2. 6" BB to BP-1 Site Survey Pig Launcher and Pig Receiver Some spots of Pig Launcher and Pig No major or minor finding,
on BB Platform and BP-1 Platform Receiver (Coating) was rusty fit for service
CP reading and sea water resistant Result of CP Reading Measurement
measurement on riser still good condition (more negative
UT Thickness measurement on accessible than -800 mV)
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
3. 10" LP Oil Line HGA to CPA Site Survey Pig Launcher and Pig Receiver Pig Launcher and Pig Receiver are The pipe riser at RC #39 M2
on HGA Platform and CPA portable side unprotected by CP
CP reading and sea water resistant Result of CP Reading Measurement
measurement on riser at RC #39 M2 side between -747
UT Thickness measurement on accessible mV until -754 mV
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
4. 12" LP Oil Line HA to M2 Site Survey Pig Launcher and Pig Receiver Pig Launcher and Pig Receiver are The pipe riser at RC #39 M2
on HA Platform and M2bis Platform portable side unprotected by CP and
CP reading and sea water resistant Result of CP Reading Measurement anode cable was
measurement on riser at RC #39 M1 side between -653 disconnected
UT Thickness measurement on accessible mV until -681 mV
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
5. 12" LP Oil Line HV to CPA Site Survey Pig Launcher and Pig Receiver Pig Launcher and Pig Receiver are The pipe riser at RC #39 M2
on HV Platform and CPA portable side unprotected by CP
CP reading and sea water resistant Result of CP Reading Measurement
measurement on riser at RC #39 M2 side between -757
UT Thickness measurement on accessible mV until -781 mV
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
6. 12" LP Oil Line HX to M2 Site survey line pipe on HX Platform and Good Condition on Line Pipe and The pipe riser at RC #39 M2
M2bis Platform Riser side unprotected by CP and
CP reading and sea water resistant Result of CP Reading Measurement anode cable was
measurement on riser at RC #39 M2 side between -733 mV disconnected
UT Thickness measurement on accessible until -736 mV
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
7. 12" LP Oil Line HZA to HJ Site survey line pipe on HZA Platform and Good Condition on Line Pipe No major or minor finding,
HJ Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
8. 12" MP Gas Line M1 to M2 Site Survey Pig Launcher and Pig Receiver Pig Launcher and Pig Receiver are The pipe riser at RC #39
on M1 Platform and M2 Platform portable unprotected by CP
CP reading and sea water resistant Result of CP Reading Measurement
measurement on riser at RC #39 M2 side -759 mV until -792
UT Thickness measurement on accessible mV
straight pipe and elbow Result of UT Measurement is
Visual Inspection of pipeline safety device acceptable (minimum actual
thickness above thickness required)
Good condition on Safety device
9. 4" HP Gas Line HJ to HZA Site survey line pipe on HJ Platform and Good Condition on Line Pipe The pipe riser at RC #36
HZA Platform Result of CP Reading Measurement Well Side unprotected by CP
CP reading and sea water resistant at RC #36 between -683 mV until -
measurement on riser 894 mV
UT Thickness measurement on accessible Result of UT Measurement is
straight pipe and elbow acceptable (minimum actual
Visual Inspection of pipeline safety device thickness above thickness required)
Good condition on Safety device
10. 4" HP Gas Line HK to HKA Site survey line pipe on HK Platform and Good Condition on Line Pipe No major or minor finding,
HKA Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
11. 4" HP Gas Line HP to HPA Site survey line pipe on HP Platform and Good Condition on Line Pipe No major or minor finding,
HPA Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
12. 6" HP Gas Line HDA to HAA Site survey line pipe on HDA Platform and Good Condition on Line Pipe No major or minor finding,
HAA Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
13. 6" MP Oil Line HGA to M1 Site survey line pipe on HGA Platform and Good Condition on Line Pipe No major or minor finding,
M1 Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
14. 6" MP Oil Line HK to M1 Site survey line pipe on HK Platform and Good Condition on Line Pipe No major or minor finding,
M1 Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
15. 6" MP Oil Line HKA to HK Site survey line pipe on HKA Platform and Good Condition on Line Pipe No major or minor finding,
HK Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
16. 6" MP Oil Line HRB to HH Site survey line pipe on HRB Platform and Good Condition on Line Pipe No major or minor finding,
