You are on page 1of 11

GeN2 Regen

Duty Table
Rated Speed Load (Kg)
(m/s) 630 680 800 1000 1150 1275 1350 1600 1800 2000

1.00 50m/16F
1.50/1.60 75m/24F
1.75 75m/24F
1/66
Max. group control: G8C
GeN2 Regen
Space saving, energy saving, environmental friendly and excellent ride quality

Gen2 Machine Shenling Governor


(MOR)

CSB

NGSOK

Regen Drive
Controller
2/66
AES/AMS
GeN2 Regen

OTIS unique technology- Coated Steel Belt (CSB)

 20% less in weight while 2-3 times life time


 Lubrication free

×
 Size: 30 3 & 60x3
 Steel cords: 12 & 24
3/66
 Cord diameter 1.67mm
Technology from helicopter (Sikorsky)  Breaking load: 32KN & 64KN
GeN2 Regen

CSB makes GeN2 Regen machine much smaller

Roped Machine
Gen2 Machine

Diameter of sheave:100mm Diameter of sheave:115mm


Groove:3/5 Groove:5
Brake voltage:24V Brake voltage:24V
Insulation class: F Insulation class: F

4/66
GeN2 Regen
CSB Monitor
CSB monitor (RBI)
– Resistance Based Inspection (RBI) for CSB
– Dynamic inspection of CSB status
– LED indication
– Elevator level at nearest floor when failure inspected
– REM interface
– A component, not a tool

5/66
GeN2 Regen OTIS GECB Controller board

 Motorola 32 bit CPU with 1M Flash memory.


 Rear time failure clinic automatically
 CAN BUS 2.0 communication
 CE Comply
 ESD to avoid jobsite damage
 Up to100 floors and 4m/s

ESD: Electro-Static discharge

6/66
GeN2 Regen ACD2 MRL Controller and Drive

 OTIS energy regenerative drive


 CAN-bus communication
 Mini E&I Panel

Drive E&I Panel Controller


210W x 540H x 90D 7/66 320W x1300H x 160D
GeN2 Regen

Regen
Principle
Regenerative
system

+ Energy saving
Up to

OTIS Regenerative Drive OTIS Gen2 Machine

8/66
GeN2 Regen NGSOK Door operator

Key parameters:

Center Opening 700 800 900 1000 1100 1200

Open Time(s) 2.2 2.3 2.5 2.9 3.3 3.7

Close Time(s) 2.4 2.5 2.7 3.1 3.5 3.9


• PM motor, energy saving Re-open Distance(mm) 100

• VVVF controller Open/Close noise(dBA) 52 (Peak)

• Motor drive directly, no gearbox Re-open noise(dBA) 55 (Peak)

• Disc motor, space saving


– Side opening is availble OP=900~1300
• Easier for installation
– Standard opening height:2100/2000
• Max. moving mass: 200kg
• Motor IP: 44
9/66
For Gen2 Regen and also for all other passenger elevators
GeN2 Regen Safety Components
E3 Qualified

– Otis US design qualification


– Otis US MFG process control
– Otis US change control
– Reliable
– Durable
– Traceability
Safety Gear Speed governor Oil buffer

Comparison

Component OTIS E3 Requirements EN81-1 Requirements


Safety Gear 25 freefall and runaway test 4 freefall test
Speed Governor 25 Continuous tripping 20 Continuous tripping
10/66
Buffer 100 strike test 6 strike test
GeN2 Regen
Excellent Performance Data

System performance Gen2 Regen Traditional lift


(Belted, gearless) (Roped geared)

X- Vibration A95 (mg) ≤9 ≤ 11

Y- Vibration A95 (mg) ≤9 ≤ 11

Z- Vibration A95 (mg) ≤ 11 ≤ 14

Speed Tolerance (%)


+3 +5
(@+10%VRate, +1%fRate, Tmax 40℃)

Maximum Acceleration( m/s2)


1.2 1.2
(@ start and stop)

Maximum Jerk ( m/s3)


1.0 1.0
(@ running)

Noise (dB)
≤ 72 ≤ 75
(@ Machine room)

Noise (dB)
≤ 53 ≤ 53
(@ In car, w/o fan, running )

Level accuracy (mm) Typical: ±3


±5
(@+7%VRate, +1%fRate, Tmax 40℃) Max. : ±5

11/66