Planning a Successful Data Center Move or Relocation
RESOURCES
By Industry Planning a move of any sort can cause significant stress and anxiety
for anyone. Planning for a data center move or relocation, however,
By Application has the added pressure of potential disruptions to critical business
operations and/or data losses that can severely damage an
Data Center organization's overall business and reputation.
DCIM Many organizations have recently encountered the possibility of a
Smart Solutions data center move or relocation. The key business factors driving the
decision to go forward with such a large-scale and expensive
Data Center investment (estimates range from $300 - $400 per foot to move
Insights existing equipment and $750 - $1,000 per foot to implement new
equipment) as a data center move or relocation include:
Infrastructure
Management Need to upgrade data center facilities
Need to identify cheaper data center facilities
Enterprise
Requirements for redundancy -- business continuity
Strategies Aperture Flash Tour
improvements
Capacity Physical data center consolidations as a result of mergers Resource Library
Management and acquisitions
in the Data Also visit the
Center Once the business decision to invest the necessary resources for a
data center move or relocation is made, it is critical to follow a Aperture Research
Data Center detailed and integrated roadmap to ensure a successful Institute
Consolidation implementation. As Gartner states, a data center move or relocation
plan requires diligent and seamless integration between the data Emerson Resources
Data Center center facilities plan and the IS organization plan, and ensuring
Monitoring Infrastructure
coordinated project management and execution. Most difficulties (in
Management
Data Center data center moves and relocations) can be traced to a breakdown
Operations: between two major functional components -- IS requirements and Portfolio
The Last data center facilities location and design specifications. For Data Center and
Domain for IT example, miscalculations in locations, equipment densities, power Networking
Operational and heating and HVAC capacities can severely damage IT Services
Efficiency operations and service availability.
Data Center The following guidelines relate to the most critical phases of a data
Power and center move or relocation project and are applicable for smaller data
Cooling: New centers (3,000 to 5,000 square feet of raised floor space) as well as
Requirements large facilities of more than 10,000 square feet of raised floor space.
for a New
Generation of Step 1: Form a multi-disciplinary project team with key advisors.
Computing The multi-disciplinary team should include members from IT
operations, applications, data network operations, facilities and real
Facilities estate specialists and human resources. The team will require a
Management dedicated project manager, who is closely aligned with the IT
in the Data organization, to lead and coordinate all activities during the planning
Center phase, through the implementation of the data move or relocation
and during the post-move occupancy to ensure newly defined
Planning a processes and procedures will continue to be utilized going forward.
Successful Key stakeholders should be recruited early on as advisors for the
Data Center data center move or relocation project to ensure buy-in throughout
Move or the organization.
Relocation
http://www.emersonnetworkpower.com/en-US/Solutions/ByApplication/DataCenterNetworking/Enterprise-Strategies/Pages/aperture-enterprise-planning-a-… 1/3
30/7/2014 Planning a Successful Data Center Move or Relocation
Step 2: Create a business case that highlights the business
The Green rationale and technical "do-ability".
Data Center The business case should highlight the critical success factors of
Movement - the data center move or relocation project as well as help the team
Improving and organization understand the potential obstacles that lay ahead.
Energy This step in the project helps the team prioritize key issues and
Efficiency manage expectations for the team and the rest of the organization.
Step 5: Create a detailed space layout and design for the new data
center facility.
Review the desired state for the new data center with regards to
functionality, technical and financial considerations and any new
process improvements that must be made. The space layout and
design should include all engineering and space aspects for the
new data center including the logical and physical (spatial)
environment, the critical operations infrastructure (power, cooling,
network connectivity) and future growth considerations. Utilizing
visual databases and maps to develop the rack layout and to
determine the optimal electrical and air cooling distribution systems
is highly recommended.
http://www.emersonnetworkpower.com/en-US/Solutions/ByApplication/DataCenterNetworking/Enterprise-Strategies/Pages/aperture-enterprise-planning-a-… 2/3
30/7/2014 Planning a Successful Data Center Move or Relocation
Success of data center move and relocation projects are highly
dependent upon detailed and coordinated planning and execution of
many functional participants. By taking the time to think through all
possible scenarios and how they will be addressed and by
understanding the intricacies and interdependencies that exist for
data center move/relocation projects, companies can avoid the risks
of budget overruns, missed schedules and serious business
disruptions and enable a successful relocation, Learn More.