2"
20 51.1 4' - 5" 5' - 9" 5' - 5"
26 56.2 3' - 1" 3' - 7" 3' - 8"
24 56.5 3' - 9" 4' - 4" 4' - 5"
5 1.408
22 56.8 4' - 0" 5' - 0" 5' - 0"
20 57.1 4' - 3" 5' - 7" 5' - 3"
26 62.2 3' - 0" 3' - 6" 3' - 7"
24 62.6 3' - 7" 4' - 3" 4' - 3"
5.5 1.563
22 62.9 3' - 11" 4' - 10" 4' - 10"
20 63.2 4' - 1" 5' - 5" 5' - 1"
26 68.3 2' - 11" 3' - 4" 3' - 6"
24 68.6 3' - 6" 4' - 1" 4' - 2"
6 1.717
22 68.9 3' - 10" 4' - 8" 4' - 8"
20 69.2 4' - 0" 5' - 3" 4' - 11"
26 74.3 2' - 10" 3' - 3" 3' - 5"
24 74.6 3' - 5" 4' - 0" 4' - 1"
6.5 1.871
22 74.9 3' - 8" 4' - 7" 4' - 7"
20 75.3 3' - 11" 5' - 1" 4' - 10"

142 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

C0.9-32 6.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
C0.9-32 Shoring Table
110 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
26 20.0 4' - 0" 4' - 7" 4' - 9"

2W PANELS
24 20.3 4' - 10" 5' - 10" 5' - 10"
2.5 0.637
22 20.6 5' - 7" 6' - 9" 6' - 10"
20 20.9 5' - 10" 7' - 7" 7' - 3"
26 24.6 3' - 10" 4' - 5" 4' - 7"
24 24.9 4' - 8" 5' - 6" 5' - 7"
3 0.791
22 25.2 5' - 3" 6' - 5" 6' - 6"
20 25.5 5' - 6" 7' - 2" 6' - 10"

B PANELS
26 29.1 3' - 8" 4' - 3" 4' - 5"
24 29.5 4' - 6" 5' - 4" 5' - 4"
3.5 0.945
22 29.8 5' - 0" 6' - 1" 6' - 2"
20 30.1 5' - 3" 6' - 10" 6' - 6"
26 33.7 3' - 7" 4' - 1" 4' - 3"
24 34.0 4' - 4" 5' - 1" 5' - 2"
4 1.100
22 34.3 4' - 9" 5' - 11" 5' - 11"

N PANELS
20 34.7 5' - 0" 6' - 7" 6' - 2"
26 38.3 3' - 5" 4' - 0" 4' - 2"
24 38.6 4' - 2" 4' - 11" 5' - 0"
4.5 1.254
22 38.9 4' - 7" 5' - 8" 5' - 8"
20 39.2 4' - 10" 6' - 4" 5' - 11"
26 42.9 3' - 4" 3' - 10" 4' - 0"
24 43.2 4' - 1" 4' - 9" 4' - 10"
5 1.408

C PANELS
22 43.5 4' - 5" 5' - 6" 5' - 6"
20 43.8 4' - 8" 6' - 1" 5' - 9"
26 47.5 3' - 3" 3' - 9" 3' - 11"
24 47.8 3' - 11" 4' - 8" 4' - 8"
5.5 1.563
22 48.1 4' - 3" 5' - 4" 5' - 3"
20 48.4 4' - 6" 5' - 11" 5' - 7"
26 52.1 3' - 2" 3' - 8" 3' - 10"
D PANEL

24 52.4 3' - 10" 4' - 6" 4' - 7"


6 1.717
22 52.7 4' - 2" 5' - 2" 5' - 2"
20 53.0 4' - 4" 5' - 9" 5' - 5"
26 56.6 3' - 1" 3' - 6" 3' - 8"
24 57.0 3' - 8" 4' - 4" 4' - 5"
6.5 1.871
22 57.3 4' - 1" 5' - 0" 5' - 1"
20 57.6 4' - 3" 5' - 7" 5' - 8"
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 143


TABLE OF CONTENTS

6.4 C1.4-32

4-9/16”

1-3/8”

15/16”
32”

RD16 CP-32

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
26 1.1 0.0195 80 82 0.302 0.079 0.67 0.118 0.512
24 1.4 0.0254 80 82 0.393 0.103 0.67 0.153 0.511
22 1.7 0.0314 80 82 0.485 0.128 0.67 0.188 0.511
20 2.0 0.0374 80 82 0.576 0.150 0.68 0.222 0.510
18 2.6 0.0480 40 55 0.737 0.191 0.68 0.280 0.509

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
26 0.172 0.101 0.65 0.106 0.69 0.078 0.078 0.079 0.078
24 0.265 0.139 0.67 0.141 0.68 0.103 0.103 0.103 0.103
22 0.367 0.175 0.68 0.174 0.67 0.128 0.128 0.128 0.128
20 0.473 0.206 0.68 0.206 0.68 0.150 0.150 0.150 0.150
18 0.722 0.261 0.68 0.261 0.68 0.191 0.191 0.191 0.191

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 6" 1" 2" 4" 6"
End 315 399 517 522 482 610 791 798
26
Interior 559 686 865 873 855 1049 1324 1335
End 533 668 858 959 815 1021 1313 1467
24
Interior 936 1136 1419 1568 1432 1738 2171 2399
End 807 1003 1280 1439 1235 1535 1958 2201
22
Interior 1410 1696 2101 2333 2158 2595 3214 3569
End 1134 1399 1773 1988 1735 2140 2713 3042
20
Interior 1974 2357 2898 3209 3021 3606 4434 4909
End 1223 1493 1875 2094 1871 2284 2868 3204
18
Interior 2124 2508 3052 3364 3250 3838 4669 5147
Web Crippling Constraints h=1.82" r=0.125" θ=45º

144 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

C1.4-32 6.5

GENERAL INFORMATION
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)

3W PANELS
Limit Panel Span (Support Spacing)
Gage Span Condition 2' - 0" 2' - 6" 3' - 0" 3' - 6" 4' - 0" 4' - 6" 5' - 0" 5' - 6" 6' - 0"
fb / Ω 603 386 268 197 151 119 96 80 67
Φ fb 957 612 425 312 239 189 153 126 106
SS L/360 430 220 127 80 54 38 27 21 16
L/240 - 330 191 120 81 57 41 31 24
fb / Ω 637 408 283 208 159 126 102 84 71
26 DS Φ fb
L/360
L/240
1010
-
-
647
-
-
449
-
-
330
193
-
253
129
-
200
91
-
162
66
99
134
50
75
112
38
57

2W PANELS
fb / Ω 796 509 354 260 199 157 127 105 88
Φ fb 1263 808 561 412 316 249 202 167 140
TS L/360 - 485 281 177 118 83 61 46 35
L/240 - - - - 178 125 91 68 53
fb / Ω 832 533 370 272 208 164 133 110 92
Φ fb 1320 845 587 431 330 261 211 175 147
SS L/360 561 287 166 105 70 49 36 27 21
L/240 - 431 249 157 105 74 54 40 31
fb / Ω 843 540 375 275 211 167 135 111 94
24 DS Φ fb
L/360
1338
-
856
-
595
-
437
252
334
169
264
119
214
87
177
65
149
50

B PANELS
L/240 - - - - - - 130 98 75
fb / Ω 1054 675 468 344 263 208 169 139 117
Φ fb 1672 1070 743 546 418 330 268 221 186
TS L/360 - 634 367 231 155 109 79 60 46
L/240 - - - - 232 163 119 89 69
fb / Ω 1045 669 465 341 261 206 167 138 116
Φ fb 1658 1061 737 542 415 328 265 219 184
SS L/360 697 357 206 130 87 61 45 33 26
L/240 1045 535 310 195 131 92 67 50 39
fb / Ω 1043 668 464 341 261 206 167 138 116

N PANELS
22 DS Φ fb
L/360
L/240
1655
-
-
1059
-
-
736
-
-
540
313
-
414
210
-
327
147
-
265
107
161
219
81
121
184
62
93
fb / Ω 1304 835 580 426 326 258 209 172 145
Φ fb 2069 1324 920 676 517 409 331 274 230
TS L/360 - 787 455 287 192 135 98 74 57
L/240 - - - - 288 202 148 111 85
fb / Ω 1235 791 549 403 309 244 198 163 137
Φ fb 1960 1254 871 640 490 387 314 259 218
SS L/360 819 420 243 153 102 72 52 39 30
L/240 1229 629 364 229 154 108 79 59 46

C PANELS
fb / Ω 1235 791 549 403 309 244 198 163 137
20 DS Φ fb
L/360
L/240
1960
-
-
1254
-
-
871
-
-
640
368
-
490
247
-
387
173
-
314
126
189
259
95
142
218
73
110
fb / Ω 1544 988 686 504 386 305 247 204 172
Φ fb 2450 1568 1089 800 612 484 392 324 272
TS L/360 - 926 536 337 226 159 116 87 67
L/240 - - - - 339 238 174 130 100
fb / Ω 1043 668 464 341 261 206 167 138 116
Φ fb 1655 1059 736 541 414 327 265 219 184
SS
D PANEL

L/360 - 535 310 195 131 92 67 50 39


L/240 - - - 292 196 138 100 75 58
fb / Ω 1043 668 464 341 261 206 167 138 116
18 DS Φ fb
L/360
L/240
1655
-
-
1059
-
-
736
-
-
541
-
-
414
-
-
327
-
-
265
161
-
219
121
-
184
93
-
fb / Ω 1304 835 580 426 326 258 209 172 145
Φ fb 2069 1324 920 676 517 409 331 274 230
TS L/360 - - - - 288 202 148 111 85
L/240 - - - - - - - 166 128
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 145


TABLE OF CONTENTS

6.6 C1.4-32
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

C1.4-32 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
26 29.0 5' - 3" 6' - 5" 6' - 3"
24 29.3 6' - 6" 7' - 10" 7' - 10"
3 0.714 22 29.6 7' - 0" 8' - 11" 8' - 8"
20 29.9 7' - 4" 9' - 8" 9' - 1"
18 30.5 7' - 8" 8' - 10" 9' - 1"
26 35.1 5' - 0" 6' - 1" 6' - 0"
24 35.4 6' - 2" 7' - 5" 7' - 5"
3.5 0.868 22 35.7 6' - 7" 8' - 5" 8' - 2"
20 36.0 6' - 11" 9' - 2" 8' - 7"
18 36.5 7' - 3" 8' - 4" 8' - 6"
26 41.1 4' - 10" 5' - 10" 5' - 8"
24 41.4 5' - 10" 7' - 0" 7' - 1"
4 1.022 22 41.7 6' - 4" 8' - 0" 7' - 9"
20 42.0 6' - 8" 8' - 9" 8' - 2"
18 42.6 6' - 10" 8' - 0" 8' - 1"
26 47.1 4' - 7" 5' - 7" 5' - 6"
24 47.4 5' - 8" 6' - 9" 6' - 9"
4.5 1.177 22 47.8 6' - 0" 7' - 8" 7' - 5"
20 48.1 6' - 4" 8' - 4" 7' - 10"
18 48.6 6' - 7" 7' - 8" 7' - 9"
26 53.2 4' - 5" 5' - 5" 5' - 3"
24 53.5 5' - 5" 6' - 5" 6' - 6"
5 1.331 22 53.8 5' - 10" 7' - 4" 7' - 2"
20 54.1 6' - 2" 8' - 0" 7' - 7"
18 54.7 6' - 4" 7' - 4" 7' - 5"
26 59.2 4' - 3" 5' - 2" 5' - 1"
24 59.5 5' - 3" 6' - 3" 6' - 3"
5.5 1.485 22 59.8 5' - 7" 7' - 1" 6' - 11"
20 60.2 5' - 11" 7' - 8" 7' - 4"
18 60.7 6' - 1" 7' - 1" 7' - 2"
26 65.3 4' - 2" 5' - 0" 4' - 11"
24 65.6 5' - 1" 6' - 0" 6' - 0"
6 1.640 22 65.9 5' - 5" 6' - 10" 6' - 9"
20 66.2 5' - 9" 7' - 5" 7' - 1"
18 66.8 5' - 11" 6' - 10" 6' - 11"
26 71.3 4' - 0" 4' - 11" 4' - 9"
24 71.6 4' - 11" 5' - 10" 5' - 10"
6.5 1.794 22 71.9 5' - 4" 6' - 8" 6' - 7"
20 72.2 5' - 7" 7' - 2" 6' - 11"
18 72.8 5' - 8" 6' - 7" 6' - 8"

