Fläkt Woods experience – at your service Total air movement solutions – precisely

Our knowledge and reputation has been The perfect solution


Fläkt Woods is a global built up through a century of engineering Air movement in occupied Contents
The ideal air movement equipment
leader in air management. innovation and development. This reflects buildings has many roles will satisfy the correct combination General ventilation
an impressive track record that equips all
We specialise in the design our customers with a special confidence.
to play. Not just to bring of several factors, insofar as each
applies to a specific project: The perfect fit – reliability in action  4
and manufacture of An assurance that, whatever the need the ventilation and comfort
Function Hazardous areas
precision technology to or application, Fläkt Woods can deliver that are vital to human
the product, the performance and the Including air supply or extraction;
ATEX-compliant range  5
deliver complete, integrated service that is required. Precisely.
existence. It also has the heat transfer and recovery; drying;
solutions. In everything we potential to protect. blowing; particle transportation and
Our expertise is not confined to original Fire safety
filtering; and, in the event of fire,
do, energy efficiency and manufacture and supply. It is available Fans for Life Safety systems  6
emergency management of smoke
environmental responsibility to you from the selection process In an ideal world, this would all be
and toxic fumes When the heat is on 7
onwards, and continues well beyond achievable via natural, non-mechanical
are always our major processes. But reality is different. Flow Complete smoke extraction systems  8
installation, throughout each system’s
priorities. And our collective operating life. In most cases, and to varying extents, Required air volume capacity Protective ventilation for car parks  9
powered air movement is essential. and speed
experience is unrivalled. When you first select and install one or
more of our systems, our partnership with From functional operational routines, Energy efficiency
Legislation
you is only just beginning. Because you’ll to one-off emergency situations, fans Less energy consumed to achieve
always be able to call on Fläkt Woods have a front-line role to play in many the desired result ErP Overview  10-11
ENERGY experience. We’re at your service. built environments. And, whatever each Controllability
EXPERTISE precise need, Fläkt Woods certainly has Allowing performance to match Energy efficiency
ENVIRONMENT
the right solution. demand – no more, no less More function – less consumption  12-13
Sound Intelligent control – matching need  14-15
Quiet operation to avoid noise
distraction Range key details
Space availability Axial fans 16-17
Fitting the space or location available Box fans  18
Inline Fans, Box fans & Roof Units  19
At Fläkt Woods, we have the Centrifugal fans 20
technology and experience to give
you that combination.

From one expert source


Fläkt Woods has the widest range of
fans available in today’s market: from
the largest infrastructure fan; through to
compact, lightweight models designed
for small premises or domestic situations.
Fläkt Woods Systems to create integrated Fans
air quality solutions include That means we can deliver all the air
systems summary The widest selection for all sizes and
Axial and Centrifugal Fans types of application. These range from movement functions, capacity and
The comprehensive large supply and extraction fans for performance that a building or structure
Box Fans requires – whatever its size and
Fläkt Woods range service in industry or infrastructure,
Inline Fans through to compact and small units purpose.
serves a very wide for domestic ventilation – or as
Roof Units In short, our expertise has precisely the
spectrum of applications: components for air management answer you need.
Other Air Terminal
across Commercial, equipment. We also have specialist
Devices and Ducts
options and ranges to help deliver fire
Industrial, Public Integrated controls safety and extra energy efficiency.
and sectors.

2 3
General ventilation Hazardous areas

The perfect fit – reliability in action ATEX-compliant range

Whatever its function, it


must do it well. That is the
constant theme of all Fläkt
Woods product designs,
and is reflected in each
product’s performance
across our entire system
portfolio. Our fans are
widely recognised as today’s
premier range, and trusted
For introductory key details of
to go on doing the job – Fläkt Woods fan ranges, including
day in, day out. standard features and options,
see pages 16-21.
For assistance with identifying
precisely the right fan solution
for your specific projects, visit
www.flaktwoods.com/atex

