ABSTRACT:
There are currently a number of buildings in excess of 300m under construction in the world and further tall
buildings are planned for both residential and commercial markets. The design and construction of tall build-
ings present many challenges for the design team, from engineers, Architect through to the concrete technolo-
gist and the builder. Both safety and sustainability aspects are important in planning and designing tall build-
ings. Current practice, trends, improvements and some mistakes in designing buildings will be highlighted in
this key note address.
36
Electronic Journal of Structural Engineering 13(1) 2013
classified according to the region and the usage as these, economics has been the primary governing
shown in Figures 2(a) and 2(b). CTBUH estimated factor. However, construction of super tall buildings
that by the end of the decade, the number of super itself would not have been possible without support-
tall buildings in the world, especially in Asia, would ing technologies. Structural systems for tall build-
more than double as shown in Figs 2(a) & 2(b). It is ings have undergone dramatic changes since the de-
very clear that the epicenter for super tall buildings mise of the conventional rigid frames in the 1960s as
is moving towards Asia. the predominant type of structural system for steel or
concrete tall buildings (Ali and Moon, 2007). How-
ever, the structural form of a tall building is influ-
enced strongly by its function, whilst having to satis-
fy the requirements of strength and serviceability
under all probable conditions of gravity and lateral
loads. The latest developments in the design of tall
buildings are the innovations in construction tech-
nology, advances in structural systems and im-
provements in concrete technology (ultra high
strength concrete) (Mendis, 2001).
Over the past five decades, six categories have
been identified to classify tall building structural sys-
tems. These are:
i. framed tube (system of rigid frames)
2(a) ii. bundled tube (combination of framed tubes)
iii. tube in tube (central and peripheral framed tubes)
iv. diagonalised (trussed tubes, diagrids or braced
frames)
v. core + outrigger (central lateral system linked to
the perimeter system through outriggers)
vi. hybrid (combined use of any two or more struc-
tural systems).
Core and outrigger system is a common and very
popular system among the other systems. In total,
73% of the tall buildings built in the 2000s have
adopted a core + outrigger system, and approximate-
ly 50% of them are constructed with concrete
2(b) (CTBUH, 2010). Figure 3 shows the tall buildings
marked according to these categories.
Figure 2(a) Total number of super tall buildings in the world by
region; 2(b) Total number of super tall buildings in the world
by usage 3 WIND LOADS FOR DESIGN OF TALL BUILD-
INGS
2.1 Structural and Architectural evolution 3.1 Types of Wind Designs
The significance of lateral loading increases with in- Lateral loading due to either wind and/or seismic
creasing height, in terms of serviceability, strength loading, generally dominates the structural system of
and stability limit states. For the taller and more very tall buildings, therefore significantly influenc-
slender buildings the structural form becomes in- ing the overall structural cost. Wind is a phenome-
creasingly important. The structural system for tall non of great complexity because of the many flow
buildings can essentially be broken down into two situations arising from the interaction of wind with
distinct categories. They are the gravity load resist- structures. Wind is composed of a multitude of ed-
ing structural system (GLRSS) and the lateral load dies of varying sizes and rotational characteristics
resisting structural system (LLRSS). carried along in a general stream of air moving rela-
Tall building development involves various com- tive to the earth’s surface. These eddies give wind its
plex factors, such as economics, aesthetics, technol- gusty or turbulent character. Typically for tall build-
ogy, municipal regulations, and politics. Among
37
Electronic Journal of Structural Engineering 13(1) 2013
ing design three basic wind effects need to be con- cost of typical facade systems in proportion to the
sidered. overall cost of very tall buildings, engineers cannot
Environmental wind studies to study the wind ef- afford the luxury of conservatism in assessing design
fects on the surrounding environment caused by wind loads. With due consideration to the complex
erecting a tall building. This study is particularly im- building shapes and dynamic characteristics of the
portant to assess the impact of wind on pedestrians wind and building structure, even the most advanced
and motor vehicles etc., which utilise public domain wind codes generally cannot accurately assess design
within the vicinity of the proposed structure. loads. Wind tunnel tests to assess design loads for
Wind loads for facade – to assess design wind cladding, is now a normal industry practice, with the
pressures throughout the surface area of the building aim to minimize initial capital costs, and more sig-
