COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Number /
Type
Wire Material Dia. Material Dia. Material Dia. Material Dia. Material
Diameter
No./mm - mm - mm - mm - mm -
1.5C-2V X 1C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
1.5C-2V X 4C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 8.5 PVC
1.5C-2V X 8C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 11.1 PVC
1.5C-2V X 21C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 17.1 PVC
2.5C-2V X 1C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Ann. Bare Cu 4.0 PVC - PVC
2.5C-2V X 4C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Ann. Bare Cu 4.0 PVC 11.2 PVC
2.5C-2V X 8C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Ann. Bare Cu 4.0 PVC 14.7 PVC
2.5C-2V X 21C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Ann. Bare Cu 4.0 PVC 22.9 PVC
2.5C-2W X 1C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Double Shield Cu. 4.6 PVC - PVC
2.5C-2W X 4C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Double Shield Cu. 4.6 PVC 12.6 PVC
2.5C-2W X 8C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Double Shield Cu. 4.6 PVC 16.7 PVC
2.5C-2W X 21C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.12 Double Shield Cu. 4.6 PVC 26.1 PVC
3C-2V X 1C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Ann. Bare Cu 5.4 PVC - PVC
3C-2V X 4C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Ann. Bare Cu 5.4 PVC 14.5 PVC
3C-2V X 8C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Ann. Bare Cu 5.4 PVC 19.3 PVC
3C-2V X 21C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Ann. Bare Cu 5.4 PVC 30.3 PVC
3C-2W X 1C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Double Shield Cu. 6.5 PVC - PVC
3C-2W X 4C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Double Shield Cu. 6.5 PVC 17.2 PVC
3C-2W X 8C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Double Shield Cu. 6.5 PVC 23.0 PVC
3C-2W X 21C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Double Shield Cu. 6.5 PVC 36.2 PVC
3C-2T X 1C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Triple Shield Cu. 7.4 PVC - PVC
3C-2T X 4C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Triple Shield Cu. 7.4 PVC 19.4 PVC
3C-2T X 8C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Triple Shield Cu. 7.4 PVC 26.0 PVC
3C-2T X 21C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.12 Triple Shield Cu. 7.4 PVC 41.0 PVC
5C-2V X 1C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Ann. Bare Cu 7.4 PVC - PVC
5C-2V X 4C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Ann. Bare Cu 7.4 PVC 19.4 PVC
5C-2V X 8C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Ann. Bare Cu 7.4 PVC 26.0 PVC
5C-2V X 21C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Ann. Bare Cu 7.4 PVC 41.0 PVC
5C-2W X 1C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Double Shield Cu. 8.3 PVC - PVC
5C-2W X 4C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Double Shield Cu. 8.3 PVC 21.5 PVC
5C-2W X 8C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Double Shield Cu. 8.3 PVC 28.9 PVC
5C-2W X 21C 1 / 0.80 Ann. Bare Cu 4.9 PE 0.14 Double Shield Cu. 8.3 PVC 45.7 PVC
