Professional Documents
Culture Documents
TITLE
PROVISION BY CONTRACTOR.
DISTRIBUTION LIST
Tenderers
The present document is CONFIDENTIAL and it is the property of eni . It shall not be shown to third parties nor shall it be used
for reasons different from those owing to which it was given.
IDENTIFICATION CODE PAG2OF126
RIG AVAILABILITY.
DESCRIPTION UNIT CONTRACTOR'S DATA
Actual Location(Mandatory : only Rigs within Africa is required) +
Duration of actual Contract (if any) Date
Estimated Time to carry out Upgrading Work / Refurbishment (if any). NOTE : No Rig Months
under construction is acceptable
Estimated Time for Mobilization of Rig from its last location to Port Harcourt Months
(if Outside Nigeria)
Estimated Time to Rig Up (including standard acceptance tests) on first NAOC Location Weeks
DUE UPGRADING/REFURBISHMENT/MOBILISATION TIME: (Mandatory) May
2018
IDENTIFICATION CODE PAG3OF126
COMPANY MIN.
ITEM DESCRIPTION CONTRACTOR'S DATA
REQUIREMENTS
A. UNIT Specifications
A.1. Unit general data
Owner +
Rig Operation manager +
Owner Head Office address +
Management head office address +
Owner Head office telephone +
Management head office telephone +
Unit Name +
Unit Type SWAMP BARGE DRILLING UNIT
Registered Number +
Unit Classification As per IMO MODU code (Where
App.)
Rated drilling depth 30.000 ft with 5" DP
Year of construction Not before 1995
Construction yard +
Actual status +
Actual location (December 2007) +
Availability
No. of Engines 6
Engines power 1500 HP
Average fuel consumption in normal drilling +
operation (Bbl’s)
A.1.1 Main dimension of Hull
Light Ship Weight [MT]
COMPANY MIN.
ITEM DESCRIPTION CONTRACTOR'S DATA
REQUIREMENTS
B.4 Rotation System
B.4.1 Rotary Table
Make/Type +
Maximum opening 37” ½
Rated static capacity [MT] 900
Rated rotation capacity (@100 RPM) [MT] +
Driven by an independent electric motor. [Yes/No] +
- Type +
- Make +
- Output power [kW] +
Maximum continuous torque [ft.lbs] +
Two speed gearbox. [Yes/No] +
Emergency chain drive electric motor [Yes/No] +
Anti slipping pad [Yes/No] Required
Soft Torque Rotary System [Yes/No] +
B.4.2 Master Bushings
Make +
Type +
Full range of inserts blows to suit running all casing sizes 24” - 20 “- 18”⅝ - 16”
COMPANY MIN.
ITEM DESCRIPTION CONTRACTOR'S DATA
REQUIREMENTS
B.4.4 Top Drive
Make Varco or equivalent
Type +
Builder as per rules: API 8 C
Static rated load capacity [MT] 680
Working pressure [psi] 10.000
At related rotary speed [RPM] 150
Maximum rotary speed [RPM] 250
Driven by electric/hydraulic motor +
- Make +
- Type +
- Output power [HP] 1,200.
- Output torque [Lbs/ft] Range at …100 RPM 48,000
Electric motor cooling system (if applicable) +
Cooling system air intake (if applicable) +
System Certified by Required
Link Tilted System Required Hydraulic type
Two-speed gearbox [Yes/No] +
Specify lower connection size of main shaft [inch] +
B.4.4.1 Top Drive Inside BOP:
a. Hydraulic Remote operated Inside BOP make and type +
Hydraulic Remote operated [No.] 1 + 1 Spare
For DP sizes [Inch) 5” - 3”½
Inside diameter [Inch] 3” 1/16
Outside Diameter [Inch] +
IDENTIFICATION CODE PAG13OF126
COMPANY MIN.
ITEM DESCRIPTION CONTRACTOR'S DATA
REQUIREMENTS
Maximum working pressure [] 15,000
Builded as per rules: API 8C
b. Manual operated Inside BOP make and type +
Manual operated [No] 1 + 1 Spare
For DP sizes [Inch] 5” - 3”½
Inside diameter [Inch] 3” 1/16
Outside Diameter [Inch] +
Maximum working pressure [PSI] 15,000
Builded as per rules: API 8C
B.4.4.2 Top Drive Pipe Handler System
Unit fitted with pipe handler for make up and break out +
[Yes/No]
Make +
Type +
Maximum Break-Out Torque [ft.lbs] 85.000
NOTE: Copy of manufacturer drawings of line components and calculations on load capacity of shaft to be submitted.