to design the cladding system. Due to the significant nificantly to avoid expensive maintenance costs as-
Figure 3: Structural system categorization for tall buildings completed 1961-2010 (Modified from CTBUH, 2010)
38
Electronic Journal of Structural Engineering 13(1) 2013
sociated with malfunctions due to leakage and/or 3.3 Background to Wind Loading
structural failure. Not only is the wind approaching a building a com-
Wind loads for structure – to determine the wind plex phenomenon, but the flow pattern generated
loads to design the lateral load resisting structural around a building is complicated by the distortion of
system of the building to satisfy the various design the mean flow, the flow separation, the vortex for-
criteria. mation, and the wake development. Large wind
pressure fluctuations due to these effects occur on
3.2 Criteria Design the surface of a building. As a result, large aerody-
In terms of designing a tall building for lateral wind namic loads are imposed on the structural system
loads the following design criteria needs to be satis- and intense localised fluctuating forces act on the fa-
fied. The three design criteria that are considered in cade of such structures. Under the collective influ-
wind design are stability, strength and serviceability. ence of these fluctuating forces, a building vibrates
As adopted by most international codes, to satisfy in rectilinear and torsional modes, as illustrated in
stability and strength limit states requirements, ulti- Figure 4. The amplitude of such oscillations is de-
mate limit state wind speed (e.g. 1 in 1000 year re- pendent on the nature of aerodynamic forces and the
turn periods) is used. dynamic characteristics of the building.
In majority of the super tall buildings designed
now, accelerations govern the overall selection and 3.4 Along-wind Loading
design of the structural system. Acceptability criteria The along-wind loading or response of a building
for vibrations in buildings are frequently expressed due to the gusting wind can be assumed to consist of
in terms of acceleration limits for a one or five years a mean component due to the action of the mean
return period wind speed and are based on human wind speed (eg, the mean-hourly wind speed) and a
tolerance to vibration discomfort in the upper levels fluctuating component due to wind speed variations
of buildings. Wind response is relatively sensitive to from the mean. The fluctuating wind is a random
both mass and stiffness, and response accelerations mixture of gusts or eddies of various sizes with the
can be reduced by increasing either or both of these larger eddies occurring less often (i.e. with a lower
parameters. However, this is in conflict with earth- average frequency) than smaller eddies. The natural
quake design optimization where loads are mini- frequency of vibration of most structures is suffi-
mized in tall buildings by reducing both the mass ciently higher than the component of the fluctuating
and stiffness. Increasing the damping, results in a re- load effect imposed by the larger eddies. i.e. the av-
duction in both the wind and earthquake responses. erage frequency with which large gusts occur is usu-
The detailed procedure described in the Code is ally much less than any of the structure's natural fre-
sub-divided into Static Analysis and Dynamic Anal- quencies of vibration and so they do not force the
ysis methods. The static approach is based on quasi- structure to respond dynamically. The loading due to
steady assumption; it assumes that the building is a those larger gusts (which are sometimes referred to
fixed rigid body in the wind. Static method is not as "background turbulence") can therefore be treated
appropriate for tall buildings of unexceptional in similar way as that due to the mean wind. The
height, slenderness, or susceptibility to vibration in smaller eddies, however, because they occur more
the wind. In practice, static analysis is normally ap- often, may induce the structure to vibrate at or near
propriate for structures up to 50 metres in height. one of the structure's natural frequencies of vibra-
The dynamic method is developed for exceptionally tion. This in turn induces a magnified dynamic load
tall, slender, or vibration-prone buildings. Usually a effect in the structure which can be significant.
dynamic analysis must be undertaken to determine The separation of wind loading into mean and
overall forces on any structure with both a height fluctuating components is the basis of the so-called
(and length) to breadth ratio greater than five and a "Gust-factor" approach or more recently presented as
first mode frequency less than 1 Hertz. Approximate “Dynamic response factor”, which is introduced in
frequency of a building is 46/height. Therefore gen- major wind codes around the world. The mean load
erally slender buildings with 50 m height are wind component is evaluated from the mean wind speed
sensitive as mentioned earlier. using pressure and load coefficients. The fluctuating
loads are determined separately by a method which
makes an allowance for the intensity of turbulence at
the site, size reduction effects, and dynamic amplifi-
cation.