146 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

C1.4-32 6.6

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
C1.4-32 Shoring Table
110 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
26 22.3 5' - 8" 7' - 0" 6' - 10"
24 22.6 7' - 2" 8' - 6" 8' - 7"
3 0.714 22 22.9 7' - 8" 9' - 8" 9' - 5"

2W PANELS
20 23.2 8' - 1" 10' - 6" 9' - 11"
18 23.8 8' - 4" 9' - 7" 9' - 11"
26 26.9 5' - 5" 6' - 8" 6' - 6"
24 27.2 6' - 9" 8' - 1" 8' - 1"
3.5 0.868 22 27.5 7' - 3" 9' - 2" 8' - 11"
20 27.8 7' - 7" 10' - 0" 9' - 5"
18 28.3 7' - 11" 9' - 1" 9' - 4"

B PANELS
26 31.4 5' - 2" 6' - 4" 6' - 3"
24 31.7 6' - 5" 7' - 9" 7' - 9"
4 1.022 22 32.1 6' - 11" 8' - 9" 8' - 6"
20 32.4 7' - 3" 9' - 6" 9' - 0"
18 32.9 7' - 6" 8' - 9" 8' - 11"
26 36.0 5' - 0" 6' - 1" 6' - 0"
24 36.3 6' - 2" 7' - 5" 7' - 5"

N PANELS
4.5 1.177 22 36.6 6' - 7" 8' - 5" 8' - 2"
20 37.0 7' - 0" 9' - 2" 8' - 7"
18 37.5 7' - 3" 8' - 4" 8' - 6"
26 40.6 4' - 10" 5' - 11" 5' - 9"
24 40.9 5' - 11" 7' - 1" 7' - 2"
5 1.331 22 41.2 6' - 4" 8' - 1" 7' - 10"
20 41.5 6' - 8" 8' - 10" 8' - 3"

C PANELS
18 42.1 6' - 11" 8' - 1" 8' - 2"
26 45.2 4' - 8" 5' - 9" 5' - 7"
24 45.5 5' - 9" 6' - 10" 6' - 11"
5.5 1.485 22 45.8 6' - 2" 7' - 10" 7' - 7"
20 46.1 6' - 6" 8' - 6" 8' - 0"
18 46.7 6' - 8" 7' - 10" 7' - 11"
26 49.8 4' - 7" 5' - 6" 5' - 5"
D PANEL

24 50.1 5' - 7" 6' - 8" 6' - 8"


6 1.640 22 50.4 6' - 0" 7' - 7" 7' - 5"
20 50.7 6' - 4" 8' - 3" 7' - 9"
18 51.3 6' - 6" 7' - 7" 7' - 8"
26 54.4 4' - 5" 5' - 5" 5' - 3"
24 54.7 5' - 5" 6' - 5" 6' - 6"
6.5 1.794 22 55.0 5' - 10" 7' - 4" 7' - 2"
ACUSTADEK®

20 55.3 6' - 1" 8' - 0" 7' - 7"


18 55.8 6' - 4" 7' - 4" 7' - 5"

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 147


TABLE OF CONTENTS

7.1 4.5D-12

9”

4-1/2”

12”

2 Welds

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20 2.88 0.0359 33 45 0.848 2.763 2.62 1.056 1.805
18 3.84 0.0478 33 45 1.132 3.665 2.62 1.398 1.799
16 4.80 0.0598 33 45 1.432 4.605 2.62 1.755 1.793
14 6.09 0.075 33 45 1.785 5.691 2.63 2.166 1.786

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20 0.513 0.927 2.20 1.045 2.63 2.134 2.743 2.344 2.750
18 0.801 1.335 2.37 1.398 2.62 3.159 3.665 3.328 3.665
16 1.147 1.723 2.51 1.755 2.62 4.330 4.605 4.422 4.605
14 1.599 2.166 2.63 2.166 2.63 5.691 5.691 5.691 5.691

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 222 294 396 520 333 441 594 780
20
Interior 226 264 318 384 346 404 487 588
End 444 584 781 1060 666 876 1172 1590
18
Interior 444 513 611 749 680 786 935 1146
End 736 960 1278 1727 1104 1440 1917 2590
16
Interior 737 843 994 1206 1127 1290 1520 1846
End 1227 1590 2102 2827 1841 2384 3153 4240
14
Interior 1241 1407 1641 1972 1899 2153 2511 3017
Web Crippling Constraints h=4.2" r=0.125" θ=90º

148 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

4.5D-12 7.2

GENERAL INFORMATION
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
122 85 62 48 38 31 25 21 18 16 14

3W PANELS
fb / Ω
Φ fb 194 134 99 76 60 48 40 34 29 25 22
SS L/360 102 59 37 25 18 13 10 7 6 5 4
L/240 - - 56 38 26 19 14 11 9 7 6
fb / Ω 138 96 70 54
218 152 111 85
20
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
Maximum

2W PANELS
fb / Ω 172
Φ fb 273 Product Length
TS L/360 -
L/240 -
fb / Ω 176 122 90 69 54 44 36 31 26 22 20
Φ fb 279 194 142 109 86 70 58 48 41 36 31
SS L/360 145 84 53 36 25 18 14 11 8 7 5
L/240 - - 79 53 37 27 20 16 12 10 8

B PANELS
fb / Ω 184 128 94 72
292 203 149 114
18
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 230
Maximum
Φ fb 365 Product Length
TS L/360 -

N PANELS
L/240 -
fb / Ω 227 158 116 89 70 57 47 39 34 29 25
Φ fb 360 250 184 141 111 90 74 63 53 46 40
SS L/360 193 112 70 47 33 24 18 14 11 9 7
L/240 - - 106 71 50 36 27 21 16 13 11
fb / Ω 231 161 118 90
367 255 187 143
16
Φ fb
DS - - - -

C PANELS
L/360
Exceeds
L/240 - - - -
fb / Ω 289
Maximum
Φ fb 459 Product Length
TS L/360 -
L/240 -
fb / Ω 285 198 146 111 88 71 59 50 42 36 32
Φ fb 453 314 231 177 140 113 94 79 67 58 50
SS
D PANEL

L/360 249 144 91 61 43 31 23 18 14 11 9


L/240 - - 136 91 64 47 35 27 21 17 14
fb / Ω 285 198 146 111
453 314 231 177
14
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 357
Maximum
Product Length
ACUSTADEK®

Φ fb 566
TS L/360 -
L/240 -

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 149


TABLE OF CONTENTS

7.3 4.5D-12
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

4.5D-12 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20 34.6 14' - 6" 15' - 6" 10' - 8"
18 35.6 17' - 1" 16' - 0" 10' - 8"
6 0.810
16 36.5 18' - 3" 16' - 0" 10' - 8"
14 37.8 19' - 3" 16' - 0" 10' - 8"
20 40.6 13' - 8" 14' - 8" 10' - 8"
18 41.6 16' - 6" 16' - 0" 10' - 8"
6 1/2 0.965
16 42.6 17' - 7" 16' - 0" 10' - 8"
14 43.8 18' - 7" 16' - 0" 10' - 8"
20 46.7 12' - 11" 14' - 1" 10' - 8"
18 47.6 15' - 9" 16' - 0" 10' - 8"
7 1.119
16 48.6 17' - 1" 16' - 0" 10' - 8"
14 49.9 18' - 1" 16' - 0" 10' - 8"
20 52.7 12' - 4" 13' - 6" 10' - 8"
18 53.7 15' - 2" 15' - 6" 10' - 8"
7 1/2 1.273
16 54.6 16' - 7" 16' - 0" 10' - 8"
14 55.9 17' - 7" 16' - 0" 10' - 8"
20 58.8 11' - 10" 13' - 0" 10' - 8"
18 59.7 14' - 6" 14' - 11" 10' - 8"
8 1.427
16 60.7 16' - 2" 16' - 0" 10' - 8"
14 62.0 17' - 2" 16' - 0" 10' - 8"
20 64.8 11' - 5" 12' - 6" 10' - 8"
18 65.8 13' - 11" 14' - 5" 10' - 8"
8 1/2 1.582
16 66.7 15' - 10" 16' - 0" 10' - 8"
14 68.0 16' - 9" 16' - 0" 10' - 8"
20 70.8 11' - 0" 12' - 1" 10' - 8"
18 71.8 13' - 5" 13' - 11" 10' - 8"
9 1.736
16 72.8 15' - 5" 15' - 6" 10' - 8"
14 74.1 16' - 5" 16' - 0" 10' - 8"
20 76.9 10' - 8" 11' - 9" 10' - 8"
18 77.9 13' - 0" 13' - 6" 10' - 8"
9 1/2 1.890
16 78.8 14' - 11" 15' - 1" 10' - 8"
14 80.1 16' - 1" 16' - 0" 10' - 8"
20 82.9 10' - 4" 11' - 5" 10' - 8"
18 83.9 12' - 7" 13' - 2" 10' - 8"
10 2.045
16 84.9 14' - 5" 14' - 8" 10' - 8"
14 86.1 15' - 10" 16' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

150 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

4.5D-12 7.3

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
4.5D-12 Shoring Table
110 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20 26.9 15' - 7" 16' - 0" 10' - 8"
18 27.9 18' - 2" 16' - 0" 10' - 8"
6 0.810
16 28.9 19' - 5" 16' - 0" 10' - 8"
14 30.1 20' - 5" 16' - 0" 10' - 8"

2W PANELS
20 31.5 15' - 1" 16' - 0" 10' - 8"
18 32.5 17' - 7" 16' - 0" 10' - 8"
6 1/2 0.965
16 33.4 18' - 9" 16' - 0" 10' - 8"
14 34.7 19' - 9" 16' - 0" 10' - 8"
20 36.1 14' - 5" 15' - 5" 10' - 8"
18 37.1 17' - 0" 16' - 0" 10' - 8"
7 1.119
16 38.0 18' - 2" 16' - 0" 10' - 8"
14 39.3 19' - 2" 16' - 0" 10' - 8"

B PANELS
20 40.7 13' - 9" 14' - 10" 10' - 8"
18 41.7 16' - 7" 16' - 0" 10' - 8"
7 1/2 1.273
16 42.6 17' - 8" 16' - 0" 10' - 8"
14 43.9 18' - 8" 16' - 0" 10' - 8"
20 45.3 13' - 2" 14' - 4" 10' - 8"
18 46.2 16' - 1" 16' - 0" 10' - 8"
8 1.427
16 47.2 17' - 3" 16' - 0" 10' - 8"
14 48.5 18' - 3" 16' - 0" 10' - 8"

N PANELS
20 49.9 12' - 9" 13' - 10" 10' - 8"
18 50.8 15' - 6" 15' - 11" 10' - 8"
8 1/2 1.582
16 51.8 16' - 10" 16' - 0" 10' - 8"
14 53.1 17' - 10" 16' - 0" 10' - 8"
20 54.4 12' - 3" 13' - 5" 10' - 8"
18 55.4 15' - 1" 15' - 5" 10' - 8"
9 1.736
16 56.4 16' - 6" 16' - 0" 10' - 8"
14 57.6 17' - 6" 16' - 0" 10' - 8"
20 59.0 11' - 11" 13' - 0" 10' - 8"