B.4.4.3 Top Drive Saver sub
For Dp’s 5” and 5 ½’’
Quantity 4 NEW
Top connection type +
Bottom connection type NC 50
Builded as per rules: API 8 C
Top Drive Saver sub (continue )
For Dp’s 3” ½
Quantity 4 NEW
Top connection type +
Bottom connection type NC 38
Builded as per rules: API 8 C
B.4.4.4 Top Drive Wire Line accessories
Accessories Kit Required
Spare parts list for one year activity Required
B.4.4.5 Top Drive Link Elevators [refer to Item E.2.4]
IDENTIFICATION CODE PAG14OF126
COMPANY MIN.
ITEM DESCRIPTION CONTRACTOR'S DATA
REQUIREMENTS
B.4.4.6 Top Drive Video Camera
Video Camera installed at derrick-man platform, including pan and tilt unit complete with cable, hoist, sheaves, ecc.
two monitors, of which one at the driller's doghouse, and specific spare.
TV camera:
Quantity [No] Required
Make +
Type +
Quantity of TV monitors [No] 2
Monitors Make +
Monitors Type +
Located at +
Certified to be installed in hazardous area Requested
IDENTIFICATION CODE PAG15OF126
B.5.4.2. BOP Handling System inside The Substructure (See D.1.5 - K.1.4 )
CONTRACTOR'
COMPANY MIN.
ITEM DESCRIPTION UNIT S
REQUIREMENTS
DATA
E.1.10.5 DP’s Circulating Head a. b. a. b.
For DP outside diameter Inch 5 3 1/2
Quantity No. 1 + 1 Spare 1+ 1 Spare
Make + +
Type + +
Valve name Low - Torque Low - Torque
Valve type + +
Valve size Inch 2 2
Valve working pressure PSI 15.000 15.000
Bottom connection NC 50 NC 38
Top connection 2” Weco 1502 2” Weco 1502
IDENTIFICATION CODE PAG45OF126
Connection a. b. c. d. a. b. c. d.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
Connection + + + +
Connection e. f. g. h. e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
X-Over OD Inch + + + +
X-Over ID Inch + + + +
e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
X-Over OD Inch + + + +
X-Over ID Inch + + + +
e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
X-Over OD Inch + + + +
X-Over ID Inch + + + +
e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
X-Over OD Inch + + + +
X-Over ID Inch + + + +
e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
X-Over OD Inch + + + +
X-Over ID Inch + + + +
e. f. g. h.
X-Over OD Inch + + + +
X-Over ID Inch + + + +
Quantity No. + + + +
IDENTIFICATION CODE PAG52OF126
ITEM Connection + + +
Inch
E.4.2.1 Hydraulic Fishing Jar
Quantity No 1 1 2
Make Bowen Bowen Bowen
Model Z Z Z
OD body Inch 8” 6” 1/2 4” 3/4
Minimum ID Inch + + +
Connection NC 50 NC 50 NC 38
The Mud Tester shall, on behalf of the Company, be responsible for supervising the
performance monitoring, reporting and maintenance of the equipment specified herein
and the condition monitoring, reporting and maintenance of the mud properties.
The Mud Tester shall be responsible for the safe storage and handling of all
materials (bulk and palletized), chemicals and bulk liquid used in conjunction
with the above equipment specified herein.
IDENTIFICATION CODE PAG84OF126
1.6 INSTRUMENTATION.
ITEM DESCRIPTION UNIT COMPANY MIN. REQUIREMENTS CONTRACTOR'S DATA
G Instrumentation
G.1 Drilling Instrumentation
G.1.1 Instruments at Driller's Position REQUESTED
G.1.1.1 Weight Indicator (10 or 12 Lines Strung)
Make Martin-Decker
Type +
Sensor Range Tons +
G.1.1.2 Standpipe Pressure Gauges
Quantity No. 2
Make +
Type +
Pressure range psi a range of all gauges shall be adequate
G.1.1.3 Choke Manifold Pressure Gauge
Quantity No. 2
Make +
Type +
Pressure range psi a range of all gauges shall be adequate
G.1.1.4 Rotary Speed Tachometer Rotary Table Top Drive Rotary Table Top Drive
Make 1 1
Type + +
Capacity range RPM + +
G.1.1.5 Rotary Torque Indicator Rotary Table Top Drive Rotary Table Top Drive
Make 1 1
Type + +
Torque Range + +
G.1.1.6 Pump Stroke indicator and Stroke counter
Consisting of stroke indicator and cumulative pump stroke counter of each one pump.