HH Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
17. 6" HP Gas Line M1 to HK Site survey line pipe on M1 Platform and Good Condition on Line Pipe No major or minor finding,
HK Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
18. 8" LP Oil Line HK to M1 Site survey line pipe on HK Platform and Good Condition on Line Pipe No major or minor finding,
M1 Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
19. 6" HP Gas Line HYB to HYA Site survey line pipe on HYB Platform and Good Condition on Line Pipe No major or minor finding,
HYA Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
20. 6" LP Oil Line HKA to HK Site survey line pipe on HKA Platform and Good Condition on Line Pipe No major or minor finding,
HK Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
21. 6" MP Oil Line HC to CPA Site survey line pipe on HC Platform and Good Condition on Line Pipe No major or minor finding,
CPA Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
22. 6" TM-11/TM-53 to GTS-1 Site survey line pipe on TM-11/TM-53 Good Condition on Line Pipe No painting on line pipe at
Platform and GTS-1 Platform Result of UT Measurement is aerial section (Minor)
UT Thickness measurement on accessible acceptable (minimum actual Recommendation :
straight pipe and elbow thickness above thickness required) repainting of line pipe to
Visual Inspection of pipeline Good condition on Safety device prevent the corrosion
safety device
PT. RADIANT UTAMA INTERINSCO, TBK
23. 6" TM-57/TM-77/TM-83 to GTS-1 Site survey line pipe on TM-57/TM- Good Condition on Line Pipe The riser pipe at RC #36
77/TM-83 Platform and GTS-1 Platform Result of CP Reading Measurement unprotected by CP
CP reading and sea water resistant at RC #36 between -624 mV until - No painting on line pipe at
measurement on riser 708 mV aerial section (Minor)
UT Thickness measurement on accessible Result of UT Measurement is Recommendation :
straight pipe and elbow acceptable (minimum actual repainting of line pipe to
Visual Inspection of pipeline safety device thickness above thickness required) prevent the corrosion
Good condition on Safety device
24. 6" TM-43 to GTS-1 Site survey line pipe and riser on TM- Good Condition on line pipe No painting on line pipe at
43 Platform and GTS-1 Platform Result of UT Measurement is aerial section (Minor)
UT Thickness measurement on acceptable (minimum actual Recommendation :
accessible straight pipe and elbow thickness above thickness repainting of line pipe to
Visual Inspection of pipeline safety required) prevent the corrosion
device Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
25. 8" TM-36/TM-37 to GTS-2 Site survey line pipe on TM-36/TM-37 Good Condition on line pipe Pointer of Pressure
Platform and GTS-2 Platform Result of UT Measurement is Indicator at GTS-2
UT Thickness measurement on acceptable (minimum actual Platform was broken
accessible straight pipe and elbow thickness above thickness (Minor)
Visual Inspection of pipeline safety required) Recommendation :
device Good condition on Safety device Pressure Indicator should
be repair
26. 8" TM-58/TM-82 to GTS-1 Site survey line pipe on TM-58/TM-82 Good Condition on line pipe No major or minor finding,
Platform and GTS-1 Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device
27. 12" MP Gas Line CPA to M2 Site Survey Pig Launcher and Pig Receiver Pig Launcher and Pig Receiver are No major or minor finding,
on CPA and M2 Platform portable fit for service
CP reading and sea water resistant Result of UT Measurement is
measurement on riser acceptable (minimum actual
UT Thickness measurement on accessible thickness above thickness required)
straight pipe and elbow Good condition on Safety device
Visual Inspection of pipeline safety device
28. 6" HP Gas Line HL to HLB Site survey line pipe on HL Platform and Good Condition on Line Pipe The riser pipe at RC #86
HLB Platform Result of CP Reading Measurement unprotected by CP
CP reading and sea water resistant at RC #86 between -750 mV until -
measurement on riser 760 mV
UT Thickness measurement on accessible Result of UT Measurement is
straight pipe and elbow acceptable (minimum actual
Visual Inspection of pipeline safety device thickness above thickness required)
Good condition on Safety device
PT. RADIANT UTAMA INTERINSCO, TBK
29. 6" HP Oil Line HC to HCA Site survey line pipe on HC PLatform and Good Condition on line pipe No major or minor finding,
HCA Platform Result of UT Measurement is fit for service
UT Thickness measurement on accessible acceptable (minimum actual
straight pipe and elbow thickness above thickness required)
Visual Inspection of pipeline safety device Good condition on Safety device