2 x MPP 7/14s
2 x MPP 8 /12stages
Vertical arrangement
Total volume flow at suction
(oil / water / gas) 180 000 bbl/d
Differential pressure 1100 psi at GVF 76%
Speed up to 6000 rpm
Motor Power 6000 HP
Commissioned 1999
Still in operation
can well cope with process condition
evolution
GVF changed from 77% to 95% as today
(GLR changed from 3.3 to about 20 as today)
29.05.2017<Copyright © Sulzer Pumps> | slide 7
MPP Abqaiq – Saudi Aramco – Saudi Arabia Sulzer Pumps
4 x MPP 11 / 6 stages
Total volume flow at suction
(oil / water / gas) 560 000 bbl/d
Differential pressure 535 psi at 91% GVF
Speed up to 6000 rpm
Motor Power 8850 HP
Commissioned 2000
1 x MPP 8 /14s
Total volume flow at suction
(Oil / Water / Gas) 180 000 bbl/d
GVF 95%
Differential pressure 360 psi
Speed up to 6000 rpm
Motor power 2650 HP
3000 psi design pressure
Commissioning - Dec 2012