C PANELS
18 60.0 14' - 7" 15' - 0" 10' - 8"
9 1/2 1.890
16 60.9 16' - 3" 16' - 0" 10' - 8"
14 62.2 17' - 2" 16' - 0" 10' - 8"
20 63.6 11' - 7" 12' - 8" 10' - 8"
18 64.6 14' - 2" 14' - 7" 10' - 8"
10 2.045
16 65.5 15' - 11" 16' - 0" 10' - 8"
14 66.8 16' - 11" 16' - 0" 10' - 8"
D PANEL

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 151


TABLE OF CONTENTS

7.4 4.5DF-24

4-1/2”

24”

RD31 4-1/2” Deep Deck Cellular

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 4.53 .0359/.036 33 45 1.193 4.727 1.85 2.559 1.991
20/18 5.02 .0359/.047 33 45 1.353 5.193 1.64 3.161 1.959
20/16 5.55 .0359/.059 33 45 1.514 5.564 1.48 3.753 1.917
18/20 5.49 .0478/.036 33 45 1.439 5.781 2.05 2.817 2.004
18/18 5.98 .0478/.047 33 45 1.599 6.369 1.86 3.424 1.996
18/16 6.51 .0478/.059 33 45 1.760 6.856 1.70 4.022 1.974
16/20 6.45 .0598/.036 33 45 1.685 6.753 2.20 3.070 2.002
16/18 6.94 .0598/.047 33 45 1.845 7.440 2.02 3.680 2.008
16/16 7.47 .0598/.059 33 45 2.005 8.024 1.87 4.282 2.000

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20/20 0.957 1.008 1.53 1.559 3.05 3.649 3.629 4.008 3.995
20/18 1.101 1.026 1.31 1.581 2.72 3.839 4.299 4.290 4.597
20/16 1.249 1.038 1.15 1.742 2.42 3.978 4.920 4.506 5.135
18/20 1.244 1.526 1.86 1.445 3.12 4.987 4.509 5.252 4.933
18/18 1.401 1.555 1.67 1.835 2.87 5.435 5.266 5.747 5.634
18/16 1.548 1.576 1.52 2.269 2.62 5.800 6.001 6.152 6.286
16/20 1.499 2.110 2.11 1.720 3.14 6.264 5.400 6.427 5.851
16/18 1.659 2.152 1.93 2.110 2.94 6.858 6.213 7.052 6.622
16/16 1.820 2.184 1.78 2.563 2.74 7.357 7.030 7.579 7.361

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Beam Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 222 294 396 520 333 441 594 780
20
Interior 226 264 318 384 346 404 487 588
End 444 584 781 1060 666 876 1172 1590
18
Interior 444 513 611 749 680 786 935 1146
End 736 960 1278 1727 1104 1440 1917 2590
16
Interior 737 843 994 1206 1127 1290 1520 1846
End 1227 1590 2102 2827 1841 2384 3153 4240
14
Interior 1241 1407 1641 1972 1899 2153 2511 3017
Web Crippling Constraints h=4.2" r=0.125" θ=90º

152 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

4.5DF-24 7.5

GENERAL INFORMATION
3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 133 92 68 52 41 33 27 23 20 17 15
Φ fb 211 146 108 82 65 53 44 37 31 27 23
SS L/360 - - 64 43 30 22 16 13 10 8 6
L/240 - - - - - 33 25 19 15 12 10

2W PANELS
fb / Ω 205 143 105 80 63 51
Φ fb 326 226 166 127 101 81
20/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 208
Maximum
Φ fb 329
Product Length
TS L/360 -

B PANELS
L/240 -
fb / Ω 135 94 69 53 42 34 28 23 20 17 15
Φ fb 214 149 109 84 66 54 44 37 32 27 24
SS L/360 - - 68 46 32 23 18 14 11 9 7
L/240 - - - - - - 26 20 16 13 10
fb / Ω 208 145 106 81 64 52
Φ fb 330 229 169 129 102 83
20/18 DS

N PANELS
L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 211
Maximum
Φ fb 335
Product Length
TS L/360 -
L/240 -
fb / Ω 137 95 70 53 42 34 28 24 20 17 15

C PANELS
Φ fb 217 151 111 85 67 54 45 38 32 28 24
SS L/360 - - - 48 34 25 18 14 11 9 7
L/240 - - - - - - 28 21 17 13 11
fb / Ω 229 159 117 90 71 57
Φ fb 364 253 186 142 112 91
20/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
Maximum
D PANEL

fb / Ω 214
Φ fb 339
Product Length
TS L/360 -
L/240 -
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 153


TABLE OF CONTENTS

7.5 4.5DF-24
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)


Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 201 140 103 79 62 50 42 35 30 26 22
Φ fb 319 221 163 125 98 80 66 55 47 41 35
SS L/360 - 133 84 56 39 29 22 17 13 10 9
L/240 - - - - 59 43 32 25 20 16 13
fb / Ω 190 132 97 74 59 48
Φ fb 302 210 154 118 93 75
18/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 238
Maximum
Φ fb 377
Product Length
TS L/360 -
L/240 -
fb / Ω 205 142 104 80 63 51 42 36 30 26 23
Φ fb 325 226 166 127 100 81 67 56 48 41 36
SS L/360 - - 92 61 43 31 24 18 14 11 9
L/240 - - - - - 47 35 27 21 17 14
fb / Ω 242 168 123 94 75 60
Φ fb 384 266 196 150 118 96
18/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 302
Maximum
Φ fb 479
Product Length
TS L/360 -
L/240 -
fb / Ω 208 144 106 81 64 52 43 36 31 26 23
Φ fb 329 229 168 129 102 82 68 57 49 42 37
SS L/360 - - 98 66 46 34 25 19 15 12 10
L/240 - - - - - 50 38 29 23 18 15
fb / Ω 299 208 152 117 92 75
Φ fb 474 329 242 185 146 119
18/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 324
Maximum
Φ fb 515
Product Length
TS L/360 -
L/240 -

154 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

4.5DF-24 7.5

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 278 193 142 109 86 69 57 48 41 35 31
Φ fb 441 306 225 172 136 110 91 77 65 56 49
SS L/360 - 163 102 69 48 35 26 20 16 13 10
L/240 - - - 103 72 53 40 30 24 19 16

2W PANELS
fb / Ω 227 157 116 89 70 57
Φ fb 360 250 183 140 111 90
16/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 283
Maximum
Φ fb 449
Product Length
TS L/360 -

B PANELS
L/240 -
fb / Ω 284 197 145 111 88 71 59 49 42 36 32
Φ fb 450 312 230 176 139 112 93 78 67 57 50
SS L/360 - 178 112 75 53 39 29 22 18 14 11
L/240 - - - - 79 58 43 33 26 21 17
fb / Ω 278 193 142 109 86 70
Φ fb 441 306 225 172 136 110
16/18 DS

N PANELS
L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 348
Maximum
Φ fb 551
Product Length
TS L/360 -
L/240 -
fb / Ω 288 200 147 112 89 72 59 50 43 37 32

C PANELS
Φ fb 456 317 233 178 141 114 94 79 68 58 51
SS L/360 - 192 121 81 57 41 31 24 19 15 12
L/240 - - - - 85 62 47 36 28 23 18
fb / Ω 338 234 172 132 104 84
Φ fb 536 372 273 209 165 134
16/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
Maximum
D PANEL

fb / Ω 422
Φ fb 669
Product Length
TS L/360 -
L/240 -
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 155


TABLE OF CONTENTS

7.6 4.5DF-24
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

4.5DF-24 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 36.6 14' - 11" 17' - 1" 10' - 8"
20/18 37.2 15' - 0" 17' - 1" 10' - 8"
20/16 37.8 15' - 0" 17' - 1" 10' - 8"
18/20 37.5 18' - 3" 17' - 9" 10' - 8"
6 0.821 18/18 38.1 18' - 4" 19' - 11" 10' - 8"
18/16 38.8 18' - 4" 20' - 0" 10' - 8"
16/20 38.5 19' - 9" 19' - 2" 10' - 8"
16/18 39.1 20' - 2" 20' - 0" 10' - 8"
16/16 39.7 20' - 5" 20' - 0" 10' - 8"
20/20 48.7 13' - 5" 15' - 6" 10' - 8"
20/18 49.2 13' - 6" 15' - 7" 10' - 8"
20/16 49.9 13' - 6" 15' - 8" 10' - 8"
18/20 49.6 16' - 8" 16' - 2" 10' - 8"
7 1.130 18/18 50.2 16' - 9" 18' - 2" 10' - 8"
18/16 50.8 16' - 9" 19' - 2" 10' - 8"
16/20 50.6 18' - 6" 17' - 7" 10' - 8"
16/18 51.2 18' - 11" 19' - 4" 10' - 8"
16/16 51.8 19' - 3" 20' - 0" 10' - 8"
20/20 60.7 12' - 3" 14' - 4" 10' - 8"
20/18 61.3 12' - 4" 14' - 5" 10' - 8"
20/16 62.0 12' - 5" 14' - 6" 10' - 8"
18/20 61.7 15' - 5" 15' - 0" 10' - 8"
8 1.438 18/18 62.3 15' - 6" 16' - 10" 10' - 8"
18/16 62.9 15' - 7" 17' - 9" 10' - 8"
16/20 62.7 17' - 7" 16' - 3" 10' - 8"
16/18 63.2 18' - 0" 17' - 11" 10' - 8"
16/16 63.9 18' - 2" 19' - 9" 10' - 8"
20/20 72.8 11' - 5" 13' - 5" 10' - 8"
20/18 73.4 11' - 6" 13' - 6" 10' - 8"
20/16 74.1 11' - 6" 13' - 7" 10' - 8"
18/20 73.8 14' - 4" 14' - 0" 10' - 8"
9 1.747 18/18 74.4 14' - 5" 15' - 9" 10' - 8"
18/16 75.0 14' - 6" 16' - 7" 10' - 8"
16/20 74.7 16' - 10" 15' - 3" 10' - 8"
16/18 75.3 17' - 0" 16' - 10" 10' - 8"
16/16 76.0 17' - 1" 18' - 6" 10' - 8"
20/20 84.9 10' - 8" 12' - 8" 10' - 8"
20/18 85.5 10' - 9" 12' - 9" 10' - 8"
20/16 86.1 10' - 10" 12' - 9" 10' - 8"
18/20 85.9 13' - 5" 13' - 3" 10' - 8"
10 2.056 18/18 86.5 13' - 7" 14' - 10" 10' - 8"
18/16 87.1 13' - 7" 15' - 8" 10' - 8"
16/20 86.8 15' - 11" 14' - 4" 10' - 8"
16/18 87.4 16' - 0" 15' - 10" 10' - 8"
16/16 88.1 16' - 1" 17' - 5" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

156 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

4.5DF-24 7.6

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
4.5DF-24 Shoring Table
110 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 28.8 16' - 2" 18' - 5" 10' - 8"
20/18 29.4 16' - 3" 18' - 6" 10' - 8"
20/16 30.0 16' - 3" 18' - 6" 10' - 8"
18/20 29.8 19' - 8" 19' - 2" 10' - 8"

2W PANELS
6 0.821 18/18 30.4 19' - 9" 20' - 0" 10' - 8"
18/16 31.0 19' - 10" 20' - 0" 10' - 8"
16/20 30.8 21' - 0" 20' - 0" 10' - 8"
16/18 31.3 21' - 4" 20' - 0" 10' - 8"
16/16 31.9 21' - 8" 20' - 0" 10' - 8"
20/20 38.0 14' - 10" 17' - 0" 10' - 8"
20/18 38.6 14' - 11" 17' - 1" 10' - 8"
20/16 39.2 14' - 11" 17' - 1" 10' - 8"

