Professional Documents
Culture Documents
1
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Office Division
ACTIVITY/FUNCTIONS: Managerial and clerical works, Customer service for present and prospective tenants in the
Business Level
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Client, Manager,
5 5 m2 25 m2 ● ●
Clerk
2
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Internal Auditing Office
ACTIVITY/FUNCTIONS: Management of business structure, employee behavior and information systems, Verification of
financial reports
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Office Head, Clerk 5 5 m2 25 m2 ● ●
3
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Conference Room
ACTIVITY/FUNCTIONS: Assembly and meeting of administrative officers
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Corporate officers 10 2m 2 20 m 2
● ●
4
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Public Relations Office
ACTIVITY/FUNCTIONS: Management of the company’s communications, publicity and promotions
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Office Head, Clerk,
5 5 m2 25 m2 ● ●
Client
5
PUBLIC AND COMMERCIAL SERVICES
6
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Atrium with Fountain
ACTIVITY/FUNCTIONS: Sitting and leisure area, Light and ventilation shaft
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Client 1000 1.5 m 2 1500 m 2
● ●
7
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: ATM Center
ACTIVITY/FUNCTIONS: Basic cash transactions, Electronic banking outlet
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Client 10 1.5 m 2 15 m 2
● ●
8
BUSINESS AND OFFICE SERVICES
9
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Meeting Area
ACTIVITY/FUNCTIONS: Assembly area, Lecture room
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Office tenants, Staff 100 2m 2 200 m2
● ●
10
RESIDENTIAL (CONDOMINIUM, HOTEL, AND PENTHOUSE) SERVICES
11
BACK OF THE HOUSE
12
NO. OF TOTAL
AREA/PERSON Pu SP P N A C
USERS AREA/USER
Staff 2 3 m2 6 m2 ● ●
13
ACTIVITY/FUNCTIONS: Private passageway for building employees
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Staff 50 1.5 m2 12 m2 ● ●
14
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Pump House
ACTIVITY/FUNCTIONS: Plumbing control room for water supply and sewage system
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Staff 3 3m 2 9m 2
● ●
15
NO. OF TOTAL
AREA/PERSON Pu SP P N A C
USERS AREA/USER
Office Head,
Security Personnel, 4 1.5 m2 12 m2 ● ●
Staff
16
SALON
17
BUILDING: A Proposed Mixed-Use Building Project with Basement Component
SPACE/AREA: Shampoo Area
ACTIVITY/FUNCTIONS: Hair washing and shampoo area
SPACE REQUIRED PRIVACY LIGHTING
TOTAL
USERS NO. OF
AREA/PERSON AREA/USER Pu SP P N A C
USERS
Staff, Client 10 1.5 m 2 15 m 2
● ●
18
SPA
19
HOTEL
20
CONDOMINIUM
21