39
Electronic Journal of Structural Engineering 13(1) 2013
The dynamic response of buildings in the along- has inhibited reliable theoretical predictions. How-
wind direction can be predicted with reasonable ac- ever, empirical information obtained from wind tun-
curacy by this approach, provided the wind flow is nel measurements is available for cross-wind re-
not significantly affected by the presence of neigh- sponse of tall buildings not subjected to interference
boring tall buildings or surrounding terrain. effects, and expressions based on such information
appear in the AS 1170.2 -2011(Australian Wind
3.5 Cross-Wind Loading Code). The response of the tall buildings to wind de-
Tall buildings are bluff (as opposed to streamlined) pends on its shape, stiffness distribution, mass dis-
bodies that cause the flow to separate from the sur- tribution and damping. Some common problems as-
face of the structure, rather than follow the body sociated with wind loading for base of tall buildings
contour. The wake flow thus created behind the are shown in Figure 5.
building exhibits various degrees of periodicity,
ranging from virtually periodic with a single fre-
quency to fully random. In each of the cases, at any
given instant, the wake flow is asymmetrical. The
across-wind response (i.e., motion in a plane per-
pendicular to the wind direction) is due to the
asymmetry, although the lateral turbulent fluctua-
tions in the oncoming flow may also contribute to
the across-wind forces.
Figure 5: Wind related problems in Tall buildings (From inter-
net sources)
40
Electronic Journal of Structural Engineering 13(1) 2013
these methods will be used more often than experi- Acceleration limits are a function of the frequency of
mental techniques to predict the wind behaviour the vibration felt. Upper limits have been recom-
around the super tall buildings including pedestrian mended for corresponding frequencies of vibration
comfort at the base of the building. with the relationship suggested by Irwin and these
are widely used around the world. Other peak accel-
3.7 Comfort criteria: Human response to building eration limits are also plotted along with the Irwin’s
motion E2 curve in Figure 6.
There are no generally accepted international stand-
ards for comfort criteria in tall building design after
decades of research. A considerable amount of re-
search has however been carried out into the im-
portant physiological and psychological parameters
that affect human perception to motion and vibration
in the low frequency range of 0-1 Hz encountered in
tall buildings. These parameters include the occu-
pant’s expectancy and experience, their activity,
body posture and orientation, visual and acoustic Figure 6: Horizontal acceleration criteria for occupancy com-
cues, and the amplitude, frequency, and accelera- fort in buildings
tions for both the translational and rotational mo-
tions to which the occupant is subjected. Table 1 3.8 Earthquake design for tall buildings
gives some guidelines on general human perception In general, tall buildings respond to seismic motion
levels. More information can be found in Mendis et in a different manner than low-rise buildings due to
al, (2007). the flexibility of these buildings. The design of these
Generally the acceleration is the predominant pa- tall buildings in seismically active regions varies
rameter in determining the nature of human response dramatically from region to region. It is well known
to vibration, and this, with knowledge of the fre- that the behaviour of a structure during an earth-
quency of oscillation, can define all other relevant quake depends on two basic parameters: (a) the in-
parameters of sinusoidal vibration. Human percep- tensity of the earthquake, and (b) the quality of the
tion levels for different accelerations suggested by structure. The quality of the structure is a parameter
Yamada and Goto (1975) are listed in the following that exhibits a sufficient level of reliability, since it
table: depends on the configuration of the structural sys-
tem, the design procedure, the detailing of the struc-
Table 1: Human Perception Levels tural elements and careful construction.
Acceleration Analysis procedures for buildings can be classified
Level (m / sec2) Effect as force-based design and performance-based design.
1 <0.05 Humans cannot perceive motion
a) Sensitive people can perceive mo-
Traditionally, seismic structural design has been
tion; based primarily on forces. However, the economic
2 0.05 - 0.1 b) hanging objects may move slightly losses resulting from several earthquakes, has
a) Majority of people will perceive
motion;
prompted the earthquake engineering community to
b) level of motion may affect desk embrace the concept of performance-based earth-
work: quake engineering. Although the basic objective of
c) long - term exposure may produce
3 0.1 - 0.25 motion sickness
performance-based earthquake engineering is to pro-
a) Desk work becomes difficult or duce structures that respond in a more reliable man-
almost impossible; ner during earthquake shaking, many engineers asso-
4 0.25 - 0.4 b) ambulation still possible
a) People strongly perceive motion; ciate performance-based earthquake engineering
b) difficult to walk naturally; with overall enhanced performance. Design profes-
5 0.4 - 0.5 c) standing people may lose balance. sionals in the USA have come to believe that the de-
Most people cannot tolerate motion
6 0.5 - 0.6 and are unable to walk naturally sign of tall buildings using the current US building
People cannot walk or tolerate mo- code does not allow for the best use of structural sys-
7 0.6 - 0.7 tion. tems and building materials to provide safe and pre-
Objects begin to fall and people may
8 >0.85 be injured dictable performance when subjected to strong
earthquake ground motions (Lew, 2007).