The application context may vary, but Fan options for Compliance became a legal requirement We also have systems in place to
the fundamental requirements are the general ventilation Mechanical ventilation and in 2003. The Directive applies to a ensure continuous ATEX compliance
same: supply and extraction. System extraction can be required wide variety of equipment intended for during our normal production.
Units and ranges designed to provide
requirements will be dictated by building use in hazardous areas, such as petro-
size and function, and by numerous
routine ventilation and general air in environments which have chemical plants, pharmaceutical and Fan options for
movement functions for a variety of
other operational parameters, which the potentially explosive chemical manufacturing, battery rooms, ATEX environments
applications and environments include:
installed ventilation must satisfy. atmospheres – whether flourmills and grain silos. Fläkt Woods offers fully ATEX-compliant
Axial Fans
With Fläkt Woods, you have a genuinely from chemical vapours, Fläkt Woods has invested heavily in CE-marked fans in the following ranges:
comprehensive choice. We can be Bifurcated Fans fan engineering design modifications to
volatile gases or hazardous JM Aerofoil
relied on to have exactly the fan type, Box Fans achieve and satisfy the necessary high Axial fans range
model, performance, and capacity each dust. For these situations, specifications. For fans, these safety
Plate Fans Centripal EU
situation needs. You can also completely we have the widest range modifications include:
Centrifugal fans range
depend on the quality and reliability Tube Fans
of fans that comply fully with Features to avoid
of its engineering. Roof Units or minimise sparks
For introductory key details of the ATEX 100a Directive.
Centrifugal Fans Changes to the motors
Fläkt Woods fan ranges, including
Fläkt Woods also offers a and material thickness
standard features and options,
see pages 16-21. comprehensive choice of units for Impeller locking systems
whole house/domestic ventilation, as
For assistance with identifying Adjustments to impeller
well as mini air handling units for small
precisely the right fan solution tip clearances
commercial and industrial premises.
for your specific projects, visit
http://fanselector.flaktwoods.com

6 7
Fire safety

Fans for Life Safety systems When the heat is on

Fan options for


Within any building’s total Life Safety systems That’s when you need
functionality, one element Fläkt Woods units designed for total reliability, without
is paramount: its ability to emergency ventilation and smoke compromise. The capacity
extraction at high temperatures include:
ensure a safe environment to function even in extreme,
JM Aerofoil
in the event of emergency emergency circumstances.
JM High Temperature Aerofoil
conditions. If and when Efficiently controlling and
such a situation occurs, JM Bifurcated Aerofoil extracting smoke, fumes
Life Safety for the occupants JM Multi-stage Aerofoil and hot air – on demand.
and for emergency services, Centrifugal Single Inlet

and damage limitation for the UDA & DVA High Temperature Fläkt Woods’ axial and centrifugal ranges
Roof Units General specifications are designed to give you precisely that
building fabric, immediately assurance. They offer high temperature
All these fan types are suitable for Fläkt Woods fans for smoke control
becomes the priority for the both normal and emergency smoke and fire safety are supplied with the performance that is ready to respond if
ventilation system. ventilation conditions, and can be following general specifications: the situation arises, and safe operation
inverter speed-controlled. that deserves the confidence of
Installation
designers, installers and users.
Fläkt Woods has the necessary In normal mode, they have lower –S uitable for internal
experience, and product options Specific Fan Power (SFP) values and and external mounting Emergency temperature
available, to manage such important optimised running costs, because the –R un and standby operation, capabilities
risk factors. inverter controls average power in parallel or series
While our units for emergency situations
consumption and extract rate. Standards
100 years of air movement knowledge, are suitable for normal ventilation
combined with our in-house expertise –E  N 12101-3 compliant operation, they are specifically designed
Specific control functions
and contributions to the development –A  erodynamic tested to for one-off operation at the following
of industry standards, mean we are well Our fan technology plays several BS ISO 5801:2007 temperatures:
placed to respond to new challenges important roles in the event of an –A  coustic tested to
emergency condition. Each could BS 848-2.5:2003 200°C for 2 hours
and regulation changes.
be an important defence against – CE-marked 250°C for 2 hours
Through continuous Research,
life-threatening fumes and hot smoke:
Development and Innovation we have Motors 300°C for 2 hours
consistently advanced fan technology Control and removal of hot – IE2 motors where applicable
400°C for 2 hours
to deal with emergency fire protection. smoke/gases to give time for – IP55 rated motor protection
occupants to escape – even 100% X-rayed
Impeller
if the fan itself is subject to impeller components
–N
 on-stalling pitch blade angle
high temperatures
(available on certain fans) By the nature of the process, die casting
Extraction of ‘cool’ smoke while –X
 -ray examination of impeller of metals can conceal hidden porosity.
it remains unstable in the early castings This can structurally reduce core
stages of a fire strength, and increase the possibility
Pressurisation: supply of clean of fatigue or failure, especially at
air into escape routes to hold elevated emergency temperatures.
back smoke However, with Fläkt Woods’ axial fans,
Clearance: removal of residual you have the assurance that all cast
smoke after fire is contained impellers have been subjected to X-ray
and suppressed inspection to ensure test compliance
and product integrity.
Natural ventilation may be inadequate for
these needs, particularly where ‘cool’
smoke may be involved, and could be
compromised by prevailing winds.

