You are on page 1of 1

SEE TRENCH PLAN

L
SEE TRENCH PLAN SEE TRENCH PLAN SEE TRENCH PLAN
REINFORCEMENT(B)
REINFORCEMENT(B)

STRAP BEAM REINFORCEMENT T/B

C1 C1

B
C1 C1

COL

B
L

TYPICAL COMBINE FOOTING DETAILS


STRAP FOOTING PLAN L

COLUMN COLUMN

COLUMN COLUMN

1500 (MIN. DEPTH OF FOOTING


1500 (MIN. DEPTH OF FOOTING

FROM ORIGINAL G.L.)


FROM ORIGINAL G.L.)
STRAP BEAM

D
TYPICAL COMBINED FOOTING SECTION AT C1

4"
8mmØ@6"c/c both way

3"
4"

1"

1"
STRAP FOOTING (STB) SECTION AT C1
2mm thick folded MS plate
SLAB Details
MS framing
FOUNDATION DETAILS

4"
CONCRETE GRADE: M20 REINFORCING STEEL : Fe 500 Bearing capacity of soil=100kN/m2(Assumed)
SIZE OF FOOTING DEPTH OF FOOTING Footing Reinforcement Remarks
S.No. TYPE TYPICAL FLOOR SLAB Details
LENGTH BREADTH At Edge (d) At Centre (D') Along X- direction Along Y-direction
1. 9'-0" 9'-0" 8" 6" Ground Floor Footing
F1 16Ø@5" c/c 16Ø@5" c/c TIE BEAM 2
2. F2 8'-0" 8'-0" 8" 6" 16Ø@5" c/c 16Ø@5" c/c Ground Floor Footing

3. F3 7'-0" 7'-0" 6" 16Ø@5" c/c 16Ø@5" c/c


6" Ground Floor Footing
COLUMN TIE RODS 1
4. F4 5'-0" 5'-0" 6" 6" 16Ø@5" c/c 16Ø@5" c/c Ground Floor Footing

5. CF1 12'-4" 8'-0" COLUMN


8" 6" 16Ø@5" c/c 16Ø@5" c/c Ground Floor Footing
GROUND LEVEL COLUMN MAIN RODS
7
6. CF2 9'-8" 5'-0" 8" 6" 16Ø@5" c/c 16Ø@5" c/c Ground Floor Footing

18'-5" 5'-0"
6
7. STF1 6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing

8. STF2 13'-7" 5'-0"


8
6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing
FOUNDATION BEAM 3
9. STF3 16'-2" 5'-0" 6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing

10. STF4 13'-5" 5'-0" 6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing
4
11. STF5 13'-11" 5'-0" 6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing
5
4" 4" Longitudinal Reinforcement
12"
12. STF6 12'-1" 5'-0"

5ft.
6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing

13. STF7 10'-9" 5'-0" Transverse Reinforcement


6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing

D'
ld 6"(min)

D
14. STF8 8'-5" 5'-0" 6" 6" 12Ø@5" c/c 12Ø@5" c/c Ground Floor Footing

3" d
SECTION Y-Y
75mm THICK. M10 P.C.C. 9
ONE LAYER FLAT BRICK SOLING
12 mm Ø @ 6" C/C

Y
1'-8" COMPACTED EARTH
B/2

3
B
4" 1' 4" 2

90
TYPICAL SECTION AT X

300MM
4"

120
X X

90
1'-8"

B
1'

300MM
4"

Y
B/2

12 mm Ø @ 6" C/C FLOOR COLUMN C1 COLUMN C2

L/2 L L/2
GROUND
TYPICAL FOOTING F1 PLAN

90
FLOOR

300MM
120
90
300MM

VARIES
9"
ISNB300
TIE BEAM
B
6#16Ø 3#16Ø 3#16Ø FIRST

90
12"

TIE BEAM
1'

300MM
120
FLOOR

90
1'

300
300MM
(As per site condition)

3#16Ø
B ISNB 300
230 7
VARIES

3#16Ø
SECTION A-A
OWNER:-
230 SIGNATURE:-
A 3#16Ø
VARIES

3#16Ø
GROUND LEVEL 3 BLD. TYPE:- LOCATION:-
BANQUET BASUNDHARA
1'

4
300

PLOT NO:- AREA:-


A
FOUNDATION 3'-11"
3#16Ø
3'-11" 5
BEAM 230 DESIGN BY:- DRAWN BY:-
6#16Ø 3#16Ø AR. SHAILENDRA BC LOKENDRA BC
1'

8Ø -4"/6"c/c 8Ø@100c/c 8Ø@150c/c 8Ø@100c/c SECTION B-B

3"mm PCC CHECKED BY:- REGD NO:- SIGNATURE:-

ONE LAYER FLAT TYPICAL FOUNDATION & TIE BEAM SECTION


BRICK SOLING DRAWING. TITLE:-

FOUNDATION & TIE BEAM DETAILS


SECTION X-X STRUCTURAL DETAILS

DATE:- SCALE:-
NOV, 2017 1
8"=1'-0"
SHEET NO. STR/6

You might also like