B PANELS
18/20 39.0 18' - 2" 17' - 8" 10' - 8"
7 1.130 18/18 39.5 18' - 3" 19' - 10" 10' - 8"
18/16 40.1 18' - 3" 20' - 0" 10' - 8"
16/20 39.9 19' - 9" 19' - 2" 10' - 8"
16/18 40.5 20' - 1" 20' - 0" 10' - 8"
16/16 41.1 20' - 5" 20' - 0" 10' - 8"
20/20 47.2 13' - 8" 15' - 10" 10' - 8"
20/18 47.7 13' - 9" 15' - 11" 10' - 8"

N PANELS
20/16 48.4 13' - 9" 15' - 11" 10' - 8"
18/20 48.1 16' - 11" 16' - 6" 10' - 8"
8 1.438 18/18 48.7 17' - 0" 18' - 6" 10' - 8"
18/16 49.3 17' - 1" 19' - 6" 10' - 8"
16/20 49.1 18' - 9" 17' - 10" 10' - 8"
16/18 49.7 19' - 2" 19' - 8" 10' - 8"
16/16 50.3 19' - 5" 20' - 0" 10' - 8"
20/20 56.3 12' - 9" 14' - 10" 10' - 8"

C PANELS
20/18 56.9 12' - 10" 14' - 11" 10' - 8"
20/16 57.5 12' - 10" 15' - 0" 10' - 8"
18/20 57.3 15' - 11" 15' - 6" 10' - 8"
9 1.747 18/18 57.9 16' - 0" 17' - 5" 10' - 8"
18/16 58.5 16' - 1" 18' - 4" 10' - 8"
16/20 58.3 18' - 0" 16' - 10" 10' - 8"
16/18 58.8 18' - 5" 18' - 7" 10' - 8"
16/16 59.4 18' - 8" 20' - 0" 10' - 8"
20/20 65.5 12' - 0" 14' - 1" 10' - 8"
D PANEL

20/18 66.1 12' - 1" 14' - 2" 10' - 8"


20/16 66.7 12' - 1" 14' - 2" 10' - 8"
18/20 66.5 15' - 1" 14' - 8" 10' - 8"
10 2.056 18/18 67.0 15' - 2" 16' - 6" 10' - 8"
18/16 67.6 15' - 3" 17' - 4" 10' - 8"
16/20 67.4 17' - 5" 15' - 11" 10' - 8"
16/18 68.0 17' - 9" 17' - 7" 10' - 8"
ACUSTADEK®

16/16 68.6 17' - 10" 19' - 4" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 157


TABLE OF CONTENTS

7.7 6D-12

9”

6”

12”
2 Welds

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20 3.25 0.0359 33 45 0.953 5.393 3.43 1.572 2.379
18 4.33 0.0478 33 45 1.273 7.165 3.44 2.085 2.372
16 5.41 0.0598 33 45 1.591 8.906 3.44 2.590 2.366
14 6.86 0.075 33 45 2.010 11.173 3.44 3.244 2.358

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20 0.516 1.369 2.93 1.453 3.55 4.211 5.154 4.605 5.234
18 0.810 1.981 3.12 2.085 3.44 6.180 7.165 6.508 7.165
16 1.143 2.529 3.28 2.590 3.44 8.304 8.906 8.505 8.906
14 1.638 3.242 3.44 3.244 3.44 11.144 11.173 11.154 11.173

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 194 256 414 453 290 385 620 680
20
Interior 197 230 314 335 301 352 480 512
End 400 525 839 954 600 788 1259 1431
18
Interior 400 462 617 674 612 707 944 1031
End 674 880 1394 1582 1011 1319 2091 2373
16
Interior 675 772 1016 1105 1033 1182 1554 1691
End 1141 1478 2319 2628 1711 2216 3479 3941
14
Interior 1154 1308 1692 1833 1766 2001 2589 2805
Web Crippling Constraints h=5.7" r=0.125" θ=90º

158 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

6D-12 7.8

GENERAL INFORMATION
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
180 125 92 70 56 45 37 31 27 23 20

3W PANELS
fb / Ω
Φ fb 286 199 146 112 88 72 59 50 42 37 32
SS L/360 - 116 73 49 35 25 19 15 11 9 7
L/240 - - - - 52 38 28 22 17 14 11
fb / Ω 191 133 98 75
304 211 155 119
20
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
Maximum

2W PANELS
fb / Ω 239
Φ fb 379 Product Length
TS L/360 -
L/240 -
fb / Ω 261 181 133 102 81 65 54 45 39 33 29
Φ fb 414 288 211 162 128 104 86 72 61 53 46
SS L/360 - 165 104 69 49 36 27 21 16 13 11
L/240 - - - - 73 53 40 31 24 19 16

B PANELS
fb / Ω 275 191 140 107
436 303 222 170
18
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 343
Maximum
Φ fb 545 Product Length
TS L/360 -

N PANELS
L/240 -
fb / Ω 333 231 170 130 103 83 69 58 49 42 37
Φ fb 529 367 270 206 163 132 109 92 78 67 59
SS L/360 - 215 135 91 64 46 35 27 21 17 14
L/240 - - - - 96 70 52 40 32 25 21
fb / Ω 341 237 174 133
541 376 276 211
16
Φ fb
DS - - - -

C PANELS
L/360
Exceeds
L/240 - - - -
fb / Ω 426
Maximum
Φ fb 677 Product Length
TS L/360 -
L/240 -
fb / Ω 427 297 218 167 132 107 88 74 63 54 47
Φ fb 677 470 346 265 209 169 140 118 100 86 75
SS
D PANEL

L/360 - 282 178 119 84 61 46 35 28 22 18


L/240 - - - - 125 91 69 53 42 33 27
fb / Ω 427 297 218 167
678 471 346 265
14
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 534
Maximum
Product Length
ACUSTADEK®

Φ fb 848
TS L/360 -
L/240 -

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 159


TABLE OF CONTENTS

7.9 6D-12
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

6D-12 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20 39.5 17' - 0" 16' - 0" 10' - 8"
18 40.6 19' - 7" 16' - 0" 10' - 8"
7 1/2 0.926
16 41.7 20' - 10" 16' - 0" 10' - 8"
14 43.1 22' - 1" 16' - 0" 10' - 8"
20 45.5 16' - 3" 16' - 0" 10' - 8"
18 46.6 18' - 11" 16' - 0" 10' - 8"
8 1.080
16 47.7 20' - 2" 16' - 0" 10' - 8"
14 49.2 21' - 5" 16' - 0" 10' - 8"
20 51.6 15' - 7" 16' - 0" 10' - 8"
18 52.7 18' - 5" 16' - 0" 10' - 8"
8 1/2 1.235
16 53.7 19' - 7" 16' - 0" 10' - 8"
14 55.2 20' - 10" 16' - 0" 10' - 8"
20 57.6 14' - 11" 15' - 5" 10' - 8"
18 58.7 17' - 10" 16' - 0" 10' - 8"
9 1.389
16 59.8 19' - 1" 16' - 0" 10' - 8"
14 61.2 20' - 4" 16' - 0" 10' - 8"
20 63.7 14' - 4" 14' - 10" 10' - 8"
18 64.7 17' - 3" 16' - 0" 10' - 8"
9 1/2 1.543
16 65.8 18' - 8" 16' - 0" 10' - 8"
14 67.3 19' - 11" 16' - 0" 10' - 8"
20 69.7 13' - 10" 14' - 4" 10' - 8"
18 70.8 16' - 8" 16' - 0" 10' - 8"
10 1.698
16 71.9 18' - 3" 16' - 0" 10' - 8"
14 73.3 19' - 6" 16' - 0" 10' - 8"
20 75.7 13' - 4" 13' - 11" 10' - 8"
18 76.8 16' - 2" 16' - 0" 10' - 8"
10 1/2 1.852
16 77.9 17' - 11" 16' - 0" 10' - 8"
14 79.4 19' - 1" 16' - 0" 10' - 8"
20 81.8 12' - 11" 13' - 6" 10' - 8"
18 82.9 15' - 8" 16' - 0" 10' - 8"
11 2.006
16 84.0 17' - 7" 16' - 0" 10' - 8"
14 85.4 18' - 9" 16' - 0" 10' - 8"
20 87.8 12' - 6" 13' - 2" 10' - 8"
18 88.9 15' - 3" 15' - 8" 10' - 8"
11 1/2 2.160
16 90.0 17' - 2" 16' - 0" 10' - 8"
14 91.4 18' - 6" 16' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

160 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

6D-12 7.9

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
6D-12 Shoring Table
110 pcf Normal Weight Concrete
Total Slab Depth Slab and Deck Volume Maximum Unshored Span
(in) Gage psf cy/100sf Single Double Triple
20 30.7 18' - 6" 16' - 0" 10' - 8"
18 31.8 20' - 10" 16' - 0" 10' - 8"
7 1/2 0.926
16 32.9 22' - 2" 16' - 0" 10' - 8"

2W PANELS
14 34.4 23' - 5" 16' - 0" 10' - 8"
20 35.3 17' - 9" 16' - 0" 10' - 8"
18 36.4 20' - 3" 16' - 0" 10' - 8"
8 1.080
16 37.5 21' - 6" 16' - 0" 10' - 8"
14 38.9 22' - 9" 16' - 0" 10' - 8"
20 39.9 17' - 1" 16' - 0" 10' - 8"
18 41.0 19' - 8" 16' - 0" 10' - 8"
8 1/2 1.235
16 42.1 20' - 11" 16' - 0" 10' - 8"
14 43.5 22' - 2" 16' - 0" 10' - 8"

B PANELS
20 44.5 16' - 6" 16' - 0" 10' - 8"
18 45.6 19' - 2" 16' - 0" 10' - 8"
9 1.389
16 46.7 20' - 4" 16' - 0" 10' - 8"
14 48.1 21' - 8" 16' - 0" 10' - 8"
20 49.1 15' - 11" 16' - 0" 10' - 8"
18 50.2 18' - 9" 16' - 0" 10' - 8"
9 1/2 1.543
16 51.2 19' - 11" 16' - 0" 10' - 8"
14 52.7 21' - 2" 16' - 0" 10' - 8"

N PANELS
20 53.7 15' - 5" 15' - 11" 10' - 8"
18 54.7 18' - 4" 16' - 0" 10' - 8"
10 1.698
16 55.8 19' - 6" 16' - 0" 10' - 8"
14 57.3 20' - 9" 16' - 0" 10' - 8"
20 58.2 15' - 0" 15' - 5" 10' - 8"
18 59.3 17' - 11" 16' - 0" 10' - 8"
10 1/2 1.852
16 60.4 19' - 2" 16' - 0" 10' - 8"
14 61.9 20' - 4" 16' - 0" 10' - 8"

C PANELS
20 62.8 14' - 6" 15' - 0" 10' - 8"
18 63.9 17' - 5" 16' - 0" 10' - 8"
11 2.006
16 65.0 18' - 10" 16' - 0" 10' - 8"
14 66.4 20' - 0" 16' - 0" 10' - 8"
20 67.4 14' - 1" 14' - 8" 10' - 8"
18 68.5 17' - 0" 16' - 0" 10' - 8"
11 1/2 2.160
16 69.6 18' - 6" 16' - 0" 10' - 8"
14 71.0 19' - 8" 16' - 0" 10' - 8"
D PANEL

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 161


TABLE OF CONTENTS

7.10 6DF-24

6”

24”