8 9
Fire safety

Complete smoke extraction systems Protective ventilation for car parks

Fan options for car park ventilation


Fläkt Woods fan technologies designed for use
as part of these more complete, cost-effective
and tailored ventilation solutions for car parks
include:
• Jet Thrust Range:
Compact Profile
Slim-Line
Standard
Oval Profile
EV Range
In-line axial fans that are reversible, truly
symmetrical impellers to provide efficient flow
in both directions.

• Induction Thrust
Shallow-profile centrifugal fans, ideal for car
parks with significant height restrictions,
especially those requiring a unidirectional system
for clearance of air pollution and smoke.

Fläkt Woods has the experience Products for smoke Operating on demand Tailored solutions using CFD
In a fire emergency, smoke to provide complete and precisely extraction systems In enclosed or underground
Unlike these old-style systems, with Our car park solutions are individually
is a potential killer unless tailored solutions for almost any car parks, a fire emergency
Fläkt Woods can design, supply and Fläkt Woods solutions there is no modelled to suit each building’s layout.
industrial, commercial or residential
it is quickly controlled. applications including:
install complete systems for smoke requires fast, intelligent requirement for the ventilation system to Computational Fluid Dynamics (CFD)
extraction to suit the specific needs of run continuously. Our systems operate software, combined with Fläkt Woods
It can also hamper the action to contain and control
Warehousing each individual building. Each system only when required, using a series of in-house expertise and own
work of emergency services. may comprise the appropriate the problem. Fläkt Woods strategically placed, independently fully-researched input data, is used to
Multi-storey shopping malls
Whatever the type and combination of: technology, application controlled fans. plot the ideal number, type and location
Offices of fans required for each application.
function of a building, Design knowledge, expertise and Under normal operational conditions,
Multi-occupancy housing/ sensors detect pollution such as carbon A computerised 3D model evaluates
diligent planning for the apartment blocks Mechanical or natural state of the art software
monoxide (CO), Liquefied Petroleum airflow with only the main extract system
ventilation products
fast, effective removal and special-need environments such as: combine to provide a Gas (LPG) and Nitrogen Oxides (NOx). in use. This identifies main airflow
of smoke is an essential Control systems unique approach, with Selected fans automatically induce the routes and highlights any stagnant
Enclosed or underground
Sensors contaminated air and direct it to the or recirculatory areas. Our fans are then
provision to ensure car parks tailored solutions.
main extract point for discharge. superimposed upon this model and
personnel safety. In addition to powered extract fans, Electrical wiring
placed in optimum positions to achieve
Traditional car park ventilation techniques In the event of a fire emergency, Fläkt
we offer a comprehensive range Commissioning both normal extract and emergency fire/
are based on air change rates and duct Woods systems control the direction
of ventilation components to cover smoke extract.
runs with vertical droppers and high/low of smoke travel. Smoke sensors trigger
both daily requirements and
level grilles. This ducting typically uses up fans to run up to full design speed to Main extract fans in these installations
emergency situations.
valuable headroom and parking space, direct the smoke, via other fans as can be smaller because there is less
These products are tested to necessary, to the nearest extract point. ductwork resistance. Installation costs
and such systems are costly to install
BS EN 12101 specification standards Smoke, heat and toxic fumes are are lower and, because the system
and operate. Fläkt Woods can provide
for smoke and heat control systems. removed swiftly and safely from a fire operates only when required, running
a modern alternative solution providing
benefit to client and user alike, whilst by the shortest route. costs are also minimised.
complying fully with the latest technical
requirements and European standards.

