The 3-dB coupler has four ports, two of Diagram I
earth screw M6
which are decoupled from each other. Typical attenuation between ports
Attenuation 1 ↔ 3 / dB
Attenuation 1 ↔ 2 / dB
1 ↔ 2 resp. 1 ↔ 3 vs. frequency
For example effective power entering
into port 1 is distributed into the ports 2 1↔ 2
and 3. Port 4 is decoupled and without 2.0
power if ports 2 and 3 are ideally
3.0
matched. In practice an absorber of
suitable power at port 4 is to be 4.0
coupler 7-16 1↔ 3
planned for according to the mismatch
of ports 2 and 3. 800 2200
Decoupled combining can be achived
via the diagonally opposite ports 2 and
1 3
3 respectively 1 and 4.
2 4
Technical Data
Diagram II
Type No. 793 554
Typical attenuation 2 ↔ 3 vs. VSWR at port 1
Frequency range 800 – 2200 MHz
Attenuation 1 ↔ 2 / 1 ↔ 3 3 ±1.2 dB (see diagram I)
Attenuation 2 ↔ 3 See diagram II
Directivity > 20 dB