41
Electronic Journal of Structural Engineering 13(1) 2013
In performance-based design, Structural Engineers rect displacement based design for outrigger braced
Association of California SEAOC (1999) suggested tall buildings. A systematic approach was presented
the following levels for the design and verification for the calculation of design displacement profile
of tall buildings: based on the moment profiles of the outrigger braced
tall buildings by Herath (2011).
Table 2: Earthquake levels for the design of tall buildings
Recurrence Probability of exceed-
Event Interval ance Traditional engineering practice is mainly focused
Frequent 43 years 50% in 30 years on only first translational mode when setting
Occasional 72 years 50% in 50 years strength requirements and lateral force distributions
Rare 475 years 10% in 50 years in earthquake design for buildings. As mentioned
Very rare 975 years 10% in 100 years
earlier, the reason behind this phenomenon was that
most of the existing building codes of practice were
In 2005, the Los Angeles Tall Buildings Structural developed based on the behaviour of low-rise build-
Design Council (LATBSDC) produced an alterna- ings, which are not influenced much by higher mode
tive procedure for a performance-based approach to effects. However the higher mode participation in
seismic design and analysis of tall buildings. This al- tall buildings cannot be neglected as there is a signif-
ternative procedure was revised and updated in 2008 icant impact from these mode responses for the
(LATBSDC, 2008). The procedure given in LAT- overall response of the building. A study conducted
BSDC (2008) is based on capacity design principles, at University of Melbourne investigated the higher
followed by a series of state-of-the-art performance- mode participation in the design of tall buildings un-
based design evaluations. Capacity design principles der earthquake loads for outrigger braced tall build-
are applied first to design the structure to have a ings and the significant impact on the behaviour of
suitable ductile yielding mechanism, or mechanisms, such buildings from higher mode participation in-
under non-linear lateral deformations. Then linear cluding period lengthening was highlighted (Herath,
analysis is used to determine the required strength of 2011).
the yielding actions.
Although there are many methods available for the
seismic analysis of buildings, there is a common ac-
ceptance within the community that the existing
methods are not very suitable for the analysis of very
tall buildings, since most of these methods were de-
rived based on low- to medium-rise buildings.
Moreover as discussed above, the methods that are
available for the seismic design for tall buildings
consume a considerable amount of time for the anal-
ysis even with the use of sophisticated computers.
Therefore a simple and versatile method was devel-
oped, at the University of Melbourne, based on di- Table 2: Earthquake levels for the design of tall buildings
Accidental Material Material Strength
Design / Ground Type of
Type of Torsion Reduction
Evaluation Motion Mathematical
Analysis Considered? Factors
Step Intensity1 Model
(φ)
1 Non-linear Behaviour Defined / Capacity Design
2 50/30 LDP2 or 3D4 Evaluated 1.0 Expected properties are used throughout,
3
NDP except when calculating the capacity of
3 MCE5 NDP 3D4 Yes, if 1.0 brittle elements where
flagged dur- specified strength values shall be used.
ing Step 2.
No, other-
wise.