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 4.89 .0359/.036 33 45 1.298 8.747 2.49 0.788 2.596
20/18 5.38 .0359/.047 33 45 1.458 9.611 2.23 4.304 2.567
20/16 5.92 .0359/.059 33 45 1.619 10.308 2.03 5.090 2.523
18/20 5.98 .0478/.036 33 45 1.580 10.701 2.75 3.896 2.602
18/18 6.46 .0478/.047 33 45 1.740 11.772 2.51 4.696 2.601
18/16 7.00 .0478/.059 33 45 1.901 12.668 2.31 5.488 2.582
16/20 7.06 .0598/.036 33 45 1.862 12.517 2.93 4.278 2.593
16/18 7.55 .0598/.047 33 45 2.022 13.750 2.71 5.080 2.608
16/16 8.08 .0598/.059 33 45 2.182 14.809 0.58 1.249 2.605

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20/20 1.007 1.476 2.07 1.709 3.92 6.676 6.693 7.366 7.378
20/18 1.146 1.508 1.84 2.208 3.56 7.232 7.856 8.025 8.441
20/16 1.291 1.532 1.65 2.357 3.22 7.671 8.948 8.550 9.401
18/20 1.361 2.198 2.48 2.094 4.00 9.065 8.371 9.611 9.148
18/18 1.498 2.250 2.24 2.593 3.73 9.882 9.671 10.512 10.371
18/16 1.640 2.288 2.05 3.133 3.46 10.556 10.951 11.260 11.524
16/20 1.676 3.004 2.78 3.546 4.01 11.405 10.069 11.776 10.885
16/18 1.836 3.077 2.56 3.005 3.81 12.462 11.457 12.891 12.221
16/16 1.997 3.132 2.38 3.575 3.60 13.361 12.870 13.844 13.516

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Beam Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 194 256 414 453 290 385 620 680
20
Interior 197 230 314 335 301 352 480 512
End 400 525 839 954 600 788 1259 1431
18
Interior 400 462 617 674 612 707 944 1031
End 674 880 1394 1582 1011 1319 2091 2373
16
Interior 675 772 1016 1105 1033 1182 1554 1691
End 1141 1478 2319 2628 1711 2216 3479 3941
14
Interior 1154 1308 1692 1833 1766 2001 2589 2805
Web Crippling Constraints h=5.7" r=0.125" θ=90º
162 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

6DF-24 7.11

GENERAL INFORMATION
3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 194 135 99 76 60 49 40 34 29 25 22
Φ fb 309 214 157 121 95 77 64 54 46 39 34
SS L/360 - - - - 55 40 30 23 18 15 12

2W PANELS
L/240 - - - - - - - - 27 22 18
fb / Ω 225 156 115 88 70 56
Φ fb 357 248 182 140 110 89
20/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 281
Maximum
Φ fb 447
Product Length
TS

B PANELS
L/360 -
L/240 -
fb / Ω 199 138 101 78 61 50 41 34 29 25 22
Φ fb 315 219 161 123 97 79 65 55 47 40 35
SS L/360 - - - - 60 44 33 25 20 16 13
L/240 - - - - - - - - - 24 19
fb / Ω 291 202 148 114 90 73

N PANELS
Φ fb 462 320 235 180 142 115
20/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 310
Maximum
Φ fb 493
Product Length
TS L/360 -
L/240 -

C PANELS
fb / Ω 202 140 103 79 62 50 42 35 30 26 22
Φ fb 320 222 163 125 99 80 66 56 47 41 36
SS L/360 - - - - - 47 35 27 21 17 14
L/240 - - - - - - - - - 26 21
fb / Ω 310 216 158 121 96 78
Φ fb 493 342 251 192 152 123
20/16 DS L/360 - - - - - -
Exceeds
D PANEL

L/240 - - - - - -
fb / Ω 315
Maximum
Φ fb 500
Product Length
TS L/360 -
L/240 -
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 163


TABLE OF CONTENTS

7.11 6DF-24

Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)


Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 290 201 148 113 89 72 60 50 43 37 32
Φ fb 459 319 234 179 142 115 95 80 68 59 51
SS L/360 - - - 103 72 53 39 30 24 19 16
L/240 - - - - - - 59 46 36 29 23
fb / Ω 276 192 141 108 85 69
Φ fb 438 304 223 171 135 109
18/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 345
Maximum
Φ fb 547
Product Length
TS L/360 -
L/240 -
fb / Ω 296 206 151 116 91 74 61 51 44 38 33
Φ fb 470 327 240 184 145 118 97 82 70 60 52
SS L/360 - - - 112 79 57 43 33 26 21 17
L/240 - - - - - - - 50 39 31 26
fb / Ω 342 237 174 133 105 85
Φ fb 542 376 276 212 167 135
18/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 427
Maximum
Φ fb 677
Product Length
TS L/360 -
L/240 -
fb / Ω 301 209 154 118 93 75 62 52 45 38 33
Φ fb 478 332 244 187 148 120 99 83 71 61 53
SS L/360 - - - - 84 62 46 36 28 22 18
L/240 - - - - - - - - 42 34 27
fb / Ω 413 287 211 161 127 103
Φ fb 655 455 334 256 202 164
18/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 471
Maximum
Φ fb 747
Product Length
TS L/360 -
L/240 -

164 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

6DF-24 7.11

GENERAL INFORMATION
3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 396 275 202 155 122 99 82 69 59 50 44
Φ fb 628 436 320 245 194 157 130 109 93 80 70
SS L/360 - - 188 126 88 64 48 37 29 23 19

2W PANELS
L/240 - - - - - 96 72 56 44 35 29
fb / Ω 467 324 238 182 144 117
Φ fb 741 515 378 289 229 185
16/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 584
Maximum
Φ fb 926
Product Length
TS

B PANELS
L/360 -
L/240 -
fb / Ω 405 281 207 158 125 101 84 70 60 52 45
Φ fb 643 447 328 251 198 161 133 112 95 82 71
SS L/360 - - 205 138 97 70 53 41 32 26 21
L/240 - - - - - - 79 61 48 38 31
fb / Ω 396 275 202 155 122 99

N PANELS
Φ fb 628 436 320 245 194 157
16/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 495
Maximum
Φ fb 785
Product Length
TS L/360 -
L/240 -

C PANELS
fb / Ω 413 287 211 161 127 103 85 72 61 53 46
Φ fb 655 455 334 256 202 164 135 114 97 83 73
SS L/360 - - - 148 104 76 57 44 34 28 22
L/240 - - - - - - 85 66 52 41 34
fb / Ω 471 327 240 184 145 118
Φ fb 747 519 381 292 231 187
16/16 DS L/360 - - - - - -
Exceeds
D PANEL

L/240 - - - - - -
fb / Ω 589
Maximum
Φ fb 934
Product Length
TS L/360 -
L/240 -
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 165


TABLE OF CONTENTS

7.12 6DF-24
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

6DF-24 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 41.5 17' - 4" 18' - 8" 10' - 8"
20/18 42.1 17' - 6" 19' - 11" 10' - 8"
20/16 42.7 17' - 6" 20' - 0" 10' - 8"
18/20 42.6 21' - 0" 20' - 0" 10' - 8"
7 1/2 0.937 18/18 43.1 21' - 2" 20' - 0" 10' - 8"
18/16 43.8 21' - 3" 20' - 0" 10' - 8"
16/20 43.6 22' - 2" 20' - 0" 10' - 8"
16/18 44.2 22' - 7" 20' - 0" 10' - 8"
16/16 44.9 23' - 1" 20' - 0" 10' - 8"
20/20 53.6 15' - 11" 17' - 2" 10' - 8"
20/18 54.1 16' - 1" 18' - 4" 10' - 8"
20/16 54.8 16' - 1" 18' - 5" 10' - 8"
18/20 54.6 19' - 4" 18' - 10" 10' - 8"
8 1/2 1.246 18/18 55.2 19' - 6" 20' - 0" 10' - 8"
18/16 55.9 19' - 7" 20' - 0" 10' - 8"
16/20 55.7 20' - 11" 20' - 0" 10' - 8"
16/18 56.3 21' - 4" 20' - 0" 10' - 8"
16/16 57.0 21' - 10" 20' - 0" 10' - 8"
20/20 65.6 14' - 9" 15' - 11" 10' - 8"
20/18 66.2 14' - 11" 17' - 0" 10' - 8"
20/16 66.9 15' - 0" 17' - 1" 10' - 8"
18/20 66.7 18' - 0" 17' - 6" 10' - 8"
9 1/2 1.554 18/18 67.3 18' - 1" 19' - 5" 10' - 8"
18/16 68.0 18' - 2" 20' - 0" 10' - 8"
16/20 67.8 19' - 11" 20' - 0" 10' - 8"
16/18 68.4 20' - 4" 20' - 0" 10' - 8"
16/16 69.0 20' - 10" 20' - 0" 10' - 8"
20/20 77.7 13' - 9" 14' - 11" 10' - 8"
20/18 78.3 13' - 11" 16' - 0" 10' - 8"
20/16 79.0 14' - 0" 16' - 1" 10' - 8"
18/20 78.8 16' - 10" 16' - 6" 10' - 8"
10 1/2 1.863 18/18 79.4 17' - 0" 18' - 3" 10' - 8"
18/16 80.0 17' - 1" 19' - 6" 10' - 8"
16/20 79.9 19' - 2" 20' - 0" 10' - 8"
16/18 80.5 19' - 7" 19' - 7" 10' - 8"
16/16 81.1 19' - 11" 20' - 0" 10' - 8"
20/20 89.8 12' - 11" 14' - 2" 10' - 8"
20/18 90.4 13' - 1" 15' - 1" 10' - 8"
20/16 91.0 13' - 2" 15' - 2" 10' - 8"
18/20 90.9 15' - 11" 15' - 7" 10' - 8"
11 1/2 2.171 18/18 91.5 16' - 1" 17' - 3" 10' - 8"
18/16 92.1 16' - 2" 18' - 6" 10' - 8"
16/20 92.0 18' - 7" 20' - 0" 10' - 8"
16/18 92.6 18' - 9" 18' - 6" 10' - 8"
16/16 93.2 18' - 10" 20' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
166 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

6DF-24 7.12

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
6DF-24 Shoring Table
110 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 32.6 18' - 10" 20' - 0" 10' - 8"
20/18 33.2 19' - 0" 20' - 0" 10' - 8"
20/16 33.8 19' - 0" 20' - 0" 10' - 8"

2W PANELS
18/20 33.7 22' - 4" 20' - 0" 10' - 8"
7 1/2 0.937 18/18 34.3 22' - 9" 20' - 0" 10' - 8"
18/16 34.9 23' - 0" 20' - 0" 10' - 8"
16/20 34.8 23' - 6" 20' - 0" 10' - 8"
16/18 35.4 23' - 11" 20' - 0" 10' - 8"
16/16 36.0 24' - 6" 20' - 0" 10' - 8"
20/20 41.8 17' - 5" 18' - 9" 10' - 8"
20/18 42.4 17' - 7" 20' - 0" 10' - 8"

B PANELS
20/16 43.0 17' - 7" 20' - 0" 10' - 8"
18/20 42.9 21' - 1" 20' - 0" 10' - 8"
8 1/2 1.246 18/18 43.5 21' - 3" 20' - 0" 10' - 8"
18/16 44.1 21' - 4" 20' - 0" 10' - 8"
16/20 44.0 22' - 3" 20' - 0" 10' - 8"
16/18 44.5 22' - 8" 20' - 0" 10' - 8"
16/16 45.2 23' - 2" 20' - 0" 10' - 8"
20/20 51.0 16' - 4" 17' - 7" 10' - 8"

