ARYG 54 LHT
13,40 kW
16,00 kW
Specification
System Data
Power Source V/Ø/Hz 230/1/50
Moisture Removal I/h 2,5
Piping Connections (Small / Large) mm 9,52/15,88
Max Pipe Length m 50
Height Difference m 30
Refrigerant R410A
Duct types
ARYG 36 LML
9,40 kW
11,20 kW
Specification
System Data
Power Source V/ Ø/Hz 230/1/50
Moisture Removal I/h 3,0
Piping Connections (Small / Large) mm 9,52/15,88
Height Difference m 50
Max Pipe Length(Chargeless) m 30
Refrigerant R410A
B
Low Static Pressure Duct
ARG18A(HT)
5.40-5.30 kW
Compact design
Specifications
Indoor Unit ARG18A(HT)
Model No.
Outdoor Unit AOGA18A(HT)
Capacity Class BTU/h 18,000
Input Power V/φ/Hz 240-220/1/50
Cooling 18,400-18,100
BTU/h
Capacity Heating -
Cooling kW 5.30-5.30
Heating -
Cooling 2.00-1.90
Power Consumption kW
Heating -
Cooling 2.70-2.79
EER kW/kW
Heating -
Cooling 8.9-9.0
Running Current A
Heating -
Pints/h 3.5
Moisture Removal
Liter/h (1.6)
C.F.M 565
Room Air Circulation (High)
(m³/h) (960)
H / W / D (mm) 217 × 953 × 595
Indoor Unit Dimensions Weight
kg(lbs) 25.0 (55)
H / W / D (mm) 650 × 730 × 320
Outdoor Unit Dimensions Weight
kg(lbs) 46.0 (92.0)
Refrigerant R22
Connection Method Flare
Related Links
Download
Partner
Partner : Distributor
Duct Type Air Conditioner
INTRODUCTION
Cooltech's ducted-spit units are designed for duct type air
conditioning system in commercial and industrial
application. ducted-split unit has single and multiple
hermetic compressors within dependent refrigerant
circuit. Each refrigerant circuit consists of a high
efficiency condenser and expansion valve.
HEAT EXCHANGER
Each coil consist of staggered row of 3/8" OD steamless copper
tubes, mechanically expanded into die-formed aluminum fins.
each coil provided with integral sub-cooling circuit to maximize
energy efficiency and promote superior match-system operating
performance when connected to suitably sized DX Evaporator-
Blower unit. Coils are leak and pressure tested to 450 psigs while
storage pressure is keep at 100 psigs.
SAFETY CONTROLS
All outdoor units are equipped with auto reset high and low pressure cut-out to protect against
compressor damage due to high head pressure and system leakage respectively. Phase protector
(optional) is used to detect for any wrong phase and phase loss during installation and operation.
REFRIGERANT CONTROL
INDOOR CAPILLARY TUBE / ACCURATOR INDOOR TXV
TYPE
EXTERNAL STATIC
Pa in (wg) 100 (0.4)
PRESSURE
REFRIGERANT CONTROL
INDOOR TXV
TYPE
AIR FLOW CMM (CFM) 108 (3800) 127 (4500) 170 (6000) 218 (7700) 263 (9300)
EXTERNAL STATIC
Pa in (wg) 150 (0.6) 200 (0.8)
PRESSURE
REFRIGERANT CONTROL
INDOOR TXV
TYPE
AIR FLOW CMM (CFM) 312 (11000) 413 (14600) 581 (20500) 651 (23000)
EXTERNAL STATIC
Pa in (wg) 200 (0.8) 250 (1.0) 300 (1.2) 350 (1.4)
PRESSURE
PRODUCTS
AIR CONDITIONER
o SPLIT TYPE
o FLOOR STAND TYPE
o DUCT TYPE