7C-2V X 1C 1 / 1.20 Ann. Bare Cu 7.6 PE 0.18 Ann. Bare Cu 10.5 PVC - PVC
7C-2V X 4C 1 / 1.20 Ann. Bare Cu 7.6 PE 0.18 Ann. Bare Cu 10.5 PVC 26.8 PVC
7C-2V X 8C 1 / 1.20 Ann. Bare Cu 7.6 PE 0.18 Ann. Bare Cu 10.5 PVC 36.2 PVC
7C-2V X 21C 1 / 1.20 Ann. Bare Cu 7.6 PE 0.18 Ann. Bare Cu 10.5 PVC 57.4 PVC
10C-2V X 1C 1 / 1.40 Ann. Bare Cu 9.0 PE 0.20 Ann. Bare Cu 11.7 PVC - PVC
10C-2V X 4C 1 / 1.40 Ann. Bare Cu 9.0 PE 0.20 Ann. Bare Cu 11.7 PVC 29.7 PVC
10C-2V X 8C 1 / 1.40 Ann. Bare Cu 9.0 PE 0.20 Ann. Bare Cu 11.7 PVC 40.2 PVC
10C-2V X 21C 1 / 1.40 Ann. Bare Cu 9.0 PE 0.20 Ann. Bare Cu 11.7 PVC 63.8 PVC
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate
the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product
specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Electrical Characteristics
Characteristics
Conductor Insulation
No. Type Capacitance
Resistance Resistance
o
pF / m Ω (20 C) MΩ.km
1 1.5C - 2T 69 968 1000
4 3C - 2V 67 91.4 1000
5 3C - 2W 67 91.4 1000
6 3C - 2T 67 91.4 1000
7 5C - 2V 67 35.9 1000
8 5C - 2W 67 35.9 1000
9 7C - 2V 67 15.24 1000
10 10C - 2V 67 11.2 1000
Test Voltage
V / Min. 1000
(A.C)
Impedance W 75
Velocity of
% 67
Propagation
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate
the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product
specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Type Number /
Wire Material Dia. Material Dia. Material Dia. Material Dia. Material
Diameter
No./mm - mm - mm - mm - mm -
Double Shield
BT3002 X 1C 1 / 0.31 Ann. Bare Cu 1.85 PE 0.10 3.55 PVC - PVC
Tinned Cu.
Double Shield
BT3002 X 4C 1 / 0.31 Ann. Bare Cu 1.85 PE 0.10 3.55 PVC 10.1 PVC
Tinned Cu.
Double Shield
BT3002 X 8C 1 / 0.31 Ann. Bare Cu 1.85 PE 0.10 3.55 PVC 13.2 PVC
Tinned Cu.
Double Shield
BT3002 X 21C 1 / 0.31 Ann. Bare Cu 1.85 PE 0.10 3.55 PVC 20.5 PVC
Tinned Cu.
Double
BT2003 X 1C 1 / 0.61 Ann. Bare Cu 3.60 PE 0.15 6.70 PVC - PVC
Shield Cu.
Double
BT2003 X 4C 1 / 0.61 Ann. Bare Cu 3.60 PE 0.15 6.70 PVC 17.7 PVC
Shield Cu.
Double
BT2003 X 8C 1 / 0.61 Ann. Bare Cu 3.60 PE 0.15 6.70 PVC 23.6 PVC
Shield Cu.
Double
BT2003 X 21C 1 / 0.61 Ann. Bare Cu 3.60 PE 0.15 6.70 PVC 37.2 PVC
Shield Cu.
Electrical Characteristics
Characteristics Test Items Unit Values
Conduct
or Insulation Test Voltage
No. Type Capacitance V / Min. 1000
Resistanc Resistance (A.C)
e
pF / m W (20oC) MW.km Impedance W 75
1 BT3002 66 230 20
2 BT3003 6.58 61 20
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Type Number /
Wire Material Dia. Material Dia. Material Dia. Material Dia. Material
Diameter
No./mm - mm - mm - mm - mm -
Opp/Al +
SC05/3.1FSA 1 / 0.50 Tinned Ann. Cu. 3.10 PE Foam 0.12 Tinned Cu. 5.54 PVC - PVC
Braiding
Opp/Al +
SC05/3.1FSA 1 / 0.50 Tinned Ann. Cu. 3.10 PE Foam 0.12 Tinned Cu. 15 PVC 15.0 PVC
Braiding
Opp/Al +
SC05/3.1FSA 1 / 0.50 Tinned Ann. Cu. 3.10 PE Foam 0.12 Tinned Cu. 20.2 PVC 20.2 PVC
Braiding
Opp/Al +
SC05/3.1FSA 1 / 0.50 Tinned Ann. Cu. 3.10 PE Foam 0.12 Tinned Cu. 31.5 PVC 31.5 PVC
Braiding
Electrical Characteristics
Characteristics
Insulation
No. Type Capacitance Conductor Resistance
Resistance
pF / m Ω (20oC) MΩ.km
1 SC05/3.1FSA 56 37.1 1000
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Type Number /
Dia.