N PANELS
20/18 51.5 16' - 5" 18' - 9" 10' - 8"
20/16 52.2 16' - 6" 18' - 10" 10' - 8"
18/20 52.1 19' - 9" 19' - 4" 10' - 8"
9 1/2 1.554 18/18 52.6 19' - 11" 20' - 0" 10' - 8"
18/16 53.2 20' - 0" 20' - 0" 10' - 8"
16/20 53.1 21' - 3" 20' - 0" 10' - 8"
16/18 53.7 21' - 8" 20' - 0" 10' - 8"
16/16 54.3 22' - 2" 20' - 0" 10' - 8"
20/20 60.1 15' - 5" 16' - 7" 10' - 8"

C PANELS
20/18 60.7 15' - 6" 17' - 8" 10' - 8"
20/16 61.3 15' - 7" 17' - 9" 10' - 8"
18/20 61.2 18' - 8" 18' - 2" 10' - 8"
10 1/2 1.863 18/18 61.8 18' - 10" 20' - 0" 10' - 8"
18/16 62.4 18' - 11" 20' - 0" 10' - 8"
16/20 62.3 20' - 5" 20' - 0" 10' - 8"
16/18 62.9 20' - 10" 20' - 0" 10' - 8"
16/16 63.5 21' - 4" 20' - 0" 10' - 8"
D PANEL

20/20 69.3 14' - 7" 15' - 8" 10' - 8"


20/18 69.9 14' - 8" 16' - 9" 10' - 8"
20/16 70.5 14' - 9" 16' - 10" 10' - 8"
18/20 70.4 17' - 8" 17' - 3" 10' - 8"
11 1/2 2.171 18/18 71.0 17' - 10" 19' - 2" 10' - 8"
18/16 71.6 17' - 11" 20' - 0" 10' - 8"
16/20 71.5 19' - 9" 20' - 0" 10' - 8"
ACUSTADEK®

16/18 72.0 20' - 2" 20' - 0" 10' - 8"


16/16 72.7 20' - 8" 20' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 167
TABLE OF CONTENTS

7.13 7.5D-12

9”

7-1/2”

12”
2 Welds

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20 3.60 0.0359 33 45 1.058 9.088 4.23 2.148 2.931
18 4.80 0.0478 33 45 1.414 12.089 4.24 2.853 2.924
16 6.00 0.0598 33 45 1.768 15.040 4.24 3.547 2.917
14 7.60 0.075 33 45 2.235 18.900 4.25 4.451 2.908

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20 0.519 1.718 3.50 1.791 4.60 6.863 8.231 7.605 8.517
18 0.816 2.702 3.87 2.548 4.47 10.457 11.389 11.001 11.622
16 1.154 3.454 4.05 3.316 4.38 14.003 14.524 14.349 14.696
14 1.661 4.440 4.23 4.360 4.29 18.778 18.700 18.819 18.767

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Beam Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 169 223 360 395 253 335 540 592
20
Interior 171 200 273 292 262 307 418 446
End 361 474 757 861 541 711 1136 1291
18
Interior 361 417 557 608 552 638 852 931
End 620 809 1282 1455 930 1213 1923 2182
16
Interior 621 710 934 1016 950 1087 1430 1555
End 1065 1380 2166 2453 1598 2069 3248 3680
14
Interior 1077 1221 1580 1711 1648 1868 2417 2619
Web Crippling Constraints h=7.2" r=0.125" θ=90º

168 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

7.5D-12 7.14

GENERAL INFORMATION
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
226 157 115 88 70 57 47 39 33 29 25

3W PANELS
fb / Ω
Φ fb 359 249 183 140 111 90 74 62 53 46 40
SS L/360 - - - 81 57 42 31 24 19 15 12
L/240 - - - - - - - 36 28 23 18
fb / Ω 236 164 120 92
374 260 191 146
20
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
Maximum

2W PANELS
fb / Ω 295
Φ fb 468 Product Length
TS L/360 -
L/240 -
fb / Ω 356 247 182 139 110 89 74 62 53 45 40
Φ fb 565 392 288 221 174 141 117 98 84 72 63
SS L/360 - - 175 117 82 60 45 35 27 22 18
L/240 - - - - - - 68 52 41 33 27

B PANELS
fb / Ω 336 233 171 131
532 370 272 208
18
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 420
Maximum
Φ fb 666 Product Length
TS L/360 -

N PANELS
L/240 -
fb / Ω 455 316 232 178 140 114 94 79 67 58 51
Φ fb 722 501 368 282 223 180 149 125 107 92 80
SS L/360 - - 229 153 108 78 59 45 36 29 23
L/240 - - - - - - 88 68 54 43 35
fb / Ω 437 303 223 171
693 481 354 271
16
Φ fb
DS - - - -

C PANELS
L/360
Exceeds
L/240 - - - -
fb / Ω 546
Maximum
Φ fb 866 Product Length
TS L/360 -
L/240 -
fb / Ω 585 406 298 228 181 146 121 102 87 75 65
Φ fb 928 644 473 362 286 232 192 161 137 118 103
SS
D PANEL

L/360 - - - 201 141 103 77 59 47 37 30


L/240 - - - - - - 116 89 70 56 46
fb / Ω 574 399 293 224
911 633 465 356
14
Φ fb
DS L/360 - - - -
Exceeds
L/240 - - - -
fb / Ω 718
Maximum
Product Length
ACUSTADEK®

Φ fb 1139
TS L/360 -
L/240 -

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 169


TABLE OF CONTENTS

7.15 7.5D-12
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

7.5D-12 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20 44.4 18' - 4" 16' - 0" 10' - 8"
18 45.6 21' - 9" 16' - 0" 10' - 8"
9 1.042
16 46.8 23' - 1" 16' - 0" 10' - 8"
14 48.4 24' - 6" 16' - 0" 10' - 8"
20 50.4 17' - 7" 16' - 0" 10' - 8"
18 51.6 21' - 1" 16' - 0" 10' - 8"
9 1/2 1.196
16 52.8 22' - 5" 16' - 0" 10' - 8"
14 54.4 23' - 10" 16' - 0" 10' - 8"
20 56.5 16' - 11" 16' - 0" 10' - 8"
18 57.7 20' - 7" 16' - 0" 10' - 8"
10 1.350
16 58.9 21' - 10" 16' - 0" 10' - 8"
14 60.5 23' - 3" 16' - 0" 10' - 8"
20 62.5 16' - 3" 16' - 0" 10' - 8"
18 63.7 20' - 1" 16' - 0" 10' - 8"
10 1/2 1.505
16 64.9 21' - 4" 16' - 0" 10' - 8"
14 66.5 22' - 9" 16' - 0" 10' - 8"
20 68.5 15' - 9" 16' - 0" 10' - 8"
18 69.7 19' - 7" 16' - 0" 10' - 8"
11 1.659
16 70.9 20' - 11" 16' - 0" 10' - 8"
14 72.5 22' - 3" 16' - 0" 10' - 8"
20 74.6 15' - 3" 15' - 7" 10' - 8"
18 75.8 19' - 0" 16' - 0" 10' - 8"
11 1/2 1.813
16 77.0 20' - 6" 16' - 0" 10' - 8"
14 78.6 21' - 10" 16' - 0" 10' - 8"
20 80.6 14' - 9" 15' - 1" 10' - 8"
18 81.8 18' - 5" 16' - 0" 10' - 8"
12 1.968
16 83.0 20' - 2" 16' - 0" 10' - 8"
14 84.6 21' - 5" 16' - 0" 10' - 8"
20 86.7 14' - 4" 14' - 8" 10' - 8"
18 87.9 17' - 11" 16' - 0" 10' - 8"
12 1/2 2.122
16 89.1 19' - 10" 16' - 0" 10' - 8"
14 90.7 21' - 1" 16' - 0" 10' - 8"
20 92.7 13' - 11" 14' - 3" 10' - 8"
18 93.9 17' - 5" 16' - 0" 10' - 8"
13 2.276
16 95.1 19' - 6" 16' - 0" 10' - 8"
14 96.7 20' - 9" 16' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

170 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

7.5D-12 7.15

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
4.5D-12 Shoring Table
145 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20 34.5 20' - 0" 16' - 0" 10' - 8"
18 35.7 23' - 2" 16' - 0" 10' - 8"
9 1.042
16 36.9 24' - 7" 16' - 0" 10' - 8"

2W PANELS
14 38.5 26' - 0" 16' - 0" 10' - 8"
20 39.1 19' - 3" 16' - 0" 10' - 8"
18 40.3 22' - 6" 16' - 0" 10' - 8"
9 1/2 1.196
16 41.5 23' - 10" 16' - 0" 10' - 8"
14 43.1 25' - 4" 16' - 0" 10' - 8"
20 43.7 18' - 7" 16' - 0" 10' - 8"
18 44.9 21' - 11" 16' - 0" 10' - 8"
10 1.350
16 46.1 23' - 3" 16' - 0" 10' - 8"
14 47.7 24' - 9" 16' - 0" 10' - 8"

B PANELS
20 48.3 17' - 11" 16' - 0" 10' - 8"
18 49.5 21' - 5" 16' - 0" 10' - 8"
10 1/2 1.505
16 50.7 22' - 9" 16' - 0" 10' - 8"
14 52.3 24' - 2" 16' - 0" 10' - 8"
20 52.9 17' - 5" 16' - 0" 10' - 8"
18 54.1 21' - 0" 16' - 0" 10' - 8"
11 1.659
16 55.3 22' - 3" 16' - 0" 10' - 8"
14 56.9 23' - 8" 16' - 0" 10' - 8"

N PANELS
20 57.5 16' - 11" 16' - 0" 10' - 8"
18 58.7 20' - 7" 16' - 0" 10' - 8"
11 1/2 1.813
16 59.9 21' - 10" 16' - 0" 10' - 8"
14 61.5 23' - 3" 16' - 0" 10' - 8"
20 62.0 16' - 5" 16' - 0" 10' - 8"
18 63.2 20' - 2" 16' - 0" 10' - 8"
12 1.968
16 64.4 21' - 6" 16' - 0" 10' - 8"
14 66.0 22' - 10" 16' - 0" 10' - 8"

C PANELS
20 66.6 16' - 0" 16' - 0" 10' - 8"
18 67.8 19' - 10" 16' - 0" 10' - 8"
12 1/2 2.122
16 69.0 21' - 1" 16' - 0" 10' - 8"
14 70.6 22' - 6" 16' - 0" 10' - 8"
20 71.2 15' - 7" 15' - 11" 10' - 8"
18 72.4 19' - 5" 16' - 0" 10' - 8"
13 2.276
16 73.6 20' - 10" 16' - 0" 10' - 8"
14 75.2 22' - 2" 16' - 0" 10' - 8"
D PANEL

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 171


TABLE OF CONTENTS

7.16 7.5DF-24

7-1/2”

24”

RD33 7-1/2” Deep Deck Cellular

Panel Properties
Gross Section Properties
Distance to
Base Metal Tensile Moment of N.A. from Section Radius of
Gage Weight Thickness Yield Strength Strength Area Inertia Bottom Modulus Gyration
w t Fy Fu Ag Ig yb Sg r
psf in ksi ksi in2/ft in4/ft in in3/ft in
20/20 5.24 .0359/.036 33 45 1.403 14.204 3.16 4.502 3.182
20/18 5.73 .0359/.047 33 45 1.563 15.605 2.84 5.486 3.159
20/16 6.27 .0359/.059 33 45 1.724 16.751 2.59 6.460 3.117
18/20 6.44 .0478/.036 33 45 1.721 17.391 3.45 5.040 3.179
18/18 6.93 .0478/.047 33 45 1.881 19.100 3.17 6.027 3.186
18/16 7.47 .0478/.059 33 45 2.042 20.549 2.93 7.007 3.172
16/20 7.64 .0598/.036 33 45 2.039 20.374 3.66 5.573 3.660
16/18 8.13 .0598/.047 33 45 2.199 22.320 3.40 6.562 3.186
16/16 8.67 .0598/.059 33 45 2.359 24.010 3.18 7.544 3.190