1 probability of exceedance in percent / number of years
2 linear dynamic procedures
3 non-linear dynamic procedures
4 three-dimensional
5 per (ASCE, 2005)
42
Electronic Journal of Structural Engineering 13(1) 2013
43
Electronic Journal of Structural Engineering 13(1) 2013
equivalent amount of TNT), and the standoff dis- Table 1: Table 4:Peak reflected overpressures (MPa) with dif-
tance (R) between the blast source and the target. For ferent W-R combinations (TM5-1300, 1990)
W
example, the blast occurred at the basement of
100 kg 500 kg 1 ton 2 ton
World Trade Centre in 1993 has the charge weight R TNT TNT TNT TNT
of 816.5 kg TNT. The Oklahoma bomb in 1995 has 1m 973 4883 9769 19543
a charge weight of 1814 kg at a standoff of 4.75m 2.5m 59 309 622 1247
(Longinow, 1996). 5m 6.1 36 75 153
With the detonation of a mass of TNT at or near 10m 0.7 3.9 7.8 17.03
15m 0.2 1.0 2.2 4.72
the ground surface, the peak blast pressures resulting
20m 0.1 0.4 0.87 1.82
from this hemispherical explosion decay as a func-
tion of the distance from the source as the expanding
3.11 Aircraft impact loading
shock front dissipates with range (Figure. 10). The
It is essential to design tall buildings for at least an
incident peak pressures are amplified by a reflection
impact from a small aircraft. Design loads resulting
factor as the shock wave encounters an object or
from aircraft impacts are governed by the absorption
structure in its path. The reflected pressure is at least
of kinetic energy from the aircraft by the building at
twice that of the incident shock wave and is propor-
its maximum deflection. These loads are limited by
tional to the strength of the incident shock, which is
the yield, buckling and crushing of the aircraft. Total
proportional to the charge weight. The blast pressure
impactive load F(t) at the interface of the collapsing
decays exponentially and eventually becomes nega-
aircraft and the building is given by Kar, (1979):
tive as shown in Figure 11. Then the building is sub-
F(t) = Fc + μ [m(t)] V(t)
jected to pressures acting in the direction opposite
Where m(t) is the mass of the aircraft reaching the
(suction pressure) to that of the original shock front.
building per unit time;
Peak blast loads may be several orders of magnitude
- μ is a coefficient for change in momentum (which
larger than the largest loads for which conventional
can be taken conservatively as 1);
buildings are designed (Table 4).
- Fc is a constant which can be determined from the
design acceleration for failure of the aircraft;
- V(t) is the velocity of the aircraft.
44
Electronic Journal of Structural Engineering 13(1) 2013
45
Electronic Journal of Structural Engineering 13(1) 2013
has been called into question in the aftermath of are associated with construction, operation and
9/11. A large amount of fireproofing was dislodged maintenance of buildings (Smith, 2005).
from the steel members as a result of the initial im- Historically, tall buildings have been perceived as
pact and the explosion of the aircraft. Questions inefficient users of energy. However, with time, their
have been raised as to whether the fire-proofing role in supporting the sustainable growth of cities
should be thickened, and whether there is a require- was gradually increased and tall buildings were con-
ment to develop new products to improve the bond- sidered sustainable structures as they optimize the
ing to the structural members at elevated tempera- use of limited land resources (Smith, 2007). Con-
tures. structing tall buildings poses inherent challenges to
The fire designs carried out now are based on stand- safe and efficient movement of people, materials and
ard fires. Fires originating from jet fuel, such as in equipment.
the WTC, are hydrocarbon fires, which are different By close collaboration between architects and
to standard fires. In hydrocarbon fires the tempera- structural engineers, many wonderful and well-
ture increases rapidly (in a few seconds) compared to designed buildings have been built all over the
a standard fire, in which the maximum temperature world. However, with the increasing concern over
is reached after some time. Concrete, which is the the environment, the engineer finds themselves once
main construction material for tall buildings, is sus- again faced with new challenges. This time, the chal-
ceptible to shattering (spalling) under rapid and high lenge is to find out how the structure can fit within
intensity heat; for example, following the ignition of the energy conservation strategy. Generally 75% of
hydrocarbon fuel. Even steel members may behave the energy consumption in high rise buildings is al-
differently under a hydrocarbon fire. The collabora- located for heating, ventilation and air conditioning
tive research project at the University of Melbourne (Yeang, 1999). A study conducted on high rise office
conducted by Quynh Nguyen (with Permasteelisa buildings in Malaysia supported that study and it was
Ltd) will investigate the fire performance of new concluded that 57% of energy is used for air condi-
generation GFRP facades in tall buildings. As tall tioning and lighting, lifts and pumps and other
buildings continue to be built to meet the need for equipment consume 19%, 18% and 6% respectively.