Make
Type +
Indicator sensor Analog or Digital Yes/No Requested
G.1.1.7 Tong Torque Indicator
Make 2 +1 Backup
Type +
Capacity range lb*ft +
G.1.1.8 Pit Volume Totaliser
Complete with floats in active mud tanks and on reserve tank complete with loss gain indicator and alarm (audio and visual)
Tanks were installed +
Make +
Model +
Pit Volume Gain/Loss Alarm Yes/No Requested
G.1.1.9 Mud Flow Indicator
Make +
Model +
High/low alarm (audio/visual) Yes/No Requested
G.1.1.10 Trip Tank mechanical Indicator and pneumatic/electronic indicator
Make +
IDENTIFICATION CODE PAG85OF126
1.8 ACCOMMODATION.
ITEM DESCRIPTION UNIT COMPANY MIN. REQUIREMENTS CONTRACTOR'S DATA
I Accommodation: With full climate control for Nigeria weather conditions
I.1 Offices
I.1.1. Company drilling Supervisor's and Operations engineer's office.
Requested complete with desk, filing cabinets, No 2 personal computer with Windows and Microsoft Office installed, Laser Jet or
color printer, photocopier, and all necessary furniture.( See K.10 )
Unrestricted View to Drill Floor Requested
Quantity No. 1
Size +
Telephone facility Yes Requested
Living room Yes/No. Requested
Toilet and shower Yes/No. +
I.1.2. Company Geologist and Directional drilling engineer’ office
Requested complete with desk, filing cabinets, No 1 personal computer with Windows and Microsoft Office installed, Desk-Jet or
color printer, photocopier, and all necessary furniture.
Unrestricted View to Drill Floor Requested
Quantity No. 1
Size +
Telephone facility Yes Requested
Living room Yes/No. Requested
Toilet and shower Yes/No. +
I.1.3 Contractor Toolpusher office
Requested complete with desk, filing cabinets and all necessary furniture.
Unrestricted View to Drill Floor Requested
Quantity No. 1
Size +
Telephone facility Yes +
Living room Yes/No. +
Toilet and shower Yes/No. +
I.1.4 Dressing Room for Contractor and Company use
Requested complete with all necessary furniture.
Quantity No. 1
Size +
Toilet and shower Yes +
I.1.5 Office Room for contractor Company’s use
Requested complete with all necessary furniture, telephone power connection one computer with internet connection, spare
internet line.
Quantity No. +
Size +
Toilet and shower Yes +
IDENTIFICATION CODE PAG94OF126
I. 2.2 Electric Semisubmersible Pump to supply potable water from the water wells ( Ref K.8. 4.)
Quantity No 3
Make +
Type +
Power kw 3
Frequency Hz +
Electric Board Yes +
Flow rate m3/hr +
PVC hose to connect pump to the rig Ft As it is requested
Electrical cable and switch to power the pumps Ft As it is requested
I.3 House –Boat Accommodation Required
House Boat with full climate control for Nigeria weather conditions Yes/No Required
House Boat comply with International Safety Rules Yes/No Required
(IMO MODU CODE)
Living Quarters are Positive pressurized Yes/No Required
Total accommodation for Personnel No. Minimum 100
(Company Pers. Min. 50)
I.3.1 Accommodation
Separate accommodation for Company staff No. 10 single bed
Complete with own shower/bathroom, TV & Satellite Yes
Accommodation for Company's Other staff No. 40 Double beds
Complete with own shower/bathroom Yes
Accommodation for Company's Other Contractor personnel (Army) No. 15 Four beds
Yes
Galley local + Galley continental No. 1 +1
Local staff mess room for No of peoples No. 50
Local contractor mess room for No of peoples No. 20
Continental mess room for No of peoples No. 10
Senior Recreation room complete with ( TV & DVD Player & Satellite ): No. Requested
Junior Recreation room for No of peoples( TV & DVD Player & Satellite ): No. Requested
Contractor Company’s Recreation room for No of peoples( TV & DVD No. Requested
Player & Satellite ):
Water Distillation Unit and Water filter Unit with Sterilizer system No. Requested
Laundry room complete with: No 3 washing machine, No 2 drier No. Requested
Dry food store No. Requested
Mineral & water store No. Requested
Refrigerator vegetable store No. Requested
Refrigerator meat room No. Requested
Refrigerator fish room No. Requested
Accommodation for Catering & cleaning Contractor’s personnel No. 10
Accommodation for house boat Contractor’s personnel No. 10
Water Boiler for shower and kitchen No. 2
IDENTIFICATION CODE PAG98OF126
COMPANY MIN.
