You are on page 1of 4

Field Service Ver. 4.0 Jun. 2008 3.

Periodical check

bizhub C353/C253/C203
3.4.13 Replacing the imaging unit
A. Periodically replacing parts/cycle
• Imaging unit Y,M,C : Every 90,000 prints (bizhub C353)
: Every 75,000 prints (bizhub C253)
: Every 55,000 prints (bizhub C203)
• Imaging unit K : Every 120,000 prints (bizhub C353)
: Every 100,000 prints (bizhub C253)
: Every 70,000 prints (bizhub C203)

NOTE
• Although the procedure shown below is for the replacement of the imaging unit K,
use the same procedure to replace other imaging units Y,M,C.

B. Removal procedure
1. Open the front door.
2. Press down to release the unlock
lever [1] of the imaging unit to be
replaced.

Maintenance
K
[1]
K

A02EF2C504DA

3. Remove the imaging unit [1].

[1]

A02EF2C507DA

35
3. Periodical check Field Service Ver. 4.0 Jun. 2008
bizhub C353/C253/C203

C. Reinstall procedure
1. Remove the imaging unit [1] from its
[1]
packaging.

A02EF2C508DA

2. Peel off the tapes, and then remove


[1] the packing materials [1].

[1]
Maintenance

A02EF2C509DA

3. Remove the imaging unit [2] from the


[1] black protective bag [1].

[2]

A02EF2C510DA

36
Field Service Ver. 4.0 Jun. 2008 3. Periodical check

bizhub C353/C253/C203
4. Tilt the imaging unit [1] to the left and
shake it a little left to right twice.
[1] Then, tilt the imaging unit to the right
and shake it a little right to left twice.

A02EF2C511DA

5. Peel off the tapes [1].

[1]

Maintenance
A02EF2C512DA

6. Remove the packing material and


[1] securing material [1].

[1]

A02EF2C513DA

37
3. Periodical check Field Service Ver. 4.0 Jun. 2008
bizhub C353/C253/C203

7. Align the ▲ mark on the imaging unit


with the ▼ mark on the main body.
Install the imaging unit [1] into the
main body.

[1]
A02EF2C514DA

8. To remove the protective sheet [1]


[1]
which guards against PC drum dam-
age, slowly pull its tab.
Maintenance

A02EF2C515DA

9. Insert the imaging unit [1] completely


and close the front door.

[1]

A02EF2C516DA

38