i. Beam Depth of Beam, Dbeam = 1/10th to 1/15th of span For Long Span = 1/10th to 1/15th X 5420mm = 360-542mm For Short Span = 1/10th to 1/15th X 4580mm = 305-458mm
Adopting Depth of Beam as 400mm and 450mm
Width of Beam, bbeam = 1/3rd to 2/3rd of depth = 135-270mm
ii. Slab Thickness of Slab, D = 1/28th to 1/32nd of span = 1/28th to 1/32nd X 3.82m = 120-135mm
Hence, adopt slab thickness as 130mm
iii. Loads on Slabs and Beams
a. Self-Wt. of Beam = 25x.405x.23 = 2.33 kN/m
b. Slab Self-Wt. = 25x.125 = 3.125 kN/m2 Finishing = .025x22 = 0.55 kN/m2 Screed = 0.02x20.4 =0.41 kN/m2 Plaster = 0.01x20 = 0.2 kN/m2 Light Partition = 1 kN/m2 Live Load = 4 kN/m2 c. Self-wt. of other component Main Wall = 0.23x20x(3.3-0.405) = 13.32 kN/m = 11kN/m (assuming 20% opening) Partition Wall = 0.115x20x(3.3-0.405) = 6.66 kN/m = 5.5 kN/m (assuming 20% opening) Parapet = 0.23 x 20 x 1 = 4.6 kN/m
iv. Determination of Column Size:
Tributary Area = 4.3 x 4.9m Slab Wt. = 3.125 x 4.3 x 4.9 = 65.84 kN FF Load = 1.5 x 4.3 x 4.9 = 31.6 kN Live Load = 4 x 4.3 x 4.9 = 84.28 kN Beam = 25 x 0.23 x 0.405 x 4.3 + 25 x 0.3 x 0.405 x 4.9 = 24.9 kN Wall = 5.5 x 9.2 = 50.6 kN Total Load = 7 x 257.22 = 1800.54 kN Factored Load = 2700.81 kN
Taking % of steel as 2% and fy = 500 N/mm2, fck = 20 N/mm2
According to IS 456:2002 Cl 39.3 for axially loaded column
P = 0.4 x fck x Ac + 0.67 x fy x Ast
2700.81x103 = 0.4 x 20 x Ac + 0.67 x 500 x 0.02 Ac Ac = 183728 mm2 Size = 430 x 430 mm Adopted Size = 450 x 450 mm Ac = 202500 mm2 v. Size of Structural Members: Structural Member Size Columns: Main Columns 450mm X 450mm 2 Columns in Lift 400mm X 150mm Beams: Longer Span 300mm X 450mm Shorter Span 230mm X 400mm Floor Slab 130mm Staircase Slab 130mm Shear Wall 150mm Retaining Wall 200mm