2) The minimum height of the station protector installation from the ground is
a) At eye level of the installer
b) 6 feet above the ground
c) 5 feet above the ground
d) 4 feet above the ground
3) For proper identification of the individual conductors of a parallel wire, a lobe is provided on one of
the conductors which is referred to
a) Tip conductor
b) Ring conductor
c) Tracer conductor
d) Letters b and c of the above
4) The drive hook installation for pole to pole wire run is to be placed
a) 4 inches above the cable or messenger
b) 4 inches below the cable or messenger
c) 6 inches above the cable or messenger
d) 6 inches below the cable or messenger
5) Technology that enables high bandwith over normal telephone copper pairs
a) ADSL
b) IDSL
c) VDSL
d) RADSL
6) For proper identification of the individual conductors of an Aerial Service wire, The blue insulator of
one of the conductors is referred to as
a) Tip conductor
b) Ring conductor
c) Strength Membrane
d) None of the above
1
7) E1 lease lines, telco transport application over one copper cable pair is for what type of DSL?
a) RADSL
b) VDSL
c) HSDSL
d) IDSL
8) To avoid occurrence of trouble due to conductor termination, there should be allowed distance
between the binding post and the insulator of the conductor a clearance of
a) ½ of an inch
b) 1/3 of an inch
c) 1/5 of an inch
d) 1/8 of an inch
9) To provide climbing space, the drive hook should not be driven at the
a) Side of the pole
b) Face (front side) of the pole
c) Back of the pole
d) Any place on the pole
10) The downward drooping of the line wire due to weight is called the
a) Sag
b) Span
c) Drop wire
d) Line wire
13) Interactive multimedia, fast internet access, remote office LAN and SOHO application is for what
type of DSL?
a) SHDSL
b) RADSL
c) VDSL
d) HSDSL
14) In installing ground rods, to avoid water pipes, electrical conduits and wall foundation, ground rods
should have______________distance from the wall
a) 2 feet
b) 3 feet
c) 6 inches
d) 12 to 18 inches
2
15) The telephone wire ran beneath the cable or messenger wire and is usually coded as “R” is called
the
a) Drop wire
b) Ground wire
c) Line wire
d) Jumper wire
17) The maximum length of AWG # 12 ground wire allowed for the installation at the station protector is
a) 14 feet
b) 2 feet
c) 6 feet
d) 20 feet
19) If you are to use an 8 feet ladder, the distance of the ladder foot from the wall or any vertical
support to work safely is
a) 1 foot
b) 2 feet
c) 3 feet
d) None of the above
20) The disadvantage of this internet connection is, it is not for residential subscriber
a) ADSL
b) HDSL
c) Cable modem
d) Analog modem
22) To avoid line wire stress in LINE wire AWG # 22 it is required to install additional support in every
a) 100 feet
b) 150 feet
c) 200 feet
d) None of the above
3
23) There are four causes of troubles in telephone conductors and to test for X , the test handset is to be
connected to
a) Battery potential source
b) Ground potential source
c) Across the pair of conductors
d) None of the above
24) It is the type of wiring that starts from the telephone protector with a single cable through the first
connecting block then run another cable from first cbk to the next cbk.
a) Cluster wiring
b) Chain wiring
c) Cluster and chain wiring
d) None of the above
25) Avoid making a sharp curve in the wire run by issuing_____ intermediate supports to every curve
a) One
b) Two
c) Three
d) Four
27) To change the direction of line wire, and to avoid private properties and any sort of obstruction, the
installer should use a
a) Ground clamp
b) Ground rod
c) PS-6 clamp
d) Span clamp
4
31) It is not a loop qualification issue
a) Loop length
b) Guage
c) Weather
d) Load coil
32) When replacing an Aerial Service Wire, the Disposition (DIS) should be:
a) 452
b) 45Z
c) 45B
d) None of the above
33) The drive hook is to be driven deep into the plow side until the hook is approximately
a) 1 inch apart from the pole
b) 2 inches away from the pole
c) 2 ½ inches from the pole
d) ½ inch away from the pole
34) Maximum number of protectors that we can utilize if we will use AWG#12 ground wire
a) 1 protector
b) 2 protectors
c) 4 protectors
d) 6 protectors
35) Blue conductors of AWG # 22 line wire should be connected to the _________ .
a) Right binding post
b) Left binding post
c) Left or right binding post
d) None of the above
37) The proper installation of conductors in the protector should be placed between
a) Binding post
b) Washers
c) Ground binding post
d) Not one of the above
38) The top of the ground rod should be at least _______the ground surface of the hard floor.
a) 12 inches above
b) 3 inches above
c) 6 inches below
d) 3 inches below
5
39) While driving a ground rod in standing position in a hard surface, you are allowed to drive ground
rod in a slanting position but should not exceed of more than
a) 45 degrees
b) 50 degrees
c) 65 degrees
d) 80 degrees
40) The maximum number of P-clamps to be attached on one drive hook should be
a) 5 P-clamps
b) 7 p- clamps
c) 8 p-clamps
d) 10 p-clamps
42) In every corner of the block wiring should be provided with two intermediate support to avoid
a) Sharp bends
b) sag
c) Change of direction
d) All of the above
45) It could be used for video services over existing phone line
a) ADSL
b) IDSL
c) HSDSL
d) VDSL
6
47) The previous advantage of this is low cost and market availability
a) Cable modem
b) HDSL
c) Analog modem
d) ADSL
48) In installing copper clad line wire, if the span reaches 150 feet, a _______is needed for additional
support.
a) Jacketted Wire
b) P-Clamp
c) Mid-Span Clamp
d) Drive Hook
49) It achieve broadband speeds over most universal network media in the world which primarily use an
ordinary phone wire
a) DSL technology
b) SDSL Technology
c) HDSL Technology
d) ADSL Technology
53) The CAS of void warranty Modem KASDA KW5819 4P (Disposition=M76) which was replaced by the
same brand and model is
a) 214
b) M76
c) V76
d) 007
7
54) NCLSP stands for:
a) New Customer & Local Services Project
b) Network & Local Support Project
c) Network & Customer Line Services Provision
d) New Customer Line Station Provisioning
58) Trouble Index (TI) is measured by the number of Fault Tickets per..
a) Number of repaired tickets in a month
b) Number of installed SO in a month
c) Number of working lines in an area
d) Number of sub-standard Installation
60) At the end of working day, this form/s should be fully filled-up and submitted by FRM Technician
a) DCWR
b) PLD 615
c) RSO
d) EASF
61) This number identifies the Installer and Technician in PLDT system
a) Access Pass
b) Technician ID
c) Fiberhome ID
d) None of the above
8
62) The Disposition of OpSim / Subs-Loop /Drop wire is:
a) 451
b) 452
c) 458
d) None of the above
64) Draw and explain the self test procedure for foreign battery (BX)
Answer:
9
65) Draw the complete subs-loop including sections and codes of each part.
Answer:
two (2) points for each correct code and meaning Total 16 points:
Total=28 points
-End-