Wire Material Dia. Material Dia. Material Dia. (Nom.) Material
(App.)
Diameter
No./mm - mm - mm - mm mm -
Al Foil + Ann.
ST212 X 1C 1 / 0.40 Tinned Cu. 1.90 PE Foam 0.10 3.13 - PVC
Cu.
Al Foil + Ann.
ST212 X 4C 1 / 0.40 Tinned Cu. 1.90 PE Foam 0.10 3.13 9.08 PVC
Cu.
Al Foil + Ann.
ST212 X 8C 1 / 0.40 Tinned Cu. 1.90 PE Foam 0.10 3.13 11.86 PVC
Cu.
Al Foil + Ann.
ST212 X 21C 1 / 0.40 Tinned Cu. 1.90 PE Foam 0.10 3.13 18.32 PVC
Cu.
Double Shield
ST212 X 1C 1 / 0.81 Tinned Cu. 3.71 PE Foam 0.10 5.73 - PVC
Cu. + Al Foil
Double Shield
ST212 X 4C 1 / 0.81 Tinned Cu. 3.71 PE Foam 0.10 5.73 15.35 PVC
Cu. + Al Foil
Double Shield
ST212 X 8C 1 / 0.81 Tinned Cu. 3.71 PE Foam 0.10 5.73 19.22 PVC
Cu. + Al Foil
Double Shield
ST212 X 21C 1 / 0.81 Tinned Cu. 3.71 PE Foam 0.10 5.73 31.92 PVC
Cu. + Al Foil
Electrical Characteristics
Characteristics
Conductor Insulation
No. Type Capacitance
Resistance Resistance
pF / m Ω (20oC) MΩ.km
1 ST212 76 145 1000
2 ST214 76 37 1000
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Type Number /
Wire Material Dia. Material Dia. Material Dia. Material Dia. Material
Diameter
No./mm - mm - mm - mm - mm -
Ann. Bare Single
TZC-N X 1C 1 / 0.31 1.95 PE 0.10 4.00 PVC - PVC
Cu. Shield Cu.
Ann. Bare Single
TZC-N X 4C 1 / 0.31 1.95 PE 0.10 4.00 PVC 11.2 PVC
Cu. Shield Cu.
Ann. Bare Single
TZC-N X 8C 1 / 0.31 1.95 PE 0.10 4.00 PVC 14.7 PVC
Cu. Shield Cu.
Ann. Bare Single
TZC-N X 21C 1 / 0.31 1.95 PE 0.10 4.00 PVC 22.9 PVC
Cu. Shield Cu.
Electrical Characteristics
Characteristics
pF / m Ω (20oC) MΩ.km Ω
1 TZ-N 66 230 1000 75
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) JACKET
Number /
Type
Wire Material Diameter Material Coverage Material Dia. Material
Diameter
No./mm - mm - % - mm -
Al Foil + Tinned
RG-6/U 1 / 1.020 Ann. Bare Cu. 4.57 FPE 75 6.9 PVC
Ann. Cu.
RG-8/U 1 / 0.900 Ann. Bare Cu. 7.24 FPE 95 Ann. Bare Cu. 10.3 PVC
RG-8/U 7 / 0.724 Ann. Bare Cu. 7.24 PE 95 Ann. Bare Cu. 10.3 PVC
RG-11/U 7 / 0.404 Tinned Cu. 7.24 PE 95 Ann. Bare Cu. 10.3 PVC
RG-34/U 7 / 0.724 Ann. Bare Cu. 11.6 PE 95 Ann. Bare Cu. 15.9 PVC
RG-34/U 7 / 0.632 Ann. Bare Cu. 11.7 PE 95 Ann. Bare Cu. 16.0 PVC
RG-58/U 1 / 0.800 Ann. Bare Cu. 2.90 PE 95 Tinned Cu. 5.00 PVC
Al Foil + Tinned
RG-58A/U 19 / 0.203 Tinned Cu. 2.90 FPE 97 5.03 PVC
Cu.