Effective Section Modulus at Fy


Effective Moment of Inertia for Deflection
Compression Bending

Distance to Distance to Uniform Load Only


Section N.A. from Section N.A. from Moment of Moment of
Gage Area Inertia Inertia Id = (2Ie+Ig)/3
Modulus Bottom Modulus Bottom
Ae Se+ yb Se- yb Ie+ I e- I+ I-
in2/ft in3/ft in in3/ft in in4/ft in4/ft in4/ft in4/ft
20/20 1.056 1.821 2.61 2.252 4.84 10.687 10.905 11.859 12.005
20/18 1.191 2.048 2.40 2.890 4.40 11.874 12.701 13.117 13.669
20/16 1.332 2.087 2.17 3.119 4.03 12.639 14.417 14.010 15.195
18/20 1.456 2.936 3.16 2.824 4.85 14.741 13.702 15.624 14.932
18/18 1.589 3.017 2.88 3.429 4.58 16.088 15.694 17.092 16.829
18/16 1.728 3.078 2.65 4.077 4.30 17.215 17.683 18.326 18.638
16/20 1.853 3.977 3.51 3.396 4.87 18.505 16.533 19.128 17.813
16/18 1.998 4.087 3.25 4.000 4.66 20.203 18.647 20.909 19.872
16/16 2.136 4.172 3.03 4.687 4.44 21.667 20.823 22.448 21.886

Reactions at Supports (plf) Based on Web Crippling


Bearing Length of Webs
Beam Allowable (Rn/Ω) Factored (ΦRn)
Gage Condition 1" 2" 4" 8" 1" 2" 4" 8"
End 169 223 360 395 253 335 540 592
20
Interior 171 200 273 292 262 307 418 446
End 361 474 757 861 541 711 1136 1291
18
Interior 361 417 557 608 552 638 852 931
End 620 809 1282 1455 930 1213 1923 2182
16
Interior 621 710 934 1016 950 1087 1430 1555
End 1065 1380 2166 2453 1598 2069 3248 3680
14
Interior 1077 1221 1580 1711 1648 1868 2417 2619
Web Crippling Constraints h=7.2" r=0.125" θ=90º
172 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

7.5DF-24 7.17

GENERAL INFORMATION
3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 240 167 122 94 74 60 50 42 35 31 27
Φ fb 381 264 194 149 117 95 79 66 56 49 42
SS L/360 - - - - - - 49 37 29 24 19
L/240 - - - - - - - - - - -

2W PANELS
fb / Ω 297 206 151 116 92 74
Φ fb 471 327 240 184 145 118
20/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 371
Maximum
Φ fb 588
Product Length
TS L/360 -

B PANELS
L/240 -
fb / Ω 270 187 138 105 83 67 56 47 40 34 30
Φ fb 428 297 218 167 132 107 88 74 63 55 48
SS L/360 - - - - - - 54 41 33 26 21
L/240 - - - - - - - - - - -
fb / Ω 381 264 194 149 118 95
Φ fb 604 419 308 236 186 151
20/18 DS

N PANELS
L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 422
Maximum
Φ fb 669
Product Length
TS L/360 -
L/240 -
fb / Ω 275 191 140 107 85 69 57 48 41 35 31

C PANELS
Φ fb 436 303 223 170 135 109 90 76 65 56 48
SS L/360 - - - - - - - 44 35 28 23
L/240 - - - - - - - - - - -
fb / Ω 411 285 210 161 127 103
Φ fb 652 453 333 255 201 163
20/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
Maximum
D PANEL

fb / Ω 430
Φ fb 682
Product Length
TS L/360 -
-
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 173


TABLE OF CONTENTS

7.17 7.5DF-24
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)


Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 387 269 197 151 119 97 80 67 57 49 43
Φ fb 614 426 313 240 189 153 127 107 91 78 68
SS L/360 - - - - 117 85 64 49 39 31 25
L/240 - - - - - - - - - 47 38
fb / Ω 372 258 190 145 115 93
Φ fb 590 410 301 231 182 148
18/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 465
Maximum
Φ fb 738
Product Length
TS L/360 -
L/240 -
fb / Ω 397 276 203 155 123 99 82 69 59 51 44
Φ fb 631 438 322 246 195 158 130 109 93 80 70
SS L/360 - - - - - 93 70 54 43 34 28
L/240 - - - - - - - - - - 41
fb / Ω 452 314 230 176 139 113
Φ fb 717 498 366 280 221 179
18/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 565
Maximum
Φ fb 896
Product Length
TS L/360 -
L/240 -
fb / Ω 406 282 207 158 125 101 84 70 60 52 45
Φ fb 643 447 328 251 199 161 133 112 95 82 71
SS L/360 - - - - - 100 75 58 46 36 30
L/240 - - - - - - - - - - 44
fb / Ω 537 373 274 210 166 134
Φ fb 852 592 435 333 263 213
18/16 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 634
Maximum
Φ fb 1005
Product Length
TS L/360 -
-

174 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

7.5DF-24 7.17

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
Inward Allowable (fb/Ω) and Factored (Φfb) Distributed Load (lbs/ft2)
Limit Panel Span (Support Spacing)
Gage Span Condition 10' - 0" 12' - 0" 14' - 0" 16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0" 26' - 0" 28' - 0" 30' - 0"
fb / Ω 524 364 267 205 162 131 108 91 77 67 58
Φ fb 831 577 424 325 257 208 172 144 123 106 92
SS L/360 - - - 204 143 104 79 60 48 38 31

2W PANELS
L/240 - - - - - - - 91 71 57 46
fb / Ω 447 311 228 175 138 112
Φ fb 710 493 362 277 219 177
16/20 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 559
Maximum
Φ fb 887
Product Length
TS

B PANELS
L/360 -
L/240 -
fb / Ω 538 374 275 210 166 135 111 93 80 69 60
Φ fb 854 593 436 334 264 214 176 148 126 109 95
SS L/360 - - - - 157 114 86 66 52 42 34
L/240 - - - - - - - - 78 62 51
fb / Ω 527 366 269 206 163 132

N PANELS
Φ fb 836 581 426 327 258 209
16/18 DS L/360 - - - - - -
Exceeds
L/240 - - - - - -
fb / Ω 659
Maximum
Φ fb 1045
Product Length
TS L/360 -
L/240 -

C PANELS
fb / Ω 550 382 280 215 170 137 114 95 81 70 61
Φ fb 872 606 445 341 269 218 180 151 129 111 97
SS L/360 - - - - 168 123 92 71 56 45 36
L/240 - - - - - - - - - 67 55
fb / Ω 617 429 315 241 191 154
Φ fb 979 680 500 383 302 245
16/16 DS L/360 - - - - - -
Exceeds
D PANEL

L/240 - - - - - -
fb / Ω 772
Maximum
Φ fb 1224
Product Length
TS L/360 -
-
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 175


TABLE OF CONTENTS

7.18 7.5DF-24
Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

7.5DF-24 Shoring Table


145 pcf Normal Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 46.3 18' - 7" 20' - 0" 10' - 8"
20/18 46.9 19' - 8" 20' - 0" 10' - 8"
20/16 47.6 19' - 9" 20' - 0" 10' - 8"
18/20 47.6 23' - 5" 20' - 0" 10' - 8"
9 1.053 18/18 48.1 23' - 8" 20' - 0" 10' - 8"
18/16 48.8 23' - 9" 20' - 0" 10' - 8"
16/20 48.8 24' - 7" 20' - 0" 10' - 8"
16/18 49.3 25' - 1" 20' - 0" 10' - 8"
16/16 50.0 25' - 5" 20' - 0" 10' - 8"
20/20 58.4 17' - 2" 19' - 1" 10' - 8"
20/18 59.0 18' - 2" 20' - 0" 10' - 8"
20/16 59.7 18' - 3" 20' - 0" 10' - 8"
18/20 59.6 21' - 8" 20' - 0" 10' - 8"
10 1.361 18/18 60.2 21' - 10" 20' - 0" 10' - 8"
18/16 60.9 22' - 0" 20' - 0" 10' - 8"
16/20 60.8 23' - 4" 20' - 0" 10' - 8"
16/18 61.4 23' - 9" 20' - 0" 10' - 8"
16/16 62.1 24' - 2" 20' - 0" 10' - 8"
20/20 70.5 16' - 0" 17' - 10" 10' - 8"
20/18 71.1 16' - 11" 19' - 4" 10' - 8"
20/16 71.7 17' - 0" 19' - 5" 10' - 8"
18/20 71.7 20' - 2" 19' - 10" 10' - 8"
11 1.670 18/18 72.3 20' - 5" 20' - 0" 10' - 8"
18/16 72.9 20' - 7" 20' - 0" 10' - 8"
16/20 72.9 22' - 4" 20' - 0" 10' - 8"
16/18 73.5 22' - 9" 20' - 0" 10' - 8"
16/16 74.1 23' - 2" 20' - 0" 10' - 8"
20/20 82.6 15' - 1" 16' - 9" 10' - 8"
20/18 83.2 15' - 11" 18' - 2" 10' - 8"
20/16 83.8 16' - 1" 18' - 4" 10' - 8"
18/20 83.8 19' - 0" 18' - 8" 10' - 8"
12 1.979 18/18 84.4 19' - 3" 20' - 0" 10' - 8"
18/16 85.0 19' - 4" 20' - 0" 10' - 8"
16/20 85.0 21' - 6" 20' - 0" 10' - 8"
16/18 85.6 21' - 11" 20' - 0" 10' - 8"
16/16 86.2 22' - 4" 20' - 0" 10' - 8"
20/20 94.7 14' - 3" 15' - 11" 10' - 8"
20/18 95.3 15' - 1" 17' - 3" 10' - 8"
20/16 95.9 15' - 2" 17' - 4" 10' - 8"
18/20 95.9 18' - 0" 17' - 8" 10' - 8"
13 2.287 18/18 96.5 18' - 3" 19' - 5" 10' - 8"
18/16 96.5 18' - 3" 19' - 5" 10' - 8"
16/20 97.1 20' - 10" 19' - 4" 10' - 8"
16/18 97.7 21' - 1" 20' - 0" 10' - 8"
16/16 98.3 21' - 3" 20' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
176 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com
TABLE OF CONTENTS

7.5DF-24 7.18

GENERAL INFORMATION
Light Weight Concrete (110 pcf)
Maximum Unshored Spans

3W PANELS
7.5DF-24 Shoring Table
145 pcf Light Weight Concrete
Total Slab Depth Volume Slab and Deck Maximum Unshored Span
(in) cy/100sf Gage psf Single Double Triple
20/20 36.4 20' - 4" 20' - 0" 10' - 8"
20/18 37.0 21' - 5" 20' - 0" 10' - 8"
20/16 37.6 21' - 7" 20' - 0" 10' - 8"

2W PANELS
18/20 37.6 25' - 0" 20' - 0" 10' - 8"
9 1.053 18/18 38.2 25' - 5" 20' - 0" 10' - 8"
18/16 38.8 25' - 9" 20' - 0" 10' - 8"
16/20 38.8 26' - 1" 20' - 0" 10' - 8"
16/18 39.4 26' - 7" 20' - 0" 10' - 8"
16/16 40.0 26' - 11" 20' - 0" 10' - 8"
20/20 45.6 18' - 10" 20' - 0" 10' - 8"
20/18 46.2 19' - 11" 20' - 0" 10' - 8"
20/16 46.8 20' - 0" 20' - 0" 10' - 8"

