You are on page 1of 7

INPUT VALUES

SUCTION:
Inlet pressure P1 66.2 bara 67.491 kg/cm2a
Inlet Temperature T1 -11.7 °C 261.45 °K Mandatory to be filled
Molecular weight MW 19.41 calculated values
Cp/Cv K1 1.27
Compressibility Z1 0.73
Weight flow ṁ 199421 kg/hr
Speed N 7370 rpm
Polytropc head Hp 13180 kgm/kg by vendor
Polytropic efficiency ηp 84 % by vendor
DISCHARGE:
Discharge pressure P2 16.9 bara 17.230 kg/cm2a
Discharge Temperature T2 -66.7 °C 206.45 °K by vendor
Cp/Cv K2 1.22
Compressibility Z2 0.88

Hpcalculation
Polytropic head = (n/n-1) Zavg R T1H[(P
p 2/P1)
(n-1/n)
-1]

η = (n/n-1) / (Kavg /K -1)


Calculation of (n/n-1) : p avg
ηp = (n/n-1) / (Kavg /K -1) avg

(n/n-1) = 4.27 Kavg 1.25


Therefore,
Hp = -105344 Nm/Kg
Hp = -10742 Kgf m/Kg 1J/kg= 0.101972 Kgfm/kg
T2 = T1 [(P2/P1)(n-1/n)]
Discharge temperature calculation T2

Therefore

T2= 189.9 °K
T2= -83.3 °C
No. of stages

Q = Square root [(14.5X MW) / (K1Z T1)]


1
Q= 1.078
No. of stages = Hp / Max. polytropic head/stage
As per table the max number of stage have to be evaluated from the above Q value and graph

Max. polytropic head/stages = 36

Therefore

No. of stages = -2.9


Gas power = ṁ x~Hp / 3600
No. of stages -3 x ηp
Shaft Power :

Shaft power = Gas power+Mech losses

Gas power = -6947.0 KW

Motor power = shaft power X factor

Based on the above table, we need to input the mechanical losses

Mechanical losses 3 %

Shaft power = -7155.4 KW


Factor = 116%

Motor power = -8289 KW


Gas Turbine Derating
Standard ISO rating:
Temperature 15 °C
Humidity 60 %
Level 0 sea level

Machine condition
Temperature 45 °C 30 °C increase
Local level 450 m above sea 450 m

Rated output 25000 KW

Derated output 18363 KW