10 11
Legislation Requirements Legislation Requirements

ErP Directive - Objectives ErP


FansDirective
summary - Targets

+
“ErP” stands for “Energy related Products”. The associated Table 1
Directive supports the aims of the EU Climate and Energy Package
by encouraging the use of environmentally friendly designs (“Eco 125 W - 500 kW Efficiency Grade N
design”), in order to reduce greenhouse gas emissions by 20%, Fan Type Test Category 2013 2015
whilst also increasing the use of renewable energy sources in the
EEA (up to 20%) by 2020. However, the main focus of the ErP
directive is to increase combined fan and motor energy efficiencies
B - OPEN INLET AND DUCTED OUTLET
by 20%. This ethos is also known as the
“20-20-20” target. Although the ErP Directive only applies within ErP Compliant Product Identification ErP ErP
the EEA, others often adopt European legislation as best practice, Products that do not meet their required FMEG rating will therefore Cased Axial
especially as the Directive is based upon the Kyoto Protocol. Axial 50 58
not be ErP compliant, which in turn means that a CE mark cannot Impeller
be affixed to them. The CE Mark is a legal requirement for products
For this reason, within the main ErP Directive 2009/125/EC, to be sold within the EEA.
applicable standards have been developed for each specific
product group for use within the EEA. For fans, the Commission’s
regulation (EU) 327/2011 (also known as lot 11), applies. electric
motors and their construction are also covered separately by
Regulation 640/2009. Forward D - DUCTED INLET AND DUCTED
OUTLET
ErP ErP
Curved
Impeller
42 49

Centrifugal
For products which comply, there is a legal requirement to affix
a label which shows 5 key pieces of ErP related information, the Backward ErP ErP
FMEG grade, the measurement category, the efficiency category Curved 61 64
and the overall efficiency of the product at its optimum energy Impeller
efficiency point and if applicable, confirmation that the calculation of
fan efficiency is based on the use of an Inverter (VSD).

Although products which are ErP compliant will of course display a


CE mark, Flakt Woods products will also display a distinctive “ErP 125 W - 500 kW Efficiency Grade N
Products Affected compliant” logo (see below) to help customers identify compliant Fan Type Test Category 2013 2015
products. This logo will also be used in all relevant marketing
There are some exceptions, but most energy using products will be
material, selection tools, and packaging to assist in positive
affected by this ErP Directive. Electric motors are of specific interest A - OPEN INLET AND OPEN OUTLET
identification of compliant products.
to fan manufacturers as these are core to almost all products.
Regulation No. 640/2009, which sets the minimum efficiency
Regulation Exemptions and Allowances
requirements for electric motors, came into effect on 16th June
2011 and relates to electric motors rated between 0.75kW and Short Cased
Some fans which are designed to be used in particularly hazardous and Plate ErP ErP
375kW. On 1st January 2015, this will be extended to include Axial
electric motors with a rated output of 7.5kW to 375kW.
conditions are not required to comply with this directive. ATEX mounted 36 40
fans, high temperature fans (operating continuously at temperatures Axial Impller
above 100°C) or Smoke Extract fans designed for single emergency
Regulation 327/2011 Requirements
use operation are the most common exemptions.
All fan products incorporating motors which have an electrical input
power of between 125W and 500kW are within the scope of this Dual use fans which are designed to provide normal ventilation and
regulation. short-term emergency Smoke Extraction, do need to comply, but
can have additional grade allowances applied to compensate for
Fans are rated taking into account the combined motor and impeller the increased running clearances required in such products. C - DUCTED INLET AND OPEN OUTLET
efficiency to give an FMEG rating (Fan Motor Efficiency Grade),
which is then checked against the minimum pass grades stated
Backward ErP ErP
within the 327/2011 regulation (see table 1) and used to determine
if the complete product meets the target efficiency to enable it to Centrifugal Curved 58 62
be sold and used within the EEA. On the 1st January 2013 the (Plug Type)
first efficiency tier requirements for fans will be enforced, with a
second higher tier of efficiency targets coming into effect on 1st
January 2015. Manufacturers are legally required to ensure that their
products comply with this legislation