B PANELS
18/20 46.8 23' - 8" 20' - 0" 10' - 8"
10 1.361 18/18 47.4 23' - 11" 20' - 0" 10' - 8"
18/16 48.0 24' - 1" 20' - 0" 10' - 8"
16/20 48.0 24' - 9" 20' - 0" 10' - 8"
16/18 48.6 25' - 3" 20' - 0" 10' - 8"
16/16 49.2 25' - 8" 20' - 0" 10' - 8"
20/20 54.8 17' - 8" 19' - 8" 10' - 8"
20/18 55.3 18' - 8" 20' - 0" 10' - 8"

N PANELS
20/16 55.9 18' - 9" 20' - 0" 10' - 8"
18/20 56.0 22' - 3" 20' - 0" 10' - 8"
11 1.670 18/18 56.5 22' - 6" 20' - 0" 10' - 8"
18/16 57.1 22' - 8" 20' - 0" 10' - 8"
16/20 57.2 23' - 9" 20' - 0" 10' - 8"
16/18 57.7 24' - 3" 20' - 0" 10' - 8"
16/16 58.3 24' - 7" 20' - 0" 10' - 8"
20/20 63.9 16' - 9" 18' - 7" 10' - 8"

C PANELS
20/18 64.5 17' - 8" 20' - 0" 10' - 8"
20/16 65.1 17' - 9" 20' - 0" 10' - 8"
18/20 65.1 21' - 1" 20' - 0" 10' - 8"
12 1.979 18/18 65.7 21' - 3" 20' - 0" 10' - 8"
18/16 66.3 21' - 5" 20' - 0" 10' - 8"
16/20 66.3 22' - 11" 20' - 0" 10' - 8"
16/18 66.9 23' - 5" 20' - 0" 10' - 8"
16/16 67.5 23' - 9" 20' - 0" 10' - 8"
D PANEL

20/20 73.1 15' - 11" 17' - 8" 10' - 8"


20/18 73.7 16' - 10" 19' - 2" 10' - 8"
20/16 74.3 16' - 11" 19' - 3" 10' - 8"
18/20 74.3 20' - 0" 19' - 8" 10' - 8"
13 2.287 18/18 74.9 20' - 3" 20' - 0" 10' - 8"
18/16 75.5 20' - 5" 20' - 0" 10' - 8"
16/20 75.5 22' - 2" 20' - 0" 10' - 8"
16/18 76.1 22' - 8" 20' - 0" 10' - 8"
ACUSTADEK®

16/16 76.7 23' - 0" 20' - 0" 10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.
www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 177
TABLE OF CONTENTS

8.1 Acustadek®

Acustadek®
Acustadek provides the extraordinary beauty of exposed The sound absorption coefficient varies across the spectrum
steel, while providing the same noise reduction performance of audible sound. In buildings with equipment which creates
of common Mineral Fiber, Fiberglass, and Bio Acoustic a specific frequency, the sound absorption coefficient for that
ceiling tile systems. It is an excellent option for reducing noise frequency range should determine the type of deck rather than
inside buildings, increasing the comfort for the occupants. the overall NRC rating.
Acustadek is a dual-purpose panel which helps lower costs
by providing an interior finish while contributing to the The NRC should not be confused with the Sound Transmission
structural performance of the building. This is accomplished Coefficient (STC). STCs measure the blocking of sound
by perforating the structural steel deck and adding fiberglass through an assembly as it relates to the decibel drop in the
batt acoustic media in the webs or in the cells of cellular deck, intensity of the sound. Acustadek may not be a good choice if
turning the profile into Acustadek. Our new Smooth Series™ a high STC is required. As an example, consider a room with
rivets offer a clean attachment solution for the Acustadek noisy equipment. The Acustadek may be a good solution to
cellular deck system. reduce the noise level in the room for the occupants, but may
not be a good material to block the noise from escaping the
Cellular Acustadek® room. The holes in the perforated Acustadek may in fact let
Cellular Acustadek has 0.157” diameter holes spaced 0.433” more sound escape the room than a conventional deck.
inches on center in the sections of the pan below the top flutes
of the steel deck. Fiberglass batts are factory inserted in the Detailing and Installation of Acustadek®
cells of the deck before shipping to the project locations. Any Acustadek provides an exposed finish in the building. Steel
roof system utilizing structural or insulating concrete fill, rigid deck is a structural element in the building and is subject to
insulation board, or other roof substrate material suitable for incidental dents in the handling and steel erection process.
installation on a steel roof deck may be applied to the cellular To minimize the potential damage use 20 gage or heavier. 22
Acustadek. gage may be an economical option when minor dents can be
tolerated; dark paint finishes or high roof structures can mask
these types of minor blemishes.

Acustadek can be specified with a galvanized finish or


factory prime painted over galvanized steel. Most Acustadeks
will receive finish paint to meet the aesthetic requirements
of the building. The galvanized steel can be field painted
following the paint manufacturer’s preparation and application
recommendations. As an option, factory-applied primer can
be specified, which may reduce the surface preparation of
the deck.

Fiberglass Batts Attaching the Acustadek to the structure and connection of


Fiberglass batts are used to absorb sound in the Acustadek the side laps of the deck can impact the appearance of the
assemblies. ASC Steel Deck supplies the fiberglass batts installed product. Side lap top seam welds will leave burn
which are cut to size for the specified profile. The standard marks on the galvanized finish and an occasional burn through
batts are unfaced. Optional batts encapsulated with 0.75 mil should be expected. This may be unsightly if the galvanized
clear pvc plastic can be specified. finish is intended to be left exposed. The burns can be easily
cleaned up prior to prime painting the deck after installation.
Acoustical Performance A better solution, however, is to use the DeltaGrip® side lap
All Acustadeks have been tested for the sound absorption connection. This mechanical interlock connection provides
characteristics of the assemblies. This is commonly presented high strength similar to a weld without any thermal damage
as a Noise Reduction Coefficient (NRC). The NRC is the average to the deck or galvanized coating, and is not visible from the
of the 250, 500, 1000, and 2000 hertz sound absorption underside of the deck. Arc spot and arc seam welds may also
coefficients. Acustadeks have between a 0.6 and 1.0 NRC. leave visible burn marks on the deck near the support or on
the underside of the supporting steel. A good alternative to
Acustadek should be a portion of a holistic approach to welding the deck to supports is to attach the deck with self-
reducing the noise level in a building. Simply specifying an drilling screws or power-actuated fasteners (PAF), such as
NRC rating for a single material may not get the level of the high shear nails manufactured by Hilti, Inc. or fasteners
sound control you require. In general, steel deck tend to have manufactured by Pneutek Inc. which are intended for decking
better sound absorption coefficients in the higher audible applications.
range. Other materials such as fabric wall treatments and
carpet tend to have better sound absorption coefficients in Structural Performance of Acustadek®
the lower audible frequency ranges. The use of Acustadek in The Acustadek perforations have a small impact on the
combination with other materials may create the best overall structural performance of the deck profiles. Section properties
quiet environment. An experienced acoustic designer is key are reduced from the non-Acustadek version of the profiles
to developing the best overall performance using ASC Steel leading to reduced vertical load capacity. The reactions at
Deck Acustadek products. supports are unaffected by the perforations in the Acustadek.

178 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Acustadek® 8.2

GENERAL INFORMATION
Sound Absorption Data
Absorption Coefficient1
Acustadek® Profile Noise Reduction
(Perforation Type) Batt 2
125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Coefficient1

Unfaced 0.20 0.45 0.77 1.09 0.84 0.56 0.80

3W PANELS
Encapsulated 0.16 0.37 0.70 1.01 0.64 0.49 0.70
BHF-36A

Unfaced 0.44 0.57 1.08 1.00 0.82 0.63 0.85


5″

2W PANELS
Encapsulated 0.49 0.63 1.17 0.93 0.72 0.48 0.85
NHF-32A

Unfaced 0.43 0.49 0.80 0.86 0.67 0.56 0.70

Encapsulated 0.38 0.42 0.79 0.79 0.48 0.41 0.60

B PANELS
2WHF-36A

Unfaced 0.58 0.53 0.98 0.85 0.66 0.52 0.75

Encapsulated 0.60 0.79 0.66 0.50 0.46 0.46 0.60


3WxHF-36A

N PANELS
Unfaced 0.40 0.75 0.83 0.68 0.70 0.54 0.75

Encapsulated 0.58 0.91 0.93 0.68 0.59 0.46 0.80


4.5DF-24A

C PANELS
Unfaced 0.40 0.89 0.85 0.72 0.70 0.53 0.80

Encapsulated 0.53 0.88 0.82 0.70 0.63 0.52 0.75


6DF-24A

Unfaced 0.78 0.99 0.86 0.79 0.72 0.52 0.85


D PANEL

Encapsulated 0.84 0.93 0.79 0.75 0.65 0.93 0.80


7.5DF-24A

Table Notes:
1. Noise reduction coefficient testing was conducted in accordance with ASTM C423 and ASTM E795.
2. Unfaced or encapsulated fiberglass batts wrapped with clear plastic film.
ACUSTADEK®

www.ascsd.com Composite and Non-Composite Deck Catalog • February 2016 179


TABLE OF CONTENTS

Metric Conversion Chart

Metric Conversions
Multiply By To Obtain
Spans, length & thickness Inches 25.4 Millimeters
Feet 304.8 Millimeters
Inches 0.0254 Metres
Feet 0.3048 Metres
Vertical Load & Superimposed Load psf 0.0479 kPa
psi 6.8948 kPa
Area Square feet 0.0929 Square Metre
Square 9.2903 Square Metre
Diaphragm Shear plf 0.0146 KN/m
Section Properties in3/ft 53,763 mm3/m
in /ft
4
1,365,588 mm4/m
in3/ft 53.763 cm3/m
in4/ft 136.559 cm4/m
Weight Pounds 0.00445 kN
psf 4.8824 kg/m2
 Volume pcf 16.018 kg/m3

180 Composite and Non-Composite Deck Catalog • February 2016 www.ascsd.com


TABLE OF CONTENTS

Evolution of Company
ASC Steel Deck has provided structural steel roof and
floor deck throughout the Western United States since the
1970s. Over this time, ASC Steel Deck has undergone a few
ownership changes and operated under different business
names (ASC Pacific, BHP Steel Building Products, and IMSA
Building Products). Since 2002, however, we have operated
under the name ASC Steel Deck, a division of ASC Profiles
LLC. While the name of the company has changed over
the years, the continuous dedication to product innovation,
high quality steel deck products, and customer service has
positioned ASC Steel Deck as a leader in the industry.

Industry Innovator
With an outward focus on the steel deck industry, ASC Steel Deck has led the way and established itself as a leader
having accomplished many industry-firsts. ASC Steel Deck was the first West Coast manufacturer to incorporate
diaphragm Shear and superimposed load tables based on ANSI/SDI C-2011 Standard for Composite Steel Floor Deck-
Slabs. This standard has been adopted for inclusion in the 2015 IBC.

ASC Steel Deck has also led the way in providing innovative products which reduce installation costs, while offering some
of the highest diaphragm shear values in the market. For example:

• 36/7/4 Attachment Pattern - reduces attachment requirements for 11⁄2" roof deck by up to 30%.

• N-32® Roof Deck - A 3" deep roof deck profile providing a 10% improvement in steel utilization and up to 20% reduction
in installation costs as compared to the industry standard N-24 panel.

Whether through product re-engineering or new product development, ASC Steel Deck strives for constant improvement
through innovation.
TABLE OF CONTENTS

Manufacturing Facilities

ASC Steel Deck • Sacramento, CA


2110 Enterprise Boulevard
West Sacramento, CA 95691
916-372-6851
800-726-2727

ASC Steel Deck • Fontana, CA


10905 Beech Avenue
Fontana, CA 92337

Visit us at:
www.ascsd.com

©2016 ASC Profiles LLC All trademarks are the property of their respective owners. All rights reserved. Version 1.0 0216 Pub February 2016 (DL021)

You might also like