ITEM DESCRIPTION UNIT CONTRACTOR'S DATA
REQUIREMENTS
J.2 Gas Detection
Responsible person(s) for repairing/testing/maintaining gas detection equipment:
Responsible Person Qualifications YES
J.2.1 H2S Monitoring System REQUESTED
Make +
Type +
Calibration Kit No. 3
H2S Monitoring Main Panel Location Radio room
H2S Monitoring Repeat Panel Location Rig Floor
H2S Sensor Installed No. 15
Sampling points at:
Bell nipple Yes Requested
moon Pool Area Yes Requested
Drill floor Yes Requested
shale shaker Yes Requested
Mud tanks room Yes Requested
Mud pump room Yes Requested
engine room Yes Requested
All suction point air conditions for area Yes Requested
living quarter and for all the pressurized
unit.
machinery deck air intake Yes Requested
Others Yes +
C/w general alarm Yes Requested
Alarm points (A = Audible; L = Light):
Driller's console A+L
Engine room A+L
Active mud tanks room A+L
Shale shaker room A+L
Others: main deck, contractors cabin A+L
control room, mechanic & electrical
work shop, moon pool & pump area.
H2S signs Requested
Windsocks Requested
Training video Requested
J.2.2 Combustible Gas Monitoring System REQUESTED
Make +
Type +
Calibration Kit No. Requested
Gas Monitoring Main Panel Location Radio room
Gas Monitoring Repeat Panel Location Rig Floor
Gas Sensor Installed No. +
Sampling points at:
bell nipple Yes/No Requested
IDENTIFICATION CODE PAG101OF126
COMPANY MIN.
ITEM DESCRIPTION UNIT CONTRACTOR'S DATA
REQUIREMENTS
moon Pool Area Yes/No Requested
drill floor Yes/No Requested
shale shaker Yes/No Requested
mud tanks room Yes/No Requested
mud pump room Yes/No Requested
engine room Yes/No Requested
All suction point air conditions for area Yes/No Requested
living quarter and for all the pressurized
unit.
machinery deck air intake Yes/No Requested
Others: main deck, contractors cabin Yes/No +
control room, mechanic & electrical
work shop, moon pool & pump area,
C/w general alarm Yes/No Requested
Alarm points (A = Audible; L = Light):
Driller's console A+L
Engine room A+L
Active mud tanks room A+L
Shale shaker room A+L
Others: main deck, contractors cabin A+L
control room, mechanic & electrical
work shop, moon pool & pump area.
IDENTIFICATION CODE PAG102OF126
COMPANY MIN.
ITEM DESCRIPTION UNIT CONTRACTOR'S DATA
REQUIREMENTS
J.2.3 Portable H2S Detector
Quantity ( Minimum) No. 3
Make +
Type +
Phials for H2S measuring range
from 1 to 20 ppm No. 50
from 20 to 100 ppm No. 50
from 100 to 600 ppm Yes/No 30
J.2.3.1 Electronic portable H2S detectors YES
Quantity ( Minimum) No. 4
J.2.4 Portable CO2 Detector
Quantity (Minimum) No. 2
Make +
Type +
Store sites +
Phials for CO2 measuring range
from 1 to 20 ppm No. 30
from 100 to 600 ppm No. 15
Zone 1 Classification Yes/No Requested
J.2.5 Gas Detector
Quantity No. 4
Make/Type +
Store sites +
J.2.6 Personal Electronic H2S Detectors
Quantity ( Minimum) No. 4
Make +
Type +
IDENTIFICATION CODE PAG103OF126