ACCESSORIES GAS SIDE

NITROGEN CHARGING UNIT


TYPE SLG 1.1

OSP 761

Nitrogen Charging unit SLG 1.1


Description Optional
Customary nitrogen cylinder have a pressure of 200 bar.
Hydropneu-matic accumulators with a pre-charge pressure • Tester pressurizer OLAER type VG U see OSP 746
>200 bar can no longer be filled out of cylinders. At pre-
charge pressurers between 100 and 150 bar the nitrogen Technical data
cylinders are under-utilized.
• Flow rate 3 l/min
The OLAER nitrogen charging unit allows a better utilization • Power 1,5 kW
of the nitrogen cylinders and a charging of the accumulators • Voltage 230 V - 1 - 50 Hz
up to 380 bar. • Current consumption 10 A
• Min. inlet pressure N2 35 bar
The nitrogen charging unit runs self-acting, until the • Max. outlet pressure N2 380 bar
pre-charge pressure contact manometer, which is • Weight incl. oil contents 76 kg
adjusted on the pressure switch, is reached.
Connections
Composition
• Electric power supply cable 5m, 3-pole with plug
• Integrated hydraulic assembly type 12
• Pressure switch • Filling hose 2,5m to connect nitrogen cylinder W24,
• Electric control with access cable W32
• Pressure intensifier • Filling hose 5,0m to connect tester pressurizer
• Filling hoses OLAER type VG U

VG U optional

Manufacturer's tolerances not taken into account. The right to make modifications reserved.
Outline drawing

Schema

OLAER (Schweiz) AG, Bonnstrasse 3, CH – 3186 Düdingen, Tel 026 492 70 00, Fax 026 492 70 70, info@olaerschweiz.ch, www.olaer.ch 23.05.2016