space in cities, it is essential for planners and build- Studies on the total energy usage in these tall build-
ers to pay attention to disasters that have already oc- ings during the life cycle of the buildings are crucial
curred, to visualise the possibility of these events in as these tall buildings consume large amount of en-
the future, and conduct research and development ergy as described above. Life cycle energy consump-
work that mobilises the support of practising engi- tion requires a comprehensive energy analysis to
neers and scientific personnel, including collaborat- cover energy consumption throughout the lifespan of
ing with specialists in universities and other research the building. In life-cycle energy analysis (LCEA),
organisations. This will mean that designers will the energy embodied in a building and the energy
begin to do things differently, and this will enhance used in the operation of the building are calculated
the safety of the occupants of tall buildings that are for the anticipated lifetime of the building. However
susceptible to extreme loads (Mendis and Ngo, in tall buildings, the energy consumption for vertical
2006). transportation is also very important and this com-
ponent needs to be addressed in the energy consump-
3.13 Sustainable design of tall buildings tion calculations.
Integrated design is different than conventional
Sustainable design, which is one of the most im- design in its focus on active collaboration within a
portant considerations in any building project these multidisciplinary team. In sustainable tall buildings
days, implies many factors such as energy efficiency, especially, an integrated process is necessary be-
environmental friendliness, adaptability and efficient cause of their scale and the fact that green design af-
use of resources. fects so many different elements of a building, such
As a result of population growth and increasing as day lighting, which in turn concerns sitting, orien-
standard of living, energy consumption around the tation, building form, facade design, floor to-floor
world is steadily increasing. The built environment heights, interior finishes, electric lighting controls,
has been recognized as the largest contributor for the and cooling loads, among other things. Green or
climate change. Globally, 50% of all energy usage vegetated roofs, with their impact on storm water
and more than 50% of all climate change emissions runoff, building structure, building form, thermal in-
46
Electronic Journal of Structural Engineering 13(1) 2013
sulation, and plantings, are another example where Further it was shown that the steel framed build-
integration must be considered (Malin, 2006). ing has 68% more embodied green house gas emis-
Environmental factors can contribute significantly sion as compared to the concrete framed building.
to the sustainability of a tall building. Using the mid- The operational energy was calculated using the
level floor of Burj Khalifa as an example, the total TRANSYS 16 simulating software which is a com-
amount of cooling load reduction at the summer plete and extensible simulation environment for the
peak design hour can be as much as 11% (Leung and transient simulation of systems, including multi-zone
Weismantle, 2008) buildings to validate energy requirements and con-
The buildings are one of the largest energy con- cepts.
sumers in any industrialised country and the com- The operational energy over a period of one year
mercial buildings carry a significant share. The con- simulation clearly indicate that for Melbourne
struction and operation of buildings requires energy, weather the cooling load is very much lower and ma-
and the production of that energy emits greenhouse jority of energy used is for heating purposes. There
gases (GHG). While there has been much research was no significant difference in operational energy
into the possibilities of reducing operational energy between the steel and concrete framed structure. The
consumption, there has been very little investigation total operational energy heating and cooling ob-
into reducing the whole life cycle energy required for served was 69.3 and 68.8 kWh/m2/yr for concrete
the buildings. and steel respectively (Figure 14).
A study was conducted at Universuty of Mel-
bourne to quantify and compare the embodied ener-
gy, operational energy and green house gas emission
of concrete and steel framed options, which are
commonly used in commercial buildings. A typical
high rise office building in Melbourne has been cho-
sen for this exercise. The studied building is a 50
storey with a flat roof and the total net-lettable area
of 75,570 square meters. The embodied energy con-
tribution of the substructure, the super structure with
the structural elements namely foundation, beams,
columns roof, facades and stairs were investigated.
The foundation contributed to the highest embod- Figure 14: Operational energy distribution per floor area in
ied energy of 24.5% in case of the concrete building, kWh between concrete and steel buildings
whereas for the steel building, beams represented the
highest embodied energy of 36.9% of the total (Fig- There are many building evaluation tools that fo-
ure 13). The results also showed for a 50 year period cus on different areas of sustainable development
the operational GHG emission was significantly and are designed for different types of projects. Ex-
higher that the initial embodied GHG emission. amples are BREEAM, LEED, GREEN STAR and
Home Grown (developed to be suitable for local
conditions) rating tools such as Malaysian GBI In-
dex, Singapore’s Green Mark system and Sri
Lanka’s Green Rating System for Built Environment
(GRSBE).
The categories available in LEED and GREEN
STAR –AUS can be grouped in broad form as be-
low:
emissions
Figure 13: The Embodied Energy distribution between concrete
and steel buildings es
47
Electronic Journal of Structural Engineering 13(1) 2013
48
Electronic Journal of Structural Engineering 13(1) 2013
49