10 11
Energy efficiency

More function – less consumption

Energy efficiency is a core principle of Principles of extra


As the world tries to our fan design. Environmental concerns operational efficiency
are not the only factor. The problem of General specifications
combat and halt global More efficient solutions can also
escalating energy costs is a significant Fläkt Woods fans to achieve maximum
warming, the focus on additional incentive.
be achieved by recognising – and
energy efficiency are supplied with the
avoiding – factors that contribute to
energy consumption and its following general specifications:
So our development focus is always higher motor power requirements.
‘carbon footprint’ increases. firmly on two principal goals:
For example, run and standby JM Aerofoil Product range
If we can use less, that Delivering the same (or better) applications in series are more
Installation
footprint will be smaller. functions, while reducing the power-hungry than fans placed in parallel.
– Suitable for internal and
amount of power a fan needs That’s because, with parallel placement,
At Fläkt Woods, we are external mounting
Enabling it to operate only damper loss is less than idling fan loss,
–R  un and standby operation,
constantly applying our making it the preferred installation to
when needed in parallel or series
technological skills and reduce system resistance.
Within our total range, we can now offer Fan options for extra efficiency Achieving lowest SFPs (watts/ Standards
experience to the continuing motor efficiencies up to 97% and motor litre/second)
We do recognise that parallel positioning
–A  erodynamic tested to
Units designed to run at maximum may not always be possible, and that
drive for greater efficiency power factors of 0.9 and above.
efficiency, or avoid wasted energy No fan can run at 100% total efficiency:
BS ISO 5801:2007
systems need to be tailored to fit the
and reduced energy waste These are all reasons why you can rely by reacting automatically to changes –A  coustic tested to
some power is needed to deliver its requirements of each installation.
on Fläkt Woods to help you comply with in demand, include: BS 848-2.5:2003
in order to minimise the function. However, the primary objective
new or updated legislation, or solve a Nevertheless, by drawing on Fläkt – CE-marked
iFan Single Box Fan is to minimise the ratio of power to
environmental impact. specific building requirement. With our volume flow rate – using less power to
Woods’ extensive experience, fan
Motors
Life Cycle Costing assessments, iFan Twin Box Fan selections can be optimised for any
deliver more volume flow rate. – IE2 where applicable
we can ensure that both energy situation – typically with smaller motors,
Inverters (E.C.A. approved products) – IP55 rated motor protection
Recent Building Regulation updates lower noise levels, reduced SFPs and
consumption and running costs are
JM Aerofoil (with IE2 motors) now include SFP values, and apply less power consumed.
reduced to a minimum.
JM High Temperature Aerofoil to both new and existing buildings.
(with IE2 motors) For new buildings, these regulations
now specify that SFP values should
not exceed 2.5 for central systems iFan Box Products
incorporating energy recovery, and
Installation
no more than 1.8 for those without
– Suitable for internal mounting
energy recovery heating or cooling.
–O  ptions: single fan,
and run and standby fan
Standards
–A  erodynamic tested to
DIN24163 or DS848 Part 1
–A  coustic tested to
For introductory key details of
DIN45635 or DS848 Part 2
Fläkt Woods fan ranges, including
– CE-marked
standard features and options,
see pages 16-21. Motors
– IP44 or higher rated motor
For assistance with identifying
protection
precisely the right fan solution
for your specific projects, visit
http://fanselector.flaktwoods.com

12 13
Energy efficiency

Intelligent control – matching need

Commissioning iFan units


Mechanical ventilation
iFan integral Commissioning is fast and simple.
should only be provided Each system features plug and play low
control specifications
when it is actually required voltage sensor and switch connectors,
The intelligent controls that are and a plug and socket connector
– delivered when demanded. integral to iFan operation include: between the ICU and iFan.
Otherwise, by definition, the Function The ICU is then programmed with the
system operation is a waste –A
 uto changeover facility maximum demand and operational
(Run & Standby mode)
of energy and resource. conditions that are to be monitored.
–D
 uty sharing This control strategy is determined by
(Run & Standby mode) the requirements of the installation
That’s why, at Fläkt Woods, we’ve –R
 un-on timer design for the building environment.
developed increasingly intelligent –S
 peed controller
technology. Systems that can take Inverter drives & Fans with
Performance
responsibility for recognising when IE2 motors: qualifying for tax
– Improved SFP values in normal
the need is there – or when system
ventilation mode breaks
requirements change – and react
–F  an operation varies in response Selecting systems and equipment
accordingly to maintain peak
to input signals: from maximum designed to reduce energy consumption
operating conditions.
to trickle or stop can save money in other ways.
The goal of this advanced Fläkt Woods
Set-Up Installation of approved
technology is simply stated: optimum
– Integration with Building inverters and fans with
performance with minimum running
Management System (BMS) IE2 motrors can
costs while providing full functionality.
if required mean Enhanced Capital
Delivering demand-controlled –R  emote monitoring availability Allowance (ECA) tax
–L  ow voltage sensors/switches breaks are available in the U K.
ventilation
While each iFan is effectively a These offset your investment against
Our iFan intelligent fan systems always
stand-alone system, it can operate taxable profits, and thereby help
deliver performance tailored to the
as part of the building control reduce payback timescale for the plant.
needs of the moment within the building
system when linked into the BMS.
space concerned – whether public,
The Intelligent Control Unit (ICU)
commercial or residential.
is at its heart, and this can
This advanced ventilation can therefore be programmed for various
help maintain a better, more comfortable environmental conditions – either via
indoor environment while reducing automatic or manual (user) control.
energy usage and running costs to
As well as receiving and acting on
the minimum necessary.
sensor inputs, the ICU incorporates
It does so using sophisticated controls an LED display for set-up, operation
that are constantly monitoring and and maintenance. This enables
reacting to changes in its operational easy monitoring of running times,
environment. fan speeds and other operational
data. It can also indicate faults
or service intervals.