RG-59/U 1 / 0.643 Ann. Cu. 3.71 pe 95 Ann. Bare Cu. 6.15 PVC
RG-59/U 7 / 0.254 Ann. Bare Cu. 3.71 FPE 95 Ann. Bare Cu. 6.15 PVC
RG-59/U 1 / 0.810 Ann. Bare Cu. 3.71 FPE 95 Ann. Bare Cu. 6.15 PVC
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Construction Data
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) JACKET
Number /
Type
Wire Material Diameter Material Coverage Material Dia. Material
Diameter
No./mm - mm - % - mm -
RG-59B/U 1 / 0.584 Ann. Bare Cu. 3.71 PE 95 Ann. Bare Cu. 6.15 PVC
RG-213/U 7 / 0.752 Ann. Bare Cu. 7.24 PE 95 Ann. Bare Cu. 10.3 PVC
RG-216/U 7 / 0.404 Tinned Cu. 7.24 PE 97 Double Shield Cu. 10.8 PVC
RG-217/U 1 / 2.692 Ann. Bare Cu. 9.40 PE 97 Double Shield Cu. 13.8 PVC
Construction Data
Characteristics
pF / m Ω %
1 RG-6/U 55 75 83
2 RG-8/U 85 52 84
3 RG-8/U 97 52 67
4 RG-11/U 57 75 83
5 RG-11/U 67 75 67
6 RG-29/U 94 53.5 67
7 RG-34/U 71 71 67
8 RG-34/U 67 75 67
9 RG-58/U 94 50 67
10 RG-58A/u 86 51 83
11 RG-58A/u 102 52 67
12 RG-59/U 69 73 67
13 RG-59/U 57 75 83
14 RG-59/U 57 76 83
15 RG-59B/U 67 77 67
16 RG-213/U 98 50 67
17 RG-216/U 67 75 67
18 RG-217/U 98 50 67
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
Cable Constructions :-
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
COAXIAL CABLE SOUTHERN CABLE
CONSTRUCTION
CONDUCTOR INSULATION SHIELD (BRAIDING) SHEATH JACKET
Type Number /
Material Dia. Material Dia. Material Dia. Material Dia. Material
Wire Diameter
No. / mm - mm - mm - mm - mm -
1.5C-2V X 1C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
1.5C-2V X 4C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 8.5 PVC
1.5C-2V X 8C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 11.1 PVC
1.5C-2V X 21C 1 / 0.26 Ann. Bare Cu 1.6 PE 0.10 Ann. Bare Cu 2.9 PVC 17.1 PVC
2.5C-2V X 1C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
2.5C-2V X 4C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 11.2 PVC
2.5C-2V X 8C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 14.7 PVC
2.5C-2V X 21C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 22.9 PVC
2.5C-2W X 1C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
2.5C-2W X 4C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 12.6 PVC
2.5C-2W X 8C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 16.7 PVC
2.5C-2W X 21C 1 / 0.40 Ann. Bare Cu 2.4 PE 0.10 Ann. Bare Cu 2.9 PVC 26.1 PVC
3C-2V X 1C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
3C-2V X 4C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 14.5 PVC
3C-2V X 8C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 19.3 PVC
3C-2V X 21C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 30.3 PVC
3C-2W X 1C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC - PVC
3C-2W X 4C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 17.2 PVC
3C-2W X 8C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 23.0 PVC
3C-2W X 21C 1 / 0.50 Ann. Bare Cu 3.1 PE 0.10 Ann. Bare Cu 2.9 PVC 36.2 PVC
CHARACTERISTIC
Conductor Insulation
No. Type Capacitance
Resistance Resistance
pF / m Ω (20ºC) M Ω - Km
1 1.5C - 2T 69 968 1000
2 2.5C - 2V 69 145 1000
3 2.5C - 2W 69 145 1000
4 3C - 2V 67 91.4 1000
5 3C - 2W 67 91.4 1000
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.