You are on page 1of 6

products

> NBC Air Filtration Unit

OUTSIDE 35 C
HUMIDITY 90%

22º C Inside
PROVIDED BY
HEINEN & HOPMAN

Heating Ventilation Air Conditioning Refrigeration


INTRODUCTION

Naval vessels have to operate now a day more and more overpressure controllers, a safe operating
under the threat of an attack by TIC’s and TIM’s. To be environment (citadel) is created, ensuring
able to operate under these circumstances without the optimal performance of the crew and
being contaminated, reliable NBC filter systems are of electronic equipment. Our NBC filter units
the essence. With our NBC filter units, provided with are available in a capacity range of 900 up to
STANAG4447 filter elements, in combination with our 1800m3/h.

APPLICATION

Our nuclear, biological and chemical (NBC) filtration system provides clean filtered fresh air, free from
NBC contaminates in an over pressure citadel. Three levels of filtration (coalescer, dust, and composite
filtration) is applied to incoming air before being supplied to the citadel. The over pressure citadel
removes the need for occupants to wear gas masks and protective clothing during NBC attacks. Two
modes of operation allows clean fresh air to be supplied during peace time, or conventional combat times,
and filtered fresh air during NBC warfare.
The control system constantly compares inside and outside pressures, and should the citadel
pressurization fail, provide a visual and/or audible warning.
The NBC filter unit is designed for external installation to citadels with a supply duct to the citadel interior.
The NBC control unit is designed to be installed internally within the citadel covering the air duct to diffuse
air entering the citadel. When the NBC filter unit is operational the unit is designed as a fail-safe system,
i.e. should the unit sustain damage or an air seal leak, then clean air will leak out of the unit rather than
contaminated air being drawn in.

KEY FEATURES

• Unique innovative design;


• Smart and powerful NBC / TIM Filter clamping system;
• Easy service and maintenance access;
• Compact and lightweight;
• Completely closed system;
• Doors equipped with end switches
• Analyzed for gas tightness, shock, vibration and EMC;
• High shock resistance. Up to 60g vertical
• Design according NATO standard;
• Design according STANAG 4447;
• NBC Filter capacity 900, 1200 and 1800m³/h.
FUNCTIONING
AFU 1800 & AFU 1200

Technical Data AFU-1800 50Hz / 60Hz

Air quantity 1.800m3/h

Pst 1.000Pa

Execution SS316L

Filters 6pcs

Power supply fan 3x380V-50Hz / 3x440V-60Hz

Rated power 4.0kW / 4.8kW

Power supply heater 3x380V-50Hz / 3x440V-60HZ

Capacity 10kW

Power supply valves 1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters) 1.350kg

Weight (excl. NBC filters) 1.170kg

Control panel (separate delivery) 760x760x300mm

Technical Data AFU-1200 50Hz / 60Hz

Air quantity 1.200m3/h

Pst 1.000Pa

Execution SS316L

Filters 4pcs

Power supply fan 3x380V-50Hz / 3x440V-60Hz

Rated power 4.0kW / 4.8kW

Power supply heater 3x380V-50Hz / 3x440V-60HZ

Capacity 10.5kW

Power supply valves 1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters) 1.350kg

Weight (excl. NBC filters) 1.170kg

Control panel (separate delivery) 760x760x300mm


AFU 900

Technical Data AFU-900 50Hz / 60Hz

Air quantity 900m3/h

Pst 1.000Pa

Execution SS316L

Filters 3pcs

Power supply fan 3x380V-50Hz / 3x440V-60Hz

Rated power 2.6kW / 3.12kW

Power supply heater 3x380V-50Hz / 3x440V-60HZ

Capacity 10.5kW

Power supply valves 1x230V-50Hz / 1x230V-60Hz

Weight (incl. NBC filters) 900kg

Weight (excl. NBC filters) 810kg

Control panel (separate delivery) 760x760x300mm

Alternatives available on request.


Owing to continued product development Heinen Hopman reserves the right to introduce alternations without prior notice.
Brazil India Norway Romania Spain UAE (Dubai)
T: +5521 3587 4241/4244 T: +9133 6499 1293 T: +47 6919 0900 T: +402 3644 8222 T: +349 3225 9668 T: +971 4263 5453
E: info@br.heinenhopman.com E: info@heinenhopmanindia.com E: admin@teknotherm.no E: office@ro.heinenhopman.com E: info@es.heinenhopman.com E: info@caspuae.com
France - La Ciotat Italy Peoples Republic of China Russia Sweden USA - Fort Lauderdale, Florida
T: +334 4204 8685 T: +3901 8745 7970 T: +8621 3253 2896 T: +7 (4012) 308 801 T: +46 3121 7500 T: +195 4463 0110
E: info@heinenhopmanfrance.com E: info@it.heinenhopman.com E: info@cn.heinenhopman.com E: info@heinenhopman.ru E: mats.uden@teknotherm.no E: info@arwmaritime.com
France - Grasse The Netherlands (HQ) Peoples Republic of China Singapore Turkey USA - Houma, Louisiana
T: +336 3090 7786 T: +313 3299 2500 T: +86 510 8528 1763 T: +65 6897 7879 T: +9021 6493 8118 T: +198 5876 7989
E: info@heinenhopmanfrance.com E: info@heinenhopman.com E: ivo.klaric@teknotherm.no E: info@sg.heinenhopman.com E: info@tr.heinenhopman.com E: leblanc@leblancandassociates.com
Germany The Netherlands (Rotterdam) Poland South Korea UAE (Abu Dhabi)
T:+49 4073 1680 T: +317 8890 8050 T: +489 1433 1800 T: +8270 4901 0000 T:+971 2550 4147
E: info@drewsmarine.com E: binnenvaart@heinenhopman.nl E: tmh@teknotherm.no E: info@kr.heinenhopman.com E: info@caspuae.com

Heinen & Hopman


encourages a more
sustainable world. By
providing eco-friendly
solutions and services
we offer our clients
the option of reducing
energy consumption
and thus CO2
emissions. Visit
greenmanifest.info for
more information.

www.heinenhopman.com

You might also like