14 15
­­Range key details

Axial fans

For general air movement


and special applications.

Including options for:


Emergency high temperature
smoke extraction (see page 8)
ATEX environments
Pressurisation

JM Aerofoil JM High Temperature Aerofoil JM Bifurcated Aerofoil Large JM Aerofoil

Standard features Sizes: 315mm to 1600mm Ø Sizes: 315mm to 2800mm Ø Sizes: 500mm to 1000mm Ø Sizes: up to 3550mm Ø

All fans are certified to ISO 5801 Volume flow: up to 65m3/s Volume flow: up to 210m3/s Volume flow: up to 20m3/s Volume flow: up to 370m3/s

CE marking Static pressure: up to 2150 Pa Static pressure: up to 2070 Pa Static pressure: up to 1000 Pa Static pressure: up to 3400 Pa

X-ray inspection of all cast Operating temperature range: High temperature capability: Operating temperature: High temperature capability:
impeller parts -20°C to +50°C up to 400°C for 2 hours up to 200°C – up to 250°C for 2 hours
– options up to 400°C for 2 hours
IE2 motors where applicable IE2 motors where applicable IE2 motors where applicable IE2 motors where applicable
IE2 motors where applicable
High energy efficiency: Role: General ventilation Role: Emergency ventilation/ Motor separated from air stream
reduced SFP and/or extraction hot fire smoke extraction Role: Heavy duty industrial and
Role: Exhaust/recirculation of
infrastructure applications –
Motor protection IP55 fumes/gases/hot air
higher pressure/volume
Non-overloading
Adjustable pitch impeller for
exact performance required
Low installed noise levels
High temperature capability:
up to 200°C for 2 hours for
three-phase fans only

Range options
Long and short casings
Multiple blade configurations
Inverter: speed controllable
Explosion proof/ATEX JM Multi-stage Aerofoil JM MaXfan and SuperLight Plate Axial JM Aerofoil Plate Axial
compliant versions Sizes: 315mm to 1000mm Ø MaXfan Plus Aerofoil Sizes: 315mm to 1000mm Ø Sizes: 315mm to 710mm Ø
Higher temperature operation as standard. Larger sizes are 
Sizes: 400mm to 630mm Ø Volume flow: up to 3.15m3/s
Volume flow: up to 8.8m /s 3

capability: tested to available on request


Volume flow: up to 7.2m /s
3
Static pressure: up to 560 Pa Static pressure: up to 180 Pa
BS EN 12101-3 Volume flow: up to 31.7m3/s
Static pressure: up to 1100 Pa Operating temperature range: Operating temperature range:
Static pressure: up to 2000 Pa -40°C up to +70°C
Operating temperature range: -30°C up to +70°C
Operating temperature range: -20°C to +50°C Speed controllable
Low noise
-20°C to +50°C
IE2 motors where applicable Additional option: Motor protection IP55
IE2 motors where applicable
Role: High pressure kitchen Can be installed in a variety of Overheat protection fitted as
Role: Higher pressure extract positions standard on single phase motors
development
Options: Options:
Option: Single-phase or three-phase Single-phase or three-phase
Further multi-stage fans available
for higher pressures

16 17
Range key details

Inline Fans, Box Fans and Roof Units

Compact boxed units for air


supply and extract where
space is restricted.

Standard features
Easy to install
Quiet operation
Energy efficient: DSJ - Roof Extract Unit SuperLite Roof Unit
on demand ventilation
Sizes: 200mm to 1000mm Ø Volume flow: up to 4.3m3/s
iFan box range Volume flow: up to 6.3m3/s Static pressure: up to 540 Pa
Box fans incorporating an integral Static pressure: up to 200 Pa Operating temperature range:
intelligent control unit (ICU), plus -30°C up to +70°C
Temperature capability: up to 50°C
sensors and/or switches
Robust, fibreglass casings High efficiency axial impellers
Delivering demand control
Mounting angle up to 30° Role: General ventilation and/or
ventilation – from maximum
extraction
to trickle (20%) or stop Role: General ventilation and/or
extraction Options:
Reduces ventilation energy
Speed is 100% infinitely variable using
consumption and running costs Aerofoil Impeller
auto transformers or electrical control
Options:
– Speed controller types: Electronic,
Transformer or Inverter

Centrifugal fans Centripal EU Europal


Operating temperature up to Operating temperature up to
For general air movement and 350°C in continuous use 350°C in continuous use
special applications.
High energy efficiency – over 80% High energy efficiency – over 85%
Including options for:
Sizes: 355mm to 1400mm Ø High aerodynamic range
Emergency high temperature
Volume flow: up to 40m3/s Sizes: up to 2500mm Ø
smoke extraction (see pages 8-9)
Static pressure: up to 20000 Pa Volume flow: up to 100m3/s
ATEX environments
Options: Static pressure: up to 26000 Pa
Metal and Plastic Tube Fans SingleBox EC TwinBox
Centrimaster GT – Impellers choice: 11 widths and Options:
Sizes: 100mm to 315mm Ø Sizes: 125mm to 400mm Ø Sizes: 125mm to 630 and 6 fixed geometry types
High temperature – Impellers choice: 10 widths and
Ø connection spigots –D  rive choice: direct or belt drive
Volume flow: up to 0.47m3/s Volume flow: up to 1.66m3/s (smoke extraction) capability: 4 fixed geometry types
Volume flow: up to 3.5m3/s (as standard); coupling drive (option)
Static pressure: up to 625 Pa Static pressure: up to 510 Pa 400°C for 2 hours – Impellers reinforced for particulate
– Safety switch to ISO 12499
Static pressure: up to 1250 Pa handling
Speed control as standard Operating temperature: up to 60°C Low noise
–D  rive choice: belt or coupling drive
Max operating temperature Sizes: 200mm to 1400mm Ø
Low noise Horizontal or vertical mounting
through fan: 60°C
Compact design Acoustically lined box Volume flow: up to 50m3/s
Single or twin fan (duty/standby) Standard features Range options
Low SFP values Easy maintenance Static pressure: up to 3300 Pa
options
Options: Fully assembled Drive options
Multi-functional lightweight fans for Neoprene seals on inlet/outlet Horizontal or vertical mounting
spigots Direct or belt drive (single inlet version. Motor protection IP55 Impeller choice
local or zoned general air movement Thermal and acoustic insulation Double inlet version belt drive only)
applications. Low noise at higher pressures
Impeller: backward curved
Impeller: forward curved centrifugal
18 19
We Bring Air to Life

Sales office UK
Fläkt Woods is a global leader in air management.
We specialize in the design and manufacture of a wide • Colchester VS
range of air climate and air movement solutions. Phone 01206 222 555

Our collective experience is unrivalled. • Birmingham ACS/VS


We are constantly aiming to provide systems that Phone 0121 717 4680
precisely deliver required function and performance as
well as maximum energy efficiency. • Manchester ACS/VS
Phone 0161 969 1992
SB-FR-EN-2013.10.0001

Fläkt Woods operates a policy of continuous improvement and reserves the right to supply products that may differ from
those illustrated and described in this publication. Certified dimensions can be supplied on request on receipt of order.

Fläkt Woods Limited


Axial Way, Colchester, Essex, CO4 5ZD

tel: 01206 222 555 fax: 01206 222 777 twitter: @flaktwoodsuk
email: info.uk@flaktwoods.com website: www.flaktwoods.co.uk
electronic catalogue: www.flaktwoods.com/vsecatalogue

See global website for international sales offices www.flaktwoods.com

You might also like